A <br />REFRIGERATION BAS SYMBOLS <br />CX-03.01.19 <br />ES1 NOVAR EDGE SERVER GATEWAY <br />E2E EMERSON RX300 GATEWAY <br />RC2-XE NOVAR SPECTRUM RACK CONTROLLER <br />XCM.20R NOVAR OPUS RACK CONTROLLER <br />BAS BUILDING AUTOMATION SYSTEM <br />TEMP TEMPERATURE <br />VFD VARIABLE FREQUENCY DRIVE <br />XFMR TRANSFORMER <br />COMM COMMUNICATION PORT/MODULE <br />CIM CASE INPUT MODULE <br />LTA-X REFRIGERATION CIRCUIT <br />SO REMOTE TEMPERATURE SENSOR <br />2 3 OD DEFROST TERMINATION SENSOR <br />DTS DUAL TEMP SWITCH <br />RIB RELAY IN BOX <br />RCC NOVAR CIRCUIT CONTROLLER <br />CMS CASE MANAGEMENT SYSTEM MODULE <br />AOM ANALOG OUTPUT MODULE <br />EXISTING 81M UNIVERSAL INPUT MODULE <br />DAIRY RIM RACK INPUT MODULE <br />COOLER <br />S3C SPORLAN WALK-IN CONTROLLER <br />r-------i <br />S3C ; SPORLAN CASE CONTROLLER <br />L______J <br />ssc; ssc; ssc; Issc; SGR SPORLAN GATEWAY ROUTER <br />�(j > ti° C18.1a C18.1b D7.3a D7.3b SNS SPORLAN NETWORK SWITCH <br />C18.3c C18.3b o EMS BACKBOARD <br />N S3C S3C M <br />`T; �_ � ;�; ;�; DS DOOR SWITCH <br />U �j ` S3C S3Cj U <br />�O XIO BACNET INPUT/OUTPUT MODULE <br />.�; N C18.3e C18.3f <br />2nco <br />' KE2 WALK-IN FREEZER REFRIG CIRCUIT CONTROLLER <br />U D7.1 c D7.1 b D7.1 a D7.2c D7.2b D7.2a <br />ssc, ssc; ssc; 11SK, 1s5c1 ssc NEW FIELD INSTALLED EQUIPMENT <br />C15.3a EXISTING EQUIPMENT <br />S3C <br />NEW FACTORY INSTALLED EQUIPMENT <br />' N <br />,T,M EQUIPMENT TO BE DEMOLISHED <br />U � <br />` U <br />�S3C� <br />C15.3d <br />EXISTING <br />GROCERY <br />FREEZER ;C; B12a <br />N MiMi <br />EXISTING RACK D <br />CONTROLLER -- -_� <br />N icU.i irUji N <br />EXISTING <br />ICE CREAM <br />FREEZER <br />o <br />EXISTING RACK C <br />CONTROLLER <br />2 3 <br />EXISTING ;U; §sc; BASR2 BASR2 <br />COMPRESSOR EXISTING <br />HOUSE #2 ------ MEAT (TYP) <br />COOLER m Lam' m <br />EXISTING CIM <br />BACKBOARD <br />MOUNTED <br />ABOVE MEAT <br />PREP - <br />EXISTING RACK B c2; ;ssc1 <br />CONTROLLER <br />EXISTING 67d <br />MEAT <br />PREP <br />EXISTING <br />COMPRESSOR <br />HOUSE #1 --�� <br />EXISTING RACK A <br />CONTROLLER <br />EXISTING ES1(S)AND <br />DTS MOUNTED ON <br />BACKBOARD INSIDE <br />EDC4. REF 1/BASR2. /1 <br />EDC4 <br />;M; <br />o <br />A9c <br />A9b <br />U <br />EXISTING <br />PICKUP <br />� <br />ssc; <br />�S3C <br />�S3C <br />COO! F <br />A10a <br />A10b <br />EXISTING <br />A5b <br />PICKUP <br />ccA5c <br />FREEZER <br />7,3; <br />;ssc; <br />ssc; <br />EXIJTIn <br />Imo; <br />U <br />Q <br />°o <br />PICKU <br />- - COOLS <br />m <br />;v <br />m <br />A6a <br />A6b <br />61c <br />Cl1b <br />�83C� <br />�S3C� <br />MOUNT NEW P <br />SGR(S) ON <br />BACKBOARD '61 <br />INSIDE EDC4 <br />EXISTING <br />PRODUCE <br />COOLER <br />EXISTING <br />BAKERY <br />FREEZER <br />EXISTING <br />BAKERY <br />COOLER <br />C6b C6a <br />�S3C� �S3C� <br />W <br />Aga <br />Al2d <br />Al2c <br />Al2b <br />�S3C� <br />�S3C� <br />�S3C� <br />�S3C� <br />�rUi� <br />N <br />�S3C� <br />�S3C� <br />�S3C� <br />IS3Cl <br />A10c <br />A11a <br />A11b <br />A11c <br />Asa <br />A8d <br />ASc <br />A8b <br />�S3C� <br />�S3C� <br />�S3C� <br />�S3C' <br />�83C� <br />�S3C� <br />�S3C� <br />�S3C� <br />A6c <br />Ala <br />Alb <br />A7c <br />B1a <br />B2d <br />B2c <br />B2b <br />�S3C� <br />�S3C� <br />�S3C� <br />�S3C� f 1 <br />C2b <br />U ,T. S3C U' U <br />C2d <br />Cob CC4a <br />`S3C� �S3C� <br />EXISTft <br />DELI <br />COOLER <br />EXISTING <br />DELI <br />FREEZER_ - <br />gym; m <br />GENERAL REFRIGERATION <br />BAS NOTES <br />CX-08.16.12 <br />1. COORDINATE THE EXTENT OF BAS DEMOLITION WITH FIXTURE <br />PLANS. REMOVE ENTIRE LENGTH OF CONDUIT AND BAS CABLES. <br />DO NOT ALLOW DEMOLITION TO AFFECT ACTIVE BAS CIRCUITS. <br />LABEL TERMINATION POINTS OF DEMOLISHED CABLES IN BAS <br />EQUIPMENT AS 'SPARE'. <br />2. CONTACT THE CURRENT BAS VENDOR TO OBTAIN A CURRENT <br />MODULE CONFIGURATION PRINTOUT PRIOR TO INSTALLING BAS <br />CABLES. TERMINATE BAS CABLES ACCORDING TO THE BAS <br />CONFIGURATION SHEETS. <br />3. THE BAS SUPPLIER RESERVES THE RIGHT TO CHANGE AND/OR <br />MODIFY ANY/ALL COMPONENTS AND TO MAKE CHANGES TO <br />EQUIPMENT DESIGN. <br />4. CABLE IS FURNISHED BY THE CONTRACTOR UNLESS NOTED <br />OTHERWISE, INSTALL CABLE ACCORDING TO DRAWINGS. NO <br />DEVIATION FROM DRAWINGS WILL ACCEPTED. LABEL EACH END <br />OF BAS CABLES WITH TERMINATION POINT OF THE OPPOSITE <br />END OF THE BAS CABLE. <br />5. TERMINATE BAS CABLES IN ACCORDANCE WITH OWNER AND <br />BAS SUPPLIER INSTALLATION INSTRUCTIONS. DO NOT EXPOSE <br />MORE THAN 3" OF WIRE(S). COVER THE END OF THE INSULATING <br />JACKET OF ALL BAS CABLES WITH HEAT SHRINK TUBING. DO <br />NOT ALLOW EXPOSURE OF FOIL OR UNUSED WIRE(S) AFTER <br />APPLICATION OF HEAT SHRINK TUBING. <br />6. MINOR CHANGES IN MATERIALS OR TERMINATIONS WILL, IN NO <br />CASE, CAUSE AN INCREASE IN COST TO OWNER OR SERVE <br />CAUSE TO GENERATE CHANGE ORDER PAPERWORK. OWNER <br />OR BAS SUPPLIER WILL NOT ACCEPT CHANGE ORDER <br />PAPERWORK PERTAINING TO BAS INSTALLATION OR <br />TERMINATION AS DESIGNATED ON DRAWINGS. <br />7. ROUTE BAS CABLES IN CONDUIT WHEN BELOW BAR JOIST LEVEL <br />OR IF EXPOSED TO VIEW FROM THE SALES AREA. BAS CABLES <br />MAY BE STRUNG ALONG OR PERPENDICULAR BAR JOISTS IF <br />SUPPORTED AT LEAST EVERY 36" OR MINIMUM DISTANCE OF <br />BAR JOIST SPACING. <br />8. CONCEAL SALES AREA BAS CONDUIT UNDER REFRIGERATED <br />CASES, THROUGH TUNNELS, WALLS, PIPE RACKS, AND/OR <br />CHASES, WHERE APPLICABLE. <br />9. INSTALL CODE APPROVED PENETRATIONS THROUGH FIRE <br />WALLS. <br />10. PROVIDE COMPLETED REFRIGERATION SENSOR INPUT <br />VERIFICATION FORMS TO OWNER'S BUILDING AUTOMATION <br />SYSTEM AND THE BAS SUPPLIER AT THE BEGINNING OF THE <br />REFRIGERATION EQUIPMENT START-UP. PROVIDE ASSISTANCE <br />TO THE BAS SUPPLIER FOR CHECKING SENSOR ACCURACY. <br />11. BE PRESENT AND AVAILABLE AT REFRIGERATION START-UP TO <br />RESOLVE ISSUES AND PROVIDE ASSISTANCE UNTIL RELEASED <br />BY THE BAS SUPPLIER AND OWNER'S MECHANICAL <br />CONSTRUCTION MANAGER. <br />12. COMPLETE ALL UNRESOLVED REFRIGERATION WORK, DURING <br />THE REFRIGERATION START-UP, PRIOR TO WORKING ON OTHER <br />BAS INSTALLATION ITEMS. <br />13. PERFORM ALL CHECKS AND TESTS TO ENSURE A FULLY <br />FUNCTIONAL REFRIGERATION CONTROL SYSTEM WHEN THE BAS <br />SUPPLIER IS NOT SCHEDULED TO PERFORM THE ON -SITE <br />REFRIGERATION START-UP. CONTACT THE BAS SUPPLIER FOR <br />BLANK TEST VERIFICATION FORMS AND INSTRUCTIONS FOR <br />COMPLETING. RETURN ALL COMPLETED TEST VERIFICATION <br />FORMS TO THE BAS SUPPLIER. <br />14. 24 HOURS PRIOR TO SHUTTING DOWN ANY REFRIGERATION <br />SYSTEMS, HVAC SYSTEMS, OR BUILDING AUTOMATION CONTROL <br />SYSTEMS, SEND AND E-MAIL TO NSRM@WALMART.COM. THE <br />E-MAIL SHALL STATE WHAT, WHY, AND WHEN IT IS BEING SHUT <br />DOWN AND HOW LONG IT IS ANTICIPATED TO BE DOWN. THEN <br />SEND A FOLLOW UP E-MAIL TO NSRM@WALMART.COM AFTER <br />THE WORK IS COMPLETED AND THE SYSTEM IS BACK UP AND <br />RUNNING. <br />15. REFER TO FIXTURE DRAWINGS FOR PIPING INSTALLATION AND <br />SEALING REQUIREMENTS FOR DEVICES SHOWN ON <br />COOLER/FREEZER PANELS. DO NOT INSTALL PIPING WITHIN <br />COOLER/FREEZER PANELS. <br />16. ROUTE ALL UTILITY SERVICE LINES (PIPES AND CONDUIT) WITHIN <br />STUD WALLS WHEREVER POSSIBLE. ON COOLER/FREEZER <br />PANELS IN FOOD PREP AREAS WHERE UTILITIES MUST BE <br />EXPOSED, CONTRACTOR TO HAVE THE OPTION OF THE <br />FOLLOWING: <br />A. SURFACE MOUNT UTILITIES WITH NOW CORROSIVE <br />ANCHORS; SEAL BOTH SIDES OF PIPE/CONDUIT TO PANEL <br />CONTINUOUSLY WITH SEALANT. <br />B. INSTALL UTILITIES 1/2" OFF FACE OF PANEL TO ALLOW FOR <br />CLEANING; USE ONLY NOW CORROSIVE MATERIALS FOR <br />SPACERS AND ANCHORS. <br />C. COVER UTILITIES WITH 20 GAUGE STAINLESS STEEL BENT <br />PLATES MOUNTED TO WALL WITH NON -CORROSIVE <br />ANCHORS; APPLY CONTINUOUS SEALANT ALONG EDGES AND <br />JOINTS. <br />BAS EQUIPMENT SALVAGE <br />REQUIREMENTS <br />CX-0425.22 <br />ALL DEMOLISHED NOVAR EMS EQUIPMENT SHALL BE RETURNED TO <br />OWNER'S MECHANICAL CONSTRUCTION MANAGER. EQUIPMENT TO <br />BE RETURNED INCLUDES: EXECUTIVE CONTROLLER(S), IOM(S), <br />CIM(S), CCM(S), ETC. PROVIDE DOCUMENTATION FOR ALL <br />EQUIPMENT REMOVED IN ACCORDANCE WITH SPECIFICATIONS AND <br />REQUIRED CLOSE-OUT DOCUMENTS. <br />CONTRACTOR SHALL SEND EQUIPMENT TO ASSET TECHNOLOGIES <br />AT THE ADDRESS BELOW. CONTRACTOR SHALL APPLY FOR CHANGE <br />ORDER FOR SHIPPING REIMBURSEMENT. BEFORE SENDING, CALL <br />FOR "RMA" NUMBER AT 502-425-8702. <br />3600 CHAMBERLAIN LANE <br />STE. 122, LOUISVILLE, KY 40241 <br />CASE BAS SETPOINTS <br />CX-02.27.20 <br />CONTRACTOR SHALL UPDATE BAS SETPOINTS IN RACK <br />CONTROLLERS FOR CIRCUITS WITH NEW REFRIGERATED CASES <br />CONTACT CASE VENDORS LISTED ON SHEET T1 FOR CASE BAS <br />SETPOINT CUTSHEET INFORMATION. <br />0 <br />O LO zuiO W W <br />" <br />W <br />No��zH�C7zu <br />�-zw~�wazz <br />c� =��WLLcoo�w° <br />as ��oQwa�z0w <br />m <br />O <br />LL <br />wL roa��aw<0 <br />H z z¢ 2 O 2 a r <br />O <br />U wwWW� <br />�Va �=°�z <br />~ <br />zoDo?°z <br />Uw (6 < 0�w ¢ W Ulf 00¢ <br />Zviw 00gzo0< <W <br />� <br />�zC �zJU�JLli �w cE§ <br />W <br />oLL, Lu<=�=zx0=a <br />) (L ZP- 0�¢¢OWdDHW <br />°U0ccna-0w�71ofofC� <br />FmrWi <br />Z <br />0 <br />_ <br />O <br />0 <br />o <br />QD <br />� <br />w <br />,_ <br />- � M <br />w <br />LL <br />cn � rn <br />Z <br />m N <br />Lu <br />W Luu.iox <br />Z <br />wpm <br />Q w <br />> C /) Q <br />W <br />Z N <br />Z Z <br />�YLL <br />Z <br />O <br />}c q <br />o U <br />ocr <br />W <br />L,o <br />Z <br />Z <br />wzLn <br />w <br />N�� <br />CDC <br />~ <br />LLI <br />wJ� <br />Z <br />of <br />J <br />-i <br />l!) 7 <br />W <br />J <br />z <br />M <br />LL <br />Z <br />00 <br />O <br />Lu <br />U <br />, <br />O <br />m <br />O <br />00 U d <br />C__D C=--) LL <br />J U <br />00 <br />V) p p <br />J C:) <br />J �I co n. <br />0 oN <br />Z O <br />0 <br />Z o <br />Wio� o <br />0 N <br />W <br />0� <br />W <br />N w <br />W <br />m <br />ISSUE BLOCK <br />CHECKED BY: KK/JPL <br />DRAWN BY: MJS <br />DOCUMENT DATE: 06/30/23 <br />THIS ITEM HAS BEEN <br />ELECTRONICALLY SIGNED <br />AND SEALED BY MICHAEL <br />DEAN SCHAEFER ON THE <br />DATE LISTED BELOW <br />USING A DIGITAL <br />SIGNATURE. <br />PRINTED COPIES OF THIS <br />DOCUMENT ARE NOT <br />CONSIDERED SIGNED AND <br />SEALED AND THE <br />SIGNATURE MUST BE <br />VERIFIED ON ANY <br />ELECTRONIC COPIES. <br />MICHAEL D. SCHAEFER <br />LICENSE # 89591 <br />.... � fIle <br />It <br />819591 •�# <br />.o • 7t <br />i STATE <br />06/30/2023 <br />REFRIGERATION <br />BUILDING <br />AUTOMATION <br />SYSTEM PLAN <br />n, <br />w <br />w <br />w <br />Q <br />U <br />U) <br />0 <br />J <br />w <br />Q <br />U <br />5 <br />REFRIGERATION BUILDING AUTOMATION SYSTEM PLAN <br />1 1 /16" = V-0" <br />[EXISTING CONDITIONS WERE TAKEN FROM <br />ORIGINAL DRAWINGS AND MAY NOT REFLECT <br />EXACT "AS -BUILT" CONDITIONS. CONTRACTOR <br />SHALL FIELD VERIFY ALL EXISTING CONDITIONS <br />PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR <br />SHALL CAREFULLY COORDINATE NEW WORK AND <br />DEMOLITION WITH ALL OTHER DISCIPLINES AND <br />EXISTING CONDITIONS. <br />EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING <br />A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br />SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE <br />TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES <br />NOT RELIEVE THE RESPONSIBILITY OF PERFORMING <br />THE WORK PROPERLY. NO ADDITIONAL <br />COMPENSATION SHALL BE ALLOWED BECAUSE OF <br />CONDITIONS THAT OCCUR DUE TO FAILURE TO <br />FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. <br />HFFT- <br />BASR1� <br />