Laserfiche WebLink
A6 <br />A <br />ALL PLYWOOD ON SALES <br />EXISTING ROOF DECK <br />FLOOR SIDE OF PARTITION I <br />TO BE PAINTED P131 I <br />STUD TRACK <br />ATTACHED TO BOTTOM <br />OF DECK AT 48" O.C. I I <br />INSTALL CONTINUOUS LAYER <br />WALL TO BE REMOVED - <br />6 MIL POLY CLEAR SHEETING <br />FROM FLOOR TO ROOF DECK, <br />OVERLAPPED AT JOINTS A <br />MINIMUM OF 2'-0" AND I <br />CONTINUOUSLY TAPED AT ALL I I <br />EXISTING FINISH CEILING <br />JOINTS. SEAL VOIDS AT DECK <br />I I <br />I I <br />REMOVE CEILING PANELS <br />2 ROWS OF 2X BLOCKING <br />AND LIGHTS AT WALL I I <br />BETWEEN STUDS. LAP 6 MIL. I <br />LOCATION. GRID TO REMAIN. I I <br />POLY CLEAR SHEETING <br />SEAL CLEAR SHEETING I I <br />BETWEEN ROWS AND ATTACH I <br />AROUND GRID I I <br />@ 24" O.C. <br />2x BLOCKING BETWEEN ( I <br />6'-0" @ LOAD BEARING <br />STUDS, PROVIDE 2X I <br />BLOCKING BEHIND EACH <br />4'-0" ALL OTHER LOCATIONS <br />HORIZONTAL JOINT IN THE <br />PLYWOOD WALL COVERING <br />DEMO AREA <br />AND ATTACH PLYWOOD TO <br />STUDS AND BLOCKING AT <br />METAL STUDS @ 24" O.C.: I I <br />12"OC MAX, TYP <br />WALLS UP TO 14': I I <br />GA I I <br />XLS <br />FRP ON 1/2" C/D PLYWOOD I <br />WAL <br />WALIGHER THAN 14': <br />HI <br />OVER 6 MIL. POLY CLEAR <br />I I <br />6" X 18GA <br />SHEETING FROM FLOOR TO <br />BOTTOM OF FINISH CEILING. <br />3-5/8" x 22GA I I <br />INSTALL FULL SHEETS, LONG I I <br />METAL STUD <br />DIMENSION HORIZONTAL I I <br />BRACE @ 96 " I I <br />STUD TRACK. ANCHOR I I <br />O.C. <br />I <br />AT 48" O.C. I I <br />CONTRACTOR'S <br />OPTION FOR I I <br />CONTINUOUS SEALANT i i <br />ATTACHMENT <br />BETWEEN BOTTOM EDGE OF <br />FRP AND FINISH FLOOR I I <br />I I <br />FINISH FLOOR <br />CONTINUOUS SEALANT AGAINST TRACK <br />NOTE: TYPICAL AT FOOD AREAS WITH CEILINGS / NOT ON AN EXTERIOR WALL <br />TEMPORARY FRP <br />CLAD <br />BARRIER/DUST DRAPE <br />3/4" = 1'-0" <br />�k- <br />pm pr <br />add <br />"t <br />Low <br />• <br />CONTRACTOR NOTES: <br />1. SAWCUT EDGES SHALL BE STRAIGHT AND EITHER PARALLEL EXISTING CONTROUCONSTRUCTION JOINTS. SAWCUTS AT AN <br />ANGLE TO THE EXISTING CONTROL JOINT PATTERN WILL NOT BE ALLOWED UNDER ANY CIRCUMSTANCES. <br />2. PRIOR TO CUTTING, INSTALL 36" WIDE ROSIN PAPER EACH SIDE OF PROPOSED EDGE CUTS IN ORDER TO REDUCE SCARRING <br />OF SLAB THAT IS TO REMAIN. <br />3. NO OVERCUTTING SHALL BE ALLOWED AT EDGES OR CORNERS OF TRENCH AREA TO BE REMOVED. PORTIONS OF SLAB <br />WHERE OVERCUTS OCCUR SHALL BE REMOVED AND REPLACED AT THE CONTRACTOR'S EXPENSE, WITH NO EXTENSION OF <br />THE CONSTRUCTION SCHEDULE. <br />4. PERFORM CUTTING OF EXISTING CONCRETE SLABS IN ACCORDANCE WITH THE DETAILS AND SPECIFICATIONS USING SAWS <br />AND/OR CORE DRILLS. ALL SLAB CUTTING SHALL BE PERFORMED AT NIGHT AFTER THE BUILDING HAS CLOSED FOR <br />BUSINESS. JACK -HAMMERS OR EXPLOSIVES WILL NOT BE ALLOWED AT ANY TIME. <br />5. USE REMOVAL METHODS THAT WILL NOT CRACK, UNDERMINE, OR STRUCTURALLY DISTURB ADJACENT SLABS OR <br />PARTITIONS. <br />SLAB TRENCHING DETAIL <br />5 3/4" = 1'-0" <br />NOTE: 1 2 3 <br />THE GENERAL CONTRACTOR SHALL <br />REPAIR/REPLACE ANY DAMAGED FLOOR TILE <br />DUE TO INSTALLATION OR REMOVAL OF <br />TEMPORARY SECURITY ENCLOSURE. <br />CONTINUOUS SEALANT <br />2x WOOD PLATE <br />1/2" C/D EXT. PLYWOOD <br />SCREWED TO STUDS OVER <br />6 MIL CLEAR POLY SHEETS —� <br />EXISTING WALL TO <br />REMAIN <br />o Z <br />PAINT DUST WALLS TO MATCH <br />ADJACENT IF DUST WALLS TO <br />BE IN PLACE MORE THAN TWO <br />WEEKS. COORDINATE WITH <br />WALMART CONSTRUCTION <br />MANAGER <br />SALES <br />O <br />z <br />z <br />w <br />2x4 STUDS @ 24" a. <br />O <br />OC (TYPICAL) O <br />z <br />H <br />m <br />CONTINUOUS <br />SEALANT BOTH SIDES <br />OF SILL PLATE <br />MAMA <br />X <br />2x4 TREATED WOOD <br />SILL PLATE <br />SECURITY ENCLOSURE <br />3/4" = 1'-0" <br />ROOF DECK <br />CONTINUE PLYWOOD <br />TO DECK <br />1/2" CD PLYWOOD <br />4'-0"X8'-0" <br />HORIZONTAL <br />PROVIDE 2x4 NAILER <br />AT ALL JOINTS <br />INSTALL <br />CONTINUOUS <br />LAYER 6 MIL POLY <br />SHEETS TAPE ALL <br />JOINTS <br />2x4 AT 24" OC <br />SALES <br />PAINT DUST WALLS TO MATCH <br />ADJACENT IF DUST WALLS TO <br />BE IN PLACE MORE THAN TWO <br />WEEKS. COORDINATE WITH <br />WALMART CONSTRUCTION <br />MANAGER <br />DO NOT USE DUST <br />WALL TO SHORE ROOF <br />JOISTS <br />WALL TO <br />BE REMOVED <br />6'-0" LOAD BEARING <br />4'-0" ELSEWHERE <br />DEMO AREA <br />NOTES: <br />1. INSTALL TEMPORARY <br />WALL IN SECTIONS <br />APPROX 40'-0" PER DAY <br />(COORDINATE WITH STORE <br />MANAGER AND WALMART <br />CONSTRUCTION <br />MANAGER) <br />2. LOCATE VERTICAL 2x4'S <br />AS NOT TO INTERFERE <br />WITH CEILING GRID OR <br />LIGHT FIXTURES <br />3. LOCATE HORIZONTAL 2x4 <br />AT 2" ABOVE CEILING <br />EXCEPT LIGHT FIXTURE <br />LOCATIONS <br />4. SCREW PLYWOOD (MAX <br />SPACING 12" OC) <br />SEALANT UNDER CONTINUOUS SEALANT <br />BOTTOM PLATE AGAINST PLATE <br />ANCHOR AT 24" OC COORDINATE W/SPECIFICATION <br />SECTION 01500. <br />DUST WALL SECTION <br />DEMO AREA <br />REMOVE <br />STRIPING <br />TENANT SPACE <br />VISION CENTER DEMOLITION PLAN <br />4 5 <br />RESTROOM DEMOLITION TO INCLUDE BUT IS NOT LIMITED TO <br />• REMOVAL OF ALL PARTITIONS <br />• WALL FINISHES TO FACE OF STUDS INCLUDING BATT <br />VISION CENTER SALES REMOVE <br />MILLWORK AND WALL FIXTURES. <br />GC TO COORDINATE <br />RELOCATION OF VISION CENTER <br />EQUIPMENT WITH WMCM. <br />DEMOLITION LEGEND <br />EXISTING TO REMAIN <br />— — — DEMOLISH/REMOVE/RELOCATE <br />AREA TO BE DEMOLISHED <br />TERMITE CONTROL: <br />GC TO PROVIDE TERMITE CONTROL AT <br />REMOVAL OF CONCRETE SLAB(S) OR <br />TRENCHING PER FBC 2017 SECTION 18. <br />REFER TO SPEC SECTION 023161 FOR <br />MORE INFORMATION ON TERMITE CONTROL <br />WARRANTY, MATERIALS, EXECUTION AND <br />APPLICATION. <br />SHEET NOTES <br />1. SALES FLOOR TO BE ACCESSIBLE TO CUSTOMERS <br />DURING NON -CONSTRUCTION HOURS. PROVIDE <br />TEMPORARY COVERS CAPABLE OF WITHSTANDING <br />SHOPPING CART TRAFFIC AND OCCUPANTS FOR PITS <br />AND TUNNELS, REMOVE CONSTRUCTION FENCING AND <br />DUST WALLS INTERFERING WITH CUSTOMER <br />CIRCULATION OR ACCESS.. <br />2. DEMOLITION INCLUDES BUT IS NOT LIMITED TO ITEMS <br />SHOWN DASHED. REF DEMOLITION REQUIREMENT NOTE <br />ON N1 SHEET. <br />3. REMOVE ALL DOORS SHOWN DASHED. REFER TO <br />ENLARGED PLANS AND DOOR SCHEDULE FOR DOOR <br />AND FRAME REPLACEMENT. <br />4. REMOVE CARPET AND GLUE FROM COLUMNS. PATCH <br />AND REPAIR COLUMNS TO SMOOTH SURFACE PRIOR TO <br />PAINTING <br />5. COORDINATE REMOVAL AND DISPOSAL OF EXISTING <br />REFRIGERATED CASES AND FIXTURES WITH <br />MECHANICAL SERVICES CONSTRUCTION MANAGER <br />6. REMOVE EXISTING FITTING ROOMS <br />EXISTING CONCRETE SLAB <br />4" CONCRETE SLAB <br />1/2" X 8" SMOOTH DOWELS AT 6" FROM EACH <br />CORNER AND AT 16" OC MAX EACH SIDE. <br />EMBED 4 1/2" MIN. INTO EXISTING CONCRETE <br />WITH HILTI HIT-HY 150 MAX ADHESIVE <br />RAPID SET CONCRETE MIX (BY GC) <br />EXISTING TUNNEL PENETRATIONS <br />(CONFIGURATION VARIES) <br />FILL UNUSED TUNNEL OPENINGS WITH COPPER <br />MESH AND EXPANDING FOAM TO 6" THICK MIN <br />A _ INFILL EXISTING PIT <br />WITH AGGREGATE <br />BASE <br />o- EXISTING <br />REFRIGERATION PIT <br />. d 9 <br />° ° d <br />CONCRETE PIT COVER DETAIL <br />7 1" = 1'-0" RM SC: RD1 RM WMN: — <br />11 12 13 14 15 <br />o <br />2 <br />k� <br />i <br />AREA OF <br />TRENCHING REF <br />PLUMBING AND <br />REF 5 - D1 <br />II f <br />� I <br />i <br />REMOVE AREA OF L REMOVE EXISTING RESTROOM DEMOLITION TO INCLUDE BUT IS NOT LIMITED TO: <br />ENTRY TILE TRENCHING REF COUNTERTOPS REMOVAL OF ALL PARTITIONS <br />PLUMBING AND o WALL FINISHES TO FACE OF STUDS INCLUDING BATT INSULATION <br />REF 5 - D1 o FLOOR FINISHES TO BARE CONCRETE <br />• LAVATORIES <br />• ALL ACCESSORIES <br />DEMOLITION PLAN TEMPORARY REMOVAL OF WATER CLOSETS REF 3-D1 FOR <br />SECURITY ENCLOSURE <br />a <br />8 =)OW <br />w W� <br />a j (A W = N <br />to OdN�a owf2"xLuc <br />p�F�ap-�iU!¢ <br />w W=S�a'LLZ�1-ZOO <br />� �a~WOZOw2OQN?� <br />w a.N W—W <br />O W���W3�=��oO� <br />ti <br />7 U U W W O> F <br />O 3mzqo,yw�wW�oo <br />?ILIQtL W J Z <br />J 30a 'wUE;-w - <br />a �rn <br />w0Wa�wZZW� <br />TazwLLwLL'ooc��'oyo <br />f4 9-OUo0F_w WoILm <br />F- <br />Q <br />J <br />M <br />to <br />z <br />O <br />U <br />m <br />'^. <br />VI <br />0 O <br />� <br />w <br />L'7 � c+� <br />M <br />0 0 <br />LL <br />N <br />o <br />�, <br />�_� <br />=o <br />w <br />a <br />oll O l <br />NZ <br />m <br />Lo <br />N <br />j W <br />Of <br />c <br />=mo <br />% <br />� <br />0 <br />� <br />w <br />N co <br />ti <br />w <br />m <br />D <br />z <br />m <br />O <br />ISSUE BLOCK <br />1 ADD1 01/27/21 <br />2 <br />ADD3 <br />02/26/21 <br />3 <br />CCD1 <br />03/29/21 <br />4 <br />CCD4 <br />06/21/21 <br />5 <br />CCD5 <br />08/16/21 <br />CHECKED BY: <br />RD <br />DRAWN BY: <br />EB <br />PROTO CYCLE: <br />09/25/20 <br />DOCUMENT DATE: <br />11/06/20 <br />DEMOLITION <br />PLAN <br />SHEET: <br />D 1 <br />co c> <br />3/4" = 1'-0" <br />1 " = 30'-0" <br />