LEGEND: <br />METER <br />u <br />1 ALL WORK SHALL BE IN COMPLIANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL BUILDING <br />CODES, REGULATIONS, ORDINANCES AND STANDARDS INCLUDING ADA AND OR OTHER <br />HANDICAP ACCESSIBILITY CODES. <br />2. `BEN. CONTRACTOR SHALL COORDINATE WITH THE OWNER'S VENDORS REGARDING <br />SCHEDULING AND SEQUENCING OF THE WORK. <br />3. THE CONSTRUCTION NOTES AND DRAWINGS ARE SUPPLIED TO ILLUSTRATE THE DESIGN AND <br />GENERAL TYPE OF CONSTRUCTION DESIRED AND ARE INTENDED TO IMPLY THE FINEST QUALITY <br />OF CONSTRUCTION, MATERIAL AND WORKMANSHIP THROUGHOUT. <br />4. THE DRAWINGS ARE NOT TO BE SCALED. FOR INFORMATION CONCERNING EXISTING <br />CONDITIONS, ETC., VERIFICATION MUST BE DONE IN THE FIELD. LARGE SCALE DRAWINGS <br />HAVE PRECEDENCE OVER SMALL SCALE DRAWINGS. <br />5. PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION, CONTRACTOR SHALL VERIFY EXISTENCE <br />AND LOCATION OF ALL EXISTING ABOVE AND BELOW GRADE, UTILITIES, INCLUDING SANITARY <br />SEWER, STORM SEWER, WATER, GAS, ELECTRICAL, TELEPHONE, ETC. ANY DISCREPANCIES IN <br />UTILITY LOCATIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. <br />6. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL BUILDING <br />DIMENSIONS PRIOR TO BEGINNING CONSTRUCTION AND SHALL IMMEDIATELY NOTIFY THE <br />ARCHITECT OF ANY VARIANCE OR DISCREPANCY AFFECTING NEW CONSTRUCTION PRIOR TO <br />PROCEEDING WITH WORK. <br />7. CONTRACTOR SHALL PROVIDE ALL. NECESSARY BLOCKING IN WALLS FOR SUPPORT OF ALL <br />EQUIPMENT, SHELVING, ACCESSORIES, SIGNAGE, AND OTHER DEVICES REQUIRED. <br />8. ALL PENETRATIONS SHALL RECEIVE CAULKING TO SEAL ANY TYPE OF ENERGY LOSS. <br />0; 9. THE CONTRACTOR SHALL VERIFY AND COORDINATE ALL APPLICABLE DIMENSIONS OF FIXTURES <br />AND EQUIPMENT SUPPLIED AND/OR INSTALLED BY OTHERS. <br />10. UPON COMPLETION OF PROJECT, OBTAIN ALL FINAL INSPECTIONS AS REQUIRED BY LOCAL <br />JURISDICTIONS AND FURNISH OWNER WITH EVIDENCE OF ALL SUCH INSPECTIONS AND <br />CERTIFICATES OF OCCUPANCY. <br />1 1. GENERAL CONTRACTOR SHALL INCLUDE THE COST OF POWER COMPANY ELECTRICAL <br />TRANSFORMER, PAD, PRIMARY & SECONDARY CONDUITS, AND SECONDARY CABLING IN BASE <br />81D. <br />12. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE OWNER'S VENDORS ON SITE <br />DURING CONSTRUCTION. <br />13. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SET-UP AND COORDINATION OF ALL THE <br />UTILITY SERVICES FOR THE PROJECT. GENERAL. CONTRACTOR SHALL ALSO OBTAIN FINAL SITE <br />ADDRESS. <br />18. GENERAL CONTRACTOR SHALL PERFORM A TOPOGRAPHIC SURVEY PRIOR TO STARTING <br />CONSTRUCTION AND REPORT ANY DISCREPANCIES IN GRADES AS COMPARED TO EXISTING <br />GRADES INDICATED ON CIVIL DRAWINGS. SUBMIT A COPY OF TOPOGRAPHIC SURVEY TO <br />ARCHITECT AND INDICATE ANY DISCREPANCIES ON SURVEY PRIOR TO COMMENCING <br />EARTHWORK. <br />19. ALL EXTERIOR FLOOR PLAN DIMENSIONS ARE TO EXTERIOR FACE OF MASONRY UNLESS <br />OTHERWISE NOTED. ALL INTERIOR FLOOR PLAN DIMENSIONS ARE TO FACE OF FINISH UNLESS <br />OTHERWISE NOTED. <br />20, ALL PLYWOOD REFERENCES TO BE FIRE -RETARDANT TREATED PLYWOOD. <br />21. ALL SHEATHING REFERENCES TO BE FIRE -RETARDANT TREATED PLYWOOD OR <br />NON-COMBUSTIBLE GYPSUM BOARD PRODUCT. <br />22. PATCH AND REPAIR WALLS, FLOORS AND CEILING AS NEEDED. <br />2.3, G.C. TO VERIFY HVAC SYSTEM IS IN PROPER RUNNING CONDITION <br />AND CONSULT WITH OWNER AND ENGINEER IF ANY PROBLEMS. <br />24. G.C. TO VERIFY EXISTING COOLER, CONDENSER, AND EVAPORATOR <br />SYSTEM TO MAKE SURE IT IS IN PROPER RUNNING CONDITION AND <br />CONSULT WITH OWNER AND ENGINEER IF ANY PROBLEMS. <br />LEGEND: <br />r------1 <br />L_ _ — _ J WALLS OR EQUIPMENT TO BE DEMO. <br />__. EXISTING TO REMAIN. <br />NOT IN SCOPE OF WORK <br />PLAN NOTES: 0 <br />1-111 REMOVE EXISTING COUNTERTOPS & EQUIPMENT. <br />ElEXISTING FLOOR FINISH TO BE REMOVED. <br />El <br />EXISTING COOLER,DOORS TO BE REMOVED. <br />L.J EXISTING ELECTRICAL PANELS TO REMAIN. <br />ElEXISTING INTERIOR DOOR, FRAME AND HARDWARE TO REMOVED. REFER TO SHEET Al04. <br />ED <br />EXISTING EXTERIOR DOOR TO BE REMAIN, REPLACE HARDWARE IF REQUIRED. <br />L] EXISTING WALL AND STUDS TO BE REMOVED, REFER TO FLOOR PLAN SHEET A-101. <br />ClEXISTING HVAC TO BE REMAIN. <br />C] EXISTING STOREFRONT TO REMAIN. <br />�3 1, EXISTING GONDOLAS TO BE REMOVED. <br />,E EXISTING RESTROOM FIXTURE TO BE REMOVED, CAP OFF EXISTING PLUMBING. <br />E�] EXISTING CEILING AND LIGHTING TO BE REMOVED. <br />E] EXISTING HAND SINK TO BE REMOVED, CAP OFF EXISTING PLUMBING. <br />14; EXISTING SOFFIT TO BE REMOVED. <br />,11 EXISTING INTERIOR DOOR TO BE REMAIN, REPLACE HARDWARE IF REQUIRED. <br />t-1 <br />lEXISTING GAS MONITOR PANEL TO BE RELOCATED. <br />rn <br />co <br />o <br />0 <br />a� <br />m <br />� <br />o! <br />� <br />w <br />a <br />o <br />a <br />Lo <br />w <br />1-J—d <br />0 <br />Z <br />INFINITY ENGINEERING <br />GROUP, LLC <br />1208 East Kennedy Boulevard <br />Suite 230 <br />Tampa, Florida 33602 <br />[p]: 813.434.4770 <br />[f]: 813.445.4211 <br />www.iegroup.net <br />Cert. of Auth. No. 27889 <br />Client Name and Address <br />■ <br />1201 OAKFIELD DRIVE, NO. 109 <br />BRANDON, FLORIDA 33509 <br />NISI% P.E. <br />No 64 5 ' <br />- * A t �G1� <br />ST E OF •441` <br />DEMO PLAN <br />SCALE <br />Project No. <br />Sheet <br />140-88.00 <br />D — 101 <br />Date <br />05/03/2019 <br />Scale <br />AS NOTED <br />