Laserfiche WebLink
GENERAL POWER NOTES KEYNOTES <br />10 11 07.26.19 b <br />w - , <br />1. TELEPOWER POLE(S): MOUNT JUNCTION BOXES) TO <br />TOP SIDE OF BOTTOM CHORD OF BAR JOIST. INSTALL 16.131 CONNECT TO EXISTING CIRCUIT - <br />ELECTRICAL <br />r <br />o �Y o0 <br />ELECTRICAL DEVICES AND UNUSED FURNISHED POWER POLE AND TERMINATE WIRING 16.145 CONNECT CIRCUIT(S) TO EXISTING BRANCH c 0. w <br />— CIRCUITRY TO JUNCTION BOX. PROVIDE UNISTRUT SUPPORTS CIRCUITRY. MINIMUM WIRE SIZE AND <br />16.492 AND HARDWARE TO SECURE TELEPOWER POLE PANELBOARD CIRCUIT ARE NOTED. VERIFY S <br />PLUMB TO BUILDING STRUCTURE. REF POWER POLE SIZE, RATING AND CONDITION OF EXISTING0,� <br />ELECTRICAL REF 1 /E2 CONNECTION DETAIL. BRANCH CIRCUIT CONDUIT AND WIRE PRIOR �a <br />TO USE TO ENSURE THAT THEY MEET <br />CIRCUITRY — — — — — — 2. PROVIDE LIQUID -TIGHT FLEXIBLE METAL CONDUIT REQUIRED SIZE, AND ALL U.L. RATINGS AND <br />REF 5/RE1 AND WIRING FROM DISCONNECT SWITCH OR REPLACE AS REQUIRED. <br />JUNCTION BOX TO EQUIPMENT KNOCKOUT OR 16.201 EXTERIOR SIGN POWER: WHERE ELECTRICAL t4 w <br />ELECTRICAL CONNECTION POINT. CONNECTIONS FOR SIGNAGE OCCUR BELOW V Y <br />ROOF LINE, ROUTE POWER TO WALL AT SIGN <br />2 3. WHERE EQUIPMENT NAMEPLATE PROTECTIVE CONTROL BOX(ES). WHERE ELECTRICAL S <br />B - — DEVICE RATING DIFFERS FROM SIZE PROVIDED, CONNECTIONS FOR SIGNAGE OCCUR ABOVE V¢� <br />NOTIFY WALMART CONSTRUCTION MANAGER ROOF LINE, PROVIDE UNISTRUT TO MOUNT <br />— L — — — 16.489 IMMEDIATELY TO COORDINATE RESOLUTION. CONTROL <br />F PA <br />LOW VOLTAGE (WIR NOES) TOB FROM CONACK SIDE OTROL RAPET. <br />H — — — — — — — — — — 4. ELECTRONIC FIRE PROTECTION/SECURITY ALARM BOX(ES) TO SIGN PROVIDED AND INSTALLED m w o w o > <br />BOXES AND CONDUITS SHOWN ON POWER PLANS BY OTHERS. REFER TO ARCHITECTURAL w U- w Q = o a <br />SHALL BE PROVIDED UNDER THIS CONTRACT. IN DRAWINGS FOR EXACT SIGN LOCATION(S) ° _ w a LL = z <br />ADDITION, UNLESS NOTED OTHERWISE, THE PRIOR TO INSTALLATION. PROVIDE ONLY ONE w o = = o'If o Z ° o w <br />FOLLOWING GENERAL NOTES APPLY: PENETRATION THROUGH THE ROOF. REF a N � � ° z ° m o Z a <br />G R SALES_ POWER DEMO_ PLAN _ SALES FLOOR POWER DEMO PLAN A. ALL ALARM JUNCTION BOXES SHALL BE ARCHITECTURAL EXTERIOR WALL SECTIONS p Of m <br />LL aacn-��� oowF= <br />"4"X4"X2-1/8" MINIMUM. AND SIGN ATTACHMENT FOR ROOF AND 0 w ° <br />„ _ B. ALARM RACEWAYS SHALL BE 3/4" MINIMUM WITH PARAPET PENETRATION REQUIREMENTS. zp o 2 o = w w o <br />3 NTS 1 - 20-0 PULL WIRE AND INSULATING BUSHINGS AT END f- z Q , a z' <br />16.470 FURNISH AND INSTALL NEW 20 AMP, 120 VOLT Q - o ° w f w o z a <br />OF VERTICAL RACEWAY RUN. J awn z w z - w 0 � IY <br />C. VERTICAL RACEWAYS FROM ALARM BOXES CIRCUIT(S). FEED FROM PANELBOARD AS d o m w o m n m w W W Z w Z <br />INDICATED. PROVIDE 20A-1P CIRCUIT w w w a z o <br />SHALL BE EITHER CONCEALED INSIDE WALL OR Q z I_ - � � o o 0 a o ° <br />BREAKER IF NEEDED. E.C. SHALL MATCH � 0 0 0 5 E m a a w o a m <br />PANELBOARDS Ill Ill SURFACE MOUNTED (TO MATCH JUNCTION BOX MANUFACTURER, TYPE AND AIC RATINGS OF <br />L1D2, AND L1U LOCATED IN MOUNTING). ALL VERTICAL RUNS SHALL BE EXISTING CIRCUIT BREAKERS. <br />ELECTRICAL ROOM 1 TURNED 90-DEGREES AT TOP SIDE OF BOTTOM 16.489 RELOCATE, EXTEND, AND RECONNECT <br />CHORD OF BAR JOIST AND EXTENDED CIRCUITRY AND ELECTRICAL DEVICES FOR <br />HORIZONTALLY TO A LOCATION ACCESSIBLE BY RELOCATED AND/OR NEW EQUIPMENT. VERIFY <br />1 2 3 4 5 6 7 8 9 10 11 12 13 VERTICAL FLOOR TYPE LIFT. CONDITION OF BRANCH CIRCUITRY, CONDUIT <br />! <br />5. UPON COMPLETION OF ELECTRICAL INSTALLATION AND WIRE TO ENSURE THEY MEET ALL U.L. <br />AND PRIOR TO ENERGIZING CIRCUIT: RATINGS AND REPLACE AS REQUIRED. VERIFY <br />- — - — - — - — - — — - — - — - — FINAL LOCATION OF RELOCATED/NEW <br />---- _ - - - - - - - --- - _ � - - - - - -- - - - A. 1NSRE�Tfi/1/IRE ANf�CABLE��R-I3HYSICAL <br />6 DAMAGE. EQUIPMENT WITH WALMART CONSTRUCTION <br />I I E2.3 MANAGER PRIOR TO ROUGH -IN. <br />B. PERFORM CONTINUITY TEST. <br />- - C. VERIFY PROPER PHASING CONNECTION TO ALL <br />16.492 E.C. SHALL COORDINATE WITH GENERAL <br />THREE PHASE MOTOR LOADS. CONTRACTOR AND ARCHITECTURAL J <br />---�------------- <br />DEMOLITION PLANS THE EXTENT OF <br />I � ' ELECTRICAL DEMOLITION. REMOVE UNUSED z <br />- DEVICES, BOXES, CONDUITS, AND WIRING 0 <br />- RE1 14 15 BACK TO ORIGINATING JUNCTION BOXES OR <br />PANELBOARDS. REFERENCE POWER PLANS <br />II_ I FOR CIRCUITRY TO BE REUSED. DEMOLITION <br />I I <br />I ,i IL�I <br />l <br />� � � � SHALL NOT AFFECT ACTIVE CIRCUITS. IF m <br />CIRCUIT IS DEMOLISHED ALL THE WAY TO <br />PANELBOARDI I I REPLACE WITH <br />HREMOR PLATE. EUUP ATEIT KER AND <br />I I <br />y�� ��� ��� ��� 9�\1 � I I I TYPEWRITTEN CIRCUIT DIRECTORY O 0 � `-' <br />II IDENTIFYING CIRCUIT AS "SPACE". - c,� <br />1 - - ��_- - - p -_ - - -- -- -- - _ ---- - - - -_ - - - COORDINATE EXACT REQUIREMENTS WITH <br />— — - - --_ �w__��.L- - --- -- - - - — ---- --_ -- - - ---- - J <br />H - - <br />--- �_ -- - - - - -�--T , _•-_ I _- I 1 ' - ,' � J _ _.�_._ I EXISTING CONDITIONS PRIOR TO BID. � LL <br />- — - —!r - — - — - 1 I -� I _ I 16.507 MENU TV'S: MOUNT JUNCTION BOX AT •• _j <br />4 TYP OF 3 EXISTING BUSWAY BL1�1 1 ENVIRONMENTAL <br />STRUCTURE. AFTER INSTALLATION OF DROP J <br />I � POLE AND TV COMPONENT TRAY, EXTEND vJ = N O <br />E2.2 <br />2 1 J f 1 7 �_ ; CONDUCTORS III FLEXIBLE METAL CONDUIT, <br />1 1 O <br />i <br />�1 <br />- <br />��_� 2.2 <br />BL1B - 16 - COMPONENT ROUTED DTRAY. PROVIDE 120V 20A IOP POLE, TO TV o a <br />! <br />-- CONTRACTOR TO FURNISH AND INSTALL <br />GE2 - - i I - - I _ I DUPLEX RECEPTACLE ON TV COMPONENT O = LU o <br />3 I 1 +9'-0^ TRAY AND MAKE FINAL TERMINATIONS. N O o <br />E2 AND CIRCUIT BREAKER PLUG-IN UNITS - - 16.650 Z o <br />_ I -NEW STARLINE BUSWAY (IF APPLICABLE) � - I I � I - COORDINATE TV LOCATIONS WITH STORE N <br />I I <br />-__ _ S REQURED. _.._ -- - LU N <br />-_ _- 3/4"C SETUP SUPERVISOR. <br />_1 _ <br />CONTACT MEGREPS, 16.650 CONDUIT SLEEVE: PROVIDE 1-1/2" CONDUIT m O <br />- SLEEVE WITH BUSHINGS ABOVE BAR JOIST 0 F <br />I WS I' \ I I r_I I (UNLESS NOTED OTHERWISE). <br />(501) 821-6200 EX: 301 1 EXISTING BU <br />JON MATTHEWS OR RANDY MA J <br />E. <br />_ ;- T- WALMART@MEGRE - -- - I - - -rT <br />- - - - W <br />G - - - - - - - - - - - - 20'-6"co <br />�- <br />I ! M WHEEL BALANCER, I m <br />� <br />� CORD z <br />I co <br />TYP OF 2 TIRE CHANGER, <br />IH--4 - - - ---- -- I� 16.507 _...., ❑ ❑ ❑ ❑ IC11 CfI I I I PNEUMATIC I <br />I/ 3 ISSUE BLOCK <br />- 34,36 <br />j�I u IviI <br />s � � �I _». � ❑ ❑ � Lam, ❑ L2 D E 3 <br />- - -- »... __.......» - _.._. 16.145 1 ADD#1 01/27/21 <br />�� 120/208/1 2 ADD#3 02/26/21 <br />32 3 CCD#2 04/26/21 <br />Il, <br />4 CCD#3 05/11/21 <br />- - - - - - - - - - - - - - — _- 5 CCD#5 08/16/21 <br />H H - H h H _. m _ 10/04/21 <br />- -- I� <br />L-- - <br />-- - -- - <br />f r <br />I I _ -. <br />EXISTING PANEL BOARDS CH2F, <br />Cil IN COMPRESSOR HOUSE l� �) <br />-- <br />H_ H <br />I- I� - - I I -- _ I I I !! I I <br />E1-4 <br />_ - - - <br />CEZ�- CHECKED BY:CM <br />r 1 ---- - - <br />T I <br />~ lC� - {- _ J_�._. DRAWN BY: PT <br />L� - - - <br />-,. I� i PROTO CYCLE: 09/25/20 <br />C�J ;>�T�IT�� <br />DOCUMENT DATE: 11/06/20 <br />_.. L <br />- _ <br />_ 8 L4D2 LOCATEDD IN LECTRIC D I ! ❑ IH ICI ICE Ill l� CI ILJ 'J�1 __ �71 <br />AL ---- <br />E2.2 ROOM 4 -- - ❑ �- <br />1 <br />- — - — - <br />_ I I H I� <br />1J !J 1 ❑ I _ <br />`� <br />RE1 ,' i I i I �� <br />Iu' I �' IIcc--__,,�I��' I�'IImo�'' I`` _ _ ' Czx= <br />2 PROVIDE SQUARE-D ,`I - l L HI �1 l]l �I _I _ - - -�� -�-- �� <br />C - -- - -- Lj <br />#QOB330GF1, 30A-3P, GFI -- - - - - - - I -- <br />BREAKER MOUNTED IN A,\ j4 <br />SQUARE-D #Q0403L60NS, _ ;• �ti <br />i <br />NEMA 1 ENCLOSURE, REF 1-E4 <br />EXISTING PANELBOARD Lill � �'� 2 E2.3 8 � �I � � � I � 4 <br />AND NEW PANELBOARD LLQ-2°�� _ _ RE1 EVC1 o <br />-- <br />LOCATED IN LIQUOR P _ - <br />STOCKROOM I _ rT� L - -,— - - <br />ti <br />`�' - - _ <br />- -- , <br />I I <br />- -, 6 16.47o I 2 i���1 - <br />LP - 22 - <br />i <br />CI=_ <br />PANELBOARD L4D4 - r 16.507 "F 2 <br />\ GE2 I i <br />LOCATED IN BAKERY - — - — - — - I - - - 1 <br />1 _ I x� 1 , <br />- - - I I �� <br />I <br />2 -- I -II � I I - <br />\ GE2 - <br />' I <br />I <br />I <br />I = <br />B\ - — - — - — - — - - -� 3 <br />16.201 j E2.2 E2.2 EXISTING PANEL 10 11 9 i 1 •`�O G <br />6 5 <br />E2.2 E2.2 at \�.•'•�-� SF'•.�,p . <br />\ � j 1 E2.2 �-- PANELBOARDS H3B, H3P, ( I I I �,. � <br />\ \ REUSE EXISTING SIGNAGE CIRCUIT L3P 2. EXISTING PANEL L3U IN EQUIPMENT ROOM E2 2 1, L3D2, L3D3, L3P AND I , <br />' H A OCATED IN Ell =_ No 76917 '. <br />EXTEND CIRCUITRY AS REQUIRED TO NEW L4D3 IN MECHANICAL ROOM <br />CONNECTIONS. REUSE ALL CONTROLS <br />ASSOCIATED WITH THE CIRCUIT. <br />-- COURTESY - ,1 I I <br />S TE � ' TA O F <br />I I <br />CONTROL BOX PROVIDED BY SIGN INSTALLER DESK 5 (-`—,.. �T�.�� O R `O <br />PANELBOARD LTS3 LOCATED _ _ I -- �� S '••......••'• C?`��` <br />--�- SWITCH. VERIFYWITH TNOCATION WSTALLED STHOSIGNCT IN MONEY CENTER I " / = -' I E2.3 S/ONALE� <br />INSTALLER PRIOR TO INSTALLATION -- <br />1 <br />- 10/04/21 <br />CL <br />a. <br />A _ - - - _ _ - - - �)----_-_ _-_-_-_- - ---- - - - - - - - <br />w 16.131 2 <br />Ni --- - 16201 POWER PLAN <br />REUSE EXISTING SIGNAGE CIRCUIT L3P-2. <br />-�I ETR <br />Li EXTEND CIRCUITRY AS REQUIRED TO NEW <br />1 ,, CONNECTIONS..__ - - -_ --- - -- <br />REUSE ALL CONTROLS <br />� 2 ASSOCIATED WITH THE CIRCUIT. i� WP,WR, <br />GFI, +24" <br />a <br />w <br />N CONTROL BOX PROVIDED BY SIGN INSTALLER <br />WITH FACTORY INSTALLED DISCONNECT <br />SWITCH. VERIFY LOCATION WITH SIGN <br />INSTALLER PRIOR TO INSTALLATION �_'_ EXISTING CONDITIONS WERE TAKEN FROM EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING <br />8 ORIGINAL DRAWINGS AND MAY NOT REFLECT A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br />ENTIRE SHEET REVISED EXACT "AS -BUILT" CONDITIONS. CONTRACTOR SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE <br />SHALL FIELD VERIFY ALL EXISTING CONDITIONS TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES <br />a L POWER PLAN PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR NOT RELIEVE THE RESPONSIBILITY OF PERFORMING <br />M SHALL CAREFULLY COORDINATE NEW WORK AND THE WORK PROPERLY. NO ADDITIONAL SHEET: <br />1 - _- DEMOLITION WITH ALL OTHER DISCIPLINES AND COMPENSATION SHALL BE ALLOWED BECAUSE OF <br />1" = 20'-0" EXISTING CONDITIONS. CONDITIONS THAT OCCUR DUE TO FAILURE TO E 2 <br />oFAMILIARIZE WORKERS WITH THIS KNOWLEDGE. <br />U <br />