DIVISION 26 - ELECTRICAL
<br />LEGEND
<br />DESCRIPTION:
<br />MOUNTING
<br />HEIGHT:
<br />REVISIONS I BY
<br />SECTION 26 W%W
<br />ELECTRICAL
<br />PART GENERAL
<br />IJ WORK INCLUDED
<br />AFURNISH ALL LABOR MATERIAL AND EQUIPMENT NECESSARY FOR THE COMPLETE INSTALLATION OF THE
<br />ELECTRICAL SYSTEM AS SHOWN ON THE DRAWINGS, INCLUDING FINAL CONNECTIONS TO LESSEE'S OR FRANCHISE
<br />OWNER'S EQUIPMENT AND SIGNS, AS SPECIFIED HEREIN, IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE,
<br />STATE ELECTRICAL CODE, THE REQUIREMENTS OF THE LOCAL UTILITY COMPANY, AND ALL APPLICABLE CODES
<br />AND LAWS.
<br />B_IT IS THE INTENT OF THIS SECTION OF THE SPECIFICATIONS AND ACCOMPANYING ELECTRICAL DRAWINGS TO
<br />REQUIRE THESE SYSTEMS TO BE FURNISHED COMPLETE IN EVERY RESPECT, FURNISH ALL WIRING AND
<br />EQUIPMENT NEEDED AND USUALLY FURNISHED IN CONNECTION WITH SUCH WORK, WHETHER SPECIFICALLY
<br />MENTIONED OR NOT,
<br />12 PERMITS
<br />A.PROCURE ALL NECESSARY PERMITS FOR WORK INSTALLED3 PAY ALL FEES AND CHARGES CONNECTED HEREIN
<br />DELIVER CERTIFICATES OF APPROVAL BY AUTHORITIES HAVING JURISDICTION OVER WORK, TO THE OWNER
<br />BEFORE THE WORK WILL BE FINALLY ACCEPTED.
<br />13 FRANCHISE OWNER'S EQUIPMENT AND SIGNS
<br />AMAKE FINAL CONNECTIONS TO ALL LESSEE's OR FRANCHISE OWNER'S SIGNS AND EQUIPMENT AND FURNISH AND
<br />INSTALL ANY FITTINGS OR INCIDENTAL ACCESSORIES THAT MAY BE NECESSARY OR THAT MAY BE REQUIRED
<br />BY LOCAL CODES FOR COMPLETING FINAL CONNECTIONS AND MAKING EQUIPMENT READY FOR OPERATION.
<br />B.COORDINATE WITH THE APPROVED SIGN INSTALLATION COMPANY AND, IN CONJUNCTION WITH THE SIGN
<br />COMPANY, MAKE FINAL CONNECTIONS TO SIGNS AT THE TIME OF INSTALLATION.
<br />IA UNDER -SLAB UTILITIES
<br />A.DIMENSIONS FOR ALL UNDER -SLAB UTILITIES ARE CRITICAL. FOR LATER EQUIPMENT INSTALLATION. CROSS
<br />REFERENCE ALL DRAWINGS AND EQUIPMENT SPECIFICATIONS WITH THIS WORK INCLUDING THE ELEVATIONS
<br />sHOWING DIMENSIONAL. LOCATION OF ALL STUBS FOR EQUIPMENT_
<br />15 ALL -ELECTRICAL BUILDING
<br />AIN AREAS WHERE NO GAS SERVICE IS AVAILABLE AND ELECTRICITY IS REQUIRED FOR CooKING AND HEATING,
<br />ARCHITECT WILL FURNISH DRAWINGS FOR AN ALL -ELECTRIC BUILDING, WITH INCREASED SIZING OF ELECTRIC
<br />SERVICE AND EQUIPMENT TO SUIT.
<br />lb GUARANTEES AND INSTRUCTIONS
<br />AGUARANTEE ALL EQUIPMENT, SYSTEMS AND WORK FURNISHED AND INSTALLED UNDER THIS SECTION FOR A
<br />PERIOD of ONE (U YEAR FROM DATE OF SUBSTANTIAL COMPLETION THEREOF, AGAINST DEFECTS IN MATERIAL,
<br />DESIGN AND WORKMANSHIP.
<br />B.FAILURE OF ANY PART OR PARTS DURING GUARANTEE, OWING TO ABOVE CAUSES, SHALL BE REPLACED
<br />PROMPTLY UPON NOTICE BY ARCHITECT, WITHOUT CHARGE TO THE OWNER
<br />1_71 HEATING, VENTILATING t AIR CONDITIONING < LEssm,s OR FRANCHISE oWNER's EQUIPMENT
<br />A1;sFER TO SECTION woo FOR HEATING, VENTILATING t AIR CONDITIONING EQUIPMENT SELECTED AND MAKE
<br />WHATEVER ADJUSTMENTS TO WIRE SIZES, BREAKERS AND SWITCHES NECESSARY FOR PROPER OPERATION AND
<br />As PER CODE OR UTILITY COMPANY REQUIREMENTS_
<br />B.ELECTRICALLY OPERATED EQUIPMENT FURNISHED AND INSTALLED UNDER OTHER SECTIONS SHALL BE
<br />CONNECTED UNDER THIS SECTION, INCLUDING HEATING AND AIR CONDITIONING UNITS, EXHAUST FANS,
<br />THERMOSTATS, CONTROLS, ALL SIGNS, AND LESSEE'S OR FRANCHISE OWNER'S EQUIPMENT.
<br />(.REFER TO THE DRAWINGS AND PROVIDE ALL POWER AND CONTROL WIRING TO THE RooF TOP UNITS, HOOD
<br />EXHAUST FANS, ETC. CHECK WITH SECTION 15200 - HEATING, VENTILATING t AIR CONDITIONING, OBTAIN ALL
<br />INFORMATION PERTAINING TO THIS EQUIPMENT AND MAKE ALL FINAL CONNECTIONS AS REQUIRED.
<br />D.REFER TO THE DRAWINGS AND DO ALL WIRING FOR ALL EXHAUST FANS AS REQUIRED,
<br />PART 2 PRODUCTS
<br />2.1 SERVICE MATERIAL
<br />AARRANGE FOR AND INSTALL 30 AMP. MINIMUM TEMPORARY ELECTRICAL SERVICE, 120-208 VOLTS, 3-WIRE,
<br />SINGLE PHASE. REMOVE FROM SITE AFTER PERMANENT SERVICE IS OPERATING.
<br />B.FURNISH AND INSTALL 120-208 VOLTS, 3 PHASE, 4-WIRE, 60-1-ERTZ PERMANENT SERVICE. AMPERAGE As
<br />INDICATED ON DRAWINGS. MAIN SERVICE SWITCH TO BE SIZED AND FUSED COMPATIBLE WITH HEATING,
<br />VENTILATING < AIR CONDITIONING UNIT SIZE. (SEE DRAWINGS AND SECTION 15200 of SPECIFICATIONS FOR UNIT
<br />SIZE-)
<br />22 WIRES
<br />A.MINIMUM SIZE FOR BRANCH CIRCUIT WIRING SHALL BE NO. 12 AWG SOLID COPPER FOR 600 VOLT SERVICE.
<br />WHERE PERMITTED BY LOCAL CODE, NON-METALLIC SHEATHED CABLE TYPE NMC (ROIEX) WITH GROUND WIRE
<br />MAY BE USED, IF REQUIRED BY LOCAL CODE, USE BX ARMORED CABLE OR TYPE THHN WIRE ENCLOSED IN
<br />APPROVED METAL RACEWAYS. ALUMINUM WIRE SHALL NOT BE USED.
<br />23 CONDUIT
<br />A.UNDERGROUND CONDUITS FOR PYLON SIGN, AREA LIGHTING AND DRIVE-THRU MENU SYSTEM, AS INDICATED ON
<br />THE SITE DRAWING SHALL BE HEAVY WALL, SCHEDULE 40 PVC. CONDUIT SHALL BE GAPPED DURING
<br />CONSTRUCTION TO PREVENT ENTRANCE OF FOREIGN MATTER IF THE USE OF PVC IS NOT PERMITTED BY LOCAL
<br />CODES, ALL UNDERGROUND CONDUITS SHALL BE RIGID STEEL, HEAVY WALL GALVANIZED. CONDUIT FITTINGS
<br />EXPOSED TO WEATHER SHALL BE OF A TYPE APPROVED FOR sUCH USE AND SHALL BE PROVIDED WITH
<br />GASKETS OR OTHER MEANS OF EXCLUDING MOISTURE.
<br />B.CONDUIT CLAMPS SHALL BE of THE ONE SCREW MALLEABLE TYPE WITH MATCHING CLAMP BACKS, APPLETON
<br />ELECTRIC COMPANY OR PERFORMANCE EQUAL-
<br />C. "SWAB" CONDUIT DRY BEFORE PULLING WIRES_ THREADS SHALL BE PROTECTED. UNDERGROUND CONDUIT IN
<br />YARD RUNS SHALL BE LAID WITH 2 FT_ MINIMUM COVER OF SAND OR AS REQUIRED BY LOCAL CODE. WHERE
<br />REQUIRED BY LOCAL CODE, USE RIGID STEEL CONDUIT, HEAVY WALL GALVANIZED FOR ALL WORK WITHIN
<br />BUILDING. OTHERWISE, WHERE RACEWAYS ARE REQUIRED USE THINWALL ELECTRICAL METALLIC TUBING.
<br />D.SEALTITE CONDUIT AND FITTINGS SHALL BE USED FOR FINAL MOTOR CONNECTIONS. SMALLEST SIZE CONDUIT FOR
<br />BRANCH CIRCUIT WIRING SHALL BE '/2 INCH CONDUIT, UNLESS OTHERWISE NOTED.
<br />2A DISTRIBUTION
<br />A.SERVICE ENTRY EQUIPMENT AND DISTRIBUTION PANELS SHALL BE AS SPECIFIED AND DETAILED ON THE
<br />DRAWINGS, OR APPROVED EQUAL ONLY, IF AUTHORIZED IN WRITING BY THE ARCHITECT.
<br />BALL WIRING TO AND FROM PANEL BOARDS, INCLUDING MAIN SERVICE, TO BE RUN WITHIN THE 2 BY 6 WALL
<br />(CHASE) AS SHOWN ON THE DRAWINGS,
<br />25 SWITCHES AND OUTLETS
<br />AALL TOGGLE SWITCHES AND RECEPTACLES SHALL BE FLUSH WITH THE FINISH WALL, UNLESS SPECIFICALLY
<br />NOTED OTHERWISE,
<br />1_ INTERIOR FLUSH BOXES SHALL BE CODE GRADE STEEL, SECURELY FASTENED WITH APPROVED DEVICES TO
<br />STUDS OR MASONRY AND SHALL BE AS MANUFACTURED BY RACO, OR APPROVED EQUAL.
<br />2, TOGGLE SWITCHES SHALL BE TYPE 54521-2-1 (IVORY) AS MANUFACTURED BY LEVITON, INC, AND SHALL BE
<br />TUMBLER TYPE 20 AMP. QUIET TYPE.
<br />3, ALL INDOOR CONVENIENCE OUTLETS SHALL BE TYPE CR-15 I AS MANUFACTURED BY LEVIToN_ ALL
<br />CONVENIENCE OUTLETS IN THE SALES AND DINING AREAS, ARE TO BE BROWN IF LOCATED BELOW CHAIR
<br />RAIL. ALL OTHERS ABOVE CHAIR RAIL TO BE BONE,
<br />4. OUTLET AND SWITCH PLATES SHALL BE OF STAINLESS STEEL - LEVITOK
<br />2b LIGHTING FIXTURES AND EQUIPMENT
<br />ALIGHTING FIXTURES, INCLUDING LAMPS AND CLOCKS IN KITCHEN AND SALES AREA, SHALL BE As SPECIFIED AND
<br />DETAILED ON THE DRAWINGS. NO SUBSTITUTIONS WILL BE PERMITTED, UNLESS AUTHORIZED IN WRITING BY THE
<br />ARCHITECT.
<br />1. FURNISH AND INSTALL ALL LIGHTING FIXTURES AND LAMPS IN ACCORDANCE WITH THE FIXTURE SCHEDULE
<br />SHOWN ON DRAWINGS, COMPLETE WITH NECESSARY COMPONENTS, MOUNTING AND HANGING DEVICES
<br />REQUIRED TO INSTALL THE PARTICULAR FIXTURE IN ITS DESIGNATED LOCATION, COMPLETELY WIRED AND
<br />READY FOR OPERATION.
<br />2. KITCHEN FRYER EXHAUST HOOD WILL BE FURNISHED WITH TWO (2) VAPOR -PROOF FIXTURES. FURNISH AND
<br />INSTALL TWO (2) 'A" TYPE LAMPS IN THE FIXTURES. INSTALL FIXTURES COMPLETE WITH ALL ACCESSORIES
<br />SUCH AS CLOSE NIPPLES, EXTENSION COUPLINGS, CONNECTING STRAP AND SCREWS, LOCK NUTS, HICKEYS,
<br />PLASTER RINGS TO FORM A COMPLETE FIXTURE INSTALLATION FOR USE WITH ANY TYPE OF STANDARD
<br />OUTLET OR SWITCHBOX
<br />3. ALL FLUORESCENT FIXTURES SHALL BE SUPPORTED INDEPENDENT OF FURRED OR SUSPENDED CEILINGS TO
<br />THE BUILDING STRUCTURE,
<br />4, LAMPS SHALL BE LED, FLUORESCENT AND / OR INCANDESCENT AS INDICATED - 120 VOLT, SYLVANIA,
<br />WESTINGHOUSE, GENERAL ELECTRIC, OR APPROVED EQUAL. INCANDESCENT LAMPS SHALL BE RATED AT 130
<br />VOLTS DESIGN VOLTAGE.
<br />5. FLUORESCENT FIXTURE BALLASTS SHALL BE 'P" RATED, WITH POWER FACTOR, CBM-ETL CERTIFIED AND
<br />LISTED BY THE UNDERWRITERS' LABORATORIES. ALL BALLASTS TO HAVE INTEGRAL THERMAL PROTECTION
<br />WITH AUTOMATIC RESET, UNIVERSAL OR APPROVED EQUAL-
<br />6, REFER TO DRAWINGS FOR CEILING LAYOUT AND CONSTRUCTION.
<br />1, ALL SALES AREA LIGHTING TO HAVE WARM WHITE LAMPS. FURNISH AND INSTALL IN EACH TOILET ONE (1)
<br />ELECTRICAL HAND DRYER As MANUFACTURED BY EXCEL DRYER, INC. (As PROVIDED BY NEWTON
<br />DISTRIBUTION- SEE DBl NATIONAL ACCOUNTS), XL MODEL, WHITE METAL COVER WITH BRAND APPROVED
<br />MESSAGING, 110-12OV, 12B AMPS, 60 HZ,
<br />2,1 PANEL50ARDS
<br />DUNKIN' BRANDS HAS A NATIONAL ACCOUNT PROGRAM FOR PANEL50ARDS WITH VILLA LIGHTING. PLEASE
<br />CALL VILLA LIGHTING AT 800-325-ow AND/OR EMAIL DEANNA. MCCLANAHAN*VILLALIGHTING�COM.
<br />HALL PANELBOARDS SHALL BE DEAD -FRONT, SAFETY -TYPE EQUIPPED WITH SINGLE OR MULTI -POLE CIRCUIT
<br />BREAKERS, SPECIFIED IN THIS SECTION AND AS SCHEDULED ON THE DRAWINGS. ALL PANELBOARDS SHALL BE
<br />RECESSED WALL MOUNTED WITH A MINIMUM CAPACITY OF 42 CIRCUITS.
<br />B.PANELBOARDS SHALL BE SUITABLE FOR 120-208 VOLTS, THREE PHASE, FOUR WIRE OPERATIONS AS
<br />SCHEDULED ON THE DRAWINGS.
<br />C.ALL PANELBOARIDS SHALL HAVE A CIRCUIT DIRECTORY CARD MOUNTED IN A FRAME WITH PLASTIC COVER
<br />INSTALLED ON THE INSIDE OF THE DOOR ALL DIRECTORY CARDS SHALL BE PROPERLY FILLED IN 'TYPE
<br />WRITTEN" AND INDICATING AREAS AND DEVICES SERVED BY EACH CIRCUIT.
<br />D.ALL CIRCUIT BREAKERS SHALL BE BOLTED -TYPE, QUICK -MADE AND QUICK -BREAK TYPE OF MANUAL
<br />OPERATION, TRIP FREE, AND WITH INVERSE TIME CHARACTERISTICS SECURED THROUGH THE USE OF BIMETALLIC
<br />THERMAL -MAGNETIC TRIPPING ELEMENTS. ALL MULTI -POLE BREAKERS SHALL HAVE A SIMULTANEOUS TRIP.
<br />E.SINGLE POLE, DOUBLE AND THREE -POLE CIRCUIT BREAKERS FOR LIGHTING AND POWER PANEL BOARDS SHALL
<br />BE 240 VOLTS, TYPE THOM FROM 15 AMPS THROUGH 100 AMPS, HAVING NEMA INTERRUPTING CAPACITY NOT
<br />LESS THAN 100W AMPERES A.C. AT 240 VOLTS OR LESS.
<br />F. PANELBOARDS SHALL BE TYPE AQ PANEL BOARDS AS MANUFACTURED BY GENERAL ELECTRIC OR
<br />EQUAL, SQUARE "D" COMPANY, i T.E, WESTINGHOUSE OR PETERSON.
<br />G.CIRCUIT BREAKERS IN LIGHTING PANEL SHALL BE APPROVED 'SWITCHING TYPE" CIRCUIT BREAKERS.
<br />2.9 SAFETY SWITCHES AND FUSES
<br />DUNKIN' BRANDS HAS A NATIONAL ACCOUNT PROGRAM FOR SWITCHES t FUSES WITH VILLA LIGHTING. PLEASE
<br />CALL VILLA LIGHTING AT 800-325-OS6 AND/OR EMAIL DEANNA. MCCLANAHAN*VILLALIGHTINCjCOM.
<br />A.SAFETY SWITCHES SHALL BE OF THE FUSIBLE TYPE EQUIPPED WITH AN EXTERNAL LEVER OR HANDLE FOR
<br />MANUAL OPERATION WITH INTERLOCKING COVER
<br />B.NEUTRAL CONDUCTORS SHALL BE SOLID THROUGHOUT. SAFETY SWITCHES SHALL BE TYPE TH AS MANUFACTURED
<br />BY GENERAL ELECTRIC OR EQUAL: SQUARE "0" COMPANY, I.T.E. AND WESTINGHOUSE.
<br />CALL FUSES INSTALLED IN SAFETY SWITCHES THROUGHOUT THE CONTRACT SHALL BE NON-RENEWABLE DUAL
<br />ELEMENT TYPE. FUSES SHALL BE AS MANUFACTURED BY COULD SHAWMUT.
<br />PART 3 EXECUTION
<br />3J SERVICE INSTALLATION
<br />ASERVICE SHALL BE BROUGHT OVERHEAD TO REAR OF BUILDING WITHOUT CROSSING ROOF OF SHOP. PROVIDE
<br />GALVANIZED PIPE AND WEATHER HEAD IN SIZE AS SHOWN ON DRAWINGS, BOLTED TO WALL WITH THROUGH
<br />BOLTS AND PLATE WASHERS INSIDE (UNLESS OTHERWISE SHOWN ON DRAWINGS). PIPE TO EXTEND 8 FT. MINIMUM
<br />ABOVE ROOF AND 6 FT, ON WALL. PROVIDE ADDITIONAL SUPPORT TO MAST, EXTENDING ABOVE ROOF, IF
<br />REQUIRED, TO PREVENT BENDING. PIPE TO OFFSET IF NECESSARY FOR CLEARANCE of STRUCTURE.
<br />B.SEE SITE PLAN FOR UNDERGROUND SERVICE TO REAR OF BUILDING. INCLUDE ANY CHANGES REQUIRED IN THE
<br />ELECTRICAL PANELS, SWITCHES, MOTORS, WIRING, BREAKER SIZES, AND EQUIPMENT NECESSARY TO ADAPT TO
<br />THE SERVICE AVAILABLE, THE REQUIREMENTS of THE UTILITY COMPANY, LOCAL CODES OR THE SIZE of
<br />HEATING, VENTILATING t AIR CONDITIONING EQUIPMENT SPECIFIED.
<br />32 TELEPHONE INSTALLATION
<br />A.INSTALL CONCEALED TELEPHONE CONDUIT INCLUDING NECESSARY PULL BOXES AND FISH WIRE IN
<br />ACCORDANCE WITH LOCAL TELEPHONE COMPANY REQUIREMENTS TO LOCATIONS INDICATED ON THE DRAWINGS,
<br />WHEN CALLED FOR ON THE SITE DRAWING, ALSO PROVIDE NECESSARY CONDUIT TO OUTSIDE TELEPHONE
<br />BOOTH.
<br />33 INSTALLATION - GENERAL
<br />ACOOPERATE WITH OTHER SECTIONS FOR THE PROPER EXECUTION OF THIS WORK. SUPPLY AND COOPERATE IN
<br />THE PLACEMENT OF INSERTS, SLEEVES AND OTHER EQUIPMENT TO BE INSTALLED IN MASONRY. CAREFULLY CUT
<br />NECESSARY HOLES FOR THE INSTALLATION OF EQUIPMENT AND PATCH IN SUCH A MANNER AS TO MATCH THE
<br />ORIGINAL WORW,
<br />B_MAKE GROUND CONNECTION BETWEEN ALL APPARATUS, SIGNS AND CONDUIT AND THE WATER PIPING AS
<br />REQUIRED BY THE NATIONAL ELECTRICAL CODE AND ACCORDING TO THE REQUIREMENTS OF LOCAL
<br />AUTHORITIES.
<br />3A MUSIC SYSTEM - SPEAKERS
<br />ASEE SECTION 16110,
<br />35 CASH REGISTERS
<br />A.PROVIDE CAT 5E CABLE AND RJ45 TERMINATION POINTS AS INDICATED ON DRAWINGS. PULL WIRE TO EACH
<br />TERMINAL, USING EQUAL LENGTHS OF CABLE FROM MIDDLE OF FRONT COUNTER NETWORK HUB IS LOCATED AT
<br />FRONT LINE (SEE DRAWINGS).
<br />B.PROVIDE ISOLATED SECOND GROUND FOR EACH CASH REGISTER
<br />3.6 TESTS
<br />RAFTER COMPLETE CONNECTIONS AND INSTALLATION OF ALL THE LESSEE'S OR FRANCHISE OWNER'S EQUIPMENT,
<br />TEST ALL WORK AND EQUIPMENT AS REQUIRED BY AUTHORITIES HAVING JURISDICTION, FURNISH ALL EQUIPMENT
<br />NECESSARY, PERSONNEL, AND ELECTRICAL POWER TEST THE ENTIRE INSTALLATION FOR SHORTS, GROUNDS AND
<br />OPEN CIRCUITS, AND CORRECT ALL DEFECTS BEFORE ACCEPTANCE OF THE WORK. ALL WORK SHALL BE
<br />DEMONSTRATED TO BE IN PROPER OPERATING CONDITION TO THE COMPLETE SATISFACTION OF THE FRANCHISE
<br />OWNER INSTRUCT THE OWNER'S REPRESENTATIVES IN THE CARE AND OPERATION OF ALL APPARATUS AND
<br />EQUIPMENT FORMING THE INSTALLATION_
<br />3:1 EMERGENCY LIGHTING
<br />AFURNISH AND INSTALL THE EMERGENCY LIGHTING UNIT AND REMOTE HEADS AS SHOWN, SEE DRAWINGS FOR
<br />LOCATIONS AND TYPE OF EMERGENCY UNITS.
<br />3.8 EXTERIOR AREA LIGHTING
<br />AFURNISH AND INSTALL THE EXTERIOR LIGHTING AS INDICATED BY SYMBOLS ON SITE DRAWING. POLE AND
<br />WEDGE SERIES POLE LIGHTS SHALL BE MANUFACTURED BY VILLA LIGHTING OR SECURITY LIGHTING SYSTEMS,
<br />INC_ (SPECIFY VOLTAGE WHEN ORDERING). sEE ELECTRICAL PLANS FOR BUILDING LIGHTS_
<br />B.FEATURES.
<br />1. POLE - SQUARE STEEL POLE FINISHED WITH WEATHERPROOF RUST PREVENTATIVE PAINT, FOUR (4)
<br />GALVANIZED ANCHOR BOLTS WITH GALVANIZED NUTS AND WASHERS, METAL TEMPLATE, HAND HOLE, AND
<br />DECORATIVE ANCHOR BOLT COVER VERIFY DIMENSIONS CONFORM TO ALL LOCAL CODE REQUIREMENTS
<br />AND RESTRICTIONS BEFORE PLACING ORDER
<br />2. FIXTURE - 400-WATT HIGH-PRESSURE SODIUM OR METAL HALIDE, DARK BRONZE OR BLACK FINISH. A
<br />COMPLETE MILL FINISHED ALUMINUM HOUSING WITH ACCESS TO LAMP AND BALLAST THROUGH HINGED DOOR
<br />ASSEMBLY, ONE-PIECE TEMPERED GLASS LENS AND OPTICAL SYSTEM FABRICATED of POLISHED ALZAK
<br />ALUMINUM. ALSO INCLUDES ADJUSTABLE TENON ADAPTER AND INTEGRAL/ADJUSTABLE LIGHT CUP of
<br />SHIELD_
<br />SECTION .26 16M
<br />DRIVE-THRU WIRELESS COMMUNICATION SYSTEM
<br />PART I GENERAL
<br />iJ WORK INCLUDED
<br />A.FURNISH ALL LABOR AND MATERIAL NECESSARY FOR THE COMPLETE INSTALLATION of THE WIRELESS
<br />DRIVE-THRU COMMUNICATION SYSTEM SHOWN ON THE DRAWINGS, As SPECIFIED IN THIS SECTION AND IN THE
<br />NATIONAL ACCOUNT SOURCE INFORMATION,
<br />PART 2 PRODUCTS
<br />2J MATERIAL / EQUIPMENT
<br />AREFER TO THE NATIONAL ACCOUNT SOURCE INFORMATION FOR ORDERING INFORMATION, PRICES, DETAILED ITEM
<br />DESCRIPTIONS AND MODEL NUMBERS.
<br />PART 3 EXECUTION
<br />3.1 INSTALLATION
<br />A.ALL INSTALLATION IS TO BE PERFORMED BY AN AUTHORIZED INSTALLER
<br />SECTION 26 1100
<br />INTERIOR MUSIC SYSTEM
<br />PART GENERAL
<br />1.1 WORK INCLUDED
<br />AFURNISH ALL LABOR AND MATERIAL NECESSARY FOR THE COMPLETE INSTALLATION of THE INTERIOR MUSIC
<br />SYSTEM AS INDICATED ON THE DRAWINGS AND As SPECIFIED IN THIS SECTION -
<br />PART 2 PRODUCTS
<br />2JCEILINC SPEAKERS AND HARDWARE
<br />ACEILING SPEAKERS AND ALL HARDWARE SHALL BE PROVIDED AND INSTALLED BY AN APPROVED MUSIC
<br />VENDOR, MODEL NUMBERS AS INDICATED ON NATIONAL ACCOUNT SOURCE INFORMATION- INSTALL HARDWARE IN
<br />THE OFFICE. COORDINATE EXACT LOCATION WITH FIELD REPRESENTATIVE.
<br />BALL INTERIOR SPEAKERS TO BE FLUSH MOUNTED, AND WHITE IN COLOR ALL EXTERIOR SPEAKERS ARE TO BE
<br />BLACK IN COLOR
<br />C.FURNISH VOLUME CONTROL DEVICE IN AN AREA DESIGNATED BY THE OWNER, WITH SEPARATE VOLUME
<br />CONTROLS FOR THE SALES AREA SPEAKERS, RESTROOM SPEAKERS AND EXTERIOR SPEAKERS.
<br />PART 3 EXECUTION
<br />3.1 INSTALLATION
<br />A.SPEAKERS AND GRILLES SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND
<br />AS SHOWN ON THE ARCHITECTURAL DRAWINGS. SPEAKERS ARE TO BE LOCATED IN EACH RESTROOM, MINIMUM
<br />OF TWO IN THE SEATING AREA, AT ENTRY TO STORE, AND AT EXTERIOR SEATING AREAS WHERE APPLICABLE.
<br />PROVIDE ONE EXTERIOR SPEAKER ADJACENT TO THE REAR SERVICE DOOR DO NOT PROVIDE SPEAKERS IN
<br />SERVICE AREAS.
<br />GENERAL NOTES:
<br />1. ALL WORK SHALL COMPLY WITH ALL LOCAL AND STATE CODES AND AUTHORITIES HAVING
<br />JURISDICTION,
<br />2. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL REWIRED PERMITS AND ARRANGE ALL
<br />REQUIRED INSPECTIONS.
<br />3. THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER CONTRACTORS AND TRADES.
<br />4. THESE DRAWINGS, AS PREPARED, ARE DIAGRAMMATIC BUT SHALL BE FOLLOWED AS CLOSELY
<br />AS CONSTRUCTION OF THE PROJECT AND THE WORK OF THE TRADES WILL PERMIT. EQUIPMENT
<br />LOCATIONS INDICATED ARE APPROXIMATE. COORDINATE EXACT LOCATIONS AND REQUIRED
<br />CLEARANCES WITH EQUIPMENT SUPPLIER AND ALL TRADES PRIOR TO INSTALLATION,
<br />5. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL THE EQUIPMENT INDICATED WITHIN THESE
<br />DRAWINGS UNLESS OTHERWISE NOTED. VERIFY LOCATION AND DIMENSIONS IN THE FIELD PRIOR
<br />TO FABRICATION AND / OR INSTALLATION.
<br />6. ALL ROOF PENETRATIONS SHALL BE AT THE CONTRACTOR'S EXPENSE. COORDINATE WITH
<br />ou NER's RooFING CONTRACTOR so AS NOT TO VOID ANY EXISTING ROOF WARRANTIES.
<br />-1. THE ENTIRE INSTALLATION SHALL BE GUARANTEED FREE OF DEFECTS AND CONTRACTOR
<br />SHALL REPAIR AND / OR REPLACE ANY DEFECTIVE MATERIALS OR EQUIPMENT AT NO COST
<br />TO THE OWNER FOR A MINIMUM PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE BY
<br />ARCHITECT OR ENGINEER
<br />8, ALL WORK SHALL BE SUBJECT TO THE ACCEPTANCE AND APPROVAL OF THE ARCHITECT AND
<br />OWNER THE ARCHITECT SHALL BE NOTIFIED OF ANY AND ALL DISCREPANCIES BETWEEN
<br />FIELD CONDITIONS AND THE CONTRACT DOCUMENTS BEFORE PROCEEDING WITH THAT PORTION
<br />OF THE WORK. FAILURE OF PROPER NOTIFICATION DOES NOT RELIEVE THE CONTRACTOR THE
<br />CONTRACTOR SHALL CORRECT ANY AND ALL WORK ARISING FROM SUCH FAILURE TO
<br />COORDINATE DISCREPANCIES TO THE SATISFACTION OF THE ARCHITECT WITHOUT ADDITIONAL
<br />COST TO THE OWNER
<br />9. COORDINATE ALL EQUIPMENT UTILITY INFORMATION SHOWN ON THIS SHEET WITH THE DUNKIN'
<br />BRANDS EQUIPMENT SCHEDULE AND EQUIPMENT MANUFACTURER'S CUT sHEETS.
<br />10, ALL EXTERIOR LIGHTS TO BE TIMECLOCK CONTROLLED.
<br />11, ALL 15 AND 20 AMP, 120 VOLT RECEPTACLES IN KITCHEN AND PREP ALAS SHALL BE CFI
<br />TYPE.
<br />12. ALL JUNCTION BOXES SHOWN ON THIS PLAN ARE TO BE INSTALLED ABOVE THE FINISHED
<br />CEILING.
<br />13, ALL EMERGENCY AND EXIT FIXTURES SHALL BE CONNECTED TO LOCAL LIGHTING CIRCUIT
<br />AHEAD OF ANY SWITCHING. PROVIDE ADDITIONAL FIXTURES AS NEEDED TO MEET THE CODE
<br />REQUIREMENTS PER LOCAL REQUIREMENTS.
<br />14. PROVIDE WOOD BLOCKING BEHIND ALL EXTERIOR LIGHTING FIXTURES COORDINATE WITH
<br />GENERAL CONTRACTOR
<br />15. THE CONTRACTOR IS RESPONSIBLE FOR REVIEWING THE LATEST KITCHEN PLANS AND
<br />EQUIPMENT CUTS SHEETS FOR PROPER EQUIPMENT LOCATIONS AND CONNECTION
<br />REQUIREMENTS PRIOR TO STARTING WORK.
<br />16. "NL" DESIGNATION INDICATES FIXTURE TO BE NIGHT LIGHT, CIRCUITED HOT FOR CONTINUOUS
<br />OPERATION,
<br />11. PROVIDE RED ILLUMINATED SWITCH FOR HOOD EXHAUST FAN CONTROL AND LIGHTS. PROVIDE
<br />TAG ABOVE SWITCH IDENTIFYING HOOD USE.
<br />18. SPEAKER AND SOUND SYSTEM TO BE PROVIDED AND INSTALLED BY ELECTRICAL
<br />CONTRACTOR LOCATE VOLUME CONTROL IN THE OFFICE. SEE ARCHITECTURAL CEILING PLAN
<br />FOR EXACT LOCATION AND CONTROL.
<br />THE MUSIC SYSTEM IS A REQUIREMENT OF THE BRAND AND NO LONGER OPTIONAL_ ARCHITECTS TO
<br />UPDATE ARCHITECTURAL DRAWINGS PER GUIDELINES DIRECTLY BELOW.
<br />I. MUSIC SYSTEM 16 REQUIRED IN ALL NEW AND REMODEL STORES. ALL CEILING SPEAKERS TO BE
<br />FLUSH MOUNTED s GYP. BOARD CLG. t ACT CLG. SPEAKERS • OPEN CEILING TO BE MOUNTED
<br />ON LOWER CORD of RooF TRUSSESALL INTERIOR SPEAKERS TO MATCH SURFACE IT IS MOUNTED
<br />ON, ALL EXTERIOR SPEAKERS TO BE BLACK, WITH EXTERIOR GRADE CONSTRUCTION.
<br />2. MUSIC SYSTEM IS REQUIRED IN ALL NEW AND REMODEL STORES. MUSIC SYSTEM TO USE DBI
<br />APPROVED PROGRAMMING
<br />3. ALL CEILING SPEAKERS TO BE FLUSH MOUNTED WHITE. ALL EXTERIOR SPEAKERS TO BE BLACK,
<br />WITH EXTERIOR GRADE CONSTRUCTION.
<br />4. ONE SPEAKER IN EACH BATHROOM TO BE FLUSH MOUNTED WHITE.
<br />S. A MINIMUM OF TWO SPEAKERS IN THE SEATING AREA (NO SPEAKERS IN THE SERVICE AREA).
<br />6. A MINIMUM OF TWO SPEAKERS AT EXTERIOR SEATING AREAS WHERE APPLICABLE.
<br />'1. SPEAKER AT EXTERIOR of BUILDING ADJACENT TO ENTRY.
<br />8. PROVIDE AND INSTALL SEPARATE VOLUME CONTROLS FOR EACH AREA (RESTROOMS, SEATING
<br />AREA, EXTERIOR)
<br />s. HARDWARE TO BE INSTALLED IN THE OFFICE. FIELD VERIFY AND COORDINATE WITH FRANCHISE
<br />FOR THE EXACT LOCATION OF THE UNIT AND VOLUME CONTROLS.
<br />CODE COMPLIANCE INFORMATION
<br />NATIONAL ELECTRICAL CODE- 2011 NATIONAL ELECTRICAL CODE
<br />FLORIDA BUILDING CODE- FBC 2020, SEVENTH EDITION
<br />FLORIDA FIRE PREVENTION CODE - FFPC 2020, SEVENTH EDITION
<br />FLORIDA ENERGY CONSERVATION CODE- FBC 2020 ENERGY CODE,
<br />SEVENTH EDITION
<br />SYMBOL:
<br />LIGHTING
<br />OCIZI 1' x 4' FLUORESCENT FIXTURE.
<br />F-0H FLUORESCENT STRIP LIGHTING FIXTURE.
<br />O CEILING
<br />LIGH TI
<br />NG FIXTURE, SEE LIGHTING FIXTURE SCHEDULE FOR
<br />Q WALL MOUNTED LIGHT FIXTURE.
<br />EXIT LIGHT SINGLE FACE UNIVERSAL MOUNT AS SPECIFIED IN THE
<br />FIXTURE SCHEDULE. LETTER INDICATES IXTURE TYPE. BLACK QUADRANT
<br />INDICATES DIRECTION OF FACE, ARROW(S� INDICATE DIRECTION OF
<br />TRAVEL.
<br />CEILING
<br />CEILING
<br />AS SPECIFIED
<br />CEILING
<br />AS SPECIFIED
<br />CEILING OR WALL
<br />FIXTURE LIGHT
<br />LETTEERIINDICATESFIXTURE TYPE CI BLACK THE
<br />CEILING OR WALL
<br />w INDICATES DIRECTION OF FACE, ARROW(S) INDICATE DIRECTION OF
<br />TRAVEL.
<br />BATTERY OPERATED EMERGENCY LIGHT FIXTURE. 8'-0" AFF
<br />17-1
<br />m COMBINATION EXIT SIGN AND BATTERY OPERATED EMERGENCY LIGHT 8'-0" AFF
<br />Q� FIXTURE.
<br />DW] BATTERY OPERATED EMERGENCY LIGHT FIXTURE, CEILING MOUNTED. CEILING
<br />SINGLE POLE SWITCH. ��// EE 48" AFF
<br />Sb SMALL OLETTER DESIGNCATIO�ASNDIGAOTESRLIGHTINGWZO�E CONSULT MFR 48" AFF
<br />LC LIGHTING CONTACTOR. AS NOTED
<br />POWER
<br />E)=
<br />DUPLEX RECEPTACLE.
<br />18" AFF
<br />DUPLEX RECEPTACLE. IG=ISOLATED GROUND.
<br />18" AFF
<br />DUPLEX RECEPTACLE, MTD 48" AFF OR 6" ABOVE COUNTER BACKSPLASH.
<br />=E)=
<br />DUPLEX RECEPTACLE, MOUNTED IN CEILING.
<br />CEILING
<br />QUADRAPLEX RECEPTACLE (DOUBLE DUPLEX),
<br />MOUNTED IN CEILING..
<br />CEILING
<br />0
<br />QUADRAPLEX (DOUBLE DUPLEX) RECEPTACLE.
<br />18" AFF
<br />QUADRAPLEX (DOUBLE DUPLEX) RECEPTACLE,
<br />MTD. 48" AFF OR 6" ABOVE
<br />COUNTER.
<br />1�):
<br />DUPLEX GROUND FAULT CIRCUIT INTERRUPTED
<br />RECEPTACLE.
<br />18" AFF
<br />�^
<br />DUPLEX GROUN
<br />P FAULT CIRCUIT INTERRUPTED
<br />RECEPTACLE -MOUNTED
<br />48 AFF OR 6 ABOVE COUNTER BACKSPLASH.
<br />SPECIAL PURPOSE OUTLET, NEMA CONFIGURATION AS SHOWN.
<br />18"
<br />AFF
<br />PANELBOARD.
<br />6"-6"
<br />TO TOP
<br />RECESSED FLUSH -MOUNTED PANELBOARD. FRONT OF PANEL INDICATED
<br />6"-6"
<br />TO TOP
<br />BY LONGER EDGES OF SYMBOL.
<br />®
<br />DISTRIBUTION PANELBOARD.
<br />6"-6"
<br />TO TOP,
<br />®
<br />METER SOCKET, PROVIDE PER UTILITY COMPANY REQUIREMENTS.
<br />4'-0" MIN. TO
<br />5-0" MAX.
<br />TC
<br />TIME CLOCK
<br />54"
<br />AFF
<br />SHUNT TRIP PUSH BUTTON.
<br />54"
<br />AFF
<br />EQUIPMENT SYMBOLS (�
<br />ti OOTOR CONNECTION CONNECTION. EQUIPMENT
<br />NSTALLED EQUIPMENT.
<br />C:P SAFETY DISCONNECT SWITCH-30A, 3 , 250V, NF, HD, NEMA 1, U.N.O.
<br />USN MOTOR CONTROLLER
<br />NP COMBINATION MOTOR STARTER & FUSED DISCONNECT SWITCH, U.N.O.
<br />SPECIAL CABINET OR EQUIPMENT AS NOTED, RECESED MOUNTED.
<br />$M MANUAL MOTOR $TARTER WITH OVERLOAD HEATERS FOR 120V, 1
<br />FRACTIONAL HP, MOTORS.
<br />Ce ENCLOSED CIRCUIT BREAKER IN NEMA 1 ENCLOSURE, U.N.O.
<br />T�s DRY TYPE TRANSFORMER (NUMBER INDICATES KVA RATING).
<br />CONDUIT, RACEWAY AND WIRING
<br />HOME
<br />HOMERUNS PANEL, L NUMBER OF HASH MARMINIMU I ATES NUMBER OF CIRCUITS.
<br />---- Ili GROUNDING CONDUCTOR.
<br />Tr WALL MOUNTED GROUND BAR. (24"W X 3"H X 1/4"T U.N.O.).
<br />CONDUIT IN/UNDER SLAB.
<br />-� CONDUIT CAP.
<br />----o DN CONDUIT STUB -DOWN.
<br />-Q uP CONDUIT STUB -UP.
<br />A DETAIL NUMBER.
<br />E-1 ELECTRICAL SHEET NUMBER.
<br />GENERAL NOTES
<br />2.
<br />4.
<br />ALL COI
<br />UN(
<br />5.
<br />ALL CO
<br />UNI(
<br />BOTH E
<br />DS.
<br />6.
<br />ALL CO
<br />DUIT
<br />7.
<br />ALL SY
<br />BOLS
<br />ABBREVIATIONS
<br />A AMPS
<br />AFF ABOw�t Fit\
<br />AHJ AUTHORITN
<br />AHU AIR HANDL
<br />C./CDT. CONDUIT
<br />DRAWINGS)
<br />OF ANOTHER DIVISION SECTION, OR PART OF THE SPECIFICATIONS
<br />OF THIS DIVISION T OSE REQUIREMENTS SHALL GOVERN. ENGINEER
<br />I OF WHICH REQIIIRE�ENT HALL GOVERI��.(
<br />)F PENETRATIONS SHALL MAINTAIN THE E VIRONMENTAL AND FIRE
<br />THE ROOFNGEWARRANTY. PITCHBPEEOCKET RNOOF PENETRATIONS ROOFING
<br />IT SHALL
<br />ALLL BE `IDENTIIF ED DY PAL BE TO CENTER
<br />�DIST BENDS.
<br />NUMBERE OF DEVICE S AND LABELED AT
<br />$RESENTED M Y N0 NECESSARILY 4BE MUSED ON THESE DRAWINGS.
<br />C.B.
<br />CIRCUIT BREAKER
<br />CLG
<br />CEILING
<br />CggU
<br />CONDENSING UNIT
<br />DNC
<br />DR NNNECT
<br />H ETAL HALIDE
<br />OOR T. OUNTING
<br />JURISDICTION CB AIN CIRCUIT BREAKER
<br />�0 AIN LUG ONLY
<br />S NANUANLOTOR STARTER
<br />NNF NoN FUSEELECTRICAL CODE
<br />EC
<br />EL CTRCAL CONTRACTOR
<br />EF
<br />EXHAYgT FAN
<br />E PT
<br />EQUIPMENT
<br />EWC
<br />ELECTRIC WATER COOLER
<br />EWH
<br />ELECTRIC WATER HEATER
<br />GC
<br />GENERAL CONTRACTOR
<br />GFI
<br />GROUND FAULT INTERRUPTER
<br />GNDG. GROUND
<br />HPS
<br />HP
<br />HMC
<br />KC
<br />SODIUM
<br />4TED SWITCH
<br />ETAL CONDUIT
<br />WATER HEATER
<br />RTU ROOF -TOP UNIT
<br />S�y SHUNT TRIP
<br />TTB TEL PH NE TER
<br />TVSS TRA SIE t VOL'
<br />LIGH�NIN� ARRE;
<br />UNO UNLE S NOTED
<br />WATT
<br />W WEATHERPROOF
<br />E T ERPROOF
<br />VOLPHASE
<br />Q DRAWING NOTE
<br />BACKBOARD
<br />SURGE SUPPRESSOR/
<br />(NEMA 3R)
<br />PE 14176
<br />L0'�%SVVE
<br />O•• .� 00660000
<br />GAR-" p PE
<br />FL Lim No.- 14175
<br />L_
<br />O
<br />•-°v_
<br />O
<br />>
<br />C
<br />Z
<br />0
<br />75
<br />N_
<br />Li
<br />_
<br />O
<br />m
<br />•
<br />w
<br />L
<br />-
<br />�
<br />t
<br />C
<br />�
<br />�
<br />C0
<br />m
<br />V
<br />x
<br />N
<br />O
<br />W
<br />L
<br />r
<br />u7
<br />y
<br />0
<br />to
<br />CL
<br />m
<br />c
<br />Date: 07. 26. 22
<br />Scale: AS NOTED
<br />Project Mgr: JDR
<br />Drawn:
<br />Job: 21-202
<br />Sheet
<br />EO
<br />J(DI ELEC"O RICAL a c1FICATIONS � L cTRICAL LEGEND
<br />SCALE. NOT TO SCALE SCALE: NOT TO SCALE
<br />
|