My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7631 Gall Blvd (21)
Zephyrhills
>
Building Department
>
Building Plans
>
7631 Gall Blvd (21)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 9:43:28 AM
Creation date
2/25/2025 4:19:13 PM
Metadata
Fields
Template:
Building Plans
Street #
7631
Location
Gall Blvd
Contractor
AAA Plumb and Septic
Building Plans - Permit #
3261
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- � _►-. ��_'-- -� � �- _��;1�.�:-_ -• - - - =mil �:- .:.� 1L 1 .l L�11L1 ��. <br />NOTE: HANGERS MUST NOT DEFORM DUCT SHAPE. HANG PER LOCAL SEISMIC REGULATIONS <br />1 /4" NEOPRENE VIBRATION <br />ISOLATOR <br />NOTES: <br />1. EXHAUST FAN INSTALLATION TO <br />CONFORM TO NFPA 96. <br />2. ELECTRICAL WHIP TO BE A MINIMUM <br />OF 5'-0" LONG. <br />3. ALL EXHAUST FANS TO BE <br />MOUNTED LEVEL. PROVIDE SLOPED <br />CURBS WHERE FANS ARE <br />INSTALLED ON PITCHED ROOFS. <br />4. VERIFY ACTUAL PITCH. <br />GREASE DRAIN <br />Z <br />COVERED GREASE <br />COLLECTOR BY M.C. <br />INSULATED PREFABRICATED <br />CURB BY M.C. <br />HANGER RODS, <br />WIRES OR <br />STRAPS (TYP.) — <br />SUPPLY/RETURN <br />ACOUSTICAL DUCT <br />INSULATION <br />(RETURN DUCT <br />ONLY) <br />BAND: 1/2-ROUND MAY BE <br />LOCK NUT USED IF DUCT SHAPE IS <br />MAINTAINED <br />9 DUCT SUPPORT DETAIL <br />M4.01 SCALE: NO SCALE <br />FLASHING BY G.C. <br />Z <br />FE <br />N <br />UPBLAST KITCHEN HOOD <br />EXHAUST FAN WITH <br />RESTRAINING CABLE <br />CURB CAP BY FAN MFGR. <br />FASTENED TO NAILER <br />W/STAINLESS STEEL SCREWS <br />COUNTER FLASHING BY M.C. <br />PROVIDE HURRICANE <br />STRAPPING FOR ROOF <br />MOUNTED EQUIPMENT AS <br />REQUIRED LOCAL CODES. <br />FINISHED ROOF - VERIFY <br />ACTUAL ROOF CONSTRUCTION <br />SECURE CURB DIRECTLY TO <br />ROOF DECK <br />30007 INSULATION CONTINUOUS <br />6 GREASE EXHAUST FAN DETAIL LIQUID TIGHT WELDED STEEL <br />M4.0 SCALE: NO SCALE EXHAUST DUCT <br />T.G.C. SHALL INSTALL 3M FIRE <br />BARRIER GREASE DUCT WRAP, <br />MODEL 615A+ (ASTM E 2336 <br />AND ICC SC ESR-1255) AT <br />ROOF PENETRATION. <br />16 GA. W <br />EXIST'G F <br />REMAIN. <br />1" NON—COMBU' <br />1" NON COMBUSTIBLE SPACER <br />(STACKED WASHERS, PIPE, <br />TUBING, CONDUIT, ETC.) c <br />NAIL OR SCREW <br />ANCHOR------� <br />—22 GAUGE SHEETMETAL <br />—WIRE MESH <br />—1" MINERAL WOOL BATTS <br />PLAN SECTION <br />NOT TO SCALE. <br />SIDE SECTION <br />3 GREASE DUCT INSULATION DETAIL <br />M4.0 I SCALE: NO SCALE <br />3M FIRE BARRIER <br />DUCT WRAP. <br />OVERLAP WRAP PER <br />MANUFACTURER'S <br />INSTRUCTIONS <br />16 GA. WELDED <br />STL. DUCT <br />1" <br />NON-COMBUSTIBLE <br />SPACERS <br />22 GAUGE <br />SHEETMETAL <br />WIRE MESH <br />1" MINERAL <br />WOOL BATTS <br />DUCT INSULATION <br />QUADRANT <br />" FOR DUCTS UP <br />TO 18" <br />Y2" FOR DUCTS 19" <br />THRU 48" 7 <br />0 <br />0 <br />0 <br />1 0 <br />0 <br />ARM <br />8 BALANCING DAMPER DETAIL 1/8" PLATE T FOR DUCTSFOR DUCTS 9" AND UP TO'UP <br />M4.01 SCALE: NO SCALE <br />1 /4" ALL -THREAD ROD 2"x2"x1 /4" ANGLE IRON <br />ROOF DECK FLEX DUCT HANGER 2" WIDE <br />-� METAL STRAP. 24 GA. <br />44' MAX <br />SUSPENDED CEILING <br />STRUCTURE BEYOND SHEET METAL <br />SCREW MIN. Oel <br />(BAR JOIST, TRUSS, 4 PER BOOT <br />ETC.) <br />MAINTAIN FLEX DUCT STRAIGHT AND <br />TIGHT TO AVOID SAGGING (CUT ALL <br />EXCESS DUCT) 5'-0" MAX. LENGTH <br />ALL FLEX DUCT SHALL BE ABOVE <br />CEILING. <br />5 SUPPORT DETAIL FOR DUCT RUNS <br />M4.01 SCALE: NO SCALE <br />FLEXIBLE DUCT <br />--SHEET METAL DRAW BAND <br />\DIFFUSER BOOT <br />CETMG DIFFUSER <br />1. SET ROOF CURB ON STRUCTURAL STEEL - <br />SHIM DEAD LEVEL. SECURE ROOF CURB TO <br />METAL DECK AND A/C UNIT TO ROOF <br />CURB. <br />2. TRANSITION TO CONNECTION SIZES IN <br />DUCT RISE, REFER TO PLANS FOR SIZES. <br />3. 1" ACOUSTIC LINING IN SUPPLY AND <br />RETURN DUCTS FROM FAN DISCHARGE TO <br />POINT INDICATED ON MECHANICAL <br />DRAWINGS (10'-0" MIN.). DUCT SIZES <br />INDICATED ON PLAN ARE INTERIOR AND DO <br />NOT INCLUDE LINING. PAINT DUCTWORK TO <br />MATCH CEILING. REFER TO ARCHITECTURAL <br />DRAWINGS FOR COLOR SCHEME. <br />4. THE MECHANICAL ENGINEER DOES NOT <br />PROVIDE STRUCTURAL ENGINEERING <br />C - <br />SERVICES, AND RECOMMENDS TO THE <br />OWNER THAT ANY ADDITIONS LOAD <br />PLACED ON THE ROOF BE APPROVED BY A <br />O <br />STRUCTURAL ENGINEER. <br />O 2 <br />Li F <br />5. INSULATED ROOF CURB. PROVIDE MINIMUM <br />OF 14" HIGH RTU CURBS. CURB MUST BE <br />5 6 <br />PLACED ON THE STRUCTURAL FRAMING. <br />6 <br />6. FLEXIBLE CONNECTION - TYPICAL. <br />3 <br />TO NEAREST —`-"" <br />7. 2-POSITION (OPEN/CLOSED) OPPOSED <br />FLOOR SINK <br />BLADE BACKDRAFT DAMPER. DAMPER TO <br />OPEN WHEN UNIT IS RUNNING AND CLOSE <br />PROVIDE HURRICANE <br />WHEN UNIT SHUTS OFF. ACUATOR SHALL <br />FAIL CLOSED. <br />STRAPPING FOR ROOF <br />MOUNTED EQUIPMENT AS <br />8. RTU CONDENSATE DRAIN LINES SHALL NOT <br />REQUIRED LOCAL CODES. <br />BE LOCATED ON THE ROOF SURFACE; <br />ROUTE INTERNALLY IN THE JOIST SPACE, <br />TIGHT BELOW THE ROOF DECK TO AN <br />2 ROOF -TOP UNIT DETAIL APPROVED DRAIN LOCATION. PROVIDE <br />FACTORY CONDENSATE TRAPS. DO NOT <br />M4.0 SCALE: NO SCALE PENETRATE RTU CURBS WHEN ROUTING <br />LINES TO THE INTERIOR SPACE. <br />NOTE: <br />IN GENERAL, ELBOWS TO HAVE FULL TURNING RADIUS (R=A). <br />WHERE "R" IS LESS THAN "A" BUT NOT LESS THAN 1/3"A", <br />USE ONE VANE SPACED AS SHOWN. WHERE "R" IS LESS <br />THAN 1 /3"A", USE TWO VANES SPACED AS SHOWN. MINIMUM <br />RADIUS (R) = 4 INCHES. <br />NOTE: <br />1. AIRFOIL BLADES TO BE USED WHERE NORMAL <br />RADIUS ELBOW IS IMPRACTICAL & WHERE <br />ELBOW IS WITHIN 5 FT OF A BRANCH <br />TAKE -OFF OR BOOSTER HEATER (TO ASSURE <br />STRAIGHT FLOW). <br />2. USE TURNING VANES WHERE SUPPLY DUCT <br />AIRFLOW AT BEND EXCEEDES 1200 CFM. <br />16 <br />AC <br />15( <br />Er+cwEERn+e <br />& (^ CNISILTMG <br />SERVICES <br />Peter A. Leptuch, P.E. <br />300 N. Carroll Blvd. #200 <br />Denton, TX 76201 <br />(940) 735-5127 <br />7 � TURNING VANES <br />M4.0 SCALE: NO SCALE <br />20007 INSULATION CONTINUOUS <br />CUT OPENING LARGE ENOUGH <br />TO PERMIT THOROUGH <br />CLEANING. <br />16 GA BLACK STEEL DUCT, <br />CONTINUOUSLY WELDED <br />WELD STUDS TO DUCT SURFACE; <br />FASTENERS SHALL NOT <br />PENETRATE DUCT WALLS <br />NOT PLACE CLEANOUTS IN <br />(CATIONS THAT ARE DIFFICULT <br />ACCESS. <br />(INSTALL AT ALL CHANGE OF DIRECTIONS AND AT 12'-0" INTERVALS) <br />4 DUCT GREASE TRAP DETAIL (AS NEEDED) <br />M4.01 SCALE: NO SCALE <br />USE HORIZONTAL OFFSET <br />ONLY WHEN A DIRECT <br />VERTICAL RUN IS NOT <br />FEASIBLE. <br />INSULATED CLEANOUTS TO BE <br />PROVIDED IN ACCORDANCE WITH <br />ALL STATE AND LOCAL CODE <br />REQUIREMENTS. <br />VERTICAL SUPPORT ASSEMBLY. <br />SEE INSTALLATION MANUAL FOR <br />REQUIREMENTS. <br />SEE INSTALLATION <br />MANUAL <br />FOR MINIMUM OVERLAP <br />REQUIREMENTS. <br />EXHAUST FAN <br />FAN ADAPTER PLATE <br />WITH CERAMIC GASKET <br />J VENTED CURB PER <br />NFPA-96 <br />ADJUSTABLE DUCT <br />ADJUSTABLE COLLAR <br />V-CLAMP <br />STANDARD DUCT <br />Pow --,HORIZONTAL SUPPORT ASSEMBLY - <br />SEE INSTALLATION MANUAL FOR <br />REQUIREMENTS. <br />Am — <br />ADJUSTABLE DUCTS ARE USED ON RUNS <br />OVER 10OFT TO COMPENSATE FOR <br />THERMAL EXPANSION. SEE INSTALLATION <br />Lor <br />MANUAL FOR REQUIREMENTS. <br />RISER DUCT RUN SHOWN IS FOR EXAMPLE <br />PURPOSES ONLY. SEE MECHANICAL <br />PLANS FOR ADDITIONAL INFORMATION. <br />HOOD <br />ADDITIONAL INFORMATION INCLUDING <br />INSTALLATION MANUAL AVAILABLE <br />AT WWW.CAPTIVEAIRE.COM. <br />1 � TYPICAL GREASE DUCT RISER. <br />M4.01 SCALE: NO SCALE <br />StudiuRG_ <br />MAIN OFFICE: <br />1 HUNTINGTON QUADRANGLE <br />SUITE 2CO3 <br />MELVILLE, NY 11747 <br />P: 631.226-7700 F: 631.226.7175 <br />© Copyright 2018: RGBK, INC. <br />Seal: <br />Lan,dry <br />ARCHUCTUM PLANNING INTE iOR DESIGN <br />1202 Ridwrdsm Dr. #106 Tel:.2.14.631.6441 <br />Rchardsw, Texas 75080 Fax .214.634-1814 <br />t, <br />qq b <br />No 72679 <br />� IX <br />n 5-AT 0 Ott <br />A <br />Owner: <br />George Morkos <br />2520 Colony Reed Lane <br />Clearwater, FL33763 <br />It is the responsibility of the Construction <br />Manager/General Contractor and all <br />Sub -Contractors to verify all dimensions and <br />accept conditions of prior work by related <br />trades before proceeding with any work. <br />Date <br />07-22-2020 <br />Drawn By Check By <br />MRP TN <br />Scale <br />AS SHOWN <br />Issued: <br />Project Title <br />Charleys <br />Zephyrhills <br />WM706 <br />Project Address <br />7631 Gall Blvd, <br />Zephyrhills, FL 33541 <br />Project Number <br />WM706 <br />Drawing Title and Number <br />MECHANICAL <br />DETAILS <br />M4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.