3 � <br />j <br />i <br />s <br />€ <br />X <br />i <br />I <br />j4} <br />i <br />i <br />n Level 1 - Mechanical Plan <br />U 3/8" = 1'-0" <br />z l v,+,w, <br />N <br />a- <br />8"o <br />12"o <br />16"x1 <br />{ <br />3 <br />I4 <br />------------- <br />�3 <br />'u <br />1 <br />0 <br />x <br />N <br />0 <br />X <br />co <br />N <br />MECHANICAL NOTES: <br />1. <br />DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND <br />WORK INCLUDED IN THE CONTRACT. DRAWINGS ARE NOT TO BE SCALED. THE DRAWINGS AND <br />DETAILS SHALL BE EXAMINED FOR EXACT LOCATION OF FIXTURES AND EQUIPMENT. ANYTHING <br />MENTIONED IN THE SPECIFICATION WILL BE INTERPRETED AS BEING IN BOTH. ANY CONFLICT <br />SHALL BE IMMEDIATELY TO BROUGHT TO THE ATTENTION OF THE OWNER OR ENGINEER <br />BEFORE PROCEEDING WITH THE WORK. <br />2. <br />THE HVAC CONTRACTOR SHALL FURNISH ALL EQUIPMENT, MATERIAL, LABOR, ETC. NECESSARY <br />TO PROVIDE A COMPLETE, WORKABLE AND CODE APPROVED AIR CONDITIONING SYSTEM. ALL <br />WORK SHALL BE DONE ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS, LOCAL, STATE <br />AND NATIONAL CODES. <br />3. <br />THE HVAC CONTRACTOR SHALL GIVE ALL NECESSARY NOTICES, OBTAIN ALL PERMITS AND PAY <br />ALL GOVERNMENT FEES, SALES TAXES AND OTHER COSTS IN CONNECTION WITH HIS WORK; <br />FILE ALL NECESSARY APPROVALS OF ALL GOVERNMENTAL DEPARTMENTS HAVING <br />JURISDICTION; OBTAIN ALL REQUIRED CERTIFICATES OF INSPECTION FOR HIS WORK; AND <br />DELIVER TO THE OWNER THE SAME CERTIFICATES BEFORE REQUEST FOR ACCEPTANCE AND <br />FINAL PAYMENT FOR THE WORK. <br />4. <br />THE HVAC CONTRACTOR SHALL GIVE FULL COOPERATION TO OTHER TRADES AND SHALL <br />FURNISH IN WRITING TO THE ARCHITECT, ANY INFORMATION NECESSARY TO PERMIT THE WORK <br />OF ALL TRADES TO BE INSTALLED SATISFACTORILY AND WITH THE LEAST POSSIBLE <br />INTERFERENCE OR DELAY. <br />5. <br />THEE CONTRACTOR SHALL EXAMINE THE DUCTWORK ROUTING ON THESE PLANS WITH <br />RESPECT TO THE FINAL STRUCTURAL TRUSS ARRANGEMENT. THE CONTRACTOR SHALL <br />PROVIDE SHOP DRAWINGS INDICATING THE FINAL DUCT ROUTING FOR REVIEW BY THE <br />ARCHITECT AND ENGINEER PRIOR TO INSTALLING ANY MATERIAL ON THIS PROJECT. THIS MAY <br />REQUIRE DUCTWORK ROUTING WITHIN STRUCTURAL TRUSS SPACE AND SHALL BE <br />COORDINATED WITH FINAL STRUCTURAL ARRANGEMENTS. THE SHOP DRAWING SHALL BE OF <br />THE SAME SCALE AS THE ORIGINAL CONTRACT DOCUMENT. FINAL DUCT ROUTING SHALL BE <br />PROVIDED WITHOUT ADDITIONAL COST TO THE PROJECT. <br />6. <br />CLEARANCES AROUND APPLIANCES TO ELEMENTS OF PERMANENT CONSTRUCTION, INCLUDING <br />OTHER INSTALLED EQUIPMENT AND APPLIANCES, SHALL BE SUFFICIENT TO ALLOW INSPECTION, <br />SERVICE, REPAIR OR REPLACEMENT WITHOUT REMOVING SUCH ELEMENTS OF PERMANENT <br />CONSTRUCTION. ROOF MOUNTED EQUIPMENT LOCATED WITHIN 10 FEET OF A ROOF EDGE <br />SHALL BE PROVIDED WITH GUARDS HAVING A HEIGHT OF NO LESS THAN 42 INCHES. <br />7. <br />MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER <br />OPERATION AND CONSISTENT WITH GOOD WORKMANSHIP, SHALL BE INCLUDED IN THE <br />ESTIMATE, THE SAME AS IF SHOWN ON DRAWINGS. <br />8. <br />ALL DUCT WORK IS TO BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH SMACNA <br />MANUALS AND THE FOLLOWING SCHEDULE: <br />A. RECTANGULAR DUCTS: GALVANIZED SHEET METAL WITH EXTERNAL DUCT WRAP. <br />SEE RECTANGULAR DUCT SCHEDULE FOR DUCT GAGE. ALL DUCTS WITH 24 INCH <br />WIDTH OR GRATER SHALL HAVE MECHANICAL FASTENERS AT A MAXIMUM OF 18 <br />INCH CENTERS. DUCTBOARD SUCH AS "SUPERDUCT" AS MANUFACTURED BY <br />JOHNS MANVILLE, INTERNALLY LINED FIBERBOARD MAY BE SUBMITTED AS AN <br />ALTERNATE. THE DUCTBOARD JOINTS SHALL BE TAPED AND MASTICED. <br />B. RIGID ROUND DUCTS: GALVANIZED SHEET METAL WITH EXTERNAL INSULATION. <br />C. FLEXIBLE ROUND DUCTS: FLEXIBLE, WIRE REINFORCED DUCT WITH EXTERNAL <br />INSULATION WITH VAPOR BARRIER AND FOIL FACED. FLEX MUST BE STRETCHED <br />TO REMOVE ACCORDION EFFECT. FLEX DUCT LENGTH SHALL NOT EXCEED 7 FT <br />LENGTH. <br />D. FRESH AIR DUCT: GALVANIZED SHEET METAL WITH EXTERNAL DUCT WRAP IN <br />CONDITIONED SPACES. <br />9. <br />MINIMUM INSULATION RESISTANCE FOR DUCTWORK SHALL BE AS FOLLOW: <br />A. CONDITIONED SPACES - R-4.2 <br />B. UNCONDITIONED SPACES - R-6.0 <br />10. <br />ALL DUCT SIZES INDICATE "FREE AREA" DIMENSIONS, ALL TAKE -OFFS AND DIVIDED FLOWS <br />SHALL HAVE VOLUME DAMPERS. PROVIDE SPIN -IN COLLARS WITH INTEGRAL SCOOPS AND <br />DAMPERS FOR ALL BRANCH TAKE -OFFS. PROVIDE TURNING VANES FOR ALL ELBOWS AND <br />SPLITTERS. <br />11. <br />FURNISH AND INSTALL ALL GRILLES, DIFFUSERS AND REGISTERS OF THE TYPE AND AT THE <br />LOCATIONS SHOWN ON THE PLANS. ALL GRILLES, DIFFUSERS, LOUVERS, ETC. SHALL BE <br />EXTRUDED ALUMINUM WITH BAKED WHITE ENAMEL FINISH. SPONGE RUBBER GASKETS SHALL <br />BE INSTALLED BEHIND FLANGES OF ALL GRILLES, DIFFUSERS AND REGISTERS TO PREVENT <br />LEAKAGE AND STREAKING. ALL GRILLES, DIFFUSERS, REGISTERS, ETC. SHALL BE INSTALLED IN <br />ACCORDANCE WITH FACTORY DETAILS. <br />12. <br />FACTORY MADE OPPOSED BLADE DAMPERS WITH FRONT ACCESSIBLE OPERATOR AND DUCT <br />RING SHALL BE FURNISHED FOR EACH NEW DIFFUSER. <br />13. <br />PROVIDE FLEXIBLE CONNECTORS WHERE METAL DUCTWORK CONNECT TO FANS OR AIR <br />HANDLERS. <br />14. <br />THE MECHANICAL CONTRACTOR SHALL PROVIDE FIRE DAMPER AS REQUIRED TO PENETRATE <br />FIRE RATED WALL ASSEMBLIES. DUCT ACCESS DOORS SHALL BE PROVIDED AT ALL FIRE <br />DAMPERS, SMOKE DETECTORS, AND AT ALL 25 FT DUCT INTERVALS WITHOUT DIFFUSER <br />OPENINGS. ACCESS DOORS SHALL BE CLEARLY VISIBLE THROUGH DUCT INSULATION AND SHALL <br />BE CONSTRUCTED AS SHOWN IN SMACNA LOW PRESSURE STANDARDS. DOORS SHALL BE THE <br />SAME GAUGE AND MATERIAL AS THE DUCT. MINIMUM SIZE OF ALL ACCESS SHALL BE 20X12 <br />EXCEPT WHERE DUCT IS LESS THAN 14 INCHES, IN WHICH CASE ONE DIMENSION SHALL BE 20 <br />INCHES AND THE OTHER 2 INCHES LESS THAN THE DUCT WIDTH. <br />15. <br />WHERE IT IS POSSIBLE TO SEE THROUGH DIFFUSERS, GRILLES OR REGISTERS TO DUCTWORK, <br />LIGHT COLOR INSULATION OR PLENUMS, THE INTERIOR DUCTWORK OR PLENUM SHALL BE <br />PAINTED FLAT BLACK. <br />16. <br />THE REFRIGERANT LINE SHALL BE SIZED IN ACCORDANCE WITH THE MANUFACTURERS <br />INSTALLATION INSTRUCTIONS. REFRIGERANT LINE INSULATION SHALL BE 1 INCH MINIMUM IN <br />UNCONDITIONED ATTIC AREAS. COVER INSULATION AT BUILDING EXTERIOR WITH UV RESISTANT <br />COATING. INSTALL INSULATION SECTIONS WITH COMPRESSION GLUE AT BUTT JOINTS. <br />17. <br />THE HVAC CONTRACTOR IS RESPONSIBLE FOR ALL CONTROLS AND CONTROL WIRING. SEE <br />SEQUENCE OF OPERATION. <br />18. <br />ALL AIR HANDLERS TO HAVE SLOPED DRAIN PANS. <br />19. <br />THE HVAC CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL CONDENSATE PIPING. CONDENSATE <br />PIPING SHALL BE CONSTRUCTED OF PVC PIPING. CONDENSATE LINES LOCATED IN <br />UNCONDITIONED SPACES SHALL BE INSULATED. <br />20. <br />WORK SHALL INCLUDE TESTING AND BALANCING OF THE HVAC SYSTEM. THE CONTRACTOR <br />SHALL SUBMIT COPIES OF TEST AND BALANCE REPORTS SHOWING RESULTS OF BALANCING OF <br />AIR QUANTITIES TO PLAN REQUIREMENTS. MAKE ALL ADJUSTMENTS REQUIRED TO PROVIDE <br />+/-10% DESIGN AIR FLOW. <br />21. <br />WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND <br />MAINTENANCE INSTRUCTIONS, WALK THROUGH WITH MAINTENANCE CREW, AND ONE YEAR <br />GRANTEE, COMMENCING ON DATE OF ACCEPTANCE BY OWNER. <br />p _ 22. <br />THE VENTILATION RATE PROCEDURE OF FLORIDA BUILDING CODE - 2017 MECHANICAL HAS BEEN <br />USED TO DETERMINE THE AMOUNT OF OUTSIDE AIR FOR THIS SPACE. ANY CHANGE IN SPACE <br />USE, CONTAMINANTS, OR OPERATION MAY REQUIRE A REEVALUATION OF THE DESIGN AND <br />IMPLEMENTATION OF NEEDED CHANGES. <br />23. <br />THERMOSTATS AND HUMIDISTAT SHALL BE MOUNTED AT 4 FEET ABOVE THE FLOOR. <br />24. <br />EACH CONDITIONED SPACE SHALL BE PROVIDED WITH A MEANS OF RETURNING AIR TO THE AHU <br />AS INDICATED ON THIS PLAN. WHERE NOT SHOWN, ACCEPTABLE METHODS INCLUDE: <br />A. RETURN TRANSFER DUCT SHALL BE A 1.5 TIME THE CROSS SECTIONAL AREA OF <br />THE SUPPLY DUCT ENTERING THE ROOM. <br />B. TRANSFER GRILLS SHALL USE 50 SQUARE INCHES (OF GRILLE AREA) TO 100 CFM <br />(OF SUPPLY AIR) FOR SIZING THROUGH THE WALL TRANSFER GRILLES. <br />C. BOTH A. AND B. SHALL USE UNDERCUT ENTRY DOORS (MIN. 1 INCH) <br />25. <br />ALL EQUIPMENT EXTERIOR TO THE BUILDING SHALL BE SECURED TO WITHSTAND 150MPH <br />WINDS, <br />26. <br />MECHANICAL EQUIPMENT IDENTIFICATION: PROVIDE ENGRAVED PLASTIC LAMINATE SIGN, <br />PLASTIC EQUIPMENT MARKER, OR STENCILED SINGES FOR THE FOLLOWING EQUIPMENT AND <br />OPERATIONAL DEVICES, FIRE HAND LETTERING SHALL NOT BE ACCEPTED. <br />A. AIR HANDLERS, CONDITIONERS AND SIMILAR MOTOR DRIVEN UNITS LETTERING <br />SIZE SHALL BE 1 INCH HEIGHT (MINIMUM) AS NEEDED FOR PROPER <br />IDENTIFICATION TEXT FOR EQUIPMENT IDENTIFICATION SIGNS SHALL INCLUDE, <br />UNIT NAME AND NUMBER AS PROVIDED IN THE CONTRACT DRAWINGS (IE: AHU-1, <br />CU-1, HEX-1 ETC.). IF NOT IDENTIFIED BY THE MANUFACTURER, THE CONTRACTOR <br />SHALL PROVIDE A SIGN TO INDICATE THE LOCATION OF FILTER ACCESS ON <br />AHU'S. <br />W. 15ARNETT ENTERPRISE% INC. <br />0.W. : <br />TAMf-A, FL. 33603 <br />P.E. 25516 <br />Q <br />Z <br />w >.0 <br />0 Z U) <br />Uww0w <br />LU J <br />Qz Q � <br />ZU <br />}�1J1-a <br />0 <br />wo�aw <br />W <br />ow�0> <br />w 00 C0 0 <br />W W F_ <br />Q=QZO <br />IY 0 0- a Cl) <br />a�2cf)- <br />ZU10=~w <br />U Z)U <br />LU0z .0Z <br />00 Z - to 0 <br />1: 0 <0 C/) <br />ZLU OwC��� <br />H <br />Q 5; < 0 <br />J aw�o--- <br />0 (AaU2LM <br />2 S (.5 5 2 Q <br />❑ U)<E0 J <br />Z <br />U_ <br />0 <br />o <br />0� <br />�E <br />O <br />LLI <br />Q <br />� <br />< <br />Q <br />O <br />2 <br />> <br />w <br />O <br />BU <br />w <br />G7 <br />X <br />z d <br />U <br />(> <br />O <br />CO 0 <br />Z <br />2 <br />`1 <br />LLI ch <br />��Ln(D <br />Z <br />J <br />U� <br />p <br />O <br />D <br />o <br />2 <br />o <br />rQ <br />oo = <br />Y <br />U <br />06 <br />C0 <br />U 2 <br />Z <br />Jw <br />Jw <br />0 <br />Z J <br />a <br />C� <br />v <br />W <br />❑ W <br />H <br />2= <br />2 Q <br />No. Description Date <br />SOUTH LAKE <br />PHARMACY <br />MECHANICAL <br />Project number 3810.1.18 <br />Date Issue Date <br />Drawn by HK <br />Checked by Checker <br />M 101 <br />Scale 3/8" = 1'-0" <br />a <br />0 <br />M <br />CO <br />0 <br />00 <br />N <br />161 <br />THESE DOCUMENTS AND THEIR CONTENTS ARE THE PROPERTY OF HKH DESIGN LLC. AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT THE WRITTEN CONSENT OF HKH DESIGN LLC. <br />DO <br />