Laserfiche WebLink
FOR REFERENCE ONLY <br />REFER TO SEPARATE PERMIT CAPTIVE -AIR (OR EQUAL) EXHAUST FAN, HOOD, AND <br />MAKE UP AIR UNIT PLANS FOR ADDITIONAL INFORMATION <br />unnn rATFf)PL1A1rTnAT <br />EXHAUST PLENUM <br />HOOD CONFIG. <br />HOOD <br />TAG <br />MODEL <br />LENGTH <br />COOKING <br />MUA CFM <br />AC CFM <br />HOOD <br />TOTAL <br />RISER(S) <br />END TO <br />WIDTH <br />LENG. <br />HEIGHT <br />DIA. <br />CFM <br />VEL. <br />S.P. <br />NO. <br />TEMP. <br />EXH. CFM <br />CONSTRUCTION <br />END <br />ROW <br />5424 <br />430 SS <br />1 <br />4' 6" <br />Dee <br />900 <br />4" <br />10" <br />900 <br />1650 <br />-0.551" <br />765 <br />300 <br />ALONE <br />ALONE <br />ND-2-ACPSP-F <br />Where Exposed <br />unnn rArFnRuATrnAT <br />PATENT NUMBERS <br />AC-PSP (United States) - US Patent 7963830 B2 <br />AC-PSP Wall (Canada) - CA Patent 2820509 <br />AC-PSP Island (Canada) - CA Patent 2520330 <br />_ <br />FILTER(S) <br />LIGHT(S) <br />UTILITY CABINET(S) <br />FIRE <br />HOOD <br />HOOD <br />TAG <br />WIRE <br />FIRE <br />SYSTEM <br />ELECTRICAL <br />SWITCHES <br />SYSTEM <br />HANGING <br />TYPE <br />SIZE <br />MODEL # <br />QUANTITY <br />NO. <br />TYPE <br />QTY. <br />HEIGHT <br />LENGTH <br />EFFICIENCY @ 7 MICRONS <br />QTY. <br />TYPE <br />GUARD <br />LOCATION <br />SIZE <br />PIPING <br />WGHT <br />1 <br />Captrate Solo Filter <br />3 <br />20" <br />16" <br />85% See Filter Spec. <br />2 <br />L55 Series E26 <br />NO <br />Right <br />12"x54"x24" <br />Electric Wet <br />3.0 <br />DCV-1111 <br />1 Light <br />YES <br />618 <br />Chemical <br />1 Fan <br />LBS <br />unnn nPTTnAT.C' <br />HOOD <br />NO. <br />TAG <br />OPTION <br />FIELD WRAPPER 18.00" High Front, Left, Right <br />BACKSPLASH 80.00" High X 66.00" Long 430 SS Vertical <br />RISER SENSOR INSTALL 61N PLEN <br />1 <br />LEFT VERTICAL END PANEL 27" Top Width, 21" Bottom Width, 80" High Insulated 430 <br />SS <br />RIGHT VERTICAL END PANEL 27" Top Width, 21" Bottom Width, 80" High Insulated 430 <br />SS <br />PF PFnRATF. n gTTPPr.Y Pr.T+ Arrrj offq ) <br />HOOD <br />NO. <br />TAG <br />POS. <br />LENGTH <br />WIDTH <br />HEIGHT <br />TYPE <br />RISER(S) <br />WIDTH <br />LENG. <br />DIA. <br />CFM <br />S.P. <br />MUA <br />12" <br />28" <br />765 <br />0.176" <br />1 <br />Front <br />66" <br />24" <br />6" <br />AC <br />1 8" <br />16" <br />300 <br />0.082" <br />GREASE DUCT & CHIMNEY SPECIFICATIONS: <br />PROVIDE GREASE DUCT EQUAL TO CAPTIVEAIRE SYSTEMS MODEL "DW" <br />ROUND 20 GAUGE 430 STAINLESS STEEL DUCTWORK. MODEL "DW" <br />IS LISTED TO UL-1978 AND IS INSTALLED USING "V" CLAMP LOCKING <br />CONNECTIONS SEALED WITH 3M FIRE BARRIER 2000 PLUS. MODEL "DW" <br />DOES NOT REQUIRE WELDING PROVIDING IT HAS BEEN INSTALLED PER <br />THE MANUFACTURES INSTALLATION GUIDE. <br />PROVIDE RATED ACCESS DOORS AT EVERY CHANGE IN DIRECTION AND EVERY 12, ON CENTER. PER <br />MANUFACTURES LISTING MODEL "DW" HORIZONTAL RUNS LESS THAN 75 FT. CAN BE SLOPED 1/16" PER 12"1 <br />HORIZONTAL RUNS MORE THAN 75 FT. CAN BE SLOPED 3/16" PER 12". <br />DUCT SHOULD BE SLOPED AS MUCH AS POSSIBLE TO REDUCE THE CHANCE OF GREASE ACCUMULATION IN <br />HORIZONTAL RUNS. <br />IF THE DUCT OR CHIMNEY IS WITHIN 18 INCHES OF COMBUSTIBLE MATERIAL, PROVIDE UL-2221 OR UL-103 HT <br />LISTED DOUBLE WALL GREASE DUCT OR DOUBLE WALL CHIMNEY EQUAL TO CAPTIVEAIRE SYSTEMS MODEL <br />"DW- 2R, 2R TYPE HT, 3R, OR 3Z" ROUND 20 GAUGE 430 STAINLESS INNER DUCT INSULATED WITH A 24 GAUGE <br />430 STAINLESS OUTER SHELL. <br />CAPTIVEAIRE SYSTEMS RECOMMENDS THE USE OF <br />LISTED, PRE -FABRICATED ROUND GREASE EXHAUST <br />DUCT TO REDUCE STATIC PRESSURE IN THE SYSTEM, <br />MINIMIZE INSTALLATION AND INSPECTION TIMES, AND <br />ENSURE DUCT IS LIQUID TIGHT <br />VERIFY CEILING HEIGHT <br />HEIGHT REQUIRED TO VERIFY THAT HOOD FITS SPACE AND TO SIZE THE ENCLOSURE PANELS <br />HVAC DISTRIBUTION NOTE <br />HIGH VELOCITY DIFFUSERS OR HVAC RETURNS SHOULD <br />NOT BE PLACED WITHIN TEN (10) FEET OF THE EXHAUST <br />HOOD. PERFORATED DIFFUSERS ARE RECOMMENDED. <br />CUSTOMER APPROVAL TO MANUFACTURE: <br />Approved as Noted <br />❑ <br />Approved with NO Exception Taken <br />❑ <br />Revise and Resubmit <br />❑ <br />SIGNATURE <br />Your Title Date <br />54" <br />24" <br />3" <br />SPECIFICATION: CAPTRATE GAASE-STOP SOLa FILTER <br />THE CAPTRATE GREASE -STOP SOLO FILTER IS A SINGLE -STAGE FILTER FEATURING <br />A UNIQUE S-BAFFLE DESIGN IN CONJUNCTION WITH A SLOTTED REAR BAFFLE DESIGN, <br />TO DELIVER EXCEPTIONAL FILTRATION EFFICIENCY. <br />FILTER IS STAINLESS STEEL CONSTRUCTION, AND SIZED TO FIT INTO STANDARD <br />2-INCH DEEP HOOD CHANNEL(S). <br />UNITS SHALL INCLUDE STAINLESS STEEL HANDLES AND A FASTENING DEVICE TO SECURE THE TWO <br />COMPONENTS WHEN ASSEMBLED. <br />GREASE EXTRACTION EFFICIENCY PERFORMANCE SHALL REMOVE AT LEAST 75% OF GREASE <br />PARTICLES FIVE MICRONS IN SIZE, AND 85% GREASE PARTICLES SEVEN MICRONS IN SIZE AND <br />LARGER, WITH A CORRESPONDING PRESSURE DROP NOT TO EXCEED 1.0 INCHES OF WATER GAUGE. <br />THE CAPTRATE GREASE -STOP SOLO WAS TESTED TO ASTM STANDARD ASTM F2519-05. <br />EFFICIENCY VS. PARTICLE DIAMETER PRESSURE DROP VS. FLOW RATE <br />ton 3.501 <br />80 <br />Z <br />L 60 <br />w <br />40 <br />LJ <br />U <br />20 <br />0 <br />0.1 <br />1.0 10.0 <br />PARTICLE DIAMETER (um) <br />CAPTRATE FILTERS ARE BUILT IN COMPLIANCE WITH:. <br />NFPA #96 <br />NSF STANDARD #2 <br />UL STANDARD #1046 <br />INT. MECH. CODE (IMC) <br />ULC-S649 <br />U.L. Listed L55 Series E26 Canopy Light Fixture - <br />Temp Assembly <br />16" <br />6"Nom./4' 6.00"OD <br />5'-6.00" Overall LE <br />PLAN VIEW — Hood #1 <br />4' 6.00 LONG 5424ND-2—ACPSP—F <br />ACPSP ships loose for field installation <br />1/2"- 13 TPI <br />GRADE 5 (MINIMU-A' <br />STEEL HEX NUTS <br />1/2" GRADE 5 <br />(MINIMUM) STEEL <br />FLAT WASHER <br />1/2"- 13 TPI <br />GRADE 5 (MINIMUTA] <br />STEEL ALL -THREAD <br />1/2"- 13 TPI <br />GRADE 5 (MINIMUM; <br />STEEL HEX NUT <br />1/2" GRADE 5 <br />(MINIMUM) STEEL <br />FLAT WASHER <br />,.o0 <br />0.50 <br />0A0 L <br />0 <br />500 100E 150n <br />FLOW RATE (cfm) <br />\w\ BUIIT <br />N Y� IN <br />i ACCORDANCE <br />N7TH <br />NFPA <br />C fSTLO <br />HOOD CORNER <br />HANGING ANGLE <br />AIRDWARE BY INSTALLER) <br />HOOD CORNER <br />HANGING ANGLE <br />(WEIGHT BEARING <br />ANCHOR POINT <br />FOR HOOD) <br />1/2" GRADE 5 <br />(MINIMUM) STEEL <br />FLAT WASHER <br />1/2"- 13 TPI <br />GRADE 5 (MINIMUM) <br />STEEL HEX NUTS <br />ASSEMBLY INSTRUCTIONS <br />HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 <br />(MINIMUM) ALL -THREAD. SANDWICH HANGING ANGLES AND CEILING <br />ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS <br />AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE <br />DOUBLED HEX NUT CONFIGURATION BENEATH HOOD HANGING <br />ANGLES AND ABOVE CEILING ANCHORS. MAINTAIN 1/4" OF EXPOSED <br />THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 <br />FT-LBS. <br />1/2" -13 TPI <br />GRADE 5 (MINIMUM) <br />STEEL HEX NUTS <br />1/2" GRADE 5 <br />(MINIMUM) STEEL <br />FLAT WASHER <br />1/2"- 13 TPI <br />GRADE 5 (MINIMUM) <br />STEEL ALL -THREAD <br />1/2"-13TPI <br />GRADE 5 (MINIMUM) <br />STEEL HEX NUT <br />1/2" GRADE 5 <br />(MINIMUM) STEEL ' <br />FLAT WASHER <br />FULLLENGTH <br />HANGING ANGLE <br />(HARDWARE BY INSTALLER) <br />FULL LENGTH <br />HANGING AN( <br />(WEIGHT BEA <br />ANCHOR POII <br />FOR HOOD) <br />112" GRADE 5 <br />(MINIMUM) ST <br />FLAT WASHEI <br />1/2"- 13 TPI <br />GRADE 5 (MIN...._._ <br />STEEL HEX NUT <br />ASSEMBLY INSTRUCTIONS <br />HANGING ANGLE MUST BE SUPPORTED WITH 1/2" - 13 TPI GRADE 5 <br />(MINIMUM) AL.I.-THREAD. SANDWICH HANGING ANGLES AND CEILING <br />ANCHOR POINTS WITH 1/2" GRADE 5 (MINIMUM) STEEL FLAT WASHERS <br />AND 1/2" - 13 TPI GRADE 5 (MINIMUM) HEX NUTS AS SHOWN. MUST USE <br />DOUBLED HEX NUT CONFIGURATION ABOVE CEILING ANCHORS. <br />SINGLE HEX NUT BENEATH HANGING ANGLE IS ACCEPTABLE FOR <br />FULL LENGTH HANGING ANGLES. MAINTAIN 1/4" OF EXPOSED <br />THREADS BENEATH BOTTOM HEX NUT. TORQUE ALL HEX NUTS TO 57 <br />FT-LBS. <br />REVISIONS <br />3=tlg <br />WN <br />0 IdIft <br />E <br />U <br />1cc <br />�> <br />I� a <br />��U\\ <br />V <br />I� CD <br />I J_ <br />' I <br />I I <br />Q W <br />w <br />0 <br />I rn <br />I � N <br />rn <br />�C 00 <br />t0 00 <br />� co <br />v <br />d � <br />cn <br />W <br />p„ w <br />E o <br />co <br />t0 <br />M <br />J <br />u_ <br />f6 <br />cu <br />I— <br />O <br />N <br />f0 <br />O <br />N <br />O) <br />r` <br />O <br />(v <br />_rn <br />LO <br />0 <br />0 <br />2 <br />4-0 <br />^o <br />i <br />W <br />I <br />W <br />L <br />U <br />DATE: <br />DWG.#: <br />DRAWN <br />BY: <br />SCALE: <br />3/4" = 1'—on <br />MASTER DRAWING <br />rn <br />M <br />O <br />0 <br />� <br />� <br />f- <br />�' <br />N <br />a. <br />co <br />W <br />-a <br />O <br />u <br />N <br />w <br />Z <br />INFINITY ENGINEERING <br />GRO-UP, LLC <br />1208 East Kennedy Boulevard <br />Suite 230 <br />Tampa, Florida 33602 <br />[p]: 813.434.4770 <br />[fl: 813.445.4211 <br />www.iegroup.net <br />Cert. of Auth. No. 27889 <br />Client Name and Address <br />1201 OAKFIELD DRIVE, NO. 109 <br />BRANDON, FLORIDA 33509 <br />FOR <br />REFERENCE <br />ONLY <br />LJ Q LG <br />Own\ <br />Z <br />Z <br />a <br />P. <br />04 <br />caLO <br />Ch <br />M <br />�aaM <br />J <br />vi <br />�Xa <br />�C <br />J <br />W <br />W <br />J <br />co <br />a <br />aJa <br />m <br />Q <br />� <br />Z <br />a=o <br />W <br />N <br />a <br />tV LO <br />CO <br />X <br />0 <br />O <br />c <br />(o <br />E <br />E <br />U <br />z <br />M <br />z <br />iu <br />a� <br />LL <br />o. <br />r <br />rn <br />SHEET NO. <br />1 <br />Project No. Sheet <br />140-88.00 <br />Date <br />05/03/2019 MC-00 <br />Scale <br />e <br />AS NOTED <br />