RESTROOM DOOR SYMBOLS
<br />ED 1/32"
<br />:RCASE
<br />ERING
<br />EIGHT OF LETTERING
<br />6" MIN. TO 2" MAX.
<br />CORRESPONDING
<br />CONTRACTED
<br />(GRADE 2) BRAILLE
<br />SIGNS & IDENTIFICATION
<br />1. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO IDENTIFY FACILITIES THAT ARE
<br />ACCESSIBLE TO AND USABLE BY PHYSICALLY DISABLED PERSONS AS SET FORTH IN TITLE III AND AS SPECIFICALLY
<br />REQUIRED IN THIS SECTION.
<br />2. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. THE
<br />BLUE SHALL BE EQUAL TO COLOR NO. 15090 IN FEDERAL STANDARD 595C.
<br />3. FOR CHARACTER PROPORTION, THE UPPERCASE LETTER "0" SHALL BE USED TO DETERMINE THE ALLOWABLE
<br />WIDTH OF ALL CHARACTERS OF A FONT. THE WIDTH OF THE UPPERCASE LETTER "0" OF THE FONT SHALL BE 55
<br />PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE UPPERCASE LETTER "I".
<br />4. MINIMUM CHARACTER HEIGHT SHALL COMPLY WITH 2O10 ADA TABLE 703.5.5. VIEWING DISTANCE SHALL BE
<br />MEASURED AS THE HORIZONTAL DISTANCE BETWEEN THE CHARACTER AND AN OBSTRUCTION PREVENTING
<br />FURTHER APPROACH TOWARDS THE SIGN. CHARACTER HEIGHT SHALL BE BASED ON THE UPPERCASE LETTER "I".
<br />CHARACTER HEIGHT MEASURED FROM THE BASELINE OF THE CHARACTER SHALL BE 5/8" (16 MM) MINIMUM AND 2
<br />INCHES (51 MM) MAXIMUM.
<br />5. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND.
<br />6. WHEN RAISED CHARACTERS OR SYMBOLS ARE USED, THEY SHALL CONFORM TO THE FOLLOWING:
<br />A. CHARACTERS SHALL BE RAISED 1/32" MINIMUM AND SHALL BE SANS -SERIF UPPERCASE CHARACTERS. RAISED
<br />LETTERS SHALL BE DUPLICATED IN BRAILLE.
<br />B. RAISED CHARACTERS SHALL BE A MINIMUM OF 5/8" HIGH AND 2" MAXIMUM BASED ON THE HEIGHT OF THE LETTER
<br />"I"
<br />C. PICTORIAL SYMBOL SIGNS (PICTOGRAMS) SHALL HAVE TEXT DESCRIPTORS LOCATED DIRECTLY BELOW THE
<br />PICTOGRAM FIELD. PICTOGRAMS SHALL HAVE A FIELD HEIGHT OF 6" MINIMUM. PICTOGRAMS AND THEIR FIELDS
<br />SHALL HAVE A NON -GLARE FINISH. PICTOGRAMS SHALL CONTRAST THEIR FIELDS, WITH EITHER A LIGHT
<br />PICTOGRAM ON A DARK FIELD OR A DARK PICTOGRAM ON A LIGHT FIELD.
<br />7. CONTRACTED (GRADE 2) BRAILLE SHALL BE USED WHEREVER BRAILLE IS REQUIRED. DOTS SHALL BE 0.090" (2.3 MM)
<br />TO 0.100" (2.5 MM) ON CENTER IN EACH CELL WITH 0.241" (6.1 MM) TO 0.300" (7.6 MM) SPACE BETWEEN
<br />CORRESPONDING DOTS IN ADJACENT CELLS. DOTS SHALL BE RAISED A MINIMUM OF 0.025" (0.6 MM) TO 0.037" (0.9
<br />MM) ABOVE THE BACKGROUND.
<br />8. WHEN PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, RAISED LETTERS SHALL BE
<br />ACCOMPANIED BY BRAILLE. TACTILE CHARACTERS ON SIGNS SHALL BE LOCATED 48 INCHES (1220 MM) MINIMUM
<br />ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED FROM THE BASE OF THE LOWEST TACTILE
<br />CHARACTER AND 60 INCHES (1525 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, MEASURED
<br />FROM THE BASELINE OF THE HIGHEST TACTILE CHARACTER. WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE
<br />SIGN SHALL BE LOCATED ALONGSIDE THE DOOR AT THE LATCH SIDE. WHERE A TACTILE SIGN IS PROVIDED AT
<br />DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHERE A TACTILE
<br />SIGN IS PROVIDED AT DOUBLE DOORS WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO THE RIGHT OF THE
<br />RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE AT THE LATCH SIDE OF A SINGLE DOOR OR AT THE RIGHT
<br />SIDE OF DOUBLE DOORS, SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT WALL. SIGNS CONTAINING TACTILE
<br />CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18 INCHES (455 MM) MINIMUM BY 18 INCHES
<br />(455 MM) MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING
<br />BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION. EXCEPTION: SIGNS WITH TACTILE CHARACTERS
<br />SHALL BE PERMITTED ON THE PUSH SIDE OF DOORS WITH CLOSERS AND WITHOUT HOLD -OPEN DEVICES.
<br />9. SIGNS TO BE PROVIDED AT ALL PUBLIC MEN, WOMEN, FAMILY AND UNISEX RESTROOMS. ROOM NAME SHALL BE
<br />"RESTROOM" AT UNISEX TOILETS.
<br />I•�
<br />M
<br />C)
<br />Cn
<br />a
<br />U)
<br />0
<br />A
<br />SYMBOLS LEGEND
<br />X_XX
<br />REFERENCE AT KEYNOTE INDICATOR
<br />10.1
<br />KEYNOTE INDICATOR
<br />A KEYNOTE OR BLOCK OF
<br />X•XX
<br />KEYNOTES WITH A LEADER
<br />X.XX
<br />ATTACHED APPLY SPECIFICALLY
<br />X.XX
<br />TO THE ITEM, AREA, OR SURFACE
<br />TO WHICH THE LEADER IS
<br />POINTING
<br />SALES
<br />100
<br />IN ADDITION TO THE ROOM FINISH
<br />SCHEDULE, A KEYNOTE OR BLOCK
<br />X.XX X.XX
<br />OF KEYNOTES ATTACHED TO THE
<br />X.XX X.XX
<br />ROOM NAME TAG APPLY TO THE
<br />X.XX X.XX
<br />ENTIRE ROOM
<br />COLOR INDICATOR
<br />FULL AND PARTIAL
<br />2-A2
<br />SECTION INDICATOR
<br />EXTERIOR AND INTERIOR
<br />ELEVATION INDICATOR
<br />SALES
<br />Fl-0-0-1 ROOM NAME AND NUMBER
<br />A6 PARTITION TYPE INDICATOR
<br />1Q1 DOOR INDICATOR
<br />OWINDOW INDICATOR
<br />OTV MONITOR
<br />An--- - COLUMN LINE INDICATOR
<br />jk 100'-0" HEIGHT ELEVATION INDICATOR
<br />100'-0" PLAN ELEVATION INDICATOR
<br />5
<br />A2
<br />( I ENLARGED DETAIL INDICATOR
<br />l
<br />5
<br />A2
<br />DETAIL INDICATOR
<br />TACTILE EXIT SIGN
<br />TACTILE SIGN REQUIREMENTS
<br />1. A TACTILE SIGN STATING "EXIT' AND COMPLYING WITH ANSI A117.1 SHALL BE PROVIDED ADJACENT
<br />TO EACH DOOR TO AN EXIT PASSAGEWAY AND THE EXIT DISCHARGE. REF FLOOR PLANS FOR
<br />LOCATIONS.
<br />2. FOR CHARACTER WIDTH, THE UPPERCASE LETTER "0" SHALL BE USED TO DETERMINE THE
<br />ALLOWABLE WIDTH OF ALL CHARACTERS OF A FONT. THE WIDTH OF THE UPPERCASE LETTER "0"
<br />OF THE FONT SHALL BE 55 PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE
<br />UPPERCASE "I" OF THE FONT. (ANSI A117.1-2009: 703.3.6) CHARACTER HEIGHT MEASURED FROM
<br />THE BASELINE OF THE CHARACTER SHALL BE 5/8" (16 MM) MINIMUM AND 2 INCHES (51 MM)
<br />MAXIMUM BASED ON THE HEIGHT OF THE UPPERCASE LETTER "I".
<br />3. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND.
<br />4. CHARACTERS SHALL CONFORM TO THE FOLLOWING:
<br />4.a. LETTERS AND NUMBERS ON SIGNS SHALL BE RAISED 1/32" MINIMUM AND SHALL BE SANS -
<br />SERIF UPPERCASE CHARACTERS ACCOMPANIED BY GRADE 2 BRAILLE.
<br />4.b. RAISED CHARACTERS OR SYMBOLS SHALL BE A MINIMUM OF 5/8" HIGH AND A MAXIMUM OF 2".
<br />5. CONTRACTED GRADE 2 BRAILLE SHALL BE USED. DOTS SHALL BE 0.090" (2.3 MM) TO 0.100" (2.5 MM)
<br />ON CENTER IN EACH CELL WITH 0.241" (6.1 MM) TO 0.300" (7.6 MM) SPACE BETWEEN CELLS. DOTS
<br />SHALL BE RAISED A MINIMUM OF 0.025" (0.6 MM) TO 0.037" (0.9 MM) ABOVE THE BACKGROUND.
<br />6. CHARACTERS SHALL BE 48" MINIMUM ABOVE FINISH FLOOR MEASURED FROM THE BASE OF THE
<br />LOWEST TACTILE CHARACTER AND 60" MAXIMUM ABOVE FINISH FLOOR MEASURED FROM THE
<br />BASELINE OF THE HIGHEST TACTILE CHARACTER.
<br />7, WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE ALONGSIDE THE DOOR AT
<br />THE LATCH SIDE. AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON
<br />THE INACTIVE LEAF. AT DOUBLE DOORS WITH TWO ACTIVE LEAVES, THE SIGN SHALL BE TO THE
<br />RIGHT OF THE RIGHT-HAND DOOR. TACTILE SIGNS ARE PERMITTED ON THE PUSH SIDE OF DOORS
<br />WITH CLOSERS AND WITHOUT HOLD -OPEN DEVICES. SEE ALTERNATE SOLUTIONS FOR OTHER
<br />SCENARIOS.
<br />PREFERRED SOLUTION
<br />SIGNS CONTAINING TACTILE I I
<br />CHARACTERS SHALL BE I
<br />LOCATED SO THAT THERE IS
<br />AN 18"X18" CLEAR FLOOR
<br />AREA CENTERED ON THE
<br />TACTILE CHARACTERS
<br />ALTERNATE SOLUTIONS
<br />L L L
<br />A. WHERE THERE IS NO B. THE REQUIRED SIGNAGE MAY
<br />ALTERNATE LOCATION WALL SPACE ON THE BE INSTALLED SO THAT THE
<br />(NEAREST ADJACENT LATCH SIDE OF A SINGLE CLEAR FLOOR AREA IS BEYOND
<br />WALL, RIGHT HAND SIDE DOOR, OR TO THE RIGHT THE ARC OF ANY DOOR SWING
<br />OF OPENING PREFERRED) SIDE OF DOUBLE DOORS, BETWEEN THE CLOSED POSITION
<br />SIGNS SHALL BE ON THE AND 45 DEGREE OPEN POSITION.
<br />NEAREST ADJACENT
<br />WALL,
<br />----\Yl --�r =-I--
<br />LJ I
<br />C. WHEN SIGN IS REQUIRED AT
<br />A BANK OF DOORS, PLACE (1)
<br />SIGN BETWEEN JAMBS. IF
<br />JAMB IS NOT WIDE ENOUGH FOR
<br />SIGNAGE, PLACE (1) SIGN AT
<br />RIGHT SIDE OF BANK OF DOORS.
<br />12" MIN
<br />E. WHERE WALL STANDARDS
<br />IMPEDE THE REQUIRED
<br />CLEAR FLOOR AREA, MOUNT
<br />SIGN DIRECTLY TO DOOR.
<br />ENSURE DOOR HAS
<br />AUTOMATIC CLOSER AND
<br />DOES NOT HAVE A
<br />HOLD -OPEN DEVICE.
<br />ALTERNATE LOCATION
<br />(NEAREST ADJACENT
<br />WALL, RIGHT-HAND SIDE
<br />OF OPENING PREFERRED)
<br />D. WHERE REFRIGERATED CASES OR
<br />FIXTURES IMPEDE THE REQUIRED
<br />CLEAN FLOOR AREA, MOUNT
<br />SIGNAGE TO THE END PANEL OF
<br />CASE OR OWNER PROVIDED END
<br />PANEL FOR HALF GONDOLAS AND
<br />WALL STANDARD FIXTURES.
<br />J
<br />12" MIN
<br />F. AT EGRESS DOORS IN THE
<br />GARDEN CENTER WHERE THERE
<br />IS NOT AMPLE WALL SPACE FOR
<br />SIGNAGE, MOUNT SIGN DIRECTLY
<br />TO DOOR. ENSURE DOOR HAS
<br />AUTOMATIC CLOSER AND DOES
<br />NOT HAVE A HOLD -OPEN DEVICE.
<br />'REFERRED
<br />RIGHT-HAND SIDE,
<br />kDJACENT TO DOOR)
<br />G. AUTOMATIC SLIDING DOOR
<br />LOCATIONS
<br />TACTILE SIGNAGE CANNOT
<br />BE LOCATED ON AUTOMATIC
<br />SLIDING DOOR PANELS.
<br />PANEL WIDTH TO MATCH
<br />OF WAREHOUSE RACK
<br />z
<br />0
<br />H
<br />w �-
<br />w
<br />ELEVATION PLAN
<br />H. WHERE WAREHOUSE RACKS IMPEDE THE REQUIRED CLEAR FLOOR AREA
<br />ADJACENT TO THE DOOR, PROVIDE 3/8" A-B PLYWOOD PANEL WITH EASED
<br />EDGES AND ATTACH TO THE END OF THE WAREHOUSE RACK USING (4)
<br />GALVANIZED CARRIAGE BOLTS, WASHERS AND LOCKNUTS. CARRIAGE BOLTS
<br />ARE TO BE SIZED PROPERLY TO ENSURE THE BOLT END DOES NOT
<br />PROTRUDE BEYOND THE TOP OF LOCKNUT AND PANEL IS SECURE. IN
<br />GROCERY SERVICE AND PREPARATION AREAS, PAINT PLYWOOD P33 UNO.
<br />SITE VERIFICATION REQUIREMENTS:
<br />1. THE ARCHITECT HAS NOT MADE A SCOPE VISIT. MEASUREMENTS AND PHOTOGRAPHS OF EXISTING CONDITIONS AND THE ARCHITECTURAL DRAWINGS
<br />INDICATE EXISTING CONDITIONS BASED ON AS BUILT AND PROTOTYPICAL INFORMATION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL
<br />EXISTING CONDITIONS PRIOR TO THE SUBMISSION OF A BID AND TO THE COMMENCEMENT OF ANY WORK. NO ADDITIONAL COMPENSATION WILL BE PAID
<br />DUE TO THE CONTRACTOR'S FAILURE TO VERIFY EXISTING SITE CONDITIONS WHICH INCLUDE, BUT ARE NOT LIMITED TO, GRADES, EXTENT OF PAVING, OR
<br />UTILITIES.
<br />2. ANY DISCREPANCY WITH THE EXISTING SITE CONDITIONS AND/OR THE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR
<br />CLARIFICATION AND INSTRUCTION. THESE CONSTRUCTION DOCUMENTS HAVE BEEN DESIGNED AND DRAWN ASSUMING EXISTING BUILDING CONDITIONS
<br />MATCH THE ORIGINAL DRAWINGS. THE GENERAL CONTRACTOR, IMMEDIATELY UPON ARRIVAL AT THE SITE, SHALL VERIFY ALL EXISTING STRUCTURAL
<br />COLUMN DIMENSIONS, STRUCTURAL BEARING HEIGHTS, EXISTING DIMENSIONS, TOP OF MASONRY ELEVATIONS, ROOFING CONDITIONS (INCLUDING
<br />PARAPETS, SCUPPERS AND ROOF DRAINS), AND JOIST BEARING ELEVATIONS PRIOR TO THE FABRICATION OF ANY STRUCTURAL ITEMS. IF DISCREPANCIES
<br />ARE FOUND BETWEEN WHAT IS SHOWN ON THE DRAWINGS AND EXISTING FIELD CONDITIONS, CONTACT THE WALMART CONSTRUCTION MANAGER AND THE
<br />ARCHITECT IMMEDIATELY TO DETERMINE WHAT ACTION SHOULD BE TAKEN TO MATCH EXISTING CONDITIONS. THE BEGINNING OF STRUCTURAL STEEL
<br />FABRICATION BY THE GENERAL CONTRACTOR, STEEL FABRICATOR, OR JOIST MANUFACTURER MEANS ACCEPTANCE OF THE EXISTING CONDITIONS.
<br />3. ALL UTILITY LOCATIONS SHOWN ARE APPROXIMATE. THE CONTRACTOR SHALL FIELD VERIFY THE EXACT LOCATION OF ALL EXISTING UTILITIES (WHETHER
<br />SHOWN OR NOT) PRIOR TO THE SUBMISSION OF A BID OR THE COMMENCEMENT OF CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE WALMART
<br />CONSTRUCTION MANAGER OF THE DISCOVERY OF EXISTING UTILITIES NOT SHOWN OR NOTED ON DRAWINGS.
<br />4. THE CONTRACTOR SHALL VERIFY AND MAINTAIN (REPAIR IF DAMAGED) EXISTING IRRIGATION SYSTEMS AFFECTED BY THE CONSTRUCTION OF THIS
<br />PROJECT.
<br />5. THE CONTRACTOR SHALL FIELD LOCATE AND VERIFY ALL PROPERTY LINES, EASEMENTS, SETBACKS AND RESTRICTIONS. A REGISTERED SURVEYOR SHALL
<br />ESTABLISH ALL PROPERTY LINES AND SETBACKS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION AND CLEARLY FLAG PROPERTY LINES AND SETBACKS.
<br />IT REMAINS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO DETERMINE EXACT LOCATION OF ALL SAID BOUNDARIES.
<br />6. THE CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND DEPTHS OF UNDERGROUND UTILITY SERVICES PRIOR TO ANY EXCAVATION.
<br />7. THE CONTRACTOR SHALL VERIFY ALL GRADES AND PROPOSED FINAL GRADES. IF RAMPS, STOOPS, STAIRS, SIDEWALKS, FLATWORK OR PAVING ARE
<br />INSTALLED, VERIFY FINAL GRADES SURROUNDING THE NEW CONSTRUCTION AND ADJUST STAIR RISERS, RAMP LENGTHS, LIMITS OF PAVING, ETC., TO
<br />ACCOMMODATE THE REQUIRED RAMP SLOPE, RISER HEIGHTS OR PAVING AREAS. ALL RAMPS AND STAIRS SHALL MEET ADA-ADAAGS (OR ADOPTED
<br />HANDICAP ACCESSIBILITY REQUIREMENTS). IF THERE IS A CONFLICT IN FIELD CONDITIONS, NOTIFY WALMART CONSTRUCTION MANAGER AND THE
<br />ARCHITECT PRIOR TO THE CONSTRUCTION OR ORDERING OF MATERIALS.
<br />8. NOT USED.
<br />9. NOT USED.
<br />10. NOT USED.
<br />11. REPORT ANY DISCREPANCIES FOUND IN THE FIELD IMMEDIATELY TO WALMART AND THE ARCHITECT PRIOR TO MAKING ANY STRUCTURAL MODIFICATIONS
<br />OR ORDERING OF ANY MATERIALS.
<br />GENERAL CONSTRUCTION REQUIREMENTS:
<br />1. ALL WORK SHALL BE DONE IN A SAFE AND WORKMANLIKE MANNER AND IN STRICT ACCORDANCE WITH THE LOCAL AND/OR STATE (IF APPLICABLE) BUILDING
<br />CODES, NATIONAL ELECTRIC CODE, ADA-ADAAG AND OTHER ADOPTED ACCESSIBILITY STANDARDS, OSHA, AND ALL APPLICABLE CODES, REGULATIONS,
<br />ORDINANCES AND AUTHORITIES HAVING JURISDICTION (AHJ).
<br />2. PROVISIONS REGARDING THE USE OF GAS AND DIESEL EQUIPMENT WITHIN AN ENCLOSED BUILDING, FORMERLY INCLUDED IN THIS PARAGRAPH, ARE NOW
<br />INCLUDED IN SECTION 01351 - REGULATORY COMPLIANCE
<br />3. PROVISIONS REGARDING CORDS FOR ELECTRICAL EQUIPMENT AND ROUTING OF EQUIPMENT CORDS AND HOSES, FORMERLY INCLUDED IN THIS
<br />PARAGRAPH, ARE NOW INCLUDED IN SECTION 01351 - REGULATORY COMPLIANCE
<br />4. EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE
<br />FAILURE TO REVIEW THESE DOCUMENTS DOES NOT RELIEVE THE SUBCONTRACTOR OF ANY RESPONSIBILITY FOR PERFORMING WORK PROPERLY. NO
<br />ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS
<br />KNOWLEDGE.
<br />5. THE EXISTING BUILDING SHALL BE PROTECTED FROM MOISTURE, DUST AND DEBRIS. INSTALL DUST PARTITIONS OR DRAPES AS REQUIRED AND/OR AS
<br />DIRECTED BY WALMART CONSTRUCTION MANAGER TO KEEP DUST AND MOISTURE FROM THE OPERATING AREAS OF THE STORE.
<br />6. ANY DAMAGE TO WALMART'S PROPERTY, WHICH OCCURS DURING THE PROCESS OF CONSTRUCTION SHALL BE REPAIRED/REPLACED AT NO ADDITIONAL
<br />COST TO WALMART; THIS INCLUDES ALL MERCHANDISE. CONTRACTOR SHALL PAY THE COST FOR ALL DAMAGED MERCHANDISE.
<br />7. THE CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE EXISTING BUILDING SECURITY AT ALL TIMES. THIS INCLUDES KEEPING THE BUILDING SECURE
<br />FROM PERSONS, ENVIRONMENTAL ELEMENTS OR HAZARDS. THE CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN THE INTEGRITY OF ALL EXISTING
<br />SECURITY SYSTEMS. THE CONTRACTOR SHALL OBTAIN PERMISSION FROM THE STORE MANAGER PRIOR TO THE MODIFICATION OF ANY EXISTING SECURITY
<br />SYSTEM FOR THE OPENING (DEMOLITION) OF ANY EXTERIOR WALL.
<br />8. THE CONTRACTOR SHALL KEEP THE WORK AREA CLEAN AND FREE OF DEBRIS AND REMOVE ALL TRASH AND DEBRIS FROM THE CONSTRUCTION AREA
<br />DAILY. NO FLAMMABLE MATERIALS OR LIQUIDS MAY BE STORED IN THE EXISTING BUILDING OR IN ANY NEW ADDITION.
<br />9. REMOVE ANY EXISTING EQUIPMENT, FIXTURES, FURNISHINGS, ACCESSORIES, SERVICES, FINISHES OR SURFACES AS REQUIRED SHOWN OR NOT SHOWN,
<br />FOR THE INSTALLATION OF NEW CONSTRUCTION. PROVIDE FURRING FOR CONDUITS AND PIPING, SHOWN OR NOT, AND FINISH OUT FURRING TO MATCH
<br />ADJACENT EXISTING FINISHES.
<br />10. REPAIR, RE-ROUTE, AND EXTEND ALL SERVICES, PIPING, CONDUIT OF EXISTING ITEMS AND EQUIPMENT AS REQUIRED DURING THE CONSTRUCTION
<br />PROCESS TO MAINTAIN NORMAL STORE OPERATIONS AND AS REQUIRED FOR THE INSTALLATION OF NEW CONSTRUCTION. THIS INCLUDES ALL ITEMS
<br />SHOWN OR NOT SHOWN ON THE DRAWINGS. RESET EXISTING EQUIPMENT, FIXTURES, FURNISHINGS, ACCESSORIES OR RELATED ITEMS AS REQUIRED FOR
<br />PROPER OPERATION.
<br />11. WHEN EQUIPMENT, FIXTURES, FURNISHINGS, ACCESSORIES, SERVICES, FINISHES OR SURFACES ARE TEMPORARILY REMOVED OR RELOCATED IN ORDER
<br />TO PERFORM WORK, THE CONTRACTOR IS RESPONSIBLE FOR RETURNING THEM TO THEIR ORIGINAL POSITION, RECONNECTION OF SERVICES AND
<br />APPROPRIATE MEANS OF ATTACHMENT UNLESS SPECIFICALLY DIRECTED TO DO OTHERWISE.
<br />12. WHERE EXISTING FINISHES ARE TO REMAIN, CLEAN, REPAIR, PATCH AND REPAINT AS NECESSARY TO BLEND IN WITH ADJACENT WORK. COORDINATE WITH
<br />WALMART CONSTRUCTION MANAGER
<br />13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE TIMELY ORDERING OF MATERIALS TO PROHIBIT DELAYS OF THE CONSTRUCTION SCHEDULE OF THIS
<br />PROJECT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE DELIVERY OF MATERIALS IN A TIMELY MANNER.
<br />14. NOT USED.
<br />15. THE GENERAL CONTRACTOR SHALL RESPOND TO ALL REQUIREMENTS OF THE STRUCTURAL ENGINEER/ARCHITECT FOR VERIFICATIONS, RESPONSES, AND
<br />SUBMISSIONS.
<br />16. IF MODIFICATION TO SPRINKLER SYSTEM IS REQUIRED THE GENERAL CONTRACTOR SHALL HIRE A LICENSED SPRINKLER CONTRACTOR. CONTRACTOR TO
<br />SUBMIT SIGNED AND SEALED SPRINKLER DRAWINGS FOR APPROVAL PRIOR TO ANY ALTERATION OF THE AUTOMATIC SPRINKLER SYSTEM. WORK TO BE
<br />DONE UNDER SEPARATE PERMIT.
<br />17. ALL ADJACENT BUILDINGS (IF APPLICABLE) SHALL REMAIN IN SERVICE DURING DEMOLITION/CONSTRUCTION.
<br />18. MUD AND DEBRIS TRACKED ONTO OWNER PAVING OR CITY STREETS TO BE CLEANED IMMEDIATELY.
<br />19. BUILDING COMPONENTS AFFECTED BY THE SCOPE OF WORK AND ALLOWED TO REMAIN SHALL BE SECURED TO PREVENT FALLING, LOOSENING, OR
<br />CREATING DAMAGE OF ANY KIND IN THE FUTURE.
<br />DEMOLITION REQUIREMENTS:
<br />1. ALL DEMOLITION SHALL BE CARRIED OUT IN A SAFE MANNER AND IN STRICT ACCORDANCE WITH OSHA REGULATIONS.
<br />2. THE CONTRACTOR SHALL FIELD VERIFY THE EXTENT OF DEMOLITION. THE WORK INCLUDES, BUT IS NOT LIMITED TO, THE DEMOLITION AND REMOVAL OF
<br />WALLS, DOORS, FIXTURES, PLUMBING, PAVING, MECHANICAL AND ELECTRICAL ITEMS INCLUDING CONDUITS AND DUCTWORK AS SHOWN ON DRAWING OR
<br />AS REQUIRED FOR THE INSTALLATION OF THE NEW WORK FOR A COMPLETE JOB.
<br />3. WHEN UTILITIES ARE REMOVED, CAP AND SEAL A MINIMUM OF 8" BELOW FINISH FLOOR OR A MINIMUM OF 6" ABOVE FINISH CEILING.
<br />4. WHEN REMOVING EXISTING STRUCTURAL ITEMS, IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SHORING, BRACING AND SUPPORT
<br />SYSTEMS TO KEEP THE EXISTING STRUCTURE INTACT AND IN A SAFE CONDITION. REFER TO SECTIONS 02023 AND 02251.
<br />5. THE CONTRACTOR MAY NOT REMOVE THE BLOCK WALL IN A PROPOSED OPENING PRIOR TO THE ROOFING SYSTEM OVER THE NEW ADDITION BEING MADE
<br />WATERTIGHT. COORDINATE WITH THE WALMART CONSTRUCTION MANAGER AND THE STORE MANAGER TO SCHEDULE FOR DEMOLITION FOR NEW
<br />OPENINGS.
<br />6. THE CONTRACTOR SHALL REMOVE ANY BUILDING SIGNAGE THAT INTERFERES WITH THE BUILDING ADDITION. WALMART WILL REINSTALL SIGNAGE OR ADD
<br />NEW SIGNAGE AT COMPLETION OF ADDITION.
<br />7. NOTES INDICATING DEMOLITION WORK ARE NOT CONFINED SOLELY TO THE DEMOLITION PLANS. THE GENERAL CONTRACTOR SHALL REVIEW ALL
<br />CONSTRUCTION DOCUMENTS, INCLUSIVE OF SCHEDULES AND SPECIFICATIONS, TO DETERMINE FULL EXTENT OF DEMOLITION WORK.
<br />ABBREVIATION LEGEND
<br />pb2
<br />hitecture
<br />gineering
<br />2809 Ajax Avenue Suite 100
<br />Rogers Arkansas 72758
<br />Phone: 479.636.3545
<br />Fax: 479.636.1209
<br />Architect of Record
<br />William Douglas Hurley
<br />Florida License No. AR 91919
<br />Architect Business Lic No.
<br />AA26000940
<br />y o oLL
<br />w w cwi o w z
<br />w W I US o
<br />! w a } to 05I'o 0 o i0a w i 0 3 m
<br />O N �� 0 a o a o W > p F - j
<br />z 3 LL o W y Cr o a U-j
<br />O o W o za
<br />g co _ R. ga o � 5 5E S
<br />a o o o � W � a ? 0 8.0
<br />. 0 a o
<br />N°
<br />O 0
<br />CD U Q
<br />J
<br />J � cr
<br />m m a
<br />v V J o 00
<br />U �J Q 0 to
<br />J (9 z °?
<br />w
<br />= M 0 C'4
<br />0
<br />Uj
<br />N w
<br />z
<br />m
<br />2021 CSP
<br />ISSUE BLOCK
<br />GENERAL
<br />ABBREVIATIONS
<br />ABBR
<br />DEFINITION
<br />AB
<br />ANCHOR BOLT
<br />ACI
<br />AMERICAN CONCRETE INSTITUTE
<br />ACRYL
<br />ACRYLIC
<br />ADA
<br />AMERICANS WITH DISABILITIES ACT
<br />ADJ
<br />ADJACENT
<br />AFF
<br />ABOVE FINISHED FLOOR
<br />AFG
<br />ABOVE FINISHED GRADE
<br />AISC
<br />AMERICAN INSTITUTE OF STEEL CONSTRUCTION
<br />ARCH
<br />ARCHITECTURAL
<br />ASTM
<br />AMERICAN SOCIETY OF TESTING AND MATERIALS
<br />AWS
<br />I AMERICAN WELDING SOCIETY
<br />BFF
<br />BELOW FINISHED FLOOR
<br />BL
<br />BLOCK LINTEL
<br />BO
<br />BOTTOM OF
<br />BOS
<br />OF STEEL
<br />BRG
<br />BEARIM
<br />NG
<br />CJ
<br />T
<br />L
<br />CENTERLINE
<br />CLR
<br />CLEAR
<br />CM
<br />CONCRETE MASONRY UNIT
<br />COL
<br />COLUMN
<br />CONC
<br />CONCRETE
<br />CONST
<br />CONSTRUCTION
<br />CONT
<br />CONTINUOUS
<br />CU
<br />CONDENSING UNIT
<br />DIA
<br />DIAMETER
<br />DSD
<br />DIRECTS SHIPPING DELIVERY
<br />EAS
<br />ELECTRONIC ARTICLE SURVEILLANCE
<br />EDC
<br />ELECTRICAL DISTRIBUTION CENTER
<br />EIFS
<br />EXTERIOR INSULATION AND FINISH SYSTEM
<br />EF
<br />EXHAUSTFAN
<br />EJ
<br />EXPANSION JOINT
<br />EL
<br />ELEVATION
<br />ELEC
<br />ELECTRICAL
<br />EQ
<br />EQUAL
<br />ETR
<br />EXISTING TO REMAIN
<br />EW
<br />EACH WAY
<br />EWC
<br />ELECTRIC WATER COOLER
<br />FDN
<br />FOUNDATION
<br />FF
<br />FINISHED FLOOR
<br />FRP
<br />FIBER REINFORCED PLASTIC
<br />FS
<br />FAR SIDE
<br />FTG
<br />FOOTING
<br />FV
<br />FIELD VERIFY
<br />GA
<br />GAUGE
<br />GC
<br />GENERAL CONTRACTOR
<br />GM_
<br />GENERAL MERCHANDISE
<br />GR
<br />GROCERY
<br />GYP BD
<br />GYPSUM BOARD
<br />HC
<br />HANDICAP
<br />HDTV
<br />HIGH DEFINITION TELEVISION
<br />FISA-
<br />HEADED STUD ANGHOK
<br />HSS
<br />HOLLOW STRUCTURAL SECTION
<br />INFO
<br />INFORMATION
<br />ISO
<br />ISOLATION
<br />JBE
<br />JOIST BEARING ELEVATION
<br />JST
<br />JOIST
<br />JT
<br />JOINT
<br />KS1
<br />KIPS PER SQUARE INCH
<br />L
<br />LENGTH
<br />LB
<br />POUNDS
<br />LLH
<br />LONG LEG HORIZONTAL
<br />LLV
<br />LONG LEG VERTICAL
<br />LONG
<br />LONGITUDINAL
<br />MAX
<br />MAXIMUM
<br />MAU
<br />MECHANICAL AIR UNIT
<br />ME
<br />MASONRY ELEVATION
<br />MECH
<br />MECHANICAL
<br />MEP
<br />MECHANICAL ELECTRICAL PLUMBING
<br />MFR
<br />MANUFACTURER
<br />MIN
<br />MINIMUM
<br />MISC
<br />MISCELLANEOUS
<br />MO
<br />MASONRY OPENING
<br />MTL
<br />METAL
<br />NIC
<br />NOT IN CONTRACT
<br />NO
<br />NUMBER
<br />NS
<br />NEAR SIDE
<br />NTS
<br />NOT TO SCALE
<br />Oc
<br />ON CENTER
<br />OD
<br />OUTSIDE DIAMETER
<br />OH
<br />OPPOSITE HAND
<br />PAF
<br />POWDER ACTUATED FASTENER
<br />PCF
<br />POUNDS PER CUBIC FOOT
<br />PFC
<br />PAINT, FIX, CLEAN
<br />PL
<br />PLATE
<br />PLAM
<br />PLASTIC LAMINATE
<br />PLANT
<br />PLASTIC
<br />PLF
<br />POUNDS PER LINEAR FOOT
<br />PMEJ
<br />PREMOLDED EXPANSION JOINT
<br />PSF
<br />POUNDS PER SQUARE FOOT
<br />PSI
<br />POUNDS PER SQUARE INCH
<br />PVC
<br />POLYVINYL CHLORIDE
<br />QN
<br />QUANTITY
<br />RC
<br />REFRIGERATION CONTRACTOR
<br />SIGNAGE LEGEND
<br />SDI
<br />� SIGN Sim
<br />00 SJ I
<br />0 SPECS
<br />SIGN, REF NOTE 3. SS
<br />FF STD
<br />STRUC
<br />1. REQUIRED ACCESSIBLE ELEMENTS SHALL BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY AT THE T&B
<br />FOLLOWING LOCATIONS: TEMP
<br />A. ACCESSIBLE ENTRANCES WHERE NOT ALL ENTRANCES ARE ACCESSIBLE THK
<br />B. ACCESSIBLE ROOMS WHERE MULTIPLE SINGLE -USER TOILETS ARE CLUSTERED AT A SINGLE LOCATION TO
<br />C. ACCESSIBLE CHECK-OUT AISLES WHERE NOT ALL AISLES ARE ACCESSIBLE. THE SIGN, WHERE PROVIDED, SHALL BE ABOVE TOC/TC
<br />THE CHECK-OUT AISLE IN THE SAME LOCATION AS THE CHECK-OUT AISLE NUMBER OR TYPE OF CHECK-OUT TOF
<br />IDENTIFICATION TOGB
<br />D. UNISEX TOILET AND BATHING ROOMS TOM
<br />E. ACCESSIBLE DRESSING, FITTING AND LOCKER ROOMS WHERE NOT ALL SUCH ROOMS ARE ACCESSIBLE TOP/TP
<br />2. DIRECTIONAL SIGNAGE INDICATING THE ROUTE TO THE NEAREST LIKE ACCESSIBLE ELEMENT SHALL BE PROVIDED AT THE TOS
<br />FOLLOWING LOCATIONS. THESE DIRECTIONAL SIGNS SHALL INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY: TRANS
<br />A. AT EACH SEPARATE -SEX TOILET INDICATING THE LOCATION OF THE NEAREST UNISEX TOILET TYP
<br />UNO
<br />3. TACTILE SIGNAGE SHALL BE LOCATED 48 INCHES (1220 MM) MINIMUM ABOVE THE FINISH FLOOR OR GROUND SURFACE, VCPFC
<br />MEASURED FROM THE BASE OF THE LOWEST TACTILE CHARACTER AND 60 INCHES (1525 MM) MAXIMUM ABOVE THE FINISH VERT
<br />FLOOR OR GROUND SURFACE, MEASURED FROM THE BASELINE OF THE HIGHEST TACTILE CHARACTER. WHERE A TACTILE W
<br />SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONGSIDE THE DOOR AT THE LATCH SIDE. WHERE A TACTILE WM
<br />SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHERE A
<br />TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO THE RIGHT OF THE
<br />RIGHT HAND DOOR. WHERE THERE IS NO WALL SPACE AT THE LATCH SIDE OF A SINGLE DOOR OR AT THE RIGHT SIDE OF
<br />DOUBLE DOORS, SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT WALL. SIGNS CONTAINING TACTILE CHARACTERS
<br />SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18 INCHES (455 MM) MINIMUM BY 18 INCHES (455 MM) MINIMUM,
<br />9E4
<br />TOP OF CONCRETE
<br />TOP OF PAVING
<br />VISION CENTER PAINT FIX
<br />DEFINITION LEGEND
<br />CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED FINAL MERCHANDISE PLAN - FINALIZED MERCHANDISE PRINT FROM WM
<br />POSITION AND 45 DEGREE OPEN POSITION. EXCEPTION: SIGNS WITH TACTILE CHARACTERS SHALL BE PERMITTED ON THE ALSO REFERRED TO AS THE DEAL BOX COPY
<br />PUSH SIDE OF DOORS WITH CLOSERS AND WITHOUT HOLD -OPEN DEVICES.
<br />4. CHARACTER AND SYMBOLS OF SIGNS SHALL BE IN CONTRAST WITH THEIR BACKGROUND AND SHALL BE EGGSHELL, MATTE, OR
<br />OTHER NON -GLARE MATERIALS OR FINISHES.
<br />5. ACCESSIBLE SIGNAGE SHALL USE GRADE 2 BRAILLE AND MUST COMPLY WITH ICC A117.1 SECTION 703.4 OR ADA SECTION 703.3.
<br />CHECKED BY:
<br />Checker
<br />DRAWN BY:
<br />Author
<br />PROTO:
<br />192
<br />PROTO CYCLE:
<br />8-27-21
<br />DOCUMENT DATE:
<br />10-1-21
<br />1
<br />DOCUMENTS THAT DO NOT
<br />HAVE THE ARCHITECT OR
<br />ENGINEER OF RECORD SEAL
<br />AND SIGNATURE SHALL BE
<br />CONSIDERED NOT FOR
<br />CONSTRUCTION
<br />GENERAL
<br />INFORMATION
<br />SHEET:
<br />N1
<br />
|