— — -- ] <br />OIELECTRICAL POWER FLAN - DEMOLITION <br />SCALE: 3/32" a I'-011 <br />KEYED NOTES <br />(D EXISTING DEVICE TO BE REMOVED. REMOVE 5ACK5OX AND ALL <br />CONDUIT AND WIRING BACK TO NEAREST UPSTREAM JUNCTION BOX. <br />EXISTING VOICE / DATA DEVICE TO BE REMOVED. REMOVE 5ACK50X <br />AND ALL CONDUIT AND WIRING BACK TO TERMINATION EQUIPMENT IN <br />EXISTING COMPUTER ROOM. <br />EXISTING DEVICE TO BE REMOVED. REMOVE 5ACK50X AND ALL <br />CONDUIT AND WIRING TO NEAREST UPSTREAM JUNCTION BOX. PATCH <br />AND REFINISH WALL AS REQUIRED. <br />\ 14\ REMOVE EXISTING BRANCH CIRCUIT WIRING SERVING WATER HEATER <br />BACK TO PANEL OF ORIGIN. REMOVE ALL ASSOCIATED CONDUIT, <br />BACK BOXES AND DISCONNECTING DEVICES. <br />O REMOVE ALL DEVICES AND WIRING MOUNTED IN NURSE STATION <br />CASEWORK CUT CONDUITS FLUSH WITH FLOOR AND CAP. <br />REMOVE EXISTING NURSE CALL SYSTEM MASTER AND ALL <br />ASSOCIATED WIRING BACK TO SYSTEM CONTROL PANEL LOCATED <br />IN EXISTING ELECTRICAL ROOM. <br />O REMOVE EXISTING NURSE CALL SYSTEM CONTROL PANEL AND ALL <br />ASSOCIATED SYSTEM WIRING. I <br />REMOVE EXISTING NURSE CALL SYSTEM "CODE BLUE" PUSHBUTTON <br />AND ALL ASSOCIATED WIRING BACK TO CONTROL PANEL. REUSE <br />5ACK50X FOR INSTALLATION OF NEW SYSTEM DEVICE. SEE NEW WORK <br />/c'\ REMOVE EXISTING NURSE CALL SYSTEM "STAFF ASSIST" PUSHBUTTON <br />AND ALL ASSOCIATED WIRING BACK TO CONTROL PANEL. REUSE <br />5ACK50X FOR INSTALLATION OF NEW SYSTEM DEVICE. SEE NEW WORK <br />10 REMOVE EXISTING NURSE CALL SYSTEM "DUTY STATION" AND ALL <br />ASSOCIATED WIRING BACK TO CONTROL PANEL. REUSE 5ACK50X <br />FOR INSTALLATION OF NEW SYSTEM DEVICE. SEE NEW WORK. <br />(D REMOVE EXISTING NURSE CALL SYSTEM "DOME LIGHT" AND ALL <br />ASSOCIATED WIRING BACK TO CONTROL PANEL. REUSE 5ACKE50X <br />FOR INSTALLATION OF NEW SYSTEM DEVICE. SEE NEW WORK. <br />62REMOVE EXISTING NURSE CALL SYSTEM "BEDSIDE CALL" PUSHBUTTON <br />ANi:;) ALL ASSOCIATED WIRING BACK TO CONTROL PANEL. REUSE <br />5ACK50X FOR INSTALLATION OF NEW SYSTEM DEVICE. SEE NEW WORK, <br />63-REMOVE EXISTING NURSE CALL SYSTEM "TOILET EMERGENCY" PULL - <br />CORD AND ALL ASSOCIATED WIRING BACK TO CONTROL PANEL. <br />REUSE 5ACK50X FOR INSTALLATION OF NEW SYSTEM DEVICE. SEE <br />NEW WORK. <br />ILL REMOVE EXISTING NURSE CALL SYSTEM DUTY STATION. REMOVE AL <br />CONDUIT, 5ACK5OX AND WIRING BACK TO CONTROL PANEL. <br />18 EXISTING FIRE ALARM SYSTEM SMOKE DETECTOR. REMOVE AND <br />RELOCATE. SEE NEW WORK <br />EXISTING FIRE ALARM SYSTEM DEVICE TO REMAIN. <br />EXISTING FIRE ALARM SYSTEM DEVICE. REMOVE AND RELOCATE. <br />SEE NEW WORK. <br />IS EXISTING GENERATOR REMOTE ANNUNCIATOR TO BE REMOVED. <br />REMOVE ALL ASSOCIATED CONDUIT AND WIRE BACK TO GENERATOR. <br />19 EXISTING FIRE ALARM REMOTE ANNUNCIATOR. REMOVE AND <br />RELOCATE. PREPARE EXISTING WIRING FOR EXTENSION TO NEW <br />LOCATION. SEE NEW WORK. <br />EXISTING FIRE ALARM SYSTEM REMOTE DIALER STATUS PANEL TO BE <br />REMOVED. DIALER FUNCTIONS TO BE PART OF NEW FIRE ALARM <br />SYSTEM. <br />51 EXISTING FIRE ALARM SYSTEM DIALER PANEL TO BE REMOVED. <br />DIALER FUNCTIONS TO BE PART OF NEW FIRE ALARM SYSTEM. <br />22 EXISTING A/C UNITS MOUNTED ON EXTERIOR WALL TO BE REMOVED. <br />REMOVE ALL ASSOCIATED CONDUIT, WIRING AND DISCONNECTING <br />EQUIPMENT BACK TO EXISTING A/C FANEI-50ARD ON EXTERIOR <br />EAST WALL. SEE NOTE BELOW. <br />23 THESE CONDUITS CONTAINING FIBER OPTIC AND VOICE/DATA WIRING <br />TO ADJACENT BUILDING TO REMAIN. <br />24 REMOVE AND RELOCATE EXISTING SECURITY CAMERAS. PREPARE <br />SYSTEM WIRING FOR EXTENSION TO NEW LOCATION. SEE NEW WORK — <br />EXISTING DOOR RELEASE PUSHBUTTON. REMOVE DEVICE, CONDUIT <br />AND ALL SYSTEM WIRING. <br />EXISTING EMERGENCY GENERATOR SERVING COMPUTER ROOM A/C <br />UNITS TO REMAIN. GENERATOR TO BE REUSED FOR EMERGENCY <br />BACK-UP OF NEW ROOF TOP EQUIPMENT. <br />6-7 EXISTING AUTOMATIC TRANSFER SWITCH AND DISCONNECT SERVING <br />EXISTING COMPUTER ROOM A/C UNITS. EQUIPMENT TO BE REUSED <br />FOR EMERGENCY BACK-UP OF NEW ROOF TOP EQUIPMENT. <br />28 EXISTING FANELMOARD FEEDING EXISTING COMPUTER ROOM A/C <br />UNITS TO BE REMOVED AFTER INSTALLATION OF NEW PANEL. SEE <br />NOTE BELOW. <br />29 FIELD VERIFY EXISTING DEVICES LOCATED IN WALL, SCHEDULED FOR <br />DEMOLITION. TERMINATE EXISTING BRANCH CIRCUIT WIRING ABOVE <br />CEILING. REMOVE VOICE/DATA WIRING BACK TO HEAD END AS <br />APPLICABLE. REMOVE ALL DEVICES AND RELATED RACEWAY. REFER <br />TO ARCHITECTURAL PLANS FOR EXTEND OF DEMOLITION. I <br />NOTE <br />I. COMPUTER ROOM COOLING MUST BE MAINTAINED. CONTRACTOR <br />SHALL COORDINATE ANY INTERRUPTION REQUIRED FOR THE <br />INSTALLATION OF NEW WVAC EQUIPMENT AND ASSOCIATED ELECTRICAL <br />EQUIPMENT WITH THE OWNER / IT DEPARTMENT. CONTRACTOR SHALL <br />SCHEDULE ALL NEW WOW AND DEMOLITION INVOLVING THE NEW <br />ROOFTOP WVAC, EQUIPMENT AS REQUIRED TO MINIMIZE COOLING <br />SYSTEM INTERRUPTION. <br />0\\11 I I I I//// <br />8680 <br />T '44 <br />N <br />REVISIONS <br />BY <br />VE / MER CHG5 <br />WPE <br />7m <br />E <br />Cn <br />E ti <br />Cn <br />ti <br />ai <br />rk. <br />0 <br />Uw <br />0� <br />z <br />E-0 - <br />E <br />al <br />0 <br />0 <br />u a <br />"t, In In <br />p � -0 <br />g <br />• 44 <br />ti <br />O <br />u <br />8 <br />u <br />ws�or.� <br />cc <br />0 <br />u') <br />rr) <br />0 _J <br />cn <br />LLI <br />� <br />v0 <br />� <br />< Ld <br />Lr) <br />►O -C <br />0 <br />00 <br />0 <br />IV <br />—i <br />LL- <br />Date: 12. 15. 10 <br />Scale: AS NOTED <br />Project Mgr: WHE <br />Drawn: WHE <br />Job: 09-45 <br />Sheet <br />E5 <br />Of 23 <br />Sheets <br />