My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6512 Gall Blvd (8)
Zephyrhills
>
Building Department
>
Building Plans
>
6512 Gall Blvd (8)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:26:41 AM
Creation date
2/25/2025 4:13:38 PM
Metadata
Fields
Template:
Building Plans
Street #
6512
Location
Gall Blvd
Contractor
Dystra Construction
Building Plans - Permit #
21700
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PROVIDE SHEETMETAL SADDLE <br />AND HANGERS TO PREVENT <br />SAGGING. PLENUM -RATED RUBBER/ <br />PLASTIC SUPPORT BANDS SHALL <br />BE ACCEPTABLE. <br />ROUND METAL DUCT OR <br />FLEX DUCT (INSULATED) <br />FOR FLEX DUCT SECURE SA AND RA, TOP <br />AND BOTTOM WITH BAND ON INSIDE LINER <br />AND WITH BAND ON OUTSIDE OF INSULATION <br />F-0" MAX FLEX PLENUM RATED BANDS OR <br />DUCT LENGTH SCREW CLAMPS-TYP <br />TURNING VANES <br />INSULATION <br />DUCT COLLAR <br />1 TYPICAL DIFFUSER <br />W. �— CEILING <br />DIFFUSER CONNECTION DETAIL SCALE 1 <br />- LOW CLEARANCE N.T.S. <br />PROVIDE SHEET METAL SADDLE AND HANGERS TO <br />PREVENT SAGGING. PLENUM -RATED RUBBER/ PLASTIC <br />SUPPORT BANDS OR THERMAFLEX FLEXFLOW ELBOW <br />5'-0" MAX FLEX DUCT LENGTH SUPPORT SHALL BE ACCEPTABLE. <br />FOR FLEX DUCT SECURE SA AND RA, <br />TOP AND BOTTOM WITH BAND ON INSIDE <br />FD LINER AND WITH BAND ON OUTSIDE OF <br />INSULATION <br />ROUND METAL DUCT R=D <br />TYPICAL DIFFUSER <br />PLENUM RATED BAND OR <br />SCREW CLAMPS TYPICAL 6' —_ j CEILING <br />DIFFUSER CONNECTION DETAIL SCALE 2 <br />- TYPICAL CLEARANCE N.T.S. <br />1/4W 4" MINIMUM <br />SUPPLY DUCT <br />450 CLINCH COLLAR WITH <br />MANUAL DAMPER, LOCKING <br />SUPPLY DUCT <br />U <br />ROUND BRANCH DUCT <br />HAND QUADRANT, AND 2" <br />OJ <br />p <br />BRANCH DUCTWORK <br />STAND-OFF BRACKET <br />ROUND BRANCH DUCT <br />Q <br />j <br />z <br />/ <br />Q Q <br />O <br />O <br />( <br />o <br />RECTANGULAR OR <br />, <br />,) <br />SQUARE BRANCH DUCT <br />�5a <br />DUCTWORK TRANSITION <br />MANUAL DAMPER WITH <br />MANUAL DAMPER WITH <br />(300 DUCT SLOPE) <br />LOCKING QUADRANT WITH <br />SUPPLY DUCT <br />LOCKING QUADRANT <br />p <br />2" STAND OFF BRACKET <br />WITH 2" STAND OFF <br />zQ <br />f <br />BRACKET (NO SCOOPS) <br />Q <br />w <br />I <br />RECTANGULAR TO ROUND <br />ROUND TO ROUND <br />RECTANGULAR/SQUARE TO <br />RECTANGULAR/SQUARE TO <br />CONNECTION (PLAN VIEW) <br />CONNECTION <br />RECTANGULAR/SQUARE CONNECTION <br />ROUND CONNECTION <br />PER ROD <br />INSULATION (VAPOR BARRIER TYPE IS <br />REQUIRED FOR LOW TEMPERATURE PIPE) <br />INSULATION (VAPOR BARRIER TYPE IS <br />REQUIRED FOR LOW TEMPERATURE PIPE) <br />INSULATION SHIELD AT HANGER <br />ADJUSTABLE CLEVIS HANGER <br />TYPE 1 IN SPECIFICATIONS <br />ROD <br />INSULATION <br />WELD <br />SADDLE <br />ADJUSTABLE ROLLER HANGER <br />TYPE 44 IN SPECIFICATIONS <br />FIELD WRAPPER 18.00" NIGH <br />54, <br />(SEE HOOD OPTIONS TABLE) <br />EXHAUST RISER <br />SUPPLY RISER WITH <br />VOLUME DAMPER <br />23.5% OPEN STAINLESS <br />yq STEEL PERFORATED PANEL <br />20" CAPTRATE SOLO <br />FILTER WITH HOOK <br />24" -� <br />3" INTERNAL STANDOFF <br />24' NOM. <br />18" <br />MINIMUM 10' <br />48.0" MAX <br />GREASE DRAIN <br />WITH REMOVABLE CUP <br />BACKSPLASH 80, <br />H GH <br />X 88.00" LONG <br />80" <br />80. <br />q• <br />FRYER <br />36.0" <br />2�• <br />GAS CHASE CUTOUT <br />1/2" <br />(FOR GAS AND POWER LINES) <br />21" <br />LEFT AND RIGHT VERTICAL END PANELS <br />27• <br />WITH ADJUSTABLE LEGS <br />EQUIPMENT ELEVATIONS <br />SCALE <br />- KITCHEN HOOD & EXHAUST <br />N.T.S. <br />BRANCH DUCT CONNECTION DETAIL I <br />SCALE 4 <br />N.T.S. <br />1/2" DIA. HANGER RODS WITH 36" <br />MAX. SPACING ON EACH CHANNEL <br />PROVIDE INSULATION SHIELD <br />AND INSERT FOR ALL PIPING <br />BAND <br />1 5/8" 12 GAUGE CHANNEL <br />OR 2"x2"x1/4" ANGLE <br />MAXIMUM PIPE/TUBING SUPPORT SPACING (FT) <br />NOM. SIZE <br />THRU 3/4" <br />1 <br />1-1/4 <br />1-1/2 <br />2 <br />2-1/2 <br />3 <br />4 <br />1 5 <br />1 6 <br />8 <br />10 <br />PIPE <br />7(FT) <br />7 <br />7 <br />9 <br />10 <br />11 <br />12 <br />14 <br />16 <br />17 <br />19 <br />22 <br />TUBING <br />5 (FT) <br />6 <br />7 <br />8 <br />8 <br />9 <br />10 <br />12 <br />13 <br />14 <br />16 <br />- <br />(SIDE VIEW) TRAPEZE HANGER FOR <br />UP TO 1000 LB. UNIFORM LOAD <br />PIPE HANGERS DETAIL I <br />SCALE 5 <br />N.T.S. <br />NOTES: <br />1. <br />ALL THERMOSTATS SHALL BE INSTALLED AT 42" AFF <br />STRUCTURAL. DECK <br />UNLESS NOTED OTHERWISE. <br />2. <br />MAINTAIN 16" FROM ADJACENT EXTERIOR WALLS. <br />CEILING HEIGHT <br />WHERE INSTALLATION IS REQUIRED ON EXTERIOR <br />WALL, PROVIDE INSULATED MOUNTING PAD FOR BASE <br />INTERIOR WALL <br />PLATE. <br />3. <br />REFRAIN FROM INSTALLING THERMOSTAT NEAR ANY <br />HEATING OR COOLING SOURCES; SUCH AS EQUIPMENT, <br />WINDOWS, OR UNDER SUPPLY DIFFUSERS. <br />TRADITIONAL <br />MOUNTING HEIGHT <br />4. <br />ENSURE THERMOSTAT IS INSTALLED IN CORRECT <br />ORIENTATION AND ACCORDING TO ALL <br />ADA COMPLIANT <br />MANUFACTURER INSTALLATION INSTRUCTIONS. <br />MOUNTING HEIGHT <br />5. <br />COORDINATE FINAL LOCATION WITH IN FIELD <br />CONDITIONS, MAINTAIN CLEARANCE FROM NEARBY <br />SWITCHES AND OTHER DEVICES AS NEEDED. <br />FINISHED FLOOR <br />THERMOSTAT MOUNTING DETAIL SCALEN.T.S. 7 <br />AMM 45" <br />36" <br />r1,� <br />6' T <br />FRONT SIDE <br />VIEW VIEW <br />EQUIPMENT ELEVATIONS SCALE <br />- FRONT & SIDE N.T.S. <br />EXISTING ROOF CAP WITH BIRDSCREEN <br />12" MIN, <br />ROOF CURB WITH FLASHING AND CANT STRIP <br />FLEX CONNECTION <br />BACKDRAFT DAMPER <br />SUPPORT FROM STRUCTURE ABOVE, MINIMUM <br />OR 4 STEEL ALL -THREAD RODS <br />ACOUSTICALLY INSULATED <br />HOUSING <br />EXHAUST FAN <br />INTEGRAL EXHAUST GRILLE <br />CEILING MOUNTED EXHAUST FAN DETAIL SCALE 3 <br />N.T.S. <br />NOTES: <br />1. SEE SMACNA STANDARDS FOR ADDITIONAL DETAILS. <br />2. NOT MORE THAN ONE TRANSVERSE JOINT BETWEEN HANGERS. <br />AIR FLOW <br />SEAL JOINT WITH <br />E-PDXY AND DUCT TAPE <br />1-1/2"- 26 GAUGESTRAP, 8 FT <br />GALV. SHEET. METAL STRAP <br />SUPPORT PER SMACNA. <br />GLASS FIBER DUCTWORK <br />MIN. 1", 22 GA. GALV. SHT. <br />MTL. STRAP, 8 FT O.C. MAX <br />1"X3"X1" CHANNEL. <br />INSULATED FLEX. DUCTWORK <br />SEAL JOINT WITH EPDXY <br />AND DUCT TAPE <br />INSULATED TAKE -OFF INSULATE -� <br />TOP OF ALL AIR TERMINALS <br />ADAPTER AS REQUIRED <br />RADIANT DAMPER <br />DIFFUSER <br />FIBERGLASS DUCT HANGER DETAILS I <br />SCALEN.T.S. 6 <br />X" (SEE <br />CHART) <br />CONNECT TO STRUCTURAL PER <br />MFGR'S RECOMMENDATIONS <br />ROOF MEMBRANE <br />METAL ROOF DECKING <br />STEEL JOIST <br />CONDENSING UNIT <br />INSULATE ENTIRE LENGTH OF SUCTION <br />PIPING WITH 1" CLOSED CELL <br />INSULATION OUTDOORS. COVER <br />INSULATION WITH ALUMINUM JACKET <br />OR AL CLAD AS MADE BY K-FLEX <br />ROOF MEMBRANE <br />PROVIDE ALUMINUM STAND AND ALL <br />NECESSARY MOUNTING HARDWARE AS <br />MANUFACTURED BY MIAMI TECH INC. <br />MODEL AS14 NOA# 16-060101 <br />FLASHING BY ROOF CONTRACTOR (SEAL <br />WATERTIGHT) r� <br />I <br />SUCTION PIPING <br />INSULATED WITH 3/4" <br />CLOSED CELL <br />INSULATION INDOORS <br />MOUNTED MECHANICAL UNITS <br />WIDTH OF MECHANICAL <br />UNIT (INCHES) <br />MINIMUM CLEARANCE ABOVE <br />SURFACES (INCHES) <br />< 24 <br />14 <br />25 < 36 <br />18 <br />37 < 48 <br />24 <br />49 < 60 <br />30 <br />> 60 <br />48 <br />L_ I CONDENSING UNIT MOUNTING DETAIL SCALE _ 8 <br />N.T.S. <br />DETAILS NOTE: NOT ALL DETAILS ON THIS SHEET <br />MAY APPLY TO THIS PROJECT. REFER TO PROJECT <br />MECHANICAL PLANS FOR DETAILS APPLICABLE TO <br />THIS PROJECT. <br />o <br />0 <br />m <br />� <br />LU <br />N <br />� <br />o <br />o <br />UL <br />A <br />w <br />a', <br />U <br />1n <br />0 <br />z <br />qw <br />INFINITY ENGINEERING <br />GROUP, LLC <br />1208 East Kennedy Boulevard <br />Suite 230 <br />Tampa, Florida 33602 <br />[p]: 813.434.4770 <br />[fJ: 813.445.4211 <br />www.iegroup.net <br />Cert. of Auth. No. 27889 <br />Client Name and Address <br />1201 OAKFIELD DRIVE, NO. 109 <br />BRANDON, FLORIDA 33509 <br />RICHAR MB <br />, P.E. <br />FL `R N .. 7 <br />067 <br />�. <br />,. <br />r fc <br />Date <br />J <br />v <br />LO <br />Cn <br />Cn <br />M <br />J <br />H <br />W <br />J <br />W <br />� <br />J <br />a. <br />�J <br />m <br />a <br />J <br />J <br />U) <br />2 <br />Q <br />N <br />LO <br />� <br />W <br />w <br />z <br />a <br />R <br />a <br />� <br />Project No. <br />Sheet <br />140-88.00 <br />M-003 <br />Date <br />05/03/2019 <br />Scale <br />AS NOTED <br />