ABBREVIATIONS <br />GENERAL NOTES <br />SPECIAL INSPECTIONS REQUIRED <br />LI�9L�3i[S�7_1�I-� <br />AB ANCHOR BOLT <br />ACI AMERICAN CONCRETE INSTITUTE <br />AFF ABOVE FINISHED FLOOR <br />AHU AIR HANDLING UNIT <br />AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION <br />AISI AMERICAN IRON AND STEEL INSTITUTE <br />ARCH ARCHITECTURAL <br />ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS <br />AWS AMERICAN WELDING SOCIETY <br />BFF BELOW FINISHED FLOOR <br />BL BLOCK LINTEL <br />BM BEAM <br />BO BOTTOM OF <br />BOM BOTTOM OF MASONRY <br />BOS BOTTOM OF STEEL <br />BRG BEARING <br />CJ CONTRACTION JOINT <br />CL CENTER LINE <br />CLR CLEAR <br />CMU CONCRETE MASONRY UNIT <br />COL COLUMN <br />CONC CONCRETE <br />COND CONDENSER UNIT <br />CONST CONSTRUCTION <br />CONT CONTINUOUS <br />DIA DIAMETER <br />EC EVAPORATIVE COOLER <br />EF EXHAUST FAN <br />EIFS EXTERIOR INSULATION AND FINISH SYSTEM <br />EJ EXPANSION JOINT <br />EL ELEVATION <br />ELEC ELECTRICAL <br />EQ EQUAL <br />ETR EXISTING TO REMAIN <br />EW EACH WAY <br />EXIST EXISTING <br />FDN FOUNDATION <br />FF FINISHED FLOOR <br />FS FAR SIDE <br />FTG FOOTING <br />FV FIELD VERIFY <br />GA GAUGE <br />GC GENERAL CONTRACTOR <br />H HEIGHT <br />HORIZ HORIZONTAL <br />HSA HEADED STUD ANCHOR <br />HSS HOLLOW STRUCTURAL SHAPE <br />INFO INFORMATION <br />ISO ISOLATION <br />JBE JOIST BEARING ELEVATION <br />JST JOIST <br />JT JOINT <br />KSI KIPS PER SQUARE INCH <br />L LENGTH <br />LB POUNDS <br />LLH LONG LEG HORIZONTAL <br />LLV LONG LEG VERTICAL <br />LONG LONGITUDINAL <br />MAX MAXIMUM <br />MECH MECHANICAL <br />MFR MANUFACTURER <br />MIN MINIMUM <br />MISC MISCELLANOUS <br />MO MASONRY OPENING <br />MTL METAL <br />NIC NOT IN CONTRACT <br />NO NUMBER <br />NS NEAR SIDE <br />NTS NOT TO SCALE <br />OC ON CENTER <br />OD OUTSIDE DIAMETER <br />OH OPPOSITE HAND <br />PAF POWER ACTUATED FASTENER <br />PCF POUNDS PER CUBIC FOOT <br />PL PLATE <br />PLF POUNDS PER LINEAR FOOT <br />PLUMB PLUMBING <br />PMEJ PREMOLDED EXPANSION JOINT <br />PSF POUNDS PER SQUARE FOOT <br />PSI POUNDS PER SQUARE INCH <br />QTY QUANITY <br />RACK REFRIGERATION RACK <br />REF REFER TO <br />REINF REINFORCING <br />REQD REQUIRED <br />REV REVERSE <br />RO ROUGH OPENING <br />RTU ROOF TOP UNIT <br />SCHED SCHEDULE <br />SDI STEEL DECK INSTITUTE <br />SIM SIMILAR <br />SJI STEEL JOIST INSTITUTE <br />SPCS SPACES <br />SPECS SPECIFICATIONS <br />STRUC STRUCTURAL <br />T&B TOP AND BOTTOM <br />THK THICKNESS <br />TO TOP OF <br />TOC TOP OF CONCRETE <br />TOF TOP OF FOOTING <br />TOM TOP OF MASONRY <br />TOS TOP OF STEEL <br />TOW TOP OF WALL <br />TRANS TRANSVERSE <br />TYP TYPICAL <br />UNO UNLESS NOTED OTHERWISE <br />VERT VERTICAL <br />W WIDTH <br />WP WORK POINT <br />GENERAL <br />1. FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY TO COMPLETE THE WORK SHOWN OR IMPLIED BY THESE DRAWINGS. SHOP DRAWINGS SHALL BE SUBMITTED TO <br />THE ENGINEER FOR REVIEW AND APPROVAL PRIOR TO COMMENCING WORK. <br />2. EXISTING CONDITIONS SHOWN MAY NOT REFLECT EXACT "AS -BUILT" CONDITIONS. BIDDERS SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BID. WITHIN <br />ONE WEEK FROM THE START OF CONSTRUCTION DATE GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING MATERIAL, MEASUREMENTS, AND ELEVATIONS AND SHALL <br />NOTIFY THE STRUCTURAL ENGINEER OF RECORD AND THE OWNER'S CONSTRUCTION MANAGER OF ANY DISCREPANCIES OR FORESEEN PROBLEMS. GENERAL CONTRACTOR <br />SHALL BE RESPONSIBLE FOR COORDINATING ALL FIELD MEASUREMENTS, EXISTING CONDITIONS, AND KNOWN COMPLICATIONS WITH THE MATERIAL SUPPLIERS. <br />3. GENERAL CONTRACTOR SHALL CAREFULLY COORDINATE DEMOLITION AND NEW CONSTRUCTION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS. <br />4. GENERAL CONTRACTOR SHALL PROTECT EXISTING STRUCTURES, UTILITIES, PROPERTY, ETC DURING CONSTRUCTION. RESTORE ALL ITEMS DAMAGED, AS REQUIRED BY <br />OWNER'S REPRESENTATIVE, TO THE OWNER'S SATISFACTION AT NO COST TO OWNER OR WITHOUT EXTENSION OF CONTRACT TIME. <br />5. BUILDING COMPONENTS ABANDONED BY THE SCOPE OF WORK SHALL BE SECURED TO PREVENT FALLING, LOOSENING OR CREATING DAMAGE OF ANY KIND IN THE FUTURE. <br />6. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY SUPPORT AND MAINTAINING STABLITY OF EXISTING STRUCTURE DURING ALL PHASES OF CONSTRUCTION. <br />7. GENERAL CONTRACTOR SHALL PROVIDE FIRE PROTECTION FOR THE EXISTING STRUCTURE AND BUILDING CONTENTS DURING WELDING OR ANY OTHER CONSTRUCTION <br />ACTIVITY THAT GENERATES SPARKS OR INTENSE HEAT. <br />8. GENERAL CONTRACTOR SHALL COORDINATE THE SIZE AND LOCATION OF PENETRATIONS THROUGH THE STRUCTURE FOR MECHANICAL, ELECTRICAL AND PLUMBING WORK. <br />9. THE STRUCTURAL ENGINEER OF RECORD, ITS EMPLOYEES, AND REPRESENTATIVES SHALL NOT BE RESPONSIBLE FOR, AND WILL NOT HAVE CONTROL OF, CONSTRUCTION <br />MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE CONSTRUCTION WORK; NOR WILL <br />THEY BE RESPONSIBLE FOR ANY FAILURE BY THE CONTRACTOR TO PERFORM OR COMPLETE CONSTRUCTION IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. <br />STRUCTURAL STEEL <br />1. STRUCTURAL STEEL SHALL MEET THE FOLLOWING MINIMUM YIELD STRENGTH AND SPECIFICATIONS. FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE LATEST <br />EDITION OF THE "AISC CODE OF STANDARD PRACTICE". <br />STRUCTURAL STEEL YIELD ASTM SPECIFICATION <br />A. PLATES & ANGLES: 36 KSI A 36, UNO <br />O COAT O INHIBITOR PRIMER PAINT CONFORMING TO THE SPECIFICATIONS. FIELD TOUCH UP ALL UNPAINTED NICKED AND <br />2. ALL STRUCTURAL STEEL SHALL HAVE ONE SHOP F RUST O , <br />WELDED AREAS. PAINT ALL STEEL EXPOSED TO VIEW TO MATCH EXISTING. <br />3. WELDING SHALL MEET ANSI/AWS D1.1 STRUCTURAL WELDING CODE. ELECTRODES SHALL BE 70 KSI LOW HYDROGEN. ALL WELDING SHALL BE PERFORMED BY CERTIFIED <br />WELDERS. <br />STEEL JOISTS AND JOIST GIRDERS <br />1. EXISTING STEEL JOISTS AND JOIST GIRDERS ARE ASSUMED TO BE IN GOOD CONDITION AND IN COMPLIANCE WITH THE STEEL JOIST INSTITUTE SPECIFICATIONS. ANY DAMAGE <br />TO EXISTING JOISTS OR GIRDERS SHALL BE REPORTED PRIOR TO ADDING LOAD TO FRAMING. <br />2. PRIOR TO STARTING ANY WORK OR ADDING ANY ADDITIONAL LOADS TO THE ROOF STRUCTURE, CONTACTOR SHALL VISUALLY OBSERVE JOISTS AND JOIST GIRDERS FOR SIGNS <br />OF DAMAGE OR DISTRESS, INCLUDING BUT NOT LIMITED TO, BENT WEB AND/OR CHORD MEMBERS, CRACKED WELDS, MISSING WELDS, ETC. ANY DAMAGE TO EXISTING JOISTS <br />OR JOIST GIRDERS SHALL BE REPORTED TO THE FOR PRIOR TO REINFORCING OR ADDING LOAD TO THE ROOF STRUCTURE. <br />3. NO WORK SHALL BE PERFORMED ON ANY EXISTING JOIST AND/OR JOIST GIRDER IDENTIFIED BY THE GENERAL CONTRACTOR TO BE DAMAGED OR DISTRESSES UNTIL SUCH TIME <br />AS THE FOR HAS PROVIDED WRITTEN INSTRUCTION TO DO SO. <br />4. ALL PAINT AND DEBRIS SHALL BE CLEANED FROM STUCTURAL MEMBER PRIOR TO WELDING. <br />5. HANGERS SUPPORTING MECHANICAL EQUIPMENT FROM JOIST CHORDS SHALL BE LOCATED WITHIN 3 INCHES OF JOIST PANEL POINTS OR JOIST SHALL BE REINFORCED PER <br />JOIST REINFORCING DETAIL. HANGER LOADS GREATER THAN 100 POUNDS SHALL NOT BE ATTACHED TO THE EDGE OF CHORD ANGLES AND SHALL BE CENTERED ON JOIST <br />CHORD. <br />6. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF EXISTING BUILDING ELEMENTS THAT PREVENT ACCESS TO INSTALL JOIST REINFORCEMENT, <br />INCLUDING BUT NOT LIMITED TO SUSPENDED CEILINGS, DUCTWORK, RTU PLENUMS, CABLES, LARGE PIPING, ETC. <br />7. JOIST WEB CONFIGURATION IS SHOWN FOR REFERENCE ONLY, FIELD VERIFY ACTUAL CONFIGURATION AND WEB TYPE. <br />8. ALL JOIST REINFORCEMENT SHALL BE INSTALLED AND INSPECTED BEFORE APPLYING NEW LOADS. I.E. RTU'S, AHU'S, COOLING TOWERS, AND ROOF SUPPORTED ITEMS. <br />9. PRIOR TO INSTALLATION OF JOIST REINFORCEMENT, CONTRACTOR SHALL REMOVE ALL LIVE LOADS FROM JOISTS TO BE REINFORCED. THIS INCLUDES BUT IS NOT LIMITED TO <br />PONDED WATER, ICE, SNOW (REMOVE SNOW TO EXPOSE ROOF MATERIAL), STAGED CONSTRUCTION MATERIALS / EQUIPMENT, ETC. <br />10. INSTALL WEB REINFORCING PRIOR TO CHORD REINFORCING. COPE OUTSTANDING LEG OF WEB REINFORCING AS REQUIRED FOR PLACEMENT OF CHORD REINFORCING. <br />11. IF EXISTING JOIST BRIDGING INTERFERES WITH INSTALLATION OF REINFORCING, REMOVE BRIDGING AND REPLACE IMMEDIATELY UPON COMPLETION OF REINFORCING <br />INSTALLATION. IF BRIDGING TABS FOR BOLTED BRIDGING INTERFERE WITH INSTALLATION OF REINFORCING, REMOVE TABS AND REPLACE IMMEDIATELY UPON COMPLETION OF <br />REINFORCING INSTALLATION. NEW CONNECTIONS SHALL MATCH EXISTING. <br />12. STEEL ERECTOR SHALL FIELD CUT REINFORCING TO FIT FROM STOCK LENGTHS. <br />SPECIAL INSPECTIONS AS REQUIRED <br />BY THE ENGINEER OF RECORD <br />PERIODIC SPECIAL INSPECTIONS: <br />1. WELDING - REFER TO APPENDIX B OF THE SPECIFICATION. <br />2. JOIST REINFORCING - THE CTL SHALL INSPECT THE FINAL PLACEMENT AND <br />WELDS OF ALL NEW REINFORCEMENT. UPON COMPLETION OF THE <br />INSPECTIONS, THE CTL WILL SUBMIT THEIR REPORT TO JBA FOR FINAL <br />APPROVAL. <br />CERTIFIED TESTING LAB (CTL): <br />THIS PROJECT REQUIRES SPECIAL INSPECTIONS THAT ARE TO BE PERFORMED BY <br />THE APPROVED CERTIFIED TESTING LAB (CTL). UPON RECEIVING THE AWARD <br />NOTICE ISSUED BY OWNER, THE CONTRACTOR SHALL CONTACT THE APPROVED <br />CTL AND JOHNSTON BURKHOLDER ASSOCIATES (JBA) TO PROVIDE A <br />CONSTRUCTION SCHEDULE FOR WORK REQUIRING SPECIAL INSPECTIONS. CTL <br />AND JBA CONTACT INFORMATION IS PROVIDED BELOW. THE CTL SHALL BE <br />RESPONSIBLE FOR COORDINATING THE SPECIAL INSPECTIONS AND COMPLETING <br />INSPECTION REPORTS. THE CTL SHALL SEND COMPLETED REPORTS, A LIST OF <br />DEVIATIONS AND SUPPORT DOCUMENTATION TO JBA IN A TIMELY MANNER. JBA <br />WILL REVIEW INSPECTION REPORTS AND RESPOND TO DEVIATIONS AS REQUIRED. <br />TESTING LAB SHALL SEND OBSERVATION/TEST REPORTS TO: <br />JOHNSTON BURKHOLDER ASSOCIATES <br />ATTN: TREVOR WRIGHT (jba-hei@jbaengr.com) <br />TESTING LAB SHALL SEND BILLING INVOICE TO: <br />EVOCO FUZE SYSTEM (OR AS DIRECTED BY <br />OWNER'S MECHANICAL CONSTRUCTION MANAGER) <br />CTL CONTACT INFORMATION: <br />COMPANY: <br />ECS MID -ATLANTIC <br />CONTACT: <br />MICHAEL GALLI <br />PHONE: <br />(757) 229-6677 <br />EMAIL: <br />mgalli@ecslimited.com <br />FIELD VERIFY GAP DISTANCE BETWEEN <br />ANGLES; WELD PLATE THICKNESS JOIST TOP <br />SHALL BE 1/8" THINNER (OR LESS) CHORD <br />THAN GAP DISTANCE - <br />z� 1/8 <br />1/8 <br />CURB <br />CL <br />PANEL <br />POINT <br />1 1/2" <br />MAX_ `I,... <br />JOIST BOTTOM <br />CHORD <br />u PLATE <br />SECTION A <br />1. BUILDING CODE <br />A. BUILDING CODE 2020 FLORIDA BUILDING CODE <br />2. GRAVITY LOADS <br />A. ROOF DEAD LOAD 12 PSF (PER ORIGINAL <br />DRAWINGS) <br />B. ROOF LIVE LOAD 20 PSF (MIN OR SNOW LOAD) <br />C. ROOF SNOW LOADS <br />1. GROUND SNOW LOAD (Pg) <br />0 PSF <br />3. LATERAL LOADS <br />A. WIND LOADS <br />1. BASIC WIND SPEED (3-SECOND GUST) <br />- ULTIMATE DESIGN WIND SPEED <br />138 MPH <br />2. WIND EXPOSURE CATEGORY <br />C <br />3. RISK CATEGORY <br />II <br />B. SEISMIC LOADS (SERVICE) <br />1. 5% DAMPED MAPPED ACCELERATION PARAMETER (Ss) <br />0.058 <br />2. 1-SEC PERIOD MAPPED ACCELERATION PARAMETER (S1) 0.032 <br />3. 5% DAMPED SPECTRAL RESPONSE COEFF. (Sds) <br />0.062 <br />4. 1-SEC PERIOD SPECTRAL RESPONSE COEFF. (Sd1) <br />0.051 <br />5. SITE CLASS <br />D (DEFAULT) <br />6. RISK CATEGORY <br />11 <br />7. IMPORTANCE FACTOR (le) <br />1.0 <br />8. SEISMIC DESIGN CATEGORY <br />A <br />JOIST TOP <br />CHORD <br />I <br />1-6 /WELD 2" <br />1-6\EA END TYP, WELD <br />1/8 1-6 2" EA END <br />SECTION B <br />TYP, WELD <br />2" EA END <br />SECTION C <br />P, WELD <br />EA END <br />CL CL <br />CL PANEL PANEL <br />PANEL POINT CURB POINT CURB <br />POINT 3" TYP <br />B TOP CHORD 3" TYPV <br />C <br />1 1/2" EA END PANEL POINT EA EN <br />MAX TOP CHORD TOP CHORD <br />PANEL POINT PANEL POINT <br />� ! JOIST TOP <br />CHORD <br />- - - - - - - L 1 ---- ---- ---- <br />BOTTOM CHORD <br />PANEL POINT <br />PROVIDE 7/8-(FIELD VERIFY) x 2" CONT PLATE BETWEEN <br />TOP CHORD ANGLES AT LOCATIONS WHERE REINFORCING <br />PER 2-S1 IS REQUIRED BUT CANNOT BE INSTALLED TO DUE <br />TO AN EXISTING OBSTRUCTION; PLATE SHALL BE <br />INSTALLED PRIOR TO INSTALLATION OF NEW UNIT <br />OPTION 1 <br />JOIST BOTTOM <br />CHORD <br />GIST TOP <br />:HORD <br />JOIST BOTTOM <br />PANEL POINT <br />PROVIDE L1x1x3/16 EA SIDE OF JOIST TOP CHORD AT <br />LOCATIONS WHERE REINFORCING PER 2-S1 IS <br />REQURIED BUT CANNOT BE INSTALLED TO DUE TO AN <br />EXISTING OBSTRUCTION; ANGLES SHALL BE <br />INSTALLED PRIOR TO INSTALLATION OF NEW UNIT <br />Kai 01 ] <br />ALTERNATE JOIST REINFORCING AT CONCENTRATED LOADS <br />3/4" = 1'-0" <br />TOP CHORD PANEL <br />3" OR <br />CONCENTRATED <br />LOAD, REF NOTE <br />if <br />\ <br />GENERAL CONTRACTOR TO PROVIDE AND INSTALL <br />FIELD STRUT (Laa3/16) EACH SIDE OF JOIST AT ALL <br />LOCATIONS WHERE CONCENTRATED LOAD DOES <br />NOT OCCUR WITHIN 3" OF A PANEL POINT. INSTALL <br />ANGLE WITH ONE END AT LOCATION OF LOAD AND <br />OTHER END AT A PANEL POINT ON THE OPPOSITE <br />CHORD, TYP. ANGLES SHALL BE INSTALLED PRIOR <br />TO NEW LOAD BEING APPLIED TO THE JOIST <br />> <br />1/8 1 TYP EACH <br />1/8 1 END EACH <br />ANGLE <br />NOTE: <br />PROVIDE JOIST REINF IN ACCORDANCE WITH THIS DETAIL <br />FOR ALL CONCENTRATED LOADS IN EXCESS OF 100 LBS. <br />WHERE MORE THAN ONE CONCENTRATED LOAD EXISTS <br />WITHIN A CHORD PANEL AND THE SUM OF THOSE LOADS <br />EXCEEDS 100 LBS, PROVIDE JOIST REINFORCEMENT AS <br />DETAILED SUCH THAT THE SUM OF THE LOADS WITHIN <br />THE REMAINING UNSUPPORTED CHORD LENGTH DOES <br />NOT EXCEED 100 LBS. <br />r, <br />CONCENTRATED <br />LOAD, REF NOTE <br />3" OR <br />GREATER <br />BOTTOM CHORD PANEL <br />JOIST TOP <br />CHORD <br />JOIST BOTTOM <br />CHORD <br />JOIST TOP <br />CHORD <br />JOIST BOTTOM <br />PANEL POINT <br />JOIST BOTTOM <br />CHORD PROVIDE L1x1x3/16 EA SIDE OF JOIST TOP CHORD AT <br />LOCATIONS WHERE REINFORCING PER 2-S1 IS <br />REQUIRED BUT CANNOT BE INSTALLED TO DUE TO <br />AN EXISTING OBSTRUCTION; ANGLES SHALL BE <br />INSTALLED PRIOR TO INSTALLATION OF NEW UNIT <br />OPTION 3 <br />NOTE: <br />CONTRACTOR SHALL <br />VERIFY THAT EXISTING <br />REF MECH I CURB IS LEVEL PRIOR TO <br />FOR RTU INSTALLING NEW UNIT. <br />u <br />HOLD DOWN BRACKET; <br />REF MECH FOR SIZE, <br />LOCATION AND <br />ATTACHMENT; PROVIDE <br />A MINIMUM OF 6 HOLD <br />DOWNS PER RTU <br />REF SUPPLIER FOR CURB <br />ADAPTER TO EXISTING CURB <br />CONNECTION; PROVIDE MIN <br />CONN OF 1/4-14 x 4" ZINC -PLATED <br />SELF -DRILLING SCREW WITH <br />BONDED SEALING WASHER; <br />LOCATE IN PRE -DRILLED HOLES <br />NEW OR EXISTING <br />CURB ADAPTER <br />EXISTING CURB <br />1/8 1 TYP EACH <br />1/8 1 END EACH <br />ANGLE <br />NOTE: <br />PROVIDE JOIST REINF IN ACCORDANCE WITH THIS DETAIL <br />FOR ALL CONCENTRATED LOADS IN EXCESS OF 100 LBS. <br />WHERE MORE THAN ONE CONCENTRATED LOAD EXISTS <br />WITHIN A CHORD PANEL AND THE SUM OF THOSE LOADS <br />EXCEEDS 100 LBS, PROVIDE JOIST REINFORCEMENT AS <br />DETAILED SUCH THAT THE SUM OF THE LOADS WITHIN <br />THE REMAINING UNSUPPORTED CHORD LENGTH DOES <br />NOT EXCEED 100 LBS. <br />r, <br />CONCENTRATED <br />LOAD, REF NOTE <br />3" OR <br />GREATER <br />BOTTOM CHORD PANEL <br />JOIST TOP <br />CHORD <br />JOIST BOTTOM <br />CHORD <br />JOIST TOP <br />CHORD <br />JOIST BOTTOM <br />PANEL POINT <br />JOIST BOTTOM <br />CHORD PROVIDE L1x1x3/16 EA SIDE OF JOIST TOP CHORD AT <br />LOCATIONS WHERE REINFORCING PER 2-S1 IS <br />REQUIRED BUT CANNOT BE INSTALLED TO DUE TO <br />AN EXISTING OBSTRUCTION; ANGLES SHALL BE <br />INSTALLED PRIOR TO INSTALLATION OF NEW UNIT <br />OPTION 3 <br />NOTE: <br />CONTRACTOR SHALL <br />VERIFY THAT EXISTING <br />REF MECH I CURB IS LEVEL PRIOR TO <br />FOR RTU INSTALLING NEW UNIT. <br />u <br />HOLD DOWN BRACKET; <br />REF MECH FOR SIZE, <br />LOCATION AND <br />ATTACHMENT; PROVIDE <br />A MINIMUM OF 6 HOLD <br />DOWNS PER RTU <br />REF SUPPLIER FOR CURB <br />ADAPTER TO EXISTING CURB <br />CONNECTION; PROVIDE MIN <br />CONN OF 1/4-14 x 4" ZINC -PLATED <br />SELF -DRILLING SCREW WITH <br />BONDED SEALING WASHER; <br />LOCATE IN PRE -DRILLED HOLES <br />NEW OR EXISTING <br />CURB ADAPTER <br />EXISTING CURB <br />W. c-'W mw-m �! d' OO <br />0) <br />W <br />O�ynU ~� C7z <br />pit.2nW- Ww iz. <br />w <br />wz <br />%HzapW3C_wiwo9w0 <br />Of <br />O <br />0- Z- waaw <br />UcoFo-T <br />z <br />a<')mo: <br />rn �ZZwwwwwz Wa <br />aly m-OOwO2p <br />O <br />65-Z <br />z� w as zo <br />�UUwctpTMofzd <br />g <br />3WPIZg-o�°w�Z <br />D <br />ov°iw0��3z>ioyg <br />m <br />�,a� a a <br />1-oc°092o0o n�dTow:<F <br />2 <br />W cn ; <br />o <br />q <br />U- <br />O,, <br />vQj � <br />y <br />C <br />8 <br />co <br />z0 <br />yC <br />� j oo <br />o0 <br />�o <br />U <br />O <br />m <br />2 <br />O <br />00li <br />© cp u <br />0 0 <br />`) O <br />j,0 <br />t6 CL <br />O a <br />O � <br />O � <br />n/ Z o <br />M <br />N <br />-Gig <br />W <br />N w <br />m <br />D <br />z <br />m <br />O <br />ISSUE BLOCK <br />CHECKED BY: JSH <br />DRAWN BY: BWM <br />DOCUMENT DATE: 06/30/23 <br />[JBA PROJECT NO: 2301500706 <br />h No. <br />&mow <br />A.° <br />6/29/23 <br />ENGINEER OF RECORD: <br />BENJAMIN B. BAILEY, P.E. <br />930 CENTRAL STREET <br />KANSAS CITY, MO 64105 <br />FLORIDA LICENSE #88408 <br />GENERAL <br />NOTES AND <br />EQUIPMENT <br />REPLACEMENT <br />DETAILS <br />STANDARD JOIST REINFORCING <br />AT CONCENTRATED LOAD <br />3/4" = 1'-0" 5.0-2 <br />RTU TO CURB ADAPTER ATTACHMENT <br />NTS 6.0-4 <br />SHEET: <br />s 1 <br />