EQUIPMENT SCHEDULE
<br />CONTRACTOR IS RESPONSIBLE, UPON AWARD, TO CONTACT AND VERIFY ALL DELIVERY DATES/TIMES WITH EVERY VENDOR LISTED BELOW. THIS IS UNIQUE TO
<br />CAPITAL EXPENDITURES PROJECTS. DATE CHANGE REQUESTS MUST BE SENT TO BOTH
<br />sharon.ha jdauftal—mart.00m AND
<br />duane.davieftal—mart.00m
<br />MARK
<br />DESCRIPTION
<br />MANUFACTURER
<br />MODEL #
<br />SUPPLIED
<br />INSTALLED
<br />FINAL
<br />BY
<br />BY
<br />CONNECT
<br />R214
<br />M/D PRODUCE (EXTENDED KICKPLATE)
<br />KYSOR WARREN
<br />DX6LN
<br />WM
<br />C
<br />C
<br />P007C
<br />PRODUCE MISTING SYSTEM(AL,AR,AZ,CA,CO,CT,FL,GA,KS,KY,LA,MS,MT,NC,ND,NE,NM,NV,
<br />PRODEW
<br />-
<br />WM
<br />C
<br />C
<br />OK, PA, SC, SD, TN, TX, U T, VA, WV, WY)
<br />—
<br />REFRIGERATED SYSTEMS
<br />IHILL PHOENIX
<br />—
<br />WM
<br />C
<br />C
<br />—
<br />INOVAR EQUIPMENT
<br />INOVAR
<br />—
<br />WM
<br />4—C
<br />C
<br />C
<br />—
<br />IPRODUCE SHELVES
<br />IMARCO
<br />—
<br />WM
<br />C
<br />ABBREVIATION KEY
<br />C — CONTRACTOR
<br />WM — WAL—MART
<br />V — VENDOR
<br />VER 6.2.05
<br />0
<br />C.7
<br />------- ----- --
<br />ROOF DECK
<br />DO NOT USE DUSTWALL
<br />CONTINUE PLYWOOD TO SHORE ROOF JOISTS
<br />TO DECK
<br />WALL TO
<br />BE REMOVED
<br />SALES
<br />1 /2" CD PLYWOOD 6'-0" LOAD BEARING
<br />4x8x8'—O" HORIZONTAL, 4'-0" ELSEWHERE
<br />PROVIDE 2X4 NAILER 0
<br />ALL JOINTS
<br />INSTALL CONTINUOUS
<br />LAYER 6 MIL. POLY
<br />SHEETS. TAPE ALL
<br />JI JI LIYI, 1\LI I LVIYI UIIYV -
<br />CONTRACTOR SHALL FURNISH AND
<br />INSTALL STAINLESS STEEL TRIM TO
<br />CLOSE ANY GAPS THAT ARE LEFT
<br />BETWEEN THE END CASES AND
<br />LONG CASE RUNS AFTER THE CASES
<br />CASES FURNISHED BY WALMART, INSTALLED
<br />BY CONTRACTOR. ALL NEW EQUIPMENT MUST ALL EXISTING REFRIGERATED
<br />BE ON SITE PRIOR TO STARTING ANY CASES ARE TO REMAIN
<br />ARE SET IN THEIR FINAL POSITION. DEMOLITION OR CONSTRUCTION. UNLESS OTHERWISE NOTED
<br />O
<br />a2FIXTURE PLAN -
<br />SCALE: 1 /8" = 1'-0"
<br />JOINTS
<br />NOTES:
<br />i
<br />I I
<br />1.
<br />INSTALL TEMPORARY WALL IN
<br />—
<br />FOR WALLS UP TO
<br />SECTIONS APPROXIMATELY
<br />REACH
<br />14'-0", USE 4" 22
<br />��
<br />40 —0 PER DAY
<br />EXISTING
<br />COFFIN
<br />EXISTING —IN
<br />CASES TO REMAIN
<br />GAUGE METAL
<br />(COORDINATE W/STORE
<br />w. ,r..-....__....._; CASES
<br />TO REMAIN
<br />STUDS 24" O.C.
<br />MANAGER)
<br />OR 2X4 016" O.C;
<br />FOR WALLS HIGHER
<br />2.
<br />LOCATE VERTICAL STUDS AS
<br />„
<br />THAN 14 —0 USE6"
<br />NOT TO INTERFERE W/CEIL.
<br />_� E I
<br />I ; I
<br />20 GAUGE
<br />GRID OR LIGHT FIXTURES
<br />=----_ '
<br />=----_------_---—_----= j'T—
<br />— —
<br />METAL STUDS 0'f
<br />T---=---T
<br />24" O.C. OR 2X6
<br />3.
<br />LOCATE HORIZONTAL 2X4 ®
<br />r J
<br />016" O.C.
<br />2" ABOVE CEILING EXCEPT
<br />-'_-_—.____.----=="--_----------.-----=--...-
<br />------._.
<br />LIGHT FIXTURE LOCATIONS
<br />PAINT SALES SIDE
<br />OF WALL 0 FRONT
<br />4.
<br />SCREW PLYWOOD (MAXIMUM
<br />REMOVE EXISTING
<br />PRODUCE CASE
<br />REMOVE EXISTING M/D PRODUCE CASES TO BE REPLACED
<br />OF STORE, CASH
<br />SPACING: 12" O.C.)
<br />MISTING SYSTEM TO
<br />REGISTER & SNACK
<br />BE REPLACED
<br />BAR -
<br />SEALANT UNDER
<br />BOTTOM PLATE !
<br />CONTINUOUS SEALANT
<br />AGAINST PLATE
<br />3 4
<br />ANCHOR 0 24" O.C.
<br />3 DUST WALL
<br />NTS 09. ol. I
<br />DEMOLITION PLAN
<br />SCALE: 1 /8" = 1'—O"
<br />GENERAL NOTES
<br />1. DIMENSIONS OF REFRIGERATED CASES ARE TO THE
<br />OUTERMOST POINTS OF THE CASES; ENDCAPS AND
<br />BUMPERS ARE CONSIDERED PART OF THE CASE,
<br />WHERE THEY OCCUR. DIMENSIONS ON THE FIXTURE
<br />PLANS ARE FOR LAYOUT OF OWNER —FURNISHED ITEMS
<br />ONLY AND ARE NOT TO BE USED FOR LOCATION OF
<br />WALLS AND OTHER CONTRACTOR BUILT ITEMS.
<br />2. CONTRACTOR SHALL FURNISH AND INSTALL STAINLESS
<br />STEEL TRIM TO CLOSE ANY GAPS THAT ARE LEFT
<br />BETWEEN THE END CASES AND LONG CASE RUNS
<br />AFTER THE CASES ARE SET IN THEIR FINAL POSITION.
<br />3. CASES FURNISHED BY WALMART, INSTALLED BY
<br />CONTRACTOR. ALL NEW EQUIPMENT MUST BE ON SITE
<br />PRIOR TO STARTING ANY DEMOLITION OR
<br />CONSTRUCTION.
<br />4. WALK—IN COOLERS/FREEZERS FURNISHED AND
<br />INSTALLED BY COOLER PANEL MANUFACTURER. ALL
<br />NEW EQUIPMENT MUST BE ON SITE PRIOR TO
<br />STARTING ANY DEMOLITION OR CONSTRUCTION.
<br />5. CONTRACTOR SHALL BE RESPONSIBLE FOR
<br />MISCELLANEOUS WALK—IN COOLER/FREEZER WORK
<br />INCLUDING BUT NOT LIMITED TO EVAPORATORS,
<br />ELECTRICAL, EMS, SPRINKLER PENDANTS, CURBS,
<br />SANITARY COVE BASE, THRESHOLDS, FLOOR REPAIR
<br />AND RACKING.
<br />6. CONTRACTOR SHALL PAINT ALL NEW CONDUIT
<br />EXPOSED TO SALES FLOOR. MATCH CEILING OR
<br />ADJACENT WALL COLOR (WHERE APPLICABLE). CQNDUIT
<br />SHALL BE PAINTED PRIOR TO INSTALLATION.
<br />CONSTRUCTION LEGEND
<br />_v EXISTING TO REMAIN
<br />- - - DEMOLISHED
<br />AREA TO BE DEMOLISHED
<br />DEMOLITION REQUIREMENTS
<br />09.01.11
<br />1. ALL DEMOLITION SHALL BE CARRIED OUT IN A SAFE
<br />MANNER AND IN STRICT ACCORDANCE WITH OSHA
<br />REGULATIONS.
<br />2. THE CONTRACTOR SHALL FIELD VERIFY THE EXTENT OF
<br />DEMOLITION. THE WORK INCLUDES, BUT IS NOT LIMITED
<br />TO, THE DEMOLITION AND REMOVAL OF WALLS, DOORS,
<br />FLOORS, AND ELECTRICAL ITEMS INCLUDING CONDUITS AS
<br />SHOWN ON DRAWING OR AS REQUIRED FOR THE
<br />INSTALLATION OF NEW WORK FOR A COMPLETE JOB.
<br />3. WHEN UTILITIES ARE REMOVED, CAP AND SEAL A
<br />MINIMUM OF 8" BELOW FINISH FLOOR OR A MINIMUM OF
<br />6" ABOVE FINISHED CEILING. SHOW ALL ABANDONED AND
<br />CAPPED UTILITIES ON AS—BUILTS, DRAWINGS, AND
<br />RECORDED DOCUMENTS.
<br />4. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE
<br />ADEQUATE SHORING, BRACING, AND SUPPORT SYSTEMS
<br />AND TO KEEP THE EXISTING STRUCTURE INTACT AND IN
<br />A SAFE CONDITION DURING THE REMOVAL OF
<br />STRUCTURAL ITEMS AND NEW CONSTRUCTION.
<br />5. THE CONTRACTOR SHALL RETAIN A REGISTERED
<br />PROFESSIONAL ENGINEER TO DESIGN THE SHORING AND
<br />SPECIFY DEMOLITION PROCEDURES.
<br />6. IT IS THE CONTRACTOR'S RESPONSIBILITY FOR MEANS
<br />AND METHODS OF DEMOLITION AND NEW CONSTRUCTION.
<br />PRIOR TO THE EXCAVATION OF FOUNDATIONS ADJACENT
<br />TO THE EXISTING STRUCTURE, PROVIDE ADEQUATE
<br />SUPPORT FOR THE SUB —BASE TO PREVENT
<br />UNDERMINING.
<br />7. DURING DEMOLITION AND RECONSTRUCTION, THE
<br />CONTRACTOR SHALL COORDINATE WITH THE WALMART
<br />MECHANICAL SERVICES CONSTRUCTION MANAGER ANY
<br />REQUIRED SAFETY BARRIERS OR BARRICADES AND DUST
<br />WALLS. REFER TO THE WALMART MECHANICAL SERVICES
<br />CONSTRUCTION MANAGER FOR PHASING AND SCHEDULING
<br />DEMOLITION AND NEW CONSTRUCTION.
<br />8. IMMEDIATE SALVAGE/LEGAL DISPOSAL OF ALL
<br />DECOMMISSIONED EQUIPMENT SHALL BE THE
<br />RESPONSIBILITY OF THE CONTRACTOR. AT THE
<br />DISCRETION OF THE WALMART MECHANICAL SERVICES
<br />CONSTRUCTION MANAGER WALMART SHALL RETAIN THE
<br />OPTION TO OCCASIONALLY SALVAGE EMS EQUIPMENT,
<br />VARIABLE FREQUENCY DRIVE EQUIPMENT, COMPRESSORS,
<br />WALK—IN DOORS, EVAPORATORS, REFRIGERATED CASES,
<br />ETC. FROM REFRIGERATION EQUIPMENT TO BE REPLACED
<br />DURING THE CAP—X PROJECT. THE CONTRACTOR SHALL
<br />COORDINATE WITH THE WALMART MECHANICAL SERVICES
<br />CONSTRUCTION MANAGER ALL ITEMS TO BE RETAINED BY
<br />WALMART PRIOR TO REMOVAL OF THE EQUIPMENT SHOWN
<br />ON THE DEMOLITION PLANS. THE CONTRACTOR SHALL
<br />CAREFULLY REMOVE ANY ITEMS TO BE RETAINED BY
<br />WALMART AND DELIVER THOSE ITEMS, READY FOR
<br />SHIPMENT, TO THE WALMART MECHANICAL SERVICES
<br />CONSTRUCTION MANAGER. ALL REMOVED ITEMS NOT
<br />ALLOCATED FOR SALVAGE BY WALMART SHALL BE THE
<br />CONTRACTOR'S RESPONSIBILITY TO IMMEDIATELY REMOVE
<br />FROM THE JOB SITE AND ARRANGE DISPOSAL IN
<br />ACCORDANCE WITH LOCAL CODES.
<br />DEMOLITION NOTES
<br />1. THE CONTRACTOR SHALL REMOVE EXISTING
<br />REFRIGERATED CASES AND EQUIPMENT AS SHOWN ON
<br />DEMOLITION PLAN. PROPERLY PUMP DOWN AND
<br />RECYCLE REFRIGERANT. PREPARE FOR DISPOSAL.
<br />PROMPTLY HAUL OFF AND PROPERLY DISPOSE OF
<br />AND/OR RECYCLE ALL EQUIPMENT REMOVED FROM
<br />STORE.
<br />2. WHERE APPLICABLE COOLER PANEL MANUFACTURER
<br />SHALL DEMOLISH AND PROMPTLY HAUL OFF WALK—IN
<br />PANELS AND DOORS TO BE REPLACED.
<br />3. DURING DEMOLITION AND RECONSTRUCTION PHASES,
<br />COORDINATE LOCATION OF ALL DUST WALLS AND
<br />SECURITY ENCLOSURES WITH WALMART STORE
<br />MANAGER. REFER TO DUST WALL DETAIL.
<br />4. ALL NEW EQUIPMENT MUST BE ON SITE PRIOR TO
<br />STARTING ANY DEMOLITION OR CONSTRUCTION.
<br />5. PATCH/REPAIR FLOOR COVERING AS REQUIRED AFTER
<br />INSTALLATION OF NEW CASES. MATCH EXISTING
<br />FLOORING TYPE, COLOR, PATTERN, AND FINISH.
<br />Ld o a
<br />W err; 1
<br />22JFF aZ�Wtl1��Z
<br />W � ~4ao� �a
<br />o a
<br />o �
<br />%W 04 ,0MyZ QN3
<br />O wQMN,g>-,cwna``'avoog
<br />�nk'Z��v`oXcnw$�a
<br />cr
<br />3in�Z���w�Zaw�Fo
<br />0 �� 0w
<br />1— o�aowoc�is:2mwzr
<br />$ W' w� viwv_ia
<br /><�Zo�WFwr�W"~Z
<br />WWZU
<br />F- Wavwoc�ao
<br />w000-co
<br />,�
<br />Mjwo�awwwzn'irw
<br />wTzo_jwo awo0_m
<br />ISSUE BLOCK
<br />CHECKED BY: - RDF/JAL
<br />DRAWN BY: RDF
<br />DOCUMENT DATE: 01 /03/12
<br />FIXURE
<br />PLANS
<br />AND
<br />DETAIL
<br />SHEET:
<br />Fl