_ <br />NOVAR TELEPHONE <br />BACKBOARD BACKBOARD <br />J H1B2 H1A FIRE ALARM <br />Liu BACKBOARD <br />ELECTRICAL MSWB <br />L1 D2 ROOM 1 <br />H1P1 <br />10 T1D2 LID T1D H1B1� H1P2 <br />B - (15A-3P) EXISTING #12 <br />16.270 <br />T36 H 1 A-61,63,65 ❑ <br />L313 H3B (20A-3P) 16.239 Q <br />L3P 16.239 16.270 WP/WR <br />H1A-555759 <br />L3D2 REPLACE <br />H3P,, � <br />WP/W EXISTING #12 <br />L3D1 H3A <br />ELECTRICAL ❑ REPLACE <br />ROOM 3 I RTU-29 <br />ELECTRICAL ROOM 3 PLAN <br />REAR ENLARGED POWER PLAN <br />5 <br />WPMR <br />16.239 <br />❑ (20A-3P) <br />16.274 <br />_j3y- <br />H3A-26,28,30 <br />NEW (3)-#8 <br />REPLACE & (1)-#8G <br />RTU-4 IN NEW 3/4"C <br />(APPROX. 275') <br />1 2 3 4 5 6 7 8 9 <br />2 <br />E1 <br />REPLACE RTU-32 <br />I REFURBISH �) I <br />RTU-34 <br />REFURBISH REFURBISH (2 .3P) (20A-3P) <br />RTU-28 - - - I RTU-30 16.270 _ 16.273 <br />_-_-_ _-_-_-_- _-_-_-_ <br />- --_ - - <br />_ H1A-56,58,60 H1A-62,64,66 <br />_ _. EXISTING #12 REPLACE RTU-33 <br />H-I - - - -I - I- --I - i - - i- - - --4-WPMR WPMR- - <br />' EXISTING #12 <br />I ( 16.239 <br />(:G <br />1 I ETR <br />RE1.1 � AHU-2 <br />REFURBISH REFURBISH <br />I i I RTU-24 ( RTU-25 <br />I i <br />( _ I <br />I I I I I I I I I I I <br />ETR <br />REFURBISH AHU-3 <br />RTU-22 <br />6 <br />WPMR WPMR <br />F]16.239 16.239 <br />(20A-3P) (20A-3P) <br />Oy-16.274 ❑ 16.274 <br />H3A-31,33,35 H3A-32,34,36 <br />NEW (3)-#8 NEW (3)48 <br />REPLACE & (1)-#8G REPLACE & (1)-#8G <br />RTU-5 IN NEW 3/4"C RTU-6 IN NEW 3/4"C <br />(APPROX. 253') (APPROX. 233') <br />r4� FRONT �ENLARGED POWER �PLAN <br />10 11 12 13 14 <br />REFURBISH <br />RTU-35 <br />I I I I I <br />I I I I I <br />- - + - (40A-3P) <br />EXISTING #6 - - - <br />16.270 <br />H 1 A-43,45,47 <br />REFURBISH I n REPLACE <br />RTU-26 16.239 RTU-271 <br />WP/WR <br />I I I <br />I I I <br />REFURBISH <br />RTU-23 <br />(20A-3P) <br />1 I 16.270 I <br />H1A-49,51,53 <br />REPLRE1 I ICE EXISTING #10 I WP/WR <br />RTU- 3- 16.239 (60A-3P) - - -� - - - - - - - - - - 16.239 <br />WP/WR 16.270 (20A-3P) EXISTING #4 REPm RTU-1gCE <br />H1A-13,15,17 16.270 I REFURBISH I REFURBISH I REFURBISH <br />16.239 H1A-50,52,54 _ __ RTU-16 RTU-17 RTU-18 H3A-7,9,11 <br />WPMR EXISTING #4 EXISTING #10 I 16.273 <br />REPLACE m G WPMR _ REPLACE (80A-3P) <br />RTU-14 1 - ( RTU-12 WP/WR <br />i 16.239 <br />REPLACE 1 NEW (3)-#10 I <br />LRTU-15 (60A-3P) - - & (1)-#10G 16.239 (30A-3P) <br />- - - - - - - - - - - - - - - - 16.270 _ - - IN EXSTG 1/2"C EXISTING #12 H3A-43,45,47 16.271 <br />B - H1A-04,46,4�ISTING � - (�APPROX.152') REP <br />- 20A-3P) - - - <br />- - o I I REPLACE H3A-37,39,41 LACE & ( �10NEW G 0 <br />RTU-11 0 <br />16.239 RTU-8 16.239 IN EXSTG 1/2"C <br />RTU-REP1 EXISTING #6 (40A-3P) - - - ' - ' - - - - - - ' WPMR 16.239 (APPROX. 63') <br />WPMR n H1A-25,27,29 16Q270 0 �o o �o� n WP/WR a H3A-38,40,42 <br />WP/WRREP16270 <br />16.239 <br />RTU-2 CE I WP/WR REFURBISH I I I I 16.239 H3A-25,27,29 (20A-3P) 3 <br />RTU-3 - 16.270 E 1 <br />REPLACE ETR <br />RTU-9 RTU-10 <br />4 EXISTING #8 <br />E1 <br />POWER PLAN <br />30'-0" <br />J <br />W <br />O <br />m <br />0 <br />z <br />O <br />11 <br />ELECTRICAL SYMBOLS <br />LEGEND <br />GENERAL NOTES <br />07.26.19 <br />08.02.19 <br />(SYMBOLS APPLY ONLY WHEN USED ON DRAWINGS) <br />1. FURNISH AND INSTALL ALL MATERIALS, EQUIPMENT, AND LABOR, <br />FOR A COMPLETE INSTALLATION IN ALL RESPECTS, READY FOR <br />INTENDED USE AND IN STRICT ACCORDANCE WITH NEC, NESC, <br />SYMBOL <br />DESCRIPTION <br />M <br />MANUAL MOTOR RATED <br />DISCONNECT SWITCH <br />STATE, AND LOCAL CODES, AND MANUFACTURER'S <br />RECOMMENDATIONS. PAY ALL NECESSARY FEES AND PERMITS. <br />A. NO CIRCUITRY SHALL BE ALLOWED TO BE ROUTED ACROSS THE <br />ROOF OR THE EXTERIOR SIDE OF THE EXTERIOR WALLS. <br />B. ALL EQUIPMENT SHALL BE UL LISTED WHERE APPLICABLE. <br />RECEPTACLE, DUPLEX MOUNTED +42" <br />UNLESS NOTED OTHERWISE <br />RECEPTACLE, GFI DUPLEX MOUNTED <br />C. ARRANGE ALL WORK TO MINIMIZE DISRUPTIONS TO STORE <br />+42" UNLESS NOTED OTHERWISE <br />OPERATIONS. COORDINATE ALL DISRUPTIONS WITH WALMART <br />CONSTRUCTION MANAGER AND STORE MANAGER. COORDINATE <br />BETWEEN EXISTING AND NEW CONSTRUCTION. <br />D. CONTRACTOR SHALL VERIFY ALL WALL FINISH THICKNESS <br />JUNCTION BOX <br />(WALL MOUNTED/CEILING MOUNTED ) <br />O <br />THERMOSTAT <br />(WALL MOUNTED/CEILING MOUNTED) <br />BEFORE INSTALLING BOXES. FURNISH AND INSTALL EXTENDED <br />BOXES OR BOX EXTENDERS WHERE REQUIRED. <br />E. CONTRACTOR SHALL VERIFY THAT ALL AFFECTED <br />PANELBOARDS HAVE CIRCUIT BREAKER KNOCKOUTS <br />PROPERLY COVERED AND THAT ALL TRIM IS IN GOOD <br />O <br />ALARM JUNCTION BOX, <br />(WALL MOUNTED/CEILING MOUNTED) <br />® <br />ALARM JUNCTION BOX, <br />FOR REMOTE TEST/RESET <br />(WALL MOUNTED/CEILING MOUNTED) <br />CONDITION, ALLOWING NO ACCESS TO LIVE PARTS. <br />F. ALL NEW EXPOSED CONDUIT LOCATED IN PUBLIC AREAS TO BE <br />PAINTED TO MATCH ADJACENT SURFACE. <br />ADJACENT TO RTU SENSOR AT +74" UNO <br />2 PROVIDE SEALS AT RACEWAY PENETRATIONS AS FOLLOWS: <br />200/3/NF <br />A FIRE RATED WALLS: SEAL PER SPECIFICATIONS FOR FIRE <br />WP/WR <br />Eh <br />DISCONNECT SWITCH "200/3/150" <br />STOPPING. <br />4(:� 16.239 <br />20%3/150 <br />DENOTES AMPERES/POLE/FUSE <br />B. FREEZER/COOLER BOXES: SEAL WITH EXPANDING FOAM <br />(40A-3P) <br />E]16.271 <br />NF=NON-FUSED <br />SEALANT. <br />C. EXTERIOR: REFER TO RELATED SPEC. SECTIONS OF DIVISION 7 <br />H3A-20,22,24 <br />EQUIPMENT CONNECTION POINT <br />FOR SEALING REQUIREMENTS AT ALL EXTERIOR MOUNTED <br />(PROVIDED WITH EQUIPMENT) <br />DEVICES, FIXTURES, ENCLOSURES, AND RACEWAY <br />NEW (3)-#6 <br />PENETRATIONS. <br />CIRCUIT, CONCEALED IN WALLS OR <br />REPLACE & (1)-#8G <br />RTU-7 IN NEW 3/4"C <br />CEILING, E INDICATES EXISTING WIRING <br />3. WHERE EQUIPMENT NAMEPLATE PROTECTIVE DEVICE RATING <br />�_ - _ \ <br />CIRCUIT, CONCEALED IN SLAB FLOOR, <br />(APPROX. 209') <br />DIFFERS FROM SIZE PROVIDED. NOTIFY WALMART CONSTRUCTION <br />E INDICATES EXISTING WIRING MANAGER IMMEDIATELY TO COORDINATE RESOLUTION. <br />CIRCUIT, EXPOSED, 4. WIRING DEVICES: DEVICE MOUNTING HEIGHTS ARE FROM FINISHED <br />E INDICATES EXISTING WIRING FLOOR TO CENTER OF OUTLET BOX UNLESS NOTED OTHERWISE ON <br />------------ LOW VOLTAGE WIRING PLANS. <br />5. NEW ELECTRICAL CIRCUITS FOR THIS PROJECT SHALL BE ROUTED <br />= FLUSH MOUNTED PANELBOARD TO PANELBOARD AS INDICATED ON DRAWINGS. WIRING SHALL <br />INCLUDE FINAL CONNECTION TO ALL EQUIPMENT IN CONFORMANCE <br />SURFACE MOUNTED PANELBOARD WITH EQUIPMENT SUPPLIER WIRING DIAGRAMS. PROVIDE LIQUID - <br />TIGHT FLEXIBLE METAL CONDUIT AND WIRING FROM DISCONNECT <br />O SWITCH OR JUNCTION BOX TO EQUIPMENT KNOCKOUT OR <br />MOTOR ELECTRICAL CONNECTION POINT. CONTRACTOR SHALL CAREFULLY <br />COORDINATE THE INSTALLATION OF NEW EQUIPMENT WITH <br />Y PUSH BUTTON EXISTING CIRCUITING TO MINIMIZE DOWN TIME. <br />SAIL SWITCH 6. CONTRACTOR IS RESPONSIBLE FOR PROVIDING COMPLETE <br />SS JUNCTION BOX PANELBOARD IDENTIFICATION SCHEDULES FOR PANELBOARDS <br />AFFECTED BY ELECTRICAL WORK. <br />ABBREVIATIONS <br />7. CONTRACTOR SHALL VERIFY THAT THE PANELBOARDS USED TO <br />AF AMPERE FUSE SUPPLY POWER TO THE NEW LOADS HAS THE SPACE AND <br />AFF ABOVE FINISHED FLOOR AMPACITY TO DO SO PRIOR TO ROUGH -IN. NEW CIRCUIT BREAKER <br />AFG ABOVE FINISHED GRADE OR OVERCURRENT PROTECTIVE DEVICES INSTALLED IN EXISTING <br />AS AMPERE SWITCH PANELBOARDS OR DISTRIBUTION BOARDS SHALL MATCH THE <br />C CONDUIT MANUFACTURER, TYPE AND AIC RATING OF EXISTING CIRCUIT <br />CCT CIRCUIT BREAKER OR OVERCURRENT PROTECTIVE DEVICES. IF EXISTING <br />CF CEILING FAN CIRCUIT BREAKERS IN A PANELBOARD OR SWITCHBOARD HAVE <br />EF EXHAUST FAN DISIMILAR RATINGS, PROVIDE THE NEW CIRCUIT BREAKER(S) TO <br />ETR EXISTING TO REMAIN MATCH TO THE HIGHEST AIC RATING FOUND IN THAT BOARD. <br />GFCI GROUND FAULT CIRCUIT INTERRUPTER <br />GND GROUND 8. BRANCH CIRCUIT CONDUCTORS SHALL BE MINIMUM #12 AWG <br />HD HAND DRYER UNLESS NOTED OTHERWISE IN SCHEDULES. WHERE 20A BRANCH <br />NTS NOT TO SCALE CIRCUITS HAVE #8 AND LARGER WIRE SPECIFIED, #10 AWG WIRE <br />RH RADIANT HEATER SHALL BE USED FOR THE FINAL CONNECTION (15-FT MAXIMUM). <br />TYP TYPICAL <br />UH UNIT HEATER 9. WHERE BRANCH CIRCUITS ARE GROUPED, SIZE CONDUIT AND <br />LINO UNLESS NOTED OTHERWISE DERATE CURRENT CARRYING CONDUCTORS PER NEC. <br />15 W WIRE <br />WH WATER HEATER 10. PROVIDE UL LISTED HANDLE TIES ON ALL MULTIWIRE BRANCH <br />WP WEATHER PROOF CIRCUITS PER NEC REQUIREMENTS. <br />WR WEATHER RESISTANT <br />11. SUPPORTS FROM STRUCTURE: NO ATTACHMENT OF ANY TYPE <br />SHALL BE MADE TO BRIDGING OR JOIST WEB MEMBERS. UTILIZE <br />KEYNOTES ONLY THE TOP AND BOTTOM CHORDS FOR SUPPORTING THE <br />ELECTRICAL SYSTEM INSTALLATIONS. <br />12. ONLY FEEDER CIRCUITS NOTED ON THE ONE LINE DIAGRAM AND <br />16.239 CONNECT CIRCUITY TO FACTORY PROVIDED BRANCH CIRCUITS NOTED BY LEGEND SHALL BE INSTALLED UNDER <br />MAINTENANCE RECEPTACLE. ROUTE CIRCUIT TO SLAB. PROVIDE EXTERIOR COATED GRC BENDS ON ALL CONDUIT <br />NEAREST RTU, IF AVAILABLE, OR NEAREST RUNS THAT HAVE 45 DEGREE BENDS OR GREATER. REFER TO <br />PANELBOARD SUPPLYING CONVENIENCE SPECIFICATION SECTION 16.100 FOR UNDER SLAB. <br />RECEPTACLES AND INSTALL NEW CIRCUIT 13. SEISMIC ZONE REQUIREMENTS: PROVIDE EXPANSION COUPLINGS <br />BREAKER. AND BRACING FOR ELECTRICAL EQUIPMENT AS REQUIRED BY <br />16.270 EXTEND EXISTING FEEDER AND CONNECT TO LOCAL CODES. <br />- NEW REPLACEMENT RTU. RE -USE EXISTING <br />CIRCUIT BREAKER IN PANELBOARD. NEW RTU 14. EXISTING ELECTRICAL AND ALARM: <br />COMES COMPLETE WITH HACR BREAKER FOR A. WHERE DEMOLITION OR NEW CONSTRUCTION INTERRUPTS <br />LOCAL DISCONNECT AND OVERCURRENT EXISTING ELECTRICAL CIRCUITS FEEDING EXISTING EQUIPMENT, <br />PROTECTION. ELECTRICAL CONTRACTOR TO DEVICES, OR LIGHTING TO REMAIN, BUT NOT SHOWN ON <br />VERIFY EXISTING CONDITION OF CONDUCTORS. DRAWINGS, PROVIDE LABOR AND MATERIALS TO REWORK <br />RECONNECT EXISTING BAS CONTROLS CIRCUITRY, AS REQUIRED, TO MAINTAIN EXISTING OPERATION. <br />CIRCUITRY TO NEW CONTROLLER IN RTU. B. IF DEMOLITION OR NEW CONSTRUCTION WILL DISRUPT <br />ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING UNDERGROUND SERVICES (ELECTRICAL, TELEPHONE, <br />EXISTING CONDITION OF SENSOR CABLE. ALL PARKING LOT LIGHTING CIRCUITRY, ETC.) PROVIDE ALL <br />BAS CONTROLS EQUIPMENT SHALL BE MATERIALS AND LABOR AS REQUIRED TO REROUTE, SLEEVE, <br />SALVAGED FROM EXISTING RTU'S BY THE OR OTHERWISE REWORK THESE SERVICES TO MAINTAIN THEIR <br />- - MECHANICAL CONTRACTOR AND RETURNED TO EXISTING OPERATION. <br />THE SAM'S CLUB CONSTRUCTION MANAGER. C. EXERCISE CAUTION AROUND ALARM AND SECURITY CABLES <br />16.271 PROVIDE NEW WIRE IN EXISTING CONDUIT, DURING DEMOLITION AND CONSTRUCTION. PROTECT ALARM <br />SIZED AS INDICATED, AND CONNECT TO NEW AND SECURITY CABLES FROM ACCIDENTAL DAMAGE SO THAT <br />REPLACEMENT RTU. RE -USE EXISTING CIRCUIT SYSTEMS REMAIN OPERATIONAL AT ALL TIMES. <br />BREAKER IN PANELBOARD. NEW RTU COMES D. DISPOSE OF ALL REMOVED MATERIALS, UNLESS OTHERWISE <br />COMPLETE WITH HACR BREAKER FOR LOCAL NOTED. <br />DISCONNECT AND OVERCURRENT PROTECTION. <br />RECONNECT EXISTING BAS CONTROLS 15. EXISTING ELECTRICAL DEMOLITION: <br />CIRCUITRY TO NEW CONTROLLER IN RTU. A. GENERAL: REMOVE OR RELOCATE EXISTING ELECTRICAL <br />ELECTRICAL CONTRACTOR SHALL VERIFY EQUIPMENT, CONDUIT AND CONDUCTORS AS INDICATED ON <br />- EXISTING CONDITION OF SENSOR CABLE. ALL THE DRAWINGS, OR ONLY AS REQUIRED BY DEMOLITION. <br />BAS CONTROLS EQUIPMENT SHALL BE REMOVE ALL PANELBOARDS, DISCONNECT SWITCHES, BOXES, <br />SALVAGED FROM EXISTING RTU'S BY THE RELAYS, TIME SWITCHES, LIGHTS, DEVICES, ETC., WHICH WILL <br />MECHANICAL CONTRACTOR AND RETURNED TO NOT BE REUSED. <br />THE SAM'S CLUB CONSTRUCTION MANAGER. B. SALES FLOOR: EXISTING CONDUIT AND CONDUCTORS MAY BE <br />16.271A PROVIDE NEW WIRE IN EXISTING CONDUIT, REUSED FOR NEW POWER CIRCUITS WHERE SIZE, RATING, AND <br />SIZED AS INDICATED, AND CONNECT TO NEW CONDITION MEET REQUIREMENTS INDICATED ON PLANS AND <br />REPLACEMENT RTU. REPLACE EXISTING ALL U.L. RATINGS. REMOVE ALL UNUSED CONDUIT AND <br />CIRCUIT BREAKER IN PANELBOARD. NEW RTU CONDUCTORS BACK TO POINT OF ORIGIN WHENEVER FEASIBLE <br />COMES COMPLETE WITH HACR BREAKER FOR AND RELABEL DEMOLISHED CIRCUITS AS "SPACE". REMOVE <br />LOCAL DISCONNECT AND OVERCURRENT CIRCUIT BREAKER AND REPLACE WITH FILLER PLATE. UPDATE <br />PROTECTION. RECONNECT EXISTING BAS TYPEWRITTEN CIRCUIT DIRECTORY IDENTIFYING CIRCUIT AS <br />CONTROLS CIRCUITRY TO NEW CONTROLLER IN "SPACE". <br />RTU. ELECTRICAL CONTRACTOR SHALL VERIFY C. CONDUIT AND WIRING TO BE ABANDONED IN CEILING SPACES <br />EXISTING CONDITION OF SENSOR CABLE. ALL AND OTHER NON-PUBLIC AREAS (I.E., THROUGH STOCKROOM <br />BAS CONTROLS EQUIPMENT SHALL BE AREA): CUT WIRING LOOSE AND REMOVE FROM RACEWAY(S), <br />SALVAGED FROM EXISTING RTU'S BY THE LEAVING RACEWAY(S) IN PLACE. CONDUIT TO BE ABANDONED IN <br />- - - - MECHANICAL CONTRACTOR AND RETURNED TO WALLS OR FLOORS SHALL BE REMOVED BACK TO FINISHED <br />THE SAM'S CLUB CONSTRUCTION MANAGER. SURFACE AND CAPPED INSIDE. REPAIR SURFACE(S) TO MATCH <br />M 16.273 EXTEND EXISTING FEEDER AND CONNECT TO ADJACENT. <br />NEW REPLACEMENT RTU. REPLACE EXISTING D. ALL CIRCUIT BREAKERS SERVING BRANCH CIRCUITS TO BE <br />CIRCUIT BREAKER IN PANELBOARD. NEW RTU REMOVED SHALL ALSO BE REMOVED. REMOVE CIRCUIT <br />COMES COMPLETE WITH HACR BREAKER FOR <br />BREAKER AND REPLACE WITH FILLER PLATE. UPDATE <br />REFURBISH I LOCAL DISCONNECT AND OVERCURRENT TYPEWRITTEN CIRCUIT DIRECTORY IDENTIFYING CIRCUIT AS <br />RTU-20 PROTECTION. RECONNECT EXISTING BAS "SPACE". <br />CONTROLS CIRCUITRY TO NEW CONTROLLER IN E. DISPOSAL OF ALL DECOMMISSIONED EQUIPMENT, NOT <br />RTU. ELECTRICAL CONTRACTOR SHALL VERIFY APPORTIONED TO WALMART'S DESIGNATED SALVAGE VENDOR, <br />EXISTING CONDITION OF SENSOR CABLE. ALL SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR IN <br />BAS CONTROLS EQUIPMENT SHALL BE ACCORDANCE WITH RELATED SECTIONS OF THE <br />SALVAGED FROM EXISTING RTU'S BY THE SPECIFICATIONS, LOCAL CODES, AND ANY GOVERNMENTAL <br />MECHANICAL CONTRACTOR AND RETURNED TO REGULATIONS. THE CONTRACTOR SHALL COORDINATE THE <br />THE SAM'S CLUB CONSTRUCTION MANAGER. PICK-UP DATE WITH THE DESGNATED SALVAGE VENDOR, <br />PREPARE AND LOAD THE DESIGNATED SALVAGE ITEMS, <br />16.274A PROVIDE NEW WIRE AND CONDUIT, SIZED AS KEEPING THEM INTACT. REFER TO MECHANICAL DRAWINGS FOR <br />INDICATED AND CONNECT TO NEW RTU. RE -USE EQUIPMENT BEING REMOVED. <br />EXISTING CIRCUIT BREAKER IN PANELBOARD. F. BUILDING COMPONENTS ABANDONED BY THE SCOPE OF WORK <br />NEW RTU COMES COMPLETE WITH HACR SHALL BE SECURED TO PREVENT FALLING, LOOSENING, OR <br />BREAKER FOR LOCAL DISCONNECT AND CREATING DAMAGE OF ANY KIND IN THE FUTURE. <br />OVERCURRENT PROTECTION. RECONNECT <br />EXISTING BAS CONTROLS CIRCUITRY TO NEW 16. ETHERNET CABLE: <br />CONTROLLER IN RTU. ELECTRICAL CONTRACTOR A. FURNISH AND INSTALL JUNCTION BOXES AS SHOWN ON PLANS. <br />SHALL VERIFY EXISTING CONDITION OF SENSOR <br />CABLE. ALL BAS CONTROLS EQUIPMENT SHALL PROVIDE CONDUIT AS REQUIRED BY LOCAL CODES AND/OR <br />BE SALVAGED FROM EXISTING RTU'S BY THE ORDINANCES. <br />MECHANICAL CONTRACTOR AND RETURNED TO B. ETHERNET CABLE IS FURNISHED BY OTHERS. <br />THE SAM'S CLUB CONSTRUCTION MANAGER. C. ELECTRICAL CONTRACTOR SHALL INSTALL OTHER CABLE AS <br />DIRECTED BY WALMART CONSTRUCTION. <br />17. ELECTRONIC FIRE PROTECTION/SECURITY ALARM BOXES AND <br />CONDUITS SHOWN ON POWER PLANS SHALL BE PROVIDED UNDER <br />THIS CONTRACT. IN ADDITION, UNLESS NOTED OTHERWISE, THE <br />FOLLOWING GENERAL NOTES APPLY. <br />A. ALL ALARM JUNCTION BOXES SHALL BE 4"X4"X2-1/8" MINIMUM. <br />I B. ALARM RACEWAYS SHALL BE 3/4" MINIMUM WITH PULL WIRE AND <br />INSULATING BUSHINGS AT END OF VERTICAL RACEWAY RUN. <br />C. VERTICAL RACEWAYS FROM ALARM BOXES SHALL BE EITHER <br />CONCEALED INSIDE WALL OR SURFACE MOUNTED (TO MATCH <br />JUNCTION BOX MOUNTING). ALL VERTICAL RUNS SHALL BE <br />TURNED 90-DEGREES AT TOP SIDE OF BOTTOM CHORD OF <br />JOIST AND EXTENDED HORIZONTALLY TO A LOCATION <br />ACCESSIBLE BY VERTICAL FLOOR TYPE LIFT. <br />18. UPON COMPLETION OF ELECTRICAL INSTALLATION AND PRIOR TO <br />ENERGIZING CIRCUIT: <br />NOTE: ALL WORK ON THIS SHEET TO BE A. INSPECT WIRE AND CABLE FOR PHYSICAL DAMAGE. <br />COMPLETED BY AN OWNER APPROVED B. PERFORM CONTINUITY TEST. <br />CONTRACTOR. C. VERIFY PROPER PHASING CONNECTION TO ALL THREE PHASE <br />MOTOR LOADS. <br />EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL <br />MAY NOT REFLECT EXACT "AS -BUILT" CONDITIONS. CONTRACTOR SHALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT <br />FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL THEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING <br />BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND THE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF <br />DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. <br />W y FDo WWRO� <br />m w <br />j U. m�-w�ZF 0 N <br />p F'O'wf"w8,z <br />W w xZLL��'awQ3U0 <br />� aQ 3�Q�WO�pZOZOwU <br />w Q <br />LLO WuJ ?¢paOLL=UV1-�Q <br />z Qv wa '-wW LLWM <br />O ;LLLL WNwg ZONFOxp <br />W x Z o 2 <br />g gctdpot=gzx �W <br />3Q=aZ�FpUjU) ni <br />i V(1) wwpo0 � <br />d pzp wo a�cn WH <br />H Dwaz�COFdWa�Fw <br />xfdW oQpww WUwwnx <br />CO HMNUp00.0 WJww<F- <br />0 <br />q <br />U) �/ <br />(M <br />N <br />p <br />Ix cn <br />W <br />1= �` <br />W <br />W <br />co <br />10 ,n <br />d' <br />NNE <br />rn <br />Z <br />WO <br />cl W <br />coo x <br />W Q <br />O <br />Z <br />,� cv <br />pQN <br />O <br />o�CO <br />Wo <br />o <br />w <br />N�W <br />z <br />T z <br />2 W <br />wz,r, <br />Spa. <br />w <br />cDa <br />w <br />w -i <br />Z <br />rLf)�i <br />= <br />i <br />z <br />O <br />co -i <br />LU <br />O <br />m <br />O <br />00 JCL <br />CO co �.L <br />a0 <br />p OJ CD <br />co a J <br />O N <br />O o <br />Z o <br />W O <br />0 N <br />0 � H <br />00 <br />W <br />N W m <br />M <br />z <br />m <br />O <br />- - - -3 <br />ISSUE BLOCK <br />CHECKED BY: JDS <br />DRAWN BY: RR <br />DOCUMENT DATE: 06/30/23 <br />THIS ITEM HAS BEEN <br />ELECTRONICALLY SIGNED <br />AND SEALED BY JOHN D. <br />STOWELL ON THE DATE <br />LISTED BELOW USING A <br />DIGITAL SIGNATURE. <br />PRINTED COPIES OF THIS <br />DOCUMENT ARE NOT <br />CONSIDERED SIGNED AND <br />SEALED AND THE <br />SIGNATURE MUST BE <br />VERIFIED ON ANY <br />ELECTRONIC COPIES. <br />JOHN D. STOWELL <br />LICENSE # 91727 <br />`1111111111/111', <br />,, <br />E N <br />No. 91727 <br />fr+ <br />4 <br />3 STATE OF : u <br />s�talaall 1� <br />06/30/2023 <br />POWER PLANS <br />SHEET: <br />E 1 <br />