fi�Ll�M�3 I1�iC-� SPEC IF I C�4T IONS
<br />DIVISION 22 -PLUMBING
<br />SECTION 22 1000
<br />PLUMBING
<br />PART I - GENERAL
<br />1.1 WORK INCLUDED
<br />A FURNISH ALL LABOR MATERIAL AND EQUIPMENT NECESSARY FOR THE COMPLETE INSTALLATION OF
<br />THE SANITARY SEWER SYSTEM (INCLUDING SOIL AND VENT PIPING), WATER SERVICE, WATER METER
<br />TAP VALVES, BOXES, AND COLD AND HOT WATER SUPPLY SYSTEM INCLUDING ALL REQUIRED 140
<br />DEGREE PIPING, ALL REQUIRED GAS PIPING, HOT WATER HEATER PLUMBING FITTINGS AND FIXTURES,
<br />AND ALL RELATED FITTINGS AND CONTROLS, CONNECTING OF ALL KITCHEN AND SERVICE AREA
<br />EQUIPMENT PROVIDED BY LESSEE OR FRANCHISE OWNER AND ALL OTHER WORK REQUIRED FOR A
<br />COMPLETE SYSTEM AS DETAILED ON THE DRAWINGS OR SPECIFIED IN THIS SECTION.
<br />B. IN AREAS LLMERE NATURAL GAS 15 NOT AVAILABLE, FURNISH AND INSTALL L.P. GAS PIPING AND TANKS,
<br />12 PERMITS AND INSPECTIONS
<br />34 GAS PIPING
<br />23 ROOF FLASHING
<br />A ALL WORK SHALL BE INSTALLED IN STRICT ACCORDANCE WITH STATE, COUNTY AND
<br />A CONNECT TO ALL EQUIPMENT REQUIRING GAS SERVICE WITH A SHUT-OFF COCK AND DRIP AT EACH
<br />MUNICIPAL ORDINANCES AND REGULATIONS.
<br />A. CAP FLASHING FOR ROOF VENTS SHALL BE GALVANIZED METAL SLEEVE, OVERLAPPING 4 IN. ON
<br />FIXTURE LOCATION.
<br />B. ALL PERMITS AND ICES SHALL BE APPLIED AND PAID FOR UNDER THIS SECTION, INCLUDING ALL
<br />EXTERIOR AND TURNED 2' INTO STACK AND CLOSELY FITTED INTO INTERIOR SURFACE OF STACK t0
<br />B. CONNECTIONS INCLUDE, BUT ARE NOT LIMITED TO, HEATING AND AIR CONDITIONING UNIT, HOT WATER
<br />REQUIRED INSPECTIONS FOR WATER GAS AND SANITARY DRAINAGE SYSTEMS, REQUIRED WATER
<br />AVOID REDUCING OPENING SIZE UNNECESSARILY. A 16 OZ COPPER FLASHING SHALL BE PROVIDED
<br />HEATER FRYERS AND OVER.
<br />METER AND ALL TAPS TO WATER MAMA AND CONNECTIONS TO SEWERS.
<br />AROUND THE PIPE AND FLASHED INTO THE SINGLE PLY ROOFING. COORDINATE GAP FLASHING WITH
<br />C. PITCH PIPING FOR DRAINAGE AND INSTALL DRIP AND DIRT LEGS AT ALL LOW POINTS.
<br />13 LESSEE'S OR FRANCHISE OWNER'S EQUIPMENT
<br />SECTION 01531 EPDM ELASTOMERIC MEMBRANE ROOFING.
<br />D. MAKE FINAL CONNECTIONS TO EACH FRYER AND OVEN WITH HEAVY DUTY, COMMERCIAL
<br />2.4 HOT WATER HEATER
<br />TYPE, FLEXIBLE METAL CONNECTOR COMPLETE WITH QUICK CONNECT -DISCONNECT GAS MATE
<br />A MAKE FINAL CONNECTIONS TO ALL LESSEE'S OR FRANCHISE OWNER'S EQUIPMENT AND FURNISH AND
<br />NOTE. SPECIFICATIONS PROVIDE GENERAL GUIDANCE FOR HOT WATER HEATERS. THE CONTRACTOR
<br />COUPLING, CONSISTNG OF BRASS SOCKET AND
<br />INSTALL ANY FITTINGS OR INCIDENTAL ACCESSORIES THAT MAY BE NECESSARY BY JOB CONDITIONS
<br />SHALL CONSULT DRAWINGS, LOCAL HEALTH DEPARTMENT REVIEW OF DRAWINGS BEFORE ORDERING
<br />BRASS PLUG. FLEXIBLE CONNECTOR AND COUPLING SHALL BE AS MANUFACTURED BY HANSEN
<br />OR THAT MAY BE REQUIRED BY LOCAL BUILDING OR HEALTH CODES FOR COMPLETING FINAL
<br />WATER HEATER IF A VARIATION EXISTS BETWEEN THE SPECIFICATIONS AND ANY OF THE OTHER
<br />MANUFACTURING COMPANY.
<br />CONNECTIONS AND MAKING EQUIPMENT BEADY FOR OPERATION
<br />REFERENCES MENTIONED, CONTACT THE ARCHITECT BEFORE PLACING ORDERS FOR EQUIPMENT.
<br />E. CONNECTOR SHALL BE A FACTORY ASSEMBLED INTEGRAL UNIT, CONSISTING OF AN INNER LINER OF
<br />1.4 UCONNECTIO UTILITIES
<br />CONVULATED 85/15 RED BRASS TUBING, WITH AN OUTER FLEXIBLE CASING OF INTERLOCKED STRIP
<br />ATANKLESS HOT WATER HEATER SYSTEM IS AVAILABLE MANUFACTURED BY RINNAI - 'INTEGRITY" MODEL
<br />WOUND GALVANIZED STEEL
<br />A DIMENSIONS FOR ALL UNDER -SLAB UTILITIES ARE CRITICAL FOR LATER EQUIPMENT INSTALLATION
<br />(CONTACT 800-621-9419). 15,000 TO 1800W STUN CAPACITYi DIRECT ELECTRONIC 1GNITIONi 5 -
<br />F. MINIMUM LENGTH OF CONNECTOR SHALL BE 24 IN.
<br />CROSS-REFERENCE ALL DRAWINGS WITH THIS WORK, INCLUDING ALL ELEVATIONS, SHOWING
<br />85 GPM (DEPENDENT ON TEMPERATURE RINSk 14U X 2414 X 9'Di NATURAL GAS OR PROPANE3
<br />G. UNCOUPLNG SHALL CAUSE INSTANT AUTOMATIC SHUT-OFF OF GAS SUPPLY.
<br />DIMENSIONAL LOCATION OF THIS WORK
<br />PROVIDE DIRECT VENT FOR INTERIOR MOUNTING - NO VENT REQUIRED FOR EXTERIOR MOUNT.
<br />H. CONNECTOR AND COUPLING SHALL BE SIZED, TO DELIVER THE REQUIRED BTU RATING TO THE
<br />COORDINATE EXACT MODEL ! FLOW AND • OF REQUIRED UNITS W/ MANUFACTURER BASED ON STORE
<br />RESPECTIVE EQUIPMENT.
<br />PART 2 -PRODUCTS
<br />TYPE, STORE SIZE, STORE LOCATION AND ALL LOCAL CODE REQUIREMENTS FOR HOT WATER SYSTEMS
<br />I. FURNISH AND INSTALL A MECHANICAL GAS SHUT-OFF VALVE (SIZED TO PIPE). THE VALVE WILL BE
<br />2.1 MATERIAL
<br />B. AS AN ALTERNATE, FURNISH AND INSTALL A HOT WATER HEATER AS NOTED ON THE PLUMBING
<br />INSTALLED IN THE GAS LINE BEFORE THE FR1rER(S) AND/OR OVEN(S) AS INDICATED ON T1 E DRAWINGS.
<br />DRAWINGS TO BE EQUAL TO OR EXCEED THE FOLLOWING REQUIREMENTS:
<br />THE OPERATING HOOK-UP OF THE VALVE WILL BE DONE BY THE INSTALLER OF THE AUTOMATIC FIRE
<br />A WATER PIPING ABOVE GRADE SHALL BE TYPE 19" HARD DRAWN COPPER TUBING, WITH WROUGHT
<br />1. FOR FULL PRODUCING SHOPS' PROVIDE A HOT WATER HEATER UNIT THAT WILL PROVIDE
<br />15-GALLON TEMPERA WITH AN INPUT RATING OF WITH A RECOVERY A7
<br />EXTINGUISHING SYSTEM.
<br />COPPER FITTINGS, PIPING BELOW GRADE SHALL BE TYPE K" SOFT COPPER TUBING, WITH FLARED
<br />MENU ACB.T.U.
<br />:-GAS F
<br />10-DEGREE TEMPERATURE RISE. RECOMMENDED MANUFACTURER FORGES FUELED:
<br />FITTINGS. SIZES ARE SHOWN ON PLUMBING DRAWINGS. PIPING SHALL BE MADE UP WITH SWEAT FITTINGS.
<br />STATE:
<br />35 FINAL CONNECTIONS
<br />SOLDER SHALL BE 95-50 TYPE. THE ENTIRE LENGTH OF ALL TYPE K" PIPING UNDER THE SLAB AND
<br />:BT 80
<br />AD. SMITH:
<br />PENETRATING THROUGH THE SLAB WILL BE INSTALLED IN THE 1/2 IN. THICK ARMAFLEX ININSULATION.A
<br />RHEEM: G15-15. 15.
<br />COMPLETE THE FINAL CONNECTIONS OF EQUIPMENT SUPPLIED BY THE LESSEE OR FRANCHISE OWNER
<br />B. BUILDING SEWER AND ALL UMDEWxROUMD DRAINAGE AND VENT LINES SHALL BE SIZED AS SHOWN ON
<br />IMMEDIATELY UPON ITS DELIVERY IN PLACE.
<br />DRAWINGS, OR AS REQUIRED BY LOCAL CODES. THEY SHALL BE STANDARD WEIGHT HUB AND SPIGOT
<br />ELECTRIC:
<br />B. FROM CHROME SHUT-OFF VALVES ON BACK BAR WALLi PROVIDE COPPER PIPING TO BACK BAR
<br />CAST IRON PIPE AND NEOPRENE GASKET FITTINGS, UNLESS OTHERWISE SHOWN OR NOTED. SERVICE
<br />STATE: CS5-82-18-IFE
<br />EQUIPMENT. SOME EQUIPMENT REQUIRES FLARE FITTINGS - COORDINATE WITH EQUIPMENT
<br />WEIGHT CAST IRON PIPE, IF ALLOWED BY LOCAL CODES, MAY BE USED, IF ALLOWED BY LOCAL
<br />AA. SMITH: DVE-80
<br />SPECIFICATIONS.
<br />CODES, FROM 10 FT. OUTSIDE THE BUILDINGS, SEWER MAY BE VITRIFIED CLAY SEWER PIPE WITH AMVIT
<br />p4EEM: ELD-80.
<br />JOINTS OR TRANSITE PIPE. MINIMUM SIZE OF PIPES TO BE 4 IN.
<br />2. IN AREAS WHERE WATER HAS A HIGH LIME CONCENTRATION, BE SURE TO USE A UNIT THAT IS
<br />END OF SECTION
<br />C. VENTS ABOVE GRADE SHALL BE AS SHOWN ON DRAWINGS AND SHALL BE HUBLESS CAST IRON PIPE
<br />SPECIALLY DESIGNED TO REDUCE LIME DEPOSITS.
<br />FITTINGS AND CONNECTORS. IF PERMITTED BY LOCAL CODES, TYPE DWV COPPER MAY BE USED WITH
<br />3. FOR SATELLITE SHOPS OR SHOPS WITH NO PRODUCTION FACILITIES USE A UNIT THAT WILL
<br />DWV FITTINGS.
<br />PROVIDE A MINIMUM 50-GALLON STORAGE WITH AN INPUT RATING OF 60000 BT.U/HOUR WITH AN 80
<br />D. ADJUST, IF NECESSARY, SIZES OF GAS PIPING WITH LOCAL GAS COMPANY CHARACTERISTICS TO
<br />GPU4. AT 10 DEGREE TEMPERATURE RISE:
<br />DELIVER THE SPECIFIED BTU'S AT THE FIXTURE. PIPING SHALL BE BLACK STEEL, SCHEDULE 40, WITH
<br />GAS FUELED:
<br />WATER FILTER SYSTEM
<br />SCREWED MALLEABLE IRON FITTINGS.
<br />E. FURNISH AND INSTALL A MECHANICAL GAS VALVE (SIZED TO PIPE) FOR INSTALLATION IN THE GAS LINE
<br />- AA. SMITH: BT 65
<br />ELECTRIC:
<br />SECTION 22 6000
<br />TO THE FRYER(S) AND OVEN(S) AS PER SECTION 3.04 GAS PIPING, PARAGRAPH I.
<br />STATE: C40-52-12-IFE
<br />F. CONDENSATE IUD. DRIP DRAINS SHALL BE HUB DRAINS, FLOOR DRAIN WITH OPEN FUNNEL TYPE, OR
<br />A.O. SMITH: DVE-51
<br />FLOOR SINK WITH INTEGRAL TRAP, AS SHOWN ON DRAWINGS OR AS REQUIRED BY CODE, AS
<br />RHEEM: ELD-52
<br />PART I - GENERAL
<br />MANUFACTURED BY THE JOSAM COMPANY OR
<br />JAY R. SMITH, INC. ALL CONDENSATE DRAIN LINES FROM EQUIPMENT t0 DRAIN SHALL BE PVC.
<br />C. FURNISH AND INSTALL A SEPARATE 6 GALLON ELECTRIC HOE WATER HEATER FOR THE RESTROOMS IF
<br />I.1 WORK INCLUDED
<br />G. KITCHEN FLOOR SINKS PS" AS REQUIRED SHALL BE "AM MANUFACTURING COMPANY, SERIES NO.
<br />NOTED ON THE PLUMBINIG DRAWINGS TO BE EQUAL TO OR EXCEED THE FOLLOWING PRODUCTS:
<br />49000 WITH HALF -GRATE, NICKALOT TOP AND SEDIMENT BUCKET. ALL OTHER FLOOR DRAINS TV" TO
<br />A.O. SMITH: DEL-6
<br />A FURNISH ALL LABOR MATERIAL AND EQUIPMENT NECESSARY FOR THE INSTALLATION OF A STORE -WIDE
<br />BE JOSAM NO.30OW-A ALL EXPOSED PARTS TO BE OF NICKEL BRONZE FINISH.
<br />STATE: PCE 6 10MSA
<br />FILTRATION SYSTEM, TO BE INSTALLED AFTER THE METER AND BACKPLOW PREVENTOR SITE SPECIFIC
<br />CONDITIONS MAY REQUIRE THAT A REVERSE OSMOSIS SYSTEM BE INSTALLED, REFER TO DUNtlKIN
<br />22 FIXTURES
<br />25 FLUE
<br />BRANDS DESIGN GUIDANCE DOCUMENTS AVAILABLE ON THE EXTRANET FOR DIAGRAMMATIC
<br />DESCRIPTIONS OF BOTH: (REFER TO DRAWINGS FOR TYPE 4 LOCATION)
<br />A.UUATER CLOSET
<br />Q'' FURNISH AND INSTALL, UNDERWRITERS' LABORATORIES APPROVED, 5 IN. DIAMETER 'MEEAI-BASTOS"
<br />1. WATER CLOSET SHALL BE AMERICAN STANDARD ELONGATED CADET 3 FLOWISE
<br />TYPE B, FLUE FOR WATER HEATER EXTEND FLUE TO 6 FT. ABOVE ROOF / AS PER LOCAL CODE
<br />PART 2 - PRODUCTS
<br />TRI1
<br />RIGHT HEIGHT MODEL NO. 21AMERIC (LEFT TRIP) 215AA.105 (RIGHT TRIP) WITH
<br />NO
<br />REQUIREMIENTS. PROVIDE TALL CONE ROOF FLASHING, STORM COLLAR AND METALBESTOS TOP. THE
<br />ELONGATED EMOD L SOLID PLASTIC OPEN FRONT SEAT NO. 016 IN WHITE,
<br />DOUBLE WALL METAL VENT FLUE SHALL HAVE AN OUTER CASING OF GALVANIZED STEEL WITH A
<br />WITHOUT COVER AND SUPPLY.
<br />MINIMUM OF 0028 GAUGE OR 0,018 IN. THICKNESS, AND AN NITER CASING OF ALUMINUM. THE VENT
<br />11 FILTER INSTALLATION
<br />2. ALTERNATE WATER "HANDS FREE" CLOSET SHALL BE AMERICAN STANDARD
<br />SHALL BE LABORATORY -TESTED AND LISTED BY THE UNDERWRITERS' LABORATORIES.
<br />MADERA FLOWISE 161/211 HEIGHT MODEL NO. 3043DO1 WITH SLOAN REGAL
<br />A FILTRATION SYSTEM TO BE INSTALLED AS PER MANUFACTURER'S REQUIREMENTS AND SPECIFICATIONS.
<br />MANUAL 128 GPF FLUSNOMETER 111.128 (3180046), OR SLOAN 128 GPF SELECTRONIC
<br />2.6 AUTOMATIC FIRE EXTINGUISHING SYSTEM
<br />B. FILTRATION SYSTEM TO BE AS MANUFACTURED BY 3M OR EVERPURE - REFER TO NATIONAL
<br />AC POWER FLUSHOMETER 8111-128 (31SO011)
<br />ACCOUNT SOURCE INFORMATION.
<br />A THE INSTALLER WILL HOOK-UP THE MECHANICAL GAS SHUT-OFF VALVE, FURNISHED AND INSTALLED BY
<br />B.LAVATORY
<br />THE PLUMBER BEFORE THE FRYER(S) AND/OR OVEN(S), TO THE AUTOMATIC FIRE EXTINGUISHING
<br />22 SERVICE
<br />I. LAVATORY SHALL BE AMERICAN STANDARD LUCERNE, 201/2" BY 1814". NO. 355.012
<br />SYSTEM, SEE SECTION 155M
<br />FOR CONCEALED ARMS NO. 100-E BY J. R SMITH CO. (MASSACHUSETTS USE
<br />AUTOMATIC FIRE EXTINGUISHING SYSTEM.
<br />A IT IS THE RESPONSIBILITY OF THE FRANCHISEE TO PROVIDE A CONTINUOUS SERVICE
<br />MODEL OB141.011 COMPLETE WITH NO. 1140 ZURN FAUCET WITH GRID DRAIN, 3611 CHROME
<br />CONTRACT FOR THE ONGOING MAINTENANCE OF THE WATER CONDITIONING SYSTEM. FILTER TO BE
<br />SUPPLIES WITH ANGLE STOPS, ADJUSTABLE 11PII BRASS TRAP TO SUIT GRID DRAIN,
<br />PART 3 -EXECUTION
<br />REPLACED AS PER MANUFACTURER'S RECOMMENDATION OR WHEN THE GAUGE INDICATES LOW WATER
<br />TUBING DRAIN TO WALL, 11411 INLET, 11i2" OUTLET, ESCUTCHEON - CHROME FINISH.
<br />PRESSURE.
<br />OPERATION PROVIDE FAUCET BY SLOAN - "HANDS FREE"
<br />3.1 INSTALLATION
<br />2. FOR ALTERNATE "HANDS FREE" OPERATION PROVIDE FAUCET BY SLOAN -
<br />OPTIMA «ETF-600 WITH TRANSFORMER "EL-154 AND AERATOR OETEF-1024-A.
<br />A ALL PIPING AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE DRAWINGS AND SHALL
<br />3. ALL LAVATORY FAUCETS TO BE EQUIPPED WITH LOCKABLE REMOVABLE
<br />COMPLY WITH ALL APPLICABLE CODES, PARTICULARLY HEALTH AND PLUMBING, AND STANDARDS OF
<br />END SECTION
<br />AERATORS.
<br />GOOD PRACTICE.
<br />B. VERIFY INVERTS OF SEWER AND DRAINAGE CONNECTIONS BEFORE INSTALLING SEDER LINES.
<br />C. MOP SINK
<br />1. FURNISH ONE MOLDED CONSTRUCTION ONE PIECE MOP SERVICE BASIN AS MANUFACTURED BY EL
<br />32 WATER SUPPLY LINES
<br />MUSTEE 4 SONS, MODEL NO.63M, COMPLETE WITH DRAIN BODY, STRAINER AND LINT BASKET.
<br />FITTINGS SHALL BE MOEN COMMERCIAL NO.8230 (CHROME). PROVIDE CLICK AND CLEAN
<br />A WATER SERVICE, LOCATED AS SHOWN ON SITE DRAWING, SHALL BE INSTALLED AND TESTED AS
<br />DISPENSING SYSTEM BY KAY CHEMICAL COMPANY AT MOP SINK REFER TO NATIONAL ACCOUNT
<br />REQUIRED BY THE LOCAL UTILITY COMPANY. SERVICE TO BE 1- 1/2" IN. MIN", TYPE K" COPPER OR
<br />SOURCE INFORMATION FOR COMPLETE DETAILS.
<br />AS INDICATED ON DRAWINGS.
<br />B. PIPING SHALL BE OF MINIMUM SIZES SHORN ON DRAWINGS.
<br />OPTIONAL URINAL AMERICAN STANDARD WASHBROOK FLOWISE 05 GF'F HIGH EFFICIENCY URINAL
<br />C. PROVIDE VALVES ON ALL LINES AS 5HOWN ON DRAWINGS AND ON UP -STREAM AND DOWN -STREAM
<br />%590.001 MANUAL FLUSH (STANDARDh SLOAN 186-05 (3162655) REGAL I86-1
<br />SIDE OF WATER METER EACH FIXTURE SHALL HAVE SEPARATE STOP AND WASTE VALUES AND ALL
<br />AUTOMATIC FLUSH (OFTIONALh SLOAN 8186-05 (3190068) TOUCHFREE OPERATION, METAL COVER
<br />PIPING SHALL BE CONCEALED EXCEPT AS OTHERWISE INDICATED ON DRAWINGS. WHERE WATER PIPES
<br />OVERRIDE BUTTON 4 FLUSHO METER BODY LESS HANDLE OPEMNER
<br />AND VALVES ARE EXPOSED IN FINISHED SALES AND TOILET ,AREAS, PIPING SHALL BE THREADED
<br />'WATERLESS' URINAL (OPTIONAL - DO ELITEh
<br />CHROME AND SHALL HAVE CHROME PLATED ESCUTCHEONS AND VALVE AS REQUIRED. KITCHEN AND
<br />WORK AREAS MAY BE COPPER
<br />D. BACK BAR FITTINGS AND EXPOSED PIPE TO BE CHROME PLATED. STOP VALVES BY AMERICAN
<br />D. HOSE 51555 SHALL BE INSTALLED AS INDICATED ON THE DRAWINGS AND SHALL HAVE SEPARATE 3/4
<br />STANDARD.
<br />IN. MAIN FEED. WHEN SERVING EXTERIOR AREAS, HOSE BIBBS SHALL BE FROST -PROOF TYPE WITH
<br />E. IN KITCHEN, FURNISH AND INSTALL THREE COMPARTMENT POT SINK UNIT AND DRAIN BOARDS AS
<br />REMOVABLE KEY HANDLE. FASTEN SECURELY TO WALL. INSTALL 18 IN. ABOVE FINISH SLAB.
<br />REQUIRED BY LOCAL CODES, NSF STANDARDS AND AS SPECIFIED:
<br />E. STANDARD AIR CHAMBERS, 20 DIAMETERS OF PIPE HIGH, AND ONE SIZE LAIR SHALL BE
<br />I. COMPARTMENT SIZE, DRAM BOARD SIZE AND TOTAL DIMENSIONS AS SHOWN ON DRAWINGS.
<br />PROVIDED ABOVE EACH FIXTURE OUTLET AND AS REQUIRED ELSEWHERE. IF LINE PRESSURE IS
<br />REFER TO EQUIPMENT SPECIFICATIONS FOR SINK FABRICATION. EACH COMPARTMENT TO HAVE
<br />GREATER THAN 60 POUNDS AT WATER METER OUTLET,
<br />KOHLER 08801 BRASS WASTE OUTLET, CHROME PLATED, SATIN FINISH, WITH A 3-1/2 IN. DIAMETER
<br />A PRESSURE REDUCING VALVE SHALL BE PROVIDED AND INSTALLED, SET AT 60 POUNDS PRESSURE
<br />STAINLESS STEEL, PERFORATED, FLUSH STRAINER PLATE, THREADED FOR CONNECTION TO A 2 IN.
<br />FOR THE COMPLETE SYSTEM. ON THE COLD WATER SUPPLY LINE TO THE ICE MACHINE, INSTALL PRV
<br />DRAIN LINE.
<br />AND SET AT 20 POUNDS PRESSURE.
<br />2, FITTINGS SHALL BE T 4 S 5-133 PRE -RINSE SPRAY WITH 8-101C SPRAY HEAD, 15-109 WALL
<br />PRESSURE GAUGE TABS SHALL BE PROVIDED. COMPLETE SYSTEM SHALL BE TESTED AS REQUIRED
<br />BRACKET, 8-156 ADF ADD -A -FAUCET WITH 12 IN. NOZZLE AND SPECIAL 4 IN. CHROME NIPPLE. 8-231
<br />BY APPLICABLE CODES.
<br />SINK MIXING FAUCET FOR THREE COMPARTMENT SINK
<br />F. MINIMUM TESTING OF WATER PIPING - MAINTAINS 15 PSI OF AIR PRESSURE WITHIN THE ENTIRE SYSTEM
<br />3. DRAIN SHALL INCLUDE ROTARY WASTE VALVE SIMILAR TO T 4 S MODEL 53901 WITH EXTENDED
<br />FOR A PERIOD OF NOT LESS THAN 15 MINUTES. PROVIDE A THERMOSTATIC MIXING VALVE ON HOT
<br />HANDLE AND SNAP -IN STAINLESS STEEL STRAINERS. FITS DRAIN OPENING OF 3 1/2 INCHES TO 4 1/2
<br />WATER SERVICE TO TOILET LAVATORIES, BRADLEY OTMA OR LEONARD 0210.
<br />INCHES.
<br />G INSULATE ALL PIPING IN SPACES SUBJECT TO FREEZING WITH 1-1/2 IN, PIPE INSULATION AS SPECIFIED
<br />4. NOTE: SMALLER THREE COMPARTMENT SINKS MAY BE ALLOWED PROVIDED THE SINK
<br />ABOVE. ALL PIPING SHALL BE PROPERLY SUPPORTED WITH HANGERS OF COMPATIBLE MATERIAL
<br />COMPARTMENT CAN ACCOMMODATE THE LARGEST EQUIPMENT ITEM THAT WILL REQUIRE WASHING,
<br />AND ALL WATER PIPES PASSING THROUGH CONCRETE 514ALL BE WRAPPED WITH AN APPROVED
<br />RINSING, AND SANITIZING. SINK SPECIFICATION FOR GAUGE, TYPE OF STAINLESS STEEL AND FINISH
<br />PLASTIC TAPE TO PREVENT CHEMICAL ACTIONS.
<br />SHALL BE THE SAME AS LARGER THREE -COMPARTMENT SINK LISTED BELOW.
<br />H. FINAL WATER CONNECTIONS TO PROOFERS SHALL BE AS SHOWN ON EQUIPMENT SPECIFICATIONS.
<br />5. PROVIDE CLICK AND CLEAN DISPENSING SYSTEM BY KAY CHEMICAL COMPANY AT
<br />THREE -COMPARTMENT POT SINK REFER TO NATIONAL ACCOUNT SOURCE INFORMATION FOR
<br />33 SANITARY SEWER SYSTEM
<br />COMPLETE DETAILS
<br />A SEWER SYSTEM SHALL BE INSTALLED AND TESTED IN ACCORDANCE WITH ALL APPLICABLE CODES
<br />G. ON '/2 IN. DOMESTIC COLD WATER CONNECTION TO PROOFER(S), PROVIDE AN WATER FILTRATION
<br />AND AS INDICATED ON THE DRAWINGS AND SPECIFICATIONS,
<br />SYSTEM. SEE PLAN FOR SPECIFIC REQUIREMENTS.
<br />B. WHEN HOUSE TRAP AND FRESH AIR INLET IS REQUIRED BY CODE, TRAP SHALL HAVE BRASS
<br />H. RIFNIS14 AND INSTALL AS REQUIRED BY LOCAL OR STATE HEALTH AND PLUMBING CODES, THE
<br />CLEANOUT PLUGS FLUSH WITH FLOOR
<br />FOLLOWING ITEMS OR EQUIPMENT:
<br />C. VENTS SHALL BE SIZED AS SHOWN, OR AS REQUIRED OR PERMITTED BY LOCAL CODES, AND SHALL
<br />1. GREASE TRAPS 'GT" SHALL BE JOSAM 60100 ON -FLOOR MODEL OR 60130 RECESSED TYPE
<br />PROJECT ABOVE ROOF A MINIMUM OF 1 FOOT. ALL VENTS SHALL BE 3 IN. MN" DIAMETER THROUGH
<br />GREASE INTERCEPTOR, WITH FLOW CONTROL VALVE 25 GPM (WITH FLUSH FLOOR COVER REMOVABLE
<br />ROOF, (USE INCREASER IF NECESSARY)
<br />BUCKET AND TWIST LOCK HANDLE). WASTE FROM FOOD DISPOSAL SHALL NOT RUM THROUGH GREASE
<br />UNLESS CODES REQUIRE GREATER DIMENSION.
<br />TRAP. TOP COVER TO BE FLUSH WITH QUARRY TILE FLOOR IN ADDITION TO JOSAM SERIES 60100'
<br />D. SELLER PIPING SHALL BE PROPERLY SLOPED AND ALL REQUIRED FITTINGS, VENTS, TRAPS AND
<br />GREASE TRAP THAT IS USED WHEN ROUGH -IN CENTER 15 MORE THAN 6" BELOW SLAB 'JOSAM SERIES
<br />CLEANOUTS SHALL BE PROVIDED.
<br />60120" EXTENDED TOP 15 APPROVED. THIS ALLOWS ROUGHING TO 11" BELOW SLAB. REFER TO
<br />E. VERIFY INVERTS AT SEWER TAP AND BUILDING BEFORE STARTING INSTALLATION.
<br />LOCAL OR STATE HEALTH AND PLUMBING CODES FOR GREASE TRAP SIZE RESTRICTIONS. NOTE:
<br />F. MINIMUM TESTING OF WASTE PIPING - PLUG OPENINGS AND FILL THE ENTIRE SYSTEM TO THE TOP OF
<br />PROVIDE EXTERIOR GREASE TRAP OUTSIDE OF BUILDING WHERE POSSIBLE.
<br />THE VENTS WITH WATER AND ALLOW TO REMAIN At LEAST 30 MINUTES.
<br />2. INSTALL IMMERSION HEATER AND DIP BASKET FOR POT SINK
<br />Ii�i�iI110110110�1i�i��ll1
<br />REVISIONS
<br />BY
<br />co
<br />r, CXJ
<br />Y M
<br />s �
<br />u �-
<br />d .`ce
<br />E
<br />it o
<br />2 N u
<br />E r-- u
<br />r 2
<br />v
<br />cu
<br />.o
<br />d 0 3
<br />y > a 3
<br />3
<br />0
<br />c �
<br />iv
<br />E
<br />a,
<br />�
<br />o
<br />W
<br />a
<br />p G o
<br />PAP
<br />e PE 1417 °
<br />a
<br />0 O
<br />STATE OF
<br />a RIO "
<br />e��woovo'vi\ALa�pOp°°o
<br />GARLAND PATTERSON, P.E.
<br />FL Lic. No.: 14175
<br />JULY 26, 2022
<br />Um m�
<br />Z ui,
<br />Q N
<br />ILL �' � N
<br />UAL
<br />pp �
<br />Ofn V
<br />Wn
<br />L
<br />O
<br />y
<br />0 • y LL.
<br />Z
<br />O = w
<br />0
<br />Y 1>n E c
<br />Z - .0 7
<br />0 N
<br />LJ r" h
<br />Lo
<br />40
<br />d'
<br />O
<br />•
<br />t
<br />C
<br />Date: 07. 26. 22
<br />Scale: AS NOTED
<br />Project Mgr: JR
<br />Drawn: BIND
<br />Job: 21-202
<br />Sheet
<br />P6
<br />
|