My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7631 Gall Blvd (20)
Zephyrhills
>
Building Department
>
Building Plans
>
7631 Gall Blvd (20)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:37:34 AM
Creation date
2/25/2025 4:17:16 PM
Metadata
Fields
Template:
Building Plans
Street #
7631
Location
Gall Blvd
Contractor
Cal Development Inc
Building Plans - Permit #
15304
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7 }- <br />N TS <br />EXTERIOR WALL <br />1/2" WIDE MOUTH <br />TOP BEAM CLAMP <br />ATTACHED WITHIN <br />3" OF JOIST GIRDER <br />PANEL POINT <br />SUPPLY MAIN <br />3"MAX <br />U-BOLT STYLE STRAP <br />RESTRAINED WITH MINIMUM <br />3/8" FENDER WASHER, <br />LOCK WASHER, AND NUTS <br />JOIST GIRDER <br />TRUSS GIRDER <br />GROCERY <br />STORAGE <br />1/2" TOP BEAM CLAMP ATTACHED <br />WITHIN 3" OF PANEL POINT <br />ROOF DECK <br />1/2" ALL THREAD ROD <br />1/2" FENDER WASHER AND NUT <br />ON TOP AND BOTTOM OF ANGLE <br />TYP <br />FOR 8" MAIN USE 4 x 4 x 1 /4 <br />ANGLE DRILLED WITH MAXIMUM <br />9/16" HOLES (MAXIMUM 6 FT <br />SPAN ALLOWED) INSTALL ON <br />EVERY JOIST OR MAXIMUM 10'-0" <br />SPACING. <br />FOR 6" MAIN USE 3 x 3 x 5/16 <br />ANGLE DRILLED WITH MAXIMUM <br />9/16" HOLES (MAXIMUM 6 FT <br />SPAN ALLOWED) INSTALL ON <br />EVERY JOIST OR MAXIMUM 10'-0" <br />SPACING. <br />FOR 4" MAIN USE 3 x 2 x 1 /4 <br />ANGLE DRILLED WITH MAXIMUM <br />7/16" HOLES (MAXIMUM 6 FT <br />SPAN ALLOWED) INSTALL ON <br />EVERY OTHER JOIST OR MAXIMUM <br />12'-0" SPACING. <br />'IPE SUPPORT <br />10.30.07 F30 <br />ROOF JOISTS <br />DROP FROM <br />OVERHEAD <br />PIPING <br />LIGHTS <br />CONDENSER <br />DRY CONCEALED <br />PENDENT SPRINKLER <br />FREEZER/COOLER <br />EZER SECTION <br />NTS 10.30.07 F27-1 <br />1" PLUG <br />UPRIGHT — <br />SPRINKLER <br />SALES <br />NOTE: COORDINATE <br />EXACT LOCATION OF <br />SPRINKLERS AT <br />COOLERS/FREEZERS <br />WITH LIGHTS, <br />EVAPORATORS AND <br />OTHER <br />OBSTRUCTIONS. <br />NOTE THAT FINAL <br />LIGHT AND <br />EVAPORATOR <br />LOCATIONS MAY <br />DIFFER FROM THOSE <br />6J NTS <br />w <br />z <br />0 <br />N <br />SPRINKLER MAIN <br />1" SHOULDER NIPPLE <br />1" GLOBE VALVE <br />CHAIN -HUNG SIGNAGE <br />MUST BE VISIBLE AT ALL <br />AREAS <br />CONTRACTOR TO PROVIDE COVERAGE <br />BELOW ALL RTU DROP BOXES WHICH <br />EXCEED 4 FT IN WIDTH. <br />APROXIMATELY 10. REF 1-FP1 <br />2" BRANCH LINE TYI <br />CONNECT TO EXISTI� <br />2" BRANCH LINE TY <br />PIPE HANGE <br />MINIMUM 1" <br />SUPPLY TO <br />SPRINKLERS <br />SUPPLY AND RETURN AIR <br />PLENUMS FROM ROOFTOP <br />UNIT <br />ROOF DECK <br />JOIST <br />LE COUPLING <br />r�II r\�_r\ i v ivimTCH <br />SPRINKLER TYPE AT ROOF DECK <br />RTU SPRINKLER DROP <br />10.30.07 F25 NTS <br />PATCH PROCEDURE <br />1. ATTACH FIRMLY (WITH SHEET METAL SCREWS OR EQUIVALENT) A PIECE OF <br />KYSOR COOLER/FREEZER METAL SKIN, SHEET METAL OR EQUIVALENT MATERIAL <br />SIZED SLIGHTLY LARGER THAN THE HOLE TO BE PATCHED TO THE INSIDE OF <br />THE COOLER/FREEZER. <br />2. FROM THE TOP OF THE COOLER/FREEZER, FILL HOLE(S) TO BE PATCHED <br />COMPLETELY WITH THE EXPANSION FOAM. ALLOW THE FOAM TO COMPLETELY <br />DRY. <br />3. TRIM OFF EXCESS FOAM FLUSH WITH TOP OF COOLER/FREEZER. <br />4. ATTACH FIRMLY (WITH SHEET METAL SCREWS OR EQUIVALENT) A PIECE OF <br />KYSOR COOLER/FREEZER METAL SKIN, SHEET METAL OR EQUIVALENT MATERIAL <br />SIZED SLIGHTLY LARGER THAN THE HOLE, THAT IS NOW FILLED WITH THE <br />EXPANDED FOAM, TO THE OUTSIDE/TOP OF THE COOLER/FREEZER. <br />EXPANSION FOAM <br />SHEET METAL <br />SCREWS <br />COOLER/FREEZER SPRINK <br />NTS <br />SHEET METAL OR <br />COOLER/FREEZER PANEL SKIN <br />FREEZER/COOLER <br />ROOF (EXISTING) <br />FREEZER/COOLER <br />CEILING (EXISTING) <br />SHEET METAL OR <br />COOLER/FREEZER PANEL SKIN <br />LER PENETR <br />10.30.07 <br />ATION PATCH <br />MF19b <br />F21 <br />HANG 4 AND 6 INCH PIPE WITHIN 3 INCHES OF PANEL POINT <br />PIPE 3 INCH AND SMALLER NOT REQUIRED TO BE WITHIN 3 <br />INCHES OF PANEL POINT <br />FOR 6 AND 8 INCH PIPE, USE THRU BOLT CONNECTION <br />WHERE POSSIBLE. USE TRAPEZE HANGER WHERE <br />JOIST PANEL POINTS TYP ZZ JOIST WEB CONFLICTS WITH THRU BOLT <br />6„ <br />\ MAXI 1 TYP <br />6 INCH AND SMALLER PIPE <br />» <br />`—MAINTAIN VISIBLE CLEARANCE BETWEEN <br />PIPE AND JOIST MEMBERS TYP <br />4, 6 AND 8 INCH PIPE 8 INCH PIPE <br />_j <br />MAXIMUM HANGER SPACING FOR PIPING PERPENDICULAR TO JOISTS <br />BEAM CLAMP <br />THRU—BOLT <br />BEAM CLAMP <br />NOT TRAPEZED <br />NOT TRAPEZED <br />TRAPEZED <br />4" PIPE EVERY 12'-0" <br />4" PIPE EVERY 12'-0" <br />4" PIPE <br />EVERY OTHER JOIST <br />EVERY OTHER JOIST <br />NOT NECESSARY <br />6" PIPE EVERY 6'-0" <br />6" PIPE EVERY 12'-0" <br />6" PIPE <br />EVERY JOIST <br />EVERY OTHER JOIST <br />NOT NECESSARY <br />8 PIPE <br />8 PIPE EVERY 6'-0" <br />8 PIPE EVERY 6'-0" <br />NOT ALLOWED <br />EVERY JOIST <br />EVERY JOIST <br />PIPE RUNNING PERPENDICULAR TO JOISTS <br />6" <br />1/4"x2"x2" SQUARE WASHER & HEX NUT THRU BOLT TYP MAX <br />1/2" ALL THREAD ROD <br />I <br />FENDER WASHER & HEX NUT <br />� I <br />3.5" X 2.5" X .25" ANGLE _ <br />TRAPEZE REQ'D FOR 6" MAINS <br />4" X 4" X .25" ANGLE <br />TRAPEZE REQ'D FOR 8" MAINS TOP CHORD OF JOIST TYP <br />f, <br />ONE OPEN JOIST BAY <br />MINIMUM BETWEEN <br />TRAPEZE HANGERS <br />12" DO NOT HANG 2 OR MORE <br />MIN11 MAINS 4" OR LARGER BETWEEN <br />THE SAME JOIST SPACE <br />MAXIMUM HANGER SPACING FOR PIPES PARALLEL TO JOISTS <br />4" PIPE EVERY 12'-0" <br />6" PIPE EVERY 12'-0" <br />8" PIPE EVERY 12'-0" <br />NOT TRAPEZED <br />TRAPEZED <br />TRAPEZED <br />BEAM CLAMP <br />THRU BOLT <br />THRU BOLT <br />PIPE RUNNING PARALLEL TO JOIST <br />CONTRACTOR MAY SUBSTITUTE ANGLE IRON TRAPEZE <br />MEMBER WITH PIPE MEMBER. SIZE PIPE MEMBER IN <br />ACCORDANCE WITH NFPA-13 AND MAINTAIN 12 INCH <br />MAXIMUM DEFLECTOR DISTANCE <br />12" <br />MIN <br />UTILIZE THESE HANGING METHODS FOR ALL SPRINKLER <br />PIPING. SPACE TRAPEZE HANGERS IN ACCORDANCE <br />WITH SCHEDULE. LOCATE HANGERS WITHIN 3 INCHES <br />OF JOIST PANEL POINTS U.N.O. <br />NOTE: DO NOT SUPPORT SPRINKLER PIPING FROM BOTTOM CHORD OF BAR JOISTS <br />PIPE SUPPORT <br />4 NTS 10.30.07 F02-1 <br />OPTION "A" INSTALLATION PROCEDURE <br />1. CORE DRILL 2 1/2" DIAMETER HOLE IN THE FREEZER/COOLER INSULATED <br />CEILING PANEL. LOCATE HOLE AND REQUIRED SPRINKLER PROTECTION <br />IN ACCORDANCE WITH NFPA 13 OBSTRUCTION CRITERIA (SSP TYPE <br />SPRINKLERS). MAINTAIN 6" CLEARANCE FROM COOLER SEAMS. <br />2. INSTALL DRY PENDENT SPRINKLER PER MANUFACTURERS INSTALLATION <br />REQUIREMENTS. <br />3. COMPLETELY FILL ANNULAR CEILING OPENING BETWEEN THE ESCUTCHEON AND <br />TOP OF CEILING PANEL WITH OPEN -CELL POLYETHYLENE FOAM BACKER ROD. <br />EXPANDED FOAM IS NOT PERMITTED. <br />4. INJECT DOW CORNING 739 PLASTIC ADHESIVE SEALANT INTO AND AROUND <br />THE TOP OF THE FREEZER/COOLER CEILING CORE OPENING IN ACCORDANCE <br />WITH SEALANT MANUFACTURERS INSTRUCTIONS <br />OPTION "6" INSTALLATION PROCEDURE <br />1. CORE DRILL 2 1/2" DIAMETER HOLE IN THE FREEZER/COOLER INSULATED <br />CEILING PANEL FROM BELOW. LOCATE HOLE AND REQUIRED SPRINKLER <br />PROTECTION IN ACCORDANCE WITH NFPA 13 OBSTRUCTION CRITERIA (SSP <br />TYPE SPRINKLERS). MAINTAIN 6" CLEARANCE FROM COOLER SEAMS. <br />2. INSTALL TYCO DRY PENDENT SPRINKLER PER MANUFACTURERS INSTALLATION <br />REQUIREMENTS. INSERT BOOT PRIOR TO MAKE—UP WITH PIPING. <br />3. COMPLETELY SEAL INTERFACE BETWEEN BOOT FLANGE AND TOP OF <br />FREEZER/COOLER PANEL WITH ADHESIVE PROVIDED WITH BOOT IN <br />ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. <br />4. APPLY STRAP TIES ON BOOT AROUND DRY SPRINKLER BARREL PER <br />MANUFACTURERS INSTRUCTIONS. <br />1" DRY <br />SPRINKLER DROP <br />L FREEZER/COOLER <br />CEILING <br />SUPPLY FROM WET <br />PIPE SPRINKLER SYSTEM <br />TEE WITH PLUG <br />2 NYLON STRAP TIES N <br />(INSTALL OPPOSITE DIRECTIONS) <br />TYCO RUBBER SEAL io <br />BOOT MODEL DSB-2 z_ w <br />-SEALANT PER BOOT J <br />c� <br />MANUFACTURER z <br />V) <br />0 <br />z <br />SPRINKLER CUP TYCO MODEL TY3555 <br />CONCEALED 2007 DRY <br />COVER PLATE PENDENT SPRINKLER <br />2 CONCEALED 2007 DRY 2 (NO SUBSTITUTIONS) <br />PENDENT SPRINKLER <br />OPTION A (NO SUBSTITUTIONS) OPTION B <br />NOTE: CONTRACTOR TO SEAL DRY PENDENT SPRINKLERS AT FREEZER/COOLER USING ONE OF THE OPTIONS ABOVE. NO OTHER SEALANTS ARE PERMITTED. <br />FREEZER COOLER DRY PENDENT SPRINKLER <br />NTS <br />01.28.11 <br />F19 <br />r <br />w <br />D <br />w <br />w- <br />0 <br />z <br />0 <br />g <br />D <br />a <br />M� <br />I <br />iF ZtK U> <br />iLL1111DPI 98iW <br />U' PLLN�O *5'0 <br />1a�s 8y0 �.U;pwcOa3 <br />Xo 39.1h r��� <br />zm <br />ON o <br />S P_ <br />WW ��^ <br />Z <br />� <br />C6 � � O N <br />W.z � s <br />¢ =W �=^ 44� <br />J r en LL <br />co d <br />z <br />0 <br />0 <br />0 O <br />J <br />w <br />i0 <br />0 0 <br />Lu <br />♦^ <br />v! <br />z <br />w <br />o <br />o <br />Z <br />� <br />n/ <br />LL <br />W <br />0 <br />0 <br />W <br />9 <br />N <br />W <br />m <br />2 <br />D <br />z <br />m <br />0 <br />ISSUE BLOCK <br />CHECKED BY: <br />SRD/JEC <br />DRAWN BY: <br />OAF <br />PROTO: <br />192 SC <br />PROTO CYCLE: <br />122013 <br />DOCUMENT DATE: <br />01/30/14 <br />DARRELL E. STEIN <br />LICENSE # 58463 <br />i76TATEF)R <br />FIRE <br />PROTECTION <br />DETAILS <br />z <br />w <br />w <br />J <br />J <br />w <br />0 <br />FP3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.