Laserfiche WebLink
GRID WALL LEGEND <br />FIXTURE #: <br />BLOCK: <br />BLOCK NAME: <br />1ST SAP ARTICLE #: <br />SAP ARTICLE DESCRIPTION: <br />2ND SAP ARTICLE #: <br />SAP ARTICLE DESCRIPTION: <br />FIXTURE #: <br />BLOCK: <br />BLOCK NAME: <br />1ST SAP ARTICLE #: <br />SAP ARTICLE DESCRIPTION: <br />2ND SAP ARTICLE #: <br />SAP ARTICLE DESCRIPTION: <br />1-L <br />SCO_1BAG_GRIDSHELF_L_RSR <br />100625318 <br />D82 SCOWIRE MERCH SGL BAG <br />g_L <br />SCO_GRIDSHELF_30L_LEG _RSR <br />100627715 <br />301N ANCHORED SHELF KIT <br />2-L <br />SCO_1BAG_GRIDSHELF_L_2LEG_RSR <br />100625318 <br />D82 SCOWIRE MERCH SGL BAG <br />100627736 <br />LEG KIT <br />8-R <br />SCO_GRIDSHELF_30R_LEG _RSR <br />100627715 <br />301N ANCHORED SHELF KIT <br />1-R <br />I <br />SCO_16AG_GRIDSHELF_R_RSR <br />100625318 <br />D82 SCOWIRE MERCH SGL BAG <br />9-L <br />SCO_GRIDSHELF_48L_RSR <br />100627639 <br />481N SHELF BRIDGE KIT <br />SCO_GRIDSHELF <br />2-R <br />SCO_1BAG_GRIDSHELF_R 2LEG_RSR <br />100625318 <br />D82 SCOWIRE MERCH SGL BAG <br />100627736 <br />LEG KIT <br /><10-0 <br />48L_LEG_RSR <br />100627782 <br />481N ANCHORED SHELF KIT <br />3-L <br />1 <br />SCO_2BAG_GRIDSHELF_L_RSR <br />100625360 <br />D82 SCOWIRE MERCH DBL BAG <br />9-R <br />SCO_GRIDSHELF_48R_RSR <br />100627639 <br />481N SHELF BRIDGE KIT <br />Tin100625360 <br />4-L <br />SCO 2BAG_GRIDSHELF_L_2LEG_RSR <br />D82 SCOWIRE MERCH DBL BAG <br />100627736 <br />LEG KIT <br /><10-R> <br />SCO_GRIDSHELF_48R_LEG_RSR <br />100627782 <br />481N ANCHORED SHELF KIT <br />3-R <br />SCO_2BAG_GRIDSHELF_R RSR <br />100625360 <br />D82 SCOWIRE MERCH DBL BAG <br />11 <br />11 <br />SCO_GRID _36 <br />100634549 <br />361N SPACER <br />4-R <br />SCO_2BAG_GRIDSHELF_R 2LEG_RSR <br />100625360 <br />D82 SCOWIRE MERCH DBL BAG <br />100627736 <br />LEG KIT <br /><12-L> <br />SCO_GRIDSHELF_51L_30x8_RSR <br />100647056 <br />® <br />V` <br />5 <br />O <br />SCO_GRID_30 <br />100627735 <br />301N SPACER <br /><12-R> <br />� <br />SCO GRIDSHELF_51 R_30x8_RSR <br />_ <br />100647056 <br />� <br />5-L <br />SCO_GRID_30L_LEG <br />100627735 <br />100627736 <br />LEG KIT <br /><13-L> <br />U <br />SCO_GRIDSHELF 51L LEG_30x8_RSR <br />100647056 <br />5-R <br />SCO_GRID 30R_LEG <br />_ <br />100627735 <br />100627736 <br />LEG KIT <br /><13-R> <br />SCO_GRIDSHELF_51 R LEG_30x8_RSR <br />100647056 <br />6 <br />O <br />SCO_GRID_51 <br />100631063 <br />511N SPACER <br />< L> <br />SC0_GRIDSHELF_30L 20x10_RSR <br />100647055 <br />6-L <br />SCO_GRID_51L_LEG <br />100631063 <br />100627736 <br />LEG KIT <br /><15-R> <br />SCO_GRIDSHELF_30R_20x10_RSR <br />100647055 <br />U <br />V` <br />6-R <br />SCO_GRIDSHELF_30L_LEG <br />100647055 <br />® <br />SCO_GRID 51 R_LEG <br />- <br />100631063 <br />100627736 <br />LEG KIT <br />16-L <br />_20x10_RSR <br />7-L <br />SCO_GRIDSHELF_30L RSR <br />100627783 <br />301N BRIDGE SHELF KIT <br /><16-R> <br />40 <br />SCO_GRIDSHELF_30R_LEG _20x10_RSR <br />100647055 <br />Corner Kit <br />7-R <br />SCO_GRIDSHELF_30R RSR <br />100627783 <br />301N BRIDGE SHELF KIT <br />(Angle Iron <br />for Bullpen <br />100627800 <br />Comer Kit <br />Comers) <br />g <br />SCO_GRIDSHELF_30_2_LEG_RSR <br />5 <br />RELOCATED <br />CHICKEN AND rL <br />BREAD WARMER, 16'-4" <br />REF ELECTRICAL <br />16'-0" <br />16'-0" <br />v <br />16'-8" <br />16'-8" <br />REF REFRIGERATED <br />CASE LEGEND ON GA1 <br />0 <br />CO <br />0 <br />Zc <br />o-Q <br />ENLARGED REFRIGERATION <br />SHEET NOTES <br />1. ALL ELECTRICAL WORK INCLUDING DATA AND POWER DISCONNECTION BY GC. <br />2. REMOVAL AND REINSTALLATION OF POWER POLES BY GC. INSTALLATION OF NEW <br />POWER POLES BY GC. <br />3. ALL REGISTERS TO BE REMOVED AND REINSTALLED OR INSTALLED NEW BY <br />WALMART. <br />4. GENERAL CONTRACTOR RESPONSIBLE FOR ALL ELECTRICAL WORK. <br />5. GENERAL CONTRACTOR RESPONSIBLE FOR ANCHORS AND ALL GONDOLA <br />ANCHORAGE. <br />6. GENERAL CONTRACTOR TO REPAIR FLOOR AS REQUIRED AT LOCATIONS OF <br />REMOVED REGISTERS AND FIXTURES. <br />7. GENERAL CONTRACTOR TO REFER TO FIXTURE ANCHORAGE PLAN FOR ANCHORAGE <br />REQUIREMENTS. <br />8. GENERAL CONTRACTOR TO ACCESS GENERAL CONTRACTOR PERMIT <br />INFORMATION FOLDER ON WORKSPACE FOR GRID WALL INSTALLATION <br />INSTRUCTIONS. <br />9. GENERAL CONTRACTOR TO INSTALL RAILING PER MANUFACTURERS <br />RECOMMENDATIONS AND INSTRUCTIONS FOR INSTALLATION AND ANCHORING. <br />10. CAULK BASE OF ALL CHECKOUTS TO FLOOR WHEN LOCATION IS FINALIZED. <br />2 <br />NEW REFRIGERATED CASE <br />_TAL STUD <br />ID GYP. BD. <br />LASE <br />ICLOSURE <br />REFRIGERATION CHASES <br />6 it <br />DETAIL GM SIDE <br />NEW REFRIGERATED CASE <br />®■ METAL STUD <br />AND GYP. BD. <br />Y6 CHASE <br />c ENCLOSURE <br />N Y6 <br />T-0" <br />REFRIGERATION CHASE <br />PLAN GR SIDE DETAIL GR SIDE ng <br />1 /4" = V-0" <br />7 <br />16'-8" <br />I <br />GRID WALL FURNISHED BY <br />12' RD1069.652 GRID WALL FURNISHED BY NEW REGISTERS TYP OF, 12 WALMART AND INSTALLED BY GC. <br />REFRIGERATED CASE WALMART AND INSTALLED BY GC. REF ELECTRICAL REFERENCE MANUFACTURERS <br />(BOTTOM FED) r REFERENCE MANUFACTURERS <br />INSTALLATION MANUAL, TYP <br />12'-3" INSTALLATION MANUAL, TYP I I <br />NEW MERCHANDISE 17'-2" <br />If <br />_LL4 <br />h In ci <br />8' RD1069.652 <br />REFRIGERATED <br />(BOTTOM FED) <br />ENLARGED REFRIGERATION <br />PLAN GM SIDE <br />1/4" = 1'-0" <br />i 15'-9" <br />04 <br />A5.4 q <br />I M <br />I�• I 18'-7" <br />IL <br />I I <br />I <br />R.— <br />------- ■ ■ ■ <br />ICI <br />2) <br />ENLARGED CHECKOUT PLAN <br />5 <br />REMOVE <br />REMOVE PICKUP MERCHANDISE <br />LOCKERS AND <br />PATCH AND REPAIR CONCRETE MONITOR, REF MEP <br />IN ACCORDANCE WITH — — <br />SPECIFICATION SECTION 03905 REMOVE PICKUP — <br />TOWER, REF MEP I 1 <br />AFTER REMOVAL OF PICKUP <br />TOWER AND LOCKERS, GC TO <br />CLEAN, PATCH AND REPAIR <br />FLOOR AS REQUIRED TO <br />MATCH EXISTING FLOORING <br />CONDITIONS <br />• GC SHALL DEMO THE <br />TOWER <br />• WALMARTS REX TEAM <br />WILL REMOVE THE <br />COMPUTER <br />COMPONENTS AND <br />RETURN TO USED <br />ASSETS. REFER TO <br />SPECS SECTION 02023 <br />• GC SHALL PLACE THE <br />RECYCLABLE PARTS IN <br />THE APPROPRIATE <br />RECYCLING BINS AND <br />PROPERLY DISPOSE OF <br />ANY REMAINING ITEMS <br />CONTACT: <br />PROJECT SPECIFIC WM REALTY <br />EXECUTION MANAGER <br />9'-0" <br />CL <br />REMOVE <br />MERCHANDISE 1L — it <br />I <br />II II <br />REMOVE PICKUP TOWER i Ih I b V L <br />F) i i I I <br />- <br />REMOVE PICKUP I — I I =1 <br />LOCKERS AS SHOWN l — <br />DASHED, TYP <br />RELOCATE SELF -CHECKOUTS <br />AS SHOWN, TYP I I II - <br />I <br />T <br />I � - <br />I I --L-� <br />B _ I � ❑ I— <br />Ilr=� <br />ENLARGED CHECKOUT DEMO PLAN <br />15'-2" <br />N <br />CV <br />1 6'-3" <br />6'-3" <br />I I III <br />I <br />1-4 <br />III 1 <br />+��'MP3 <br />1 <br />P" <br />Ali I iq 1111 <br />I <br />o <br />REMOVE REGISTERS AS <br />SHOWN DASHED, TYP <br />6'-3" <br />6,-3■ <br />6'-3" <br />6'-3" <br />6'-3" <br />9'-0" U T-8" 19'-6" <br />c <br />I <br />M <br />LO <br />I <br />7 <br />REMOVE REMOVE <br />MERCHANDISE MERCHANDISE <br />� I\ <br />Y T II <br />I I I <br />lil 111 ��� ICI I I� <br />L J _► I I _I <br />11 I PI F-- I I I I I I I I III I�� <br />it <br />II �� <br />7�, <br />I ICI I <br />Il�l�pl I I I I_I I I I � <br />�d I I I I I I <br />L <br />I I <br />I I I ❑ _I I r lll� <br />REMOVE MERCHANDISE <br />AS SHOWN DASHED, TYP <br />T-10" 19'-6" <br />v <br />19'-9" 1'-3" 18'-4" <br />50'-4" <br />5 1/2" = V-0" <br />I <br />7 T� <br />8 RELOCATION OF EXISTING AND/OR INSTALLATION OF NEW <br />PREFABRICATED CASH WRAP(S) FOR CHECKOUTS BY WALMART. <br />PRIOR TO RELOCATION AND INSTALLATION VERIFY FINAL LOCATION <br />WITH STORE PLANNING FIELD PROJECT MANAGER. GENERAL <br />CONTRACTOR TO CAULK BASE TO FLOOR WHEN LOCATIONS <br />FINALIZED. <br />NEW CHECKOUT LAYOUT, NEW REGISTERS AND EQUIPMENT BY <br />REF E1 FOR POWER OWNER, REF ELEC (TYP) <br />11'-0" <br />I L <br />3 <br />YA5.4 <br />1 ----- ....... <br />8,-8" V-6 <br />"1 I <br />I I <br />I I <br />I <br />I <br />1 I <br />e <br />I o <br />I I `° <br />8'-6.1 ( 18'-6" jI <br />PU PANEL <br />I <br />I o <br />I w I <br />4 z <br />I cc d ( s <br />I Q J <br />1 co .— W <br />------ d� e z <br />b ❑CO <br />oQ <br />a <br />PU PANEL NEW <br />5'-7" 16'-11" REF 12 - A3 <br />MERCHANDISE, TYP <br />T-5" 17'-9" 18'-10" 1 <br />3 <br />n I <br />REMOVE <br />MERCHANDISE <br />I I <br />— RELOCATE REGISTERS AS <br />SHOWN DASHED, TYP <br />REMOVE MERCHANDISE <br />T I AS SHOWN DASHED, TYP <br />I I <br />I I I I �- -1 <br />REMOVE LOW <br />WALL <br />II 7 <br />I I <br />RELOCATE SELF -CHECKOUTS <br />AS SHOWN, TYP <br />IIIII I I �� I <br />Lq� <br />1 \U- <br />❑ <br />a <br />iwg =oam } <br />w <br />p F �a0a <br />w <br />WVW�I-a <br />W�LL��Zd'FZZW <br />�a-wozOy=OaN�y <br />~z Ol <br />003m'wT <br />WwZ}�ONOO <br />ZV�~w5uj <br />-Z <br />D <br />a. <br />a6Wmi~JwV~z <br />awfWWnuMBLU <br />aZ , , 0V <br />W <br />Tzo <br />FOuppFkx OWpdm <br />z <br />H <br />J <br />D <br />cn <br />z <br />O <br />U <br />tr <br />m <br />a <br />m <br />%49 <br />C) C= J cv) <br />d % <br />uU- <br />U) J N <br />o <br />it CO <br />0 <br />. j=o <br />n- <br />V\"' 1 <br />\/ <br />C <br />N Z <br />N <br />M <br />co <br />N <br />0 W <br />�m0 <br />og <br />WV_ <br />N "' <br />ti <br />w <br />m <br />D <br />z <br />in <br />O <br />ISSUE BLOCK <br />1 ADD1 01/27/21 <br />2 ADD3 02/26/21 <br />3 CCD4 06/21 /21 <br />4 CCD5 08/16/21 <br />CHECKED BY: <br />RD <br />DRAWN BY: <br />LR/SFvF <br />PROTO CYCLE: <br />09/25/20 <br />DOCUMENT DATE: <br />11/06/20 <br />08/16/21 <br />ENLARGED <br />PLANS AND <br />DETAILS <br />1 /8" = V-0" <br />ADDED ENTIRE NEW SHEET <br />SHEET: <br />A5.4 <br />