KEYED NOTES: 0 <br />®EXISTING GREASE INTERCEPTOR IS INTENDED TO REMAIN FOR <br />REUSE. SIPHON OUT ALL LEFTOVER WASTE AND INSPECT <br />INTERCEPTOR FOR FAULTS AND CRACKS TO BE SURE THAT IT IS <br />IN GOOD OPERATING CONDITION. CLEAN TO PROVIDE A "LIKE <br />NEW" CONDITION. IF GREASE INTERCEPTOR CANNOT BE REUSED, <br />NOTIFY THE ARCHITECT AND ENGINEER IMMEDIATELY. <br />® REMOVE EXISTING WATER FILTER AND ALL EXISTING FW LINES. <br />® ALL FW CONNECTIONS ARE ROUTED TO A RECESSED WATER OUTLET <br />BOX MOUNTED AT I'-fo1i2" AFF, TO CENTER OF BOX U.N.O. RECESSED <br />WATER OUTLET BOX TO BE OX BOX MODEL %%-G2001WR <br />®PROVIDE (2) TWO 3i4"FW CONNECTIONS FOR EXISTING <br />OVENS. <br />® PROVIDE 3/4"FW CONNECTION FOR EXISTING ICE MACHINE. <br />®CONNECT NEW GREASE WASTE PIPING TO EXISTING GREASE WASTE <br />PIPE IN THI5 VICINITY, VERIFY SIZE, LOCATION AND INVERT PRIOR TO <br />START OF INSTALLING NEW SANITARY PIPE. <br />®EXTEND AND CONNECT TO EXISTING HW AND/OR CW <br />PIPING IN THIS VICINITY. FIELD COORDINATE LOCATIONS <br />PRIOR TO START OF WORK <br />® HAND SPRAYER FOR COFFEE STATION SHALL BE CONNECTED TO <br />THE 1/2 "FW FOR THE COFFEE STATION. <br />2 <br />OPROVIDE A PRESSURE REDUCING VALVE AT PLUMBING <br />CONNECTION TO ESPRESSO MACHINES. <br />�® EXTEND AND CONNECT TO EXISTING SANITARY SEWER <br />PIPE IN THIS VICINITY. FIELD COORDINATE INVERT WILL <br />ACCOMMODATE NEW PIPING. ADJUST AS NEEDED. <br />MAIN WATER FILTRATION SYSTEM BY OWNER WATER TESTING IS <br />REQUIRED PRIOR TO SELECTION OF WATER FILTRATION SYSTEM. <br />PROVIDE NEW SYSTEM PER TEST RESULTS AS FOLLOWS: <br />MECHANICAL FILTER SYSTEM FOR UNDER 200 TDS. STANDARD RO <br />FOR BETWEEN 200 4 300 TDS. COORDINATE WITH OWNER <br />ESPRESSO POINT OF USE SOFTENING CARTRIDGE FILTERS. <br />3/S"FW FROM FILTERS TO EACH ESPRESSO MACHINE. <br />ESPRESSO MACHINES MUST BE SERVED FROM SEPARATE <br />FW CARTRIDGES. ALL OTHER OX BOX CONNECTIONS ARE <br />SERVED FROM MAIN WATER FILTRATION SYSTEM. <br />�3 EXISTING MOP SINK PATCH, REPAIR, OR REPLACE AS <br />REQUIRED. G.G. TO VERIFY WITH OWNER <br />14 EXISTING TO REMAIN. <br />NOTE: <br />LOCATIONS SHOWN FOR WASTE PIPING ARE <br />SCHEMATIC IN NATURE. COORDINATE EXACT <br />CONNECTIONS REQUIRED WITH NEW EQUIPMENT <br />SPECIFICATIONS AND DUNKIN DONUTS CRITERIA. <br />4 <br />................................................................. { <br />OIIOLUM51NG SANITARY ,AND WATER i ENO FLAN <br />*'ALE: 3/16" ® 1'-0" <br />FLUM51NG GENERAL NOTES <br />1. ALL WORK SHALL COMPLY WITH ALL APPLICABLE <br />LOCAL AND STATE CODES AND AUTHORITIES HAVING <br />JURISDICTION. <br />2. PLUMBING CONTRACTOR SHALL SECURE AND PAY <br />FOR ALL REQUIRED PERMITS AND ARRANGE ALL <br />REQUIRED INSPECTIONS. <br />3. ALL CONTRACTORS SHALL EXAMINE THE SITE AND <br />REVIEW THE DRAWINGS AND SPECIFICATIONS PRIOR <br />TO SUBMITTING A PROPOSAL. <br />4. CONTRACTOR SHALL VERIFY DEPTH, SIZE, LOCATION <br />OF ALL EXISTING UTILITIES IN FIELD PRIOR TO <br />STARTING WORK <br />5. PLUMBING CONTRACTOR SHALL COORDINATE HIS / <br />HER WORK WITH OTHER CONTRACTORS IN <br />ESTABLISHING PIPE RUNS AND SPACE CONDITIONS. <br />b. ALL PIPING TO BE CONCEALED IN HUNG CEILINGS, <br />CHASES AND FURRED SPACES OR BELOW COUNTERS. <br />-1. THE DRAWINGS AS PREPARED ARE DIAGRAMMATIC <br />BUT SHALL BE FOLLOWED AS CLOSELY AS <br />CONSTRUCTION OF THE PROJECT AND THE WORK OF <br />THE TRADES WILL PERMIT. EQUIPMENT LOCATIONS <br />INDICATED ARE APPROXIMATE. COORDINATE EXACT <br />LOCATIONS AND REQUIRED CLEARANCES WITH <br />EQUIPMENT SUPPLIER AND ALL TRADES PRIOR TO <br />INSTALLATION. <br />8. REFER TO EQUIPMENT SCHEDULE AND EQUIPMENT <br />SPECIFICATIONS FOR EXACT LOCATIONS OF PLUMBING <br />CONNECTIONS, <br />S. WASTE AND VENT PIPING SHALL BE SCHEDULE 40 <br />P.Y.G. WITH DRAINAGE PATTERN FITTINGS. <br />10. ALL WATER PIPING SHALL BE TYPE "L" COPPER WITH <br />SOLDERED JOINTS. CPVC PIPING MAY BE USED IF <br />ACCEPTED BY JURISDICTION AND IF NO PLENUMS <br />EXIST. PROVIDE WATER HAMMER ARRESTORS EQUAL <br />TO JAY R. SMITH AT EACH FIXTURE GROUP. <br />11. SLOPE WASTE LINES 3" AND OVER, 1/8" PER FOOT. <br />LINES SMALLER THAN 3" SHALL SLOPED AT 1/4" PER <br />FOOT. <br />12. INSULATE ALL DOMESTIC HOT WATER PIPING WITH V <br />WALL "ARMAFLEX", OR EQUAL. <br />13. PROVIDE ISOLATION VALVES AT ALL FIXTURES. <br />VALVES SHALL BE CHROME FINISH. <br />14. ALL KITCHEN, PREP AREA AND SALES AREA <br />EQUIPMENT WILL BE FURNISHED AND INSTALLED BY <br />KITCHEN EQUIPMENT SUPPLIER EQUIPMENT WILL BE <br />FURNISHED WITH TRIM, FAUCETS, ESCUTCHEONS, ETC. <br />PLUMBING CONTRACTOR SHALL PROVIDE ALL <br />ROUGH -IN TRAPS AND MAKE ALL FINAL CONNECTIONS <br />(SEE EQUIPMENT SCHEDULE). <br />15. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL <br />ALL GAS PIPING AND MAKE ALL FINAL CONNECTIONS. <br />lro. THIS CONTRACTOR SHALL PROVIDE AND INSTALL ALL <br />PIPE HANGERS, AND SUPPORTS IN ACCORDANCE WITH <br />THE LOCAL APPLICABLE CODES. <br />I-1. PLUMBING CONTRACTOR TO PROVIDE BACKFLOW <br />PREVENTERS AT ALL COFFEE MAKERS, BAGEL OVEN, <br />DIPPING WELLS, ICE MAKER AND ALL OTHER <br />EQUIPMENT AS REQUIRED BY CODE. <br />18. PLUMBING CONTRACTOR TO PROVIDE TRAP PRIMERS <br />OR TRAP SEAL ON ALL FLOOR DRAINS AS PER <br />APPLICABLE CODE <br />IS. ANY CUTTING OR PATCHING NECESSARY TO PERMIT <br />THE INSTALLATION OF ANY WORK UNDER THIS <br />CONTRACT SHALL BE THE RESPONSIBILITY OF THIS <br />CONTRACTOR <br />20. ENTIRE INSTALLATION SHALL BE GUARANTEED FREE <br />OF DEFECTS AND CONTRACTOR SHALL REPAIR <br />AND/OR REPLACE ANY DEFECTIVE MATERIALS OR <br />EQUIPMENT AT NO COST TO THE OWNER FOR A PERIOD <br />OF ONE YEAR FROM THE DATE OF ACCEPTANCE BY <br />ENGINEER <br />21. ALL WORK SHALL BE SUBJECT TO THE APPROVAL OF <br />THE ARCHITECT / OWNER <br />22. DEVIATION FROM MATERIALS, METHODS, OR <br />PROCEDURES SET FORTH HEREIN MUST BE <br />APPROVED, IN WRITING, BY ENGINEER PRIOR TO <br />SUBMISSION OF BID, ORDER, FABRICATION OR <br />INSTALLATION. ANY AND ALL QUESTIONS AS TO THE <br />INTENT OF OR PROCEDURES SET FORTH IN THESE <br />DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF <br />THE ENGINEER PRIOR TO SUBMISSION OF A BID. LACK <br />OF KNOWLEDGE OR UNDERSTANDING OF THE PLANS <br />SHALL NOT JUSTIFY ANY CLAIMS OR ADDITIONAL <br />COMPENSATION. <br />23. PROVIDE THERMOSTATIC MIXING VALVES AT ALL <br />LAVATORIES AND HAND SINKS, SET AT NO MORE THAN <br />110°F. <br />FLUM51NG LEGEND <br />SANITARY <br />GREASE WASTE GW <br />COLD WATER — <br />HOT WATER — — <br />FILTERED WATER <br />FILTERED WATER UNDER SLAB --- <br />REVISIONS <br />BY <br />00 <br />u �- <br />d o <br />p E <br />c <br />qn <br />E <br />N ^ 00 C <br />Q C L <br />G V • � t3 <br />ti > <br />E <br />¢ � c <br />ps� <br />> a 3 <br />Y <br />A G <br />� o <br />c <br />w <br />a <br />oQ � as o00 <br />0 0 PAA <br />O <br />e PE 141 0 <br />° <br />° <br />° <br />STATE <br />aoo°�3 00 ° <br />0����000000000�0 <br />GARLAND PATTERSON, P.E. <br />FL Lic. No.: 14175 <br />DULY 26, 2022 <br />N N <br />1J m pNp N <br />Z ;gW, C4 p <br />�,,,nZ <br />(nMd ri v <br />Q O Z Cq <br />L <br />j� m x 0 <br />O m �300N <br />LL O N <br />ico <br />UNV cr• <br />Oong.0 <br />g� t <br />a <br />L <br />O <br />4- <br />40 <br />v ° L <br />O <br />w <br />C <br />E c <br />Z - .0 ° <br />Lm0 <br />X � <br />W h <br />O a° <br />T <br />• <br />t <br />C <br />Date: 07. 26. 22 <br />Scale: AS NOTED <br />Project Mgr: JR <br />Drawn: BMD <br />Job: 21-202 <br />Sheet <br />p 1 <br />