SPECIAL INSPECTIONS <br />NOTE: ALL INSPECTIONS SHALL BE PERFORMED BY A QUALIFIED, CERTIFIED THIRD -PARTY TESTING AND <br />INSPECTION AGENCY, EMPLOYED BY THE OWNER, FOR THE FOLLOWING SCOPE IF WORK. ALL <br />INSPECTIONS AND TESTING SHALL MEET OR EXCEED THE REQUIREMENTS OF IBC CHAPTER 17 OR THE <br />AUTHORITY HAVING JURISDICTION (WHICHEVER IS MORE STRINGENT). REFER TO CHAPTER 17 OF THE <br />INTERNATIONAL BUILDING CODE FOR DETAILED DESCRIPTION OF REQUIREMENTS. REFER TO THE <br />APPLICABLE SPECIFICATION SECTIONS FOR SPECIFIC TESTING AND INSPECTION REQUIREMENTS. <br />PERIODIC SPECIAL INSPECTIONS: <br />STEEL <br />1. MATERIAL VERIFICATION OF HIGH STRENGTH BOLTS, NUTS, AND WASHERS <br />2. BOLTED FASTENER ASSEMBLIES OF SUITABLE CONDITION PLACED IN ALL HOLES AND WASHERS <br />POSITIONED AS REQUIRED <br />3. ALL JOINTS BROUGHT TO THE SNUG TIGHT CONDITION <br />4. INSPECTION OF STEEL FRAME BOLTED JOINT DETAILS FOR COMPLIANCE WITH APPROVED <br />CONSTRUCTION DOCUMENTS <br />CONCRETE <br />1. INSPECTION OF REINFORCING STEEL AND PLACEMENT <br />2. VERIFYING USE OF DESIGN MIX COINCIDING WITH MATERIAL SPECIFIED IN THE CONSTRUCTION <br />DOCUMENTS <br />POST -INSTALLED CONCRETE ANCHORS <br />1. PERIODICALLY VERIFY AND INSPECT THE FOLLOWING FOR EACH ANCHOR <br />A. GENERAL COMPLIANCE WITH MANUFACTURER'S PUBLISHED INSTRUCTIONS <br />B. PROJECT NAME AND DESCRIPTION <br />C. ADHESIVE EXPIRATION DATE FOR ADHESIVE ANCHORS <br />D. HOLE DIAMETER, DEPTH, LOCATION <br />E. ANCHOR DIAMETER, LENGTH, AND STEEL GRADE <br />F. ANCHOR EMBEDMENT AND SPACING <br />CONTINUOUS SPECIAL INSPECTIONS <br />SOILS AND CAST -IN -PLACE DEEP FOUNDATIONS <br />1. OBSERVE DRILLING OPERATIONS AND MAINTAIN COMPLETE AND ACCURATE RECORDS OF EACH <br />ELEMENT <br />2. VERIFY PLACEMENT LOCATIONS AND PLUMBNESS, CONFIRM ELEMENT DIAMETERS, BELL DIAMETERS (IF <br />APPLICABLE), LENGTHS, EMBEDMENT INTO BEDROCK (IF APPLICABLE) AND ADEQUATE END BEARING <br />CAPACITY. RECORD CONCRETE VOLUMES <br />3. VERIFY USE OF PROPER MATERIALS, DENSITIES, AND LIFT THICKNESSES DURING PLACEMENT AND <br />COMPACTION OF ALL FILL. <br />CONCRETE <br />1. SAMPLE FRESH CONCRETE FOR STRENGTH TESTS AND PERFORM SLUMP AND AIR CONTENT TESTS. <br />DETERMINE THE TEMPERATURE OF FRESH CONCRETE AT THE TIME SPECIMENS ARE MADE FOR <br />STRENGTH TEST. 1-SET OF CONCRETE CYLINDERS FOR A 28-DAY COMPRESSIVE TEST IS AN <br />ACCEPTABLE FREQUENCY. <br />2. INSPECTION OF CONCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES <br />CERTIFICATION: DOCUMENT FINAL REPORT OF SPECIAL INSPECTIONS IN ACCORDANCE WITH CHAPTER <br />17 OF THE IBC. SUBMIT ALL REPORTS TO OWNER, ARCHITECT, AND AUTHORITY HAVING JURISDICTION <br />AS REQUIRED. REFERENCE SPECIFICATIONS FOR ADDITIONAL DOCUMENTATION REQUIREMENTS <br />CL OF COLUMN AND FTG <br />CL <br />CANOPY DESIGN LOADS <br />A. BUILDING CODE <br />1. CANOPY GRAVITY LOADS <br />A. DEAD LOADS <br />B. ROOF LIVE LOADS <br />C. GROUND SNOW LOAD <br />2. CANOPY LATERAL LOADS <br />A. WIND LOADS <br />1. ULTIMATE WIND SPEED <br />2. BASIC WIND SPEED (SERVICE) <br />3. WIND EXPOSURE CATEGORY <br />4. RISK CATEGORY <br />5. INTERNAL PRESSURE COEFFICIENT (GCpi) <br />B. SEISMIC LOADS <br />1. RISK CATEGORY <br />2. SEISMIC IMPORTANCE FACTOR (le) <br />3. SEISMIC COEFFICIENT (SS) <br />4. SEISMIC COEFFICIENT (S1) <br />5. SITE CLASS <br />6. SEISMIC COEFFICIENT (SDS) <br />7. SEISMIC COEFFICIENT (SD1) <br />8. SEISMIC DESIGN CATEGORY <br />9. BASIC SEISMIC FORCE RESISTING SYSTEM <br />10. DESIGN BASE SHEAR (V) <br />11. SEISMIC RESPONSE COEFFICIENT (Cs) <br />12. RESPONSE MODIFICATION COEFFICIENT <br />13. ANALYSIS PROCEDURE <br />LOAD COMBINATIONS WITH SNOW LOAD SHALL ALSO INCLUDE LOADS FROM <br />HIGH -LOW ROOF DRIFTING FROM MAIN BUILDING ROOF, PER CODE. <br />24' - 0" <br />2014 FLORIDA BUI <br />PER CANOPY MANUF <br />PER CANOPY MANUF <br />0 PSF <br />140 MPH <br />110 MPH <br />PER CANOPY MANUF <br />PER CANOPY MANUF <br />PER CANOPY MANUF <br />PER CANOPY MANUFI <br />1.0 <br />PER CANOPY MANUF <br />PER CANOPY MANUF <br />PER CANOPY MANUF <br />PER CANOPY MANUF <br />PER CANOPY MANUF <br />24' - 0" <br />GENERAL NOTES <br />1.0 GENERAL <br />1.1 THE SIZE AND LOCATION OF PENETRATIONS THROUGH THE STRUCTURE FOR MECHANICAL, ELECTRICAL AND PLUMBING WORK SHALL <br />BE COORDINATED WITH THE APPROPRIATE CONTRACTOR(S). PENETRATIONS SHALL BE SUBJECT TO APPROVAL BY THE <br />ARCHITECT/ENGINEER. PENETRATIONS SHALL BE THROUGH FOUNDATION STEMWALL OR 6" CLEAR BELOW FOOTING. STEP FOOTING AS <br />REQUIRED PER DETAILS. <br />1.2 THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ADEQUATE TEMPORARY SUPPORT AND STABILITY OF EXISTING STRUCTURE <br />DURING ALL PHASES OF CONSTRUCTION. <br />1.3 VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO FABRICATION OF STRUCTURAL ITEMS. IF ANY DISCREPANCIES ARE FOUND BETWEEN <br />WHAT IS SHOWN ON THE PLANS AND WHAT EXISTS IN THE FIELD, CONTACT THE WAL-MART CONSTRUCTION MANAGER TO DETERMINE <br />WHAT SHOULD BE DONE TO MATCH EXISTING CONDITIONS AS REQUIRED. BEGINNING OF CONSTRUCTION MEANS ACCEPTANCE OF <br />EXISTING CONDITIONS. <br />2.0 FOUNDATIONS AND SUBGRADE <br />2.1 FOOTING DESIGNS ARE BASED ON AN ASSUMED, NON -EXPANSIVE SOIL WITH A MAXIMUM NET ALLOWABLE SOIL BEARING PRESSURE OF <br />1,500 PSF WITH A MAXIMUM DIFFERENTIAL SETTLEMENT OF 1/2". CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING WHETHER <br />OR NOT SOILS MEETS THIS MINIMUM CRITERIA AND IF IT DOES NOT, SHALL NOTIFY THE ENGINEER OF RECORD. <br />2.2 EXTERIOR FOOTINGS SHALL BEAR AT OR BELOW MINIMUM BEARING DEPTH. MINIMUM BEARING DEPTH IS 12" BELOW ADJACENT <br />FINISHED GRADE. THICKENED SLAB EDGES FOR STOOPS, CANOPIES, ETC. SHALL BE 16" (UNO). <br />2.3 BELLING AT THE TOP OF PIERS SHALL BE AVOIDED. SHOULD BELLING OCCUR, SONOTUBES SHALL BE USED TO EXTEND THE PIER TO <br />THE PROPER ELEVATION. <br />2.4 CONCRETE SHALL BE POURED IN ALL PIER HOLES WITHIN 8 HOURS OF EXCAVATION. ANY ACCUMULATED WATER SHALL BE PUMPED <br />FROM THE PIER HOLES PRIOR TO CONRETE PLACEMENT. <br />2.5 DO NOT ALLOW STORED EXCAVATION MATERIAL TO DISRUPT PROPER DRAINAGE OF AREA. <br />2.6 DISPOSE OF EXCAVATED MATERIAL AS REQUIRED BY OWNER'S REPRESENTATIVE. <br />2.7 BEFORE OR CONCURRENT WITH THE EXCAVATION FOR THE FOUNDATIONS ADJACENT TO THE EXISTING BUILDING, PROVIDE ADEQUATE <br />SUPPORT TO THE SUBBASE AND SUBGRADE OF THE EXISTING SLAB AND FOUNDATIONS TO PREVENT UNDERMINING. <br />3.0 REINFORCED CONCRETE <br />3.1 MINIMUM COMPRESSIVE STRENGTH (fc) AT THE END OF 28 DAYS AND MAXIMUM WATER -CEMENT RATIO (w/c) SHALL BE AS FOLLOWS: <br />fc w/c ADDITIONAL REQUIREMENTS <br />A. STRUCTURAL CAST -IN -PLACE CONCRETE 3,000 PSI 0.50 SPECIFICATION SECTION 03310 <br />3.2 EXPOSURE CLASSIFICATION: NEGLIGIBLE <br />3.3 REINFORCING STEEL SHALL MEET ASTM SPECIFICATION A-615, LATEST REVISION. BARS SHALL BE GRADE 60. REINFORCING BARS <br />SHALL BE SPLICED A MINIMUM OF 48 BAR DIAMETERS OR 24 INCHES WHICHEVER IS GREATER, UNO. <br />3.4 REF ACI 318 LATEST EDITION FOR CONCRETE COVER, ACI 315 LATEST EDITION FOR DETAILING PRACTICES AND FABRICATION, AND ACI <br />301 LATEST EDITION FOR STANDARD PRACTICE FOR MIXING AND PLACING REINFORCED CONCRETE. <br />4.0 PRE -MANUFACTURED CANOPY <br />4.1 CANOPY ERECTOR SHALL PROVIDE TEMPORARY BRACING FOR THE ENTIRE CANOPY STRUCTURE UNTIL ALL STRUCTURE AND <br />CONNECTIONS ARE INSTALLED AND FUNCTIONING AS THE DESIGNED UNIT. <br />4.2 THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES OF <br />CONSTRUCTION SELECTED. <br />4.3 THE CANOPY ERECTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITIONS OF THE JOB SITE IN AND AROUND <br />THE CANOPY INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY. <br />4.4 ALL DETAILING, FABRICATION AND ERECTION SHALL CONFORM TO THE CURRENT EDITION OF THE AISC "CODE OF STANDARD PRACTICE <br />FOR STEEL BUILDINGS AND BRIDGES" OR AISI "COLD FORMED STEEL DESIGN MANUAL." <br />4.5 FIELD CONNECTIONS SHALL BE BOLTED EXCEPT WHERE WELDED CONNECTIONS ARE INDICATED ON THE MANUFACTURER'S <br />DRAWINGS. <br />4.6 ANCHOR BOLTS SHALL BE SET IN STRICT COMPLIANCE WITH THE MANUFACTURER'S SPECIFICATIONS. <br />4.7 WELDING SHALL BE IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY (AWS D1.1 & D1.3), LATEST REVISION. ELECTRODES SHALL <br />BE 70 KSI LOW HYDROGEN. <br />4.8 BOLTS FOR CANOPY CONNECTIONS SHALL BE ASTM A 325-N HIGH STRENGTH BOLTS INSTALLED PER MANUFACTURERS INSTALLATION <br />REQUIREMENTS. <br />4.9 MANUFACTURER SHALL DESIGN ALL CANOPY FRAMING, BASE PLATES, ANCHORAGE TO FOUNDATIONS, AND SUBSEQUENT <br />CONNECTIONS TO MEET THE DESIGN LOAD CRITERIA SHOWN. <br />4.10 STRUCTURAL DESIGN OF THE CANOPY SHALL BE PERFORMED BY AN ENGINEER LICENSED IN THE PROJECT STATE. <br />4.11 MANUFACTURER IS RESPONSIBLE FOR DESIGNING AND SUPPLYING ALL CONNECTIONS. <br />4.12 MANUFACTURER SHALL PROVIDE ALL CALCULATIONS AND DRAWINGS TO THE FOUNDATION ENGINEER FOR REVIEW. PRIOR TO THE <br />DRAWINGS BEING ISSUED FOR PERMIT. LOADS SHALL BE PROVIDED IN FORMAT SHOWN BELOW VALUES SHALL BE UNFACTORED. <br />4.13 MANUFACTURER SHALL PROVIDE SHOP DRAWINGS FOR REVIEW TO FOUNDATION ENGINEER PRIOR TO CONSTRUCTION. <br />SHEAR <br />LOAD <br />11W <br />VERTICAL <br />LOAD <br />"Poo <br />MOMENT <br />DEAD LOAD <br />O.OK <br />O.OK <br />O.OK <br />LIVE LOAD <br />O.OK <br />O.OK <br />O.OK <br />SNOW+DRIFT <br />O.OK <br />O.OK <br />O.OK <br />WIND <br />O.OK <br />O.OK <br />O.OK <br />SEISMIC <br />O.OK <br />O.OK <br />O.OK <br />I <br />I I <br />I I <br />I I <br />� I <br />f V P M <br />24' - 0" <br />F <br />ENTIRE SHEET ADDED <br />PER CCD #1 <br />10"x8" CANOPY COLUMN <br />SUPPLIED BY CANOPY MFR <br />BASE PLATE SUPPLIED BY CANOPY MFR <br />PROVIDE 1 12" NON -SHRINK <br />I <br />I I <br />WATERPROOF BASE PL, ANCHOR BOLTS, <br />GROUT BELOW COLUMN BASE <br />i <br />i AND COLUMN WITH ASPHALTIC MASTIC <br />PLATE AFTER ERECTION <br />- <br />BELOW FF EL <br />I <br />II <br />I <br />I <br />I <br />I <br />I <br />r-------------------------------------------------------------------------------------------------------------------------------- <br />I <br />I <br />------------------------ <br />-------------------- -� <br />I <br />I <br />I <br />I <br />REF CANOPY MFR <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />COL BRG EL <br />I <br />tV <br />I <br />POST -INSTALLED ANCHORS, <br />SUPPLIED BY CANOPY MFR <br />I <br />I <br />(COORDINATE LOCATION WITH <br />I <br />(3) #3 TIES IN TOP <br />CANOPY MFR) <br />5" OF PIER <br />9'A <br />O� <br />I <br />(7) #8 VERTICAL <br />I <br />NOTE: CONTRACTOR SHALL LOCATE AND <br />o SECTION <br />i <br />MARK ALL UTILITIES IN THE VICINITY OF <br />° <br />I <br />i <br />THE DRILLED PIERS PRIOR TO DRILLING. <br />NOTIFY THE ARCHITECT OF RECORD IF <br />LOCATIONS WILL INTERFERE WITH <br />PLACEMENT OF PIERS. <br />#3 HOOP TIES AT <br />PLACE VERTICAL <br />16" CC, TYP <br />BARS EQUALLY <br />o <br />ABOUT PIER <br />co <br />SECTION CIRCUMFERENCE <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />-------------------------------------------------------------------J <br />I <br />IL-------------------------------------------------------------------------------------------------------------------- <br />EDGE OF CANOPY ABOVE. <br />REF ARCH FOR CONFIGURATION. <br />NOTIFY ARCH/ENGINEER IF DESIGN <br />LOADS REQUIRE A CHANGE IN <br />CONFIGURATION <br />w w W3o w 0, <br />w � - <br />0 <br />z maw <u- <br />((u) z <br />1(1) T �a5 <br />a <br />O <br />z <br />00 d <br />O O U <br />0 0 `L <br />V/ 04 <br />N <br />Nco <br />O <br />J O <br />gigO o <br />Z04 <br />u � <br />O <br />Q <br />vV <br />W <br />N w <br />w <br />m <br />z <br />m <br />O <br />ISSUE BLOCK <br />1 104/07/171 CCD #1 <br />CHECKED BY: <br />DWBF <br />DRAWN BY: <br />EDR <br />PROTO CYCLE: <br />01/27/17 <br />DOCUMENT DATE: <br />02/16/17 <br />`��Q►�F S. Job, <br />� OF tv i <br />0 <br />4 <br />• +• ORIO:' <br />1101,111466 <br />2017.04.10 09:46:31-05'00' <br />CARRIE J. JOHNSON <br />ENGINEER OF RECORD LICENSE #66886 <br />CERTIFICATE OF AUTHORIZATION #7027 <br />FABRIC <br />CANOPY <br />STRUCTURAL <br />PLAN AND <br />DETAILS <br />T-0" DIA <br />CANOPY FOUNDATION DETAIL <br />FABRIC CANOPY FOUNDATION PLAN <br />1/4" = 1'-0" <br />SHEET: <br />si <br />