KEYED NOTES <br />01 SUSPENDED HAT -CHANNEL CEILING GRID TO RECEIVE VINYL <br />PANEL CEILING BY CARWASH EQUIPMENT VENDOR - COORDINATE <br />DIRECTION OF HAT CHANNEL WITH VINYL PANEL INSTALLER - SEE <br />WALL SECTIONS <br />�2 SMOOTH SAND STUCCO FINSH SOFFIT / CEILING - SEE SECTIONS - <br />PAINT COLOR TO MATCH MAIN FIELD OF EXTERIOR ELEVATIONS - <br />SEE ELEVATIONS <br />1�3 CONTROL JOINT IN STUCCO CEILING <br />OEXTERIOR LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS. <br />5 NOT USED <br />6 NOT USED <br />OACCESS DOOR TO ROOF - SEE DOOR SCHEDULE <br />V MASONRY HEADER - SEE STRUCTURAL <br />OROOF ACCESS LADDER - SEE DETAIL 2/A5e <br />10 OVERHEAD ROLL -UP DOOR <br />11 2'X2' ACCESS PANEL IN CEILING - GC TO COORDINATE ACCESS <br />PANEL WITH ALL FRAMING / MTL DECK AS NECESSARY <br />12 ROOF AREA BELOW - SEE ROOF PLAN <br />13 NO CEILING IN THIS AREA - REFER TO ELECTRICAL FOR LIGHTING <br />14 NOT USED <br />15 MASONRY WALL TO BOTTOM OF DECK - SEE STRUCTURAL <br />DRAWINGS t WALL SECTIONS <br />ib THRU WALL LOUVER ABOVE LOUVERED DOORS - COORDINATE <br />OPENING WITH STRUCTURAL AND SEE MECHANICAL DRAWINGS <br />FOR MORE INFORMATION <br />11 SURFACE MOUNTED LIGHT FIXTURE ATTACHED BOTTOM SIDE OF <br />MEZZANINE DECK - SEE ELECTRICAL DRAWINGS <br />18 EXHAUST DUCT TO EXHAUST FAN ON ROOF - SEE MECHANICAL <br />DRAWINGS FOR MORE INFORMATION. <br />19 WALL MOUNTED FAN. GREENHECK AX-31-160-0434-A3 WITH <br />SCREEN, CONTROL WITH ON OFF SWITCH. <br />20 CONT. P4000 UNISTRUT SYSTEM TO RUN FULL LENGTH OF TUNNEL. <br />JOIN SEGMENTS TOGETHER WITH P1061 EG PLATES HUNG FROM <br />BOTTOM CHORD OF JOISTS. SPACE UNISTRUT AT 1'-0" APART <br />CENTERED IN TUNNEL - SEE REFLECTED CEILING PLAN AND WALL <br />SECTIONS. <br />21 APPROXIMATE CAMERA LOCATIONS - FINAL ANGLE AND <br />LOCATION TO BE COORDINATED AROUND EQUIPMENT AND WITH <br />OWNER PRIOR TO INSTALLATION - SEE ELECTRICAL DRAWINGS <br />22 MOUNT LIGHT FIXTURES IN TUNNEL AS HIGH AS POSSIBLE - TYP. <br />K� • <br />1. CONFIRM EXACT LOCATION AND REQUIREMENTS WITH OWNER'S <br />SIGNAGE SUPPLIER PRIOR TO ROUGH -IN. <br />2. GENERAL CONTRACTOR TO NOTIFY ARCHITECT OF ANY <br />DISCREPANCIES PRIOR TO COMMENCING WITH ANY WORK. <br />3. SEE ELECTRICAL DRAWINGS, FOR ALL LIGHT FIXTURES <br />SPECIFICATIONS. <br />4. ALL STRUCTURAL STEEL, JOISTS, METAL DECK AND CEILING CHANNEL <br />FRAMING WITHIN THE CAR WASH AREA SHALL HAVE A <br />RUST -PROHIBITIVE PAINT AND THE STANDARD SHOP PRIMER SHALL <br />NOT BE VISIBLE - TYPICAL. <br />5. REFER TO SONNY'S CAR WASH DRAWINGS FOR ADDITIONAL <br />INFORI IATION. <br />6. HEIGHTS IN THE CARWASH TUNNEL ARE TAKEN FROM FINISHED FLOOR <br />0'-0" - TYPICAL U.N.O. <br />ELECTED CE IL INCH LEGEND <br />METAL sruc FasrErtirG NOTES 0 <br />I. ALL METAL FRAMING FOR CEMENT PLASTER CEILING SHALL BE 25 <br />GAUGE TYPICAL (UN.O.) <br />2. METAL STUDS SHALL BE CONNECTED TO STRUCTURAL STEEL WITH <br />(3) 0.1454 RAMSET POWER DRIVEN FASTENERS <br />3. METAL STUDS / CLIP ANGLE SHALL BE CONNECTED TO METAL <br />STUDS WITH MIN (4) 012-14 TEK SCREWS <br />4. CONTINUOUS TRACK SHALL BE CONNECTED TO STRUCTURAL <br />STEEL WITH (2) 0,145" # RAMSET POWDER DRIVEN FASTENERS AT <br />16" O.C. <br />5, CONTINUOUS TRACK / STUDS / CLIP ANGLES SHALL BE <br />CONNECTED TO CONC. / CMU WITH (2) 1/4"o x 1 1/4" TAPCON <br />FASTENERS AT 24" O.C. <br />6. CONNECT METAL STUDS / CLIP ANGLES TO WOOD TRUSSES WITH <br />(4) 1/4"4 WOOD SCREWS <br />1. CONNECT SHEATHING TO METAL STUDS WITH 012-14 TEK SCREWS AT <br />6" O.C. <br />8. CONTINUOUS TRACK SHALL BE CONNECTED TO ROOF DECK WITH <br />(2) 010 TEK SCREWS AT 24" O.G. <br />9. AS REQUIRED, THE CONTRACTOR SHALL PROVIDE CLIP ANGLES <br />FOR ALL METAL STUDS SO PROPER ALIGNMENT CAN BE <br />ATTAINED - CLIP ANGLES SHALL MATCH OR EXCEED THE STUD <br />GAUGE <br />2' x 2' SUSPENDED CEILING GRID SYSTEM WITH 2' x 2' <br />LAY -IN ACOUSTICAL CEILING TILES <br />METAL DECK WITH PLYWOOD SHEATHING AT TOWERS - <br />SEE WALL SECTIONS <br />CEMENT PLASTER CEILING (SMOOTH FINISH) <br />SUSPENDED CEILING PANELS - PROVIDED AND <br />INSTALLED BY SONNY'S CAR WASH VENDOR <br />2' x 4' FLUORESCENT LIGHT FIXTURE, LAY IN AT <br />SUSPENDED CEILING GRID SYSTEM - SEE ELECTRICAL <br />FOR MORE INFORMATION <br />RECESSED CAN DOWN LIGHT FIXTURE - SEE <br />ELECTRICAL FOR MORE INFORMATION <br />WALL MATED LIGHT FIXTURE - SEE ELECTRICAL FOR <br />MORE INFORMATION <br />4' DUAL TUBE FLUORESCENT LIGHT, SURFACE MOUNTED - <br />SEE ELECTRICAL FOR MORE INFORMATION <br />EXIT LIGHT FIXTURE - SEE ELECTRICAL FOR MORE <br />INFORMATION <br />FLOOD LIGHT - NOT USED <br />® <br />EXHAUST FAN - SEE MECHANICAL FOR MORE <br />INFORMATION <br />MECHANICAL SUPPLY REGISTER - SEE MECHANICAL <br />FOR MORE INFORMATION <br />MECHANICAL RETURN REGISTER - SEE MECHANICAL <br />I I <br />FOR MORE INFORMATION <br />04 <br />SECURITY CAMERA - SEE ELECTRICAL DRAWINGS <br />2'XV ACCESS PANEL - GC TO COORDINATE ACCESS <br />,<L� <br />PANEL WITH ALL FRAMING / MTL DECK ABOVE - TYP. <br />1�I ELECTED CE IL INCs PLAN <br />SCALE: 3/16" m r-0" <br />REVISIONS <br />III <br />BY <br />00 <br />CO <br />Cn <br />w <br />o ti <br />; ro <br />0 <br />�tl <br />°' oo 3 <br />� o <br />zm <br />e s ya <br />�fYi <br />gg <br />'sag <br />5 <br />O�v <br />'COD <br />�LL::� ; l o <br />(D <br />N <br />ri! <br />O O <br />n <br />.-7 <br />il. 0 a <br />V' <br />O Z <br />Y— <br />Q M <br />4- <br />S C <br />m C <br />C.a N v <br />c <br />O <br />Z > L v <br />m a <br />>y 0 d N <br />Q <br />m <br />Z <br />Date: 08. 25. 21 <br />Scale: AS NOTED <br />Project Mgr: AC <br />Drawn: MS <br />Job: 21-082 <br />Sheet <br />A2 <br />