SECTION 012113
<br />THERMAL INSULATION
<br />(CONTINUED)
<br />2J COMPLIANCE:
<br />A. ASTM C128S TYPE i, CLASS i POLYISO.
<br />B. INTERNATIONAL RESIDENTIAL CODE (IRC).
<br />C. INTERNATIONAL BUILDING CODE (15C) TYPE V CONSTRUCTION.
<br />D. INTERNATIONAL ENERGY CONSERVATION CODE (IECC).
<br />E. ASHRAE W.I.
<br />F. DRJ TER 1201-01.
<br />G. STRUCTURAL:
<br />1. ASTM E12, ASTM E564, ASTM 2126 AND 65CRI SINGLE ELEMENT LATERAL LOAD
<br />TESTING.
<br />H. TESTED PER NFPA 286 TO COMPLY WITH iCC-ES AC12 APPENDIX B
<br />I. WATER -RESISTIVE BARRIER (WRB) PER AC11 (ASTM E331, AATCC TEST METHOD 121)
<br />J. AiR BARRIER MATERIAL PER ASTM E2118
<br />K. 1,2,3 OR 4 HOUR FIRE RATED ASSEMBLIES AS SHOWN IN THE UL FIRE RESISTANCE
<br />DIRECTORY:
<br />1. DESIGN NO: U026, U326, U330, U354, U424, U460, UW2, UW4, UW5, U806, UW1,
<br />V454, V499
<br />22 DENSITY (NOMINAL) IN ACCORDANCE WITH ASTM D1622: 2.0 PCF.
<br />23 COMPRESSIVE STRENGTH iN ACCORDANCE WITH ASTM 01621: 20 PSI.
<br />2.4 FLAME SPREAD IN ACCORDANCE WiTH ASTM E84: 15 OR LESS.
<br />2B SMOKE DEVELOPED IN ACCORDANCE WITH ASTM E84: 450 OR LESS.
<br />2.6 WATER VAPOR TRANSMISSION IN ACCORDANCE WITH ASTM E96: LESS THAN 003
<br />PERKS.
<br />2.1 WATER ABSORPTION IN ACCORDANCE WITH ASTM C209: LESS THAN 02 PERCENT BY
<br />VOLUME.
<br />2.8 DIMENSIONAL STABILITY IN ACCORDANCE WITH ASTM D2126: LESS THAN 2 PERCENT
<br />LINEAR CHANGE.
<br />2.9 AIR PERMEANCE IN ACCORDANCE WITH ASTM E2118: LESS THAN 002 L/(SM2)
<br />2.10 SERVICE TEMPERATURE: -40 DEGREE F TO +250 DEGREE F (-38 DEGREE C TO 121
<br />DEGREE C).
<br />2.11 THICKNESS: 05 INCHES (13MM).
<br />A. THERMAL RESISTANCE (R). 32.
<br />2.12 THICKNESS: 0.15 INCHES (VIM).
<br />A. THERMAL RESISTANCE (R)- 5.0.
<br />2.13 THICKNESS: 1.0 INCHES (25MM).
<br />A THERMAL RESISTANCE (R): 6fd.
<br />PRODUCT DATA SHEET 2 - THERMASHEATH-3: CLOSED -CELL POLYiSOCYANURATE
<br />INSULATION WITH REINFORCED FOIL FACER ON EACH SiDE.
<br />2J COMPLIANCE:
<br />A. ASTM C128S TYPE I, CLASS 1
<br />B. ASHRAE W.I.
<br />C. INTERNATIONAL ENERGY CONSERVATION CODE (IECC).
<br />D. INTERNATIONAL BUILDING CODE (IBC) SECTION 2603, FOAM PLASTIC.
<br />E. DPW TER 13OS-03.
<br />F. ESR-1864, ICC EVALUATION SERVICE.
<br />G. MiAMi-DADE COUNTY PRODUCT CONTROL APPROVED.
<br />H. RR 25322, CiTY OF LOS ANGELES RESEARCH REPORT.
<br />I. CALIFORNIA CODE OF REGULATIONS, TITLE 24.
<br />J. CANADIAN CONSTRUCTION MATERIALS CENTRE EVALUATION'CCMC 13381-L
<br />MANUFACTURED TO CONFORM TO CAN/ULC-S104-03 TYPE 1, CLASS 1.
<br />K. AIR BARRIER MATERIAL PER ASTM E2118.
<br />L. 1,2,3 OR 4 HOUR FIRE RATED ASSEMBLIES AS SHOWN iN THE UL FIRE RESISTANCE
<br />DIRECTORY:
<br />i. DESIGN NO: U026, U326, U330, U354, U424, U460, UW2, UW4, UW5, U906, U901,
<br />V454, V4Sa
<br />22 DENSITY (NOMINAL) IN ACCORDANCE WiTH ASTM DI622: 2D PCF.
<br />23 COMPRESSIVE STRENGTH IN ACCORDANCE WITH ASTM D1621: 20 PSi.
<br />2A FLAME SPREAD IN ACCORDANCE WITH ASTM E84: 15 OR LESS.
<br />25 SMOKE DEVELOPED IN ACCORDANCE WiTH ASTM E84. 450 OR LESS.
<br />2b WATER VAPOR TRANSMISSION IN ACCORDANCE WITH ASTM EW: LESS THAN 003
<br />PERMS.
<br />2.1 WATER ABSORPTION IN ACCORDANCE WiTH ASTM C2M: LESS THAN 02 PERCENT BY
<br />VOLUME.
<br />2.8 DIMENSIONAL STABILITY IN ACCORDANCE WITH ASTM 02126: LESS THAN 2 PERCENT
<br />LINEAR CHANGE.
<br />2.9 AiR PER-MANCE IN ACCORDANCE WITH ASTM E2118: LESS THAN 0.02 LKSJ12)
<br />2.10 SERVICE TEMPERATURE: -40 DEGREE F TO +250 DEGREE F (-3S DEGREE C TO 121
<br />DEGREE C).
<br />2.11 THICKNESS: 05 INCHES (13MM).
<br />A. THERMAL RESISTANCE (R).- 32.
<br />2J2 THICKNESS: 0.15 INCHES (MMM).
<br />A.THERKAL RESISTANCE (R): 5.0.
<br />2.13 THICKNESS: 1.0 INCHES (25MM).
<br />A.THERMAL RESISTANCE (R). (PD.
<br />2.14 THICKNESS: 15 INCHES (38MM).
<br />A.THERMAL RESISTANCE (R): 9b.
<br />2.15 THICKNESS: 2.0 INCHES (51MM).
<br />ATHERMAL RESISTANCE (R)- 13.1.
<br />PRODUCT DATA SHEET 3 - THERMASHEATH-XP: CLOSED -CELL POLYiSOCYANURATE
<br />(POLYISO) FOAM, WHICH IS BONDED ON BOTH SIDES WITH HIGHLY DURABLE,
<br />EMBOSSED ALUMINUM FACERS. ONE SIDE HAS A WHITE MODIFIED ACRYLIC COATING
<br />AND THE OTHER SIDE HAS A REFLECTIVE SURFACE WITH A CLEAR COATING..
<br />2.1 COMPLIANCE:
<br />A.ASTM C1289 TYPE t, CLASS I
<br />BJNTERNATIONAL RESIDENTIAL CODE (IRC).
<br />C.INTERNATIONAL BUILDING CODE (IBC) SECTION 2603, FOAM PLASTIC.
<br />D. INTERNATIONAL ENERGY CONSERVATION CODE (IECC).
<br />E. ASHRAE W.I.
<br />F. CALIFORNIA CODE OF REGULATIONS, TITLE 24
<br />G.AIR BARRIER MATERIAL PER ASTM E2118.
<br />H.CLASS A FLAME SPREAD AND SMOKE DEVELOPED INDICES PER iBC CHAPTER 8,
<br />INTERIOR FINISHES.
<br />I. TESTED PER UL1115 TO COMPLY WITH IBC SECTION 2603, SPECIAL APPROVAL
<br />PARAGRAPH:
<br />1. UP TO 12 INCHES ON CEILINGS.
<br />2. UP TO 45 INCHES ON WALLS.
<br />J. 1,2,3 OR 4 HOUR FIRE RATED ASSEMBLIES AS SHOWN IN THE UL FIRE RESISTANCE
<br />DIRECTORY:
<br />1. DESIGN NO: U026, U326, U330, U354, U424, U460, UW2, UW4, U805, U806, UW1,
<br />V454 AND V45%
<br />22 DENSITY (NOMINAL) IN ACCORDANCE WITH ASTM 01622: 2.0 PCF.
<br />23 COMPRESSIVE STRENGTH IN ACCORDANCE WITH ASTM 01621: 20 PSI.
<br />2.4 FLAME SPREAD IN ACCORDANCE WITH ASTM E84: 25 OR LESS.
<br />25 SMOKE DEVELOPED IN ACCORDANCE WITH ASTM E84: 450 OR LESS,
<br />2.6 WATER VAPOR TRANSMISSION IN ACCORDANCE WITH ASTM E96: LESS THAN 003
<br />PERMS.
<br />2.1 WATER ABSORPTION IN ACCORDANCE WITH ASTM C209: LESS THAN 02 PERCENT
<br />BY VOLUME.
<br />2.8 DIMENSIONAL STABILITY IN ACCORDANCE WITH ASTM 02126: LESS THAN 2 PERCENT
<br />LINEAR CHANGE.
<br />2.9 SERVICE TEMPERATURE: -40 DEGREE F TO +250 DEGREE F (-38 DEGREE C TO 121
<br />DEGREE C).
<br />2JO THICKNESS: 0.15 INCHES (19MM).
<br />A. THERMAL RESISTANCE (R): 5.0.
<br />2JI THICKNESS: 1D INCHES (25MtK).
<br />A. THERMAL RESISTANCE (R)- 6.0.
<br />2.12 THICKNESS: 15 INCHES (38MM).
<br />A. THERMAL RESISTANCE (R): Sk.
<br />2.13 THICKNESS: 20 INCHES (51Mht).
<br />A. THERMAL RESISTANCE (R): 13.1.
<br />PRODUCT DATA SHEET 4 - R-MATTE PLUS-3: CLOSED -CELL POLYISOCYANURATE
<br />INSULATION WITH REINFORCED FOIL FACER ON EACH SiDEt REFLECTIVE ON ONE
<br />SIDE AND NON -GLARE MATTE ON THE OTHER SIDE,
<br />2.1 COMPLIANCE:
<br />A. ASTM C128S TYPE I, CLASS 1.
<br />B. ASHRAE W.I.
<br />C. INTERNATIONAL ENERGY CONSERVATION CODE (IECC).
<br />D. INTERNATIONAL BUILDING CODE (IBC) SECTION 2603, FOAM PLASTIC
<br />E. MIAMi-DADE COUNTY PRODUCT CONTROL APPROVED.
<br />F. CALIFORNIA CODE OF REGULATIONS, TITLE 24.
<br />G. AIR BARRIER MATERIAL PER ASTM E2118.
<br />22 DENSITY (NOMINAL) IN ACCORDANCE WITH ASTM 01622: 2D PCF.
<br />23 COMPRESSIVE STRENGTH IN ACCORDANCE WITH ASTM Di621: 20 PSi.
<br />2.4 FLAME SPREAD IN ACCORDANCE WITH ASTM E84: 15 OR LESS.
<br />25 SMOKE DEVELOPED IN ACCORDANCE WITH ASTM E84: 450 OR LESS.
<br />2.6 WATER VAPOR TRANSMISSION IN ACCORDANCE WITH ASTM ES6: LESS THAN 03
<br />PERMS,
<br />2.1 WATER ABSORPTION iN ACCORDANCE WITH ASTM C20S: LESS THAN 1 PERCENT BY
<br />VOLUME.
<br />2.8 DIMENSIONAL STABILITY IN ACCORDANCE WITH ASTM 02126: LESS THAN 2 PERCENT
<br />LINEAR CHANGE.
<br />2.9 AIR PERKEANCE IN ACCORDANCE WITH ASTM E2118: LESS THAN 0.02 L/(SM2)
<br />2.10 SERVICE TEMPERATURE: -40 DEGREE F TO +250 DEGREE F (-38 DEGREE C TO 121
<br />DEGREE C).
<br />2.11 THICKNESS: 05 INCHES (13MM).
<br />A THERMAL RESISTANCE (R): 32.
<br />2.12 THICKNESS: 0.15 INCHES (I°rIKM),
<br />A. THERMAL RESISTANCE (R). 5.0.
<br />2.13 THICKNESS: 1.0 INCHES (25MM).
<br />A. THERMAL RESISTANCE (R): 6.0.
<br />2.14 THICKNESS: 15 INCHES (38MM).
<br />A THERMAL RESISTANCE (R). 9.6.
<br />2.15 THICKNESS: 2.0 INCHES (51MM).
<br />A THERMAL RESISTANCE (RA 13.1.
<br />PRODUCT DATA SHEET 5 - DURASWEATH-3: CLOSED -CELL POLYISOCYANURATE
<br />INSULATION WITH AN INORGANIC POLYMER
<br />PRODUCT DATA SHEET 6 - WALL PANEL ACCESSORIES: PROVIDE COMPONENTS
<br />REQUIRED FOR A COMPLETE METAL WALL PANEL ASSEMBLY INCLUDING TRIM,
<br />COPINGS, FASCIAE, SPLINES, CORNER UNiTS, CLIPS, FLASHINGS, SEALANTS,
<br />GASKETS, FILLERS, CLOSURE STRIPS, AND SIMILAR ITEMS. MATCH MATERIAL
<br />AND FINISH OF METAL WALL PANELS, UNLESS OTHERWISE INDICATED.
<br />PRODUCT DATA SHEET 1 - FABRICATION: FABRICATE AND FINISH METAL WALL PANELS
<br />AND ACCESSORIES AT THE FACTORY TO GREATEST EXTENT POSSIBLE, BY
<br />MANUFACTURE'S STANDARD PROCEDURES AND PROCESSES, AS NECESSARY TO
<br />FULFILL INDICATED PERFORMANCE REQUIREMENTS DEMONSTRATED BY
<br />LABORATORY TESTING. COMPLY WITH INDICATED PROFILES AND WITH DIMENSIONAL AND
<br />STRUCTURAL REQUIREMENTS.
<br />2.1 FORK PANEL LINES, BREAKS AND ANGLES TO BE SHARP AND TRUE, WITH
<br />SURFACES FREE FROM WARP AND BUCKLE.
<br />22 FABRICATE METAL WALL PANELS IN A MANNER THAT WOULD WEEP ANY
<br />POSSIBLE CONDENSATION TO THE EXTERIOR
<br />23 PROVIDE PANEL PROFILE FOR FULL LENGTH OF PANEL.
<br />2.4 FABRICATE METAL WALL PANEL JOINTS iN A MANNER THAT WILL MINIMIZE NOISE
<br />FROM MOVEMENTS WITHIN PANEL ASSEMBLY.
<br />25 FABRICATE PANELS, AS REQUIRED TO COMPLY WITH DEFLECTION LIMITS, WITHOUT
<br />THE USE OF BACKSIDE PANEL STIFFENERS.
<br />2.6 FABRICATE PANELS WITH SHARPLY CUT EDGES, WiTH NO DISPLACEMENT OF FACE
<br />SHEETS OR EXTERNAL EXPOSURE OF CORE MATERIAL.
<br />2.1 DIMENSIONAL TOLERANCES -
<br />A, LENGTH: PLUS 0315 INCH (95 MM).
<br />B. WiDTH: PLUS 0.188 INCH (48 MM).
<br />C. THICKNESS: PLUS OR MINUS 01d08 INCH (02 MM).
<br />D. PANEL BOW: 0.8 PERCENT MAXIMUM OR PANEL LENGTH OR WIDTH.
<br />E. SQUARENESS: 02 INCH (5 MM) MAXIMUM.
<br />PART 3 - EXECUTION
<br />SCHEDULE 0 - EXAMINATION
<br />PRODUCT DATA SHEET 0 - DO NOT BEGIN INSTALLATION UNTIL SUBSTRATES HAVE
<br />BEEN PROPERLY PREPARED.
<br />PRODUCT DATA SHEET 1 - IF SUBSTRATE PREPARATION IS THE RESPONSIBILITY OF
<br />ANOTHER INSTALLER NOTIFY ARCHITECT OF UNSATISFACTORY PREPARATION
<br />BEFORE PROCEEDING.
<br />SCHEDULE 1 - PREPARATION
<br />PRODUCT DATA SHEET 0 - CLEAN SURFACES THOROUGHLY PRIOR TO
<br />INSTALLATION.
<br />PRODUCT DATA SHEET i - PREPARE SURFACES USING THE METHODS RECOMMENDED
<br />BY THE MANUFACTURER FOR ACHIEVING THE BEST RESULT FOR THE SUBSTRATE
<br />UNDER THE PROJECT CONDITIONS.
<br />SCHEDULE 2 - INSTALLATION, GENERAL
<br />PRODUCT DATA SHEET 0 - INSTALL IN ACCORDANCE WITH MAINUFACTURER'S
<br />INSTRUCTIONS AND iN PROPER RELATIONSHIP WITH ADJACENT CONSTRUCTION.
<br />SCHEDULE 3 - INSTALLATION, RAINSCREEN PANEL SYSTEM
<br />PRODUCT DATA SHEET 0 - GENERAL: INSTALL METAL WALL PANELS IN ORIENTATION,
<br />SIZES, AND LOCATIONS INDICATED ON APPROVED SHOP DRAWINGS. INSTALL
<br />PANELS PERPENDICULAR TO GIRTS AND SUBGIRTS, UNLESS OTHERWISE INDICATED.
<br />ANCHOR METAL WALL PANELS AND OTHER COMPONENTS OF THE WORK SECURELY
<br />IN PLACE, WITH PROVISIONS FOR THERMAL AND STRUCTURAL MOVEMENT.
<br />PRODUCT DATA SHEET I - INSTALL ATTACHMENT SYSTEM REQUIRED TO SUPPORT
<br />WALL PANELS AND TO PROVIDE A COMPLETE WEATHERTIGHT WALL SYSTEM,
<br />INCLUDING POLYISOCYANURATE SHEATHING, TAPES, FLASHING, SUBGIRTS,
<br />PERIMETER EXTRUSIONS, TRACKS, PANEL CLIPS, AND ANCHOR CHANNELS AS MAY
<br />BE REQUIRED. SEALANTS SHALL BE UTILIZED AT TYPICAL VERTICAL OR
<br />HORIZONTAL JOINTS, WHERE APPLICABLE. PANEL JOINTS SHALL INCLUDE A SPLINE
<br />FABRICATED FROM SAME ACM SYSTEM AS PANELS.
<br />PRODUCT DATA SHEET 2 - INSTALLATION TOLERANCES: SHIM AND ALIGN METAL
<br />WALL PANEL UNITS WITHIN INSTALLED TOLERANCE OF 1/4 INCH IN 20 FEET (6 MM
<br />IN 6 M), NON -ACCUMULATIVE, ON LEVEL, PLUMB, AND LOCATION LINES AS
<br />INDICATED AND WITHIN 1/8 INCH (3 MM) OFFSET OF ADJOINING FACES AND OF
<br />ALIGNMENT OF MATCHING PROFILES
<br />SCHEDULE 4 - PROTECTION
<br />PRODUCT DATA SHEET 0 - PROTECT INSTALLED PRODUCTS UNTIL COMPLETION OF
<br />PROJECT.
<br />PRODUCT DATA SHEET 1 - TOUCH-UP, REPAIR OR REPLACE DAMAGED PRODUCTS
<br />BEFORE SUBSTANTIAL COMPLETION.
<br />SECTION 012115
<br />BATT INSULATION
<br />PART GENERAL
<br />IJ SUMMARY
<br />ASECTiON INCLUDES:
<br />I. BATT INSULATION IN EXTERIOR WALL AND ROOF ASSEMBLIES.
<br />13 SUBMITTALS
<br />A -SUSTAINABLE DESIGN SUBMITTALS.
<br />I. RECYCLED CONTENT.
<br />2. REGIONAL MATERIALS.
<br />3. RAPIDLY RENEWABLE MATERIALS.
<br />4. RECYCLED CONTENT
<br />i)FOR PRODUCTS HAVING RECYCLED CONTENT, DOCUMENTATION INDICATING
<br />PERCENTAGES BY WEIGHT OF POSTCONSUMER AND PRE CONSUMER RECYCLED
<br />CONTENT. INCLUDE STATEMENT INDICATING COSTS FOR EACH PRODUCT HAVING
<br />RECYCLED CONTENT.
<br />IA PROJECT CONDITIONS
<br />ADO NOT INSTALL UNTIL INSULATION UNTIL BUILDING IS SUBSTANTIALLY WATER AND
<br />WEATHER TiGHT.
<br />PART 2 PRODUCTS
<br />2.1 MATERIALS
<br />ATHERMAL BATT INSULATION:
<br />I. TYPE: ASTM C665, GLASS Fi5ER COMPOSITION.
<br />2. FACING: REINFORCED KRAFT PAPER VAPOR BARRIER ON ONE SIDE WITH
<br />STAPLING FLANGES OR ALUMINUM FOIL/SCRiM)KRAFT PAPER VAPOR BARRIER ON
<br />ONE SIDE WITH STAPLING FLANGES.
<br />3. FREE FROM UREA -FORMALDEHYDE RESINS.
<br />()INSULATION MANUFACTURED WITH 100 PERCENT ACRYLIC BINDERS AND NO
<br />FORMALDEHYDE.
<br />4. THERMAL RESISTANCE:
<br />a. 3-i/2 INCHES THICK: R-VALUE OF 1100.
<br />b. 3-5/8 INCHES THICK R-VALUE OF 13.00.
<br />c. 6-1/4 INCHES THICK: R-VALUE OF ISOO.
<br />d. 6-1/2 INCHES THICK: R-VALUE OF 22.0.
<br />a. 8-1/2 INCHES THICK: R-VALUE OF 25.0.
<br />P. S INCHES THICK: R-VALUE OF 26.0.
<br />g. 10 INCHES THICK: R-VALUE OF 3000.
<br />h 12 INCHES THiCK: R-VALUE OF 38.00.
<br />3. TRIM AND ACCESSORIES.
<br />13 SYSTEM DESCRIPTION
<br />ASYSTEM CLASSIFICATION: EIMA CLASS PB, STANDARD AND HIGH IMPACT RESISTANCE.
<br />BFIRE HAZARD CLASSIFICATION: MAXIMUM FLAME SPREAD/SMOKE DEVELOPED RATING
<br />OF 25/450, TESTED TO ASTM E84.
<br />1.4 SUBMITTALS
<br />A.SUBMITTALS FOR REVIEW:
<br />1. SHOP DRAWINGS: INDICATE JOINT LAYOUT AND DIMENSIONS, SYSTEM PENETRATION
<br />DETAILS, AND TERMINATION DETAILS.
<br />2. PRODUCT DATA: INCLUDE PRIMARY AND SECONDARY PRODUCT DESCRIPTIONS,
<br />APPLICATION INSTRUCTIONS, PERFORMANCE CRITERIA, AND LIST OF SEALANTS
<br />APPROVED FOR USE WITH SYSTEM.
<br />3. SAMPLES:
<br />a. 3 X 3 INCH FINISH COAT SAMPLES FOR ALL APPLICABLE COLORS SHOWN ON
<br />DRAWINGS.
<br />4. WARRANTY: SAMPLE WARRANTY FORK.
<br />B.QUALITY CONTROL SUBMITTALS:
<br />1. CERTIFICATES OF COMPLIANCE:
<br />a. MANUFACTURER'S CERTIFICATION THAT INSTALLED SYSTEM COMPLIES WITH
<br />REQUIREMENTS OF CONTRACT DOCUMENTS.
<br />b. CERTIFICATE OF APPROVAL BY CODE AUTHORITIES HAVING JURISDICTION OVER
<br />PROJECT.
<br />c. CERTIFICATION FROM AN INDEPENDENT TESTING LABORATORY THAT SYSTEM
<br />MEETS FIRE HAZARD CLASSIFICATION RECUIiRREMENTS.
<br />15 QUALITY ASSURANCE
<br />AFURNiSH EIFS SYSTEM COMPONENTS FROM SINGLE MANUFACTURER
<br />BJNSTALLER QUALIFICATIONS: MINIMUM 5 YEARS DOCUMENTED EXPERIENCE IN WORK OF
<br />THIS SECTION.
<br />1.6 DELIVERY, STORAGE AND HANDLING
<br />ASTORE ADHESIVES AND COATINGS IN PROTECTED, DRY AREA UNTIL USED, AT
<br />TEMPERATURE PER THE MANUFACTURER'S PRODUCT SPECIFICATIONS.
<br />1.1 PROJECT CONDITIONS
<br />ADO NOT APPLY ADHESIVES AND COATINGS IF:
<br />1. AMBIENT TEMPERATURE IS BELOW 40 DEGREES F, OR IS EXPECTED TO FALL
<br />BELOW THAT TEMPERATURE WITHIN 24 HOURS AFTER APPLICATION.
<br />2. RELATIVE HUMIDITY iS ABOVE 85 PERCENT AND SURFACE TEMPERATURE IS LOWER
<br />THAN 5 DEGREES F BELOW DEW POINT.
<br />3. WIND VELOCITY IS OVER 20 MPH.
<br />lb WARRANTIES
<br />A.FURNISH MANUFACTURER'S AND APPLICATOR'S SEPARATE STANDARD WARRANTY
<br />PROVIDING COVERAGE AGAINST AIR AND WATER LEAKAGE THROUGH EIFS SYSTEM.
<br />PART 2 PRODUCTS
<br />2J MANUFACTURERS
<br />AACCEPTABLE MANUFACTURERS:
<br />1. DRYVIT SYSTEM, INC. (WWWDRYVIT:COM)
<br />B.SUBSTITUTIONS: ALLOWED UPON APPROVAL OF CLIENT OR DESIGN PROFESSIONAL.
<br />22 MATERIALS
<br />A.MOISTURE BARRIER: FLUID -APPLIED TYPEt SYSTEM MANUFACTURER'S STANDARD
<br />PRODUCT.
<br />BADHESIVE: ACRYLIC BASEDt TYPE RECOMMENDED BY SYSTEM MANUFACTURER
<br />CANISH COAT: EIMA CLASS PBt POLYMER BASE, MEDIUM TEXTURE, COLORS AS SHOWN
<br />ON DRAWINGS.
<br />D. RIGID INSULATION:
<br />I. ASTM C518, TYPE VI, CLOSED CELL EXTRUDED POLYSTYRENE, SLOTTED ON BACK
<br />SIDE FOR DRAINAGE.
<br />2. EDGES: SQUARE.
<br />3. MINIMUM THICKNESS: 2 INCHES.
<br />4. THERMAL RESISTANCE: MINIMUM R VALUE OF 10.
<br />E.REINFORCING: GLASS FIBER MESH, BALANCED OPEN WEAVE, ALKALINE RESISTANT,
<br />TREATED FOR IMPROVED BOND WiTH COATING, TESTED TO ASTM E2098 AND
<br />CLASSIFIED TO EIMA IMPACT CLASSIFICATION.
<br />1. STANDARD IMPACT MESH: MINIMUM 45 OUNCES PER SQUARE YARD.
<br />2. HIGH IMPACT MESH: MINIMUM 140 OUNCES PER SQUARE YARD.
<br />3. CORNER MESH: MINIMUM 20.0 OUNCES PER SQUARE YARD.
<br />23 ACCESSORIES
<br />A.TRIM:
<br />I. EXTRUDED PVC, PERFORATED ATTAC41ENT FLANGES, OF LONGEST PRACTICAL
<br />LENGTH.
<br />2. CORNER BEAD: BEADED EDGE, SIZE AND PROFILE TO SUIT APPLICATION.
<br />3. CASNG BEAD: THICKNESS GOVERNED BY SYSTEM THICKNESS, SQUARE EDGE.
<br />4. DRAINAGE CASING: THICKNESS GOVERNED BY SYSTEM THICKNESS, SQUARE EDGE,
<br />PERFORATED FOR DRAINAGE.
<br />5. CONTROL JOINT: ACCORDION PROFILE WITH MINIMUM 2 INCH FLANGES EACH SIDE,
<br />WITH ATTACHMENT FLANGES.
<br />BJNSULATION FASTENERS: HOT -DIP GALVANIZED OR FLUOROPOLYMER COATED STEEL
<br />WITH MINIMUM 1 INCH DIAMETER WASHERS, MINIMUM 5/8 INCH PENETRATION INTO
<br />FRAMING, OF TYPE RECOMMENDED BY SYSTEM MANUFACTURER
<br />C.TRiM FASTENERS: HOT -DIP GALVANIZED OR FLUOROPOLYMER COATED STEEL, TYPE
<br />RECOMMENDED BY SYSTEM MANUFACTURER
<br />D. WATER CLEAN AND POTABLE.
<br />2A MIXES
<br />ABASE AND FINISH COAT: IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
<br />PART 3 EXECUTION
<br />3.1 APPLICATION OF MOISTURE BARRIER
<br />A.APPLY MOISTURE BARRIER IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
<br />B-APPLY MOISTURE BARRIER BY ROLLER TO CONTINUOUS AND UNIFORM COVERAGE
<br />WITH MINIMUM MIL THICKNESS AS RECOMMENDED BY MANUFACTURER
<br />C.0 X'IPLETELY JOINT COMPOUND APPLIED AT CRACKS, JOINTS, PERIMETER AND
<br />PENETRATIONS WITH MOISTURE BARRIER
<br />D. INSTALL HEAVY MESH UP TO 8 FEET ABOVE GRADE OR PAVING.
<br />E.INSTALL CORNER MESH FOR MINIMUM 12 INCHES ON BOTH SIDES OF EXTERNAL
<br />CORNERS.
<br />F. INSTALL DRAINAGE CASING AT WALL BASE AND OVER OPENINGS IN WALLS. SEAL
<br />CORNERS AND INTERSECTIONS.
<br />32 APPLICATION OF INSULATION AND REINFORCING
<br />AINSTALL SYSTEM IN ACCORDANCE WITH ANSI/EIMA SSA AND MANUFACTURER'S
<br />INSTRUCTIONS.
<br />B.ADHERE INSULATION TO SUBSTRATE WITH FULL ADHESIVE BED APPLIED USING
<br />NOTCHED TROWEL, WITH DRAINAGE CHANNELS RUNNING VERTICALLY.
<br />i. INSTALL INSULATION IN MOST ECONOMICAL MANNER, WITH JOINTS OFFSET JOINTS
<br />FROM THOSE IN SUBSTRATE.
<br />2. STAGGER END JOINTS IN ADJACENT ROWS MINIMUM 12 INCHES.
<br />3. CUT PANELS TO FIT AT PERIMETER AND AROUND PENETRATIONS.
<br />4. PRESS TO FULL CONTACT WITH ADHESIVE WITHOUT RESTRICTING DRAINAGE BEHIND
<br />PANELS.
<br />C.APPLY MINIMUM 1/16 INCH LAYER OF ADHESIVE OVER INSULATION BOARD.
<br />D. FULLY EMBED REINFORCEMENT IN ADHESIVE, WRINKLE FREE.
<br />E.LAP ENDS AND EDGES 2 INCHES MINIMUM.
<br />F. WRAP REINFORCEMENT AND ADHESIVE AROUND INSULATION EDGE AT REVEALS,
<br />CONTROL JOINTS AND WHERE SYSTEM ABUTS DISSIMILAR MATERIALS OR STOPS WITH
<br />EDGE EXPOSED EXCEPT AT BOTTOM EDGES.
<br />33APPLICATION OF FINISH COAT
<br />A.APPLY IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.
<br />B.WORK IN CONTINUOUS OPERATION IN EACH PANEL FORMED BY TRIM AND
<br />INTERSECTIONS TO ENSURE EVEN TEXTURE.
<br />C.CUT EDGES IN CLEAN AND SHARP WHERE WORK JOINS OTHER MATERIALS.
<br />D. APPLY TO UNIFORM TEXTURE AND COLOR WITHOUT STREAKS, LAPS, HEAVY BUILDUPS,
<br />AND MISSED ALAS.
<br />E.ENSURE CONSISTENT APPLICATION AND UNIFORM APPEARANCE.
<br />3A ADJUSTING
<br />TOUCH UP FINISH COAT AS REQUIRED TO OBTAIN UNIFORM TEXTURE.
<br />PART i - GENERAL
<br />SECTION 012500
<br />WEATHER BARRIERS
<br />DUPONT TM TYVEK8 THERMAWRAP TM
<br />PART 3 EXECUTION 1.1 SECTION INCLUDES
<br />3.1 INSTALLATION A.WEATHER BARRIER MEMBRANE (DUPONTTm TYVEKO THERMAWRAPTM)
<br />ASTAPLE OR NAIL IN PLACE AT MAXIMUM 12 INCHES ON CENTER
<br />B.BUTT INSULATION TO ADJACENT CONSTRUCTION. BUTT ENDS AND EDGES. B.SEAM TAPE (DUPONTTM TYVEKS METALLIZED CAPE OR DUPONTTM TYVEK® TAPE)
<br />C.CARRY INSULATION AROUND PIPES, WIRING, BOXES, AND OTHER COMPONENTS. C.FLASHING (DUPONTTM FLEXWRAPTM DUPONTTM FLEXWRAPT"NF, DUPONTTm
<br />D. ENSURE COMPLETE ENCLOSURE OF SPACES WITHOUT VOIDS. STRAIGHTFLASHTM, DUPONTTM STRAIGHTFLASHTM VF, AND/OR DUPONTTm THRU-WALL
<br />E.APPLY WITH VAPOR BARRIER FACING TOWARDS EXTERIOR OR INTERIOR OF FLASHING)
<br />STRUCTURE BASED ON LOCAL CLIMATE DESIGN REQUIREMENTS. D. FASTENERS
<br />F. TAPE SEAL LAPPED FLANGES, BUTT ENDS, AND TEARS AND HOLES IN FACINGS.
<br />SECTION 012400
<br />EXTERIOR INSULATION AND FINISH SYSTEM
<br />PART GENERAL
<br />I.i SUMMARY
<br />ASECTiON INCLUDES:
<br />1. MOISTURE BARRIER
<br />2. COMPOSITE WALL CLADDING OF RIGID INSULATION AND APPLIED COATING.
<br />1.2 SUBMITTALS
<br />ARM R TO SECTION 3/401 33 00 SUBMITTAL PROCEDURES4 1/4INSERT SECTION NUMBER
<br />AND TITLE16.
<br />B.PRODUCT DATA: SUBMIT MANUFACTURER CURRENT TECHNICAL LITERATURE FOR EACH
<br />COMPONENT.
<br />C.SAMPLES. WEATHER BARRIER MEMBRANE, MINIMUM 8-1/2 INCHES BY Il INCH.
<br />D. QUALITY ASSURANCE SUBMITTALS
<br />1. DESIGN DATA, TEST REPORTS: PROVIDE MANUFACTURER TEST REPORTS
<br />INDICATING PRODUCT COMPLIANCE WITH INDICATED REQUIREMENTS.
<br />2. MANUFACTURER INSTRUCTIONS: PROVIDE MANUFACTURER'S WRITTEN INSTALLATION
<br />INSTRUCTIONS.
<br />3. MANUFACTURER'S FIELD SERVICE REPORTS: PROVIDE SITE REPORTS FROM
<br />AUTHORIZED FIELD SERVICE REPRESENTATIVE, INDICATING OBSERVATION OF
<br />WEATHER BARRIER ASSEMBLY INSTALLATION.
<br />E.CLOSEOUT SUBMITTALS
<br />1. REFER TO SECTION 3/401 18 00 CLOSEOUT SUBMITTALS'ib -4/41NSERT SECTION NUMBER
<br />AND TITLEZ6.
<br />2. WEATHER BARRIER MANUFACTURER'S WARRANTY: MANUFACTURER'S EXECUTED
<br />WARRANTY FORM WITH AUTHORIZED SIGNATURES AND ENDORSEMENTS INDICATING
<br />DATE OF UJEAT14ER BARRIER PURCHASE.
<br />13 QUALITY ASSURANCE
<br />AQUALUFiCATIONS
<br />I. INSTALLER SHALL HAVE EXPERIENCE WITH INSTALLATION OF DUPONT TM TYVEK®
<br />WEATHER BARRIER ASSEMBLIES UNDER SIMILAR CONDITIONS.
<br />2. INSTALLATION SHALL BE IN ACCORDANCE WiTH WEATHER BARRIER
<br />MANUFACTURER'S INSTALLATION GUIDELINES AND RECOMMENDATIONS.
<br />3. SOURCE LIMITATIONS: PROVIDE WEATHER BARRIER AND ACCESSORY MATERIALS
<br />PRODUCED BY SINGLE MANUFACTURER
<br />BMOCK-UP
<br />1. INSTALL MOCK-UP USING APPROVED WEATHER BARRIER ASSEMBLY INCLUDING
<br />FASTENERS, FLASHING, TAPE AND RELATED ACCESSORIES PER MANUFACTURER'S
<br />CURRENT PRINTED INSTRUCTIONS AND RECOMMENDATIONS.
<br />a. MOCK-UP SIZE: 3/410 FEET BY 10 FEET16 3/41NSERT SIZE7b.
<br />b. MOCK-UP SUBSTRATE: MATCH WALL ASSEMBLY CONSTRUCTION, INCLUDING
<br />WINDOW OPENING.
<br />2. CONTACT MANUFACTURER'S DESIGNATED REPRESENTATIVE PRIOR TO WEATHER
<br />BARRIER ASSEMBLY INSTALLATION, TO PERFORM REQUIRED MOCK-UP VISUAL
<br />INSPECTION AND ANALYSIS AS REQUIRED FOR WARRANTY.
<br />C.PRE-INSTALLATION MEETING
<br />I. REFER TO SECTION 3/401 31 IS PROJECT MEETINGStib 3/41NSERT SECTION NUMBER AND
<br />TITLE16.
<br />2. HOLD A PRE -INSTALLATION CONFERENCE, TWO WEEKS PRIOR TO START OF
<br />WEATHER BARRIER INSTALLATION. ATTENDEES SHALL INCLUDE CONTRACTOR,
<br />ARCHITECT, INSTALLER OWNER'S REPRESENTATIVE, AND WEATHER BARRIER
<br />MANUFACTURER'S DESIGNATED REPRESENTATIVE.
<br />3. REVIEW ALL RELATED PROJECT REQUIREMENTS AND SUBMITTALS, STATUS OF
<br />SUBSTRATE WORK AND PREPARATION, AREAS OF POTENTIAL CONFLICT AND
<br />INTERFACE, AVAILABILITY OF WEATHER BARRIER ASSEMBLY MATERIALS AND
<br />COMPONENTS, INSTALLER'S TRAINING REQUIREMENTS, EQUIPMENT, FACILITIES AND
<br />SCAFFOLDING, AND COORDINATE METHODS, PROCEDURES AND SEQUENCING
<br />REQUIREMENTS FOR FULL AND PROPER INSTALLATION, INTEGRATION AND
<br />PROTECTION.
<br />1.4 DELIVERY, STORAGE AND HANDLING
<br />AREFER TO SECTION 3/401 60 00 PRODUCT REMIREMENTS16 3441NSERT SECTION
<br />NUMBER AND TITLET6.
<br />B.DELIVER WEATHER BARRIER MATERIALS AND COMPONENTS IN MANUFACTURER'S
<br />ORIGNAL, UNOPENED, UNDAMAGED CONTAINERS WITH IDENTIFICATION LABELS INTACT
<br />C.STORE WEATHER BARRIER MATERIALS AS RECOMMENDED BY WEATHER BARRIER
<br />MANUFACTURER
<br />1.5 SCHEDULING
<br />A.REVIEW REQUIREMENTS FOR SEQUENCING OF INSTALLATION OF WEATHER BARRIER
<br />ASSEMBLY WITH INSTALLATION OF WINDOWS, DOORS, LOUVERS AND FLASHINGS TO
<br />PROVIDE A WEATHER -TIGHT BARRIER ASSEMBLY.
<br />B.SCHEDULE INSTALLATION OF WEATHER BARRIER MATERIALS AND EXTERIOR
<br />CLADDING WITHIN FOUR MONTHS OF WEATHER BARRIER ASSEMBLY INSTALLATION.
<br />Ib WARRANTY
<br />AREFER TO SECTION 3/401 18 36 WARRANTIESZb 3/4INSERT SECTION NUMBER AND TITLE'tb.
<br />B.SPECIAL MANUFACTURER'S WARRANTY
<br />I. WEATHER BARRIER MANUFACTURER'S WARRANTY FOR WEATHER BARRIER FOR A
<br />PERIOD OF TEN YEARS FROM DATE OF WEATHER BARRIER PURCHASE.
<br />2. PRE -INSTALLATION MEETINGS AND J05SITE OBSERVATIONS BY WEATHER BARRIER
<br />MANUFACTURER FOR WARRANTY ARE REQUIRED PRIOR TO ASSEMBLY
<br />INSTALLATION.
<br />3. MANUFACTURER'S WARRANTY AREAS: 3/40ESCRIBE SPECIFIC AREAS OF WORK
<br />PROTECTED AND AREAS OF WORK EXCLUDED AS REQUIRED BY PROJECT
<br />CONDITIONS%.
<br />4. FOR WARRANTY DETAILS REVIEW MANUFACTURER'S PUBLISHED WARRANTY. THE
<br />FOREGOING IS MERELY A BRIEF SUMMARY OF THE WARRANTY AND
<br />MANUFACTURER'S OBLIGATIONS ARE LIMITED TO THOSE SET OUT IN THE WARRANTY
<br />DOCUMENT.
<br />PART 2 - PRODUCTS
<br />2.1 MANUFACTURER
<br />ADUPONTt 4411 LANCASTER PIKE, CHESTNUT RUN PLAZA 128, WILMINGTON, DE 19805t
<br />I-SW-44-TYVEK (8-W35)t HTTP://UWUWZONSTRUCTION.TYVEK.COM
<br />22 MATERIALS
<br />ABASIS OF DESIGN: SPUNBONDED POLYOLEFIN, NON -WOVEN, NON -PERFORATED,
<br />WEATHER BARRIER IS BASED UPON DUPONTTM TYVEKS THERMAW@APTm AND RELATED
<br />ASSEMBLY COMPONENTS.
<br />B.PERFORIMANCE CHARACTERISTICS (VALUES LISTED ARE NOMINAL VALUES MEASURED
<br />BY AN ACCREDITED THIRD PARTY LAB-).
<br />1. EFFECTIVE R-VALUE: R-2 (INCLUDING %" MINIMUM AIRSPACE), AS DESIGNATED ON
<br />ASHRAE TABLES, ASTM HANDBOOK OF FUNDAMENTALS, CHAPTER 25- TABLE 3.
<br />2. AiR PENETRATION: 0002 CFM+M AT 151 PSF, WHEN TESTED IN ACCORDANCE WITH
<br />ASTM E 2118.
<br />3. WATER VAPOR TRANSMISSION: 68 PERMS, WHEN TESTED IN ACCORDANCE WITH
<br />ASTM
<br />E S6, METHOD 5.
<br />4. WATER PENETRATION RESISTANCE: 210 CM WHEN TESTED IN ACCORDANCE WITH
<br />AATCC TEST METHOD 121.
<br />5. BASIS WEIGHT: 25 OZ/YD2, WHEN TESTED IN ACCORDANCE WITH TAPPI TEST
<br />METHOD T-410.
<br />6. AiR RESISTANCE: AIR INFILTRATION AT 1EI000 SECONDS, WHEN TESTED IN
<br />ACCORDANCE WITH TAPPI TEST METHOD T-460.
<br />1. TENSILE STRENGTH: 29/21 1-55AN, WHEN TESTED IN ACCORDANCE WITH ASTM D 882,
<br />METHOD A.
<br />S. TEAR RESISTANCE: 12/1 LBS., WHEN TESTED IN ACCORDANCE WITH ASTM D 1111.
<br />S. SURFACE BURNING CHARACTERISTICS: CLASS A, WHEN TESTED IN ACCORDANCE
<br />WITH ASTM E 84. FLAME SPREAD: 10, SMOKE DEVELOPED: 40.
<br />23 ACCESSORIES
<br />SEAM TAPE. DUPONTT" TYVEK® METALLIZED TAPE OR DUPONTT" TYVEKS TAPE AS
<br />DISTRIBUTED BY DUPONT.
<br />AFASTENERS:
<br />1. TYVEK® WRAP CAP SCREWS, AS DISTRIBUTED BY DUPONT: 1-5/8 INCH RUST
<br />RESISTANT SCREW WITH 2-INC44 DIAMETER PLASTIC CAP FASTENERS.
<br />AND/OR
<br />2. TYVEKV WRAP CAPS, AS DISTRIBUTED BY DUPONT: 04 NAILS WITH LARGE 1-INC4
<br />PLASTIC CAP FASTENERS OR 1-INC44 CAP STAPLES.
<br />AND/OR
<br />3. MASONRY TAP -CON FASTENERS WITH TYVEKV WRAP CAPS AS DISTRIBUTED BY
<br />DUPONT. 2-INCH DIAMETER PLASTIC CAP FASTENERS.
<br />B.SEALANTS
<br />I. REFER TO SECTION 3/401 S2 00 JOINT SEALANTSi6 3/41NSERT SECTION NUMBER AND
<br />TITLE16.
<br />OR
<br />2. PROVIDE SEALANTS THAT COMPLY WITH ASTM C S20, ELASTOMERIC POLYMER
<br />SEALANT TO MAINTAIN WATERTIGHT CONDITIONS.
<br />3. PRODUCTS:
<br />a. DUPONTTO RESIDENTIAL SEALANT
<br />Iv. DUPONTT" COMMERCIAL SEALANT
<br />c. SEALANTS RECOMMENDED BY THE WEATHER BARRIER MANUFACTURER
<br />CADHESI VES:
<br />I. PROVIDE ADHESIVE RECOMMENDED BY WEATHER BARRIER MANUFACTURER
<br />2. PRODUCTS:
<br />a. LIQUID NAILS® LN-10S
<br />b. DENSO BUTYL LIQUID
<br />c. 3M HIGH STRENGTH 80
<br />d. SIA 655
<br />a. ADHESIVES RECOMMEND BY THE WEATHER BARRIER MANUFACTURER
<br />D. PRIMERS:
<br />I. PROVIDE FLASHING MANUFACTURER RECOMMENDED PRIMER TO ASSIST IN
<br />ADHESION BETWEEN SUBSTRATE AND FLASHING.
<br />2. PRODUCTS:
<br />a. 3M HiGH STRENGTH W
<br />b. DENSO BUTYL SPRAY
<br />c. SIA 655
<br />d. PERMAGRIP 105
<br />a. PRIMERS RECOMMENDED BY THE FLASHING MANUFACTURER
<br />E.FLASHING
<br />I. DUPONT- FLEXWRAP-, AS DISTRIBUTED BY DUPONT. FLEXIBLE MEMBRANE
<br />FLASHING MATERIALS FOR WINDOW OPENINGS AND PENETRATIONS.
<br />AND/OR
<br />2. DUPONTTM FLEXWRAPTm NF, AS DISTRIBUTED BY DUPONT: FLEXIBLE MEMBRANE
<br />FLASHING MATERIALS FOR WiNDOW OPENINGS AND PENETRATIONS.
<br />AND/OR
<br />3. DUPONT- STRAIGHTFLASHTM, AS DISTRIBUTED BY DUPONT: STRAIGHT FLASHING
<br />MEMBRANE MATERIALS FOR FLASHING WINDOWS AND DOORS AND SEALING
<br />PENETRATIONS SUCH AS MASONRY TIES, ETC.
<br />AND/OR
<br />4. DUPONTTM STRAIGHTFLASHTM VF, AS DISTRIBUTED BY DUPONT: DUAL -SIDED
<br />STRAIGHT FLASHING MEMBRANE MATERIALS FOR BRICK MOLD AND NON -FLANGED
<br />WINDOWS AND DOORS.
<br />AND/OR
<br />5. DUPONTTm THRU-WALL SURFACE ADHERED MEMBRANE WITH INTEGRATED DRIP
<br />EDGE. THRU-WALL FLASHING MEMBRANE MATERIALS FOR FLASHING AT CHANGES IN
<br />DIRECTION OR ELEVATION (SHELF ANGLES, FOUNDATIONS, ETC.) AND AT
<br />TRANSITIONS BETWEEN DIFFERENT ASSEMBLY MATERIALS.
<br />AND/OR
<br />6. PFREFORMED INSIDE AND OUTSIDE CORNERS AND END DAMS AS DISTRIBUTED BY
<br />DUPONT; PREFORMED THREE-DIMENSIONAL SHAPES TO COMPLETE THE FLASHING
<br />SYSTEM USED IN CONJUNCTION WITH DUPONTTM THRU-WALL FLASHING.
<br />PART 3 - EXECUTION
<br />3.1 EXAMINATION
<br />AVERIFY SUBSTRATE AND SURFACE CONDITIONS ARE IN ACCORDANCE WITH WEATHER
<br />BARRIER MANUFACTURER RECOMMENDED TOLERANCES PRIOR TO INSTALLATION OF
<br />WEATHER BARRIER AND ACCESSORIES.
<br />32 INSTALLATION - WEATHER BARRIER
<br />AINSTALL WEATHER BARRIER OVER EXTERIOR FACE OF EXTERIOR WALL SUBSTRATE IN
<br />ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS
<br />BJNSTALL WEATHER BARRIER PRiOR TO INSTALLATION OF WINDOWS AND DOORS.
<br />C.START WEATHER BARRIER INSTALLATION AT A BUILDING CORNER LEAVING 6-12
<br />INCHES OF WEATHER BARRIER EXTENDED BEYOND CORNER TO OVERLAP.
<br />D. INSTALL WEATHER BARRIER SILVER SIDE FACING AIR SPACE.
<br />E.INSTALL WEATHER BARRIER IN A HORIZONTAL MANNER STARTING AT THE LOWER
<br />PORTION OF T14E WALL SURFACE WITH SUBSEQUENT LAYERS INSTALLED N A
<br />SHINGLING MANNER TO OVERLAP LOWER LAYERS. MAINTAIN WEATHER BARRIER
<br />PLUMB AND LEVEL
<br />F. SILL PLATE INTERFACE: EXTEND LOWER EDGE OF WEATHER BARRIER OVER SILL
<br />PLATE INTERFACE
<br />3-6 INCHES. SECURE TO FOUNDATION WITH ELASTOMERIC SEALANT AS
<br />RECOMMENDED BY WEATHER BARRIER MANUFACTURER
<br />G.WINDOW AND DOOR OPENINGS: EXTEND WEATHER BARRIER COMPLETELY OVER
<br />OPENINGS.
<br />H.OVERLAP WEATHER BARRIER
<br />1. EXTERIOR CORNERS: MINIMUM 12 NCHES.
<br />2. SEAMS: MINIMUM 6 INCHES.
<br />I. WEATHER BARRIER ATTAC-41ENT:
<br />I. ATTACH WEATHER BARRIER TO STUDS THROUGH EXTERIOR SHEATHING. SECURE
<br />USING WEATHER BARRIER MANUFACTURER RECOMMEND FASTENERS, SPACE 6 -18
<br />INCHES VERTICALLY ON CENTER ALONG STUD LINE, AND 24 INCH ON CENTER
<br />MAXIMUM HORIZONTALLY.
<br />AND/OR
<br />2. ATTACH WEATHER BARRIER TO MASONRY. SECURE USING WEATHER BARRIER
<br />MANUFACTURER RECOMMEND FASTENERS, SPACE 6-I8 INCHES VERTICALLY ON
<br />CENTER AND 24 INCHES MAXIMUM HORIZONTALLY. WEATHER BARRIER MAY BE
<br />TEMPORARILY ATTACHED TO MASONRY USING RECOMMENDED ADHESIVE, PLACED
<br />N VERTICAL STRIPS SPACED 24 INCHES ON CENTER WHEN COORDINATED ON THE
<br />PROJECT SiTE.
<br />J. APPLY 4 NCH BY 1 INCH PIECE OF DUPONT TM STRAiGHTFLASHTM OR WEATHER
<br />BARRIER MANUFACTURER APPROVED ALTERNATE TO WEATHER BARRIER MEMBRANE
<br />PRIOR TO THE INSTALLATION CLADDING ANCHORS.
<br />33 SEAMING
<br />A.SEAL SEAMS OF WEATHER BARRIER WITH SEAM TAPE AT ALL VERTICAL AND
<br />HORIZONTAL OVERLAPPING SEAMS.
<br />5-SEAL ANY TEARS OR CUTS AS RECOMMENDED BY WEATHER BARRIER
<br />MANUFACTURER
<br />3.4 OPENING PREPARATION
<br />ACUT WEAT14ER BARRIER IN AN "-CUT" PATTERN. A MODIFIED "-CUT" IS ALSO
<br />ACCEPTABLE.
<br />I. CUT WEATHER BARRIER HORIZONTALLY ALONG THE BOTTOM AND TOP OF WINDOW
<br />OPENING.
<br />2. FROM TOP CENTER OF THE WINDOW OPENING, CUT WEATHER BARRIER VERTICALLY
<br />DOWN TO SILL.
<br />3. FOLD SIDE AND BOTTOM WEATHER BARRIER FLAPS INTO WINDOW OPENING AND
<br />FASTEN.
<br />B.CUT A HEAD FLAP AT 45-DEGREE ANGLE IN THE WEATHER BARRIER AT WINDOW HEAD
<br />TO EXPOSE 8 INCHES OF SHEATHING. TEMPORARILY SECURE WEATHER BARRIER
<br />FLAP AWAY FROM SHEATHING WITH TAPE.
<br />35 FLASHING
<br />ACUT 3/41-INC4'16 3/49-INCHli WIDE DUPONT- FLEXWRAPTMTE OR OUPONT- FLEXWRAPTM
<br />NF A MINIMUM OF 12 INCHES LONGER THAN WIDTH OF SILL ROUGH OPENING.
<br />B.COVER HORIZONTAL SILL BY ALIGNING DUPONTTM FLEXWRAPTM OR DUPONTTM
<br />FLEXWRAPTm NF EDGE WITH INSIDE EDGE OF SILL. ADHERE TO ROUGH OPENING
<br />ACROSS SILL AND UP JAMBS A MINIMUM OF 6 INCHES. SECURE FLASHING TIGHTLY
<br />INTO CORNERS BY WORKING IN ALONG THE SILL BEFORE ADHERING UP THE JAMBS.
<br />C.FAN DUPONTTM FLEXWRAPTm OR DUPONTTM FLEXWRAPTm NF AT BOTTOM CORNERS ONTO
<br />FACE OF WALL. FIRMLY PRESS IN PLACE. MECHANICALLY FASTEN FANNED EDGES.
<br />MECHANICAL FASTENING OF DUPONTTM FLEXWRAPTM NF IS NOT REQUIRED.
<br />D. ON EXTERIOR, APPLY CONTINUOUS BEAD OF SEALANT TO WALL OR BACKSIDE OF
<br />WINDOW MOUNTING FLANGE ACROSS JAMBS AND HEAD. DO NOT APPLY SEALANT
<br />ACROSS SILL.
<br />E.INSTALL WINDOW ACCORDING TO MANUFACTURER'S INSTRUCTIONS.
<br />F. APPLY 4-INC44 WIDE STRIPS OF DUPONT' STRAiGHTFLASHTM AT JAMBS OVERLAPPING
<br />ENTIRE MOUNTING FLANGE. EXTEND JAMB FLASHING 1-NC44 ABOVE TOP OF ROUGH
<br />OPENING AND BELOW BOTTOM EDGE OF SILL FLASHING.
<br />&APPLY 4-INCH WIDE STRIP OF DUPONTTM STRAIGHTFLASHTM AS HEAD FLASHING
<br />OVERLAPPING THE MOUNTING FLANGE. HEAD FLASHING SHOULD EXTEND BEYOND
<br />OUTSIDE EDGES OF BOTH JAMB FLASHINGS.
<br />H.POSITION WEATHER BARRIER HEAD FLAP ACROSS HEAD FLASHING. ADHERE USING
<br />4-INCH WIDE DUPONTTm STRAIGHTFLASHTm OVER THE 45-DEGREE SEAMS.
<br />I. TAPE HEAD FLAP IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS
<br />J. ON INTERIOR, INSTALL BACKER ROD IN JOINT BETWEEN FRAME OF WINDOW AND
<br />FLASHED ROUGH FRAMING. APPLY SEALANT AROUND ENTIRE WINDOW TO CREATE
<br />AiR SEAL. APPLY SEALANT IN ACCORDANCE WITH SEALANT MANUFACTURER'S
<br />INSTRUCTIONS AND ASTM C 1193.
<br />3.6 FIELD QUALITY CONTROL
<br />ANOTIFY MANUFACTURER'S DESIGNATED REPRESENTATIVE TO OBTAIN 34REQUIRED'16
<br />PERIODIC OBSERVATIONS OF WEATHER BARRIER ASSEMBLY INSTALLATION.
<br />3.1 PROTECTION
<br />APROTECT INSTALLED WEATHER BARRIER FROM DAMAGE.
<br />
|