Laserfiche WebLink
3 <br />cn <br />0 <br />r- <br />0 <br />I <br />In <br />Z <br />0 <br />1— <br />U <br />w <br />0 <br />z <br />Q <br />V) <br />z <br />0 <br />Q <br />> <br />w <br />J <br />w <br />c� <br />z <br />0 <br />m <br />N <br />Q <br />I <br />0 <br />U) <br />0 <br />0 <br />U <br />U <br />J <br />I <br />(o <br />0 <br />0 <br />a <br />W <br />N <br />0 <br />0 <br />r <br />0 <br />a <br />a� <br />N <br />w <br />V) <br />E <br />o <br />�n <br />oN <br />w <br />V) U <br />I co <br />E <br />0 <br />�a- <br />o- <br />0 <br />I a�i <br />a <br />N �- <br />0 <br />�E <br />_ o <br />1 �RlGHT �ELEVATION <br />% J J 1 "=20'-O" <br />F <br />�J <br />10 <br />REAR ELEVATI( <br />"—on' not <br />FRONT ELEVATION <br />1 20'-O" <br />LEFT ELEVATION. <br />1 -20'-0" <br />6 NOT USED <br />NTS <br />5 NOT USED <br />NTS <br />15'- 4" <br />10'-7" <br />WHITE PLASTIC LETTERS 1 <br />PLASTIC LETTERS TO MATCH <br />SW #6904 "GUSTO GOLD" <br />�66.76 SF <br />PAINT DOOR AND FRAME <br />P126(U), REF 5-A1 <br />FULL BED OF ML <br />COMPONENT SEA <br />PERIMETER OF C <br />SIGN INSTALLED <br />INSTALL LETTER <br />PRIOR TO INSTAI <br />BY SIGN INSTALL <br />FLEX CONDUIT S <br />WITH LETTERS 0 <br />THROUGH ENTIRE <br />BY SIGN INSTALL <br />INDIVIDUAL PLAS <br />ILLUMINATED CHI <br />LETTERS BY SIGI <br />INSTALL LETTER <br />W/ SET SCREWS <br />SIGN INSTALLER <br />2 <br />A2 <br />PRE MOLDED PIPE FLASHING. ATTACH <br />PER ROOFING MFR RECOMMENDATIONS <br />BY BUILDING GENERAL CONTRACTOR <br />SEALANT ALL AROUND BY <br />BUILDING GENERAL CONTRACTOR <br />WATERPROOFING <br />MEMBRANE OVER CMU <br />CONTINUOUS UNISTRUT PROVIDED BY <br />GENERAL CONTRACTOR. ATTACH AT 48" <br />OC WITH 6x6 STEEL PLATE WITH (4) <br />1/2" MASONRY EXPANSION ANCHORS. <br />SET PLATE IN FULL BED OF SEALANT. <br />NOTE, UNISTRUT MAY BE ABOVE OR <br />BELOW WIRE PENETRATION <br />4" X 4" JUNCTION BOX. ATTACH TO <br />UNISTRUT BY BUILDING GENERAL <br />CONTRACTOR <br />LOCATE CONDUIT PENETRATION 4'-0" <br />MAX FROM UNISTRUT. PROVIDE ONLY <br />ONE ROOF PENETRATION FOR ALL <br />WHIPS. <br />LOCATE IMPACT ANCHORS AND <br />WIRING/CONDUIT PENETRATIONS PER <br />SIGN ATTACHMENT TEMPLATE <br />PROVIDED BY WALMART <br />SIGN ATTACHMENT <br />3 A 11 /2"=1' <br />WATERPROOFING MEMBRANE BY BUILDING GENERAL CONTRACTOR <br />FLEX CONDUIT SUPPLIED CONTINUOUS UNISTRUT. ATTACH AT 48" OC WITH 6x6 STEEL PLATE <br />WITH LETTERS CONTINUOUS WITH (4) 1 /2" MASONRY EXPANSION ANCHORS. SET PLATE IN FULL <br />THROUGH ENTIRE PARAPET BED OF SEALANT. NOTE, UNISTRUT MAY BE ABOVE OR BELOW WIRE <br />BY SIGN INSTALLED PENETRATION BY BUILDING GENERAL CONTRACTOR <br />0 4" X 4" JUNCTION BOX. ATTACH TO UNISTRUT BY <br />BUILDING GENERAL CONTRACTOR <br />FULL BED OF MULTI- PRE MOLDED PIPE FLASHING. ATTACH PER ROOFING MFR <br />COMPONENT SEALANT AT RECOMMENDATIONS BY BUILDING GENERAL CONTRACTOR <br />PERIMETER OF CONDUIT BY <br />SIGN INSTALLED <br />INSTALL LETTER BACK <br />PRIOR TO INSTALLATION <br />BY SIGN INSTALLER <br />3/4" LIQUID TIGHT FLEXIBLE METAL <br />CONDUIT BY BUILDING GENERAL <br />CONTRACTOR <br />SEALANT ALL AROUND BY BUILDING <br />GENERAL CONTRACTOR <br />ROOFING SYSTEM <br />INDIVIDUAL PLASTIC LOCATE CONDUIT PENETRATION 4'-0" <br />ILLUMINATED CHANNEL MAX FROM UNISTRUT. PROVIDE ONLY <br />LETTERS BY SIGN SUPPLIER ONE ROOF PENETRATION FOR ALL <br />WHIPS. <br />LOCATE IMPACT ANCHORS AND <br />INSTALL LETTER FACES WIRING/CONDUIT PENETRATIONS PER <br />W/ SET SCREWS, TYP BY SIGN ATTACHMENT TEMPLATE <br />SIGN INSTALLER PROVIDED BY WALMART <br />9 NOT USED <br />NTS <br />$ NOT USED <br />NTS <br />SIGN MOUNTING <br />LOCATION (TYP) FIELD <br />VERIFY EXACT LOCATIONS <br />ROOF LINE <br />JOIST BEARING <br />ELEVATION LINE <br />PICKUP <br />1 /4" = V-0" <br />C&M <br />1 50-4fF <br />NOTE: <br />ALL SIGN PENETRATIONS ABOVE <br />ROOF LEVEL MUST BE A CLEAR <br />MINIMUM OF 8" ABOVE DECK <br />ELECTRICAL PENETRATIONS (TYP) <br />FIELD VERIFY EXACT LOCATIONS <br />REF BLDG ELEVATIONSjk <br />CENTER OF SIGNMV <br />NOTE TO SIGN INSTALLED: <br />ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED. IF MOUNTING THROUGH <br />PRIMARY HOLE IS OBSTRUCTED BY REBAR, METAL STUDS, CHANNELS, OR OTHER <br />MISC METAL, SEAL PRIMARY HOLE IN SIGN CAN AND MOUNT THROUGH THE <br />NEAREST ALTERNATE MOUNTING HOLE. PRIMARY HOLES ARE INDICATED WITH <br />PREDRILLED HOLES THROUGH WASHERS. ALTERNATE HOLES ARE INDICATED <br />WITH WASHERS ONLY OR ARE OTHERWISE MARKED. <br />TING DIAGRAM 2'67 <br />PAINT TRANSITION <br />LINE <br />c� <br />CV <br />N <br />20'-0" <br />2'-6" HIGH <br />ILLUMINATED SIGN <br />REF 4-A2.0 <br />PAINT TRANSITION <br />LINE <br />EXISTING LIQUOR <br />BOX <br />1 BUILDING PICKUP SIGNAGE 2'6 PREFERRED r SIGN ATTACHMENT C BUILDING SIDE ELEVATION n BUILDING FRONT ELEVATION <br />Y �/z' _ 1'_0" 1 1/2'*=l'-O" <br />�3)-2 <br />�rWJ <br />V <br />V d7 0 <br />C) 0 0 <br />0 <br />E <br />O <br />u') CO CO <br />t M 00 <br />CO <br />00 <br />CU <br />O ti <br />Q — 00 <br />N Lo <br />t-- <br />00 <br />V <br />O <br />— <br />_ <br />L It co <br />CC) <br />ci <br />0 :2 (LS O <br />CA <br />cn <br />V <br />0 0 <br />C <br />C m L <br />mt cu <br />m <br />0)cm <br />E o <br />U) <br />•y <br />m U) <br />0 <br />� <br />N M :3 <br />3 <br />L tf F_ <br />a <br />0 <br />0 <br />caco <br />y <br />U <br />W o F r <br />w � � ola <br />w Z-*gFw Zyz <br />X WI.- 0 'awUo<VU <br />Of 0. cn v XT=Z3wo,w <br />O aN z<mN�Ww>-zcn(x <br />w o cr <br />v, NhIaVOOF wz W wx <br />Z QLD'W <br />O 3WI�JWmJ-fn-wmz oZ <br />F- ONZ—m 7V Z Q <br />9SiQ< nm!=wROwFW <br />J QaNFDoQ=ZZLLmwoN <br />cr <br />C3om� w Obio <br />- N WaWFZL"WgiW0�WWm <br />cn <br />N <br />H <br />z <br />Q <br />H <br />J <br />N <br />z <br />O <br />U <br />00 <br />0 0 <br />0 <br />0 0 <br />� <br />Ln <br />N <br />N <br />CD <br />U <br />O <br />O <br />0 <br />Z <br />o <br />LiJ <br />c4 <br />ocv <br />o <br />cc <br />N <br />a <br />w <br />z <br />ISSUE BLOCK <br />CHECKED BY: <br />RWO <br />DRAWN BY: <br />LMD/CRE <br />PROTO: <br />LCC <br />PROTO CYCLE: <br />01 /31 /17 <br />DOCUMENT DATE: <br />02/16/17 <br />RECORD DRAWINGS NOTICE <br />THE RECORD COPY OF THIS DRAWING <br />IS ON FILE AT THE OFFICES OF SGA <br />DESIGN GROUP. THIS ELECTRONIC <br />DOCUMENT IS RELEASED FOR THE <br />PURPOSES OF REFERENCE, <br />COORDINATION, AND/OR FACILITY <br />MANAGEMENT. THIS DRAWING SHALL <br />NOT BE CONSIDERED FINAL OR <br />COMPLETE UNLESS IT IS SIGNED AND <br />SEALED BY THE ARCHITECT. <br />'C�•O FFC pR <br />P.••' Mq � <br />:Q <br />0. <br />-33 :�y AR96472 ZC'� <br />7/17 <br />BUILDING <br />ELEVATIONS <br />AND <br />SECTION S <br />SHEET: <br />A 2 <br />