Laserfiche WebLink
SHEET NOTES <br />1. ALL ELECTRICAL WORK INCLUDING DATA AND <br />POWER DISCONNECTION BY GC. <br />2. REMOVAL OF POWER POLES AND <br />REINSTALLATION OF FLOOR POWER AND <br />DATA RACEWAYS BY GC. DATA LINES BY <br />OTHERS. <br />3. GENERAL CONTRACTOR RESPONSIBLE FOR <br />ALL ELECTRICAL AND PLUMBING WORK. <br />4. GC RESPONSIBLE FOR ANCHORING ALL <br />MILLWORK TO PREVENT OVERTURNING, <br />REFERENCE MILLWORKMANUFACTURERS <br />INSTRUCTIONS FOR CLEAT HEIGHTS. <br />5. CAULK ALL COUNTERS AND BACKSPLASHES <br />TO THE WALL. <br />6. ALL WOOD MATERIAL SHOWN IN DETAILS ON <br />THIS SHEET SHALL BE FIRE RETARDANT <br />TREATED WOOD (FRTW) IN ACCORDANCE <br />WITH INTERNATIONAL BUILDING CODE <br />SECTION 603.1. THIS INCLUDES ALL <br />REFERENCES TO "BLOCKING", "NAILERS", <br />"PLYWOOD", "SHEATING", AND IF APPLICABLE <br />"WOOD STUDS". <br />2'-1" <br />"SANTAMARGHERITA" <br />QUARTZ ISTRIA <br />COUNTERTOP AND <br />BACKSPLASH <br />CONTINUOUS SEALANT <br />OWNER FURNISHED GC <br />INSTALLED COUNTER AND <br />BACKSPLASH <br />OWNER FURNISHED GC <br />INSTALLED BASE CABINET <br />4" BASE RB5 <br />MILLWORK SECTION <br />(OWNER FURNISHED, <br />GC INSTALLED) <br />0 <br />fV <br />"SANTAMARGHERITA" <br />QUARTZ ISTRIA <br />COUNTERTOP AND <br />BACKSPLASH <br />CONTINUOUS SEALANT <br />OWNER FURNISHED GC <br />INSTALLED COUNTER AND <br />BACKSPLASH <br />OWNER FURNISHED GC <br />INSTALLED COUNTER <br />BRACKET PER <br />MANUFACTURERS <br />INSTRUCTIONS, SECURED <br />TO STUD <br />4" BASE RB5 <br />MILLWORK SECTION <br />(OWNER FURNISHED, <br />GC INSTALLED) <br />10'-0" <br />CEILING HEIGHT <br />x <br />INSTALL NEW WALL TRIM WITH <br />OFF GRID TEE ADAPTER AT NEW <br />FURRED WALL <br />NEW CEILING GRID AND <br />TILE PANELS <br />x MAINTAIN GAP BETWEEN NEW STUDS AND <br />EXISTING ACOUSTICAL GRID TO PREVENT <br />INTERFERENCE, CAREFULLY INSTALL NEW <br />WALL FINISHES TIGHT TO THE CEILING GRID <br />MAXIMUM 1/8" GAP. <br />`— SECURE NEW FURRED WALL TO <br />WALL TRACK AT EVERY STUD <br />SECURE NEW METAL STUD <br />TRACK TO EXISTING WALL <br />AT EVERY STUD <br />also NEW STUD WITH 1/2" GYPSUM <br />ON 1/2" PLYWOOD, FIELD VERIFY <br />FEATURE WALL DETAIL <br />1 1/2" = V-0" <br />CLEAT DIMENSIONS <br />FURNISHED ARE FOR <br />REFERENCE, CONFIRM <br />CLEAT MOUNTING <br />HEIGHTS WITH <br />MANUFACTURERS <br />INSTRUCTIONS <br />OWNER FURNISHED <br />GC INSTALLED <br />CLEATS, TYP OF (2) <br />OWNER <br />FURNISHED GC <br />INSTALLED UPPER <br />CABINET <br />MILLWORK SECTION <br />(OWNER FURNISHED, <br />GC INSTALLED) <br />EXISTING STUD WITH 1/2" <br />GYPSUM ON 1/2" PLYWOOD, <br />FIELD VERIFY <br />SECURE MILLWORK TO WALL PER <br />MANUFACTURERS INSTRUCTIONS <br />WITH CLIPS PROVIDED, BY GC <br />TO CONCRETE FLOOR <br />ALL WOOD MATERIAL SHOWN SHALL BE <br />FIRE RETARDANT TREATED WOOD <br />(FRTW) IN ACCORDANCE WITH <br />INTERNATIONAL BUILDING CODE <br />SECTION 603.1. <br />THIS INCLUDES ALL REFERENCES TO <br />"BLOCKING", "NAILERS", "PLYWOOD", <br />"SHEATHING", AND IF APPLICABLE <br />"WOOD STUDS". EXCLUDES MILLWORK <br />irlmW <br />), GC <br />,RK <br />!"GYPSUM <br />FIELD VERIFY <br />D WITH 1/2" <br />/2" PLYWOOD, <br />"SANTAMARGHERITA" <br />QUARTZ ISTRIA <br />COUNTERTOP AND <br />BACKSPLASH <br />CONTINUOUS SEALANT <br />OWNER FURNISHED <br />GC INSTALLED <br />COUNTER AND <br />BACKSPLASH <br />OWNER FURNISHED <br />`., GC INSTALLED SINK N <br />AND BASE CABINET <br />N SECURED TO STUDS, <br />FINAL CONNECT BY GC <br />KNEE AND TOE <br />CLEARANCE m <br />I 4" BASE <br />11" 6" <br />R65 <br />MILLWORK SECTION <br />(OWNER FURNISHED, <br />GC INSTALLED) <br />�N TOP OF SLAT WALL FIXTURE <br />H ADJACENT FRAME BOARDS. <br />AT DIMENSIONS FURNISHED <br />FOR REFERENCE, CONFIRM <br />AT MOUNTING HEIGHTS WITH <br />IUFACTURERS INSTRUCTIONS <br />WNER FURNISHED GC <br />ISTALLED SLAT WALL FIXTURE <br />WNER FURNISHED GC <br />ISTALLED CLEATS, TYP <br />F (3) <br />CLEAT DIMENSIONS <br />FURNISHED ARE FOR <br />REFERENCE, CONFIRM <br />CLEAT MOUNTING <br />HEIGHTS WITH <br />MANUFACTURERS <br />INSTRUCTIONS <br />4" BASE[*] <br />MILLWORK ACCESSORY SLAT WALL <br />(OWNER FURNISHED, <br />GC INSTALLED) <br />1" = 1'-0" <br />CLEAT DIMENSIONS <br />FURNISHED ARE FOR <br />REFERENCE, CONFIRM <br />CLEAT MOUNTING <br />HEIGHTS WITH <br />MANUFACTURERS <br />INSTRUCTIONS <br />OWNER FURNISHED <br />GC INSTALLED <br />CLEATS, TYP OF (2) <br />OWNER <br />FURNISHED GC <br />INSTALLED UPPER <br />CABINET <br />MILLWORK SECTION <br />(OWNER FURNISHED, <br />GC INSTALLED) <br />1 <br />SHEET WAS ADDED <br />TO THE DOCUMENT <br />wa- <br />U) <br />w <br />p>~OQOQ j1UuOFxQ <br />WxxLLa' V, Zw, oa <br />�a�wozo�xoQN§ <br />O <br />a U~Fa <br />oo=� <br />U- <br />w <br />� O Q fn fA <br />O <br />� <br />3Nwo Wi=w2,wf o <br />z�0m <br />zLL��aLL�oU��Z} <br />J <br />D <br />d Z W zU�Qlx} ww o <br />HmzWmWU�Wzo <br />0- <br />Ocr� �Z'�y <br />V(n<�U. 000 <br />20LL� <br />=F wirwz <br />Co <br />OUOOw (LZ <br />m <br />a <br />m <br />%49 <br />L <br />Lo <br />C4 C= cry <br />M <br />0 0 <br />� li w <br />r� <br />Cn J N <br />o <br />J�5 <br />cr <br />J = o <br />�- <br />ao <br />� <br />- <br />o <br />IIIN <br />�Jw <br />in 0 <br />W <br />to <br />N"' <br />ti <br />w <br />m <br />2 <br />D <br />z <br />in <br />O <br />ISSUE BLOCK <br />1 CCD1 03/29/21 <br />2 CCD4 06/21/21 <br />3 CCD6 10/04/21 <br />CHECKED BY: <br />RD <br />DRAWN BY: <br />MUMB <br />PROTO CYCLE: <br />09/25/20 <br />DOCUMENT DATE: <br />11/06/20 <br />10/05/21 <br />VISION <br />CENTER <br />DETAILS <br />1" = 1'-0" <br />1" = 1'-0" <br />1" = 1'-0" <br />SHEFT- <br />VC1.1 <br />