S.S. SINK BY G.C.
<br />HOLE FIELD CUT
<br />INSTALLED BY G.(
<br />FINAL CONNECTI(
<br />c
<br />Al Oil
<br />PAINT P-1
<br />SPLASH
<br />F TO WALL KOROGARD WALL 2'43Y4"
<br />COVERING -_ Ak
<br />)F
<br />UPPER
<br />CABINETS
<br />PLASTIC LAMINATE WALL
<br />01 2'-0"
<br />ol 2'-6" P11L.
<br />CABINET TOP, SPLASH AND
<br />BASE
<br />ONE ADJUSTABLE SHELF
<br />-
<br />-
<br />DOOR FRONT -SOLID BACK----.
<br />ACK
<br />/
<br />\
<br />GFCI OUTLET
<br />COFFEE MAKER BY ROSS
<br />- -
<br />- -
<br />T
<br />N
<br />N
<br />KOROGARD TO GO BEHIND
<br />1'-6"
<br />BACK SPLASH
<br />L
<br />_J
<br />4" SPLASH ALONG 0
<br />o
<br />n
<br />_
<br />REAR +4 1/2" WALL 0
<br />L
<br />co
<br />PANEL OF BASE O
<br />r
<br />CABINET, SCRIBE TO
<br />_
<br />WALL AND CAULK
<br />4'-0" WALL PANELV-07
<br />TRIM TO CABINET o
<br />Y
<br />MICROWAVE BY ROSS
<br />cv
<br />r
<br />_z
<br />rn
<br />(OPENING 17 1/2" x 27")
<br />-0
<br />GFCI OUTLET
<br />O
<br />I I
<br />4" STAINLESS STEEL
<br />WIRE PULLS - TYP
<br />WALL
<br />MOUNTED
<br />2 EQUAL DRAWER
<br />2' 6" MIN
<br />TOWEL
<br />DISPENSER
<br />4"H X 2"D TOESPACE WITH 4"
<br />BY BOSS
<br />RUBBER BASE, CONTINUOUS
<br />WALL MOUNTED
<br />AT BOTTOM OF COUNTER
<br />SOAP DISPENSER
<br />ACCESSIBLE KNEE & FLOOR
<br />BY ROSS
<br />CLEARANCE OPEN FRONT -SOLID
<br />BACK PROVIDE PIPE PROTECTION
<br />ELEVATION
<br />NOTES:
<br />1. 3 PAIR PIVOT HINGES PER DOOR
<br />2. ALL PANEL CORES TO BE 3/4" PARTICLE BOARD OR EQUAL
<br />3. FIXTURES SHALL CONFORM TO ARCHITECTURAL WOODWORK INSTITUTE OR
<br />WOODWORK INSTITUTE OF CALIFORNIA: "CUSTOM" GRADE STANDARDS.
<br />4. FINISH TO BE PLASTIC LAMINATE AT ALL EXPOSED SURFACES, INCLUDING BASE.
<br />FINISH TO BE PAINT AT ALL SEMI -EXPOSED SURFACES
<br />5. PLASTIC LAMINATE TO BE WILSONART D315-60 "PLATINUM"
<br />6. PAINT TO MATCH PLASTIC LAMINATE, SEMI -GLOSS.
<br />7. MICROWAVE DUPLEX TO BE INSTALLED W/ EXTENSION AND W/ DEVICE AND COVER
<br />PLATE FLUSHED AT FINISHED BACK OF CABINET - SEE ELECT. DWGS.
<br />8. COUNTER AND SINK TO BE COMPLETE AND FUNCTIONING IN EVERY ASPECT AND
<br />DETAIL AT TIME OF CONSTRUCTION TURNOVER, NO EXCEPTION.
<br />9. SEE PLAN TO CONFIRM IF COUNTER IS TO BE RIGHT OR LEFT JUSTIFIED (RIGHT
<br />JUSTIFIED SHOWN HERE). LEFT JUSTIFIED IS MIRROR OF THAT SHOWN HERE.
<br />? M
<br />N
<br />H.C. ACCESSIBLE 6" COVE BASE
<br />DRINKING FOUNTAINS
<br />INTERIOR ELEV.
<br />SCALE
<br />AT DRINKING FOUNTAINS
<br />1/4"=V-0"
<br />CENTERLINE OF UPPER ROW MOUNTING HOLES
<br />IN BACK WALL OF UNIT. VERIFY THAT THIS
<br />MOUNTING HEIGHT WILL GIVE A +34" BED
<br />HEIGHT WHEN UNIT IS INSTALLED. SEE
<br />MANUFACTURER'S INSTALLATION INSTRUCTIONS
<br />FOR ADDITIONAL INFORMATION
<br />20 GA. METAL STUDS
<br />2"X6" WOOD BLOCKING
<br />ATTACHED TO METAL
<br />STUDS Wi 3" DRYWALL
<br />311
<br />SCREWS. MOUNT
<br />BLOCKING FLUSH WITH
<br />FACE OF STUD.
<br />IN
<br />co
<br />(0
<br />16" ROUGH
<br />OPENING
<br />CENTERLINE OF
<br />CHANGING STATION
<br />LOCKER ROOM COUNTER SCALE 8
<br />1 /2" = 1' - OII
<br />FULL HEIGHT FRP, TYPICAL
<br />ALL WALLS - NOTCH METAL
<br />EDGE TRIM AT ALL
<br />RESTROOM ACCESSORIES
<br />5/8" EXTERIOR TYPE A-C
<br />PLYWOOD UNDER FRP, TYF
<br />LAV DEPTH
<br />I
<br />B
<br />A
<br />G
<br />12" 24"
<br />11 G
<br />MIN
<br />I
<br />G
<br />CV 1�
<br />Z
<br />6" COVE BASE
<br />TYP
<br />ELEVATION 'A'
<br />ELEVATION 'A'
<br />L HEIGHT FRP, TYPICAL
<br />WALLS - NOTCH METAL
<br />iE TRIM AT ALL
<br />;TROOM ACCESSORIES -
<br />EXTERIOR TYPE A-C
<br />WOOD UNDER FRP, TYP.
<br />DETAIL SCALE 6
<br />DIAPER CHANGING STATION 1/4"=V-0"
<br />ELECTRIC
<br />ER
<br />VB CEILING
<br />✓. 12'-0" AFF
<br />METAL STRAP,
<br />AROUND
<br />ER AND
<br />VALL
<br />PAN
<br />ESISTANT
<br />f FACE AND
<br />PAINTED,
<br />ATCH WALL.
<br />UM 6-0" SPAN,
<br />BADE WOOD,
<br />PAINTED.
<br />SHELF
<br />K
<br />DETAIL SCALE
<br />WATER HEATER SHELF 1-1/2" = 1' - 0"
<br />ELEVATION '6'
<br />m,
<br />PLUMBING FIXTURES AND ACCESSORIES
<br />NOTE:
<br />UNLESS OTHERWISE NOTED, ALL TOILET ROOM ACCESSORIES ARE BY BOBRICK. GENERAL CONTRACTOR SHALL
<br />PROVIDE AND INSTALL ALL TOILET ACCESSORIES AS NOTED.
<br />ITEM
<br />DESCRIPTION
<br />MANUFACTURER'S ITEM NUMBER
<br />OSURFACE
<br />MOUNTED TOILET SEAT COVER DISPENSER
<br />B-221
<br />40" MAX. A.F.F. TO HIGHEST OPERABLE PART
<br />B
<br />SURFACE MOUNTED SOAP DISPENSER
<br />PROVIDED AND INSTALLED BY
<br />40" MAX. A.F.F. TO HIGHEST OPERABLE PART
<br />ROSS STORES
<br />MOUNTED TOILET TISSUE DISPENSER, 12" MAX. FROM FRONT EDGE OF
<br />B-2892 JUMBO
<br />OSURFACE
<br />TOILET SEAT AND 19" MIN. A.F.F. FROM THE BOTTOM
<br />D
<br />SURFACE MOUNTED SANITARY NAPKIN DISPOSAL, 40" MAX. A.F.F. TO HIGHEST
<br />B-270
<br />OPERABLE PART (WOMEN'S TOILET ROOM ONLY)
<br />OE
<br />S.S. GRAB BARS WITH CONCEALED MOUNTING, SIDE BAR TO BE 42" MIN. LONG
<br />WITH THE FRONT END TO EXTEND 24" BEYOND FRONT EDGE OF TOILET SEAT, BACK
<br />B-6806 W/
<br />2562 ANCHOR PLATES
<br />BAR TO BE 36" MIN. LONG. SEE ADA-1 FOR MOUNTING HEIGHTS.
<br />OF
<br />MIRROR W/ S.S. FRAME, 18"x36"; BOTTOM EDGE OF REFLECTIVE SURFACE @ 40"
<br />MAX. A.F,F.; CLEAR CAULK MIRROR TO FRP WALL; (MIRRORS ARE PROVIDED IN THE
<br />SENTRY MODEL SMS1836 WITH
<br />5 REPLACEMENT ANTI GRAFFITI
<br />WOMEN'S TOILET ROOM ONLY; NO MIRROR IN THE MEN'S TOILET ROOM.)
<br />PLEXI-SHIELDS
<br />GO
<br />HAND DRYER, SEMI -RECESSED, 40" MAX. A.F.F. TO PROJECTION
<br />AMERICAN DRYER EXTREMEAIR
<br />EXT7-M (STEEL WHITE) WITH
<br />ADA-W RECESS KIT
<br />OTIME
<br />MIST DISPENSER - MOUNTED @ T-6" A.F.F.
<br />MS0260
<br />(SOURCE: BUNZL RETAIL, SEE SHEET T001 FOR CONTACT INFO.)
<br />TOILET ROOM PARTITIONS:
<br />BOBRICK, DURALINE SERIES
<br />ACCESSIBLE STALL DOOR TO BE EQUIPPED WITH AUTOMATIC -CLOSING DEVICE, A
<br />1082.67 OVERHEAD BRACED,
<br />OI
<br />CLEAR OPENING WIDTH OF 34" WITH THE DOOR POSITIONED AT 90° FROM ITS
<br />CLOSED POSITION, AND THE INSIDE AND OUTSIDE OF THE DOOR IS TO BE
<br />INSTITUTIONAL HARDWARE
<br />COLOR: P-500 "BLACK STAR"
<br />EQUIPPED WITH A LOOP OR U-SHAPED HANDLE IMMEDIATELY BELOW THE LATCH,
<br />DOOR STOPS AT ALL
<br />THE LATCH HARDWARE SHALL NOT REQUIRE THE USER TO GRASP OR TWIST IN
<br />PARTITION DOORS
<br />ORDER TO OPERATE
<br />JO
<br />DIAPER CHANGING STATION
<br />WHEN OPEN TOP OF TABLE TO BE 34" MAX. A.F.F.
<br />BCS-2
<br />(SOURCE: GAMCO, SEE SHEET T001 FOR CONTACT INFO.)
<br />ACCESSIBLE WATER CLOSET: KOHLER HIGHCREST TOILET K-4302 (1.6 GPF) WITH K 4670 C SEAT AND SLOAN ROYAL
<br />1 A
<br />110 EXPOSED FLUSH VALVE (3.5 GPF) WITH VACUUM BREAKER AND STOP. MAXIMUM 5-POUND-FORCE REQ'D FOR
<br />ACTIVATION. SEE ADA-1 FOR MOUNTING HEIGHTS.
<br />WATER CLOSET: KOHLER WELCOMME K-4350 (1.6 GPF) WITH K-4670-C SEAT AND SLOAN ROYAL 110 EXPOSED FLUSH
<br />1 B
<br />VALVE (3.5 GPF) WITH VACUUM BREAKER AND STOP.
<br />RESTROOM LAVATORY: AMERICAN STANDARD, LUCERNE 0355.012 WHITE, WITH HERITAGE CENTERSET FAUCET
<br />5402.172V.002 WITH WRIST HANDLES. FAUCET CONTROLS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT
<br />TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST WITH A MAXIMUM 5-POUND-FORCE REQ'D FOR
<br />OREQUIRE
<br />ACTIVATION. SEE ADA-1 FOR MOUNTING HEIGHTS. HOT WATER AND DRAIN PIPES UNDER ALL LAVATORIES SHALL BE
<br />INSULATED WITH TRUEBRO LAVGUARD DEVICE OR APPROVED EQUAL (PIPE WRAP IS NOT ALLOWED); THERE SHALL BE
<br />NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES
<br />Illy
<br />KOHLER, BARDON HIGH EFFICIENCY K-4904-ET WHITE. RIM TO PROJECT 14" MIN. AND 19" MAX. FROM WALL
<br />AND
<br />AND 17" MAX. A.F.F.
<br />4
<br />JANITOR CLOSET SERVICE SINK: FLORESTONE MODEL #91 36"X 24"X 12" WITH STAINLESS STEEL CAP. FAUCET:
<br />CENTRAL BRASS #0054-YELSRC-Q SERVICE SINK FAUCET.
<br />ODRINKING
<br />FOUNTAIN: HALSEY-TAYLOR BARRIER -FREE HACBLSS-LR NEW NON REFRIGERATED WATER COOLER TWIN,
<br />NO SUBSTITUTION - SEE ADA-1 FOR MOUNTING HEIGHTS. CONTACT FERGUSON CORP. SALES -(757) 939-2639
<br />6
<br />ELECTRIC 4 KW / 10 QUICK RECOVERY GALLON WATER HEATER. HOT WATER HEATER MUST NOT EXCEED 60 FEET
<br />FROM HEATER TO TAP. ALL HOTWATER LINES MUST BE INSULATED. SEE 5/A401 FOR WATER HEATER SHELF.
<br />CONFIRM THAT SIZE MATCHES OR EXCEEDS CODE MINIMUM.
<br />LOCKER ROOM SINK - ELKAY GECR2521 STAINLESS STEEL SINK W/ UNDERSEAL; AMERICAN STANDARD, HERITAGE
<br />FAUCET W/ WRIST BLADE HANDLES. FAUCET CONTROLS SHALL BE OPERABLE WITH ONE HAND AND
<br />O7400.172H.002
<br />7
<br />SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST WITH A MAXIMUM 5-POUND-FORCE
<br />REQ'D FOR ACTIVATION. SEE ADA-1 FOR MOUNTING HEIGHTS. HOT WATER AND DRAIN PIPES UNDER THE COUNTER
<br />SHALL BE INSULATED OR OTHERWISE COVERED, THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER THE
<br />CABINET
<br />8
<br />MARBLE THRESHOLD, DAL -TILE CARRERA.
<br />TOILET ROOM NOTES
<br />1.
<br />GRAB BARS TO BE 1 1/2" DIAMETER, 1 1/2" CLEAR FROM WALL, BOBRICK #B-6806.
<br />2.
<br />ALL OPERABLE FIXTURE COMPONENTS OR LEVERS TO BE MOUNTED 40" MAX. ABOVE FINISH FLOOR
<br />3.
<br />HOT WATER, COLD WATER AND DRAIN PIPES UNDER LAVATORIES TO BE THERMALLY INSULATED
<br />4.
<br />HANDICAP TOILET TO HAVE TOP OF SEAT BETWEEN 17" & 19" A.F.F. OR AS REQ'D BY LOCAL CODES.
<br />5.
<br />TOILET COMPARTMENT DOORS TO BE SELF -CLOSING
<br />6.
<br />PROVIDE FLOOR DRAINS IN TOILET ROOMS AND JANITORS CLOSET. G.C. TO SLOPE NEW CONCRETE OR FLOAT TILE
<br />AS REQUIRED FOR PROPER DRAINAGE. DEMO/TRENCH EXIST. SLAB AS REQ'D. DO NOT LOCATE TOILET PARTITIONS
<br />OVER FLOOR DRAINS.
<br />7.
<br />PROVIDE EXHAUST FAN AT LOCKER ROOM, RESTROOMS, JANITOR'S AND EQUIPMENT CLOSET. FAN TO BE A
<br />T-STAT-CONTROLLED (24/7) DEVICE - SEE MECHANICAL DRAWINGS.
<br />8.
<br />INSTALL ROSS PROVIDED SIGNAGE IN CONFORMANCE WITH LOCAL CODES AND ADA REQUIREMENTS. COORDINATE
<br />WITH ROSS CONSTRUCTION MANAGER. (G.C. TO PROVIDE TEMP. ADA SIGNS UNTIL ROSS'S PROTOTYPICAL SIGNS
<br />ARE PROVIDED)
<br />9.
<br />CONTRACTOR MUST PROVIDE SOLID IN WALL BLOCKING FOR ALL TOILET ROOM ACCESSORIES AND PARTITIONS.
<br />10.
<br />PROVIDE & INSTALL ALL TOILET ROOM SIGNS REQ'D BY LOCAL, STATE & FEDERAL LAWS, INCLUDING ADA. SIGNS
<br />MUST COMPLY WITH SIZE, TEXT, BRAILLE, GRAPHIC STANDARDS AND BE LOCATED IN COMPLIANCE W1 APPLICABLE
<br />REGULATIONS.
<br />6/A401
<br />ELEVATION 'C'
<br />NOTES I SCALE
<br />PLUMBING FIXTURES & ACCESSORIES NONE
<br />FULL HEIGHT FRP, TYPICAL
<br />ALL WALLS - NOTCH METAL
<br />EDGE TRIM AT ALL
<br />RESTROOM ACCESSORIES
<br />5/8" EXTERIOR TYPE A-C
<br />PLYWOOD UNDER FRP, TYF
<br />17" MIN
<br />LAV DEPTH
<br />`6" COVE BASE
<br />ELEVATION 'D'
<br />MEN'S ROOM ELEVATION SCALE
<br />1 /4" = V-0"
<br />FULL HEIGHT FRP, TYPICAL
<br />ALL WALLS - NOTCH METAL
<br />EDGE TRIM AT ALL
<br />RESTROOM ACCESSORIES-
<br />5/8" EXTERIOR TYPE A-C
<br />PLYWOOD UNDER FRP, TYP.
<br />I F I I
<br />J A H A
<br />54" MIN B \ B E
<br />2" 42" \ 24" 12"
<br />MIN. MIN
<br />c� co C \
<br />N 111I-P r% i . 1% 1 1 - -5 (+ D (+
<br />)y C 6" COVE BASE D C 6" COVE BASE SEE DETAIL �L 6" COVE LASE
<br />6/A401 6" 18' 6"-1
<br />TYP TYF
<br />ELEVATION 'B' ELEVATION 'C' ELEVATION 'D'
<br />ACCESSIBILITY NOTES:
<br />1. (1)FITTING ROOM SHALL BE PROVIDED FOR MALE AND
<br />FEMALE CUSTOMERS.
<br />2. ENTRY DOORS SHALL PROVIDE:
<br />a) >t 32" CLEARANCE
<br />b) >_ 18" STRIKE EDGE
<br />3. A MIN. 24"x 48" BENCH SHALL BE PROVIDED BY ROSS:
<br />a) FIXED ALONG LONG SIDE
<br />b) MOUNTED >_ 17" BUT NOT LESS THAN 9".
<br />NOTE:
<br />REFER TO SHEET ADA-1 FOR
<br />DETAILED FITTING ROOM REQ.
<br />NOTE:
<br />A TENANT SPECIFIED FIXTURE VENDOR
<br />AND INSTALLATION CONTRACTOR WILL
<br />PROVIDE AND INSTALL FITTING ROOM
<br />PARTITIONS, HARDWARE, AND
<br />ACCESSORIES (MIRRORS, GRAB BARS,
<br />ETC.) CONTACT TENANT FOR THE NAME
<br />OF THE INSTALLING CONTRACTOR AND
<br />TO COORDINATE AND SCHEDULE THE
<br />WORK WITH THE INSTALLER
<br />NOTE:
<br />ALL DIMENSIONS ARE FROM
<br />FINISH FACE OF WALLS. HOLD
<br />DIMENSIONS ARE CRITICAL
<br />AND SHALL BE MAINTAINED.
<br />HOLD=CLEAR.
<br />PROVIDE RESTROOM
<br />IDENTIFICATION SIGNAGE.
<br />SEE DOOR & HARDWARE
<br />NOTE #22 ON A601. TYP.
<br />NO SUBSTITUTIONS WILL BE
<br />ACCEPTED
<br />WALL DIMENSIONS IN THE
<br />FITTING ROOMS ARE CRITICAL.
<br />FAILURE TO MAINTAIN THE
<br />DIMENSIONS GIVEN IN THE
<br />ARCHITECTURAL PLAN MAY
<br />RESULT IN REJECTION OF THE
<br />WORK.
<br />NOTE:
<br />ANY DEVICE THAT WOULD BE
<br />OPERABLE IN A COMMON OR
<br />PUBLIC SPACE SHALL BE AT
<br />ACCESSIBLE REACH RANGES
<br />(TO THE HIGHEST OPERATING
<br />PART OF DEVICE) AT 48" MAX
<br />AND 15" MIN, TYP.
<br />NOTE:
<br />PROVIDE CONTINUOUS MARBLE
<br />THRESHOLD @ TRANSITION
<br />FROM VCT TO CERAMIC TILE -
<br />COLOR TO MATCH CERAMIC
<br />TILE, TYP. @ RMS 114, 115, 116.
<br />LEGEND
<br />L CORNER GUARD - (CG-1 OR CG-2) SEE 3/A202
<br />FOR MORE FINISH LEGEND INFORMATION
<br />INDICATES 4'-0" H PANELS
<br />INDICATES 6-0" H PANELS
<br />PAINT P-1 ABOVE PANELS U.N.O. ON PLAN.
<br />NOTE: G.C. TO VERIFY EXACT LOCATIONS OF RIGID WALL
<br />COVERING WITH ROSS C.P.M. - SEE DETAIL 8/A501
<br />NOTE:
<br />REFER TO SHEET A501 FOR
<br />WALL PARTITION TYPES.
<br />E
<br />E: G.C. TO VERIFY EXACT
<br />ATIONS OF RIGID WALL
<br />ERING WITH BOSS C.P.M.
<br />N
<br />WOMEN'S ROOM ELEVATION SCALE ENLARGED OFFICE GROUP PLAN SCALE
<br />i 1/111-11 N1 1 1 /^II - it nll
<br />mcg architecture
<br />TT 216.520,1551 FT 216.520.1567
<br />7100 E. Pleasant Valley Rd., Suite 320, Cleveland, OH 44131
<br />Seal:
<br />A Project for:
<br />Client:
<br />ROSS STORES, INC.
<br />4440 ROSEWOOD DRIVE
<br />PLEASANTON, CA 94588
<br />Revisions:
<br />AB ADDENDUM B
<br />04-12-13
<br />BID/PERMIT
<br />02-14-13
<br />No. Description
<br />Project No.:
<br />Date
<br />11.594.01
<br />Drawn By:
<br />LMS
<br />Reviewed By:
<br />BCB
<br />Scale:
<br />NOTED
<br />Date:
<br />01-28-2013
<br />Filename: 11 594A401
<br />Sheet Title:
<br />ENLARGED PLANS,
<br />INTERIOR ELEVATIONS
<br />AND DETAILS
<br />Sheet #:
<br />A401
<br />@ MCG ARCHITECTS 2011 ALL RIGHTS RESERVED
<br />- - - --
<br />I i
<br />i .. - Fl SII-lI Ili �(�il��l�l ��r,„'. bi n.�f� .I �-1I71--J-i_-- _.___.. ..I. _--TT- I
<br />
|