Laserfiche WebLink
SECTION 012113 <br />THERMAL INSULATION <br />(CONTINUED) <br />2J COMPLIANCE: <br />A. ASTM C128S TYPE i, CLASS i POLYISO. <br />B. INTERNATIONAL RESIDENTIAL CODE (IRC). <br />C. INTERNATIONAL BUILDING CODE (15C) TYPE V CONSTRUCTION. <br />D. INTERNATIONAL ENERGY CONSERVATION CODE (IECC). <br />E. ASHRAE W.I. <br />F. DRJ TER 1201-01. <br />G. STRUCTURAL: <br />1. ASTM E12, ASTM E564, ASTM 2126 AND 65CRI SINGLE ELEMENT LATERAL LOAD <br />TESTING. <br />H. TESTED PER NFPA 286 TO COMPLY WITH iCC-ES AC12 APPENDIX B <br />I. WATER -RESISTIVE BARRIER (WRB) PER AC11 (ASTM E331, AATCC TEST METHOD 121) <br />J. AiR BARRIER MATERIAL PER ASTM E2118 <br />K. 1,2,3 OR 4 HOUR FIRE RATED ASSEMBLIES AS SHOWN IN THE UL FIRE RESISTANCE <br />DIRECTORY: <br />1. DESIGN NO: U026, U326, U330, U354, U424, U460, UW2, UW4, UW5, U806, UW1, <br />V454, V499 <br />22 DENSITY (NOMINAL) IN ACCORDANCE WITH ASTM D1622: 2.0 PCF. <br />23 COMPRESSIVE STRENGTH iN ACCORDANCE WITH ASTM 01621: 20 PSI. <br />2.4 FLAME SPREAD IN ACCORDANCE WiTH ASTM E84: 15 OR LESS. <br />2B SMOKE DEVELOPED IN ACCORDANCE WITH ASTM E84: 450 OR LESS. <br />2.6 WATER VAPOR TRANSMISSION IN ACCORDANCE WITH ASTM E96: LESS THAN 003 <br />PERKS. <br />2.1 WATER ABSORPTION IN ACCORDANCE WITH ASTM C209: LESS THAN 02 PERCENT BY <br />VOLUME. <br />2.8 DIMENSIONAL STABILITY IN ACCORDANCE WITH ASTM D2126: LESS THAN 2 PERCENT <br />LINEAR CHANGE. <br />2.9 AIR PERMEANCE IN ACCORDANCE WITH ASTM E2118: LESS THAN 002 L/(SM2) <br />2.10 SERVICE TEMPERATURE: -40 DEGREE F TO +250 DEGREE F (-38 DEGREE C TO 121 <br />DEGREE C). <br />2.11 THICKNESS: 05 INCHES (13MM). <br />A. THERMAL RESISTANCE (R). 32. <br />2.12 THICKNESS: 0.15 INCHES (VIM). <br />A. THERMAL RESISTANCE (R)- 5.0. <br />2.13 THICKNESS: 1.0 INCHES (25MM). <br />A THERMAL RESISTANCE (R): 6fd. <br />PRODUCT DATA SHEET 2 - THERMASHEATH-3: CLOSED -CELL POLYiSOCYANURATE <br />INSULATION WITH REINFORCED FOIL FACER ON EACH SiDE. <br />2J COMPLIANCE: <br />A. ASTM C128S TYPE I, CLASS 1 <br />B. ASHRAE W.I. <br />C. INTERNATIONAL ENERGY CONSERVATION CODE (IECC). <br />D. INTERNATIONAL BUILDING CODE (IBC) SECTION 2603, FOAM PLASTIC. <br />E. DPW TER 13OS-03. <br />F. ESR-1864, ICC EVALUATION SERVICE. <br />G. MiAMi-DADE COUNTY PRODUCT CONTROL APPROVED. <br />H. RR 25322, CiTY OF LOS ANGELES RESEARCH REPORT. <br />I. CALIFORNIA CODE OF REGULATIONS, TITLE 24. <br />J. CANADIAN CONSTRUCTION MATERIALS CENTRE EVALUATION'CCMC 13381-L <br />MANUFACTURED TO CONFORM TO CAN/ULC-S104-03 TYPE 1, CLASS 1. <br />K. AIR BARRIER MATERIAL PER ASTM E2118. <br />L. 1,2,3 OR 4 HOUR FIRE RATED ASSEMBLIES AS SHOWN iN THE UL FIRE RESISTANCE <br />DIRECTORY: <br />i. DESIGN NO: U026, U326, U330, U354, U424, U460, UW2, UW4, UW5, U906, U901, <br />V454, V4Sa <br />22 DENSITY (NOMINAL) IN ACCORDANCE WiTH ASTM DI622: 2D PCF. <br />23 COMPRESSIVE STRENGTH IN ACCORDANCE WITH ASTM D1621: 20 PSi. <br />2A FLAME SPREAD IN ACCORDANCE WITH ASTM E84: 15 OR LESS. <br />25 SMOKE DEVELOPED IN ACCORDANCE WiTH ASTM E84. 450 OR LESS. <br />2b WATER VAPOR TRANSMISSION IN ACCORDANCE WITH ASTM EW: LESS THAN 003 <br />PERMS. <br />2.1 WATER ABSORPTION IN ACCORDANCE WiTH ASTM C2M: LESS THAN 02 PERCENT BY <br />VOLUME. <br />2.8 DIMENSIONAL STABILITY IN ACCORDANCE WITH ASTM 02126: LESS THAN 2 PERCENT <br />LINEAR CHANGE. <br />2.9 AiR PER-MANCE IN ACCORDANCE WITH ASTM E2118: LESS THAN 0.02 LKSJ12) <br />2.10 SERVICE TEMPERATURE: -40 DEGREE F TO +250 DEGREE F (-3S DEGREE C TO 121 <br />DEGREE C). <br />2.11 THICKNESS: 05 INCHES (13MM). <br />A. THERMAL RESISTANCE (R).- 32. <br />2J2 THICKNESS: 0.15 INCHES (MMM). <br />A.THERKAL RESISTANCE (R): 5.0. <br />2.13 THICKNESS: 1.0 INCHES (25MM). <br />A.THERMAL RESISTANCE (R). (PD. <br />2.14 THICKNESS: 15 INCHES (38MM). <br />A.THERMAL RESISTANCE (R): 9b. <br />2.15 THICKNESS: 2.0 INCHES (51MM). <br />ATHERMAL RESISTANCE (R)- 13.1. <br />PRODUCT DATA SHEET 3 - THERMASHEATH-XP: CLOSED -CELL POLYiSOCYANURATE <br />(POLYISO) FOAM, WHICH IS BONDED ON BOTH SIDES WITH HIGHLY DURABLE, <br />EMBOSSED ALUMINUM FACERS. ONE SIDE HAS A WHITE MODIFIED ACRYLIC COATING <br />AND THE OTHER SIDE HAS A REFLECTIVE SURFACE WITH A CLEAR COATING.. <br />2.1 COMPLIANCE: <br />A.ASTM C1289 TYPE t, CLASS I <br />BJNTERNATIONAL RESIDENTIAL CODE (IRC). <br />C.INTERNATIONAL BUILDING CODE (IBC) SECTION 2603, FOAM PLASTIC. <br />D. INTERNATIONAL ENERGY CONSERVATION CODE (IECC). <br />E. ASHRAE W.I. <br />F. CALIFORNIA CODE OF REGULATIONS, TITLE 24 <br />G.AIR BARRIER MATERIAL PER ASTM E2118. <br />H.CLASS A FLAME SPREAD AND SMOKE DEVELOPED INDICES PER iBC CHAPTER 8, <br />INTERIOR FINISHES. <br />I. TESTED PER UL1115 TO COMPLY WITH IBC SECTION 2603, SPECIAL APPROVAL <br />PARAGRAPH: <br />1. UP TO 12 INCHES ON CEILINGS. <br />2. UP TO 45 INCHES ON WALLS. <br />J. 1,2,3 OR 4 HOUR FIRE RATED ASSEMBLIES AS SHOWN IN THE UL FIRE RESISTANCE <br />DIRECTORY: <br />1. DESIGN NO: U026, U326, U330, U354, U424, U460, UW2, UW4, U805, U806, UW1, <br />V454 AND V45% <br />22 DENSITY (NOMINAL) IN ACCORDANCE WITH ASTM 01622: 2.0 PCF. <br />23 COMPRESSIVE STRENGTH IN ACCORDANCE WITH ASTM 01621: 20 PSI. <br />2.4 FLAME SPREAD IN ACCORDANCE WITH ASTM E84: 25 OR LESS. <br />25 SMOKE DEVELOPED IN ACCORDANCE WITH ASTM E84: 450 OR LESS, <br />2.6 WATER VAPOR TRANSMISSION IN ACCORDANCE WITH ASTM E96: LESS THAN 003 <br />PERMS. <br />2.1 WATER ABSORPTION IN ACCORDANCE WITH ASTM C209: LESS THAN 02 PERCENT <br />BY VOLUME. <br />2.8 DIMENSIONAL STABILITY IN ACCORDANCE WITH ASTM 02126: LESS THAN 2 PERCENT <br />LINEAR CHANGE. <br />2.9 SERVICE TEMPERATURE: -40 DEGREE F TO +250 DEGREE F (-38 DEGREE C TO 121 <br />DEGREE C). <br />2JO THICKNESS: 0.15 INCHES (19MM). <br />A. THERMAL RESISTANCE (R): 5.0. <br />2JI THICKNESS: 1D INCHES (25MtK). <br />A. THERMAL RESISTANCE (R)- 6.0. <br />2.12 THICKNESS: 15 INCHES (38MM). <br />A. THERMAL RESISTANCE (R): Sk. <br />2.13 THICKNESS: 20 INCHES (51Mht). <br />A. THERMAL RESISTANCE (R): 13.1. <br />PRODUCT DATA SHEET 4 - R-MATTE PLUS-3: CLOSED -CELL POLYISOCYANURATE <br />INSULATION WITH REINFORCED FOIL FACER ON EACH SiDEt REFLECTIVE ON ONE <br />SIDE AND NON -GLARE MATTE ON THE OTHER SIDE, <br />2.1 COMPLIANCE: <br />A. ASTM C128S TYPE I, CLASS 1. <br />B. ASHRAE W.I. <br />C. INTERNATIONAL ENERGY CONSERVATION CODE (IECC). <br />D. INTERNATIONAL BUILDING CODE (IBC) SECTION 2603, FOAM PLASTIC <br />E. MIAMi-DADE COUNTY PRODUCT CONTROL APPROVED. <br />F. CALIFORNIA CODE OF REGULATIONS, TITLE 24. <br />G. AIR BARRIER MATERIAL PER ASTM E2118. <br />22 DENSITY (NOMINAL) IN ACCORDANCE WITH ASTM 01622: 2D PCF. <br />23 COMPRESSIVE STRENGTH IN ACCORDANCE WITH ASTM Di621: 20 PSi. <br />2.4 FLAME SPREAD IN ACCORDANCE WITH ASTM E84: 15 OR LESS. <br />25 SMOKE DEVELOPED IN ACCORDANCE WITH ASTM E84: 450 OR LESS. <br />2.6 WATER VAPOR TRANSMISSION IN ACCORDANCE WITH ASTM ES6: LESS THAN 03 <br />PERMS, <br />2.1 WATER ABSORPTION iN ACCORDANCE WITH ASTM C20S: LESS THAN 1 PERCENT BY <br />VOLUME. <br />2.8 DIMENSIONAL STABILITY IN ACCORDANCE WITH ASTM 02126: LESS THAN 2 PERCENT <br />LINEAR CHANGE. <br />2.9 AIR PERKEANCE IN ACCORDANCE WITH ASTM E2118: LESS THAN 0.02 L/(SM2) <br />2.10 SERVICE TEMPERATURE: -40 DEGREE F TO +250 DEGREE F (-38 DEGREE C TO 121 <br />DEGREE C). <br />2.11 THICKNESS: 05 INCHES (13MM). <br />A THERMAL RESISTANCE (R): 32. <br />2.12 THICKNESS: 0.15 INCHES (I°rIKM), <br />A. THERMAL RESISTANCE (R). 5.0. <br />2.13 THICKNESS: 1.0 INCHES (25MM). <br />A. THERMAL RESISTANCE (R): 6.0. <br />2.14 THICKNESS: 15 INCHES (38MM). <br />A THERMAL RESISTANCE (R). 9.6. <br />2.15 THICKNESS: 2.0 INCHES (51MM). <br />A THERMAL RESISTANCE (RA 13.1. <br />PRODUCT DATA SHEET 5 - DURASWEATH-3: CLOSED -CELL POLYISOCYANURATE <br />INSULATION WITH AN INORGANIC POLYMER <br />PRODUCT DATA SHEET 6 - WALL PANEL ACCESSORIES: PROVIDE COMPONENTS <br />REQUIRED FOR A COMPLETE METAL WALL PANEL ASSEMBLY INCLUDING TRIM, <br />COPINGS, FASCIAE, SPLINES, CORNER UNiTS, CLIPS, FLASHINGS, SEALANTS, <br />GASKETS, FILLERS, CLOSURE STRIPS, AND SIMILAR ITEMS. MATCH MATERIAL <br />AND FINISH OF METAL WALL PANELS, UNLESS OTHERWISE INDICATED. <br />PRODUCT DATA SHEET 1 - FABRICATION: FABRICATE AND FINISH METAL WALL PANELS <br />AND ACCESSORIES AT THE FACTORY TO GREATEST EXTENT POSSIBLE, BY <br />MANUFACTURE'S STANDARD PROCEDURES AND PROCESSES, AS NECESSARY TO <br />FULFILL INDICATED PERFORMANCE REQUIREMENTS DEMONSTRATED BY <br />LABORATORY TESTING. COMPLY WITH INDICATED PROFILES AND WITH DIMENSIONAL AND <br />STRUCTURAL REQUIREMENTS. <br />2.1 FORK PANEL LINES, BREAKS AND ANGLES TO BE SHARP AND TRUE, WITH <br />SURFACES FREE FROM WARP AND BUCKLE. <br />22 FABRICATE METAL WALL PANELS IN A MANNER THAT WOULD WEEP ANY <br />POSSIBLE CONDENSATION TO THE EXTERIOR <br />23 PROVIDE PANEL PROFILE FOR FULL LENGTH OF PANEL. <br />2.4 FABRICATE METAL WALL PANEL JOINTS iN A MANNER THAT WILL MINIMIZE NOISE <br />FROM MOVEMENTS WITHIN PANEL ASSEMBLY. <br />25 FABRICATE PANELS, AS REQUIRED TO COMPLY WITH DEFLECTION LIMITS, WITHOUT <br />THE USE OF BACKSIDE PANEL STIFFENERS. <br />2.6 FABRICATE PANELS WITH SHARPLY CUT EDGES, WiTH NO DISPLACEMENT OF FACE <br />SHEETS OR EXTERNAL EXPOSURE OF CORE MATERIAL. <br />2.1 DIMENSIONAL TOLERANCES - <br />A, LENGTH: PLUS 0315 INCH (95 MM). <br />B. WiDTH: PLUS 0.188 INCH (48 MM). <br />C. THICKNESS: PLUS OR MINUS 01d08 INCH (02 MM). <br />D. PANEL BOW: 0.8 PERCENT MAXIMUM OR PANEL LENGTH OR WIDTH. <br />E. SQUARENESS: 02 INCH (5 MM) MAXIMUM. <br />PART 3 - EXECUTION <br />SCHEDULE 0 - EXAMINATION <br />PRODUCT DATA SHEET 0 - DO NOT BEGIN INSTALLATION UNTIL SUBSTRATES HAVE <br />BEEN PROPERLY PREPARED. <br />PRODUCT DATA SHEET 1 - IF SUBSTRATE PREPARATION IS THE RESPONSIBILITY OF <br />ANOTHER INSTALLER NOTIFY ARCHITECT OF UNSATISFACTORY PREPARATION <br />BEFORE PROCEEDING. <br />SCHEDULE 1 - PREPARATION <br />PRODUCT DATA SHEET 0 - CLEAN SURFACES THOROUGHLY PRIOR TO <br />INSTALLATION. <br />PRODUCT DATA SHEET i - PREPARE SURFACES USING THE METHODS RECOMMENDED <br />BY THE MANUFACTURER FOR ACHIEVING THE BEST RESULT FOR THE SUBSTRATE <br />UNDER THE PROJECT CONDITIONS. <br />SCHEDULE 2 - INSTALLATION, GENERAL <br />PRODUCT DATA SHEET 0 - INSTALL IN ACCORDANCE WITH MAINUFACTURER'S <br />INSTRUCTIONS AND iN PROPER RELATIONSHIP WITH ADJACENT CONSTRUCTION. <br />SCHEDULE 3 - INSTALLATION, RAINSCREEN PANEL SYSTEM <br />PRODUCT DATA SHEET 0 - GENERAL: INSTALL METAL WALL PANELS IN ORIENTATION, <br />SIZES, AND LOCATIONS INDICATED ON APPROVED SHOP DRAWINGS. INSTALL <br />PANELS PERPENDICULAR TO GIRTS AND SUBGIRTS, UNLESS OTHERWISE INDICATED. <br />ANCHOR METAL WALL PANELS AND OTHER COMPONENTS OF THE WORK SECURELY <br />IN PLACE, WITH PROVISIONS FOR THERMAL AND STRUCTURAL MOVEMENT. <br />PRODUCT DATA SHEET I - INSTALL ATTACHMENT SYSTEM REQUIRED TO SUPPORT <br />WALL PANELS AND TO PROVIDE A COMPLETE WEATHERTIGHT WALL SYSTEM, <br />INCLUDING POLYISOCYANURATE SHEATHING, TAPES, FLASHING, SUBGIRTS, <br />PERIMETER EXTRUSIONS, TRACKS, PANEL CLIPS, AND ANCHOR CHANNELS AS MAY <br />BE REQUIRED. SEALANTS SHALL BE UTILIZED AT TYPICAL VERTICAL OR <br />HORIZONTAL JOINTS, WHERE APPLICABLE. PANEL JOINTS SHALL INCLUDE A SPLINE <br />FABRICATED FROM SAME ACM SYSTEM AS PANELS. <br />PRODUCT DATA SHEET 2 - INSTALLATION TOLERANCES: SHIM AND ALIGN METAL <br />WALL PANEL UNITS WITHIN INSTALLED TOLERANCE OF 1/4 INCH IN 20 FEET (6 MM <br />IN 6 M), NON -ACCUMULATIVE, ON LEVEL, PLUMB, AND LOCATION LINES AS <br />INDICATED AND WITHIN 1/8 INCH (3 MM) OFFSET OF ADJOINING FACES AND OF <br />ALIGNMENT OF MATCHING PROFILES <br />SCHEDULE 4 - PROTECTION <br />PRODUCT DATA SHEET 0 - PROTECT INSTALLED PRODUCTS UNTIL COMPLETION OF <br />PROJECT. <br />PRODUCT DATA SHEET 1 - TOUCH-UP, REPAIR OR REPLACE DAMAGED PRODUCTS <br />BEFORE SUBSTANTIAL COMPLETION. <br />SECTION 012115 <br />BATT INSULATION <br />PART GENERAL <br />IJ SUMMARY <br />ASECTiON INCLUDES: <br />I. BATT INSULATION IN EXTERIOR WALL AND ROOF ASSEMBLIES. <br />13 SUBMITTALS <br />A -SUSTAINABLE DESIGN SUBMITTALS. <br />I. RECYCLED CONTENT. <br />2. REGIONAL MATERIALS. <br />3. RAPIDLY RENEWABLE MATERIALS. <br />4. RECYCLED CONTENT <br />i)FOR PRODUCTS HAVING RECYCLED CONTENT, DOCUMENTATION INDICATING <br />PERCENTAGES BY WEIGHT OF POSTCONSUMER AND PRE CONSUMER RECYCLED <br />CONTENT. INCLUDE STATEMENT INDICATING COSTS FOR EACH PRODUCT HAVING <br />RECYCLED CONTENT. <br />IA PROJECT CONDITIONS <br />ADO NOT INSTALL UNTIL INSULATION UNTIL BUILDING IS SUBSTANTIALLY WATER AND <br />WEATHER TiGHT. <br />PART 2 PRODUCTS <br />2.1 MATERIALS <br />ATHERMAL BATT INSULATION: <br />I. TYPE: ASTM C665, GLASS Fi5ER COMPOSITION. <br />2. FACING: REINFORCED KRAFT PAPER VAPOR BARRIER ON ONE SIDE WITH <br />STAPLING FLANGES OR ALUMINUM FOIL/SCRiM)KRAFT PAPER VAPOR BARRIER ON <br />ONE SIDE WITH STAPLING FLANGES. <br />3. FREE FROM UREA -FORMALDEHYDE RESINS. <br />()INSULATION MANUFACTURED WITH 100 PERCENT ACRYLIC BINDERS AND NO <br />FORMALDEHYDE. <br />4. THERMAL RESISTANCE: <br />a. 3-i/2 INCHES THICK: R-VALUE OF 1100. <br />b. 3-5/8 INCHES THICK R-VALUE OF 13.00. <br />c. 6-1/4 INCHES THICK: R-VALUE OF ISOO. <br />d. 6-1/2 INCHES THICK: R-VALUE OF 22.0. <br />a. 8-1/2 INCHES THICK: R-VALUE OF 25.0. <br />P. S INCHES THICK: R-VALUE OF 26.0. <br />g. 10 INCHES THICK: R-VALUE OF 3000. <br />h 12 INCHES THiCK: R-VALUE OF 38.00. <br />3. TRIM AND ACCESSORIES. <br />13 SYSTEM DESCRIPTION <br />ASYSTEM CLASSIFICATION: EIMA CLASS PB, STANDARD AND HIGH IMPACT RESISTANCE. <br />BFIRE HAZARD CLASSIFICATION: MAXIMUM FLAME SPREAD/SMOKE DEVELOPED RATING <br />OF 25/450, TESTED TO ASTM E84. <br />1.4 SUBMITTALS <br />A.SUBMITTALS FOR REVIEW: <br />1. SHOP DRAWINGS: INDICATE JOINT LAYOUT AND DIMENSIONS, SYSTEM PENETRATION <br />DETAILS, AND TERMINATION DETAILS. <br />2. PRODUCT DATA: INCLUDE PRIMARY AND SECONDARY PRODUCT DESCRIPTIONS, <br />APPLICATION INSTRUCTIONS, PERFORMANCE CRITERIA, AND LIST OF SEALANTS <br />APPROVED FOR USE WITH SYSTEM. <br />3. SAMPLES: <br />a. 3 X 3 INCH FINISH COAT SAMPLES FOR ALL APPLICABLE COLORS SHOWN ON <br />DRAWINGS. <br />4. WARRANTY: SAMPLE WARRANTY FORK. <br />B.QUALITY CONTROL SUBMITTALS: <br />1. CERTIFICATES OF COMPLIANCE: <br />a. MANUFACTURER'S CERTIFICATION THAT INSTALLED SYSTEM COMPLIES WITH <br />REQUIREMENTS OF CONTRACT DOCUMENTS. <br />b. CERTIFICATE OF APPROVAL BY CODE AUTHORITIES HAVING JURISDICTION OVER <br />PROJECT. <br />c. CERTIFICATION FROM AN INDEPENDENT TESTING LABORATORY THAT SYSTEM <br />MEETS FIRE HAZARD CLASSIFICATION RECUIiRREMENTS. <br />15 QUALITY ASSURANCE <br />AFURNiSH EIFS SYSTEM COMPONENTS FROM SINGLE MANUFACTURER <br />BJNSTALLER QUALIFICATIONS: MINIMUM 5 YEARS DOCUMENTED EXPERIENCE IN WORK OF <br />THIS SECTION. <br />1.6 DELIVERY, STORAGE AND HANDLING <br />ASTORE ADHESIVES AND COATINGS IN PROTECTED, DRY AREA UNTIL USED, AT <br />TEMPERATURE PER THE MANUFACTURER'S PRODUCT SPECIFICATIONS. <br />1.1 PROJECT CONDITIONS <br />ADO NOT APPLY ADHESIVES AND COATINGS IF: <br />1. AMBIENT TEMPERATURE IS BELOW 40 DEGREES F, OR IS EXPECTED TO FALL <br />BELOW THAT TEMPERATURE WITHIN 24 HOURS AFTER APPLICATION. <br />2. RELATIVE HUMIDITY iS ABOVE 85 PERCENT AND SURFACE TEMPERATURE IS LOWER <br />THAN 5 DEGREES F BELOW DEW POINT. <br />3. WIND VELOCITY IS OVER 20 MPH. <br />lb WARRANTIES <br />A.FURNISH MANUFACTURER'S AND APPLICATOR'S SEPARATE STANDARD WARRANTY <br />PROVIDING COVERAGE AGAINST AIR AND WATER LEAKAGE THROUGH EIFS SYSTEM. <br />PART 2 PRODUCTS <br />2J MANUFACTURERS <br />AACCEPTABLE MANUFACTURERS: <br />1. DRYVIT SYSTEM, INC. (WWWDRYVIT:COM) <br />B.SUBSTITUTIONS: ALLOWED UPON APPROVAL OF CLIENT OR DESIGN PROFESSIONAL. <br />22 MATERIALS <br />A.MOISTURE BARRIER: FLUID -APPLIED TYPEt SYSTEM MANUFACTURER'S STANDARD <br />PRODUCT. <br />BADHESIVE: ACRYLIC BASEDt TYPE RECOMMENDED BY SYSTEM MANUFACTURER <br />CANISH COAT: EIMA CLASS PBt POLYMER BASE, MEDIUM TEXTURE, COLORS AS SHOWN <br />ON DRAWINGS. <br />D. RIGID INSULATION: <br />I. ASTM C518, TYPE VI, CLOSED CELL EXTRUDED POLYSTYRENE, SLOTTED ON BACK <br />SIDE FOR DRAINAGE. <br />2. EDGES: SQUARE. <br />3. MINIMUM THICKNESS: 2 INCHES. <br />4. THERMAL RESISTANCE: MINIMUM R VALUE OF 10. <br />E.REINFORCING: GLASS FIBER MESH, BALANCED OPEN WEAVE, ALKALINE RESISTANT, <br />TREATED FOR IMPROVED BOND WiTH COATING, TESTED TO ASTM E2098 AND <br />CLASSIFIED TO EIMA IMPACT CLASSIFICATION. <br />1. STANDARD IMPACT MESH: MINIMUM 45 OUNCES PER SQUARE YARD. <br />2. HIGH IMPACT MESH: MINIMUM 140 OUNCES PER SQUARE YARD. <br />3. CORNER MESH: MINIMUM 20.0 OUNCES PER SQUARE YARD. <br />23 ACCESSORIES <br />A.TRIM: <br />I. EXTRUDED PVC, PERFORATED ATTAC41ENT FLANGES, OF LONGEST PRACTICAL <br />LENGTH. <br />2. CORNER BEAD: BEADED EDGE, SIZE AND PROFILE TO SUIT APPLICATION. <br />3. CASNG BEAD: THICKNESS GOVERNED BY SYSTEM THICKNESS, SQUARE EDGE. <br />4. DRAINAGE CASING: THICKNESS GOVERNED BY SYSTEM THICKNESS, SQUARE EDGE, <br />PERFORATED FOR DRAINAGE. <br />5. CONTROL JOINT: ACCORDION PROFILE WITH MINIMUM 2 INCH FLANGES EACH SIDE, <br />WITH ATTACHMENT FLANGES. <br />BJNSULATION FASTENERS: HOT -DIP GALVANIZED OR FLUOROPOLYMER COATED STEEL <br />WITH MINIMUM 1 INCH DIAMETER WASHERS, MINIMUM 5/8 INCH PENETRATION INTO <br />FRAMING, OF TYPE RECOMMENDED BY SYSTEM MANUFACTURER <br />C.TRiM FASTENERS: HOT -DIP GALVANIZED OR FLUOROPOLYMER COATED STEEL, TYPE <br />RECOMMENDED BY SYSTEM MANUFACTURER <br />D. WATER CLEAN AND POTABLE. <br />2A MIXES <br />ABASE AND FINISH COAT: IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br />PART 3 EXECUTION <br />3.1 APPLICATION OF MOISTURE BARRIER <br />A.APPLY MOISTURE BARRIER IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br />B-APPLY MOISTURE BARRIER BY ROLLER TO CONTINUOUS AND UNIFORM COVERAGE <br />WITH MINIMUM MIL THICKNESS AS RECOMMENDED BY MANUFACTURER <br />C.0 X'IPLETELY JOINT COMPOUND APPLIED AT CRACKS, JOINTS, PERIMETER AND <br />PENETRATIONS WITH MOISTURE BARRIER <br />D. INSTALL HEAVY MESH UP TO 8 FEET ABOVE GRADE OR PAVING. <br />E.INSTALL CORNER MESH FOR MINIMUM 12 INCHES ON BOTH SIDES OF EXTERNAL <br />CORNERS. <br />F. INSTALL DRAINAGE CASING AT WALL BASE AND OVER OPENINGS IN WALLS. SEAL <br />CORNERS AND INTERSECTIONS. <br />32 APPLICATION OF INSULATION AND REINFORCING <br />AINSTALL SYSTEM IN ACCORDANCE WITH ANSI/EIMA SSA AND MANUFACTURER'S <br />INSTRUCTIONS. <br />B.ADHERE INSULATION TO SUBSTRATE WITH FULL ADHESIVE BED APPLIED USING <br />NOTCHED TROWEL, WITH DRAINAGE CHANNELS RUNNING VERTICALLY. <br />i. INSTALL INSULATION IN MOST ECONOMICAL MANNER, WITH JOINTS OFFSET JOINTS <br />FROM THOSE IN SUBSTRATE. <br />2. STAGGER END JOINTS IN ADJACENT ROWS MINIMUM 12 INCHES. <br />3. CUT PANELS TO FIT AT PERIMETER AND AROUND PENETRATIONS. <br />4. PRESS TO FULL CONTACT WITH ADHESIVE WITHOUT RESTRICTING DRAINAGE BEHIND <br />PANELS. <br />C.APPLY MINIMUM 1/16 INCH LAYER OF ADHESIVE OVER INSULATION BOARD. <br />D. FULLY EMBED REINFORCEMENT IN ADHESIVE, WRINKLE FREE. <br />E.LAP ENDS AND EDGES 2 INCHES MINIMUM. <br />F. WRAP REINFORCEMENT AND ADHESIVE AROUND INSULATION EDGE AT REVEALS, <br />CONTROL JOINTS AND WHERE SYSTEM ABUTS DISSIMILAR MATERIALS OR STOPS WITH <br />EDGE EXPOSED EXCEPT AT BOTTOM EDGES. <br />33APPLICATION OF FINISH COAT <br />A.APPLY IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br />B.WORK IN CONTINUOUS OPERATION IN EACH PANEL FORMED BY TRIM AND <br />INTERSECTIONS TO ENSURE EVEN TEXTURE. <br />C.CUT EDGES IN CLEAN AND SHARP WHERE WORK JOINS OTHER MATERIALS. <br />D. APPLY TO UNIFORM TEXTURE AND COLOR WITHOUT STREAKS, LAPS, HEAVY BUILDUPS, <br />AND MISSED ALAS. <br />E.ENSURE CONSISTENT APPLICATION AND UNIFORM APPEARANCE. <br />3A ADJUSTING <br />TOUCH UP FINISH COAT AS REQUIRED TO OBTAIN UNIFORM TEXTURE. <br />PART i - GENERAL <br />SECTION 012500 <br />WEATHER BARRIERS <br />DUPONT TM TYVEK8 THERMAWRAP TM <br />PART 3 EXECUTION 1.1 SECTION INCLUDES <br />3.1 INSTALLATION A.WEATHER BARRIER MEMBRANE (DUPONTTm TYVEKO THERMAWRAPTM) <br />ASTAPLE OR NAIL IN PLACE AT MAXIMUM 12 INCHES ON CENTER <br />B.BUTT INSULATION TO ADJACENT CONSTRUCTION. BUTT ENDS AND EDGES. B.SEAM TAPE (DUPONTTM TYVEKS METALLIZED CAPE OR DUPONTTM TYVEK® TAPE) <br />C.CARRY INSULATION AROUND PIPES, WIRING, BOXES, AND OTHER COMPONENTS. C.FLASHING (DUPONTTM FLEXWRAPTM DUPONTTM FLEXWRAPT"NF, DUPONTTm <br />D. ENSURE COMPLETE ENCLOSURE OF SPACES WITHOUT VOIDS. STRAIGHTFLASHTM, DUPONTTM STRAIGHTFLASHTM VF, AND/OR DUPONTTm THRU-WALL <br />E.APPLY WITH VAPOR BARRIER FACING TOWARDS EXTERIOR OR INTERIOR OF FLASHING) <br />STRUCTURE BASED ON LOCAL CLIMATE DESIGN REQUIREMENTS. D. FASTENERS <br />F. TAPE SEAL LAPPED FLANGES, BUTT ENDS, AND TEARS AND HOLES IN FACINGS. <br />SECTION 012400 <br />EXTERIOR INSULATION AND FINISH SYSTEM <br />PART GENERAL <br />I.i SUMMARY <br />ASECTiON INCLUDES: <br />1. MOISTURE BARRIER <br />2. COMPOSITE WALL CLADDING OF RIGID INSULATION AND APPLIED COATING. <br />1.2 SUBMITTALS <br />ARM R TO SECTION 3/401 33 00 SUBMITTAL PROCEDURES4 1/4INSERT SECTION NUMBER <br />AND TITLE16. <br />B.PRODUCT DATA: SUBMIT MANUFACTURER CURRENT TECHNICAL LITERATURE FOR EACH <br />COMPONENT. <br />C.SAMPLES. WEATHER BARRIER MEMBRANE, MINIMUM 8-1/2 INCHES BY Il INCH. <br />D. QUALITY ASSURANCE SUBMITTALS <br />1. DESIGN DATA, TEST REPORTS: PROVIDE MANUFACTURER TEST REPORTS <br />INDICATING PRODUCT COMPLIANCE WITH INDICATED REQUIREMENTS. <br />2. MANUFACTURER INSTRUCTIONS: PROVIDE MANUFACTURER'S WRITTEN INSTALLATION <br />INSTRUCTIONS. <br />3. MANUFACTURER'S FIELD SERVICE REPORTS: PROVIDE SITE REPORTS FROM <br />AUTHORIZED FIELD SERVICE REPRESENTATIVE, INDICATING OBSERVATION OF <br />WEATHER BARRIER ASSEMBLY INSTALLATION. <br />E.CLOSEOUT SUBMITTALS <br />1. REFER TO SECTION 3/401 18 00 CLOSEOUT SUBMITTALS'ib -4/41NSERT SECTION NUMBER <br />AND TITLEZ6. <br />2. WEATHER BARRIER MANUFACTURER'S WARRANTY: MANUFACTURER'S EXECUTED <br />WARRANTY FORM WITH AUTHORIZED SIGNATURES AND ENDORSEMENTS INDICATING <br />DATE OF UJEAT14ER BARRIER PURCHASE. <br />13 QUALITY ASSURANCE <br />AQUALUFiCATIONS <br />I. INSTALLER SHALL HAVE EXPERIENCE WITH INSTALLATION OF DUPONT TM TYVEK® <br />WEATHER BARRIER ASSEMBLIES UNDER SIMILAR CONDITIONS. <br />2. INSTALLATION SHALL BE IN ACCORDANCE WiTH WEATHER BARRIER <br />MANUFACTURER'S INSTALLATION GUIDELINES AND RECOMMENDATIONS. <br />3. SOURCE LIMITATIONS: PROVIDE WEATHER BARRIER AND ACCESSORY MATERIALS <br />PRODUCED BY SINGLE MANUFACTURER <br />BMOCK-UP <br />1. INSTALL MOCK-UP USING APPROVED WEATHER BARRIER ASSEMBLY INCLUDING <br />FASTENERS, FLASHING, TAPE AND RELATED ACCESSORIES PER MANUFACTURER'S <br />CURRENT PRINTED INSTRUCTIONS AND RECOMMENDATIONS. <br />a. MOCK-UP SIZE: 3/410 FEET BY 10 FEET16 3/41NSERT SIZE7b. <br />b. MOCK-UP SUBSTRATE: MATCH WALL ASSEMBLY CONSTRUCTION, INCLUDING <br />WINDOW OPENING. <br />2. CONTACT MANUFACTURER'S DESIGNATED REPRESENTATIVE PRIOR TO WEATHER <br />BARRIER ASSEMBLY INSTALLATION, TO PERFORM REQUIRED MOCK-UP VISUAL <br />INSPECTION AND ANALYSIS AS REQUIRED FOR WARRANTY. <br />C.PRE-INSTALLATION MEETING <br />I. REFER TO SECTION 3/401 31 IS PROJECT MEETINGStib 3/41NSERT SECTION NUMBER AND <br />TITLE16. <br />2. HOLD A PRE -INSTALLATION CONFERENCE, TWO WEEKS PRIOR TO START OF <br />WEATHER BARRIER INSTALLATION. ATTENDEES SHALL INCLUDE CONTRACTOR, <br />ARCHITECT, INSTALLER OWNER'S REPRESENTATIVE, AND WEATHER BARRIER <br />MANUFACTURER'S DESIGNATED REPRESENTATIVE. <br />3. REVIEW ALL RELATED PROJECT REQUIREMENTS AND SUBMITTALS, STATUS OF <br />SUBSTRATE WORK AND PREPARATION, AREAS OF POTENTIAL CONFLICT AND <br />INTERFACE, AVAILABILITY OF WEATHER BARRIER ASSEMBLY MATERIALS AND <br />COMPONENTS, INSTALLER'S TRAINING REQUIREMENTS, EQUIPMENT, FACILITIES AND <br />SCAFFOLDING, AND COORDINATE METHODS, PROCEDURES AND SEQUENCING <br />REQUIREMENTS FOR FULL AND PROPER INSTALLATION, INTEGRATION AND <br />PROTECTION. <br />1.4 DELIVERY, STORAGE AND HANDLING <br />AREFER TO SECTION 3/401 60 00 PRODUCT REMIREMENTS16 3441NSERT SECTION <br />NUMBER AND TITLET6. <br />B.DELIVER WEATHER BARRIER MATERIALS AND COMPONENTS IN MANUFACTURER'S <br />ORIGNAL, UNOPENED, UNDAMAGED CONTAINERS WITH IDENTIFICATION LABELS INTACT <br />C.STORE WEATHER BARRIER MATERIALS AS RECOMMENDED BY WEATHER BARRIER <br />MANUFACTURER <br />1.5 SCHEDULING <br />A.REVIEW REQUIREMENTS FOR SEQUENCING OF INSTALLATION OF WEATHER BARRIER <br />ASSEMBLY WITH INSTALLATION OF WINDOWS, DOORS, LOUVERS AND FLASHINGS TO <br />PROVIDE A WEATHER -TIGHT BARRIER ASSEMBLY. <br />B.SCHEDULE INSTALLATION OF WEATHER BARRIER MATERIALS AND EXTERIOR <br />CLADDING WITHIN FOUR MONTHS OF WEATHER BARRIER ASSEMBLY INSTALLATION. <br />Ib WARRANTY <br />AREFER TO SECTION 3/401 18 36 WARRANTIESZb 3/4INSERT SECTION NUMBER AND TITLE'tb. <br />B.SPECIAL MANUFACTURER'S WARRANTY <br />I. WEATHER BARRIER MANUFACTURER'S WARRANTY FOR WEATHER BARRIER FOR A <br />PERIOD OF TEN YEARS FROM DATE OF WEATHER BARRIER PURCHASE. <br />2. PRE -INSTALLATION MEETINGS AND J05SITE OBSERVATIONS BY WEATHER BARRIER <br />MANUFACTURER FOR WARRANTY ARE REQUIRED PRIOR TO ASSEMBLY <br />INSTALLATION. <br />3. MANUFACTURER'S WARRANTY AREAS: 3/40ESCRIBE SPECIFIC AREAS OF WORK <br />PROTECTED AND AREAS OF WORK EXCLUDED AS REQUIRED BY PROJECT <br />CONDITIONS%. <br />4. FOR WARRANTY DETAILS REVIEW MANUFACTURER'S PUBLISHED WARRANTY. THE <br />FOREGOING IS MERELY A BRIEF SUMMARY OF THE WARRANTY AND <br />MANUFACTURER'S OBLIGATIONS ARE LIMITED TO THOSE SET OUT IN THE WARRANTY <br />DOCUMENT. <br />PART 2 - PRODUCTS <br />2.1 MANUFACTURER <br />ADUPONTt 4411 LANCASTER PIKE, CHESTNUT RUN PLAZA 128, WILMINGTON, DE 19805t <br />I-SW-44-TYVEK (8-W35)t HTTP://UWUWZONSTRUCTION.TYVEK.COM <br />22 MATERIALS <br />ABASIS OF DESIGN: SPUNBONDED POLYOLEFIN, NON -WOVEN, NON -PERFORATED, <br />WEATHER BARRIER IS BASED UPON DUPONTTM TYVEKS THERMAW@APTm AND RELATED <br />ASSEMBLY COMPONENTS. <br />B.PERFORIMANCE CHARACTERISTICS (VALUES LISTED ARE NOMINAL VALUES MEASURED <br />BY AN ACCREDITED THIRD PARTY LAB-). <br />1. EFFECTIVE R-VALUE: R-2 (INCLUDING %" MINIMUM AIRSPACE), AS DESIGNATED ON <br />ASHRAE TABLES, ASTM HANDBOOK OF FUNDAMENTALS, CHAPTER 25- TABLE 3. <br />2. AiR PENETRATION: 0002 CFM+M AT 151 PSF, WHEN TESTED IN ACCORDANCE WITH <br />ASTM E 2118. <br />3. WATER VAPOR TRANSMISSION: 68 PERMS, WHEN TESTED IN ACCORDANCE WITH <br />ASTM <br />E S6, METHOD 5. <br />4. WATER PENETRATION RESISTANCE: 210 CM WHEN TESTED IN ACCORDANCE WITH <br />AATCC TEST METHOD 121. <br />5. BASIS WEIGHT: 25 OZ/YD2, WHEN TESTED IN ACCORDANCE WITH TAPPI TEST <br />METHOD T-410. <br />6. AiR RESISTANCE: AIR INFILTRATION AT 1EI000 SECONDS, WHEN TESTED IN <br />ACCORDANCE WITH TAPPI TEST METHOD T-460. <br />1. TENSILE STRENGTH: 29/21 1-55AN, WHEN TESTED IN ACCORDANCE WITH ASTM D 882, <br />METHOD A. <br />S. TEAR RESISTANCE: 12/1 LBS., WHEN TESTED IN ACCORDANCE WITH ASTM D 1111. <br />S. SURFACE BURNING CHARACTERISTICS: CLASS A, WHEN TESTED IN ACCORDANCE <br />WITH ASTM E 84. FLAME SPREAD: 10, SMOKE DEVELOPED: 40. <br />23 ACCESSORIES <br />SEAM TAPE. DUPONTT" TYVEK® METALLIZED TAPE OR DUPONTT" TYVEKS TAPE AS <br />DISTRIBUTED BY DUPONT. <br />AFASTENERS: <br />1. TYVEK® WRAP CAP SCREWS, AS DISTRIBUTED BY DUPONT: 1-5/8 INCH RUST <br />RESISTANT SCREW WITH 2-INC44 DIAMETER PLASTIC CAP FASTENERS. <br />AND/OR <br />2. TYVEKV WRAP CAPS, AS DISTRIBUTED BY DUPONT: 04 NAILS WITH LARGE 1-INC4 <br />PLASTIC CAP FASTENERS OR 1-INC44 CAP STAPLES. <br />AND/OR <br />3. MASONRY TAP -CON FASTENERS WITH TYVEKV WRAP CAPS AS DISTRIBUTED BY <br />DUPONT. 2-INCH DIAMETER PLASTIC CAP FASTENERS. <br />B.SEALANTS <br />I. REFER TO SECTION 3/401 S2 00 JOINT SEALANTSi6 3/41NSERT SECTION NUMBER AND <br />TITLE16. <br />OR <br />2. PROVIDE SEALANTS THAT COMPLY WITH ASTM C S20, ELASTOMERIC POLYMER <br />SEALANT TO MAINTAIN WATERTIGHT CONDITIONS. <br />3. PRODUCTS: <br />a. DUPONTTO RESIDENTIAL SEALANT <br />Iv. DUPONTT" COMMERCIAL SEALANT <br />c. SEALANTS RECOMMENDED BY THE WEATHER BARRIER MANUFACTURER <br />CADHESI VES: <br />I. PROVIDE ADHESIVE RECOMMENDED BY WEATHER BARRIER MANUFACTURER <br />2. PRODUCTS: <br />a. LIQUID NAILS® LN-10S <br />b. DENSO BUTYL LIQUID <br />c. 3M HIGH STRENGTH 80 <br />d. SIA 655 <br />a. ADHESIVES RECOMMEND BY THE WEATHER BARRIER MANUFACTURER <br />D. PRIMERS: <br />I. PROVIDE FLASHING MANUFACTURER RECOMMENDED PRIMER TO ASSIST IN <br />ADHESION BETWEEN SUBSTRATE AND FLASHING. <br />2. PRODUCTS: <br />a. 3M HiGH STRENGTH W <br />b. DENSO BUTYL SPRAY <br />c. SIA 655 <br />d. PERMAGRIP 105 <br />a. PRIMERS RECOMMENDED BY THE FLASHING MANUFACTURER <br />E.FLASHING <br />I. DUPONT- FLEXWRAP-, AS DISTRIBUTED BY DUPONT. FLEXIBLE MEMBRANE <br />FLASHING MATERIALS FOR WINDOW OPENINGS AND PENETRATIONS. <br />AND/OR <br />2. DUPONTTM FLEXWRAPTm NF, AS DISTRIBUTED BY DUPONT: FLEXIBLE MEMBRANE <br />FLASHING MATERIALS FOR WiNDOW OPENINGS AND PENETRATIONS. <br />AND/OR <br />3. DUPONT- STRAIGHTFLASHTM, AS DISTRIBUTED BY DUPONT: STRAIGHT FLASHING <br />MEMBRANE MATERIALS FOR FLASHING WINDOWS AND DOORS AND SEALING <br />PENETRATIONS SUCH AS MASONRY TIES, ETC. <br />AND/OR <br />4. DUPONTTM STRAIGHTFLASHTM VF, AS DISTRIBUTED BY DUPONT: DUAL -SIDED <br />STRAIGHT FLASHING MEMBRANE MATERIALS FOR BRICK MOLD AND NON -FLANGED <br />WINDOWS AND DOORS. <br />AND/OR <br />5. DUPONTTm THRU-WALL SURFACE ADHERED MEMBRANE WITH INTEGRATED DRIP <br />EDGE. THRU-WALL FLASHING MEMBRANE MATERIALS FOR FLASHING AT CHANGES IN <br />DIRECTION OR ELEVATION (SHELF ANGLES, FOUNDATIONS, ETC.) AND AT <br />TRANSITIONS BETWEEN DIFFERENT ASSEMBLY MATERIALS. <br />AND/OR <br />6. PFREFORMED INSIDE AND OUTSIDE CORNERS AND END DAMS AS DISTRIBUTED BY <br />DUPONT; PREFORMED THREE-DIMENSIONAL SHAPES TO COMPLETE THE FLASHING <br />SYSTEM USED IN CONJUNCTION WITH DUPONTTM THRU-WALL FLASHING. <br />PART 3 - EXECUTION <br />3.1 EXAMINATION <br />AVERIFY SUBSTRATE AND SURFACE CONDITIONS ARE IN ACCORDANCE WITH WEATHER <br />BARRIER MANUFACTURER RECOMMENDED TOLERANCES PRIOR TO INSTALLATION OF <br />WEATHER BARRIER AND ACCESSORIES. <br />32 INSTALLATION - WEATHER BARRIER <br />AINSTALL WEATHER BARRIER OVER EXTERIOR FACE OF EXTERIOR WALL SUBSTRATE IN <br />ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS <br />BJNSTALL WEATHER BARRIER PRiOR TO INSTALLATION OF WINDOWS AND DOORS. <br />C.START WEATHER BARRIER INSTALLATION AT A BUILDING CORNER LEAVING 6-12 <br />INCHES OF WEATHER BARRIER EXTENDED BEYOND CORNER TO OVERLAP. <br />D. INSTALL WEATHER BARRIER SILVER SIDE FACING AIR SPACE. <br />E.INSTALL WEATHER BARRIER IN A HORIZONTAL MANNER STARTING AT THE LOWER <br />PORTION OF T14E WALL SURFACE WITH SUBSEQUENT LAYERS INSTALLED N A <br />SHINGLING MANNER TO OVERLAP LOWER LAYERS. MAINTAIN WEATHER BARRIER <br />PLUMB AND LEVEL <br />F. SILL PLATE INTERFACE: EXTEND LOWER EDGE OF WEATHER BARRIER OVER SILL <br />PLATE INTERFACE <br />3-6 INCHES. SECURE TO FOUNDATION WITH ELASTOMERIC SEALANT AS <br />RECOMMENDED BY WEATHER BARRIER MANUFACTURER <br />G.WINDOW AND DOOR OPENINGS: EXTEND WEATHER BARRIER COMPLETELY OVER <br />OPENINGS. <br />H.OVERLAP WEATHER BARRIER <br />1. EXTERIOR CORNERS: MINIMUM 12 NCHES. <br />2. SEAMS: MINIMUM 6 INCHES. <br />I. WEATHER BARRIER ATTAC-41ENT: <br />I. ATTACH WEATHER BARRIER TO STUDS THROUGH EXTERIOR SHEATHING. SECURE <br />USING WEATHER BARRIER MANUFACTURER RECOMMEND FASTENERS, SPACE 6 -18 <br />INCHES VERTICALLY ON CENTER ALONG STUD LINE, AND 24 INCH ON CENTER <br />MAXIMUM HORIZONTALLY. <br />AND/OR <br />2. ATTACH WEATHER BARRIER TO MASONRY. SECURE USING WEATHER BARRIER <br />MANUFACTURER RECOMMEND FASTENERS, SPACE 6-I8 INCHES VERTICALLY ON <br />CENTER AND 24 INCHES MAXIMUM HORIZONTALLY. WEATHER BARRIER MAY BE <br />TEMPORARILY ATTACHED TO MASONRY USING RECOMMENDED ADHESIVE, PLACED <br />N VERTICAL STRIPS SPACED 24 INCHES ON CENTER WHEN COORDINATED ON THE <br />PROJECT SiTE. <br />J. APPLY 4 NCH BY 1 INCH PIECE OF DUPONT TM STRAiGHTFLASHTM OR WEATHER <br />BARRIER MANUFACTURER APPROVED ALTERNATE TO WEATHER BARRIER MEMBRANE <br />PRIOR TO THE INSTALLATION CLADDING ANCHORS. <br />33 SEAMING <br />A.SEAL SEAMS OF WEATHER BARRIER WITH SEAM TAPE AT ALL VERTICAL AND <br />HORIZONTAL OVERLAPPING SEAMS. <br />5-SEAL ANY TEARS OR CUTS AS RECOMMENDED BY WEATHER BARRIER <br />MANUFACTURER <br />3.4 OPENING PREPARATION <br />ACUT WEAT14ER BARRIER IN AN "-CUT" PATTERN. A MODIFIED "-CUT" IS ALSO <br />ACCEPTABLE. <br />I. CUT WEATHER BARRIER HORIZONTALLY ALONG THE BOTTOM AND TOP OF WINDOW <br />OPENING. <br />2. FROM TOP CENTER OF THE WINDOW OPENING, CUT WEATHER BARRIER VERTICALLY <br />DOWN TO SILL. <br />3. FOLD SIDE AND BOTTOM WEATHER BARRIER FLAPS INTO WINDOW OPENING AND <br />FASTEN. <br />B.CUT A HEAD FLAP AT 45-DEGREE ANGLE IN THE WEATHER BARRIER AT WINDOW HEAD <br />TO EXPOSE 8 INCHES OF SHEATHING. TEMPORARILY SECURE WEATHER BARRIER <br />FLAP AWAY FROM SHEATHING WITH TAPE. <br />35 FLASHING <br />ACUT 3/41-INC4'16 3/49-INCHli WIDE DUPONT- FLEXWRAPTMTE OR OUPONT- FLEXWRAPTM <br />NF A MINIMUM OF 12 INCHES LONGER THAN WIDTH OF SILL ROUGH OPENING. <br />B.COVER HORIZONTAL SILL BY ALIGNING DUPONTTM FLEXWRAPTM OR DUPONTTM <br />FLEXWRAPTm NF EDGE WITH INSIDE EDGE OF SILL. ADHERE TO ROUGH OPENING <br />ACROSS SILL AND UP JAMBS A MINIMUM OF 6 INCHES. SECURE FLASHING TIGHTLY <br />INTO CORNERS BY WORKING IN ALONG THE SILL BEFORE ADHERING UP THE JAMBS. <br />C.FAN DUPONTTM FLEXWRAPTm OR DUPONTTM FLEXWRAPTm NF AT BOTTOM CORNERS ONTO <br />FACE OF WALL. FIRMLY PRESS IN PLACE. MECHANICALLY FASTEN FANNED EDGES. <br />MECHANICAL FASTENING OF DUPONTTM FLEXWRAPTM NF IS NOT REQUIRED. <br />D. ON EXTERIOR, APPLY CONTINUOUS BEAD OF SEALANT TO WALL OR BACKSIDE OF <br />WINDOW MOUNTING FLANGE ACROSS JAMBS AND HEAD. DO NOT APPLY SEALANT <br />ACROSS SILL. <br />E.INSTALL WINDOW ACCORDING TO MANUFACTURER'S INSTRUCTIONS. <br />F. APPLY 4-INC44 WIDE STRIPS OF DUPONT' STRAiGHTFLASHTM AT JAMBS OVERLAPPING <br />ENTIRE MOUNTING FLANGE. EXTEND JAMB FLASHING 1-NC44 ABOVE TOP OF ROUGH <br />OPENING AND BELOW BOTTOM EDGE OF SILL FLASHING. <br />&APPLY 4-INCH WIDE STRIP OF DUPONTTM STRAIGHTFLASHTM AS HEAD FLASHING <br />OVERLAPPING THE MOUNTING FLANGE. HEAD FLASHING SHOULD EXTEND BEYOND <br />OUTSIDE EDGES OF BOTH JAMB FLASHINGS. <br />H.POSITION WEATHER BARRIER HEAD FLAP ACROSS HEAD FLASHING. ADHERE USING <br />4-INCH WIDE DUPONTTm STRAIGHTFLASHTm OVER THE 45-DEGREE SEAMS. <br />I. TAPE HEAD FLAP IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS <br />J. ON INTERIOR, INSTALL BACKER ROD IN JOINT BETWEEN FRAME OF WINDOW AND <br />FLASHED ROUGH FRAMING. APPLY SEALANT AROUND ENTIRE WINDOW TO CREATE <br />AiR SEAL. APPLY SEALANT IN ACCORDANCE WITH SEALANT MANUFACTURER'S <br />INSTRUCTIONS AND ASTM C 1193. <br />3.6 FIELD QUALITY CONTROL <br />ANOTIFY MANUFACTURER'S DESIGNATED REPRESENTATIVE TO OBTAIN 34REQUIRED'16 <br />PERIODIC OBSERVATIONS OF WEATHER BARRIER ASSEMBLY INSTALLATION. <br />3.1 PROTECTION <br />APROTECT INSTALLED WEATHER BARRIER FROM DAMAGE. <br />