6512 Gall Blvd (8)
Zephyrhills
>
Building Department
>
Building Plans
>
6512 Gall Blvd (8)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:26:41 AM
Creation date
2/25/2025 4:13:38 PM
Metadata
Fields
Template:
Building Plans
Street #
6512
Location
Gall Blvd
Contractor
Dystra Construction
Building Plans - Permit #
21700
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EMERGENCY SIGN SHALL HAVE <br />WHITE LETTERS, <br />FUEL MINIMUM 1" IN <br />HEIGHT, ON RED <br />SHUT—OFF BACKGROUND <br />MUSHROOM TYPE SHUT-OFF BUTTON <br />IN NEMA 3R NON-METALLIC ENCLOSURE <br />W/ CLEAR HINGED COVER <br />MODEL: PILLA FS120 WITH COVER <br />INSTALL PER NEC. 514.11 AND 514.13 <br />EMERGENCY FUEL SHUT-OFF PUSHBUTTON SCALE 3 <br />N.T.S. <br />O 1/4" 1 P N L-A4 <br />3/16"I 208Y/120V 3o 4W <br />2" <br />3/16"I FED FROM MDP <br />C 3/16"I X)()()( AFC <br />— EQUIPMENT NAME AS <br />SPECIFIED ON PLANS <br />SYSTEM VOLTAGE <br />UPSTREAM EQUIPMENT <br />SUPPLYING POWER <br />AVAILABLE FAULT CURRENT <br />AT EQUIPMENT <br />INSTALL LABEL AT <br />TOP OF ENCLOSURE <br />NOTES: <br />1. ALL DISTRIBUTION EQUIPMENT SUCH AS PANELBOARDS, SWITCHBOARDS, DISCONNECTS, TRANSFORMERS, <br />ETC. SHALL BE PROVIDED WITH AN EQUIPMENT LABEL PER THE REQUIREMENTS OF THIS DETAIL. <br />2. LABELS SHALL BE 2-PLY ENGRAVED PLASTIC LAMINATE WITH BLACK TYPEFACE LETTERS. LABEL <br />BACKGROUND SHALL FOLLOW THE BELOW COLOR SCHEME: <br />A. NORMAL POWER - WHITE <br />B. UPS POWER - BLUE <br />C. LIFE SAFETY POWER - YELLOW <br />3. LABEL MATERIAL SHALL BE DURABLE, UV STABLE, RATED FOR OUTDOOR USE, AND ABRASION RESISTANT. <br />WHERE ATTACHED TO NEMA 4X EQUIPMENT, LABELS SHALL IN ADDITION BE CHEMICAL RESISTANT. <br />4. LABELS SHALL BE PERMANENTLY ATTACHED TO ENCLOSURE COVER WITH RIVETS UNLESS DOING SO <br />COMPROMISES ITS NEMA / IP RATING. LABELS FOR ENCLOSURES WITH WELDED SEAMS AND GASKETED <br />DOORS SUCH AS THOSE RATED NEMA 12 OR NEMA 4 SHALL BE INSTALLED USING PERMANENT WEATHER-, <br />UV-, AND TEMPERATURE -RESISTANT DOUBLE -SIDED MOUNTING TAPE ONLY. <br />5. A SUBMITTAL WITH A COMPLETE LIST OF EQUIPMENT LABELS SHALL BE PROVIDED FOR ENGINEER <br />APPROVAL PRIOR TO ORDERING. <br />6. LABELS SHALL INDICATE NO LESS THAN THE FOLLOWING: <br />A. EQUIPMENT NAME <br />B. THE NOMINAL SYSTEM VOLTAGE WHICH SAID EQUIPMENT IS CONNECTED TO <br />C. THE EQUIPMENT NAME SUPPLYING POWER TO SAID EQUIPMENT <br />D. THE AVAILABLE FAULT CURRENT AT SAID EQUIPMENT <br />EQUIPMENT LABEL DETAIL SCALE 6 <br />N.T.S. <br />Neutral <br />EYS CONDUIT <br />SEAL FITTING <br />UL APPROVED SEALING NO SEALING COMPOUND <br />COMPOUND MADE BY ABOVE THIS POINT <br />//— <br />MANUFATUREER OF <br />SEAL FITTING <br />PUSH CONDUCTORS AWAY <br />FROM THE FILLING OPENING & <br />FORCE THEM APART SO THEY <br />DO NOT LIE IN CONTACT WITH <br />EACH OTHER. ALONG THEIR <br />NOTE 3 LENGTH, PUSH SHREDS OF <br />PACKING AWAY FROM THE <br />APPROX 1/2" CONDUCTOR TO PREVENT <br />GAS LEAKAGE PATHS <br />PACKED FIBER DAMS NO I H NO FIBER OR SEALING <br />COMPOUND BELOW <br />SEAL -OFF LOCATION <br />1. PROVIDE EXPLOSION PROOF SEALS -OFFS IN ACCORDANCE WITH ARTICLES 500,501 AND 514 <br />(CLASS 1, DIVISION 1 & 2) OF THE 2011 NEC. TYPICAL FOR ALL CONDUITS IN CLASS 1 LOCATIONS, <br />INCLUDING LOW VOLTAGE CONDUITS. <br />2. CONDUIT FILL SHALL NOT EXCEED 25% OF SEAL -OFF AS PER NEC. 501.15(C)(6) <br />3. THE THICKNESS OF THE SEALING COMPOUND SHALL BE MINIMUM THE TRADE SIZE OF THE <br />SEALING FITTING AND NO LESS THAN 5/8". <br />Wht WATTSTOPPER Red <br />POWER <br />Blk PACK Red <br />BZ-250 <br />SEA -OFF DETAIL SCALE <br />L- 2 <br />N.T.S. <br />LOCAL OFF SWITCH <br />INCLUDED WITH <br />WALK-IN COOLER <br />PACKAGE <br />WIC/BEER CAVE LIGHTS <br />,c F Isolated Relay <br />1 <br />Normally Closed <br />• 1-Bm <br />Common <br />• 2-Red <br />Norlly On <br />L —maOpen_ _ _ — — _ <br />• 3-Orn <br />_ — _ J WATTSTOPPER <br />Control Output <br />4-Ylw CB-100 <br />Common <br />5-Grn <br />Light Level Output <br />• 6-Blu <br />+24VDC <br />7-Vio <br />Common <br />8-Gry <br />r Isolated Relay <br />1 <br />Normally Closed <br />• 1-Bm <br />Common <br />• 2-Red <br />L Normally Open_ _ <br />_• 3-Orn _ J WATTSTOPPER <br />Control Output <br />4-Ylw CB_100 <br />Common <br />5-Grn <br />Light Level Output <br />• 6-Blu <br />+24VDC <br />7-Vio <br />Common <br />8-Gry <br />BEER CAVE / WALK-IN COOLER <br />SCALE <br />5 <br />N.T.S. <br />LIGHTING CONTROL DIAGRAM <br />NOTES: <br />1. <br />REMOTE CONDENSING UNIT RACK IS TYPICAL. <br />COORDINATE WITH GC AND MECHANICAL CONTRACTOR <br />FOR SITE SPECIFIC RACK. <br />2. <br />COORDINATE FINAL LOCATION OF DISCONNECT SWITCH <br />° <br />MECHANICAL UNIT <br />AND RECEPTACLE WITH MECHANICAL CONTRACTOR IN <br />FIELD. ELECTRICAL INSTALLATION SHALL BE SECURELY <br />FASTENED TO MEET THE RESPECTIVE WIND SPEED FOR <br />THE LOCATION IN WHICH IT IS INSTALLED. <br />3. <br />PROVIDE ROOF BOOT TYPE FLASHING FOR ALL CONDUIT <br />PENETRATIONS. COORDINATE PENETRATIONS WITH <br />ROOFING CONTRACTOR IN FIELD. <br />4. <br />CONDUIT STUP-UP THROUGH ROOF SHALL BE RIGID <br />° <br />'x 0 s <br />METALLIC CONDUIT OR INTERMEDIATE METALLIC <br />CONDUIT. STUB -UP SHALL BE SECURED TO ROOF <br />GFCI MAINTENANCE <br />RECEPTACLE WITH <br />METALLIC <br />WEATHERPROOF <br />WHILE-N-USE COVER <br />LIQUIDTIGHT FLEXIBLE <br />METALLIC CONDUIT <br />STRUCTURE BELOW AND SHALL EXTEND BEYOND ROOF <br />BOOT TYPE FLASHING. FLEXIBLE CONDUIT SHALL NOT <br />�^ MECHANICAL PASS THROUGH ROOF BOOT TYPE FLASHING. <br />EQUIPMENT RACK 5. ALL MOUNTING HARDWARE SHALL BE HOT DIPPED <br />° GALVANIZED STEEL WITH STAINLESS STEEL FASTENERS. <br />6. ALL PENETRATIONS INTO ENCLOSURES AND EQUIPMENT <br />SHALL BE FROM BELOW OR SIDES. NO TOP <br />PENETRATIONS. <br />7. FINAL CONNECTION FROM DISCONNECT SWITCH TO <br />MECHANICAL EQUIPMENT SHALL BE MADE WITH <br />LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT OR CONDUIT <br />0 CHASE NIPPLE. <br />NEMA-3R DISCONNECT SWITCH <br />LIQUIDTIGHT FLEXIBLE <br />METALLIC CONDUIT <br />RIGID METALLIC CONDUIT OR <br />INTERMEDIATE METALLIC CONDUIT <br />ROOF JOISTS <br />1/4°I CAUTION SERIES COMBINATION SYSTEM <br />2" 1/4°I RATED 100,000 AMPERES. IDENTIFIED <br />1/4°I REPLACEMENT COMPONENTS REQUIRED. <br />REFER TO PANEL SCHEDULES FOR EQUIPMENT <br />SPECIFIC SERIES RATING AND PROVIDE LABEL ON <br />SAID EQUIPMENT INDICATING RESPECTIVE RATING <br />NOTES: <br />1. ALL SERIES RATED EQUIPMENT SHALL BE PROVIDED WITH A LABEL PER THE REQUIREMENTS OF THIS DETAIL. <br />2. LABEL SHALL BE PERMANENT, ADHESIVE -BACKED, UV STABLE, AND RATED FOR OUTDOOR USE. <br />3. A SUBMITTAL WITH A COMPLETE LIST OF EQUIPMENT LABELS SHALL BE PROVIDED FOR ENGINEER APPROVAL PRIOR TO ORDERING. <br />SERIES RATED EQUIPMENT LABEL DETAIL SCALE 7 <br />N.T.S. <br />ARCHITE <br />CEILI <br />LUI <br />RI <br />SC <br />TYPICAL PANELBOARD / <br />LOW VOLTAGE EQUIPMENT <br />SEAL -OFF NOT REQUIRED--NN"... <br />IF CONDUIT DOES NOT <br />ORIGINATE IN, TERMINATE <br />IN, OR PASS THROUGH <br />HAZARDOUS AREA <br />YARD LIGHT <br />HAZARDOUS AREA <br />DISPENSER (TYP. 3) <br />YARC <br />LIGH' <br />LEGEND: <br />• = SEAL -OFF <br />SEAL -OFF NOT REQUIRED <br />IF CONDUIT DOES NOT <br />ORIGINATE IN, TERMINATE <br />IN, OR PASS THROUGH <br />HAZARDOUS AREA <br />SEAL -OFF IS REQUIRED <br />(CONDUIT PASSES <br />THROUGH HAZARDOUS <br />AREA) <br />HT <br />NOT <br />REQUIRED <br />NOTES: <br />ELECTRICAL WIRING SHALL BE DONE IN ACCORDANCE WITH APPROVED LOCAL ELECTRICAL CODES <br />AND BY A LICENSED ELECTRICIAN. THE PUMP SHALL BE PROPERLY GROUNDED. THE RGS CONDUIT <br />SHALL BE USED WHEN INSTALLING ELECTRICAL WIRING. <br />TYPICAL SEAL -OFF REQUIREMENTS DETAIL SCALE 1 <br />N.T.S. <br />SIDE VIEW <br />IGE WIRE TO <br />'URE (TYP) <br />TWISTS <br />d (TYP) <br />NOTES: <br />1. REFER TO ARCHITECTURAL PLANS FOR CEILING GRID SUPPORT REQUIREMENTS. THIS DETAIL SHOWS FIXTURE SUPPORT <br />REQUIREMENTS ONLY. <br />2. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTING INSTRUCTIONS AND USING RECOMMENDED MOUNTING HARDWARE. <br />3. THERMAL INSULATION SHALL NOT BE INSTALLED ABOVE A RECESSED LUMINAIRE OR WITHIN 3" OF OF THE RECESSED LUMINAIRE'S <br />ENCLOSURES, WIRING COMPARTMENT, BALLAST, TRANSFORMER, LED DRIVER, OR POWER SUPPLY UNLESS THE LUMINAIRE IS <br />IDENTIFIED AS TYPE IC FOR INSULATION CONTACT. <br />TROFFER MOUNTING - LAY -IN CEILING SCALE _ 4 <br />N.T.S. <br />rn <br />M <br />o <br />� <br />0 <br />2 <br />� <br />m <br />H <br />w <br />a <br />y <br />c <br />O <br />g <br />U_ <br />4 <br />c <br />a <br />z° <br />INFINITY ENGINEERING <br />GROUP, LLC <br />1208 East Kennedy Boulevard <br />Suite 230 <br />Tampa, Florida 33602 <br />[p]: 813.434.4770 <br />[fJ: 813.445.4211 <br />www.iegroup.net <br />Cert. of Auth. No. 27889 <br />Client Name and Address <br />1201 OAKFIELD DRIVE, NO. 109 <br />BRANDON, FLORIDA 33509 <br />ANDREWA,M QHR E. <br />A F F O <br />CV <br />A <br />M <br />UJ <br />vi <br />J <br />~J <br />W <br />W <br />= <br />Ix <br />>_ <br />0 <br />J <br />v <br />= <br />W <br />J <br />U <br />J <br />m <br />0 <br />U <br />W <br />y <br />•v <br />N <br />i j <br />J <br />w <br />Q <br />a <br />� <br />c <br />R <br />m <br />m <br />Z <br />m <br />a�i <br />o <br />a <br />m <br />t <br />rn <br />Project No. <br />Sheet <br />140-88.00 <br />E-301 <br />Date <br />05/03/2019 <br />Scale <br />AS NOTED <br />ICE MAKER REMOTE CONDENSING UNIT DISCONNECT AND RECEPTACLE DETAIL SCALE <br />N.T.S. <br />