STRUCTURAL GENERAL NOTES <br />CODE: FLORIDA BUILDING CODE <br />YEAR: 2010 <br />LIVE LOADS <br />ROOF -- 20 PSF <br />NOTE: LOADS REDUCED FOR AREA BASED ON FBC REQUIREMENTS <br />ROOF SNOW LOAD <br />GROUND SNOW LOAD (Pg) = <br />0 PSF <br />FLAT ROOF SNOW LOAD (Pf) = <br />0 PSF <br />SNOW EXPOSURE FACTOR (Ce) = <br />1.0 <br />SNOW LOAD IMPORTANCE FACTOR (Is) = <br />1.0 <br />THERMAL FACTOR (Ct) = <br />1.0 <br />WIND LOADS <br />BASIC WIND SPEED: V3S = <br />130 MPH <br />WIND IMPORTANCE FACTOR (Iw) = <br />1.0 <br />OCCUPANCY CATEGORY = <br />II <br />WIND EXPOSURE = <br />C <br />TOPOGRAPHIC FACTOR Kzt = <br />1.0 <br />INTERNAL PRESSURE COEFFICIENT (GCpi) <br />f.18 <br />ENCLOSURE CLASSIFICATION = <br />ENCLOSED <br />NOTE: WIND LOADS FOR COMPONENTS AND <br />CLADDING SHALL CONFORM TO IBC <br />CRITERIA. THE CLADDING SUPPLIERS SHALL CONSIDER INCREASED <br />PRESSURE COEFFICIENTS FOR COMPONENTS <br />AND CLADDINGS AND <br />DETERMINE THE APPROPRIATE WIND <br />LOADS FOR THEIR SYSTEMS BASED <br />ON ZONE AND EFFECTIVE WIND AREA. <br />SPECIAL LOADS <br />INTERIOR WALLS - LATERAL LOAD - 5 PSF <br />HANDRAIL - LOADS IN ACCORDANCE WITH IBC SECTION 1607.7.1 <br />GENERAL <br />THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE <br />RENOVATION IS FULLY COMPLETED. IT IS THE CONTRACTOR'S SOLE <br />RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND INSURE <br />THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. <br />THIS INCLUDES THE ADDITION OF WHATEVER SHORING, TEMPORARY BRACING, ETC. <br />THAT MAY BE NECESSARY. SUCH MATERIAL SHALL REMAIN THE CONTRACTOR'S <br />PROPERTY AFTER COMPLETION OF THE PROJECT. <br />FIELD VERIFY ALL DIMENSIONS AND CONDITIONS OF EXISTING CONSTRUCTION. <br />WORK THESE DRAWINGS WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL <br />DRAWINGS. <br />�il�L1�7_ffii]►1 <br />THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE SURVEY AND THE <br />SUB -SURFACE INVESTIGATION REPORT BEFORE STARTING CONSTRUCTION. ALL <br />FOUNDATION WORK SHALL BE IN ACCORDANCE WITH THE RECOMMENDATIONS OF <br />THE SOILS REPORT BY UNIVERSAL ENGINEERING SERVICES DATED MAY 2, 2012 <br />EXCEPT WHERE NOTED OTHERWISE ON DRAWINGS OR SPECIFICATIONS. <br />A SOILS TESTING LABORATORY SHALL BE RETAINED BY THE CONTRACTOR TO <br />PROVIDE CONSTRUCTION REVIEW TO INSURE CONFORMANCE WITH THE <br />CONSTRUCTION DOCUMENTS DURING THE EXCAVATION, BACKFILL, AND <br />FOUNDATION PHASES OF THE PROJECT. <br />THE SOILS TESTING LABORATORY SHALL: DISCUSS WITH THE ENGINEER THE <br />DESIGN INTENT OF THE CONSTRUCTION DOCUMENTS AND THE TESTING <br />PROCEDURES USED TO INSURE CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS <br />BEFORE CONSTRUCTION BEGINS. INFORM THE ENGINEER OF ANY VARIANCE IN <br />THESE PROCEDURES, <br />IT SHALL BE THE RESPONSIBILITY OF THE SOILS TESTING LABORATORY TO <br />VERIFY ASSUMED BEARING PRESSURE, DETERMINE EXCAVATION STRIPPING DEPTH; <br />INSPECT ALL SUBSOIL EXPOSED DURING EXCAVATION OPERATIONS; APPROVE FILL <br />MATERIALS, PERFORM DENSITY TESTS OF FILLS TO INSURE PLACEMENT PER SOILS <br />ENGINEER REQUIREMENTS; INSPECT FOUNDATION BEARING SURFACES. <br />FOUNDATION DESIGN IS BASED ON AN ASSUMED 1500 PSF BEARING PRESSURE <br />MINIMUM ON APPROVED SOIL. BEARING PRESSURE SHALL BE VERIFIED BY THE SOILS <br />ENGINEER. <br />INUNDATION AND LONG TERM EXPOSURE OF BEARING SURFACES, WHICH WILL <br />RESULT IN DETERIORATION OF BEARING FORMATIONS, SHALL BE PREVENTED. <br />FOOTINGS SHALL BE PLACED IMMEDIATELY FOLLOWING FOOTING EXCAVATIONS <br />AND BEARING SURFACE INSPECTION. <br />ALL FILL MATERIALS SHALL BE FREE OF ORGANIC CONTAMINATIONS AND OTHER <br />DELETERIOUS MATTER. <br />FOR BACKFILL AGAINST FOOTINGS, ETC., PLACE IN 8" THICK LAYERS, WITH EACH <br />LIFT COMPACTED AT NEAR OPTIMUM MOISTURE CONTENT, IN ACCORDANCE WITH THE <br />SOILS ENGINEER?S RECOMMENDATIONS. <br />NOTIFY STRUCTURAL ENGINEER OF ANY UNUSUAL SOIL CONDITIONS. <br />CONCRETE <br />ALL CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH IN 28 DAYS <br />AS FOLLOWS: <br />SITE CONCRETE, DOCK WALLS AND CONCRETE EXPOSED TO WEATHER - 4,000 PSI. <br />ALL OTHER CONCRETE INCLUDING SLABS AND FOOTINGS - 3,000 PSI. <br />REINFORCING BARS SHALL BE NEW BILLET STEEL BARS CONFORMING TO <br />ASTM A-615, GRADE 60 (60,000 PSI YIELD). <br />NO TACK WELDING OF REINFORCING IN THE FIELD WILL BE PERMITTED. <br />WELDED WIRE MESH REINFORCING SHALL CONFORM TO ASTM A-185. <br />ALL CONCRETE CONSTRUCTION SHALL CONFORM TO ACI 301, "SPECIFICATIONS <br />FOR STRUCTURAL CONCRETE FOR BUILDINGS" UNLESS NOTED OTHERWISE. <br />ALL DETAILING, FABRICATION AND PLACING OF REINFORCING BARS, UNLESS <br />OTHERWISE NOTED, SHALL CONFORM TO ACI 318, "BUILDING CODE <br />REQUIREMENTS FOR REINFORCED CONCRETE" AND THE LATEST ACI "MANUAL OF <br />STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES." <br />STRUCTURAL STEEL <br />ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A-992 GRADE 50 (FY = 50 KSI) <br />EXCEPT TUBULAR SECTIONS WHICH SHALL CONFORM TO ASTM A-500 GRADE "B" <br />(FY = 46 KSI). ANGLES, CHANNELS, PLATES, AND BARS SHALL CONFORM TO <br />ASTM A-36 (FY = 36 KSI) AS A MINIMUM. <br />DETAILING, FABRICATION, AND ERECTION SHALL CONFORM TO THE LATEST AISC <br />SPECIFICATIONS. <br />COMPLY WITH PROVISIONS OF THE FOLLOWING AISC SECTION, EXCEPT AS OTHERWISE <br />INDICATED: <br />1. AISC "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES" <br />(2005). <br />a. PARAGRAPH 3.3 OF THE ABOVE CODE IS HEREBY MODIFIED BY <br />DELETION OF THE FOLLOWING SENTENCE: "WHEN DISCREPANCIES <br />BETWEEN DRAWINGS AND SPECIFICATIONS FOR BUILDINGS, THE <br />DESIGN DRAWINGS GOVERN." REPLACE WITH: "WHEN DISCREPANCIES <br />BETWEEN DRAWINGS AND SPECIFICATIONS FOR BUILDINGS, THE MORE <br />STRINGENT REQUIREMENTS GOVERN, UNLESS DETERMINED OTHERWISE <br />BY THE ARCHITECT/ENGINEER." <br />b. PARAGRAPH 4.1 OF THE ABOVE CODE IS HEREBY MODIFIED AS <br />FOLLOWS: PLANS PROVIDED AS PART OF A BID PACKAGE ARE NOT <br />TO BE CONSIDERED TO BE RELEASED FOR CONSTRUCTION UNLESS <br />SPECIFICALLY NOTED ON THE DRAWINGS. <br />c. PARAGRAPH 4.4 OF THE ABOVE CODE IS HEREBY MODIFIED BY <br />DELETION OF THE FOLLOWING SENTENCE: "THESE DRAWINGS SHALL <br />BE RETURNED TO THE FABRICATOR WITHIN 14 CALENDAR DAYS." <br />ADD THE FOLLOWING: "THE FABRICATOR SHALL INCLUDE A <br />SUFFICIENT AMOUNT OF TIME FOR RETURN OF SHOP DRAWINGS <br />TO ALLOW 10 WORKING DAYS FOR REVIEW BY THE STRUCTURAL <br />ENGINEER. THIS MAY BE WAIVED ON SPECIFIC SUBMITTALS <br />WITH PRIOR CONCURRENCE OF STRUCTURAL ENGINEER. <br />FABRICATOR SHALL SUBMIT PROPOSED SCHEDULE OF SHOP <br />DRAWING SUBMITTALS AT START OF DETAILING." <br />d. PARAGRAPH 4.4.2 OF THE ABOVE CODE IS HEREBY MODIFIED BY <br />ADDITION OF THE FOLLOWING: "IF ANY OF THE ADDITIONS, <br />DELETIONS OR CHANGES MARKED ON THE SHOP DRAWINGS RESULTS <br />IN AN ADDITIONAL COST AND/OR TIME REQUIRED TO FABRICATE <br />AND ERECT; A PROPOSED CHANGE ORDER, DETAILING THE ADDED <br />COST AND/OR TIME REQUIRED, SHALL BE SUBMITTED TO THE OWNER <br />FOR APPROVAL. THIS CHANGE ORDER SHALL BE APPROVED BEFORE <br />THE WORK AFFECTED PROCEEDS." <br />e. PARAGRAPH 9.4.2 OF THE ABOVE CODE IS HEREBY MODIFIED BY <br />ADDITION OF THE FOLLOWING: "IF ANY OF THE REVISIONS <br />RESULTS IN AN ADDITIONAL COST AND/OR TIME TO FABRICATE <br />AND ERECT; A PROPOSED CHANGE ORDER, DETAILING THE ADDED <br />COST AND/OR TIME REQUIRED, SHALL BE SUBMITTED TO THE OWNER <br />FOR APPROVAL. THIS CHANGE ORDER SHALL BE APPROVED BEFORE <br />THE WORK AFFECTED PROCEEDS." <br />2. ALL CONSTRUCTION PROCEDURES AND DETAILING AND FABRICATION OF <br />STRUCTURAL STEEL SHALL CONFORM WITH THE LATEST OSHA REQUIREMENTS <br />AND RECOMMENDATIONS. <br />ALL STRUCTURAL STEEL SHALL BE SHOP PRIMED; ASPHALTIC PAINTS ARE NOT <br />ACCEPTABLE. <br />FIELD CONNECTIONS SHALL BE BOLTED, BEARING TYPE UNLESS NOTED OTHERWISE, <br />USING 3/4" HIGH STRENGTH BOLTS CONFORMING TO ASTM A-325. ONE SIDED <br />CONNECTIONS ARE NOT PERMITTED UNLESS DETAILED ON DRAWINGS. <br />ALL WELDING SHALL BE DONE USING E-70XX ELECTRODES IN ACCORDANCE WITH <br />THE LATEST AWS SPECIFICATIONS. <br />GENERAL CONTRACTOR SHALL VERIFY ALL STRUCTURAL BEAM LOCATIONS, <br />MECHANICAL UNIT WEIGHTS AND OPENING SIZES AND LOCATIONS WITH MECHANICAL <br />CONTRACTOR AND VENDOR'S DRAWINGS FOR ACTUAL -MECHANICAL UNIT PURCHASED. <br />ALL 4 X 4 X 5/16 ANGLES REQUIRED FOR ROOF UNITS AND ROOF OPENINGS OVER <br />12" X 12" BE SUPPLIED BY STRUCTURAL STEEL FABRICATOR AND BE COORDINATED <br />BY GENERAL CONTRACTOR WITH THE JOIST FABRICATOR, MECHANICAL DRAWINGS <br />AND MECHANICAL EQUIPMENT SUPPLIER. <br />FIELD VERIFY ALL CONDITIONS AT AND CONNECTIONS TO THE EXISTING <br />CONSTRUCTION BEFORE FABRICATION. <br />SUBMIT SHOP DRAWINGS PREPARED UNDER THE SUPERVISION OF A REGISTERED <br />STRUCTURAL ENGINEER, INCLUDING COMPLETE DETAILS AND SCHEDULES FOR <br />THE FABRICATION AND ASSEMBLY OF STRUCUTRAL STEEL MEMBERS, PROCEDURES <br />AND DIAGRAMS. INCLUDE DETAILS OF CUTS, CONNECTIONS, CAMBER, HOLES, <br />AND OTHER PERTINENT DATA. INDICATE WELDS BY STANDARD AWS SYMBOLS AND <br />SHOW SIZE, LENGTH, AND TYPE OF EACH WELD. AISC STANDARD DOUBLE ANGLE <br />CONNECTION DETAILS SHALL BE USED FOR ALL CONNECTIONS THAT ARE NOT <br />OTHERWISE DETAILED ON THE DRAWINGS. WHERE THE REACTIONS OF BEAMS <br />AND GIRDERS ARE NOT SHOWN ON THE DRAWINGS, THE CONNECTIONS SHALL BE <br />DESIGNED TO SUPPORT THE MAXIMUM ALLOWABLE UNIFORM LOAD AS INDICATED IN <br />THE LOAD TABLES OF THE AISC MANUAL OF STEEL CONSTRUCTION FOR THE GIVEN <br />BEAM SIZE AND SPAN. <br />METAL ROOF DECKING <br />ALL METAL ROOF DECKING SHALL COMPLY WITH THE PROVISIONS OF THE "STEEL ROOF <br />DECK DESIGN MANUAL", SDI, LATEST EDITION, AND FACTORY MUTUAL REQUIREMENTS. <br />DECK AND ACCESSORIES SHALL BE CLEANED AND GIVEN A PHOSPHATE TREATMENT <br />AND A SHOP PRIME COAT OF RUST INHIBITIVE PAINT. <br />CONNECTIONS TO STEEL SUPPORTS SHALL BE FUSION TYPE WELDS PERFORMED BY <br />COMPETENT WELDERS WHO HAVE QUALIFIED BY TESTS AS PRESCRIBED BY THE <br />AMERICAN WELDING SOCIETY TO PERFORM THE TYPE OF WORK REQUIRED. ROOF <br />DECK SHALL BE PLUG WELDED (5/8" DIAMETER MINIMUM) TO THE SUPPORTS AT <br />6" CENTERS (36/7 WELD PATTERN). THE FIRST AND LAST RIBS OF EACH SHEET <br />MUST BE WELDED TO ALL SUPPORTS. END WELDS AND THOSE OCCURRING AT LAPS <br />SHALL BE WELDED THROUGH ALL THICKNESSES. SIDE JOINTS SHALL BE MECHANICALLY <br />FASTENED W/(9)-#10 SCREWS AT 12" CENTERS. <br />NO LIGHT GAGE FRAMING, MECHANICAL, ELECTRICAL OR OTHER EQUIPMENT SHALL <br />BE SUSPENDED FROM OR ATTACHED TO ANY METAL DECK. <br />SPECIAL INSPECTIONS PER 2010 FBC SECTION 1704 <br />THE OWNER SHALL EMPLOY A REGISTERED ENGINEER OR TEST AGENCY WITH <br />EXPERIENCED TECHNICIANS UNDER THE DIRECT SUPERVISION OF A REGISTERED <br />ENGINEER TO PERFORM THE DUTIES OF THE SPECIAL INSPECTOR. THE SPECIAL <br />INSPECTOR SHALL MEET THE QUALIFICATIONS AS STATED IN THE BUILDING CODE. <br />DUTIES AND RESPONSIBILITIES OF THE INSPECTOR: <br />THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED FOR CONFORMANCE <br />WITH THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS, AND THE FOLLOWING <br />TABLE. <br />THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING <br />OFFICIAL, THE ENGINEER OR ARCHITECT OF RECORD AND OTHER DESIGNATED <br />PERSONS. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION <br />OF THE CONTRACTOR FOR CORRECTION, THEN, IF UNCORRECTED, TO THE PROPER <br />DESIGN AUTHORITY AND TO THE BUILDING OFFICIAL. <br />THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL SIGNED REPORT STATING <br />WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS TO THE BEST OF THE <br />INSPECTOR'S KNOWLEDGE, IN CONFORMANCE WITH THE APPROVED PLANS AND <br />SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE CURRENT <br />BUILDING CODE. REPORTS SHALL COMPLY WITH THE REQUIREMENTS OF IBC <br />SECTION 1704.1. <br />STATEMENT OF SPECIAL INSPECTIONS SCHEDULE <br />The areas marked below shall have special <br />inspections <br />Continuous <br />Periodic <br />Remarks <br />❑ Inspection of Fabricators (1704.2) <br />❑ Other <br />X Steel Construction (1704.3) <br />X Materials <br />❑ Welding <br />❑ Steel frame details <br />❑ High -strength bolts <br />❑ Structural steel (1707.2 & 1708.4) <br />❑ Other <br />X <br />X Concrete Construction (1704.4 & 1708.3) <br />X Reinforcing steel <br />❑ Conc Placement <br />❑ Prestressed <br />X Sampling & Strength tests <br />❑ Bolts in concrete <br />❑ Shotcrete <br />❑ Precast <br />X Other: Adhesive & expansion anchors <br />X <br />X <br />X <br />1704.13 <br />❑ Masonry Construction (1704.5) <br />❑ Essential facility glass units & <br />veneer -- Level 1 <br />❑ Nonessential facility- Level 1 <br />❑ Essential facility-- Level 2 <br />❑ Other <br />❑ Wood Construction (1704.6) <br />❑ High Load diaphragms <br />❑ Structural wood (1707.3) <br />❑ Other <br />X Soils (1704.7) <br />❑ Site preparation <br />❑ In -place density <br />❑ Fill placement <br />X Other: Allowable bearing capacity 1500 PSF <br />X <br />❑ Pile Foundations (1704.8) <br />❑ Other <br />❑ Pier Foundations (1704.9 & 1707.5) <br />❑ Other <br />❑ Spray fire-resistant mated als (1704.10) <br />❑ Other <br />❑ Fire-resistant coatings (1704.11) <br />❑ Other <br />STATEMENT OF SPECIAL INSPECTIONS SCHEDULE <br />The areas marked below shall have special <br />inspections <br />Continuous <br />Periodic <br />Remarks <br />❑ Exterior insulation & finish [EIFS] (1704.12) <br />❑ Other <br />❑ Special Cases (1704.13) <br />❑ Other <br />❑ Smoke control (1704.14) <br />❑ Other <br />❑ MEP Components (1705.3 & 1707.8) <br />❑ Emergency electrical <br />❑ Hazardous piping <br />❑ Hazardous ductwork <br />❑ Vibration isolation systems <br />❑ Other <br />❑ Architectural Components (1705.3,1707.6 <br />& 1707.7) <br />❑ Exterior wall panels <br />❑ Veneer (<5 psf) <br />❑ Suspended ceilings <br />❑ Access floors <br />❑ Storage racks (<8ft) <br />❑ Other <br />❑ Cold -formed steel (1707.4) <br />❑ Welding <br />❑ Fastening <br />❑ Other <br />❑ Seismically isolated structures (1708.6) <br />❑ Seismic Design Category <br />❑ C ❑ D ❑ E ❑ F <br />❑ Seismic -Force -Resisting Systems <br />❑ Structural Steel <br />❑ Structural Wood <br />❑ Cold -Formed Steel Framing <br />❑ Seismic Isolation Systems <br />❑ Other <br />❑ Designated Seismic Systems <br />❑ Importance factor >1 <br />❑ Architectural <br />❑ Mechanical <br />❑ Electrical <br />❑ Other <br />IK Structural Observation (1709) <br />❑ Yes <br />X No <br />SAWCUT (E) SLAB <br />#4x2'-0" LG <br />#4x2 2'-0" C C AS REQ'D FOR REPAIR <br />/ AREAS OR POUR TO <br />EMBED 6" INTO (E) (E) LEAVEOUT FOR <br />SLAB W/HILTI SEE PLANS (N) WORK (TYP) <br />HIT-HY150 MAX FOR LIMITS OF <br />MDIDEDEPTSIVE HTMP) @ SLAB REPAIR (E) SLAB <br />CLEAN (E) CONC - <br />SURFACE & APPLY <br />BONDING COMPOUND <br />(TYP) <br />VAPOR <br />RETARDER <br />4" COMPACTED GRANULAR <br />MATERIAL & FILL <br />BELOW AS REQUIRED <br />TYP SLAB INFILL/REPAIR DETAIL <br />3/4 "=1'-0" <br />E) EXISTING <br />N) NEW <br />FV) FIELD VERIFY <br />NOTE: <br />ALL DIMENSIONS OF EXISTING STRUCTURE <br />ARE APPROXIMATE AND SHALL BE FIELD <br />VERIFIED BY THE CONTRACTOR PRIOR TO <br />FABRICATION. <br />NOTE: <br />SCALES INDICATED ARE BASED ON FULL <br />SIZE 30"x42" DRAWING <br />DIMENSIONS SHALL NOT BE DETERMINED <br />Shenberger do Associates, Inc. <br />Structural Engineers <br />8227 Brecksville Road <br />Cleveland, Ohio 44141 <br />Telephone: (440) 526-3100 <br />Fax: (440) 526-7753 <br />EMAIL: soi®shenberger.net <br />mcg architecture <br />T 216.520.1551 © 216.520.1567 <br />7100 E. Pleasant Valley Rd., Suite 320, Cleveland, OH 44131 <br />Seal: <br />111141 <br />tGlALL.4 <br />lj <br />C E NSF <br />* No 7"63 <br />�O STATE OF � ZZ <br />�L ORIV <br />A Project for: <br />Client: <br />ROSS STORES, INC. <br />4440 ROSEWOOD DRIVE <br />PLEASANTON, CA 94588 <br />Revisions: <br />BID/PERMIT <br />02-14-13 <br />No. Description <br />Date <br />Project No.: <br />11.594.01 <br />Drawn By: <br />SAI <br />Reviewed By: <br />SAI <br />Scale: <br />AS NOTED <br />Date: <br />01-28-2013 <br />Filename: <br />Sheet Title: <br />STRUCTURAL <br />GENERAL NOTES <br />SECTIONS & DETAILS <br />Sheet #: <br />S001 <br />© MCG ARCHITECTS 2011 ALL RIGHTS RESERVED <br />