My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6512 Gall Blvd (9)
Zephyrhills
>
Building Department
>
Building Plans
>
6512 Gall Blvd (9)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:39:58 AM
Creation date
2/25/2025 4:13:55 PM
Metadata
Fields
Template:
Building Plans
Street #
6512
Location
Gall Blvd
Contractor
Compass Construction Management LLC
Building Plans - Permit #
4760
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I1 L_ A.�AAllii�ll{WI11UMAWaL,i" <br />d-SWIENERAL NOTES <br />GENEF"L PIROJECT NOTES <br />KEYED NOTES <br />REVISIONS 1 BY <br />1tlELD VERIFY EXACT LOCATIONS <br />r !� K-42 <br />r, IN PC <br />15 15 15 1. <br />1, ALL 15 AND 20 AMP, 125 VOLT RECEPTACLES IN <br />THE KITCHEN AND SERVICE AREA SHALL BE GFCI <br />PROTECTED IN ACCORDANCE WITH NEC 210B(5X2). <br />PROVIDE GFCI RECEPTACLES IN THE KITCHEN AND <br />SERVICE AREA. CONTRACTOR TO PROVIDE GFCI <br />TYPE CIRCUIT BREAKERS FOR THOSE <br />NON -READILY ACCESSIBLE RECEPTACLES IN THE <br />KITCHEN AND SERVICE AREA. 2011 NEC ART. 210.5 <br />2. DEVICE LOCATIONS AND MOUNTING HEIGHTS SHOWN <br />ARE RECOMMENDED BY DUNKIN' DONUTS, <br />HOWEVER FIELD CONDITIONS MAY VARY_ <br />3, COORDINATE THE EXACT LOCATIONS AND <br />MOUNTING HEIGHTS OF RECEPTACLES, VOICE/DATA <br />OUTLETS AND ALL OTHER ELECTRICAL DEVICES <br />WITH THE OWNER PRIOR TO ROUGH- IN. <br />4. ALL DEVICE DIMENSIONS ARE AFF TO C/L UNLESS <br />OTHERWISE <br />5. POS - POINT OF SALES TERMINAL. LABEL <br />RECEPTACLE "POS ONLY". COORDINATE CONDUIT <br />ROUTING AND JUNCTION BOX LOCATIONS FOR POS <br />NETWORK WIRING WITH THE OWNER PRIOR TO <br />ROUGH -IN <br />6_ REFER TO KITCHEN EQUIPMENT SCHEDULE FOR <br />ADDITIONAL INFORMATION. 0 VERIFY ALL <br />EQUIPMENT REQUIREMENTS WITH OWNER PRIOR TO <br />ROUGH- IN <br />7. KITCHEN EQUIPMENT AND REFRIGERATION IS TO BE <br />PROVIDED BY THE OWNER. VERIFY ALL EQUIPMENT <br />PRIOR TO ROUGH -IN. <br />8. NO AS -BUILT OR PANEL SCHEDULE INFORMATION IS <br />AVAILABLE. THE CONTRACTOR SHALL VERIFY <br />CIRCUITS WITHIN THE EXISTING PANELS THAT AREA <br />EXISTING TO REMAIN AND NOTIFY THE ARCHITECT IF <br />ANY CONFLICT ARISES WITH THE NEW EQUIPMENT <br />CIRCUITS PRIOR TO ROUGH -IN <br />9, SEE POS AND COMMUNICATIONS. PLAN FOR <br />FURTHER INFORMATION REGARDING POS AND <br />UNDER COUNTER ELECTRICAL SERVICE. <br />10, ELECTRICAL CONTRACTOR TO PROVIDE 25 FT. <br />PIGTAIL FOR DONUT CASE WIRING. <br />11, PROVIDE JUNCTION BOXES AT TOILETS, SINKS AND <br />OPTIONAL URINAL IF ALTERNATE "HANDS FREE" <br />TOILET FIXTURES ARE BEING PROVIDED <br />12. REFER TO POS COMMUNICATIONS FLOOR PLAN FOR <br />LOCATIONS AND ELEVATIONS OF OFFICE <br />RECEPTACLES. <br />13. CONNECT THE DRIVE THRU MENU BOARD LIGHTING <br />AND DT CANOPY LIGHTING CIRCUITS TO THE <br />TIMECLOCK. <br />14, ELECTRICAL PANELS SHALL BE RECESSED WITH <br />FLUSH PANEL COVERS. <br />15, CONTRACTOR TO MOUNT RECEPTACLE IN THE <br />CEILING BEHIND THE MENUBOARD. VERIFY ACTUAL <br />LOCATION WITH ARCHITECT PRIOR TO INSTALLING. <br />16, COORDINATE ALL EQUIPMENT UTILITY INFORMATION <br />SHOWN ON THIS SHEET WITH THE DUNKIN' BRANDS <br />EQUIPMENT SCHEDULE AND EQUIPMENT <br />MANUFACTURER'S CUT SHEETS. <br />GENERAL PROJECT NOTES: <br />1, BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE <br />THEMSELVES WITH EXISTING CONDITIONS AND SATISFY <br />THEMSELVES AS TO THE NATURE AND SCOPE OF WORK <br />THE SUBMISSION OF A BID WILL BE EVIDENCED THAT <br />SUCH AN EXAMINATION HAS BEEN MADE. LATER <br />CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS <br />REQUIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH <br />COULD HAVE BEEN FORESEEN HAD AN EXAMINATION <br />BEEN MADE, WILL NOT BE ALLOWED. <br />2. COORDINATE WITH OTHER TRADES FOR ITEMS IN THEIR <br />SCOPE OF WORK WHICH WOULD REQUIRE ELECTRICAL <br />WORK (DISCONNECTION/RECONNECTION ETC.) AND ARE <br />NOT INDICATED ON THE ELECTRICAL PLANS. <br />RECEPTACLES TAGGED WITH "USB" IN THE SALES 4 <br />SEATING AREAS SHALL BE <br />HUBBELL OUS515X2W (WHITE) / NP26W (WHITE) <br />COMBO USB CHARGER WITH TAMPER -RESISTANT <br />RECEPTACLE. <br />SEATING AREA RECEPTACLES SHALL BE WHITE <br />WITH WHITE COVER PLATE AND ARE TO BE <br />MOUNTED AT 18" AFF. <br />COORDINATE RECEPTACLE COLOR WITH <br />ARCHITECT PRIOR TO ORDERING. <br />CARBON MONOXIDE MONITORING: <br />CONTRACTOR SHALL PROVIDE CARBON <br />MONOXIDE MONITORING AND ALARMING THE <br />OCCUPANTS UPON THE PRESENCE OF CARBON <br />MONOXIDE (CO). THE MEANS OF DETECTION SHALL <br />BE LOCATED NEAR EQUIPMENT THAT PRODUCES <br />PRODUCT OF COMBUSTION. LOCATIONS SHALL <br />INCLUDE BUT NOT BE LIMITED TO GAS FIRED <br />OVENS, GAS FIRED WATER HEATERS, GAS FIRED <br />FURNACES, ETC. <br />NOTE <br />ELECTRICAL OUTLETS LOCATED IN SALES AREA <br />TO BE 18" ABOVE FINISHED FLOOR <br />GENERAL NOTES: <br />BRACH CIRCUIT NUMBERS ARE SHOWN FOR DESIGN <br />INTENT. THE CONTRACTOR MAY REUSE EXISTING <br />BRANCH CIRCUITS AND INDICATE ACTUAL BRANCH <br />CIRCUITS USED ON THE AS BUILT PLANS. <br />DRAWINGS NOTES : U <br />I. EXTEND A 2" CONDUIT OR AS DIRECTED BY OWNER ANC <br />SYSTEM INSTALLERS WITH PULLWIRE TO THE TELEPHONE <br />TERMINAL BOARD FOR TELEPHONE AND INTERNET <br />SERVICES. COORDINATE EXACT LOCATIONS AND <br />REQUIREMENTS WITH SERVICE PROVIDERS AND OWNER. <br />PROVIDE A 04 CUI GROUND TO BLDG GEC. <br />2, COORDINATE EXACT NUMBER AND LOCATIONS FOR <br />OFFICE RECEPTACLES AND TELEPHONE/DATA OUTLETS <br />WITH OWNER PRIOR TO ROUGH -IN. SEE LOW VOLTAGE <br />SHEETS FOR FURTHER INFORMATION REGARDING <br />ELECTRIC SERVICE TO OFFICE. <br />3. 3/4"THICK X 4'WIDE TELEPHONE TERMINAL BOARD <br />PAINT WITH FIDE RETARDANT PAINT TO MATCH WALL. <br />PROVIDE A GROUND BAR AT THE TELEPHONE BOARD. <br />4. PROVIDE FINAL CONNECTION TO DRIVE THRU <br />SYSTEM/WINDOW. COORDINATE WITH GENERAL <br />CONTRACTOR <br />5. COORDINATE RECEPTACLE AND DATA OUTLET <br />LOCATION FOR DRIVE THRU WITH G.0 AND OWNER PRIOR <br />TO ROUGH -IN. <br />6_ PROVIDE FINAL CONNECTION TO DRIVE THRU MENU <br />BOARD. COORDINATE CONTROL OF LIGHTING IN MENU <br />BOARD WITH OWNER. PROVIDE AN EXTRA SWITCHED <br />CONDUCTOR ROUTED VIA LIGHT SWITCH OR THE <br />LIGHTING CONTACTOR AS DIRECTED BY THE OWNER. <br />1. MARCH SYSTEM VIDEO SURVEILLANCE SYSTEM VERIFY <br />LOCATION WITH OWNER. <br />8. PROVIDE FINAL CONNECTION TO DRIVE THRU ORDER <br />CANOPY/DISPLAY SYSTEM AND SPEAKER TOWER. <br />9. PROVIDE A RECEPTACLE FOR THE NETWORK HUB. FIELD <br />VERIFY EXACT LOCATION. <br />10, EXISTING ELECTRICAL PANEL TO REMAIN. REFER TO <br />RISER DIAGRAM AND PANEL SCHEDULE ON SHEET E6 <br />FOR REQUIREMENTS. <br />11, PROVIDE A RECEPTACLE FOR A HEADSET <br />TRANSMITTER. COORDINATE EXACT LOCATION WITH <br />OWNER. <br />12, PROVIDE A RECEPTACLE FOR THE BOOSTER PUMP, <br />COORDINATE FINAL LOCATION AND REQUIREMENTS WITH <br />PLUMBING CONTRACTOR, <br />13, PROVIDE A HP RATED DISCONNECT AND FINAL <br />CONNECTION TO AIR DOOR COORDINATE EXACT <br />LOCATION WITH AIR DOOR INSTALLER <br />14. ELECTRICAL WORK IN THIS AREA IS EXISTING TO <br />REMAIN UNLESS NOTED OTHERWISE, <br />15, PROVIDE FINAL CONNECTION TO DRIVE THRU LOOP <br />SYSTEM. COORDINATE EXACT LOCATION AND FINAL <br />REQUIREMENTS WITH G.0 AND SYSTEM INSTALLER <br />16. PROVIDE A RECEPTACLE FOR KIOSK. COORDINATE <br />EXACT LOCATION AND REQUIREMENTS WITH KIOSK <br />INSTALLER AND OWNER <br />11. CONTRACTOR SHALL PROVIDE POWER AND <br />NECESSARY WIRING FOR THE HOOD CONTROL PANEL. <br />SEE THE CAPTIVE AIRE DRAWINGS FOR WIRING <br />REQUIREMENTS. COORDINATE FINAL LOCATION AND <br />REQUIREMENTS WITH MECHANICAL CONTRACTOR AND <br />OWNER <br />•• <br />PE 1411 <br />S1�dE <br />GAPo&P�TT ' PE <br />L. <br />O <br />y <br />C <br />O <br />-v <br />v <br />> <br />o <br />0 <br />c <br />Z <br />m <br />y <br />Li <br />m <br />i <br />w <br />t <br />Z <br />= <br />s <br />0 <br />'� <br />o <br />0 <br />a <br />m <br />o <br />U <br />} <br />x <br />C <br />N <br />N <br />0 <br />W <br />0 <br />LC) <br />y <br />O <br />t0 <br />a. <br />m <br />C <br />Date: 07. 26. 22 <br />Scale: AS NOTED <br />Project Mgr: JDR <br />Drawn: <br />Job: 21-202 <br />�I ELECTRICAL POWER PLAN <br />SCALE: 3/16"■ P-0" <br />Sheet <br />E2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.