NOTE <br />ARRANGE ALL WORK THAT REQUIRES POWER INTERRUPTIONS <br />TO THE STORE TO BE ACCOMPLISHED AFTER NORMAL STORE <br />BUSINESS HOURS. NOTIFY THE STORE MANAGER AND THE <br />WALMART CONSTRUCTION MANAGER A MINIMUM OF 48 HOURS <br />IN ADVANCE OF ALL STORE POWER INTERRUPTIONS. STORE <br />MANAGER MUST ALLOW FOR POWERING DOWN OF COMPUTER <br />SYSTEMS, MOVING AFFECTED PRODUCT, MODIFICATION OF <br />WALMART AFTER-HOURS WORK SCHEDULES, COORDINATION <br />WITH OTHER TRADES, AND OTHER CRITICAL SCHEDULING <br />CONCERNS. PROVIDE TEMPORARY POWER AS REQUIRED. <br />INSTALLATION OF NEW EQUIPMENT SHALL BE COMPLETED AND <br />THE POWER SYSTEM TESTED AND RE -ENERGIZED PRIOR TO <br />START OF BUSINESS THE FOLLOWING MORNING NO LATER <br />THAN A TIME ESTABLISHED BY THE STORE MANAGER AND <br />THE WALMART CONSTRUCTION MANAGER. <br />ONE -LINE DIAGRAM LEGEND <br />NEW EQUIPMENT <br />EXISTING EQUIPMENT <br />EQUIPMENT TO BE DEMOLISHED <br />NOTE: <br />ALL OF THE ELECTRICAL DEVICES SHOWN ON THE RISER <br />DIAGRAM ARE EXISTING AND ARE BASED UPON AS -BUILT <br />DRAWINGS. E.C. SHALL VERIFY THE EXACT EXISTING <br />CONDITIONS, SIZES AND LOCATIONS OF EQUIPMENT PRIOR TO <br />ROUGH -IN. THIS RISER IS SHOWN FOR INFORMATIONAL <br />PURPOSES ONLY AND ANY NEW DEVICES ARE SHOWN IN <br />BOLD AND ARE NOTED. DURING CONSTRUCTION, THE STORE <br />SHALL STAY OPEN FOR BUSINESS. ANY NECESSARY POWER <br />DOWNTIME SHALL BE SCHEDULED AND APPROVED BY <br />WALMART CONSTRUCTION MANAGER. <br />PANELBOARD NOTES () <br />(1) TERMINATE GROUND ON ISOLATED GROUND BUS. <br />(2) INSTALL LOCKING DEVICE (LOCK -OFF FOR <br />MAINTENANCE). LOCKING DEVICE SHALL BE UL LISTED. <br />MANUFACTURER SHALL MATCH EXISTING PANELBOARD <br />MANUFACTURER <br />(3) INSTALL LOCKING DEVICE (LOCK -ON FOR CRITICAL <br />LOAD). <br />(4) GFI BREAKER FOR PERSONNEL PROTECTION (5mA). <br />(5) GFI BREAKER FOR EQUIPMENT PROTECTION (30mA) <br />(6) CONDUCTOR SIZE HAS BEEN INCREASED FOR VOLTAGE <br />DROP. SIZE EQUIPMENT GROUNDING CONDUCTOR <br />PROPORTIONATELY PER NEC. <br />(7) REFER TO ONE -LINE DIAGRAM FOR AVAILABLE FAULT <br />CURRENT FOR INTERRUPT RATINGS. <br />(8) REFER TO ONE -LINE DIAGRAM FOR WIRE SIZES. <br />(9) FACTORY WIRED TO LOAD. <br />(10) BREAKER SHALL BE HIGH MAGNETIC TYPE. <br />(11) NEW PNLBD TO REPLACE EXISTING PNLBD WITH THE <br />SAME NAME. NEW PNLBD POPULATION WAS <br />DETERMINED BY ORIGINAL CONSTRUCTION DRAWINGS. <br />E.C. SHALL VERIFY THAT ALL EXISTING BRANCH <br />CIRCUITS ARE EXTENDED TO NEW PNLBD LOCATION. <br />E.C. SHALL VERIFY CONDITION OF EXISTING BRANCH <br />CIRCUIT CONDUIT AND WIRE TO EXTEND PRIOR TO <br />USE, TO INSURE THAT THEY MEET ALL U.L. RATINGS <br />AND REPLACE AS REQUIRED. <br />(12) ROUTE CIRCUIT THROUGH "SWEATMISER PNLBD" <br />(13) EXISTING CIRCUIT TO REMAIN. <br />(14) ROUTE CIRCUIT THROUGH NEW CONTACTOR <br />(15) PROVIDE INTERLOCK WIRING WITH EXHAUST HOOD <br />ANSUL SYSTEM. <br />(16) RELOCATE CIRCUIT FROM EXISTING PANELBOARD. <br />(17) PROVIDE LUG ADAPTERS AS REQUIRED. <br />(18) HACR CIRCUIT BREAKER. <br />(19) EXISTING CIRCUIT BREAKER TO REMAIN. VERIFY <br />CONDITION OF CIRCUIT BREAKER TO ENSURE THAT IT <br />IS OPERATIONAL AND MEETS ALL U.L. RATINGS. <br />(20) ROUTE CIRCUIT THROUGH EXISTING LCU CABINET <br />UTILIZING EXISTING RELAY AND CONTROLS. UPDATE <br />LCU IDENTIFICATION SCHEDULE WITH LOAD <br />IDENTIFICATION. <br />(21) PROVIDE HANDLE LOCK OFF DEVICE TO LOCK "SPARE" <br />CIRCUIT BREAKER IN THE "OFF" POSITION. IF <br />CIRCUIT BREAKER IS IDENTIFIED AS "EXISTING", FIELD <br />VERIFY CIRCUIT BREAKER INDICATED IS NOT <br />CONNECTED TO ANY LOAD AND UPDATE PANELBOARD <br />CIRCUIT DIRECTORY IDENTIFYING CIRCUIT AS "SPARE". <br />(22) PROVIDE U.L. LISTED OVERCURRENT DEVICE TO <br />COORDINATE AND MAINTAIN MANUFACTURER'S SERIES <br />RATED SYSTEM. <br />(23) SOLENOID OPERATED CIRCUIT BREAKER. REFER TO <br />ENERGY MANAGEMENT PLANS FOR CIRCUIT BREAKER <br />CONTROL. <br />(24) TRACE EXISITING CIRCUIT, IDENTIFY LOAD AND <br />PROVIDE COMPLETE TYPEWRITTEN PANELBOARD <br />IDENTIFICATION SCHEDULE AND PLACE ON INTERIOR <br />OF PANELBOARD DOOR. IF CIRCUIT IS A "SPARE" <br />THEN REFER TO PANELBOARD NOTE (21). <br />(25) PROVIDE LISTED HANDLE -TIE BETWEEN CIRCUIT <br />BREAKERS SHARING COMMON NEUTRAL FOR <br />SIMULTANEOUS TRIP. <br />(26) PROVIDE BLANK CIRCUIT BREAKER FILLER PLATE FOR <br />EXPOSED SPACE IN PANELBOARD. <br />GENERAL NOTES: <br />1. E.C. SHALL ADD OR REARRANGE CIRCUIT BREAKERS <br />WITHIN PANELBOARDS AS REQUIRED TO MATCH NEW <br />CIRCUIT DESIGNATIONS SHOWN ON DRAWINGS. <br />2. NEW OVERCURRENT PROTECTIVE DEVICES PLACED IN <br />EXISTING PANELBOARDS OR DISTRIBUTION BOARDS SHALL <br />MATCH THE TYPE AND AIC RATING OF EXISTING <br />OVERCURRENT PROTECTION DEVICES IN SAID BOARD. <br />3. E.C. SHALL TRACE ALL ELECTRICAL CIRCUITS FOR ALL <br />EXISTING ELECTRICAL PANELBOARDS AFFECTED BY THE <br />REMODEL AND IDENTIFY LOADS ON EACH CIRCUIT. <br />PROVIDE A COMPLETE TYPEWRITTEN PANELBOARD <br />IDENTIFICATION SCHEDULE FOR ALL AFFECTED <br />PANELBOARDS. <br />4. ALL OVERCURRENT DEVICES ARE NEW UNLESS NOTED <br />OTHERWISE. <br />20A WIRE SIZING SCHEDULE <br />ALL WIRE SIZES SHOWN ON PANEL SCHEDULES ARE <br />INTENDED TO BE MINIMUM ACCEPTABLE WIRE SIZE. <br />THE FOLLOWING SCHEDULE IS TO BE USED TO SIZE <br />WIRE FOR 20 AMP CIRCUITS (120 AND 277 VOLT). <br />LENGTHS (IN FEET) ARE INTENDED TO BE MAXIMUM. <br />-120 VOLT <br />#12 <br />#10 <br />#8 <br />#6 <br />1-5 AMPS <br />200 FT. <br />325 FT. <br />�490 FT. <br />770 FT. <br />6-10 AMPS <br />100 FT. <br />160 FT. <br />245 FT. <br />385 FT. <br />11-15 AMPS <br />70 FT. _ <br />110 FT.- <br />I 165 FT. _ <br />255 FT. <br />277 VOLT <br />.,..._..#12 <br />#1.0 ..�.._w.. <br />#8....._...__. <br />__......#6.w__.._.... <br />1-5 AMPS <br />480 FT. <br />760 FT. <br />FT. <br />1865 FT. <br />6-10 AMPS <br />240 FT.- <br />380 FT. <br />_1170 <br />585 FT. <br />930 FT.- <br />11-15 AMPS <br />160 FT. <br />250 FT. <br />390 FT. <br />-620 FT. <br />LLQ NEW <br />SERVES: LIQUOR SALES <br />LOCATION: LIQUOR STOCKROOM <br />MOUNTING: SURFACE <br />DESCRIPTION <br />1 FRONT CASH REGISTER <br />3 ICE MERCHANDISER <br />5 EXHAUST FAN <br />7 EWC (4) <br />9 HAND DRYER (2,6) <br />11 HAND DRYER (2,6) <br />1-11 <br />0 R OP R�T,W a <br />15 SHOW WINDOW RCPT (6 <br />17 EAS SYST M 3 <br />19 COOLER DOOR LTG (14) <br />2E1- <br />2TROOM LIGHTING <br />25 CAR CHARGER (2) <br />2 <br />2 CAR CHARGER (2) <br />31 <br />3 °� CAR CHARGER (2) <br />35 <br />37 <br />39 SPACE <br />41 SPACE <br />PER NEC ARTICLE 220 <br />33,915 <br />ELECTRICAL <br />ROOM #1 <br />ELECTRICAL <br />ROOM #3 <br />WIRE <br />BRKR <br />PL <br />KVA A <br />30 <br />30 <br />30 <br />1 <br />1 <br />1 <br />0.50 <br />3.64 <br />10 <br />10 <br />20 <br />20 <br />20 <br />1 <br />1 <br />1 <br />0.48 <br />0.20 <br />10 <br />20 <br />1 <br />20 <br />20 <br />1 <br />1a <br />0.24 <br />1.80 <br />8 <br />8 <br />40 <br />40 <br />2 <br />2 <br />3.12 <br />1.20 <br />3.12 <br />o • VA <br />KVA B <br />1.55 1 3.64 <br />1.15 1 0.86 <br />11 lill we] w <br />3.12 <br />,3 <br />CONTACTOR SCHEDULE <br />LABEL A S S H 0 WN...,,,.,......... <br />.,,.w.,,...°...._,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,.... <br />....,,,,,.........,,, ........ <br />.... <br />. .............. <br />.-._..._...�........,�..,.,_.,.....�......_...,,,.,._A. .,.._...,,._.,_...,.,,,.,.._....,,..,.n.__.. .,,,,,. ®.m.............°...mm._ ..,,,...°,.,,., <br />ENCLOSURE COIL CONTACTS NOTES <br />208Y/120V, 3PH, 4W <br />150A MCB N0. LOAD SERVED _ VOLTS <br />C1 LIQUOR NEMA-1 120V 600V1 <br />MECHANICALLY <br />SALES LIGHTING 20A-4P HELD <br />EQUIPMENT GROUND BUS <br />NOTE: REFER TO SHEET EM1 FOR EMS CONTROL INFORMATION. <br />ISOLATED GROUND BUS <br />KVA C <br />PL <br />BRKR <br />WIRE <br />DESCRIPTION <br />3 <br />50 <br />8 <br />CU-1 <br />30.3A, 208/3 <br />2 <br />4 <br />6 <br />0.53 <br />3.64 <br />1 <br />1 <br />1 <br />20 <br />20 <br />20 <br />COOLER DOOR POWER <br />CLR FANS(CU-1 a&CU-1 b)(2) <br />JANITOR RECEPTACLE <br />8 <br />10 <br />12 <br />1.15 <br />0.18 <br />1 <br />1 <br />1 <br />20 <br />20 <br />1 20 <br />STCKRM & RTU RCPT/BUZZ. <br />CU-2 CASE FANS (2) <br />CU-2 CASE LIGHTS (2,14) <br />14 <br />16 <br />18 <br />_0 54 <br />0.34 <br />w- - <br />3 <br />25 <br />_ _ <br />10 <br />_ <br />CU-2 <br />15.9A,_.208 -3 -- _ _ _ <br />20 <br />22 <br />24 <br />Q_15_ <br />1..80._ <br />3.12 <br />1 <br />1 <br />TOTAL 15.68 17.38 15.43 <br />131 145 129 <br />TOTAL LOAD 48.49 KVA 135 <br />FEEDER LOAD 43.74 KVA 121 <br />EXISTING <br />UTILITY TRANSFORMER <br />480Y/277V, 30, 4W SEC <br />EXISTING DISTRIBUTION SYSTEM IS <br />SERIES RATED. E.C. SHALL PROVIDE <br />CIRCUIT BREAKER(S) THAT WILL <br />MAINTAIN EXISTING MANUFACTURER'S <br />U.L. LISTED SERIES RATED SYSTEM. <br />MSB1 EXISTING <br />4000 AMPS 480Y/277V 30 4W <br />CT 800A C 600A <br />ETR \� ETR <br />1 <br />1 <br />20 <br />20 <br />NEON COOLER SIGN <br />ROLL UP DOOR <br />2 <br />30 <br />0.86 <br />1 <br />1 <br />A E <br />SPACE <br />SPACE <br />34 <br />36 <br />1 <br />1 <br />1 <br />SPACE <br />SPACE <br />SPACE <br />38 <br />40 <br />42 <br />KVA <br />AMPS <br />AMPS <br />AMPS <br />DRY TYPE TRANSFORMER <br />SCHEDULE <br />A R Y .,... ....a__ <br />._......®..�SE..�-._._ <br />CONDARY <br />MOUNTING LOCATION <br />VOLTS PHASE WIRES <br />_ <br />VOLTS PHASE WIRES <br />MOUNT AT BAR JOIST <br />TLLQ <br />45 <br />480V 3PH 3W <br />120/208V 3PH 4W <br />NOTES A,B,C,D <br />WITH TAPS <br />DRY TYPE °TRANSFORMER NOTES: <br />A. GROUND IN ACCORDANCE WITH NEC 250-30. <br />B. TRANSFORMERS SHALL BE 150 DEC C RISE, MAXIMUM, WITH ANSI/NEMA <br />MAXIMUM SOUND LEVELS. <br />C. CLEARANCE FOR VENTILATING OPENINGS SHALL BE NO LESS THAN THAT <br />REQUIRED ON MANUFACTURERE'S NAMEPLATE. NEC 110-13(B), <br />450-9 AND 450-11. <br />D. EQUIPMENT SHALL BE MANUFACTURED BY CUTLER -HAMMER, SIEMENS <br />OR SQUARE D. <br />COORDINATE ALL CHANGES TO EXISTING ELECTRICAL SERVICE <br />AND METERING WITH UTILITY COMPANY. <br />STORE ADDRESS: WALMART LBA <br />7631 GALL BLVD. <br />ZEPHYRHILLS, FL 33541 <br />UTILITY COMPANY: TAMPA ELECTRIC COMPANY <br />PHONE: 813 635-1500 <br />IF IT IS NECESSARY TO REMOVE A METER, RTU <br />SERVER, CT OR DISRUPT THE COMMUNICATION OF THE <br />SYSTEM, THE CONTRACTOR IS RESPONSIBLE TO <br />RESTORE THE SYSTEM TO THE SAME LEVEL OF <br />OPERATION THAT EXISTED PRIOR TO THE WORK BEING <br />INITIATED. THE EXISTENCE AND FUNCTIONALITY OF THE <br />SYSTEM SHALL BE VERIFIED BY CALLING WALMART <br />BUILDING PERFORMANCE TEAM AT 479-204-0452 <br />BETWEEN THE HOURS OF 7 AM UNTIL 5 PM CT. <br />EXISTING <br />EXISTING <br />EXISTING <br />PNLBD <br />PNLBD <br />PNLBD <br />H1B2 <br />H4B <br />H4C <br />30Y/277V <br />80Y/277V <br />80Y/277 <br />EXISTING <br />PNLBD <br />H3B <br />80Y/277 <br />NEW <br />PNLBD <br />L.3B <br />8Y/120 <br />16.477 <br />(70A-3P) <br />3Dtj 4 <br />50KVA <br />•80V E2 <br />UXSTING11 ) <br />EXISTING <br />PNLBD <br />L3D1 <br />208Y/120V <br />UPS <br />SYSTEM <br />NEW <br />PNLBD <br />L1 U <br />08Y/120V <br />J ... leLeaaI«.L >,oM .. <br />GR SIDE PARTIAL ONE -LINE <br />NTS <br />CABLE WHIPS OUT OF POWER POLE SHALL BE INSTALLED IN <br />A NEAT AND WORKMAN -LIKE MANNER. ROUTE CABLE WHIPS <br />TO TERMINATIONS ALONG UNISTRUT OR STRUCTURE AND <br />SUPPORT EVERY 12" TO 24". EXCESS CABLE SHALL BE <br />TIGHTLY COILED AND ATTACHED TO UNISTRUT OR JOIST. <br />12" PVC SLEEVE <br />2-1/2" UNISTRUT <br />STRAP FIRMLY CLAMPED <br />TO CONDUIT -� <br />POWER POLE <br />2-1/2' INSET j <br />PVC <br />CONDUIT <br />INSET: CLAMP A 12" LENGTH <br />OF PVC CONDUIT AND RUN THE <br />POWER POLE THROUGH ITS CENTER <br />NO CONNECTION OF ANY KIND SHALL BE MADE <br />TO JOIST WEB MEMBERS, JOIST BRIDGING, OR <br />ROOF DECK. MAINTAIN MINIMUM 6" CLEARANCE <br />FROM TOP OF POWER POLE TO ROOF DECK. <br />REF MANUFACTURER'S "GENERAL <br />FITTINGS SPECIFICATIONS" FOR <br />DESIGN BOLT TORQUE. <br />EXTEND POWER POLE 3" <br />MIN ABOVE CL OF UNISTRUT <br />INSTALL CEILING FLANGE <br />PROVIDED WITH POLE FOR <br />STORES WITH LAY -IN CEILING <br />CONTRACTOR SHALL ATTACH POWER <br />POLE TO CHECKOUT STAND PER <br />MANUFACTURER RECOMMENDATIONS <br />UNISTRUT---- <br />Voltage Drop Calculations: FBC-EC 2010 <br />Voltage Drop Calculations: <br />VOLTAGE DROP CALCULATIONS HAVE BEEN <br />PERFORMED, THIS DESIGN COMPLIES WITH <br />VOLTAGE DROP REQUIREMENTS OF FBC <br />ENERGY CONSERVATION 505.7.3. OF FEEDER <br />(< 2%) AND BRANCH (<3%) CIRCUITS. <br />Y/120V <br />H4B IS 104' <br />AWAY IN EDC4 <br />AND HAS A <br />VOLTAGE DROP <br />OF 0.63 <br />LLQ IS 9' <br />AWAY IN AND <br />AND HAS A <br />VOLTAGE DROP <br />OF 0.11 <br />NEW C1 1 .29 <br />PNLBD REF: 2-EM1 <br />"'°' INSTALL IN 5"X8"X4" NEMA-1 <br />LLQ ENCLOSURE WITH NAMEPLATE <br />08Y/120V INDICATING "CONTACTOR <br />CONTROL XFMR". <br />LIQUOR STOCKROOM <br />DIAGRAM <br />PROVIDE UNISTRUT PER <br />SPECIFICATIONS. LENGTH AS <br />REQUIRED TO SPAN JOISTS. <br />SECURE TO BOTTOM CHORD <br />OF BAR JOIST. <br />PROVIDE 1 /4" BOLT <br />AND 1-1/4" FENDER <br />WASHER TYP <br />PROVIDE UNISTRUT <br />P1026 ANGLE <br />FITTING OR EQUAL <br />' PROVIDE 1-1/4" '�BOTTOM <br />FENDER WASHER, LOCK INSET CHORD OF <br />WASHER AND NUT, TYP BAR JOIST <br />INSET: MOUNT UNISTRUT ABOVE BOTTOM CHORD OF BAR <br />FINISHED JOISTS USING 1 /4" BOLTS, WITH FENDER WASHERS AND <br />FLOOR LOCK WASHERS BETWEEN BOLT HEAD AND JOIST FLANGE <br />L <br />1 /8" = 1'-0" <br />H1A H1B1 H1B2 <br />ELECTRICAL MSWB <br />ROOM #1 L1 D2-19,21 <br />H1P2 16.470� <br />TD2 L1 D H1 P1 16.501 <br />jI <br />EXISTING FIRE <br />ALARM BOARD <br />ALARM POWER <br />A WARNING <br />ARC FLASH AND SHOCK HAZARD. <br />APPROPRIATE PERSONAL PROTECTIVE <br />EQUIPMENT (PPE) REQUIRED. <br />NOTES: <br />A. ALL SWITCHBOARDS AND PANELBOARDS SHALL <br />HAVE A COMMERCIALLY PRODUCED PERMANENT LABEL <br />APPLIED, SIMILAR TO THE ABOVETO WARN OF <br />POTENTIAL ARC FLASH HAZARDS,, IN ACCORDANCE <br />WITH NEC 110.16 AND NFPA 70E. <br />B. LABELING MAY BE COMPLETED BY EQUIPMENT <br />MANUFACTURER, EQUIPMENT VENDOR/SUPPLIER, OR <br />THE CONTRACTOR. THE CONTRACTOR SHALL VERIFY <br />THAT ALL SWITCHBOARDS AND PANELBOARDS ARE <br />PROPERLY LABELED IN THE FIELD. <br />ARC FLASFI_QE -1 1 <br />L <br />5 NTS 02.17.06 WREP44 <br />PROVIDE SEISMIC <br />BRACING AS REQUIRED <br />BY STATE OR LOCAL <br />ORDINANCES. <br />SUSPEND STEEL ANGLES <br />FROM BAR JOIST WITH <br />1/2" THREADED STEEL; <br />ROD AS REQUIRED TO <br />MAINTAIN CLEAR SPACE j <br />IN FRONT OF I <br />TRANSFORMER PER NEC! <br />REQUIREMENTS, TYP. <br />1/2" THREADED STEEL ROI <br />DRILL 5/8" HOLES THROUC <br />ANGLES AND INSTALL LOCH <br />WASHERS AND NUTS ON E <br />SIDE, TYP. <br />6'-0" MAXIMUM SPACING <br />:1 SU�SPENDED �TR <br />Y / iris <br />..••� - <br />III <br />I'paw, <br />I pm <br />COORDINATE EXACT LOCATION <br />WITH STORE SETUP SUPERVISOR <br />PRIOR TO INSTALLATION. <br />n LIOUOR <br />POWER PLAN <br />UC11431Nl7 UINI I, <br />OF 2. <br />CIRCUIT SCHEDULE GENERAL POWE <br />R NOTES <br />73 70A, (3)#4, (1)#8G, 1" C 1. TELEPOWER POLE(S): MOUNT JUNCTION BOX(ES) TO TOP <br />155 150A, (4)#1 /0, (1)#6G, (1)#6 IG, 2" C SIDE OF BOTTOM CHORD OF BAR JOIST. INSTALL <br />FURNISHED PRE -WIRED POWER POLE AND TERMINATE <br />G150 GND, #6 COPPER GROUND, 3/4" C PROVIDED FLEXIBLE CONDUIT AND WIRING TO JUNCTION <br />BOX. PROVIDE UNISTRUT SUPPORTS AND HARDWARE TO <br />ALL CONDUCTOR SIZES ARE BASED ON 75 DEG C SECURE TELEPOWER POLE PLUMB TO BUILDING <br />RATED TERMINATIONS AND TYPE THHN/THWN-2 STRUCTURE. <br />INSULATION; FOR TERMINATIONS OR INSULATION TYPES 2. PROVIDE LIQUID -TIGHT FLEXIBLE METAL CONDUIT AND <br />RATED LESS THAN 75 DEG C, MODIFY SIZES WIRING FROM DISCONNECT SWITCH OR JUNCTION BOX TO <br />ACCORDING TO NFPA 70. EQUIPMENT KNOCKOUT OR ELECTRICAL CONNECTION <br />POINT. <br />LOW VOLTAGE WIRING 3. WHERE EQUIPMENT NAMEPLATE PROTECTIVE DEVICE <br />RATING DIFFERS FROM SIZE PROVIDED, CHANGE OUT <br />BRANCH CIRCUIT WIRING AND OVERCURRENT DEVICE TO <br />APPROPRIATE RATING PER NEC. <br />ALL LOW VOLTAGE WIRING AND CABLE IS REQUIRED TO BE 4. ELECTRONIC FIRE PROTECTION/SECURITY ALARM BOXES <br />PLENUM RATED. COORDINATE PROPER CABLE TYPES AND CONDUITS SHOWN ON POWER PLANS SHALL BE <br />REQUIRED WITH WAL-MART ALARM DIVISION AND WAL-MART PROVIDED UNDER THIS CONTRACT. IN ADDITION, UNLESS <br />CONSTRUCTION MANAGER PRIOR TO INSTALLATION. NOTED OTHERWISE, THE FOLLOWING GENERAL NOTES <br />APPLY: <br />A. ALL ALARM JUNCTION BOXES SHALL BE <br />4"X4"X2-1/8" MINIMUM. <br />B. ALARM RACEWAYS SHALL BE 3/4" MINIMUM WITH <br />PULL WIRE AND INSULATING BUSHINGS AT END OF <br />VERTICAL RACEWAY RUN. <br />C. VERTICAL RACEWAYS FROM ALARM BOXES SHALL BE <br />EITHER CONCEALED INSIDE WALL OR SURFACE <br />MOUNTED (TO MATCH JUNCTION BOX MOUNTING). ALL <br />VERTICAL RUNS SHALL BE TURNED 90-DEGREES AT <br />TOP SIDE OF BOTTOM CHORD OF BAR JOIST AND <br />EXTENDED HORIZONTALLY TO A LOCATION ACCESSIBLE <br />BY VERTICAL FLOOR TYPE LIFT. <br />5. UPON COMPLETION OF ELECTRICAL INSTALLATION AND <br />PRIOR TO ENERGIZING CIRCUIT: <br />,.r..... ,, r�.�$°��A °°, E�°„�°_. � ��,,- A. INSPECT WIRE AND CABLE FOR PHYSICAL DAMAGE. <br />B. PERFORM CONTINUITY TEST. <br />C. VERIFY PROPER PHASING CONNECTION TO ALL THREE <br />3"x2"x1/4" STEEL ANGLES PHASE MOTOR LOADS. <br />BETWEEN BAR JOIST ON EACH SIDE <br />TRANSFORMER. MOUNT (WHERE WI ELECTRICAL KEYNOTES <br />WITHIN 4" OF PANEL POINT WHEERE <br />WEB BRACING ATTACHES TO BOTTOM <br />CHORD). BOLT OR CLAMP ANGLES <br />TO BAR JOIST. DO NOT CUT OR 16.226 ELECTRICAL ARTICLE SURVEILLANCE SYSTEM: <br />DRILL HOLES IN BAR JOIST. PROVIDE 3/4" CONDUITS (WITH PULL WIRE) <br />FROM EAS POWER MODULE TO EAS <br />PEDESTAL LOCATION AS SHOWN ON PLANS, <br />BAR JOIST WITH OVERALL LENGTH OF EACH CONDUIT <br />NOT TO EXCEED 36'. STUB CONDUITS 3" <br />j ABOVE FINISHED FLOOR AT EAS PEDESTAL <br />LOCATION AND EXTEND CONDUIT UP WALL <br />TO HEIGHT OF THE EAS RECEPTACLE, <br />TRANSFORMER PROVIDE BUSHINGS AT EACH END. <br />16.227 ELECTRIC WATER COOLER RECEPTACLE: <br />CEILING MOUNTING BRACKETS AS CONCEAL WITHIN CABINET PER MANUFACTURERS <br />FURNISHED BY TRANSFORMER REQUIREMENTS. <br />MANUFACTURER OR USE 2"x2"xl/4" <br />ANGLES. BOLT TRANSFORMER TO 16.232 AUTOMATIC DOOR OPERATOR: VERIFY LOCATION <br />BRACKETS OR ANGLES. WITH MANUFACTURER'S RECOMMENDATIONS PRIOR <br />TO INSTALLATION. ALL CONDUIT AND WIRING <br />SHALL BE CONCEALED AT MAIN ENTRANCE DOORS. <br />FORMERMOUNTING 16.233 ROOF TOP UNIT IS PROVIDED WITH A HACR <br />EP21 a RATED CIRCUIT BREAKER AND GFI DUPLEX <br />RECEPTACLE. <br />16.238 CONTRACTOR SHALL PROVIDE A 1/2" FLEXIBLE <br />CONDUIT WITH PULL STRING ROUTED FROM CEILING <br />SPACE BELOW UP THROUGH THE NEW CURB <br />ADAPTER, PENETRATING THE BOTTOM OF THE RTU'S <br />ELECTRICAL COMPARTMENT. THIS RACEWAY IS <br />REQUIRED FOR FUTURE FIRE ALARM COMMUNICATION <br />CABLING BY OTHERS. <br />16.243 INSTALL MANUFACTURER FURNISHED JUNCTION <br />BOX ABOVE DOOR HEADER FOR CAMERA CABLING. <br />PROVIDE 1" CONDUIT (WITH PULL WIRE) FROM <br />JUNCTION BOX TO STRUCTURE. TERMINATE AT <br />BAR JOIST WITH BUSHINGS. COORDINATE <br />INSTALLATION WITH MANUFACTURER'S <br />IDE REQUIREMENTS. <br />a <br />TI 16 299 INSTALL EMS 120V/24VAC TRANSFORMER. <br />WIT CONNECT TO 120V RECEPTACLE CIRCUIT WITH <br />(2)#12, (1)#12G. COORDINATE INSTALLATION <br />AND PROCUREMENT WITH EMS CONTRACTOR. <br />REFER TO EMS PLAN INDICATED. <br />0 <br />--- 16.470 FURNISH AND INSTALL NEW 20 AMP, 120 VOLT <br />CIRCUIT(S). FEED FROM PANELBOARD AS <br />INDICATED. PROVIDE 20A-1P CIRCUIT BREAKER <br />IF NEEDED. E.C. SHALL MATCH MANUFACTURER, <br />° TYPE AND AIC RATINGS OF EXISTING CIRCUIT <br />BREAKERS. E.C. SHALL VERIFY PRIOR TO <br />ROUGH -IN THAT EXISTING PANELBOARD HAS <br />° SPARE CAPACITY TO ACCOMMODATE ADDITIONAL <br />LOAD. <br />16.471 FURNISH AND INSTALL NEW 20 AMP, 120 VOLT <br />ISOLATED GROUND CIRCUIT(S). FEED FROM PANEL <br />BOARD AS INDICATED. PROVIDE 20A-1P CIRCUIT <br />BREAKER IF NEEDED. E.C. SHALL MATCH <br />MANUFACTURER, TYPE AND AIC RATINGS OF <br />EXISTING CIRCUIT BREAKERS. PROVIDE ORANGE <br />ROUGH -IN THAT EXISTING PANELBOARD HAS SPARE <br />COVER PLATES ON ALL ISOLATED GROUND DEVICES <br />WITH CIRCUIT NUMBER ENGRAVED UNLESS NOTED <br />OTHERWISE. E.C. SHALL VERIFY PRIOR TO <br />CAPACITY TO ACCOMMODATE ADDITIONAL LOAD. <br />16.472 FURNISH AND INSTALL NEW CIRCUIT <br />BREAKER (##A-#P) IN EXISTING PANELBOARD <br />INDICATED. E.C. SHALL MATCH MANUFACTURER, <br />TYPE AND AIC RATINGS OF EXISTING CIRCUIT <br />BREAKERS. E.C. SHALL VERIFY PRIOR TO <br />ROUGH -IN THAT EXISTING PANELBOARD HAS <br />SPARE CAPACITY TO ACCOMMODATE <br />ADDITIONAL LOAD. <br />FURNISH AND INSTALL NEW CIRCUIT <br />16 --�---- .477 <br />BREAKER (##A-#P) IN EXISTING PANELBOARD <br />INDICATED. PROVIDE CIRCUIT BREAKER LOCKING <br />DEVICE (LOCK -OFF FOR MAINTENANCE). <br />BE E.C. SHALL MATCH MANUFACTURER, <br />\TION TYPE AND AIC RATINGS OF EXISTING CIRCUIT <br />OR BREAKERS. E.C. SHALL VERIFY PRIOR TO <br />ITS ROUGH -IN THAT EXISTING PANELBOARD HAS <br />'ED SPARE CAPACITY TO ACCOMMODATE <br />ADDITIONAL LOAD. <br />-° - 16.501 A PROVIDE TWO (2) 20A, 120 VOLT DEDICATED <br />CIRCUITS AND FINAL CONNECTIONS TO FIRE ALARM <br />BACKBOARD EQUIPMENT PROVIDED BY OTHERS. <br />COORDINATE INSTALLATION WITH ALARM INSTALLER <br />PRIOR TO ROUGH -IN. <br />16.600 PROVIDE SURFACE MOUNTED ALARM JUNCTION <br />BOX (WITH VERTICAL RACEWAY) MOUNTED 2" <br />ABOVE AND 8" IN FROM STRIKE SIDE OF <br />DOOR FRAME. <br />16.601 PROVIDE SURFACE MOUNTED ALARM JUNCTION BOX <br />(WITH VERTICAL RACEWAY) ADJACENT TO AND <br />EVEN WITH TOP OF DOOR FRAME. <br />16.610 PROVIDE SURFACE MOUNTED ALARM JUNCTION <br />BOX (WITH VERTICAL RACEWAY) AT +84" <br />(UNLESS NOTED OTHERWISE). <br />16.619 PROVIDE 4"X4"X2-1 /8" RECESSED ALARM <br />JUNCTION BOX IN CEILING WITH <br />4"X4"X"1-1/2" EXTENSION RING WITH <br />-- - RACEWAY ROUTED TO NEAREST ACCESSIBLE <br />CEILING SPACE. <br />16.650 CONDUIT SLEEVE: PROVIDE 1-1/2" CONDUIT <br />SLEEVE WITH BUSHINGS ABOVE BAR JOIST <br />(UNLESS NOTED OTHERWISE). PROVIDE <br />TEMPORARY FIRE STOP WITHIN CONDUIT. <br />DRISTNG CONDIONS WEE TAKEN FROAWIINGS AANDITMAY NOTRREFLECT-EXACTORIGINAL - AATHOROECH UGOHNKNOWLEDGE OFSALOLNDI°RAWINGS ANDING <br />- ° -- "AS -BUILT" CONDITIONS. CONTRACTOR SHALL FIELD SPECIFICATIONS IN THEIR RELATED FIELD. THE <br />VERIFY ALL EXISTING CONDITIONS PRIOR TO FAILURE TO ACQUAINT THEMSELF WITH THIS <br />SUBMITTING FINAL BIDS. CONTRACTOR SHALL KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY <br />CAREFULLY COORDINATE NEW WORK AND DEMOLITION OF PERFORMING THE WORK PROPERLY. NO <br />WITH ALL OTHER DISCIPLINES AND EXISTING ADDITIONAL COMPENSATION SHALL BE ALLOWED <br />CONDITIONS. BECAUSE OF CONDITIONS THAT OCCUR DUE <br />TO FAILURE TO FAMILIARIZE WORKERS WITH THIS <br />KNOWLEDGE. <br />N <br />O <br />0 0 <br />0 <br />U <br />1~ � <br />a) <br />I <br />e <br />16 a <br />o <br />24, <br />W <br />R° <br />U <br />a <br />Uj W rw woZ� <br />Nz� Zwvai�WZ3 <br />W o r-Ep zjoopo-j <br />O Uajz a �w�Fpo <br />aN �Qorz�Fa�w�o <br />z Q L�. <br />O 3v�04=> �Za�ra <br />w zO <br />J Oo <br />ZJO� <br />�vJQ �ON_ <br />O <br />�<�oN <br />Z=L6U-W�w�OJc� 09- <br />LI <br />H SQwdZr9owli3OU' Qor <br />V) Mv) 0ov=iav)wmxzoa< <br />z <br />0 <br />O 0 <br />E_ <br />a <br />� <br />aoa <br />O O <br />x <br />0 <br />rrLij <br />cr <br />M.� <br />CD <br />f--a <br />0 <br />�+ <br />z <br />W <br />� <br />0 <br />o <br />O <br />0 <br />CQ <br />w <br />N <br />44 <br />� <br />z <br />0 <br />ISSUE BLOCK <br />0 <br />PR#1 <br />08/22/14 <br />0 <br />REISSUE <br />12/04/15 <br />ADD#3 <br />07/11 /16 <br />CHECKED BY: <br />JPM <br />DRAWN BY: <br />PW <br />PROTO: <br />LBA <br />PROTO CYCLE: <br />051514 <br />DOCUMENT DATE: <br />120415 <br />,�N. FtADEEp����,i <br />".4 C-ip�. �� G EN <br />N o 7 1 7 ' 9N <br />O: ST E OF :4 <br />ORI <br />Jul 11, 2016 <br />POWER <br />PLAN <br />DETAILS <br />AND <br />SCHEDULES <br />SHEET: <br />E2 <br />