ROOF DECK - <br />CONTINUE <br />PLYWOOD <br />TO DECK - <br />SALES <br />1/2" CD PLYWOOD <br />4'-0"X8'-0" HORIZONTAL <br />PROVIDE 2X4 NAILER <br />AT ALL JOINTS <br />INSTALL CONTINUOUS <br />LAYER 6 MIL POLY <br />SHEETS TAPE ALL <br />JOINTS <br />2X4 AT 24" OC <br />PAINT DUST WALLS TO <br />MATCH ADJACENT IF <br />DUST WALLS TO BE IN <br />PLACE MORE THAN TWO <br />WEEKS. COORDINATE <br />WITH OWNER'S <br />CONSTRUCTION <br />MANAGER. <br />DO NOT USE DUSTWALL <br />TO SHORE ROOF JOISTS <br />WALL TO BE REMOVED <br />6-0" LOAD BEARING <br />4'-0" ELSEWHERE <br />NOTES: <br />1. INSTALL TEMPORARY WALL IN <br />SECTIONS APPROXIMATELY <br />40'-0" PER DAY (COORDINATE <br />WITH STORE MANAGER AND <br />OWNER'S CONSTRUCTION <br />MANAGER) <br />2. LOCATE VERTICAL 2X4'S AS <br />NOT TO IN INTERFERE WITH <br />CEILING GRID OR LIGHT <br />FIXTURES. <br />3. LOCATE HORIZONTAL 2X4 AT <br />2" ABOVE CEILING EXCEPT <br />LIGHT FIXTURE LOCATIONS. <br />4. SCREW PLYWOOD (MAX <br />SPACING 12" OC) <br />SEALANT UNDER CONTINUOUS SEALANT <br />BOTTOM PLATE AGAINST PLATE <br />ANCHOR AT 24" OC COORDINATE W/SPECIFICATIONS <br />SECTION 01500. <br />.DUST WALL SECTION <br />NTS 01.25.19 <br />C <br />2 3 4 <br />2.13 <br />I (TYP) <br />I REMOVE COFFIN <br />CASES TO BE <br />Q REPLACED <br />EXISTING I U <br />MEAT HOLDING I g <br />COOLER ( Lau - <br />co <br />Ij III <br />I I o I Ij III <br />w I Ij III <br />I II <br />EXISTING I � I I IJJJII <br />SEAFOOD I U I 2.14 I III <br />COOLER i w i (TYP) I �I <br />E <br />w I� III <br />I 'o <br />I w I I� III <br />I I I I II <br />SEAFOOD I I <br />PREP <br />REMOVE <br />�f EXISTING <br />/ WEDGE <br />/ REMOVE <br />SEAFOOD CASE <br />/ TO BE REPLACED <br />EXISTING <br />1 SEAFOOD <br />�1 BUNKER TO <br />REMAIN <br />I <br />I LT 1 I <br />I T REMOVE REACH -IN <br />- I SEAFOOD CASES <br />TO BE REPLACED <br />2.13 <br />(TYP) <br />EXISTING <br />REACH -IN <br />FROZEN <br />CAKE CASE <br />TO REMAIN <br />2.13 <br />(TYP) <br />2.13 <br />2.14 <br />2.13 - 2. 33 <br />(TYP) �� ��'��'� �r �!'�!'� '� '�� '�!'�` '�!'� �! '�� '� '�� '�� (TYP) <br />IX/ I III I REMOVE REACH -IN FROZEN FOOD CASES TO BE REPLACED <br />1</ lu-------------- I - - - - - - - I - - - - - - - - - - - - - - <br />-----�I 1 <br />� ______ <br />REMOVE REACH -IN FROZEN FOOD CASES TO BE REPLACED III -T1 <br />_y y y _y _y _y _y _y _y _y _y _y _y _y _y _y _y _y _y <br />2.13 _ _ <br />(TYP) (TYP) <br />1� REMOVE REACH -IN FROZEN FOOD CASES TO BE REPLACED I ► III I �` <br />REMOVE REACH -IN FROZEN FOOD CASES TO BE REPLACED I />1, <br />y y y y y y y y y y y y y y y y y y y y y y y y y y y y <br />2.13 <br />(TYP) _ 2.13 <br />X\ X\ '� '� '� '� '� '� '� '� '� '� '� (TYP) <br />�x/ REMOVE REACH -IN ICE CREAM CASES TO BE REPLACED <br />EXISTING MULTI -DECK PRODUCE CASES TO REMAIN ► I I % <br />ALL EXISTING REFRIGERATED <br />CASES ARE TO REMAIN <br />UNLESS OTHERWISE NOTED <br />EXISTING <br />SELF-CONTAINED <br />DELI CASE <br />TO REMAIN <br />EXISTING <br />SERVICE <br />DELICASES <br />REMOVE 3-DECK CAKE <br />CASES TO BE REPLACED <br />L - 1-------� <br />CAKE DECORATING <br />TO REMAIN <br />SERVICE <br />DELI <br />BAKERY <br />EXISTING <br />PRODUCE CASES <br />TO REMAIN --/ <br />REMOVE DELI <br />PROMO ISLAND <br />TO BE REPLACED 2.13 <br />- - - (TYP) <br />EXISTING - - - - <br />HOT DELI <br />CASES <br />TO REMAIN <br />2.13 <br />f REMOVE MULTI -DECK DELI <br />CASES TO BE REPLACED �u REMOVE <br />MULTI -DECK <br />r - 7 DELI CASE <br />TO BE REPLACED <br />DELI PREP EXISTINGDELI COOLER I <br />I I <br />L-� <br />FRONT DEMOLITION PLAN <br />1 1/8" = 1'-0" <br />KEYNOTES <br />1. <br />REMOVE EXISTING CORNER GUARDS. PATCH AND REPAIR <br />FLOOR AS NECESSARY. <br />REMOVE EXISTING CART STOP. PATCH AND REPAIR FLOOR 2. <br />AS NECESSARY. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10 <br />11 <br />DEMOLITION REQUIREMENTS <br />CX-04 08 20 <br />ALL DEMOLITION SHALL BE CARRIED OUT IN A SAFE MANNER <br />AND IN STRICT ACCORDANCE WITH OSHA REGULATIONS. <br />THE CONTRACTOR SHALL FIELD VERIFY THE EXTENT OF <br />DEMOLITION. THE WORK INCLUDES, BUT IS NOT LIMITED TO, THE <br />DEMOLITION AND REMOVAL OF WALLS, DOORS, FLOORS, AND <br />ELECTRICAL ITEMS INCLUDING CONDUITS AS SHOWN ON <br />DRAWING OR AS REQUIRED FOR THE INSTALLATION OF NEW <br />WORK FOR A COMPLETE JOB. <br />WHEN UTILITIES ARE REMOVED, CAP AND SEAL A MINIMUM OF 8" <br />BELOW FINISH FLOOR OR A MINIMUM OF 6" ABOVE FINISHED <br />CEILING. SHOW ALL ABANDONED AND CAPPED UTILITIES ON AS- <br />BUILTS, DRAWINGS, AND RECORDED DOCUMENTS. <br />IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE <br />ADEQUATE SHORING. BRACING, AND SUPPORT SYSTEMS AND TO <br />KEEP THE EXISTING STRUCTURE INTACT AND IN A SAFE <br />CONDITION DURING THE REMOVAL OF STRUCTURAL ITEMS AND <br />NEW CONSTRUCTION. <br />THE CONTRACTOR SHALL RETAIN A REGISTERED <br />PROFESSIONAL ENGINEER TO DESIGN THE SHORING AND <br />SPECIFY DEMOLITION PROCEDURES. <br />IT IS THE CONTRACTOR'S RESPONSIBILITY FOR MEANS AND <br />METHODS OF DEMOLITION AND NEW CONSTRUCTION. PRIOR TO <br />THE EXCAVATION OF FOUNDATIONS ADJACENT TO THE EXISTING <br />STRUCTURE, PROVIDE ADEQUATE SUPPORT FOR THE SUB -BASE <br />TO PREVENT UNDERMINING. <br />DURING DEMOLITION AND RECONSTRUCTION, THE CONTRACTOR <br />SHALL COORDINATE WITH THE OWNER'S MECHANICAL <br />CONSTRUCTION MANAGER ANY REQUIRED SAFETY BARRIERS <br />OR BARRICADES AND DUST WALLS. REFER TO THE OWNER'S <br />MECHANICAL CONSTRUCTION MANAGER FOR PHASING AND <br />SCHEDULING DEMOLITION AND NEW CONSTRUCTION. <br />DISPOSAL OF ALL DECOMMISSIONED EQUIPMENT, NOT <br />APPORTIONED TO OWNER'S DESIGNATED SALVAGE VENDOR, <br />SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR IN <br />ACCORDANCE WITH LOCAL CODES AND ANY GOVERNMENTAL <br />REGULATIONS: REFER TO OWNER DIRECTIVES AND <br />SPECIFICATIONS. THE CONTRACTOR SHALL COORDINATE THE <br />PICK-UP DATE WITH THE DESIGNATED SALVAGE VENDOR, <br />PREPARE AND LOAD THE DESIGNATED SALVAGE ITEMS, <br />KEEPING THEM INTACT AND IN ACCORDANCE WITH LOCAL <br />CODES AND ANY GOVERNMENTAL REGULATIONS- REFER TO <br />OWNER DIRECTIVES AND SPECIFICATIONS. ITEMS TO BE <br />SALVAGED BY OWNER'S DESIGNATED SALVAGE VENDOR SHALL <br />BE LIMITED TO: VARIABLE FREQUENCY DRIVES, CONDENSING <br />UNITS, CONDENSERS, EVAPORATORS, COPPER PIPING, ROOF <br />TOP UNITS, AIR HANDLING UNITS, AND COMPRESSOR HOUSES. <br />REFER TO SPECIFICATION SECTION 1500 FOR ADDITIONAL <br />INFORMATION REGARDING STORMWATER RUNOFF CONTROL. <br />CONDUCT ALL DEMOLITION AND REMOVAL OF DEBRIS AS <br />REQUIRED TO ENSURE MINIMUM INTERFERENCE WITH <br />BUILDING/SITE FACILITIES AND OPERATIONS. <br />NOTES INDICATING DEMOLITION WORK ARE NOT CONFINED <br />SOLELY TO THE DEMOLITION PLANS. THE CONTRACTOR SHALL <br />REVIEW ALL CONSTRUCTION DOCUMENTS, INCLUSIVE OF <br />SCHEDULES AND SPECIFICATIONS, TO DETERMINE FULL EXTENT <br />OF DEMOLITION WORK. <br />DEMOLITION NOTES <br />1. REMOVAL OF ANY SALVAGE EQUIPMENT OR DEBRIS IS <br />- <br />PROHIBITED. THIS INCLUDES THE SALE OF COPPER, ALUMINUM, <br />OR ANY RELATED MATERIALS. <br />2. WHERE APPLICABLE COOLER PANEL MANUFACTURER SHALL <br />DEMOLISH AND PROMPTLY HAUL OFF WALK-IN PANELS AND <br />DOORS TO BE REPLACED. <br />3. DURING DEMOLITION AND RECONSTRUCTION PHASES, <br />COORDINATE LOCATION OF ALL DUST WALLS AND SECURITY <br />om <br />ENCLOSURES WITH STORE MANAGER. REFER TO DUST WALL <br />DETAIL. <br />4. ALL NEW EQUIPMENT MUST BE ON SITE PRIOR TO STARTING ANY <br />DEMOLITION OR CONSTRUCTION. <br />5. PATCH/REPAIR FLOOR COVERING AS REQUIRED AFTER <br />INSTALLATION OF NEW CASES. MATCH EXISTING FLOORING <br />TYPE, COLOR, PATTERN, AND FINISH. <br />CONSTRUCTION LEGEND <br />EXISTING TO REMAIN <br />_ DEMOLISHED <br />AREA TO BE DEMOLISHED <br />UF:I0"AD] <br />0 <br />Cn <br />O 0- zjw WZOZI <br />LL <br />Z) <br />w <br />lmlow2zllo3ZDI <br />p OW <br />L <br />0,wpaz�rz <br />T <br />QF- F�--LLOtpf1W OU <br />O <br />E <- O� <br />LL¢ �Htw <br />w <br />n UFO 1 <br />�¢zc)<00 <br />�LLLL-NW,o,,oz o�p <br />O <br />I- <br />O W n Z M w W ¢ W O O O¢ <br />g <br />Zl,o�°wt9ZTTFZ, <br />¢¢= a Z W H p W W pw o O E? <br />a_ <br />ao=wom¢w=a_x�owc� <br />P: <br />(n <br />DwazI ~_t: 7Wa�Hw <br />I--DN <br />UC)COaOww <br />O <br />m <br />O <br />00 J <br />CO CO LjL n <br />p O <br />J o <br />o <br />~ N <br />O C) <br />0 <br />Z o <br />w O <br />0 <br />0 N <br />O N <br />0 W <br />W <br />N w co <br />D <br />z <br />m <br />O <br />ISSUE BLOCK <br />CHECKED BY: JPUJDS <br />DRAWN BY: AMU <br />DOCUMENT DATE: 06/30/23 <br />THIS ITEM HAS BEEN <br />ELECTRONICALLY SIGNED <br />AND SEALED BY MICHAEL <br />DEAN SCHAEFER ON THE <br />DATE LISTED BELOW <br />USING A DIGITAL <br />SIGNATURE. <br />PRINTED COPIES OF THIS <br />DOCUMENT ARE NOT <br />CONSIDERED SIGNED AND <br />SEALED AND THE <br />SIGNATURE MUST BE <br />VERIFIED ON ANY <br />ELECTRONIC COPIES. <br />MICHAEL D. SCHAEFER <br />LICENSE # 89591 <br />D. <br />Mo. 89591 ; �j <br />y' <br />i.•. STATE OF <br />��j �'iORiP�`.•'•• • �� <br />9i/;l i llvlol <br />06/30/2023 <br />DEMOLITION <br />PLAN <br />2 <br />EXISTING CONDITIONS WERE TAKEN FROM <br />ORIGINAL DRAWINGS AND MAY NOT REFLECT <br />EXACT "AS -BUILT" CONDITIONS. CONTRACTOR <br />SHALL FIELD VERIFY ALL EXISTING CONDITIONS <br />PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR <br />SHALL CAREFULLY COORDINATE NEW WORK AND <br />DEMOLITION WITH ALL OTHER DISCIPLINES AND <br />EXISTING CONDITIONS. <br />EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING <br />A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br />SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE <br />TO ACQUAINT THEMSELF WITH THIS KNOWLEDGE DOES <br />NOT RELIEVE THE RESPONSIBILITY OF PERFORMING <br />THE WORK PROPERLY. NO ADDITIONAL <br />COMPENSATION SHALL BE ALLOWED BECAUSE OF <br />CONDITIONS THAT OCCUR DUE TO FAILURE TO <br />FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. <br />SHEET: <br />Dl <br />