PLUMBING SPECIFICATIONS: <br />PART 1 - GENERAL <br />1.1 SUBMITTALS <br />A. PRODUCT DATA: FOR EACH TYPE OF PRODUCT <br />INDICATED. <br />PART 2 - PRODUCTS <br />2.1 PIPING MATERIALS <br />A. COMPLY WITH REQUIREMENTS IN "PLUMBING <br />PIPING SCHEDULE" ARTICLE FOR APPLICATIONS <br />OF PIPE, TUBE, AND FITTING MATERIALS, AND FOR <br />JOINING METHODS, INSULATION, AND HANGING <br />REQUIREMENTS FOR SPECIFIC SERVICES, <br />SERVICE LOCATIONS, AND PIPE SIZES. <br />2.2 VALVES <br />A. NSF COMPLIANCE: NSF 61 FOR VALVE MATERIALS <br />FOR POTABLE -WATER SERVICE. <br />B. WATER SHUTOFF SERVICE: TWO-PIECE, FULL <br />PORT, BRASS BALL VALVES WITH BRASS TRIM. <br />C. CHECK VALVES: BRASS SILENT CHECK VALVES <br />WITH NONMETALLIC DISC SUITABLE FOR <br />HORIZONTAL OR VERTICAL INSTALLATION. <br />D. FUEL GAS SHUTOFF SERVICE: TWO-PIECE, FULL <br />PORT, BRASS BALL VALVES WITH BRASS TRIM, UL <br />LISTED FOR GAS SERVICE. <br />E. FUEL GAS PRESSURE REGULATORS: <br />COMMERCIAL STYLE REGULATORS WITH <br />INTERNAL PRESSURE RELIEF VALVES. <br />2.3 HANGERS AND SUPPORTS <br />A. PROVIDE HANGERS INDICATED ON DRAWINGS. <br />B. WALL SUPPORTS <br />1. PIPING 3" AND SMALLER: STEEL RISER CLAMP. <br />C. VERTICAL SUPPORT: STEEL RISER CLAMP. <br />PART 3 - EXECUTION <br />3.1 PIPING INSTALLATION <br />A. INSTALL ESCUTCHEONS AT EACH WALL, FLOOR, <br />AND CEILING PENETRATION IN EXPOSED FINISHED <br />LOCATIONS AND WITHIN CABINETS AND <br />MILLWORK. USE DEEP PATTERN ESCUTCHEONS <br />WHERE REQUIRED TO CONCEAL PROTRUDING <br />PIPE FITTINGS. <br />B. INSTALL SLEEVES FOR PIPING PENETRATIONS OF <br />WALLS, CEILINGS, AND FLOORS. <br />C.INSTALL SLEEVE SEALS FOR PIPING <br />PENETRATIONS OF CONCRETE WALLS AND <br />SLABS. <br />D. MAKE SOLDERED JOINTS USING LEAD FREE <br />SOLDER AND A NON-CORROSIZE, PASTE -TYPE <br />FLUX. CORE SOLDER IS NOT PERMITTED SOLDER <br />SHALL BE SOLID STRING OR WIRE TYPE. WHERE <br />SOLDERED COPPER PIPING IS CONNECTED TO <br />THREADED BRASS PIPING, USE CAST BRASS <br />ADAPTOR. <br />E. PLACE PLUGS IN ENDS OF UNCOMPLETED PIPING <br />AT END OF EACH DAY OR WHEN WORK STOPS. <br />F. MINIMUM SLOPE OF HORIZONTAL DRAIN PIPING <br />SHALL BE 1/4" PER FOOT FOR PIPING 2-1/2" OR <br />LESS, 1/8" PER FOOT FOR PIPING 3" TO 6", AND <br />1/16" PER FOOT FOR PIPING 8" OR LARGER. <br />G. MAKE CHANGES IN DIRECTION IN DRAIN PIPING <br />WITH INDIVIDUAL EIGTH BENDS AND WYES. <br />H. QUARTER BENDS, SWEEPS, TEES, AND <br />COMBINATION WYE & EIGTH BEND FITTINGS ARE <br />NOT PERMITTED FOR USE ON DRAIN PIPING. <br />I. EXTEND RIGID GAS PIPING TO EXTERIOR GAS <br />APPLIANCES AND INSTALL SHUTOFF VALVE, DIRT <br />LEG, AND UNION AT EACH APPLIANCE. <br />3.2 JOINT CONSTRUCTION <br />A. REAM ENDS OF PIPES AND TUBES AND REMOVE <br />BURRS. BEVEL PLAIN ENDS OF STEEL PIPE. <br />B. REMOVE SCALE, SLAG, DIRT, AND DEBRIS FROM <br />INSIDE AND OUTSIDE OF PIPES, TUBES, AND <br />FITTINGS BEFORE ASSEMBLY. <br />C. THREADED JOINTS: THREAD PIPE WITH TAPERED <br />PIPE THREADS ACCORDING TO ASME B1.20.1. CUT <br />THREADS FULL AND CLEAN USING SHARP DIES. <br />REAM THREADED PIPE ENDS TO REMOVE BURRS <br />AND RESTORE FULL ID. JOINT PIPE FITTINGS AND <br />VALVES AS FOLLOWS: <br />1. APPLY APPROPRIATE TAPE OR THREAD <br />COMPOUND TO EXTERNAL PIPE THREADS. <br />2. DAMAGED THREADS: DO NOT USE PIPE OR <br />FITTINGS WITH THREADS THAT ARE CORRODED <br />OR DAMAGED. <br />D. DISSIMILAR -MATERIAL PIPING JOINTS: MAKE <br />JOINTS USING ADAPTERS COMPATIBLE WITH <br />MATERIALS OF BOTH PIPING SYSTEMS. <br />3.3 HANGERS AND SUPPORT INSTALLATION <br />A. SUPPORT PIPES THROUGHOUT BUILDING, BOTH <br />HORIZONTALLY AND VERTICAL IN ACCORDANCE <br />WITH REQUIREMENTS HEREIN AND AS SHOWN ON <br />THE DRAWINGS. DO NOT USE FASTENERS WHICH <br />PENETRATE THE ROOF DECK. <br />B. PROVIDE COPPER PLATED HANGERS AND <br />SUPPORTS FOR UNINSULATED COPPER PIPING. <br />PROVIDE PLASTIC INSERTS FOR UNINSULATED <br />COPPER PIPING PENETRATING METAL STUDS. <br />C. IN AREAS WITHOUT CEILINGS, SECURE <br />INSULATION SHIELDS TO INSULATION WITH <br />PRESSURE SENSITIVE TAPE AT EACH END OF <br />SHIELD. INSTALL HANGERS TO PROVIDE MINIMUM <br />PLUMBING SPECIFICATIONS: <br />'/z" CLEAR SPACE BETWEEN FINISHED COVERING <br />AND ADJACENT WORK. <br />E. PLACE A HANGER WITHIN ONE FOOT OF EACH <br />HORIZONTAL ELBOW. <br />F. SUPPORT VERTICAL PIPE RUNS AT ROOF, AT <br />FLOOR, AND AT MAXIMUM 15-FOOT INTERVALS. <br />G. SPACE SUPPORTS NOT MORE THAN FIVE FEET <br />APART AT VALVES, STRAINERS OR PIPING <br />ACCESSORIES LARGER THAN 2" <br />H. INSTALL LATERAL BRACING WITH PIPE HANGERS <br />AND SUPPORTS TO PREVENT SWAYING. <br />I. INSTALL HANGERS AND SUPPORTS TO ALLOW <br />CONTROLLED THERMAL, AND SEISMIC MOVEMENT <br />OF PIPING SYSTEMS, TO PERMIT FREEDOM OF <br />MOVEMENT BETWEEN PIPE ANCHORS, AND TO <br />FACILITATE ACTION OF EXPANSION JOINTS, <br />EXPANSION LOOPS, EXPANSION BENDS, AND <br />SIMILAR UNITS. <br />J. ADJUSTING <br />1. HANGER ADJUSTMENTS: ADJUST HANGERS TO <br />DISTRIBUTE LOADS EQUALLY ON ATTACHMENTS <br />AND TO ACHIEVE INDICATED SLOPE OF PIPE. <br />2. LOAD DISTRIBUTION: ADJUST HANGERS AND <br />SUPPORTS SO THAT PIPING LIVE AND DEAD <br />LOADS AND STRESSES FROM MOVEMENT WILL <br />NOT BE TRANSMITTED TO CONNECTED <br />EQUIPMENT. <br />3. PIPE SLOPES: ADJUST HANGERS AND <br />SUPPORTS TO PROVIDE INDICATED PIPE <br />SLOPES AND TO NOT EXCEED MAXIMUM PIPE <br />DEFLECTIONS ALLOWED BY ASME B31.9 FOR <br />BUILDING SERVICES PIPING. <br />4. TRIM EXCESS LENGTH OF CONTINUOUS - <br />THREAD HANGER AND SUPPORT RODS TO 1-1/2". <br />3.4 PIPE INSULATION INSTALLATION <br />A. INSULATE FITTINGS AND VALVES WITH <br />PREFORMED INSULATION FITTINGS WITH PVC <br />JACKET. <br />3.5 VALVE AND SPECIALTIES INSTALLATION <br />A. PROVIDE DEEP SEAL P-TRAPS FOR FLOOR DRAINS <br />AND MOP BASINS. <br />B. FOR CLEANOUTS LOCATED IN CONCEALED <br />PIPING, INSTALL CLEANOUT WALL ACCESS <br />COVERS OF TYPES INDICATED, WITH FRAME AND <br />COVER FLUSH WITH FINISHED WALL. <br />C. PROTECT DRAINS DURING CONSTRUCTION <br />PERIOD TO AVOID CLOGGING WITH DIRT OR <br />DEBRIS AND TO PREVENT DAMAGE FROM <br />TRAFFIC OR CONSTRUCTION WORK. <br />GENERAL NOTES: <br />A. PROVIDE ALL MATERIALS AND EQUIPMENT AND <br />PERFORM ALL LABOR REQUIRED TO INSTALL <br />COMPLETE AND OPERABLE PLUMBING SYSTEMS <br />AS INDICATED ON THE DRAWINGS, AS SPECIFIED <br />AND AS REQUIRED BY CODE. <br />B. CONTRACT DOCUMENT DRAWINGS FOR <br />PLUMBING WORK ARE DIAGRAMMATIC AND ARE <br />INTENDED TO CONVEY SCOPE AND GENERAL <br />ARRANGEMENT ONLY. <br />C. INSTALL ALL PLUMBING EQUIPMENT AND <br />APPURTENANCES IN ACCORDANCE WITH <br />MANUFACTURERS' RECOMMENDATIONS, <br />CONTRACT DOCUMENTS, AND APPLICABLE <br />CODES AND REGULATIONS. <br />D. PROVIDE VIBRATION ISOLATION FOR ALL <br />PLUMBING EQUIPMENT TO PREVENT <br />TRANSMISSION OF VIBRATION TO BUILDING <br />STRUCTURE. <br />E. PROVIDE VIBRATION ISOLATORS FOR ALL PIPING <br />SUPPORTS CONNECTED TO AND WITHIN 50 FEET <br />OF ISOLATED EQUIPMENT (EXCEPT AT BASE <br />ELBOW SUPPORTS AND ANCHOR POINTS) <br />THROUGHOUT MECHANICAL EQUIPMENT ROOMS. <br />DO THE SAME FOR SUPPORTS OF STEAM MAINS <br />WITHIN 50 FEET OF BOILER OR PRESSURE <br />REDUCING VALVES. <br />F. PROVIDE VIBRATION ISOLATORS FOR ALL PIPING <br />SUPPORTS OF STEAM MAINS WITHIN 50 FEET OF <br />BOILERS AND PRESSURE REDUCING VALVES. <br />G. THE LOCATION OF EXISTING UNDERGROUND <br />UTILITIES IS SHOWN IN AN APPROXIMATE WAY <br />ONLY. THE CONTRACTOR SHALL DETERMINE THE <br />EXACT LOCATION OF ALL EXISTING UTILITIES <br />BEFORE COMMENCING WORK. THE CONTRACTOR <br />SHALL PAY FOR AND REPAIR ALL DAMAGES <br />CAUSED BY FAILURE TO EXACTLY LOCATE AND <br />PRESERVE ANY AND ALL UNDERGROUND <br />UTILITIES UNLESS OTHERWISE INDICATED. <br />H. COORDINATE CONSTRUCTION OF ALL PLUMBING <br />WORK WITH ARCHITECTURAL, STRUCTURAL, <br />CIVIL, ELECTRICAL WORK, ETC., SHOWN ON <br />OTHER CONTRACT DOCUMENT DRAWINGS. <br />I. ALL TESTS SHALL BE COMPLETED BEFORE ANY <br />PLUMBING EQUIPMENT OR PIPING INSULATION IS <br />APPLIED. <br />J. LOCATE ALL TEMPERATURE, PRESSURE, AND <br />FLOW MEASURING DEVICES IN ACCESSIBLE <br />LOCATIONS WITH STRAIGHT SECTION OF PIPE <br />AND DOWNSTREAM AS RECOMMENDED BY THE <br />MANUFACTURER FOR GOOD ACCURACY. <br />GENERAL NOTES (CONT.): <br />K. WHERE TWO OR MORE ITEMS OF THE SAME TYPE <br />OF EQUIPMENT ARE REQUIRED, THE PRODUCT OF <br />ONE MANUFACTURER SHALL BE USED. <br />L. REINFORCEMENT, DETAILING, AND PLACEMENT <br />OF CONCRETE SHALL CONFORM TO ASTM 315 <br />AND ACI 318. CONCRETE SHALL CONFORM TO <br />ASTM C94. CONCRETE WORK SHALL CONFORM TO <br />ACI 318, PART ENTITLED "CONSTRUCTION <br />REQUIREMENTS." COMPRESSIVE STRENGTH IN 28 <br />DAYS SHALL BE 3,000 PSI. TOTAL AIR CONTENT OF <br />EXTERIOR CONCRETE SHALL BE BETWEEN 5 AND <br />7 PERCENT BY VOLUME. SLUMP SHALL BE <br />BETWEEN 3 AND 4 INCHES. CONCRETE SHALL BE <br />CURED FOR 7 DAYS AFTER PLACEMENT. <br />M. COORDINATE ALL EQUIPMENT CONNECTIONS <br />WITH MANUFACTURERS' CERTIFIED DRAWINGS. <br />COORDINATE AND PROVIDE ALL PIPING <br />TRANSITIONS REQUIRED FOR FINAL EQUIPMENT <br />CONNECTIONS TO FURNISHED EQUIPMENT. FIELD <br />VERIFY AND COORDINATE ALL PIPING <br />DIMENSIONS BEFORE FABRICATION. <br />N. ALL CONTROL WIRE AND CONDUIT SHALL COMPLY <br />WITH THE NATIONAL ELECTRIC CODE AND <br />DIVISION 16 OF THE SPECIFICATION. <br />O. WHERE BEAMS ARE INDICATED TO BE <br />PENETRATED WITH PIPING, COORDINATE PIPING <br />LAYOUT WITH BEAM OPENING SIZE AND OPENING <br />LOCATIONS. COORDINATION SHALL BE DONE <br />PRIOR TO CUTTING OF PIPING, OR FABRICATION <br />OF BEAMS. <br />P. THE LOCATIONS OF ALL ITEMS SHOWN ON THE <br />DRAWINGS OR CALLED FOR IN THE <br />SPECIFICATIONS THAT ARE NOT DEFINITELY <br />FIXED BY DIMENSIONS ARE APPROXIMATE ONLY. <br />THE EXACT LOCATIONS NECESSARY TO SECURE <br />THE BEST CONDITIONS AND RESULTS MUST BE <br />DETERMINED BY THE PROJECT SITE CONDITIONS <br />AND SHALL HAVE THE APPROVAL OF THE <br />ENGINEER BEFORE BEING INSTALLED. DO NOT <br />SCALE DRAWINGS. <br />Q. PROVIDE ACCESS PANELS FOR INSTALLATION IN <br />WALLS AND CEILINGS, WHERE REQUIRED, TO <br />SERVICE CONCEALED PLUMBING EQUIPMENT. <br />ACCESS PANELS SHALL BE TURNED OVER TO <br />GENERAL CONTRACTOR FOR INSTALLATION. <br />R. ALL EQUIPMENT, PIPING, ETC., SHALL BE <br />SUPPORTED AS DETAILED, SPECIFIED, AND <br />REQUIRED TO PROVIDE A VIBRATION FREE <br />INSTALLATION. <br />S. ALL PIPING AND EQUIPMENT SUPPORTED FROM <br />STRUCTURAL STEEL SHALL BE COORDINATED <br />WITH GENERAL CONTRACTOR. ALL <br />ATTACHMENTS TO STEEL BAR JOISTS, TRUSSES, <br />OR JOIST GIRDERS SHALL BE AT PANEL POINTS. <br />PROVIDE BEAM CLAMPS MEETING MSS <br />STANDARDS. WELDING TO STRUCTURAL <br />MEMBERS SHALL NOT BE PERMITTED. THE USE <br />OF C-CLAMPS SHALL NOT BE PERMITTED. <br />T. PLUMBING EQUIPMENT AND PIPING SHALL NOT BE <br />SUPPORTED FROM METAL DECK. <br />U. LOCATIONS AND SIZES OF ALL FLOOR, WALL, AND <br />ROOF OPENINGS SHALL BE COORDINATED WITH <br />ALL OTHER TRADES INVOLVED. <br />V. ALL OPENINGS IN FIRE WALLS DUE TO PIPING, <br />CONDUIT, ETC., SHALL BE FIRE STOPPED WITH A <br />PRODUCT SIMILAR TO 3M OR APPROVED EQUAL. <br />W. REFER TO TYPICAL DETAILS FOR PIPING AND <br />EQUIPMENT INSTALLATION. <br />PIPING NOTES: <br />A. PROVIDE ALL MATERIALS AND EQUIPMENT AND <br />PERFORM ALL LABOR REQUIRED TO INSTALL <br />COMPLETE AND OPERABLE PIPING SYSTEMS AS <br />INDICATED ON THE DRAWINGS, AS SPECIFIED <br />AND AS REQUIRED BY CODE. <br />B. ELEVATIONS AS SHOWN ON THE DRAWINGS ARE <br />TO THE CENTERLINE OF ALL PRESSURE PIPING <br />AND TO THE INVERT OF ALL GRAVITY PIPING. <br />C. MAINTAIN A MINIMUM OF 3'6" OF GROUND COVER <br />OVER ALL UNDERGROUND HVAC PIPING. <br />D. UNLESS OTHERWISE NOTED, ALL CHILLED WATER <br />AND HEATING WATER PIPING SHALL BE 3/4 INCH <br />SIZE. <br />E. PROVIDE AN AIR VENT AT THE HIGH POINT OF <br />EACH DROP IN THE HEATING WATER, CHILLED <br />WATER, AND OTHER CLOSED WATER PIPING <br />SYSTEMS. ALL PIPING SHALL GRADE TO LOW <br />POINTS. PROVIDE HOSE END DRAIN VALVES AT <br />THE BOTTOM OF ALL RISERS AND LOW POINTS. <br />F. UNLESS OTHERWISE NOTED, ALL PIPING IS <br />OVERHEAD, TIGHT TO UNDERSIDE OF <br />STRUCTURE OR SLAB, WITH SPACE FOR <br />INSULATION IF REQUIRED. <br />G. INSTALL PIPING SO THAT ALL VALVES, STRAINERS, <br />UNIONS, TRAPS, FLANGES, AND OTHER <br />APPURTENANCES REQUIRING ACCESS ARE <br />ACCESSIBLE. <br />H. ALL VALVES SHALL BE INSTALLED SO THAT VALVE <br />REMAINS IN SERVICE WHEN EQUIPMENT OR <br />PIPING ON EQUIPMENT SIDE OF VALVE IS <br />REMOVED. <br />PIPING NOTES (CONT.): <br />I. ALL BALANCING VALVES AND BUTTERFLY VALVES <br />SHALL BE PROVIDED WITH POSITION INDICATORS <br />AND MAXIMUM ADJUSTABLE STOPS (MEMORY <br />STOPS). <br />J. PROVIDE CHAINWHEEL OPERATORS FOR ALL <br />VALVES IN EQUIPMENT ROOMS MOUNTED <br />GREATER THAN T-0" ABOVE FLOOR LEVEL; CHAIN <br />SHALL EXTEND TO T-0" ABOVE FLOOR LEVEL. <br />K. ALL VALVES (EXCEPT CONTROL VALVES) AND <br />STRAINERS SHALL BE FULL SIZE OF PIPE BEFORE <br />REDUCING SIZE TO MAKE CONNECTIONS TO <br />EQUIPMENT AND CONTROLS. <br />L. UNIONS AND/OR FLANGES SHALL BE INSTALLED <br />AT EACH PIECE OF EQUIPMENT, IN BYPASSES, <br />AND IN LONG PIPING RUNS (100 FEET OR MORE) <br />TO PERMIT DISASSEMBLY FOR ALTERATION AND <br />REPAIRS. <br />M. PITCH STEAM PIPING DOWNWARD IN THE <br />DIRECTION OF FLOW 1 /4 INCH IN 10 FEET (1 INCH <br />IN 40 FEET) MINIMUM. PITCH ALL STEAM RETURN <br />LINES DOWNWARD IN THE DIRECTION OF <br />CONDENSATE FLOW 12 INCH PER 10 FEET (1 INCH <br />IN 20 FEET) MINIMUM. WHERE LENGTH OF BRANCH <br />LINES ARE LESS THAN 8 FEET, PITCH BRANCH <br />LINES TOWARD MAINS 12 INCH PER FOOT <br />MINIMUM. <br />N. PITCH UP ALL STEAM AND CONDENSATE <br />RUNOUTS TO RISERS AND EQUIPMENT 12 INCH <br />PER FOOT. WHERE THIS PITCH CANNOT BE <br />OBTAINED, RUNOUTS OVER 8 FEET IN LENGTH <br />SHALL BE ONE SIZE LARGER THAN NOTED. <br />O. TAP ALL BRANCH LINES FROM TOP OF STEAM <br />MAINS (45 DEGREES PREFERRED, 90 DEGREES <br />ACCEPTABLE). <br />P. PROVIDE AN END OF MAIN DRIP AT EACH RISE IN <br />THE STEAM MAIN. PROVIDE CONDENSATE DRIPS <br />AT THE BOTTOM OF ALL STEAM RISERS, <br />DOWNFED RUNOUTS TO EQUIPMENT, RADIATORS, <br />ETC., AT END OF -MAINS AND LOW POINTS, AND <br />AHEAD OF ALL PRESSURE REGULATORS, <br />CONTROL VALVES, ISOLATION VALVES, AND <br />EXPANSION JOINTS. <br />Q. ON STRAIGHT STEAM PIPING RUNS WITH NO <br />NATURAL DRAINAGE POINTS, INSTALL DRIP LEGS <br />AT INTERVALS NOT EXCEEDING 200 FEET WHERE <br />PIPE IS PITCHED DOWNWARD IN THE DIRECTION <br />OF STEAM FLOW AND A MAXIMUM OF 100 FEET <br />WHERE THE PIPE IS PITCHED UP SO THAT <br />CONDENSATE FLOW IS OPPOSITE OF STEAM <br />FLOW. <br />R. STEAM TRAPS SHALL BE MINIMUM 3/4" SIZE. <br />S. INSTALL ALL PIPING WITHOUT FORCING OR <br />SPRINGING. <br />T. ALL PIPING SHALL CLEAR DOORS AND WINDOWS. <br />U. ALL VALVES SHALL BE ADJUSTED FOR SMOOTH <br />AND EASY OPERATION. <br />V. ALL PIPING WORK SHALL BE COORDINATED WITH <br />ALL TRADES INVOLVED. OFFSETS IN PIPING <br />AROUND OBSTRUCTIONS SHALL BE PROVIDED AT <br />NO ADDITIONAL COST TO THE OWNER. <br />W. PROVIDE FLEXIBLE CONNECTIONS IN ALL PIPING <br />SYSTEMS CONNECTED TO PUMPS, CHILLERS, <br />COOLING TOWERS, AND OTHER EQUIPMENT <br />WHICH REQUIRE VIBRATION ISOLATION EXCEPT <br />WATER COILS. FLEXIBLE CONNECTIONS SHALL BE <br />PROVIDED AS CLOSE TO THE EQUIPMENT AS <br />POSSIBLE OR AS INDICATED ON THE DRAWINGS. <br />X. SLOPE REFRIGERANT PIPING ONE PERCENT IN <br />THE DIRECTION OF OIL RETURN. LIQUID LINES <br />MAY BE INSTALLED LEVEL. <br />Y. INSTALL HORIZONTAL REFRIGERANT HOT GAS <br />DISCHARGE PIPING WITH 12" PER 10 FEET <br />DOWNWARD SLOPE AWAY FROM THE <br />COMPRESSOR. <br />Z. INSTALL HORIZONTAL REFRIGERANT SUCTION <br />LINES WITH 12" PER 10 FEET DOWNWARD SLOPE <br />TO THE COMPRESSOR, WITH NO LONG TRAPS OR <br />DEAD ENDS WHICH MAY CAUSE OIL TO SEPARATE <br />FROM THE SUCTION GAS AND RETURN TO THE <br />COMPRESSOR IN DAMAGING SLUGS. <br />AA. PROVIDE LINE SIZE LIQUID INDICATORS IN MAIN <br />LIQUID LINE LEAVING CONDENSER OR RECEIVER. <br />INSTALL MOISTURE -LIQUID INDICATORS IN LIQUID <br />LINES BETWEEN FILTER DRYERS AND <br />THERMOSTATIC EXPANSION VALVES AND IN <br />LIQUID LINE TO RECEIVER. <br />AB. PROVIDE LINE SIZE STRAINER UPSTREAM OF <br />EACH AUTOMATIC VALVE. PROVIDE SHUTOFF <br />VALVE ON EACH SIDE OF STRAINER. <br />AC. PROVIDE PERMANENT FILTER DRYERS IN LOW <br />TEMPERATURE SYSTEMS AND SYSTEMS USING <br />HERMETIC COMPRESSORS. <br />AD. PROVIDE REPLACEABLE CARTRIDGE FILTER <br />DRYERS WITH THREE VALVE BYPASS ASSEMBLY <br />FOR SOLENOID VALVES, ADJACENT TO <br />RECEIVERS. <br />AE. PROVIDE REFRIGERANT CHARGING VALVE <br />CONNECTIONS IN LIQUID LINE BETWEEN <br />RECEIVER SHUTOFF VALVE AND EXPANSION <br />VALVE. <br />PLUMBING NOTES: <br />A. PROVIDE ALL MATERIALS AND EQUIPMENT AND <br />PERFORM ALL LABOR REQUIRED TO INSTALL <br />COMPLETE AND OPERABLE PLUMBING SYSTEMS <br />AS INDICATED ON THE DRAWINGS, AS SPECIFIED <br />AND AS REQUIRED BY CODE. <br />B. RUN ALL SOIL WASTE AND VENT PIPING WITH 2% <br />MINIMUM GRADE UNLESS OTHERWISE NOTED. <br />HORIZONTAL VENT PIPING SHALL BE GRADED TO <br />DRIP BACK TO THE SOIL OR WASTE PIPE BY <br />GRAVITY. <br />C. ELEVATIONS AS SHOWN ON THE DRAWINGS ARE <br />TO THE CENTERLINE OF ALL PRESSURE PIPING <br />AND TO THE INVERT OF ALL GRAVITY PIPING. <br />D. ADJUST SEWER INVERTS TO KEEP TOPS OF PIPE <br />IN LINE WHERE PIPE SIZE CHANGES. <br />E. MAINTAIN A MINIMUM OF 3'6" OF GROUND COVER <br />OVER ALL UNDERGROUND WATER MAINS AND A <br />MINIMUM OF TO" OF GROUND COVER OVER ALL <br />UNDERGROUND SEWERS AND DRAINS. <br />F. PROVIDE SHUTOFF VALVES IN ALL DOMESTIC <br />WATER PIPING SYSTEM BRANCHES IN WHICH <br />BRANCH PIPING SERVES TWO OR MORE <br />FIXTURES. <br />G. UNLESS OTHERWISE NOTED, ALL DOMESTIC COLD <br />AND HOT WATER PIPING SHALL BE 12 INCH SIZE. <br />H. UNLESS OTHERWISE NOTED, ALL PIPING IS <br />OVERHEAD, TIGHT TO UNDERSIDE OF SLAB, WITH <br />SPACE FOR INSULATION IF REQUIRED. <br />I. INSTALL PIPING SO THAT ALL VALVES, STRAINERS, <br />UNIONS, TRAPS, FLANGES, AND OTHER <br />APPURTENANCES REQUIRING ACCESS ARE <br />ACCESSIBLE. <br />J. WHERE DOMESTIC COLD AND HOT WATER PIPING <br />DROPS INTO A PIPE CHASE, THE SIZE SHOWN FOR <br />THE PIPE DROPS SHALL BE USED TO THE LAST <br />FIXTURE. <br />K. INSTALL ALL PIPING WITHOUT FORCING OR <br />SPRINGING. <br />L. ALL PIPING SHALL CLEAR DOORS AND WINDOWS. <br />M. ALL PIPING SHALL GRADE TO LOW POINTS. <br />PROVIDE HOSE END DRAIN VALVES AT THE <br />BOTTOM OF ALL RISERS AND LOW POINTS. <br />N. UNIONS AND/OR FLANGES SHALL BE INSTALLED <br />AT EACH PIECE OF EQUIPMENT, IN BYPASSES, <br />AND IN LONG PIPING RUNS (100 FEET OR MORE) <br />TO PERMIT DISASSEMBLY FOR ALTERATION AND <br />REPAIRS. <br />O. ALL VALVES SHALL BE ADJUSTED FOR SMOOTH <br />AND EASY OPERATION. <br />P. ALL VALVES (EXCEPT CONTROL VALVES) AND <br />STRAINERS SHALL BE FULL SIZE OF PIPE BEFORE <br />REDUCING SIZE TO MAKE CONNECTIONS TO <br />EQUIPMENT AND CONTROLS. <br />Q. PROVIDE CHAINWHEEL OPERATORS FOR ALL <br />VALVES IN EQUIPMENT ROOMS MOUNTED <br />GREATER THAN T-0" ABOVE FLOOR LEVEL; CHAIN <br />SHALL EXTEND TO T-0" ABOVE FLOOR LEVEL. <br />R. PROVIDE ALL PLUMBING FIXTURES AND <br />EQUIPMENT WITH ACCESSIBLE STOPS. <br />S. UNLESS OTHERWISE NOTED, DRAINS SHALL BE <br />INSTALLED AT THE LOW POINT OF ROOFS, <br />AREAWAYS, FLOORS, ETC. <br />T. PROVIDE CLEANOUTS IN SANITARY AND STORM <br />DRAINAGE SYSTEMS AT ENDS OF RUNS, AT <br />CHANGES IN DIRECTION, NEAR THE BASE OF <br />STACKS, EVERY 50 FEET IN HORIZONTAL RUNS <br />AND ELSEWHERE AS INDICATED. <br />U. ALL CLEANOUTS SHALL BE FULL SIZE OF PIPE FOR <br />PIPE SIZES 6 INCHES AND SMALLER AND SHALL BE <br />6 INCHES FOR PIPE SIZES LARGER THAN 6 <br />INCHES. <br />V. ALL BALANCING VALVES AND BUTTERFLY VALVES <br />SHALL BE PROVIDED WITH POSITION INDICATORS <br />AND MAXIMUM ADJUSTABLE STOPS (MEMORY <br />STOPS). <br />W. ALL VALVES SHALL BE INSTALLED SO THAT VALVE <br />REMAINS IN SERVICE WHEN EQUIPMENT OR <br />PIPING ON EQUIPMENT SIDE OF VALVE IS <br />REMOVED. <br />X. ALL PIPING WORK SHALL BE COORDINATED WITH <br />ALL TRADES INVOLVED. OFFSETS IN PIPING <br />AROUND OBSTRUCTIONS SHALL BE PROVIDED AT <br />NO ADDITIONAL COST TO THE OWNER. <br />Y. PROVIDE FLEXIBLE CONNECTIONS IN ALL PIPING <br />SYSTEMS CONNECTED TO PUMPS AND OTHER <br />EQUIPMENT WHICH REQUIRE VIBRATION <br />ISOLATION. FLEXIBLE CONNECTIONS SHALL BE <br />PROVIDED AS CLOSE TO THE EQUIPMENT AS <br />POSSIBLE OR AS INDICATED ON THE DRAWINGS. <br />APPLICABLE CODES: <br />• 2017 FLORIDA BUILDING CODE, BUILDING (6TH ED.) <br />• 2017 FLORIDA BUILDING CODE, PLUMBING (6TH ED.) <br />• 2017 FLORIDA BUILDING CODE, ENERGY <br />CONSERVATION (6TH ED.) <br />PLUMBING ABBREVIATIONS: <br />AP <br />ACCESS PANEL <br />BT <br />BATH TUB <br />BWV <br />BACK WATER VALVE <br />CFH <br />CUBIC FEET PER HOUR <br />CFM <br />CUBIC FEET PER MINUTE <br />CI <br />CAST IRON <br />CLDI <br />CEMENT LINED DUCTILE IRON <br />CO <br />CLEANOUT <br />CONC <br />CONCRETE <br />CID <br />CHROME PLATED <br />CTE <br />CONNECT TO EXISTING <br />CW <br />COLD WATER <br />CWR <br />COLD WATER RETURN <br />CWS <br />COLD WATER SUPPLY <br />DF <br />DRINKING FOUNTAIN <br />DIA <br />DIAMETER <br />ELEV <br />ELEVATION <br />EWC <br />ELECTRICAL WATER COOLER (DRINKING <br />FOUNTAIN) <br />FCO <br />FLOOR CLEANOUT <br />FEC <br />FIRE EXTINGUISHER CABINET <br />FHV <br />FIRE HOSE VALVE <br />FLR <br />FLOOR <br />FP <br />FIRE PROTECTION <br />FPWH <br />FREEZE PROOF WALL HYDRANT <br />FS <br />FLOW SWITCH <br />FT <br />FOOT OR FEET <br />FV <br />FLUSH VALVE <br />GALV <br />GALVANIZED <br />GCO <br />GROUND CLEAN OUT <br />GI <br />GREASE INTERCEPTOR <br />GPF <br />GALLONS PER FLUSH <br />GPM <br />GALLONS PER MINUTE <br />HC <br />HANDICAPPED <br />HW <br />HOT WATER <br />HWR <br />HOT WATER RETURN <br />HWS <br />HOT WATER SUPPLY <br />ID <br />INSIDE DIAMETER <br />INV <br />INVERT <br />IW <br />INDIRECT WASTE <br />MECH <br />MECHANICAL <br />MSB <br />MOP SERVICE BASIN <br />NC <br />NORMALLY CLOSED <br />NO <br />NORMALLY OPEN <br />OD <br />OUTSIDE DIAMETER <br />OED <br />OPEN END DRAIN <br />PIV <br />POST INDICATOR VALVE <br />PLBG <br />PLUMBING <br />PSI <br />POUNDS PER SQUARE INCH <br />RPBP <br />REDUCED PRESSURE BACKFLOW <br />PREVENTER <br />SA <br />SHOCK ABSORBER <br />SD <br />SANITARY DRAIN <br />SHWR <br />SHOWER <br />SK <br />SINK <br />SS <br />SOIL STACK / STAINLESS STEEL <br />TLT <br />TOILET <br />TS <br />TAMPER SWITCH <br />TW <br />TEMPERED WATER <br />TYP <br />TYPICAL <br />U <br />URINAL <br />V <br />VENT <br />VB <br />VACUUM BREAKER <br />VFD <br />VARIABLE FREQUENCY DRIVE <br />VS <br />VENT STACK <br />VTR <br />VENT THROUGH ROOF <br />W <br />WASTE <br />WC <br />WATER CLOSET (TOILET) <br />WH <br />WALL HYDRANT <br />WS <br />WASTE STACK <br />GENERAL DEMOLITION NOTES: <br />A. WORK SHALL BE PHASED IN SUCH A WAY THAT <br />EXISTING SERVICES SHALL REMAIN OPERATIONAL <br />DURING CONSTRUCTION. WORK SHALL BE <br />RESTRICTED TO THE AREAS BEING DISRUPTED BY <br />THE RENOVATION. <br />B. WORK MAY BE REQUIRED BEYOND AREA <br />INDICATED IN ORDER TO REMOVE ENTIRETY OF <br />SYSTEMS BEING DEMOLISHED. <br />C. EXISTING CONDITIONS WERE TAKEN FROM <br />DRAWINGS AND MAY NOT REFLECT EXACT <br />"AS -BUILT" CONDITIONS. FIELD VERIFY ALL <br />EXISTING CONDITIONS PRIOR TO START OF <br />WORK. <br />D. COORDINATE DEMOLITION WITH ALL OTHER <br />DISCIPLINES AND EXISTING CONDITIONS. <br />E. GRAY CONTINUOUS LINE EQUIPMENT/FIXTURES <br />TO REMAIN UNLESS OTHERWISE NOTED. DASHED <br />EQUIPMENT TO BE REMOVED UNLESS <br />OTHERWISE NOTED. <br />F. SURFACES THAT WILL BE EXPOSED IN PROPOSED <br />SCOPE TO BE REPAIRED AND PATCHED <br />ACCORDING TO PROPOSED PLANS. <br />PLUMBING DRAWING LIST: <br />SHEET NO. <br />TITLE <br />P-001 <br />PLUMBING SPECIFICATIONS AND NOTES <br />P-002 <br />PLUMBING LEGEND AND SCHEDULES <br />P-003 <br />PLUMBING DETAILS <br />P-004 <br />PLUMBING ISOMETRIC DIAGRAMS <br />P-100 <br />PLUMBING DEMOLITION PLAN <br />P-200 <br />PLUMBING PROPOSED PLAN <br />o� <br />co <br />a <br />LO <br />0 <br />o <br />w <br />O <br />.o <br />N <br />U <br />6 <br />z <br />INFINITY ENGINEERING <br />GROUP, LLC <br />1208 East Kennedy Boulevard <br />Suite 230 <br />Tampa, Florida 33602 <br />[p]: 813.434.4770 <br />[f]: 813.445.4211 <br />www.iegroup.net <br />Cert. of Auth. No. 27889 <br />Client Name and Address <br />1201 OAKFIELD DRIVE, NO. 109 <br />BRANDODh, FLORIDA 33509 <br />F <br />KIMQAVL, P.E. <br />Date <br />Z <br />N <br />C <br />J LL <br />w <br />NUJ <br />Z <br />Nd <br />J <br />J <br />J <br />a <br />Z <br />Q <br />V <br />cc <br />w <br />N <br />V <br />�p <br />m <br />W <br />J <br />cD <br />CO <br />0. <br />U) <br />to <br />N <br />� <br />a <br />u' <br />ca <br />Q. <br />m <br />N <br />E <br />z <br />U <br />p <br />P <br />d <br />2- <br />"Project No. Sheet ` <br />140-88.00 <br />Date P-001 <br />05/03/2019 <br />Scale <br />AS NOTED <br />