Laserfiche WebLink
S.S. SINK BY G.C. <br />HOLE FIELD CUT <br />INSTALLED BY G.( <br />FINAL CONNECTI( <br />c <br />Al Oil <br />PAINT P-1 <br />SPLASH <br />F TO WALL KOROGARD WALL 2'43Y4" <br />COVERING -_ Ak <br />)F <br />UPPER <br />CABINETS <br />PLASTIC LAMINATE WALL <br />01 2'-0" <br />ol 2'-6" P11L. <br />CABINET TOP, SPLASH AND <br />BASE <br />ONE ADJUSTABLE SHELF <br />- <br />- <br />DOOR FRONT -SOLID BACK----. <br />ACK <br />/ <br />\ <br />GFCI OUTLET <br />COFFEE MAKER BY ROSS <br />- - <br />- - <br />T <br />N <br />N <br />KOROGARD TO GO BEHIND <br />1'-6" <br />BACK SPLASH <br />L <br />_J <br />4" SPLASH ALONG 0 <br />o <br />n <br />_ <br />REAR +4 1/2" WALL 0 <br />L <br />co <br />PANEL OF BASE O <br />r <br />CABINET, SCRIBE TO <br />_ <br />WALL AND CAULK <br />4'-0" WALL PANELV-07 <br />TRIM TO CABINET o <br />Y <br />MICROWAVE BY ROSS <br />cv <br />r <br />_z <br />rn <br />(OPENING 17 1/2" x 27") <br />-0 <br />GFCI OUTLET <br />O <br />I I <br />4" STAINLESS STEEL <br />WIRE PULLS - TYP <br />WALL <br />MOUNTED <br />2 EQUAL DRAWER <br />2' 6" MIN <br />TOWEL <br />DISPENSER <br />4"H X 2"D TOESPACE WITH 4" <br />BY BOSS <br />RUBBER BASE, CONTINUOUS <br />WALL MOUNTED <br />AT BOTTOM OF COUNTER <br />SOAP DISPENSER <br />ACCESSIBLE KNEE & FLOOR <br />BY ROSS <br />CLEARANCE OPEN FRONT -SOLID <br />BACK PROVIDE PIPE PROTECTION <br />ELEVATION <br />NOTES: <br />1. 3 PAIR PIVOT HINGES PER DOOR <br />2. ALL PANEL CORES TO BE 3/4" PARTICLE BOARD OR EQUAL <br />3. FIXTURES SHALL CONFORM TO ARCHITECTURAL WOODWORK INSTITUTE OR <br />WOODWORK INSTITUTE OF CALIFORNIA: "CUSTOM" GRADE STANDARDS. <br />4. FINISH TO BE PLASTIC LAMINATE AT ALL EXPOSED SURFACES, INCLUDING BASE. <br />FINISH TO BE PAINT AT ALL SEMI -EXPOSED SURFACES <br />5. PLASTIC LAMINATE TO BE WILSONART D315-60 "PLATINUM" <br />6. PAINT TO MATCH PLASTIC LAMINATE, SEMI -GLOSS. <br />7. MICROWAVE DUPLEX TO BE INSTALLED W/ EXTENSION AND W/ DEVICE AND COVER <br />PLATE FLUSHED AT FINISHED BACK OF CABINET - SEE ELECT. DWGS. <br />8. COUNTER AND SINK TO BE COMPLETE AND FUNCTIONING IN EVERY ASPECT AND <br />DETAIL AT TIME OF CONSTRUCTION TURNOVER, NO EXCEPTION. <br />9. SEE PLAN TO CONFIRM IF COUNTER IS TO BE RIGHT OR LEFT JUSTIFIED (RIGHT <br />JUSTIFIED SHOWN HERE). LEFT JUSTIFIED IS MIRROR OF THAT SHOWN HERE. <br />? M <br />N <br />H.C. ACCESSIBLE 6" COVE BASE <br />DRINKING FOUNTAINS <br />INTERIOR ELEV. <br />SCALE <br />AT DRINKING FOUNTAINS <br />1/4"=V-0" <br />CENTERLINE OF UPPER ROW MOUNTING HOLES <br />IN BACK WALL OF UNIT. VERIFY THAT THIS <br />MOUNTING HEIGHT WILL GIVE A +34" BED <br />HEIGHT WHEN UNIT IS INSTALLED. SEE <br />MANUFACTURER'S INSTALLATION INSTRUCTIONS <br />FOR ADDITIONAL INFORMATION <br />20 GA. METAL STUDS <br />2"X6" WOOD BLOCKING <br />ATTACHED TO METAL <br />STUDS Wi 3" DRYWALL <br />311 <br />SCREWS. MOUNT <br />BLOCKING FLUSH WITH <br />FACE OF STUD. <br />IN <br />co <br />(0 <br />16" ROUGH <br />OPENING <br />CENTERLINE OF <br />CHANGING STATION <br />LOCKER ROOM COUNTER SCALE 8 <br />1 /2" = 1' - OII <br />FULL HEIGHT FRP, TYPICAL <br />ALL WALLS - NOTCH METAL <br />EDGE TRIM AT ALL <br />RESTROOM ACCESSORIES <br />5/8" EXTERIOR TYPE A-C <br />PLYWOOD UNDER FRP, TYF <br />LAV DEPTH <br />I <br />B <br />A <br />G <br />12" 24" <br />11 G <br />MIN <br />I <br />G <br />CV 1� <br />Z <br />6" COVE BASE <br />TYP <br />ELEVATION 'A' <br />ELEVATION 'A' <br />L HEIGHT FRP, TYPICAL <br />WALLS - NOTCH METAL <br />iE TRIM AT ALL <br />;TROOM ACCESSORIES - <br />EXTERIOR TYPE A-C <br />WOOD UNDER FRP, TYP. <br />DETAIL SCALE 6 <br />DIAPER CHANGING STATION 1/4"=V-0" <br />ELECTRIC <br />ER <br />VB CEILING <br />✓. 12'-0" AFF <br />METAL STRAP, <br />AROUND <br />ER AND <br />VALL <br />PAN <br />ESISTANT <br />f FACE AND <br />PAINTED, <br />ATCH WALL. <br />UM 6-0" SPAN, <br />BADE WOOD, <br />PAINTED. <br />SHELF <br />K <br />DETAIL SCALE <br />WATER HEATER SHELF 1-1/2" = 1' - 0" <br />ELEVATION '6' <br />m, <br />PLUMBING FIXTURES AND ACCESSORIES <br />NOTE: <br />UNLESS OTHERWISE NOTED, ALL TOILET ROOM ACCESSORIES ARE BY BOBRICK. GENERAL CONTRACTOR SHALL <br />PROVIDE AND INSTALL ALL TOILET ACCESSORIES AS NOTED. <br />ITEM <br />DESCRIPTION <br />MANUFACTURER'S ITEM NUMBER <br />OSURFACE <br />MOUNTED TOILET SEAT COVER DISPENSER <br />B-221 <br />40" MAX. A.F.F. TO HIGHEST OPERABLE PART <br />B <br />SURFACE MOUNTED SOAP DISPENSER <br />PROVIDED AND INSTALLED BY <br />40" MAX. A.F.F. TO HIGHEST OPERABLE PART <br />ROSS STORES <br />MOUNTED TOILET TISSUE DISPENSER, 12" MAX. FROM FRONT EDGE OF <br />B-2892 JUMBO <br />OSURFACE <br />TOILET SEAT AND 19" MIN. A.F.F. FROM THE BOTTOM <br />D <br />SURFACE MOUNTED SANITARY NAPKIN DISPOSAL, 40" MAX. A.F.F. TO HIGHEST <br />B-270 <br />OPERABLE PART (WOMEN'S TOILET ROOM ONLY) <br />OE <br />S.S. GRAB BARS WITH CONCEALED MOUNTING, SIDE BAR TO BE 42" MIN. LONG <br />WITH THE FRONT END TO EXTEND 24" BEYOND FRONT EDGE OF TOILET SEAT, BACK <br />B-6806 W/ <br />2562 ANCHOR PLATES <br />BAR TO BE 36" MIN. LONG. SEE ADA-1 FOR MOUNTING HEIGHTS. <br />OF <br />MIRROR W/ S.S. FRAME, 18"x36"; BOTTOM EDGE OF REFLECTIVE SURFACE @ 40" <br />MAX. A.F,F.; CLEAR CAULK MIRROR TO FRP WALL; (MIRRORS ARE PROVIDED IN THE <br />SENTRY MODEL SMS1836 WITH <br />5 REPLACEMENT ANTI GRAFFITI <br />WOMEN'S TOILET ROOM ONLY; NO MIRROR IN THE MEN'S TOILET ROOM.) <br />PLEXI-SHIELDS <br />GO <br />HAND DRYER, SEMI -RECESSED, 40" MAX. A.F.F. TO PROJECTION <br />AMERICAN DRYER EXTREMEAIR <br />EXT7-M (STEEL WHITE) WITH <br />ADA-W RECESS KIT <br />OTIME <br />MIST DISPENSER - MOUNTED @ T-6" A.F.F. <br />MS0260 <br />(SOURCE: BUNZL RETAIL, SEE SHEET T001 FOR CONTACT INFO.) <br />TOILET ROOM PARTITIONS: <br />BOBRICK, DURALINE SERIES <br />ACCESSIBLE STALL DOOR TO BE EQUIPPED WITH AUTOMATIC -CLOSING DEVICE, A <br />1082.67 OVERHEAD BRACED, <br />OI <br />CLEAR OPENING WIDTH OF 34" WITH THE DOOR POSITIONED AT 90° FROM ITS <br />CLOSED POSITION, AND THE INSIDE AND OUTSIDE OF THE DOOR IS TO BE <br />INSTITUTIONAL HARDWARE <br />COLOR: P-500 "BLACK STAR" <br />EQUIPPED WITH A LOOP OR U-SHAPED HANDLE IMMEDIATELY BELOW THE LATCH, <br />DOOR STOPS AT ALL <br />THE LATCH HARDWARE SHALL NOT REQUIRE THE USER TO GRASP OR TWIST IN <br />PARTITION DOORS <br />ORDER TO OPERATE <br />JO <br />DIAPER CHANGING STATION <br />WHEN OPEN TOP OF TABLE TO BE 34" MAX. A.F.F. <br />BCS-2 <br />(SOURCE: GAMCO, SEE SHEET T001 FOR CONTACT INFO.) <br />ACCESSIBLE WATER CLOSET: KOHLER HIGHCREST TOILET K-4302 (1.6 GPF) WITH K 4670 C SEAT AND SLOAN ROYAL <br />1 A <br />110 EXPOSED FLUSH VALVE (3.5 GPF) WITH VACUUM BREAKER AND STOP. MAXIMUM 5-POUND-FORCE REQ'D FOR <br />ACTIVATION. SEE ADA-1 FOR MOUNTING HEIGHTS. <br />WATER CLOSET: KOHLER WELCOMME K-4350 (1.6 GPF) WITH K-4670-C SEAT AND SLOAN ROYAL 110 EXPOSED FLUSH <br />1 B <br />VALVE (3.5 GPF) WITH VACUUM BREAKER AND STOP. <br />RESTROOM LAVATORY: AMERICAN STANDARD, LUCERNE 0355.012 WHITE, WITH HERITAGE CENTERSET FAUCET <br />5402.172V.002 WITH WRIST HANDLES. FAUCET CONTROLS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT <br />TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST WITH A MAXIMUM 5-POUND-FORCE REQ'D FOR <br />OREQUIRE <br />ACTIVATION. SEE ADA-1 FOR MOUNTING HEIGHTS. HOT WATER AND DRAIN PIPES UNDER ALL LAVATORIES SHALL BE <br />INSULATED WITH TRUEBRO LAVGUARD DEVICE OR APPROVED EQUAL (PIPE WRAP IS NOT ALLOWED); THERE SHALL BE <br />NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES <br />Illy <br />KOHLER, BARDON HIGH EFFICIENCY K-4904-ET WHITE. RIM TO PROJECT 14" MIN. AND 19" MAX. FROM WALL <br />AND <br />AND 17" MAX. A.F.F. <br />4 <br />JANITOR CLOSET SERVICE SINK: FLORESTONE MODEL #91 36"X 24"X 12" WITH STAINLESS STEEL CAP. FAUCET: <br />CENTRAL BRASS #0054-YELSRC-Q SERVICE SINK FAUCET. <br />ODRINKING <br />FOUNTAIN: HALSEY-TAYLOR BARRIER -FREE HACBLSS-LR NEW NON REFRIGERATED WATER COOLER TWIN, <br />NO SUBSTITUTION - SEE ADA-1 FOR MOUNTING HEIGHTS. CONTACT FERGUSON CORP. SALES -(757) 939-2639 <br />6 <br />ELECTRIC 4 KW / 10 QUICK RECOVERY GALLON WATER HEATER. HOT WATER HEATER MUST NOT EXCEED 60 FEET <br />FROM HEATER TO TAP. ALL HOTWATER LINES MUST BE INSULATED. SEE 5/A401 FOR WATER HEATER SHELF. <br />CONFIRM THAT SIZE MATCHES OR EXCEEDS CODE MINIMUM. <br />LOCKER ROOM SINK - ELKAY GECR2521 STAINLESS STEEL SINK W/ UNDERSEAL; AMERICAN STANDARD, HERITAGE <br />FAUCET W/ WRIST BLADE HANDLES. FAUCET CONTROLS SHALL BE OPERABLE WITH ONE HAND AND <br />O7400.172H.002 <br />7 <br />SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST WITH A MAXIMUM 5-POUND-FORCE <br />REQ'D FOR ACTIVATION. SEE ADA-1 FOR MOUNTING HEIGHTS. HOT WATER AND DRAIN PIPES UNDER THE COUNTER <br />SHALL BE INSULATED OR OTHERWISE COVERED, THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER THE <br />CABINET <br />8 <br />MARBLE THRESHOLD, DAL -TILE CARRERA. <br />TOILET ROOM NOTES <br />1. <br />GRAB BARS TO BE 1 1/2" DIAMETER, 1 1/2" CLEAR FROM WALL, BOBRICK #B-6806. <br />2. <br />ALL OPERABLE FIXTURE COMPONENTS OR LEVERS TO BE MOUNTED 40" MAX. ABOVE FINISH FLOOR <br />3. <br />HOT WATER, COLD WATER AND DRAIN PIPES UNDER LAVATORIES TO BE THERMALLY INSULATED <br />4. <br />HANDICAP TOILET TO HAVE TOP OF SEAT BETWEEN 17" & 19" A.F.F. OR AS REQ'D BY LOCAL CODES. <br />5. <br />TOILET COMPARTMENT DOORS TO BE SELF -CLOSING <br />6. <br />PROVIDE FLOOR DRAINS IN TOILET ROOMS AND JANITORS CLOSET. G.C. TO SLOPE NEW CONCRETE OR FLOAT TILE <br />AS REQUIRED FOR PROPER DRAINAGE. DEMO/TRENCH EXIST. SLAB AS REQ'D. DO NOT LOCATE TOILET PARTITIONS <br />OVER FLOOR DRAINS. <br />7. <br />PROVIDE EXHAUST FAN AT LOCKER ROOM, RESTROOMS, JANITOR'S AND EQUIPMENT CLOSET. FAN TO BE A <br />T-STAT-CONTROLLED (24/7) DEVICE - SEE MECHANICAL DRAWINGS. <br />8. <br />INSTALL ROSS PROVIDED SIGNAGE IN CONFORMANCE WITH LOCAL CODES AND ADA REQUIREMENTS. COORDINATE <br />WITH ROSS CONSTRUCTION MANAGER. (G.C. TO PROVIDE TEMP. ADA SIGNS UNTIL ROSS'S PROTOTYPICAL SIGNS <br />ARE PROVIDED) <br />9. <br />CONTRACTOR MUST PROVIDE SOLID IN WALL BLOCKING FOR ALL TOILET ROOM ACCESSORIES AND PARTITIONS. <br />10. <br />PROVIDE & INSTALL ALL TOILET ROOM SIGNS REQ'D BY LOCAL, STATE & FEDERAL LAWS, INCLUDING ADA. SIGNS <br />MUST COMPLY WITH SIZE, TEXT, BRAILLE, GRAPHIC STANDARDS AND BE LOCATED IN COMPLIANCE W1 APPLICABLE <br />REGULATIONS. <br />6/A401 <br />ELEVATION 'C' <br />NOTES I SCALE <br />PLUMBING FIXTURES & ACCESSORIES NONE <br />FULL HEIGHT FRP, TYPICAL <br />ALL WALLS - NOTCH METAL <br />EDGE TRIM AT ALL <br />RESTROOM ACCESSORIES <br />5/8" EXTERIOR TYPE A-C <br />PLYWOOD UNDER FRP, TYF <br />17" MIN <br />LAV DEPTH <br />`6" COVE BASE <br />ELEVATION 'D' <br />MEN'S ROOM ELEVATION SCALE <br />1 /4" = V-0" <br />FULL HEIGHT FRP, TYPICAL <br />ALL WALLS - NOTCH METAL <br />EDGE TRIM AT ALL <br />RESTROOM ACCESSORIES- <br />5/8" EXTERIOR TYPE A-C <br />PLYWOOD UNDER FRP, TYP. <br />I F I I <br />J A H A <br />54" MIN B \ B E <br />2" 42" \ 24" 12" <br />MIN. MIN <br />c� co C \ <br />N 111I-P r% i . 1% 1 1 - -5 (+ D (+ <br />)y C 6" COVE BASE D C 6" COVE BASE SEE DETAIL �L 6" COVE LASE <br />6/A401 6" 18' 6"-1 <br />TYP TYF <br />ELEVATION 'B' ELEVATION 'C' ELEVATION 'D' <br />ACCESSIBILITY NOTES: <br />1. (1)FITTING ROOM SHALL BE PROVIDED FOR MALE AND <br />FEMALE CUSTOMERS. <br />2. ENTRY DOORS SHALL PROVIDE: <br />a) >t 32" CLEARANCE <br />b) >_ 18" STRIKE EDGE <br />3. A MIN. 24"x 48" BENCH SHALL BE PROVIDED BY ROSS: <br />a) FIXED ALONG LONG SIDE <br />b) MOUNTED >_ 17" BUT NOT LESS THAN 9". <br />NOTE: <br />REFER TO SHEET ADA-1 FOR <br />DETAILED FITTING ROOM REQ. <br />NOTE: <br />A TENANT SPECIFIED FIXTURE VENDOR <br />AND INSTALLATION CONTRACTOR WILL <br />PROVIDE AND INSTALL FITTING ROOM <br />PARTITIONS, HARDWARE, AND <br />ACCESSORIES (MIRRORS, GRAB BARS, <br />ETC.) CONTACT TENANT FOR THE NAME <br />OF THE INSTALLING CONTRACTOR AND <br />TO COORDINATE AND SCHEDULE THE <br />WORK WITH THE INSTALLER <br />NOTE: <br />ALL DIMENSIONS ARE FROM <br />FINISH FACE OF WALLS. HOLD <br />DIMENSIONS ARE CRITICAL <br />AND SHALL BE MAINTAINED. <br />HOLD=CLEAR. <br />PROVIDE RESTROOM <br />IDENTIFICATION SIGNAGE. <br />SEE DOOR & HARDWARE <br />NOTE #22 ON A601. TYP. <br />NO SUBSTITUTIONS WILL BE <br />ACCEPTED <br />WALL DIMENSIONS IN THE <br />FITTING ROOMS ARE CRITICAL. <br />FAILURE TO MAINTAIN THE <br />DIMENSIONS GIVEN IN THE <br />ARCHITECTURAL PLAN MAY <br />RESULT IN REJECTION OF THE <br />WORK. <br />NOTE: <br />ANY DEVICE THAT WOULD BE <br />OPERABLE IN A COMMON OR <br />PUBLIC SPACE SHALL BE AT <br />ACCESSIBLE REACH RANGES <br />(TO THE HIGHEST OPERATING <br />PART OF DEVICE) AT 48" MAX <br />AND 15" MIN, TYP. <br />NOTE: <br />PROVIDE CONTINUOUS MARBLE <br />THRESHOLD @ TRANSITION <br />FROM VCT TO CERAMIC TILE - <br />COLOR TO MATCH CERAMIC <br />TILE, TYP. @ RMS 114, 115, 116. <br />LEGEND <br />L CORNER GUARD - (CG-1 OR CG-2) SEE 3/A202 <br />FOR MORE FINISH LEGEND INFORMATION <br />INDICATES 4'-0" H PANELS <br />INDICATES 6-0" H PANELS <br />PAINT P-1 ABOVE PANELS U.N.O. ON PLAN. <br />NOTE: G.C. TO VERIFY EXACT LOCATIONS OF RIGID WALL <br />COVERING WITH ROSS C.P.M. - SEE DETAIL 8/A501 <br />NOTE: <br />REFER TO SHEET A501 FOR <br />WALL PARTITION TYPES. <br />E <br />E: G.C. TO VERIFY EXACT <br />ATIONS OF RIGID WALL <br />ERING WITH BOSS C.P.M. <br />N <br />WOMEN'S ROOM ELEVATION SCALE ENLARGED OFFICE GROUP PLAN SCALE <br />i 1/111-11 N1 1 1 /^II - it nll <br />mcg architecture <br />TT 216.520,1551 FT 216.520.1567 <br />7100 E. Pleasant Valley Rd., Suite 320, Cleveland, OH 44131 <br />Seal: <br />A Project for: <br />Client: <br />ROSS STORES, INC. <br />4440 ROSEWOOD DRIVE <br />PLEASANTON, CA 94588 <br />Revisions: <br />AB ADDENDUM B <br />04-12-13 <br />BID/PERMIT <br />02-14-13 <br />No. Description <br />Project No.: <br />Date <br />11.594.01 <br />Drawn By: <br />LMS <br />Reviewed By: <br />BCB <br />Scale: <br />NOTED <br />Date: <br />01-28-2013 <br />Filename: 11 594A401 <br />Sheet Title: <br />ENLARGED PLANS, <br />INTERIOR ELEVATIONS <br />AND DETAILS <br />Sheet #: <br />A401 <br />@ MCG ARCHITECTS 2011 ALL RIGHTS RESERVED <br />- - - -- <br />I i <br />i .. - Fl SII-lI Ili �(�il��l�l ��r,„'. bi n.�f� .I �-1I71--J-i_-- _.___.. ..I. _--TT- I <br />