NOTES: <br />• INSTALL OUTLETS AT FIXTURE BACK PANEL 30" A.F.F. <br />POS OUTLET WIRED TO SEPARATE ISOLATED GROUND PANEL <br />• HOLD WIRING BETWEEN FIXTURE UPRIGHTS AS ON <br />DETAIL 3/E6 <br />• WIRING RUN IN SHELVING UPRIGHTS TO RECEIVE <br />1/2" GREENFIELD OR BX SLEEVE. <br />• INSTALL THE CASH DROP BOXES IN <br />LOCATIONS AS SHOWN. <br />• LOCATE UNDERCOUNTER CASH CHANGE DRAWER AS DIMENSIONED. <br />• DRILL 2-1/2" DIAMETER HOLE IN CHECKOUT TOP AS DIMENSIONED. <br />PROVIDE BLACK GROMMET TO FIT. <br />DPC - DUPLEX POS ISOLATED GROUND OUTLET <br />DC - DUPLEX CONVENIENCE OUTLET M3" <br />FP - COMPUTER FACE PLATE BOXMO - MONEY ORDER <br />TYPICAL OUTLET <br />SPACING <br />THE ELECTRICAL REVISIONS DESCRIBED HEREIN ARE PURELY <br />INCIDENTAL TO THE RELOCATION AND/OR REPLACEMENT OF <br />PARTITIONS, EQUIPMENT AND FURNISHINGS FOR THE PROJECT. <br />IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ASCERTAIN <br />AND PROVIDE FOR ANY ADDITIONAL ENGINEERING TO <br />ACCOMPLISH THE WORK DESCRIBED; & TO DETERMINE THE <br />CONDITION OF THE EXISTING PANEL OR SUBPANEL AND <br />EXISTING DEVICES, CONDUIT, ETC. BEFORE REUSING <br />COMPONENTS OR RECONNECTING SAME TO EXISTING PANELS <br />OR SUBPANELS. NOTIFY THE ARCHITECT IF REPLACEMENT OF <br />COMPONENTS OTHER THAN THOSE SHOWN OR UPGRADING OF <br />COMPONENTS IS NECESSARY DUE TO CONDITION, <br />SERVICEABILITY OR A CHANGE OF CONNECTED LOAD. <br />NOTE: <br />VERIFY ALL EXISTING CONDITIONS IN FIELD PRIOR TO CONSTRUCTION. <br />POWER RISER IS EXISTING TO REMAIN. <br />SCOPE OF WORK <br />THE SCOPE OF ELECTRICAL WORK SHALL INCLUDE, BUT IS NOT LIMITED <br />TO THE FOLLOWING: <br />1. IDENTIFY ALL THE CIRCUITS BEING FED FROM EXISTING PANELS, <br />WHICH ARE BEING REUSED FOR RENOVATIONS IN RETAIL, AND <br />FOR THE RELOCATED POWER POLES. <br />2. ELECTRICAL CONTRACTOR TO VERIFY ALL EXISTING <br />CONDITIONS PRIOR TO BID & INSTALLATION. INFORM ENGINEER <br />OF RECORD OF ANY DISCREPANCY BETWEEN THE DOCUMENTS <br />& THESE CONDITIONS & HE SHALL INCLUDE IN HIS BID TO <br />CORRECT THE SAME AS DIRECTED. THE ENGINEER & <br />ARCHITECT ARE NOT RESPONSIBLE FOR ANY ADDITIONAL <br />COSTS RESULTING FROM VERIFIABLE EXISTING CONDITIONS <br />DISCOVERED AFTER THE CONTRACT HAS BEEN AWARDED. <br />3. ELECTRICAL CONTRACTOR SHALL KEEP AS -GUILTS AND SUBMIT <br />TO ENGINEER OF RECORD FOR REVIEW. ALL CHANGES SHALL BE <br />FORWARDED A MINIMUM OF (2) WEEKS PRIOR TO FINAL <br />INSPECTION. ANY EXPENSES, SUCH AS REVISIONS OR <br />AS-BUILTS, NECESSARY FOR FINAL C.O. SHALL BE AT THE <br />EXPENSE OF THE OWNER. <br />NOTE: <br />CONTRACTOR TO REPAIR ALL BURNT OUT <br />LAMPS AND BALLASTS. LIGHTING TO BE <br />100% OPERATIONAL UPON LEAVING. CLEAN <br />ALL EMERGENCY LIGHTS. <br />SYMBOL LEGEND <br />MOUNTING HEIGHT IS FROM FINISHED FLOOR TO CENTERLINE OF DEVICE OR OUTLET. <br />HEIGHT <br />MAY VARY TO COINCIDE WITH BUILDING CONSTRUCTION. <br />SYMBOL <br />DESCRIPTION <br />MOUNTING <br />HEIGHT <br />DUPLEX RECEPTACLE OUTLET <br />AS NOTED <br />RECESSED CLOCK RECEPTACLE OUTLET <br />AS NOTED <br />TELEPHONE OUTLET. PROVIDE 1 - 1" C. (WITH PULLWIRE) TO 6" ABOVE <br />AS NOTED <br />SUSPENDED CEILING. REFER TO TELEPHONE WIRING DIAGRAM FOR <br />FURTHER INFORMATION. <br />a <br />DATA <br />AS NOTED <br />QJ <br />JUNCTION BOX W/ COVERPLATE - WALL MOUNTED <br />AS NOTED <br />NOTE: UNLESS OTHERWISE NOTED ALL OUTLETS & J-BOXES TO BE LOCATED 18" A.F.F. <br />COLOR OF RECEPTACLES TO BE "MITE". REVIEW ELECTRICAL NOTES TO VERIFY <br />CONDITIONS PER ELECTRICAL LEGEND. <br />ELECTRICAL LEGEND NOTES: <br />R1 RELOCATED POWER POLE AS MANUF. BY WEIDENBACH-BROWN <br />WITH ALL COMPONENTS FOR A COMPLETE AND STATIONARY <br />INSTALLATION. WIRING CHASES TO BE FLUSH MOUNTED TO TOP OF <br />GONDOLA RE: 8/E-1. PROVIDE JUNCTION BOX 6" ABOVE CEILING FOR <br />WRING CHASE CONNECTION. <br />OPROVIDE NEW DUPLEX RECEPTACLE FOR RELOCATED APEX <br />MACHINE COORDINATE EXACT LOCATION WITH FINAL CVS <br />MERCHANDISE PLAN (F-1). INTERCEPT AND EXTEND EXISTING <br />BRANCH CIRCUIT TO RELOCATED APEX MACHINE LOCATION <br />RECONNECT AS REQUIRED FOR OPERATION. <br />R3 PROVIDE NEW RECEPTACLE FOR RELOCATED PRINTER. <br />COORDINATE EXACT LOCATION WITH FINAL CVS MERCHANDISE <br />PLAN. INTERCEPT AND EXTEND EXISTING BRANCH CIRCUIT TO <br />RELOCATED PRINTER LOCATION. RECONNECT AS REQUIRED FOR <br />OPERATION. <br />R4 PROVIDE NEW RECEPTACLE FOR RELOCATED MONEYGRAM. <br />COORDINATE EXACT LOCATION WITH FINAL CVS MERCHANDISE <br />PLAN. INTERCEPT AND EXTEND EXISTING BRANCH CIRCUIT TO <br />RELOCATED MONEYGRAM LOCATION. RECONNECT AS REQUIRED <br />FOR OPERATION. <br />R5 PROVIDE NEW RECEPTACLE FOR RELOCATED DOS. COORDINATE <br />EXACT LOCATION WITH FINAL CVS MERCHANDISE PLAN. INTERCEPT <br />AND EXTEND EXISTING BRANCH CIRCUIT TO RELOCATED DOS <br />LOCATION. RECONNECT AS REQUIRED FOR OPERATION. <br />PROVIDE NEW RECEPTACLE FOR RELOCATED SCANNER. <br />R6 COORDINATE EXACT LOCATION WITH FINAL CVS MERCHANDISE <br />PLAN. INTERCEPT AND EXTEND EXISTING BRANCH CIRCUIT TO <br />RELOCATED SCANNER LOCATION. RECONNECT AS REQUIRED FOR <br />OPERATION. <br />R7 PROVIDE ONE NEMA 545R QUAD RECEPTACLE FLUSH MOUNTED @ <br />14" AFF FOR RELOCATED KPM. COORDINATE LOCATION WITH FINAL <br />CVS MERCHANDISE PLAN. EXTEND BRANCH CIRCUIT TO RELOCATED <br />KPM LOCATION. RECONNECT AS REQUIRED FOR OPERATION. <br />Rg PROVIDE ONE NEMA 5-15R QUAD RECEPTACLE MOUNTED ABOVE <br />CABINET. <br />R9 PROVIDE ONE NEMA 5-15R QUAD RECEPTACLE FLUSH MOUNTED @ <br />24" AFF TO BOTTOM OF BOX. <br />R10 PROVIDE ONE NEMA 5-15R QUAD RECEPTACLE FLUSH MOUNTED 1" <br />BELOWER COUNTER TOP. <br />R11 PROVIDE AND INSTALL GFI TOP RAIL OUTLETS AS MANUFACTURE BY <br />WIRING CHASE WITHIN GONDOLA. <br />R12 PROVIDE ONE JUNCTION BOX AT 24" AFF, WITH 1" CONDUIT WITH <br />PULL WIRE AT 12" ABOVE CEILING. <br />R13 NEW POWER POLE AS MANUF. BY WEIDENBACH-BROWN W/ ALL <br />COMPONENTS FOR A COMPLETE AND STATIONARY INSTALLATION. <br />WIRING CHASES TO BE FLUSH MOUNTED TO TOP OF GONDOLA RE: <br />8/E-1. PROVIDE JUNCTION BOX 6" ABOVE CEILING FOR WIRING CHASE <br />CONNECTION. <br />ELECTRICAL NOTES <br />1. ALL WORK SHALL BE IN ACCORDANCE WITH THE 2017 FLORIDA BUILDING CODE, SIXTH EDITION, <br />THE 2014 NATIONAL ELECTRICAL CODE AND SHALL ALSO COMPLY WITH ALL APPLICABLE RULES <br />AND REGULATIONS OF LOCAL AND STATE LAWS AND ORDINANCES. <br />2. ELECTRICAL CONTRACTOR SHALL ARRANGE FOR ALL NECESSARY PERMITS, LICENSES, UTILITY <br />COORDINATION, AND INSPECTIONS AS REQUIRED BY THE CITY, COUNTY, OR UTILITY COMPANY. <br />OWNER WILL PAY FEES. CONTRACTOR IS RESPONSIBLE FOR ALL EQUIPMENT REQUIRED BY <br />UTILITY COMPANY AND SHOULD INCLUDE NECESSARY COSTS IN BID. <br />3. CONTRACTOR SHALL MAKE A THOROUGH EXAMINATION OF THE SITE AND THE CONTRACT <br />DOCUMENTS. NO CLAIM FOR EXTRA COMPENSATION WILL BE RECOGNIZED IF DIFFICULTIES <br />ARE ENCOUNTERED WHICH AN EXAMINATION OF SITE CONDITIONS AND CONTRACT DOCUMENTS <br />PRIOR TO EXECUTING CONTRACT WOULD HAVE REVEALED. <br />4. PRIOR TO BID CONTRACTOR SHALL IMMEDIATELY NOTIFY ENGINEER OF AND DISCREPANCIES <br />WITH CONTRACT DOCUMENTS AND EXISTING SITE CONDITIONS. <br />5. CONTRACTOR SHALL VERIFY NAMEPLATE DATA AND BREAKER SIZES FOR ALL EQUIPMENT <br />PRIOR TO PURCHASE. <br />GROUNDING: <br />1. THE INTERIOR ELECTRICAL SYSTEM SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS <br />REQUIRED BY THE NATIONAL ELECTRICAL CODE. ALL METALLIC RACEWAYS SHALL BE <br />MECHANICALLY AND ELECTRICALLY SECURE AT ALL JOINTS AND AT ALL BOXES, CABINETS, <br />FITTINGS AND EQUIPMENT. <br />2. PER ARTICLE 250.50 GROUNDING ELECTRODE SYSTEM, THE CONTRACTOR IS TO UTILIZE ALL OF <br />THE AVAILABLE ELECTRODES BONDED TOGETHER TO FORM A RELIABLE SYSTEM. ELECTRODES <br />INCLUDE: METAL UNDERGROUND WATER PIPE, METAL FRAME OF BUILDING, CONCRETE <br />ENCASED ELECTRODE, GROUND RING, ROD & PIPE ELECTRODES AND PLATE ELECTRODES. AT <br />A MINIMUM ONE OF THE PRESCRIBED ELECTRODES MUST BE UTILIZED IN ADDITION TO THE <br />METAL UNDERGROUND WATER PIPE. <br />OUTLET BOXES / DEVICES: <br />1. OUTLET SHALL BE GRAY WITH STAINLESS STEEL COVER PLATE. <br />2. ALL OUTLET BOXES SHALL BE RIGIDLY MOUNTED AND SHALL BE EQUIPPED WITH SUITABLE <br />SCREW FASTENED COVERS. OPEN KNOCKOUTS OR HOLES IN BOXES SHALL BE PLUGGED WITH <br />SUITABLE BLANKING DEVICE. <br />3. OUTLET BOXES LOCATED ABOVE CEILING SHALL BE LEGIBLY IDENTIFIED WITH BRANCH CIRCUIT <br />NUMBER OF CIRCUIT TERMINATED WITHIN BY MEANS OF BLACK PERMANENT MARKER. <br />SWITCHGEAR: <br />1. PANELBOARDS SHALL BE MANUFACTURED BY SQUARE 'D' COMPANY, AND BE NQOD TYPE. <br />FURNISH WITH COPPER BUS BARS, COPPER EQUIPMENT GROUND BUS AND BOLT -ON CIRCUIT <br />BREAKERS. APPROVED EQUALS: GENERAL ELECTRIC AND SIEMENS. <br />2. DISCONNECT SWITCHES SHALL BE HEAVY-DUTY TYPE AND MANUFACTURED BY SQUARED' <br />COMPANY. FUSES SHALL BE DUAL ELEMENT, CARTRIDGE TYPE, FUSES SHALL BE BY ONE <br />MANUFACTURER: BUSSMAN "FUSETRON" OR CHASE-SHAWMUT'TRONIC". <br />3. INSTALL ENGRAVED PLASTIC -LAMINATE LABELS ON EACH MAJOR UNIT OF ELECTRICAL <br />EQUIPMENT IDENTIFYING PANELBOARD NAME OR EQUIPMENT SERVING. EXAMPLES ARE, <br />PANELBOARDS AND DISCONNECT SWITCHES, MOTOR STARTERS, I.E. LABELS SHALL BE 1/16" <br />THICK BLACK PLASTIC LAMINATE WITH 3/8" WHITE CORE PLIE LETTERS. <br />4. PANELBOARD DIRECTORY CARDS SHALL BE TYPEWRITTEN WITH ACCURATE AND CURRENT <br />INFORMATION BY THE CONTRACTOR AT THE END OF CONSTRUCTION. <br />LIGHTING FIXTURES: <br />1. THE CONTRACTOR SHALL FURNISH AND INSTALL COMPLETE IN ALL RESPECTS ALL LIGHTING <br />FIXTURES LISTED IN THE FIXTURE SCHEDULE OR SHOWN ON THE PLANS. <br />Cf]► <br />2. THE CONTRACTOR SHALL SUBMIT CATALOG CUTS OF ALL THE FIXTURES TO THE <br />ARCHITECTIOWNER AND SHALL NOT PURCHASE UNTIL APPROVAL IS RECIEVED. <br />3. BALLASTS FOR FLUORESCENT LAMPS SHALL BE ELECTRONIC MANUFACTURED BY " ORSAM <br />SYLVANIA" OR EQUAL. ALL BALLASTS FOR FLUORESCENT FIXTURES SHALL BE INDIVIDUALLY <br />FUSED. FUSES SHALL BE INSTALLED ON THE LINE SIDE OF THE BALLAST. <br />4. FLUORESCENT LAMPS SHALL BE RAPID START, T8/32 WATT, 3500K. ALL LAMPS SHALL BE AS <br />MANUFACTURED BY SYLVANIA OR EQUAL. <br />5. ALL FIXTURES SHALL BE PROPERLY AND CAREFULLY SUPPORTED AND ALIGNED, AND THE <br />CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY STEEL SHAPES, ETC., FOR <br />SUPPORT OF FIXTURES AS REQUIRED AND DETAILED ON THE DRAWINGS. PROVIDE JUNCTION <br />BOX STEM MOUNTED FROM DECK TO SUPPORT ALL CEILING MOUNTED EXIT LIGHTS. <br />6. LIGHTING FIXTURES SHALL BE CLEAN AND LAMPED WITH NEW LAMPS AT THE TIME OF FINAL <br />INSPECTION. <br />7. COORDINATE ALL LOCATIONS OF LIGHTING FIXTURES WITH ARCHITECTURAL DRAWINGS. <br />WIRE/RACEWAY: <br />1. ALL CONDUCTORS SHALL BE COPPER, INSULATION SHALL BE DUAL TYPE THHN.THWN 75°C (167°F) <br />FOR DRY, DAMP AND WET LOCATIONS. CONDUCTOR INSULATION WITH SINGLE TYPE MARKING <br />THHN 90-C (194"F) MAY BE USED FOR DRY LOCATIONS ONLY. ALL CONDUCTORS SHALL BE <br />COLOR CODED AS REQUIRED BY NEC AND FURTHER IDENTIFIED AND CODED AS SPECIFIED <br />HEREINAFTER. COLOR CODING SHALL BE BY MEANS OF COLORED INSULATING MATERIAL, <br />SUITABLE COLORED, PERMANENT, NON -AGING INSULATING TAPE APPLIED TO CONDUCTORS AT <br />EACH CABINET OR JUNCTION POINT. THE COLOR CODING SHALL BE ACCOMPLISHED AS THE <br />CONDUCTORS ARE INSTALLED. THE FOLLOWING SYSTEMS OF COLOR CODING SHALL BE <br />STRICTLY ADHERED TO: <br />A) GROUND LEADS: GREEN <br />B) 1201208 VOLT UNGROUNDED PHASE WIRES: <br />PHASE A: BLACK <br />PHASE B: RED <br />PHASE C: BLUE <br />NEUTRAL: WHITE <br />2. THE COLOR CODE ASSIGNED TO EACH PHASE WIRE SHALL BE CONSISTENTLY FOLLOWED <br />THROUGHOUT. <br />3. UNLESS OTHERWISE INDICATED, ALL BRANCH CIRCUIT CONDUCTORS SHALL BE NO. 12 AWG. <br />ANY BRANCH CIRCUIT RUN OVER 75 FEET IN LENGTH. MEASURING ONE WAY FROM THE FIRST <br />OUTLET OF THE CIRCUIT TO THE PANEL, SHALL BE NO 10. AWG. FOR THE ENTIRE CIRCUIT. <br />4. UNLESS OTHERWISE NOTED ALL CONDUCTORS SHALL BE RUN IN THIN WALL CONDUIT AND THIN <br />WALL CONDUIT SHALL BE UNDERWRITERS' APPROVED GALVANIZED ELECTRICAL METALLIC <br />TUBING, ZINC OR CADMIUM PLATED. CONDUITS RUN UNDERGROUND SHALL BE SCHEDULE 40 <br />PVC. <br />5. COMBINING OF CIRCUITS IN SAME RACEWAY FOR HOMERUNS PERMITTED BUT LIMITED TO THREE <br />(3) CIRCUITS PER NEUTRAL AND MUST CONTAIN GROUND. <br />6. ALL RACEWAYS SHALL BE PROPERLY ALIGNED, GROUPED AND SUPPORTED BY MECHANICAL <br />TYPE 'CADDY CLIPS AT INTERVALS NOT EXCEEDING 8 FEET. EXISTING RACEWAYS TO REMAIN <br />SHALL BE RESUPPORTED WHERE RACEWAY SUPPORTS EXCEED 8 FEET. <br />7. ALL RACEWAYS WITH NO. 10 OR 12 AWG PHASE CONDUCTORS FOR RECEPTACLES, LIGHTING <br />FIXTURES AND SIMILAR CIRCUITS SHALL BE PROVIDED WITH A PARITY SIZED GREEN EQUIPMENT <br />GROUND CONDUCTOR. INCLUDING WALL SWITCHES AND FLEXIBLE CONDUIT TO LIGHT FIXTURES. <br />EQUIPMENT GROUND CONDUCTOR SIZES FOR CIRCUITS WITH PHASE CONDUCTORS LARGER <br />THAN NO. 12 AWG. ARE INDICATED ON DRAWINGS. GROUND CONDUCTORS SHALL BE <br />CONNECTED TO GROUND BUSS IN PANELBOARDS. <br />8. RACEWAY PENETRATIONS OF FIRE RATED WALLS AND/OR FLOORS SHALL BE SEALED TO <br />MAINTAIN INTEGRITY OF CONSTRUCTION. ALL PRODUCTS, MATERIALS AND METHODS OF <br />INSTALLATION SHALL BE UL APPROVED AND MEET NFPA. <br />9. CONDUIT RUNS SHOWN ARE DIAGRAMMATIC IN NATURE. CONTRACTOR IS RESPONSIBLE FOR <br />SIZING AND LOCATING ALL PULLBOXES PER LOCAL AND NATIONAL ELECTRICAL CODES. ALL <br />PULLBOXES SHALL REMAIN ACCESSIBLE AND LOCATIONS COORDINATED WITH ALL OTHER <br />TRADES. <br />PAN EL <br />(EXISTING) <br />P <br />CIRCUIT BREAKER TYPE <br />AIC RATING: 22,000 A <br />120/208 V., 3 PH., 3W <br />100A. MAIN LUGS ONLY <br />SURFACE MOUNTED - NEMA 1 <br />CKT. <br />NO. <br />NO. OF <br />POLES <br />TRIP <br />AMPS <br />VOLT <br />AMPS <br />LOAD <br />AO <br />BO <br />CO <br />CKT. <br />NO. <br />NO. OF <br />POLES <br />TRIP <br />AMPS <br />VOLT <br />AMPS <br />LOAD <br />1 <br />1 <br />20 <br />- <br />SPARE (E) <br />1000 <br />2 <br />1 <br />20 <br />1000 <br />REC PHOTO EXPRESS (E) <br />3 <br />1 <br />20 <br />- <br />SPARE (E) <br />1500 <br />4 <br />1 <br />20 <br />1500 <br />OFFICE SERVER <br />(E) <br />5 <br />1 <br />20 <br />1500 <br />EXISTING EQUIP. (E) <br />2500 <br />6 <br />1 <br />20 <br />1000 <br />REC PHOTO EXPRESS (E) <br />7 <br />1 <br />20 <br />1500 <br />EXISTING EQUIP. (E) <br />3000 <br />8 <br />1 <br />20 <br />1500 <br />OFFICE RECEPT. <br />(E) <br />9 <br />2 <br />30 <br />2000 <br />PROCESSOR (E) <br />1000 <br />10 <br />1 <br />20 <br />- <br />SPARE <br />(E) <br />11 <br />30 <br />- <br />PROCESSOR (E) <br />2500 <br />12 <br />1 <br />20 <br />1500 <br />POWER POLE <br />(E) <br />13 <br />1 <br />20 <br />500 <br />PLUGMOLD (E) <br />2000 <br />14 <br />1 <br />20 <br />1500 <br />POWER POLE <br />(E) <br />15 <br />1 <br />20 <br />500 <br />PLUGMOLD (E) <br />2000 <br />16 <br />1 <br />20 <br />1500 <br />POWER POLE <br />(E) <br />17 <br />1 <br />20 <br />1000 <br />REC: CASH WRAP (E) <br />2500 <br />18 <br />1 <br />20 <br />1500 <br />POWER POLE <br />(E) <br />19 <br />1 <br />20 <br />1000 <br />REC: CASH WRAP (E) <br />2500 <br />20 <br />1 <br />20 <br />1500 <br />EXISTING EQUIPMENT(E) <br />21 <br />1 <br />40 <br />1500 <br />PRINTER (E) <br />2000 <br />22 <br />1 <br />20 <br />500 <br />PLUGMOLD <br />(E) <br />23 <br />1 <br />40 <br />1500 <br />PRINTER (E) <br />1500 <br />24 <br />1 <br />20 <br />- <br />SPARE <br />(E) <br />25 <br />1 <br />20 <br />- <br />SPARE (E) <br />- <br />1 <br />26 <br />1 <br />20 <br />- <br />SPARE <br />(E) <br />27 <br />1 <br />20 <br />- <br />SPARE (E) <br />- <br />28 <br />1 <br />20 <br />- <br />SPARE <br />(E) <br />29 <br />1 <br />20 <br />- <br />SPARE (E) <br />- <br />30 <br />1 <br />20 <br />- <br />SPARE <br />(E) <br />31 <br />1 <br />20 <br />500 <br />CABINET RECPT. (E) <br />2000 <br />32 <br />1 <br />20 <br />1500 <br />PEPSI FLM <br />(N) <br />33 <br />1 <br />20 <br />1500 <br />POWER POLE (N) <br />1500 <br />34 <br />1 <br />20 <br />- <br />SPARE <br />(E) <br />35 <br />1 <br />20 <br />- <br />SPARE (E) <br />- <br />36 <br />1 <br />20 <br />- <br />SPARE <br />(E) <br />37 <br />1 <br />20 <br />- <br />SPARE (E) <br />- <br />38 <br />1 <br />20 <br />- <br />SPARE <br />(E) <br />39 <br />1 <br />20 <br />- <br />SPARE (E) <br />- <br />40 <br />1 <br />20 <br />- <br />SPARE <br />(E) <br />41 <br />1 1 <br />20 <br />- <br />SPARE (E) <br />- <br />42 <br />1 <br />20 <br />- <br />SPARE <br />(E) <br />LIGHTING <br />RECEPTACLES <br />RECEPTACLES <br />HVAC <br />EQUIPMENT <br />SUBFEED <br />LARGEST MOTOR <br />TOTAL CONNECTED VA <br />0.0 KVA X 1.25 DEMAND FACTOR <br />10.0 KVA X 1.00 DEMAND FACTOR <br />3.5 KVA X 0.50 DEMAND FACTOR <br />0.0 KVA X 1.00 DEMAND FACTOR <br />13.2 KVA X 1.00 DEMAND FACTOR <br />0.0 KVA X 1.00 DEMAND FACTOR <br />2.2 KVA X 1.00 DEMAND FACTOR <br />10500 8000 9000 <br />0.0 KVA DEMAND LOAD <br />10.0 KVA DEMAND LOAD <br />1.8 KVA DEMAND LOAD <br />0.0 KVA DEMAND LOAD <br />13.2 KVA DEMAND LOAD <br />0.0 KVA DEMAND LOAD <br />2.2 KVA DEMAND LOAD <br />PANEL CALCULATION <br />27.20 <br />TIMES 1000 <br />DIVIDED BY DIVIDED BY 1.7 1.732 <br />AMPS <br />75.50 <br />NOTES: 1 <br />2. <br />OR VERIFYDATA ON ALL EQUIPMENT PRIOR TO SELECTING CIRCUIT <br />E CONTRACTOR <br />BRCONDUITS. <br />CONTRACTOR TO VERIFY OTHER OWNER REQUIRED LOADS I.R. WELLS, BLDGS, SITE LIGHTING, ETC... <br />PRIOR TO BIDDING AND PURCHASE OF ELECTRICAL COMPONENTS. <br />37943 EI W BLVD. <br />ZEPHYRHILLS, FL 33542 <br />PRDJ=TM FM AM <br />DEAL TYPES NIA <br />06A z I II =xv <br />I� <br />Robert Reid Wedding. <br />Architects & Planners, AIA, Inc. <br />4112 Cypress Street - Tampa, Florida 33607 - 813-879-6996 <br />612 South Military Trail - Deerfield Beech, Florida 33442 - 954.492-9980 <br />Florida License rs: ArchitectunA lnterior Design: AA-0001123 - Engineering: 00002655 <br />COMLTW.. <br />ENGINUITY <br />CONSULTING ENGINEERS, LLC <br />CA NO. 32146 <br />5121 EHRLICH RD, SUITE 104E <br />TAMPA, FLORIDA 33624 <br />813.358.5550 <br />DEVELOPER <br />MICHAEL AYERS, P.E. <br />FL NO 36319 <br />REVISIONS: <br />1 REVISION 06.12.2018 <br />DRAWING BY: GW <br />DATE: 03/05/2018 <br />JOB NUMBER: 18027 <br />TITLE: <br />ELECTRICAL NOTES, <br />SCHEDULES, & LEGEND <br />SHEET NUMBER: <br />E1 <br />COMMENTS: <br />TAKE OFF / BID SET <br />