Laserfiche WebLink
91 <br />MODULAR FEATURE WITH 2"X <br />3/4" WOODEN SLATS PRE <br />SPACED 2" APART FURNISHED <br />BY OWNER, INSTALLED BY GC <br />DATA AND ELECTRICAL <br />RECEPTACLES <br />r uc o — <br />PREFINISHED <br />PS7 +** + <br />4" BASE <br />RB5 <br />MONITOR WALL ELEVATION <br />1/2" = V-0" <br />OWNER FURNISHED 3RD <br />PARTY INSTALLED 55" <br />DIGITAL DISPLAY <br />MOUNTED VERTICALLY <br />DIGITAL DISPLAY <br />MOUNTING BRACKET <br />OWNER FURNISHED, GC <br />INSTALLED <br />P208 <br />EXTERIOR 4TH WALL ELEVATION <br />1 /4" = 1'-0" <br />54'-6" <br />EXTENTS OF SLAT WALL <br />3 <br />54'-6" <br />4'-0 HIGH VINYL <br />CORNER GUARD <br />6 - VC1 <br />TYPICAL ALL OUTSIDE <br />---------------------- <br />CORNERS <br />9'-0" <br />25'-5" <br />i <br />i <br />L--------------------- <br />— -- - <br />17 L I <br />■ <br />i = <br />I <br />M <br />T-10" <br />o <br />I <br />I <br />3-VC2 <br />�? <br />OPTICAL SALES 15" 3'-11" <br />1'-0" 1'-5" 1 V-5" 1'-5" 8" T-11" <br />ECEPTION <br />N I co <br />I <br />700 <br />r - - - - - - - - - - - - - - - - - - - - - - - - -- <br />4'-0'HIGH VINYL ti <br />1 I 3 <br />CORNER GUARD, <br />' <br />> <br />i <br />I I 700D <br />TYPICAL ALL <br />708 <br />I <br />I I <br />' <br />OUTSIDE <br />16' - 3 5/8" <br />I <br />I <br />I <br />I <br />i <br />i <br />t CORNERS <br />= <br />6' - 2" <br />I 5'-3" <br />I 4'-6" I T-8" N <br />i <br />`- <br />5-VC2 <br />o I > <br />� CDo> <br />T-9" <br />T-1" <br />2'-10" <br />I <br />I <br />I <br />I <br />I I N <br />I I <br />i <br />I <br />I <br />I 2 <br />I <br />■ I <br />I <br />I <br />I I <br />� <br />> <br />_ <br />r <br />ZD <br />■ <br />w <br />� 1 - VC2 <br />■ <br />U <br />U <br />71-8" <br />11" <br />9" 7'-8" 1'-0" 71-8" <br />9" ■ <br />Lo <br />> <br />> <br />■ <br />2'_5• co <br />■ <br />len <br />_ <br />--- - <br />9'-8" <br />141-211 <br />- ------ ------ <br />VISION CENTER FLOOR PLAN. <br />A IA" — A$ A" <br />700 OPTICAL SALES <br />WALLS <br />• PAINT WALLS P207, UNO. <br />• REFERENCE PLANS FOR LOCATIONS OF ACCENT WALL <br />COLOR, P208. <br />• INSTALL NEW BASE RB5. <br />FLOORS <br />• REMOVE EXISTING FINISHED AND PREP SURFACE FOR <br />NEW POLISHED CONCRETE FLOOR THROUGHOUT. REF <br />SHEET A1.1. <br />• TRANSITION STRIPS PROVIDED BY WALMART, INSTALLED <br />BY CONTRACTOR. REFERENCE <br />CELING <br />• INSTALL NEW ACT-3 TILE AND INTERMEDIATE TEES <br />• REFERENCE ELECTRICAL AND MECHANICAL FOR NEW <br />LIGHT AND DIFFUSER LOCATIONS. <br />• REFERENCE FIRE PROTECTION FOR NEW SPRINKLER <br />SYSTEM. <br />• COORDIANTE NEW SECURITY CAMERA LOCATIONS WITH <br />NEW ACT TILES. <br />• INSTALL NEW CEILING FEATURE. <br />CASEWORKIMILLWORK <br />• ALL OWNERFURNISHED, GC INSTALLED CASEWORK. <br />701 ADJUSTMENTS <br />ITEMS TO BE RELOCATED FROM THE EXISTING VISION CENTER: STORE PLANNING TO <br />RELOCATE EQUIPMENT. GC TO RELOCATE MILLWORK AND CONNECT TEMPORARY <br />WALLS <br />POWER. WM TO INSTALL TEMPORARY DATA. COORDINATE WITH VC MANAGER. <br />• PAINT WALLS P207, UNO. <br />CURRENT POS CASH WRAP: <br />• INSTALL NEW BASE RB5. <br />REGISTER <br />• PIN PAD <br />FLOOR <br />SCANNER <br />• REMOVE VCT. POLISH NEWLY EXPOSED CONCRETE. REF <br />PRINTER / FAX <br />A1.1 FOR ADDITIONAL SOW. <br />CISCO PHONE <br />• BLACK BOX FOR HIPAA STORAGE OR SHREDDER <br />CELING <br />IPADS <br />• CLEAN CEILING TILES, GRID, AIR GRILLES/DIFFUSERS, <br />FITTING TABLE: <br />SECURITY GLOBES, SPRINKLER HEADS, AND LIGHT <br />ONE BOSS TERMINAL WITH PRIVACY SCREEN <br />LENSES. <br />2-3 CHAIRS <br />• PATIENT MIRRORS <br />CASEWORKIMILLWORK <br />FILING CABINETS: <br />• ALL OWNER FURNISHED, GC INSTALLED CASEWORK. <br />2 DRAWER FILING CABINET FOR CURRENT PATIENT RECORDS AWAITING <br />ORDER PICK UP / CAN ALSO BE USED FOR STORAGE OF CONTACT LENSES <br />CABINET: <br />• ONE TRAY PROCESSING LOCKING CABINET TO STORE DISPENSING TRAYS FOR <br />PATIENT ORDERS / CAN ALSO BE USED FOR STORAGE OF CONTACT LENSES <br />OPTICAL EQUIPMENT: <br />• LENSOMETER <br />• FRAME WARMER <br />• CURRENT TOOLS FOR ADJUSTMENTS (TOOLS, SCREWS, PARTS, ETC) <br />• ULTRASONIC CLEANER <br />• TRACER <br />• PUPILOMETER <br />• TC70 OR MC40 <br />SPACE ON CASH WRAP AREA TO DISPLAY: <br />• LICENSES (VC AND OPTICIAN LICENSES AS REQUIRED BY LAW) <br />• HOURS OF OPERATIONS SIGN <br />• HIPAA, LEP, ADA AND OTHER COMPLIANCE SIGNS <br />SHEET NOTES <br />1. ALL ELECTRICAL WORK INCLUDING DATA AND POWER <br />DISCONNECTION BY GC. <br />2. REMOVAL OF POWER POLES AND REINSTALLATION OF <br />NEW POLES BY GC. DATA LINES BY OTHERS. <br />3. GENERAL CONTRACTOR RESPONSIBLE FOR ALL <br />ELECTRICAL AND PLUMBING WORK. <br />4. GC RESPONSIBLE FOR ANCHORING ALL MILLWORK TO <br />PREVENT OVERTURNING, REFERENCE MILLWORK <br />MANUFACTURERS INSTRUCTIONS FOR CLEAT HEIGHTS. <br />5. CAULK ALL COUNTERS AND BACKSPLASHES TO THE <br />WALL <br />6. PATCH AND REPAIR WALLS AT ANY REMOVED <br />ELECTRICAL BOXES. <br />7. ALL NEW COUNTERS, CASEWORK, SHELVES, MILLWORK, <br />DISPENSERS, ARE TO BE FURNISHED BY WALMART AND <br />INSTALLED BY GC. <br />8. COMPUTER SYSTEMS AND EQUIPMENT FURNISHED <br />AND INSTALLED BY OWNER UNO. <br />9. INTERIOR PLAN DIMENSIONS ARE TO FACE OF FINISH <br />AT EXISTING WALLS. <br />10. IF SOUND ATTENUATION INSULATION DOES NOT EXIST <br />IN EXISTING EXAM ROOM WALLS ADJACENT TO <br />RESTROOM, INSTALL CONTINUOUS SOUND <br />ATTENUATION INSULATION FLOOR TO CEILING. <br />11. IF SOUND ATTENUATION INSULATION DOES NOT EXIST <br />IN EXISTING EXAM ROOM CEILING, INSTALL NEW SOUND <br />ATTENUATION INSULATION ABOVE THE CEILING. <br />12. UNLESS FLOOR BOXES ARE STILL IN SERVICE <br />EXISTING FLOOR BOXES IN VISION CENTER TO BE <br />ABANDONED, REF ELECTRICAL FOR DEMOLITION OF <br />EXISTING CIRCUITRY. REMOVE AND INFILL ABANDONED <br />FLOOR RECESSED ELECTRICAL AND DATA OUTLETS. <br />PATCH AND REPAIR SUBSTRATE FOR NEW FLOOR <br />FINISHES. <br />13. ALL NEW WALLS IN OPTICAL SALES SHALL HAVE 112" <br />PLYWOOD TO UNDER 1/2" GYPSUM BOARD. <br />14. PATCH AND REPAIR ALL WALL AREAS TO MATCH <br />ADJACENT SURFACES AND FINISHES. NEW WALL <br />SURFACES IN OFFICES TO RECEIVE MATCHING <br />ORANGE PEEL TEXTURE IF EXISTING. <br />15. INSTALL BASE AFTER INSTALLATIONS OF OWNER <br />FURNISHED CABINETS. <br />16. RELOCATE EXISTING PAPER TOWEL AND SOAP <br />DISPENSERS. <br />17. PAINT ALL HOLLOW METAL DOORS AND FRAMES P206 <br />INCLUDING DOCTORS AREA. <br />18. ALL WOOD MATERIAL SHOWN IN DETAILS ON THIS SHEET <br />SHALL BE FIRE RETARDANT TREATED WOOD (FRTW) IN <br />ACCORDANCE WITH INTERNATIONAL BUILDING CODE <br />SECTION 603.1. <br />THIS INCLUDES ALL REFERENCES TO "BLOCKING", <br />"NAILERS", "PLYWOOD", "SHEATHING", AND IF <br />APPLICABLE "WOOD STUDS". <br />19. DO NOT DISTURB / MOVE DOCTORS EQUIPMENT IN <br />EXAM / PRETEST. CAREFULLY PAINT AROUND AND DO <br />NOT REPLACE FLOOR TILE THAT WOULD DISTURB <br />DOCTORS EQUIPMENT. <br />20. PROVIDE ADEQUATE PROTECTION FOR EQUIPMENT. <br />DEMOLITION NOTES <br />1. ALL WALL COVERING TO BE REMOVED FROM <br />EXISTING WALLS. PATCH AND REPAIR ALL <br />GYPSUM BOARD SURFACES TO MATCH ADJACENT <br />AND READY TO RECEIVE FINISHES. <br />2. REMOVE ALL ELECTRICAL OUTLETS ABOVE <br />EXISTING SLAT WALL. REMOVE OUTLET BOX, <br />CONDUIT, AND ELECTRICAL WIRE BACK TO <br />NEAREST J-BOX. CAP WIRE AT J-BOX. <br />PATCH AND REPAIR WALL TO MATCH ADJACENT. <br />mLLwz �LLp Y <br />cn <br />W <br />Off"—��a OW�f-W <br />LLpH�aa>�zoz <br />Z�Z00 <br />W�W <br />a- W O O W 2 O 6 N <br />Ow <br />} ax ord3 <br />z <br />(LLL��ooW�W <br />3wWoww," 2� <br />z@c�Nw5w.W O <br />OcyU�CZ} <br />1-OW�-1W�tA <br />D <br />WWO <br />wmZO WV W U <br />a<ZWLLwWaozgQ(�ao <br />co <br />mZogOF= �WO�m <br />H <br />z <br />J <br />D <br />U) <br />z <br />O <br />v <br />w <br />co <br />a <br />0) <br />OD <br />� <br />0 0�cn <br />"' <br />0 0 <br />U LL- <br />C%) _j N <br />o <br />O <br />�2Of <br />o <br />a <br />ao <br />" Z <br />c-4 <br />o <br />-.J w <br />T <br />1mF_ <br />W <br />N "' co <br />ti <br />w <br />in <br />z <br />m <br />O <br />i <br />ISSUE BLOCK <br />1 <br />ADD1 <br />01/27/21 <br />2 <br />ADD3 <br />02/26/21 <br />3 <br />CCD4 <br />06/21/21 <br />4 <br />CCD5 <br />08/16/21 <br />CHECKED BY: <br />RD <br />DRAWN BY: <br />MUMB <br />PROTO CYCLE: <br />09/25/20 <br />DOCUMENT DATE: <br />11/06/20 <br />08/16/21 <br />VISION <br />CENTER <br />PLANS AND <br />DETAILS <br />SHEET: <br />vc1 <br />8 <br />