Laserfiche WebLink
1 1 2 1 3 <br />Q <br />4 1 5 I 6 1 7 i 8 I 9 1 10 1 11 1 12 1 13 1 14 1 15 1 16 1 17 <br />SUPPORT CLIP FIXTURE FROM STRUCTURE. <br />#12 AWG WIRES MINIMUM. <br />SUPPORT FIXTURE PER NEC ARTICLE 410 <br />A MINIMUM OF TWO CLIPS AND ANY LOCAL SEISMIC REQUIREMENTS. <br />SHALL BE LOCATED AT <br />EACH FIXTURE <br />18 <br />19 1 20 <br />9 <br />P <br />0 <br />N <br />M <br />L <br />K <br />J <br />H <br />G <br />F <br />E <br />0 <br />C <br />B <br />V B-LINE #BA-1 SUPPORT CLIP <br />OR EQUAL <br />T-GRID <br />DWI (INLCUDECUDED <br />SUPPORT CUP BOLT WITH CLIP) <br />THROUGH TOP OF FIXTURE <br />AND SECURED BY WINGNUT WALLWASH FIXTURE <br />FIXTURE BODY <br />WEIGHT IS LESS THAN <br />10 LBS (7.7LBS). <br />WALLWASH FIXTURE SUPPORT DETAIL <br />NO SCALE <br />NORMAL <br />BALLAST <br />UNIT EQUIPMENT <br />CONNECTED IN <br />SIMILAR MANNER <br />EMERGENCY <br />BALLAST <br />SWITCH IN <br />EMERGENCY BALLAST MUST <br />ROOM OR <br />BE CONNECTED TO THE SAME <br />LIGHTING <br />CIRCUIT AS THE NORMAL <br />RELAY <br />BALLAST. <br />THIS DETAIL DOES NOT APPLY TO <br />FIXTURES WITH EMERGENCY BALLASTS <br />IN THE SALES AREA WHICH ARE ON AN <br />UNCONTROLLED CIRCUIT. CONNECT <br />EMERGENCY BALLASTS TO THE SAME <br />N H <br />CIRCUIT AS THE FIXTURE. <br />SWITCHED EMERGENCY FIXTURE SCHEMATIC <br />NOT TO SCALE <br />SUPPORT FROM FIXTURE BODY TO <br />STRUCTURE - 2 TIE WIRES PER FIXTURE AT <br />OPPOSITE CORNERS WITH 4 TWISTS PER <br />WIRE. #12 AWG WIRES MINIMUM. SUPPORT <br />FIXTURE PER NEC ARTICLE 410 AND ANY <br />LOCAL SEISMIC REQUIREMENTS.. / <br />STRUCTURE ABOVE <br />VERIFY HEIGHT <br />NOTE: <br />FIXTURE SUPPORT WIRES <br />ANCHORED TO STRUCTURE <br />OR UNITSTRUT FRAMING <br />ANCHORED TO STRUCTURE. <br />LAY -IN CEILING <br />LAY -IN FIXTURE SUPPORTED <br />INDEPENDENTLY OF LAY -IN CEILING <br />FIXTURE TO STRUCTURE <br />LAY -IN CEILING RECESSED FIXTURE SUPPORT DETAIL <br />NO SCALE <br />LIGHTING LEGEND <br />1771 Z X 4' 4-LAMP LENSED TROFFER WITH (4) T8 LAMPS. <br />E. SAM JONES ITEM # 2GT8432Al2MVOS1O LP <br />NEW FIXTURES FIXTURES <br />®2' X 4' 4-LAMP LENSED TROFFER WITH (4) T8 LAMPS, EMERGENCY EGRESS LIGHTING BATTERY PACK, <br />CONNECT TO EMERGENCY LIGHTING CIRCUIT OR LIGHTING CIRCUIT AHEAD OF ANY SWITCHING. <br />E. SAM JONES ITEM # 2GT8332Al2MV1/3EL14 LP <br />NEW FIXTURES <br />4' 1-LAMP ASYMMETRICAL STRIP FIXTURE WITH (1) T8 LAMP, MULTIVOLT BALLAST. <br />O E. SAM JONES ITEM # Z132MVOLTGEUM WITH Z8ASR48 J4 REFLECTOR <br />NEW FIXTURES <br />4' 2-LAMP INDUSTRIAL FIXTURE. <br />® E. SAM JONES ITEM # LA232MVOLT1/4GEUM <br />NEW FIXTURES <br />8' 2-LAMP INDUSTRIAL FIXTURE. <br />E. SAM JONES ITEM # TLA232MVOLT1/4GEUM <br />NEW FIXTURES <br />EXIT SIGN. WALL OR CEILING MOUNTED. CONNECT TO EMERGENCY LIGHTING CIRCUIT OR LIGHTING <br />e ® CIRCUIT AHEAD OF SWITCHING OR CONTROL. <br />E. SAM JONES ITEM # EXR LED EL M6 (NEW) <br />NEW FIXTURES FIXTURES <br />4& EMERGENCY EGRESS LIGHTING UNIT. WALL MOUNTED (T-6"). CONNECT TO LIGHTING CIRCUIT <br />AHEAD OF SWITCHING OR CONTROL. <br />E. SAM JONES ITEM # EU2 LED M12 <br />NEW FIXTURES <br />EXIT SIGN / EMERGENCY EGRESS LIGHTING COMBO UNIT. WALL OR CEILING MOUNTED. <br />CONNECT TO LIGHTING CIRCUIT AHEAD OF SWITCHING OR CONTROL. <br />`�g j' E. SAM JONES ITEM # LHQM SW3R N <br />NEW FIXTURES <br />NEMA EXTERIOR NEMA 4X EMERGENCY EGRESS LIGHTING UNIT. WALL MOUNTED 9'-01, AFF. CONNECT TO <br />4X ® EMERGENCY LIGHTING CIRCUIT OR LIGHTING CIRCUIT AHEAD OF SWITCHING OR CONTROL. <br />SEAL CONDUIT PENETRATION THROUGH WALL. <br />E. SAM JONES ITEM # INDX618 <br />NEW FIXTURES <br />MOTION DETECTOR SWITCH, RECESS MOUNT 48" AFF. SENSOR SWITCH MODEL WSD-PDT. <br />NEW SWITCHES REPLACE EXISTING SWITCHES WHERE INDICATED. <br />20A, 1-POLE DECORA SWITCH, RECESS MOUNT 48" AFF. <br />EF EXHAUST FAN (BY MECH. CONTR.). SWITCHED WITH LIGHTS. SET OCCUPANCY SENSOR TO RUN 10 <br />MINUTES AFTER NO OCCUPANCY IS DETECTED. <br />RELAY FOR EXHAUST FAN. 120V EXHAUST FAN CIRCUIT SHALL BE ROUTED VIA RELAY THEN TO EXHAUST <br />® FAN. 277V LIGHTING CIRCUIT SWITCHED BY ROOM OCCUPANCY SENSOR SHALL CONTROL RELAY. <br />ETR EXISTING DEVICE OR FIXTURE TO REMAIN. RECONNECT AS INDICATED. <br />REP REPLACE EXISTING DEVICE. <br />NOTES: <br />1 • NEW LIGHTING FIXTURES SHALL BE SUPPLIED BY B.O.S., INSTALLED BY CONTRACTOR. <br />CONTACT IS LYN GREATREX OF E. SAM JONES CO., PHONE 1-888-851-1955, EMAIL Igreatrex@esamjones.com <br />2. INSTALL NEW LIGHTING CONTROLS, SEE LIGHTING CONTROL DIAGRAM. REROUTE EXISTING LIGHTING <br />CIRCUITS (INTERCEPT AND EXTEND) VIA LIGHTING CONTROL PANEL RELAYS AS NOTED. REMOVE ALL EXISTING <br />LIGHTING CONTROLS, TIMECLOCKS, CONTACTORS, ETC. <br />3. CONNECT BATTERY PACKS OF EMERGENCY LIGHTING FIXTURES (2X4, EXIT SIGNS AND UNIT EMERGENCY LIGHTING) <br />TO EMERGENCY LIGHTING CIRCUITS OR LIGHTING CIRCUIT AHEAD OF SWITCHING, RELAY OR CONTROLS. <br />/ V \\ // Y\\ <br />I/ I CONNECT BATTERY PACK OF <br />FLUORESCENT FIXTURES OR <br />NEW LIGHTING EMERGENCY UNIT EQUIP. TO THE LINE <br />CONTROL PANELS. SIDE OF THE LIGHTING CIRCUIT SERVING <br />NEMA 4X SEE LIGHTING REMOVE EXISTING B-29 AHEAD TIN COMPUTER,, LAD OF ANYSWITCHING, <br />9, 0„ CONTROL DIAGRAM. LIGHTING CONTACTORS OF CONTRO RESTROOMS. <br />A-3 A.F.F. AND TIMECLOCK NEMA 4X 9'-0" <br />A.F.F. <br />LIGHTING CONTROL DIGITAL AD <br />'C' 'B' 'A' JAN <br />A-3 SWITCH. MOUNT ADJACENT OF CONTROL B 1 O NG CO VIPLITE <br />B-12 B 12 TO BKBD. 48" AFF EF . . <br />B-29 B-29 - B-29 . . <br />m A-3 3-10 B-9 A-3 B-7 B-8 A-3 B-6 m <br />._ . STOCK / FIXTURES A L lo <br />. RECEIVING CHAIN HUNG <br />12'-0" AFF A-1 <br />_ B-29 AHEAD <br />B-29 B-29 B-29 OF CONTROL <br />B-9 B-10 B-9 B-8 B-7 B-8 B-7 B-6 <br />EF EF A-1 <br />B-29 AHEAD B-29 AHEAD R R. A-1 R <br />OF CONTROL OF CONTROL 1 <br />1H H H I <br />N <br />L i I I I m I I I� I 1 177 17 1®1 <br />B <br />12 <br />B-12 <br />v <br />m <br />�A-3� <br />-10 <br />B-9 <br />A-3 <br />B-7 <br />B-8 <br />A-3 <br />B-6 <br />B-5 <br />A-3 <br />B-5 <br />13-4 <br />A-1 <br />I B-4 <br />B-3 <br />I <br />I <br />I <br />A-1 <br />I <br />I <br />I <br />I B-1 <br />I B-2 <br />A-1 <br />I <br />Al <br />I <br />AI <br />I <br />I <br />III <br />IAl <br />I <br />Al <br />I <br />I. <br />AREA NOT WORK <br />in <br />I <br />OF BEALLS <br />OUTLET TENANT <br />O <br />O <br />O <br />A-1 <br />A-3 <br />B-9 <br />-10 <br />B-9 <br />B-8 <br />B-7 <br />B-8 <br />B-7 <br />B-6 <br />B-5 <br />B-6 <br />B-5 <br />B-4 <br />B-3 <br />I <br />B-4 <br />B-3 <br />B-2 <br />B-1 <br />B-2 <br />B-1 <br />I_] <br />in <br />— <br />A-3 <br />B-9 <br />B-10 <br />B-9 <br />B-8 <br />B-7 <br />B-8 <br />B-7 <br />B-6 <br />B-5 <br />B-6 <br />B-5 <br />B-4 <br />B-3 <br />B-4 <br />B-3 <br />B-2 <br />B-1 <br />I <br />B-2 <br />I <br />B-1 <br />IH <br />11--i <br />_H <br />111 <br />11 <br />1 <br />11 <br />H <br />11 <br />11 <br />1-1 <br />I <br />. <br />I <br />. <br />I <br />I <br />I <br />in <br />II <br />A-3 <br />-10 <br />I <br />B-9 <br />A-3 <br />I <br />B-7 <br />B-8 <br />A-3 <br />B-6 <br />B-5 <br />A-3 <br />B-5 <br />B-4 <br />A-1 <br />B-4 <br />B-3 <br />A-1 <br />B-1 <br />B-2 <br />A-1 <br />- <br />- <br />V <br />- <br />- <br />Ai <br />I <br />I <br />Al <br />I <br />1 <br />—1 <br />1 <br />1 <br />1 <br />1A <br />I <br />I <br />i <br />I <br />I <br />I <br />I <br />I i <br />- <br />[A <br />I <br />I <br />A] <br />in <br />i <br />B-9 <br />-10 <br />B-9 <br />B-8 <br />B-7 <br />B-8 <br />B-7 <br />B-6 <br />B-5 <br />B-6 <br />B-5 <br />B-4 <br />B-3 <br />B-4 <br />B-3 <br />B-2 <br />O <br />B-1 <br />B-2 <br />B-1 <br />A <br />3® <br />I <br />L <br />i <br />--i <br />in <br />O <br />S <br />LES <br />R <br />A <br />e <br />B-9 <br />-10 <br />B-9 <br />I B-8 <br />I B-7 <br />B-8 <br />B-7 <br />B-6 <br />B-5 <br />B-6 <br />I B-5 <br />B-4 <br />I <br />B-3 <br />B-4 <br />B-3 <br />B-2 <br />B-1 <br />B-2 <br />B-1 <br />I <br />L <br />A-3 <br />-10 <br />B-9 <br />I <br />A-3 <br />I B-7 <br />B-8 <br />A-3 <br />B-6 <br />I <br />B-5 <br />A-1 <br />B-5 <br />B-4 <br />A-1 <br />B-4 <br />I <br />B-3 <br />A-1 <br />B-1 <br />B-2 <br />A-1 <br />_ <br />. <br />H <br />H <br />I <br />IN <br />_ <br />I I <br />A] <br />in <br />LI <br />HTI <br />G <br />ON <br />ROL <br />DIG <br />TAL <br />S <br />ITC <br />. S <br />E F <br />ON <br />D <br />IC <br />J.B. <br />S F <br />R L <br />DDIISCIONWA <br />L. C <br />O <br />DIN <br />TE <br />C° <br />EL <br />VA <br />ION <br />AND <br />LIG <br />HTIN <br />G <br />LO <br />ATI <br />N AND <br />GONPIECI <br />ION <br />ROIJTE <br />IA NEW <br />7 <br />m <br />CONTROL <br />IAG <br />AM <br />LIG <br />TINGCONTROL <br />AN <br />L, CONTROLZO <br />E'B' <br />00 <br />.16— <br />J166— <br />J6— <br />J6— <br />J6— <br />J6.— <br />J6— <br />J6.— <br />J6— <br />—.16-7— <br />J6— <br />J6— <br />J6.— <br />J6.— <br />J6.— <br />B16 B- 16 A-1 B14 B14 A- B14 614 <br />B-3 <br />A-1 A-1 <br />� B- 14 B- 14 , <br />i _ r <br />A JUNCTION BOX FOR POWER TO BUILDING SIGNAGE. INSTALL <br />NEW CIRCUIT. CONTRACTOR SHALL CONNECT ALL WHIPS TO <br />B-28\ }� SIGNAGE DRIVERS / TRANSFORMERS. COORDINATE <br />v MOUNTING OF BOXES AND ROUTING OF WHIPS. <br />ROUTE CIRCUIT VIA THE NEW LIGHTING CONTROL PANEL, <br />CONTROL ZONE 'C'. <br />1 2 1 3 1 4 1 5 1 6 1 7 1 8 9 10 11 12 1 13 14 15 16 <br />LIGHTING PLAN N <br />1/8" = 1'-0" <br />17 18 <br />ME3 <br />CONSULTING ENGINEERS, LLC <br />5300 Paylor Lane <br />Sarasota, FL 34240 <br />Tel: 941-748-1319 Fax: 941-361-1221 <br />www.me3-engr.com sidney@me3-engr.com <br />Designed: BAK ME3 Job No: B17-1166 <br />Checked: BAK Date: 09/29/2017 <br />Drawn: BPZ C.O.A.27552 <br />Copyright 2017 ME3 All rights reserved <br />P <br />C <br />N <br />M <br />L <br />K <br />J <br />H <br />G <br />F <br />REV. I DESCRIPTION I DATE <br />BID & PERMIT SET E <br />09.29.17 <br />CURRENT ISSUE STATUS: <br />"To the best of the Architect's or <br />Engineer's knowledge, the plans <br />and specifications comply with the <br />applicable minimum building codes <br />and applicable fire safety standards <br />as determined by local authority in <br />accordance with Chapter 553 and <br />663 of Florida Statutes." <br />D <br />Bryan P. Zapf <br />Florida License # 46141 <br />WBRCIIIIIIIIIIIIIIINoI. <br />ARCHITECTS ENGINEERS <br />8130 Lakewood Main Street Phone: 941-556-0757 <br />Suite 210 Fax: 941-556-0759 <br />Lakewood Ranch, FL 34202 www.wbrcae.com <br />Finn Lic. # AA26001395 & 27389 Douglas WA"itney AIA <br />BEALLS OUTLET #542 <br />ZE P HYRH I LLS <br />PROJECT: 6030 Gall Blvd, Zephyrhills, FL 33542 B <br />LIGHTING PLAN <br />SHEET TITLE <br />WBRC CAD FILE <br />PROJECT No. 3542XX GRAPHIC SCALE: <br />ou ,� <br />SCALE: As Indicated L I A <br />PROJECT MANAGER: <br />SHEET No. <br />DRAWN BY: - E 1 02 <br />CHECKED BY: <br />19 20 <br />