Laserfiche WebLink
LOWER HANGER ATTACHMENTS <br />25044' ANGLES TRAPEZE HANGFRR <br />16 GA. x 1' WIDE STRAP OR ANGLE <br />STRAP HANGERS 3/8'0 ROD <br />HANGER <br />STRAPS <br />[>< MAX III X1 .11 <br />N SPACING <br />a <br />SIZE BOLT(S) FOR LOAD <br />1_6 <br />- #10 SM. SCREWS <br />LOAD RATED <br />FASTENERS <br />HANGER STRA7� <br />BAND OF SAME SIZE y <br />AS HANGER STRAP <br />TdHANGER RODS <br />OR STRAPS <br />BAND <br />5/8' DIA. MIN. <br />250440 ANGLES <br />ZWk1/4' ANGLES <br />SPAN 2 JOISTS <br />AVOID DISRUPTION <br />OF INSULATION <br />ROD <br />01 <br />PREFERRED --� <br />TRAP <br />ATTACHMENT <br />ANGLES 25c2'k1/4' �� NUT (TYP) <br />ALTERNATE LOCATIO <br />HANGERS FOR STACKED DUCTS <br />GENERAL NOTES: <br />REINFORCEMENT MAY BE USED FOR ATTACHMENT <br />IF IT QUALIFIES FOR BOTH DUTIES. <br />DO NOT EXCEED LOAD RATING FOR METHOD USED. <br />ING ENGINEERING ASSOCIATES, INC. REV. 01-11-16 MD-0512 <br />OAU CONDENSATE DRAIN PIPING 1 <br />CONDENSATE DRAIN CONNECTION <br />TO UNIT <br />PVC CLEANOUT <br />PLUG <br />SCHEDULE 40 PVC <br />TOTAL A <br />HEIGHT <br />MUST EQUAL OR <br />OF <br />TRAP <br />B <br />EXCEED TOTAL COIL <br />STATIC PRESS. (4' MIN) <br />REFER TO MECHANICAL <br />DRAWINGS. <br />DEEP SEAL TRAP <br />PROVIDE A SECONDARY <br />POSITIVE STATIC PRESSURE (BLOW-THRU) <br />DRAIN PAN (MINIMUM 3' <br />A= AT LEAST ONEW INCH PLUS CASING STATIC PRESSURE <br />DEEP AND 6' PAST UNIT IN <br />6= AT LEAST ONEW INCH <br />ALL DIRECTIONS. PAN SHALL <br />TOTAL HEIGHT OF TRAP-- A+B+(1b x PIPE DIA) <br />HAVE FLOAT SWITCH WIRED <br />TO SHUT DOWN UNIT IN <br />NEGATIVE STATIC PRESSURE (DRAW-THRU) <br />THE EVENT OF WATER IN <br />PAN. <br />A= ONE HALF (1/2) B <br />B= AT LEAST ONE (1) INCH PLUS CASING STATIC PRESSURE <br />TOTAL HEIGHT OF TRAP-- A+B+(1b x PIPE DIA) <br />CONSULTING ENGINEERING ASSOCIATES, INC. REV. 03-29-16 MD-0211 <br />REFRIGERANT PIPING PENETRATION THROUGH <br />EXTERIOR WALL <br />SEAL VOID AROUND PIPING WITH <br />3M FIRE SAFING OR FIRE PUTTY. <br />TOP FIRE SAFING/PUTTY WITH <br />SILICONE CAULK ON BOTH <br />INTERIOR AND EXTERIOR <br />SURFACES TO ENSURE A <br />WATER -TIGHT SEAL <br />REFRIGERANT PIPING SUCTION UNE <br />REFRIGERANT PIPING UQUID UNE <br />EXTERIOR WALL <br />SLEEVE ANCHOR, (2) 3/8'0 RODS. <br />PROVIDE SCHEDULE 40 STEEL <br />SLEEVE AS SMALL AS POSSIBLE <br />TO ACCOMMODATE PIPING. <br />SLEEVE FLUSH WITH INTERIOR <br />AND EXTERIOR OF WALL <br />REFRIGERANT PIPING SUCTION <br />LINE COPPER PIPE WITH <br />ARMAFLEX INSULATION. SIZE PER <br />MANUFACTURERS <br />SPECIFICATIONS. PAINT ALL <br />EXPOSED INSULATION WITH TWO <br />COATS OF WHITE ARMAFLEX <br />PAINT. <br />REFRIGERANT PIPING LIQUID <br />LINE BARE COPPER PIPE <br />SIZE PER MANUFACTURERS <br />SPECIFICATIONS. <br />CONSULTING ENGINEERING ASSOCIATES, INC. REV: 01-14-16 MD-0825 <br />REPLACEMENT EVAPORATOR COILS <br />MARK --- AHU-1 AHU-2 <br />COOLING <br />TOTAL CAPACITY <br />BTUH <br />191,500 <br />165,300 <br />SENSIBLE CAPACITY <br />BTUH <br />153,900 <br />129 500 <br />TOTAL AIR FLOW <br />CFM <br />7150 <br />6000 <br />OUTSIDE AIR FLOW <br />CFM <br />1200 <br />1520 <br />EXTERNAL STATIC PRESSURE <br />IN WG <br />1.5 <br />1.5 <br />ENT. AIR TEMP DB WB <br />DEG F DEG F <br />74.5 62.5 <br />74.3 62.4 <br />LVG. AIR TEMP DB WB <br />DEG F DEG F <br />54.8 53.3 <br />54.6 52.9 <br />COOLING COIL MIN MAX <br />ROWS FINS PER INCH <br />6 10 <br />6 10 <br />COOLING COIL MAX FACE VEL. <br />FPM <br />424 <br />501 <br />COOLING COIL MAX PRESS. DROP <br />IN WG <br />0.63 <br />0.86 <br />REFRIGERANT TYPE <br />- <br />R-410a <br />R-410a <br />SUCTION TEMP <br />DEG F <br />48.5 <br />45.5 <br />NOTES: <br />1. PROVIDE STAINLESS STEEL COIL CASINGS AND COIL SUPPORTS. <br />100% OAU SUPPORT - FLOOR MOUNTED <br />OUTSIDE a PROVIDE DUCT MOUNTED <br />DUCT F <br />AIR SMOKE DETECTOR AS <br />. <br />PROVIDE 4' FLEXIBLE <br />CONNECTOR AT <br />SUPPLY AND OUTSIDE <br />AIR DUCT <br />CONNECTIONS. <br />FILTER SECTION <br />SUPPLY <br />DUCT <br />PAN TO EXTEND A <br />MINIMUM OF 6' PAST <br />UNIT IN ALL DIRECTIONS. <br />3' DEEP SECONDARY <br />DRAIN PAN <br />PROVIDE FIVE SIDED, EXTERNALLY INSULATED PLENUM BOX ON SICE OF OAU <br />FOR OUTSIDE AIR DUCT CONNECTION. BOX TO BE A MINIMUM OF 6' AFF. <br />SIZE BOX PER UNIT DIMENSIONS AND RETURN DUCT/OUTSIDE AIR DUCT SIZE <br />REQUIREMENTS. <br />CONSULTING ENGINEERING ASSOCIAT <br />TYPICAL BRANCH DUCTS <br />3 <br />09 <br />LL <br />Q <br />OPPOSED BLADE <br />DAMPER <br />CONSULTING ENGINEERING <br />REQUIRED. <br />DUCT CONNECTIONS <br />TO BE A MINIMUM OF <br />TWO FAN DIAMETERS <br />IN DISTANCE FROM <br />TOP OF UNIT. <br />FAN SECTION. ENSURE <br />FAN IS ROTATED AS <br />REQUIRED FOR DUCT <br />CONNECTION. <br />COIL SECTION <br />- CONTRACTOR TO <br />CONSTRUCT GALVANIZED <br />STEEL FRAME UNDER <br />UNIT FOR SUPPORT. USE <br />SIMPLE' FRAMING <br />PROCEDURES. SIZE <br />APPROPRIATELY FOR UNIT <br />WEIGHT. <br />CONDENSATE <br />PIPING, REFER <br />TO AHU <br />�- CONDENSATE <br />DRAIN PIPING <br />DETAIL <br />- FLOAT SWITCH <br />- 1' THICK NEOPRENE PAD <br />REV:08-08-16 MD-0443 <br />OPPOSED BLADE <br />DAMPER <br />- PROVIDE 2' <br />STAND-OFF FOR <br />INSULATED DUCTS <br />INC. REV.10-27-16 1 MD-0504B <br />EXISTING AIR HANDLER UNIT DATA <br />MARK <br />AHU-1 <br />AHU-2 <br />TOTAL AIR FLOW <br />CFM <br />7150 <br />6000 <br />OUTSIDE AIR FLOW <br />CFM <br />1200 <br />1520 <br />STATIC PRESSURE <br />EXT. TOT. <br />1.5 2.73 <br />1.5 2.01 <br />MOTOR <br />HP BHP <br />10 7.9 <br />7.5 5.11 <br />FAN TYPE <br />MIN. DIA. <br />AF 15 <br />AF 15 <br />FAN RPM <br />MAX. <br />2331 <br />2016 <br />FAN OUTLET <br />VEL. MAX <br />3505 <br />3039 <br />ELECTRICAL <br />V PH HZ <br />208 3 <br />208 3 <br />TOTAL CAPACITY <br />BTUH <br />185600 <br />162900 <br />SENS. CAPACITY <br />BTUH <br />154000 <br />130900 <br />COIL ENT. AIR TEMP. DB WB <br />74.5 62.5 <br />74.3 62.4 <br />COIL LVG. AIR TEMP. DB WB <br />54.8 53.5 <br />55 53.3 <br />COIL <br />ROWS FINS <br />8 '9 <br />5 '8 <br />COIL FACE VELOCITY <br />MAX <br />500 <br />450 <br />SATURATED SUCTION TEMP <br />42 <br />42.5 <br />AIR PRESS. DROP <br />MAX. <br />0.99 <br />0.32 <br />EXTERNAL FACE & BYPASS <br />----- <br />N/A <br />N/A <br />FILTER TYPE <br />----- <br />2" <br />2" <br />EFFICIENCY ASHRAE 52-89 <br />----- <br />30% <br />30% <br />MEDIAN P.D. <br />EACH <br />0.61 <br />0.63 <br />MANUFACTURER <br />----- <br />YORK <br />YORK <br />MODEL NO. <br />----- <br />AP-150 <br />AP-150 <br />UNIT WEIGHT <br />LBS. <br />2197 <br />2277 <br />NOTES <br />ALL <br />ALL <br />NOTES: <br />1. THIS SCHEDULE HAS BEEN REPRODUCED FROM EXISTING RECORD DOCUMENTS BY CONSULTING <br />ENGINEERING ASSOCIATES, INC. ISSUED OCTOBER 3, 2002, FOR REFERENCE ONLY. <br />DIRECT EXPANSION AIR COOLED CONDENSING UNIT SCHEDULE <br />MARK <br />--- <br />CU-1 A <br />CU-1 B <br />CU-2A <br />CU-2B <br />CAPACITY <br />BTUH <br />90,600 <br />90 600 <br />85,400 <br />85,400 <br />AMBIENT TEMP. <br />DEG F <br />95 <br />95 <br />95 <br />95 <br />SUCTION TEMP. <br />DEG F <br />48.5 <br />48.5 <br />45.5 <br />45.5 <br />WEIGHT <br />LBS <br />390 <br />390 <br />390 <br />390 <br />REFRIGERANT TYPE <br />--- <br />R-410A <br />R-410A <br />R-410A <br />R-41OA <br />NO. OF CIRCUITS <br />--- <br />1 <br />1 <br />1 <br />1 <br />UNLOADING <br />STEP MIN <br />100-0 <br />100-0 <br />100-0 <br />100-0 <br />COMPRESSOR <br />NO <br />1 <br />1 <br />1 <br />1 <br />COMPRESSOR RLA EACH <br />AMPS <br />25 <br />25 <br />25 <br />25 <br />COMPRESSOR (LRA EACH <br />AMPS <br />164 <br />164 <br />164 <br />164 <br />CONDENSER FAN <br />NO. HP <br />2 TO.33 <br />2 0.33 <br />2 0.33 <br />2 0.33 <br />CONDENSER FAN FLA EACH <br />AMPS <br />2.1 <br />2.1 <br />2.1 <br />2.1 <br />EER <br />--- <br />12.4 <br />12.4 <br />12.4 <br />12.4 <br />TOTAL UNIT MCA <br />AMPS <br />35.5 <br />35.5 <br />35.5 <br />35.5 <br />TOTAL UNIT MOCP <br />AMPS <br />45 <br />45 <br />45 <br />45 <br />ELECTRICAL <br />V PH HZ <br />208 3 60 <br />208 3 60 <br />208 3 60 <br />208 3 60 <br />MANUFACTURER <br />--- <br />JCI <br />JCI <br />JCI <br />JCI <br />MODEL <br />--- <br />J07YCCOOA2AA65 <br />J07YCCOOA2AAB5 <br />J07YCCOOA2AAB5 <br />J07YCCOOA2AAB5 <br />NOTES <br />1 12345 <br />2345 <br />1 12345 <br />1 2345 <br />NOTES: <br />1. PROVIDE RAWALL DEVICE FACTORY INSTALLED <br />2. PROVIDE ONE INCH THICK NEOPRENE PAD(S) BETWEEN CONDENSING UNIT AND CONCRETE PAD. <br />3. DISCONNECT PROVIDED BY DIVISION 26. <br />4. SECURE CONDENSING UNIT TO CONCRETE PAD USING 1" WIDE, 10 GAGE SHEET METAL <br />STRAPS NEATLY SECURED TO THE UNIT AND BASE SUPPORT USING 1" STAINLESS STEEL SCREWS. <br />COORDINATE LOCATIONS OF SCREWS WITH STRUCTURAL COMPONENTS OF THE UNIT. <br />DO NOT BLOCK SERVICE ACCESS. <br />5. MANUFACTURER SHALL SIZE REFRIGERANT PIPING AND PROVIDE ALL REFRIGERANT SPECIALTIES. <br />CONDENSING UNIT ON GRADE <br />PROVIDE CONDENSER <br />FAN GUARD <br />ALL SCREWS SHALL <br />BE J14 GASKETED <br />WASHER SCREWS, <br />STAINLESS STEEL <br />CONSULTING ENGI <br />CONDENSING UNIT <br />PROVIDE <br />CONDENSER <br />COIL GUARDS <br />PROVIDE <br />CONTINUOUS 22 <br />GAUGE STAINLESS <br />STEEL STRAPS <br />(THREE PER SIDE) <br />1' THICK NEOPRENE PAD(S) <br />EXISTING CONCRETE PAD TO <br />EXTEND A MINIMUM OF 6' <br />AROUND ALL SIDES OF UNIT. <br />INC. REV: 07-25-16 MD-0444 <br />VOLUME DAMPERS FOR DUCTWORK 6 <br />J <br />' ' <br />� <br />I�jl <br />ill■ <br />-. <br />L <br />FIG. C <br />ROUND DAMPER <br />o <br />o <br />DUCT <br />FIG D <br />ELEVATION <br />TWO BLADE ARRANGEMENT <br />30 QUADRANT DUCT <br />BEARING OPTION <br />1/2' QUADRANT DUCT <br />30 PIN <br />FOR SINGLE <br />1/2' ROD -PIN <br />BLADE DAMPERS <br />mi <br />22 GA. BLADE <br />16 GA. BLADE <br />10 CLEARANCE ALL <br />AROUND <br />1)W CLEARANCE ALL <br />C+FNFRgI NnTF• <br />AROUND <br />UP TO 18 <br />-- - - -• <br />OVER 4' HIGH USE <br />19' TO 48' <br />FIG. <br />MULTIPLE BLADES <br />FIG. B <br />STIFFEN AS <br />orniuDan <br />0 0 6 6 <br />OUTSIDE INSIDE <br />END BEARING END BEARING <br />FIG. A OR REQUIRED ON 2' Wra <br />SIDE ELEVATION CLASS DUCT. OPTIONAL <br />ON OTHERS. <br />CONSULTING ENGINEERING ASSOCIATES, INC. I REV: 01-11-16 MD-0508 <br />EXISTING DEHUMIDIFICATION UNIT SCHEDULE <br />MARK <br />- <br />OA-1 <br />COOLING CAPACITY <br />MBH <br />257565 <br />SENSIBLE CAPACITY <br />MBH <br />117846 <br />ENTERING AIR TEMP. <br />'FDB °FWB <br />91 79 <br />LEAVING AIR TEMP / COIL/ UNIT <br />-FDB 'FWB <br />52 51.5 72 61.8 <br />LEAVING AIR DEWPOINT, MAXIMUM <br />-F <br />50.8 <br />AIRFLOW <br />CFM <br />2720 <br />EXT./TOT. STATIC PRESSURE <br />IN. WTR. <br />.75 1.75 <br />EVAPORATOR FAN <br />HP BHP <br />3 <br />EVAPORATOR FAN <br />RPM <br />1750 <br />DEHUMIDIFICATION COIL <br />ROWS MIN. <br />6 <br />MIN. SATURATED SUCTION TEMP <br />'F FULL LOAD <br />47.3 <br />ELECTRIC HEAT <br />KW TYPE <br />25 SCR CONTROL <br />FILTER TYPE EFF <br />- % <br />30 <br />NUMBER OF COMPRESSORS MIN. <br />- <br />1 <br />ELECTRICAL <br />V PH Hz <br />208 3 60 <br />COMPRESSOR <br />FLA <br />37.4,37.4 <br />EVAPORATOR FAN <br />FLA <br />7 <br />MINIMUM CIRCUIT AMPS <br />- <br />95 <br />REC. FUSE SIZE <br />- <br />110 <br />UNIT EER <br />MIN. <br />12 <br />WEIGHT <br />LBS <br />1700 <br />MANUFACTURER <br />- <br />DESERT AIRE <br />MODEL <br />- <br />Total Aire 20 <br />REMOTE CONDENSER <br />THR <br />316805 <br />NUMBER OF FANS <br />- <br />2 <br />MINIMUM CIRCUIT AMPS <br />- <br />14 <br />REC. FUSE SIZE <br />- <br />20 <br />MANUFACTURER <br />- <br />DESERT AIRE <br />MODEL <br />- <br />ROC 0021 <br />NOTES: <br />ALL <br />NOTES: <br />1. THIS SCHEDULE HAS BEEN REPRODUCED FROM EXISTING RECORD DOCUMENTS BY CONSULTING <br />ENGINEERING ASSOCIATES, INC. ISSUED OCTOBER 3, 2002, FOR REFERENCE ONLY. <br />DIRECT EXPANSION OUTSIDE <br />AIR UNIT REMOTE CONDENSER SCHEDULE <br />MARK <br />--- <br />OACU-1 <br />CAPACITY <br />BTUH <br />262,500 <br />AMBIENT TEMP. <br />DEG F <br />95 <br />WEIGHT <br />LBS <br />369 <br />REFRIGERANT TYPE <br />--- <br />R-410A <br />NO. OF CIRCUITS <br />--- <br />1 <br />CONDENSER FAN <br />NO. <br />2 <br />CONDENSER FAN FLA EACH <br />AMPS <br />3.3 <br />TOTAL UNIT MCA <br />AMPS <br />9 <br />TOTAL UNIT MOCP <br />AMPS <br />12 <br />ELECTRICAL <br />V PH HZ <br />230 3 60 <br />MANUFACTURER <br />--- <br />DESERT AIRE <br />MODEL <br />--- <br />RC5SO67 <br />NOTES <br />--- <br />ALL <br />NOTES: <br />1. REFRIGERANT LINES TO BE SIZED PER MANUFACTURER'S SPECIFICATIONS. <br />2. PROVIDE ONE INCH THICK NEOPRENE PAD(S) BETWEEN CONDENSER AND <br />CONCRETE PAD. <br />3. SECURE CONDENSER TO CONCRETE PAD USING 1" WIDE, 10 GAGE SHEET <br />METAL STRAPS NEATLY SECURED TO THE UNIT AND BASE SUPPORT USING <br />1" STAINLESS STEEL SCREWS. COORDINATE LOCATIONS OF SCREWS WITH <br />STRUCTURAL COMPONENTS OF THE UNIT. DO NOT BLOCK SERVICE <br />ACCESS. <br />4. DISCONNECT PROVIDED BY DIVISION 26. <br />FPIPE HANGERS 11 <br />ALL THREADED HANGER ROD <br />LOCKING NUT <br />HEAVY DUTY CLEVIS HANGER <br />INSULATION WITH---,, <br />VAPOR BARRIER <br />PIPING �� <br />18 GA GALVID STEEL <br />SADDLE 3 TIMES <br />PIPE DIAMETER OR <br />9' MIN. LENGTH. <br />ALL THREADED HANGER ROD <br />LOCKING NUT <br />SUPPORT NUT <br />HEAVY DUTY CLEVIS HANGER <br />INSULATION WITH <br />VAPOR BARRIER <br />PIPING <br />18 GA. GALVID STEEL <br />SADDLE 3 TIMES <br />PIPE DIAMETER OR <br />9' MIN. LENGTH. <br />CONSULTING ENGINEERING ASSOCIATES, INC. REV: 01-14-16 <br />rRECTANGLAR DUCT HANGERS MINIMUM SIZES <br />MAXIMUM <br />PAIR AT <br />PAIR AT <br />PAIR AT <br />PAIR AT <br />HALF OF <br />10 FT. SPACING <br />8 FT. SPACING <br />5 FT. SPACING <br />4 FT. SPACING <br />DUCT <br />PERIMETER <br />STRAP <br />ROD <br />STRAP <br />ROD <br />STRAP <br />ROD <br />STRAP <br />ROD <br />P <br />2 <br />1' x 22 GA. <br />1/4' <br />1' x 22 GA <br />1/4' <br />1' x 22 GA <br />1/4' <br />1' x 22 GA. <br />1/4' <br />P <br />2 = 96' <br />1' x 18 GA. <br />3/8' <br />1' x 20 GA <br />1/4' <br />1' x 22 GA. <br />1/4' <br />1' x 22 GA. <br />1/4' <br />P <br />2 = 120' <br />1' x 16 GA. <br />30 <br />1' x 18 GA. <br />3/8' <br />1' x 22 GA. <br />1/4' <br />1' x 22 GA. <br />1/4' <br />P <br />2 = 168' <br />1B' x 16 GA <br />1/2' <br />1' x 16 GA. <br />3/8' <br />1' x 18 GA. <br />3/8' <br />1' x 18 GA. <br />3/8' <br />P <br />= 192' <br />2 <br />1/2' <br />15' x 16 GA. <br />1/2' <br />1' x 16 GA. <br />30 <br />1' x 16 GA. <br />3/8' <br />P = 193, UP <br />2 <br />SPECIAL ANALYSIS REQUIRED <br />WHEN STRAPS ARE LAP JOINED <br />SINGLE HANGER <br />USE THESE MINIMUM FASTENERS. <br />MAXIMUM ALLOW. LOAD <br />V x 18, 20,22 GA. - TWO #10 <br />1' x 22 GA. - 260 LBS. 1/4 DIA. 270 LBS. <br />?x 16 GA. - TWO 1/4' DIA <br />T x 20 GA. - 320 LBS. 3/8 DIA 680 LBS. <br />1.7 x 16 GA - TWO 3/8' DIA <br />1' x 18 GA - 420 LBS. 1/2 DIA. 1250 LBS. <br />PLACE FASTENERS IN SERIES, <br />1' x 16 GA. - 700 LBS. 5/8 DIA 2000 LBS. <br />NOT SIDE BY SIDE <br />1.5' x 16 GA - 1100 LBS. 3/4 DIA. 3000 LBS. <br />NOTES: <br />1. DIMENSIONS OTHER THAN GAGE ARE IN INCHES. <br />2 TABLES ALLOW FOR DUCT WEIGHT, OS LB/SF INSULATION WEIGHT & NORMAL REINFORCEMENT AND <br />TRAPEZE WEIGHT, BUT NO EXTERNAL LOADSI <br />3. CONSULT AISI LIGHT GAGE STEEL DESIGN MANUAL AND AISC STEEL CONSTRUCTION MANUAL FOR CRITERIA <br />FOR DESIGN OF OTHER HANGERS. <br />4. STRAPS ARE GALVANIZED STEEL; OTHER MATERIALS ARE UNCOATED STEEL <br />5. ALLOWABLE LOADS LISTED ASSUME THAT DUCTS ARE 16 GA. MAXIMUM. <br />CONSULTING ENGINEERING ASSOCIATES, INC. REV: 01-11-16 MD-0511 <br />DIRECT EXPANSION 100% OUTSIDE AIR UNIT SCHEDULE <br />MARK --- OAU-1 <br />COOLING <br />TOTAL CAPACITY <br />BTUH <br />212,960 <br />SENSIBLE CAPACITY <br />BTUH <br />101,532 <br />TOTAL AIR FLOW <br />CFM <br />2720 <br />EXTERNAL STATIC PRESSURE <br />IN WG <br />0.8 <br />EVAP COIL ENT. AIR TEMP. DB WB <br />DEG F DEG F <br />91.0 79.0 <br />EVAP COIL LVG. AIR TEMP. DB WB <br />DEG F DEG F <br />56.9 56.9 <br />REHEAT COIL LVG. AIR TEMP. DB RH <br />DEG F RH <br />72460 <br />DEHUMIDIFICATION COIL MIN MAX <br />ROWS FINS PER INCH <br />6 12 <br />DEHUMIDIFICATION COIL MAX FACE VEL. <br />FPM <br />400 <br />DEHUMIDIFICATION COIL MAX PRESS. DROP <br />IIN WG <br />1 0.3 <br />HEATING <br />LOCATION <br />--- <br />IN UNIT <br />TOTAL CAPACITY <br />KW STEPS <br />I 25 SCR <br />UNIT <br />DRIVE <br />--- <br />Belt <br />FAN TYPE <br />--- <br />FC <br />FAN MOTOR <br />HP <br />2.0 <br />REFRIGERANT TYPE <br />--- <br />R-410A <br />COMPRESSOR <br />NO./HP <br />2 7.5 <br />COMPRESSOR (RLA EACH <br />AMPS <br />29.5 <br />EVAPORATOR FAN <br />N0. HP <br />2.0 <br />MRE PER AHRI 920 <br />--- <br />7.9 <br />TOTAL UNIT MCA <br />AMPS <br />96 <br />TOTAL UNIT MOCP <br />AMPS <br />100 <br />ELECTRICAL <br />V PH HZ <br />230 3 60 <br />FILTER <br />MERV <br />8 <br />WEIGHT <br />LBS <br />1444 <br />MANUFACTURER <br />--- <br />DESERT AIRE <br />MODEL <br />--- <br />QV15 <br />NOTES <br />--- <br />ALL <br />NOTES: <br />1. UNIT PERFORMANCE TO MEET MINIMUM LEAVING AIR TEMPERATURE AND DEWPOINT VALUES. <br />2. PROVIDE MINIMUM 6 ROW DEHUMIDIFICATION COIL - NO EXCEPTIONS. <br />3. PROVIDE VARIABLE HOT GAS REHEAT CONTROL TO MAINTAIN DESIRED AIR TEMPERATURE <br />WITHIN PLUS OR MINUS 2 DEG F UNDER ALL AMBIENT CONDITIONS. <br />4. PROVIDE HOT GAS BYPASS. <br />5. PROVIDE FULL COOLING PERFORMANCE OPTION (REFRIGERANT REHEAT OFF). <br />6. PROVIDE SLOPED IAQ STAINLESS STEEL DRAIN PAN. <br />7. PROVIDE DOUBLE WALL CONSTRUCTION - NO EXECPTIONS. <br />8. PROVIDE STAINLESS STEEL CABINET HARDWARE - ZINC PLATED NOT ACCEPTABLE. <br />9. ALL STARTERS/CONTROLS TO BE FACTORY INSTALLED. <br />10. PROVIDE SINGLE POINT POWER CONNECTION. <br />11. PROVIDE CONTACT CLOSURE SIGNAL FOR MOTORIZED OCCUPANCY DAMPERS IN FIELD <br />PROVIDED DUCTWORK. <br />12. UNIT TO BE ETL LISTED AND LABELED AND FULLY FACTORY RUN TESTED. <br />13. DISCONNECT FURNISHED AND INSTALLED BY DIVISION 26. <br />PERFORMANCE STANDARD: <br />THIS IS A 100% DEDICATED OUTDOOR AIR SYSTEM (DOAS); PERFORMANCE IS OF THE UTMOST <br />IMPORTANCE TO THE QUALITY OF THE INDOOR AIR ENVIRONMENT. THIS UNIT IS SPECIFIED TO <br />PRODUCE A LEAVING AIR TEMPERATURE, AND RESULTING RELATIVE HUMIDITY, TO WITHIN PLUS <br />OR MINUS 2.0 DEGREES FAHRENHEIT OF SET -POINT. THERE WILL BE NO EXCEPTIONS. <br />DESERT AIRE AND DECTRON ARE ACCEPTABLE MANUFACTURERS OF THIS PRODUCT. ALL <br />MANUFACTURER'S, INCLUDING THE TWO LISTED MANUFACTURERS, WISHING TO BID THEIR <br />PRODUCT MUST CERTIFY IN WRITING VIA U.S. MAIL TO THE ENGINEER 10 DAYS PRIOR TO BID <br />DATE (AND AGAIN INCLUDED IN THE SUBMITTAL DOCUMENTS) THAT THE EQUIPMENT PROVIDED <br />WILL MEET THE LEAVING AIR TEMPERATURE REQUIREMENTS OF PLUS OR MINUS 2.0 DEGREES <br />FAHRENHEIT IN ALL OPERATIONAL CONDITIONS. THE LETTER OF CERTIFICATION MUST BE SIGNED <br />BY ONE OF THE MANUFACTURERS CORPORATE OFFICERS IN THE FORM OF A LETTER TO THE <br />ENGINEER OF RECORD. THE CERTIFICATION LETTER MUST CONFIRM THAT THE SUBMITTED <br />EQUIPMENT WILL OPERATE THE COMPRESSORS AT AN ENTERING AIR TEMPERATURE TO A <br />MINIMUM OF THE SPECIFIED EQUIPMENTS DESIGNED LEAVING AIR DEW -POINT, NO <br />EXCEPTIONS, AND THAT THE UNIT WILL MEET THE LEAVING AIR TEMPERATURE REQUIREMENTS <br />OF PLUS OR MINUS 2.0 DEGREES FAHRENHEIT IN ALL OPERATIONAL CONDITIONS, NO <br />EXCEPTIONS. FURTHERMORE, AT NO ADDITIONAL COST TO THE OWNER, THE MANUFACTURER <br />MUST PROVIDE SUPCO LTH DATA LOGGERS, ACCURATE TO 1.0 DEGREE FAHRENHEIT, MOUNTED <br />IN THE DISCHARGE AIR AND ENTERING AIR DUCTS, TO TEST THE UNIT FOR LEAVING AIR <br />TEMPERATURE AND HUMIDITY COMPLIANCE UNDER THE TESTED ENTERING AIR <br />TEMPERATURE. DATA SHALL BE LOGGED EVERY THREE MINUTES, RECORDED IN AN EXCEL <br />SPREADSHEET FORMAT WITH CORRESPONDING CHARTS DOCUMENTING THE UNITS <br />PERFORMANCE, PROVIDED MONTHLY TO THE ENGINEER. DATA SHALL BE CERTIFIED BY THE <br />MANUFACTURER. TESTING SHALL COMMENCE AT TIME OF BUILDING TURNOVER TO THE OWNER <br />AND CONTINUE FOR A PERIOD OF 3 MONTHS. FAILURE TO COMPLY WITH THE SPECIFIED <br />TEMPERATURE AND HUMIDITY CONTROL REQUIREMENTS WILL REQUIRE REMOVAL OF THE <br />SUBSTANDARD EQUIPMENT AND REPLACEMENT WITH EQUIPMENT COMPLYING WITH THE PROJECT <br />REQUIREMENTS AT NO ADDITIONAL COST TO THE OWNER. ALL ADDITIONAL TIME REQUIRED IN <br />RETESTING, MEETING ATTENDANCE BY THE ENGINEER, AND DATA REVIEW SHALL BE PAID FOR <br />BY THE MANUFACTURER OF THE SUBSTANDARD EQUIPMENT. <br />CONSULTING <br />ENGINEERING <br />ASSOCIATES <br />SEAL <br />8365 GUNN HIGHWAY <br />TAMPA, FL 33626 <br />(81W) 448-0225 <br />FAX (813) 448-0226 <br />EB - 0003962 <br />Mechanical Plumbing <br />Fire Protection <br />BIDDING DOCUMENTS <br />SIGNATURE DATE <br />JOHN W. WELLS, III, PE <br />PE 0049347 <br />zN <br />O� <br />LO <br />p <br />M <br />�a <br />u� <br />wo <br />U. <br />J <br />OCo <br />� J <br />J = ~ <br />2W W <br />�- N W <br />aW U <br />W � J <br />N <br />Lim W <br />0 <br />..moo �U <br />WLU <br />mr <br />�� �a <br />REVISIONS <br />delta date revision <br />SHEET TITLE <br />HVAC <br />DETAILS AND <br />SCHEDULES <br />SHEET NO.: <br />M- <br />TMH/ JWW <br />02/12/19 <br />18010 <br />501 <br />