My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7809 Gall Blvd (4)
Zephyrhills
>
Building Department
>
Building Plans
>
7809 Gall Blvd (4)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2025 10:03:13 AM
Creation date
2/25/2025 4:20:21 PM
Metadata
Fields
Template:
Building Plans
Street #
7809
Location
Gall Blvd
Contractor
Powerhouse Retail Service
Building Plans - Permit #
3480
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E <br />REFLECTED CEILING PLAN SCALE <br />.0„ 2 <br />REFLECTED CEILING PLAN KEYNOTES: <br />�1 PROVIDE VAT TUBE TRIM PIECE AT CEILING AS REQUIRED FOR VAT <br />SYSTEM. PATCH/PAINT GYP TO MATCH ADJACENT AS REQUIRED FOR <br />NEW WORK. <br />2 VAT ENCLOSURE SEE SHEET A-9.1 FOR MORE INFORMATION. ALIGNMENT <br />AND POSITION OF ENCLOSURE IS TO BE CENTERED AROUND VAT TUBE. <br />COORDINATE ENCLOSURE LOCATION WITH VAT VENDOR & TUBE <br />ROUTING. <br />.3 EXISTING CANOPY LIGHT FIXTURE TO REMAIN. PROTECT DURING <br />CONSTRUCTION. <br />4, DIAGRAMMATICAL ROUTE OF VAT TUBE ABOVE CANOPY/CEILING INTO <br />- BAKING CENTER. VENDOR TO FIELD FIT VAT TUBE AROUND EXISTING <br />HAVC AND ELECTRICAL WORK AS REQUIRED TO ACHIEVE FINAL <br />PLACEMENT AT TELLER LINE AS SHOWN ON 1/A-2.2. <br />5 PROVIDE LOCKABLE ACCESS PANEL AS SHOWN. COORDINATE KEYING <br />REQUIREMENTS WITH OWNERS REP. <br />E SCAL <br />REFLECTED CEILING PLAN SCALE <br />1 <br />REFLECTED CEILING PLAN SHEET NOTES <br />A. COORDINATE THE WORK OF ALL TRADES INVOLVED IN CEILING WORK TO ENSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, <br />CEILING SUSPENSION SYSTEM, ETC., NECESSARY TO MAINTAIN THE EXISTING FINISHED CEILING HEIGHTS. VERIFY IN FIELD. <br />B. PROVIDE (UL) LABELED DEVICES THROUGHOUT, INCLUDING FIXTURES, ASSOCIATED TRIM, FIXTURE LAMPS, AND SEISMIC <br />BRACING AS REQUIRED. <br />C. LIGHT FIXTURES, EXIT SIGNS, SPRINKLERS AND OTHER CEILING ELEMENTS SHALL BE LOCATED IN CENTER OF INDIVIDUAL <br />CEILING TILE U.N.O. <br />D. PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM MAINTENANCE, MATCH ADJACENT CEILING FINISH U.N.O. <br />E. ARCHITECTURAL DRAWINGS DETERMINE LOCATION AND HEIGHTS OF CEILING TYPES, LIGHT FIXTURES, AND ASSOCIATED ITEMS, <br />U.N.O. <br />F. REFER TO ENGINEERING DRAWINGS FOR LIGHTING SCHEDULES, CIRCUITING, WIRING LAYOUT, AND ADDITIONAL INFORMATION. <br />G. ALL SPECIFIC INFORMATION CONCERNING INSTALLATION OF VARIOUS ABOVE -CEILING ELEMENTS ARE TO BE FOUND IN THE <br />HVAC, ELECTRICAL AND LIGHTING DRAWINGS. <br />H. NOTIFY ARCHITECT OF ANY CONFLICTS OF LIGHT FIXTURE LOCATIONS WITH MAIN RUNNERS, DUCTS, STRUCTURES, HVAC, <br />AND/OR CONDUIT, PRIOR TO FRAMING FOR LIGHTING. ANY DISCREPANCIES BETWEEN ARCHITECTS CEILING GRID LOCATION & <br />ACTUAL FIELD CONDITIONS ARE TO BE CLARIFIED WITH THE ARCHITECT PRIOR TO FRAMING. <br />I. INSTALL LIGHT FIXTURES WITH PROTECTIVE FILM OR SIMILAR COVER OVER LOUVER, LENS, BAFFLE AND THE LIKE, TO AVOID <br />FIXTURE SOILING OR DAMAGE, FIXTURES SHALL BE MAINTAINED CLEAN AND AS NEW; LAMPS SHALL BE NEW AT PROJECT <br />COMPLETION. <br />J. REFER TO ENGINEERING DRAWINGS FOR LIFE SAFETY DEVICES REQUIRED BY CODE AND EMERGENCY LIGHT FIXTURES. <br />ENGINEERING DRAWINGS SHALL ALSO GOVERN LOCATION OF THESE DEVICES. <br />K. AT ALL LOCATIONS OF PERFORATED RETURN AIR GRILLES: ALL WIRING, CABLING, ETC. TO BE HELD CLEAR OF OPEN LINE OF <br />SIGHT THROUGH GRILLE. <br />L. ALL SWITCHES AND DIMMERS SHALL BE LOCATED 48" ABOVE FINISHED FLOOR TO TOP OF SWITCH U.N.O. <br />M. MULTIPLE SWITCHES AT ONE LOCATION SHALL BE GANGED TOGETHER AND FINISHED WITH ONE COVER PLATE U.N.O. <br />N. COLOR OF LIGHT SWITCH DEVICES, OUTLETS AND COVER PLATES TO BE WHITE; U.N.O. OR AS RESTRICTED BY CODE. <br />O. NO SWITCHES OR THERMOSTATS TO BE LOCATED BEHIND DOORS OR FURTHER THAN 6" PAST THE ADJACENT DOOR FRAME. <br />PROVIDE WALL BRIDGING AS REQUIRED, U.N.O. <br />P. NO STROBES OR THERMOSTATS SHALL BE LOCATED IN THE CENTER OF A WALL. ALL STROBES SHALL BE PLACED OFF CENTER IN <br />WALL AT 80" A.F.F. TO THE CENTERLINE OF THE STROBE. REFER TO ENGINEERING DRAWINGS FOR THERMOSTAT POSITIONS AND <br />LOCATION. <br />Q. GYPSUM BOARD CEILINGS LOCATED IN RESTROOMS, KITCHENS, OR OTHER DAMP AREAS TO BE MOLD AND MOISTURE <br />RESISTANT TO MEET ASTM STANDARDS. <br />N <br />O <br />N <br />ti <br />N <br />z <br />U <br />a <br />z <br />z <br />Q <br />� <br />� <br />o <br />N <br />W <br />a <br />a') <br />Of <br />O <br />LL <br />w <br />D <br />U) <br />U) <br />0 <br />z <br />INFINITY ENGINEERING <br />GROUP, LLC <br />1208 Fast Kennedy Boulevard <br />Suite 230 <br />Tampa) Florida 33602 <br />[p]; 813.434.4770 <br />[fl. 813.445.4211 <br />www.iegroup.net <br />FL Cert. of Auth. No. 27889 <br />❑aTa <br />� <br />NISIT SAPPARKHAO, P.E. <br />FL REG..NO. 64085 <br />I \GENS® <br />a <br />No 640 <br />ST E OF ;1JJ� <br />Dale- <br />LO <br />z <br />M <br />ch <br />� <br />V- <br />O <br />J <br />J <br />z <br />= <br />U) <br />_Z <br />_J <br />J <br />a <br />W <br />= <br />W <br />N <br />U <br />d <br />0 <br />co <br />�— <br />� <br />W <br />� <br />U <br />N <br />c� <br />LL) <br />o <br />LL <br />M <br />E <br />00 <br />W <br />z <br />U <br />ai <br />F <br />o <br />a <br />(D <br />_r_ <br />v) <br />'Project No. Sheet ` <br />280-22.00 <br />Date A— A . 1 <br />AS NOTED L•� <br />Scale <br />AS NOTED A <br />
The URL can be used to link to this page
Your browser does not support the video tag.