Laserfiche WebLink
SHOP DRAWINGS <br />EXTERIOR WALL <br />1/2" WIDE MOUTH <br />TOP BEAM CLAMP <br />ATTACHED WITHIN <br />3" OF JOIST GIRDER <br />PANEL POINT <br />7� TRAP <br />J FFERY D. BURNHAM <br />#83153100012006 <br />U-BOLT STYLE STRAP <br />RESTRAINED WITH MINIMUM <br />3/8" FENDER WASHER, <br />LOCK WASHER, AND NUTS <br />JOIST GIRDER <br />-1/2" TOP BEAM CLAMP ATTACHED <br />WITHIN 3" OF PANEL POINT <br />-ROOF DECK <br />-1/2" ALL THREAD ROD <br />-1/2" FENDER WASHER AND NUT <br />ON TOP AND BOTTOM OF ANGLE <br />TYP <br />FOR 8" MAIN USE 4 x 4 x 1 /4 <br />ANGLE DRILLED WITH MAXIMUM <br />9/16" HOLES (MAXIMUM 6 FT <br />SPAN ALLOWED) INSTALL ON <br />EVERY JOIST OR MAXIMUM 10'-0" <br />SPACING. <br />FOR 6" MAIN USE 3 x 3 x 5/16 <br />ANGLE DRILLED WITH MAXIMUM <br />9/16" HOLES (MAXIMUM 6 FT <br />SPAN ALLOWED) INSTALL ON <br />EVERY JOIST OR MAXIMUM 10'-0" <br />SPACING. <br />FOR 4"MAIN USE 3x2x1/4 <br />ANGLE DRILLED WITH MAXIMUM <br />7/16" HOLES (MAXIMUM 6 FT <br />SPAN ALLOWED) INSTALL ON <br />EVERY OTHER JOIST OR MAXIMUM <br />12'-0" SPACING. <br />PIPE SUPPORT <br />10.30.07 F30 <br />TRUSS GIRDER <br />GROCERY <br />STORAGE <br />FREEZER SEC <br />NTS 10.30.07 <br />ROOF JOISTS <br />.DROP FROM <br />OVERHEAD <br />PIPING <br />LIGHTS <br />CONDENSER <br />DRY CONCEALED <br />PENDENT SPRINKLER <br />FREEZER/COOLER <br />)N <br />F27-1 <br />UPRIGHT — <br />SPRINKLER <br />SALES <br />NOTE: COORDINATE <br />EXACT LOCATION OF <br />SPRINKLERS AT <br />COOLERS/FREEZERS <br />WITH LIGHTS, <br />EVAPORATORS AND <br />OTHER <br />OBSTRUCTIONS. <br />NOTE THAT FINAL <br />LIGHT AND <br />EVAPORATOR <br />LOCATIONS MAY <br />DIFFER FROM THOSE <br />SHOWN ON PLANS <br />1" PLUG <br />w <br />z <br />0 <br />N <br />AUXILIARY <br />NTS 10.30.07 <br />SPRINKLER MAIN <br />1" SHOULDER NIPPLE <br />1" GLOBE VALVE <br />CHAIN -HUNG SIGNAGE <br />MUST BE VISIBLE AT ALL <br />AREAS <br />RAIN <br />CONTRACTOR TO PROVIDE COVERAGE <br />BELOW ALL RTU DROP BOXES WHICH <br />EXCEED 4 FT 1N WIDTH. <br />APROXIMATELY 10. REF 1-FP1 <br />2" BRANCH LINE TY <br />CONNECT TO EXISTIt <br />2" BRANCH LINE TY <br />PIPE HANGE <br />MINIMUM 1" <br />SUPPLY TO <br />SPRINKLERS <br />TU SPRIW <br />5 TS 10.30.07 <br />PATCH PROCEDURE <br />1. ATTACH FIRMLY (WITH SHEET METAL SCREWS OR EQUIVALENT) A PIECE OF <br />KYSOR COOLER/FREEZER METAL SKIN, SHEET METAL OR EQUIVALENT MATERIAL <br />SIZED SLIGHTLY LARGER THAN THE HOLE TO BE PATCHED TO THE INSIDE OF <br />THE COOLER/FREEZER. <br />2. FROM THE TOP OF THE COOLER/FREEZER, FILL HOLE(S) TO BE PATCHED <br />COMPLETELY WITH THE EXPANSION FOAM. ALLOW THE FOAM TO COMPLETELY <br />DRY. <br />3. TRIM OFF EXCESS FOAM FLUSH WITH TOP OF COOLER/FREEZER. <br />4. ATTACH FIRMLY (WITH SHEET METAL SCREWS OR EQUIVALENT) A PIECE OF <br />KYSOR COOLER/FREEZER METAL SKIN, SHEET METAL OR EQUIVALENT MATERIAL <br />SIZED SLIGHTLY LARGER THAN THE HOLE, THAT IS NOW FILLED WITH THE <br />EXPANDED FOAM, TO THE OUTSIDE/TOP OF THE COOLER/FREEZER. <br />SHEET METAL OR <br />COOLER/FREEZER PANEL SKIN <br />FREEZER/COOLER <br />EXPANSION FOAM —� ROOF (EXISTING) <br />SHEET METAL--' �—FREEZER/COOLER <br />SCREWS CEILING (EXISTING) <br />"--SHEET METAL OR <br />COOLER/FREEZER PANEL SKIN <br />COOLER FREEZER SPRINKLER �PENET� <br />2 NTS <br />SUPPLY AND RETURN AIR <br />PLENUMS FROM ROOFTOP <br />UNIT <br />ROOF DECK <br />JOIST <br />LE COUPLING <br />urr_wn i 3rmrvnLLn i v mHTCH <br />SPRINKLER TYPE AT ROOF DECK <br />R DROP <br />F21 <br />HANG 4 AND 6 INCH PIPE WITHIN 3 INCHES OF PANEL POINT <br />PIPE 3 INCH AND SMALLER NOT REQUIRED TO BE WITHIN 3 <br />INCHES OF PANEL POINT <br />FOR 6 AND 8 INCH PIPE, USE THRU BOLT CONNECTION <br />WHERE POSSIBLE. USE TRAPEZE HANGER WHERE <br />JOIST PANEL POINTS TYP JOIST WEB CONFLICTS WITH THRU BOLT <br />6" <br />\ M-DECK TYP <br />ciao*�71e1� <br />6 INCH AND SMALLER PIPE <br />TO HORD <br />OF JOMT T' <br />`-MAINTAIN VISIBLE CLEARANCE BETWEEN <br />PIPE AND JOIST MEMBERS TYP <br />4, 6 AND 8 INCH PIPE 8 INCH PIPE <br />MAXIMUM HANGER SPACING FOR PIPING PERPENDICULAR TO JOISTS <br />BEAM CLAMP <br />THRU-BOLT <br />BEAM CLAMP <br />NOT TRAPEZED <br />NOT TRAPEZED <br />TRAPEZED <br />4" PIPE EVERY 12'-0" <br />4" PIPE EVERY 12'-0" <br />4" PIPE <br />EVERY OTHER JOIST <br />EVERY OTHER JOIST <br />NOT NECESSARY <br />6" PIPE EVERY 6'-0" <br />6" PIPE EVERY 12'-0" <br />6" PIPE <br />EVERY JOIST <br />EVERY OTHER JOIST <br />NOT NECESSARY <br />8" PIPE <br />8" PIPE EVERY 6'-0" <br />8" PIPE EVERY 6'-0" <br />NOT ALLOWED <br />EVERY JOIST <br />EVERY JOIST <br />PIPE RUNNING PERPENDICULAR TO JOISTS <br />6" <br />1/4"x2"x2" SQUARE WASHER & HEX NUT THRU BOLT TYP MAX <br />1/2- ALL THREAD ROD <br />I <br />FENDER WASHER & HEX NUT <br />3.5" X 2.5" X .25" ANGLE <br />TRAPEZE REQ'D FOR 6" MAINS <br />4" X 4" X .25" ANGLE <br />TRAPEZE REQ'D FOR 8" MAINS <br />TOP CHORD OF JOIST TYP <br />ONE OPEN JOIST BAY <br />MINIMUM BETWEEN <br />TRAPEZE HANGERS <br />12" DO NOT HANG 2 OR MORE <br />MIN MAINS 4" OR LARGER BETWEEN <br />THE SAME JOIST SPACE <br />MAXIMUM HANGER SPACING FOR PIPES PARALLEL TO JOISTS <br />4 PIPE EVERY 12'-0 <br />6 PIPE EVERY 12'-0 <br />8" PIPE EVERY 12'-0" <br />NOT TRAPEZED <br />TRAPEZED <br />TRAPEZED <br />BEAM CLAMP <br />THRU BOLT <br />THRU BOLT <br />PIPE RUNNING PARALLEL TO JOIST <br />CONTRACTOR MAY SUBSTITUTE ANGLE IRON TRAPEZE <br />MEMBER WITH PIPE MEMBER. SIZE PIPE MEMBER IN <br />ACCORDANCE WITH NFPA-13 AND MAINTAIN 12 INCH <br />MAXIMUM DEFLECTOR DISTANCE <br />12" <br />MIN <br />n u% <br />`O O a p3 <br />O V <br />� a .N <br />_= <br />f1 O N <br />.- r 2 <br />O <br />a <br />a) c 0 <br />0 <br />2 N E 1L <br />4) <br />H O <br />OL 75 2 i= <br />s 0 N <br />a U — <br />LL <br />!r co <br />m. <br />cTs E <br />c �a) <br />cn Q � <br />.; <br />im� <br />•> <br />W <br />.c <br />I-LLOr <br />L a) <br />O a m <br />\ 4— ty <br />13)0 0 a <br />=a�a <br />rn � <br />M <br />co r r <br />vJ 9 <br />N Co <br />90 co co <br />°o <br />r Qai co <br />CD <br />c <br />N a <br />o <br />L <br />c o <br />a 0 <br />0 <br />z <br />�. <br />d <br />o <br />N <br />J <br />> <br />2z <br />o <br />2a <br />z <br />a5 <br />a <br />U- <br />a <br />m <br />a) <br />U- <br />a? a <br />u- to <br />U <br />o <br />in <br />c <br />ca <br />@1 <br />�0 <br />`' <br />2 <br />Co <br />0 <br />_0 <br />2 <br />ad• <br />Z, <br />.00 m <br />0 o <br />C <br />M <br />cn <br />J <br />is <br />U <br />2 <br />a`) <br />co <br />o <br />V) <br />_ <br />o <br />cu <br />0 _ <br />0 <br />coas <br />Co '_ <br />a <br />= <br />2 <br />J 8 <br />a� <br />a)W <br />a> <br />c <br />2 <br />a <br />E <br />F- 0 <br />a <br />0 <br />a o <br />o m <br />_c m <br />a <br />c <br />¢ii <br />- <br />¢0� <br />m � <br />- <br />¢ <br />co <br />_ <br />r <br />N <br />m <br />.4 <br />uti <br />o <br />c <br />0 <br />0 <br />U- <br />m <br />a <br />a. <br />5 <br />c <br />v <br />o <br />a, <br />to <br />°� <br />o <br />o <br />« <br />c <br />0. <br />o <br />"a•2 <br />Q <br /><a <br />a <br />0> <br />u- <br />o <br />c> <br />c= <br />c <br />j <br />v <br />a <br />0 <br />m <br />cc <br />0 <br />v <br />G <br />m <br />0 <br />N <br />oa <br />a <br />a-'� <br />M <br />c <br />= <br />w <br />0 <br />w <br />o <br />� <br />0 <br />at <br />0 <br />E . �, o <br />N U r <br />NOTE: DO NOT SUPPORT SPRINKLER PIPING FROM BOTTOM CHORD OF BAR JOISTS I 1 1+ <br />I <br />PIPESUPPORT 4 NTS 10.30.07 F027 <br />OPTION "A" INSTALLATION PROCEDURE <br />I. CORE DRILL 2 1/2" DIAMETER HOLE IN THE FREEZER/COOLER INSULATED <br />CEILING PANEL. LOCATE HOLE AND REQUIRED SPRINKLER PROTECTION <br />IN ACCORDANCE WITH NFPA 13 OBSTRUCTION CRITERIA (SSP TYPE <br />SPRINKLERS). MAINTAIN 6" CLEARANCE FROM COOLER SEAMS. <br />2. INSTALL DRY PENDENT SPRINKLER PER MANUFACTURERS INSTALLATION <br />REQUIREMENTS. <br />3. COMPLETELY FILL ANNULAR CEILING OPENING BETWEEN THE ESCUTCHEON AND <br />TOP OF CEILING PANEL WITH OPEN -CELL POLYETHYLENE FOAM BACKER ROD. <br />EXPANDED FOAM IS NOT PERMITTED. <br />4. INJECT DOW CORNING 739 PLASTIC ADHESIVE SEALANT INTO AND AROUND <br />THE TOP OF THE FREEZER/COOLER CEILING CORE OPENING IN ACCORDANCE <br />WITH SEALANT MANUFACTURERS INSTRUCTIONS <br />UTILIZE THESE HANGING METHODS FOR ALL SPRINKLER <br />PIPING. SPACE TRAPEZE HANGERS IN ACCORDANCE <br />WITH SCHEDULE. LOCATE HANGERS WITHIN 3 INCHES <br />OF JOIST PANEL POINTS U.N.O. <br />VPTION "B" INSTALLATION PROCEDUR <br />1. C DRILL 2 1/2" DIAMETER HOLE IN THE FREEZER/COOLER INSUL D <br />CEIL G PANEL FROM BELOW. LOCATE HOLE AND REQUIRED SPRINK R <br />PRO TION IN ACCORDANCE WITH NFPA 13 OBSTRUCTION CRITERI (SSP <br />TYPE RINKLERS), MAINTAIN 6" CLEARANCE FROM COOLER SE S. <br />2. INSTALL CO DRY PENDENT SPRINKLER PER MANUFACTURE INSTALLATION <br />REQUIREM TS. INSERT BOOT PRIOR TO MAKE-UP WITH PI G. <br />3. COMPLETELY EAL INTERFACE BETWEEN BOOT FLANGE A TOP OF <br />FREEZER/CO0 R PANEL WITH ADHESIVE PROVIDED WI BOOT IN <br />ACCORDANCE H MANUFACTURERS INSTRUCTIONS. J <br />c <br />4. APPLY STRAP TIE ON BOOT AROUND DRY SPRI ER BARREL PER I j •2 <br />MANUFACTURERS IN TRUCTIONS. <br />Z aad aQa <br />0 <br />U <br />� <br />v <br />SUPPLY FROM WET <br />W <br />co <br />N <br />0 <br />-� <br />a <br />CD <br />t- <br />z <br />T <br />m <br />PIPE SPRINKLER SYSTEM <br />O <br />Lb <br />TEE WITH PLUG <br />W <br />IY <br />uL <br />c <br />m <br />1" DRY 2 NYLON STRAP TIES <br />m <br />Z <br />m <br />�+ <br />SPRINKLER DROP (INSTALL OPPOSITE DIRECTIONS)CL <br />ccl <br />3 <br />of <br />o <br />TYCO RUBBER SEAL co CL 0 <br />o f <br />v <br />o <br />ton <br />o <br />CL <br />a <br />BOOT MODEL DSB-2 z w <br />FREEZER/COOLER EALANT PER BOOT r <br />CEILING NUFACTURER z <br />co <br />a <br />z <br />SPRINKLER CUP ---GLOBE MODEL GL5681/ /RINKCUP —� ��- TYCO MODEL 3555 <br />TYCO MODEL TY3555/ CONCEALED 20 DRY <br />COVER PLATE VICTAULIC V3301 PENDENT SPRINKL <br />2 CONCEALED 200'F DRY TE 2j" (NO SUBSTITUTIONS <br />PENDENT SPRINKLER <br />OPTION A (NO SUBSTITUTIONS) OPTION B <br />NOTE: CONTRACTOR TO SEAL DRY PENDENT SPRINKLERS AT FREEZER/COOLER USING ONE OF THE OPTIONS ABOVE. NO OTHER SEALANTS ARE PERMITTED. <br />A T 10 N PATCH FREEZER COOLER DRY PENDENT SPRINKLER <br />MF197 NTS 01.28.11 F19 <br />Q <br />W <br />p <br />O <br />r- <br />U <br />Z <br />w <br />=) <br />W <br />_i <br />a <br />p <br />�> <br />Ir <br />W <br />J <br />a <br />>- <br />3: <br />rY <br />} <br />_ <br />C <br />:p <br />> <br />0 <br />0 <br />Z <br />a <br />0 <br />¢ <br />0 <br />cc <br />o <br />_ <br />uj N <br />m <br />J <br />= <br />O <br />W <br />Ix <br />!L <br />m <br />� <br />00 <br />_j <br />CL <br />Q <br />Q <br />p <br />W <br />O <br />� <br />N <br />Z <br />V <br />CC <br />0 <br />Q <br />DWG <br />FP3 <br />