Laserfiche WebLink
AD-1 DEMOLITION FLOOR PLAN GENERAL NOTES: <br />A. DEMOLITION INCLUDES BUT IS NOT LIMITED TO ITEMS SHOWN DASHED. <br />B. THE CONTRACTOR SHALL FIELD VERIFY THE EXTENT OF DEMOLITION. <br />C. GENERAL CONTRACTOR TO VERIFY ALL CONDITIONS PRIOR TO DEMOLITION. <br />DISCREPANCIES BETWEEN DESIGN AND EXISTING CONDITIONS SHALL BE BROUGHT TO <br />THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH WORK. <br />D. CARE SHALL BE TAKEN DURING DEMOLITION SO AS TO NOT DAMAGE OR ALTER ANY <br />EXISTING STRUCTURAL MEMBERS OTHER THAN THOSE DESCRIBED IN THESE <br />DOCUMENTS. THE PUBLIX REPRESENTATIVE SHALL BE NOTIFIED IMMEDIATELY IF ANY <br />DAMAGE OCCURS, OR IS DISCLOSED DURING DEMOLITION. CARE SHALL BE TAKEN TO <br />INSURE SUPPORT IS PROVIDED WHEREVER DEMOLITION IS PERFORMED. <br />E. SALVAGED MATERIAL OF VALUE IS PUBLIX OWNED, COORDINATE WITH PUBLIX <br />REPRESENTATIVE. <br />F. REFER TO ENGINEERING PLANS FOR EXTENT OF MECHANICAL, ELECTRICAL, PLUMBING & <br />STRUCTURAL DEMOLITION. <br />G. G.C. TO PROTECT SLAB FROM DAMAGE IN AREAS TO REMAIN. REFER TO SHEET S-1 FOR <br />SLAB REMOVAL COORDINATION. <br />H. ALL OBJECTS LOCATED IN PATH OF ENTRANCE VESTIBULE EMERGENCY BREAKAWAY <br />DOORS, SHALL BE REMOVED BY STORE ASSOCIATE, TO ALLOW FOR ACCESS <br />CLEARANCES. <br />HISSYMBOLBYO <br />DEMOLITION FLOOR PLAN KEY NOTES: TEFERENCE <br />NOTE: ONLY NUMBERED KEYNOTES APPLY TO THIS STORE <br />1O <br />EQUIPMENT TO BE RELOCATED. <br />2O <br />REFER TO STRUCTURAL SHEETS FOR EXTENT OF SLAB DEMOLITION. <br />O <br />REMOVAL OF DIETITIANS OFFICE TO BE SEQUENCE AS CLOSE TO THE END OF THE <br />REMODEL AS POSSIBLE. <br />O <br />PORTION OF EXISTING COOLER WALL TO BE REMOVED. MATCH ADJACENT EXISTING <br />HEIGHT. <br />O5 <br />REMOVE HOOD, RELATED DUCTWORK AND OTHER COMPONENTS. <br />6O <br />REMOVE END PANEL FROM EXIST GONDOLA BACK. <br />O <br />REMOVE PORTION OF WALL AS SHOWN. <br />8� <br />REMOVE STEEL WHEELS FROM COMPACTOR. <br />9O <br />REMOVE CONCRETE SLAB. REF STRUCTURAL FOR EXTENT OF WORK. <br />10 <br />REMOVE STONE VENEER IN FRONT OF ATM AS NOTED. <br />AD-2 DEMOLITION REFLECTED CEILING KEY NOTES: TEFERENCE <br />HISSYMBOLBYO <br />NOTE: ONLY NUMBERED KEYNOTES APPLY TO THIS STORE <br />OREMOVE EXISTING LIGHTS, SPRINKLERS AND DIFFUSERS. REF: MECH, ELECTRICAL AND <br />FIRE PROTECTION FOR ADDITIONAL INFORMATION. <br />2O REMOVE ACOUSTICAL CEILING TILE AND GRID AS INDICATED. <br />3O PATCH AND REPAIR CEILING AS NEEDED. <br />4O EXISTING LIGHT FIXTURE SHOWN FOR REFERENCE ONLY. <br />O REMOVE PORTION OF CEILING SYSTEM IN PREPARATION OF NEW ROOM <br />O REMOVE EXISTING GREASE HOOD. REF. MECHANICAL FOR MORE INFORMATION. <br />EQ-1 EQUPIMENT PLAN GENERAL NOTES: <br />A. EXIT PATH SHALL BE MAINTAINED TO EXIT DOORS CLEAR FLOOR SPACE. IN ADDITION, <br />REAR CORRIDORS SHALL MAINTAIN A 44" WIDE EGRESS PATH. <br />B. STOCK STACKING LIMITS SHALL BE OBSERVED. <br />C. ELECTRICAL PANELS SHALL MAINTAIN A 30"W X 36"D X 78"H CLEAR FLOOR SPACE, AND <br />ELECTRICAL ROOM SHALL BE FREE OF STORED ITEMS. <br />D. FOR NEW MILLWORK, SEE SUP PLANS PROVIDED BY PUBLIX. <br />E. PROVIDE METAL CLOSURE AT TOP, SIDES, AND BOTTOM OF CASES AS REQUIRED FOR <br />THE FUNCTION OF R/A CIRCULATION AND/OR SEALING DAIRY COOLER OPENING, BY <br />REFRIGERATION CONTRACTOR. <br />F. CONTRACTOR SHALL VERIFY ALL EXISTING SITE CONDITIONS, DIMENSIONS AND <br />ELEVATIONS IN THE FIELD AND REPORT ANY DISCREPANCIES AND/OR OMISSIONS <br />WHICH WOULD INTERFERE WITH SATISFACTORY COMPLETION OF THE WORK. <br />G. CONTRACTOR SHALL COORDINATE LOCATION OF ACCESSIBLE SIGNAGE, <br />DISPENSERS, AND AMENITIES WITH PUBLIX REPRESENTATIVE IN THE FIELD. ITEMS <br />NOT SHOWN ON THIS PLAN OR ADDED IN THE FIELD MUST COMPLY W/ FBC. <br />H. PUBLIX TO PROVIDE SPLASHGUARD, IF NOT EXISTING, AT SIDE(S) OF HANDSINK <br />WHERE HANDSINK IS WITHIN 12" OF SINK, FOOD PREP OR COOKING EQUIPMENT. <br />I. ALL COUPON DISPLAYS SHALL BE MOUNTED BETWEEN 24" AFF AND 54" AFF AND <br />WITHIN A 10" SIDE REACH. <br />J. REMOVE ALL PLASTIC BAG DISPENSERS AND PAPER TOWEL DISPENSERS THAT ARE <br />NOT LOCATED 48"H MAX AFF AND WITHIN 12" OF AISLE. REPLACE W/ NEW FLOOR <br />MOUNTED ACCESSIBLE DISPENSER STAND. <br />K. ALARM SYSTEM (BY OTHERS) SHALL HAVE AUDIOVISUAL SIGNAL ALARMS IN <br />COMPLIANCE W/ FBC. <br />EQUIPMENT PLAN KEY NOTES:REFERENCED <br />BYTHIS SYMBOL D <br />NOTE: ONLY NUMBERED KEYNOTES APPLY TO THIS STORE <br />11 NEW MILLWORK BY PUBLIX. REF SUP PLANS PROVIDED BY PUBLIX. <br />2] NEW CASE TRIM TO MATCH EXIST/ADJACENT CASE TRIM. <br />3❑ PATCH PASS THRU AS REQUIRE. <br />❑4 MAINTAIN 5'-0" CLEAR FLOOR SPACE IN FRONT OF ENTRANCE/EXIT VESTIBULE BREAKAWAY <br />DOORS AS INDICATED. <br />5❑ NEW WALL. REF SHEET A-1 FOR ADDITIONAL INFORMATION. <br />6] NEW COUNTERTOP BY PUBLIX. <br />7❑ RESKIN COUNTERTOP. <br />❑RELOCATE COUPON DISPENSER TO A HEIGHT NO LESS THAN 24" AND NO GREATER THAN <br />48"H WITHIN 10" REACH. <br />❑9 NEW WEATHER SEAL STRIPS TO BE PUT ON BREAKAWAY DOORS. <br />10 MAINTAIN AISLES 36" MIN. CLEAR ACCESSIBLE PATH. <br />11 RELOCATED OR PROVIDED NEW, BY PUBLIX, OVERHEAD SIGN W/ INTERNATIONAL <br />El <br />WHEELCHAIR SYMBOL AND MESSAGE "POWERED SHOPPING CARTS," REF SIGN "P" 2/A-2. <br />12 PUBLIX TO PROVIDE OVERHEAD SIGN W/ INTERNATIONAL WHEELCHAIR SYMBOL AND <br />MESSAGE "ASSISTANCE ID AVAILABLE UPON REQUEST," REF SIGN "N" 2/A-2. <br />13 NEW CHAIN LINK WITH LOCK. REF: DETAILS 17-20/A-18. <br />GC TO PROVIDE THE NECESSARY STRUCTURAL ANCHORS AND SUPPORT FOR THE <br />14 OVERHEAD ELEMENT INCLUDING RESOLUTION OF ANY CONFLICTS WITH POTENTIAL <br />OBSTRUCTION OR MECHANICAL DUCTS/ EQUIPMENT. <br />RELOCATE PER PLAN OR AS NEW LINEUP REQUIRES. REPLACE POLES AS FIELD <br />15 DETERMINED TO BE DAMAGE. <br />16 NEW 60" TALL WING WALL. <br />17 NEW BOLLARDS, REF: DETAILS 5/A-2 FOR ADDITIONAL INFORMATION. <br />18 NEW POLYMER WHEELS FOR THE COMPACTOR. <br />19 NEW FALSE COLUMN. REF: REFRIGERATION. <br />20 NEW GATE BY PUBLIX. <br />©1 MAINTAIN T-0" IN FRONT OF ELECTRICAL PANELS. <br />©2 NEW FULL HEIGHT WALL. <br />23 NEW 8"X8" FALSE COLUMN. <br />24 REMOVE AND REPLACE SOFFIT AS REQUIRED TO REPLACE EQUIPMENT. <br />a NEW 52" WALL. REF SHEET A-1 FOR ADDITIONAL INFORMATION. <br />RELOCATE CUSTOMER USE BAGS AT OR BELOW A HEIGHT OF 48" AFF AND WITHIN 10" SIDE <br />26 REACH. <br />©7 RELOCATE CCTV EQUIPMENT PROTOTYPICALLY BACK TO SERVER RACK. <br />28 PUBLIX TO PROVIDE TACTILE BRILLE SIGN ON WALL OR DOOR. REF SHEET A-2. <br />ADJUST DOOR CLOSER TO REQUIRE 5LBS OR LESS PUSH PULL FORCE AND A MINIMUM OF 5 <br />SECONDS FOR THE DOOR TO CLOSE FROM 900 OPEN TO 120 FROM THE STRIKE. <br />30 INSULATE SUPPLY AND WASTE PIPES AT THE SINK. <br />31 REMOUNT TIME CLOCK AT NO GREATER THAN 48" A.F.F. <br />A-1 FLOOR AND FINISH PLAN KEY NOTES: REFERENCED <br />BYTHISSYMBOL <br />NOTE: ONLY NUMBERED KEYNOTES APPLY TO THIS STORE <br />D PATCH AND REPAIR FLOOR TO MATCH EXISTING FLOOR FINISH, AS NECESSARY. <br />2❑ REFER TO STRUCTURAL SHEET FOR EXTENT OF THE SLAB WORK. <br />❑ REFER DETAIL 24/A-18 FOR WALL SECTION. <br />A-3 RELFECTED CEILING PLAN GENERAL NOTES: <br />A. ALL NEW CEILINGS TO BE CLASS. <br />B. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. <br />C. EXAMINE EXISTING REFRIGERATION CHASES FOR POSSIBLE REUSE. REBUILD ACCORDING <br />TO DETAIL 10 OR 11/A-18 AS APPLICABLE. <br />D. GC TO PROVIDE AND INSTALL TWO #10 SAFETY WIRES PER ALL NEW AND IMPROPERLY <br />SUPPORTED EXISTING METAL HALIDE AND FLUORESCENT FIXTURES. ATTACH TO JOIST AT <br />PROPER LOCATION AS COORDINATED WITH ELECTRICAL CONTRACTOR. (ELECTRICAL <br />SHALL ATTACH TO FIXTURE). <br />E. WHERE CEILING HEIGHTS CHANGE, PROVIDE A BULKHEAD AS REQUIRED. REF DETAIL <br />14/A-14. <br />F. EXISTING DUCTWORK, DIFFUSERS, LIGHTS AND SPRINLER HEADS SHOWN FOR <br />REFERENCE ONLY NOT INCLUDED IN SCOPE OF WORK. <br />G. ALL LAY -IN CEILING MUST BE INSTALLED PER IBC LOCAL SEISMIC CATEGORY <br />REQUIREMENTS. <br />H. ALL FOOD PREPARATION AREAS GET IN VINYL FACED CEILING TILE. SEE PLAN A-2 ROOM <br />FINISHES SCHEDULE. <br />REFLECTED CEILING PLAN KEY NOTES:REFERENCED <br />BY THIS SYMBOL p <br />NOTE: ONLY NUMBERED KEYNOTES APPLY TO THIS STORE <br />1❑ INSTALL NEW PORTION OF CEILING SYSTEM AS INDICATED. <br />2❑ NEW GREASE HOOD. REF MECHANICAL FOR ADDITIONAL INFORMATION. <br />D NEW TRACK LIGHTS. REF: ELECTRICAL FOR ADDITIONAL INFORMATION. <br />4❑ NEW DIFFUSER. REF: MECH FOR ADDITIONAL INFO. <br />NEW OR RELOCATED FIRE SPRINKLER AS SHOWN. REF: FIRE PROTECTION FOR <br />5 ADDITIONAL INFORMATION. <br />6❑ NEW LIGHT FIXTURE. REFER TO ELECTRICAL DRAWINGS FOR MORE INFORMATION. <br />7❑ INSTALL NEW SOFFIT SYSTEM AS INDICATED. <br />❑ CLEAN ACOUST TILE. <br />9❑ CLEAN VINYL CEILING. <br />10 CLEAN INSULATED CEILING. <br />11 NEW GREASE HOOD. REF MECHANICAL FOR MORE INFORMATION. <br />A-5 ROOF PLAN GENERAL NOTES: <br />A. INFORMATION SHOWN IN HERE IS EXISTING UNLESS SPECIFICALLY NOTED <br />OTHERWISE. FIELD VERIFY LOCATION OF ALL EXISTING COMPONENTS. <br />B. COORDINATE WITH HVAC, PLUMBING, REFRIGERATION AND STRUCTURAL <br />DRAWINGS FOR EXACT LOCATION OF EQUIPMENT. <br />C. CONTRACTOR TO PATCH ROOFING SYSTEM AS NECESSARY TO MATCH <br />EXISTING. REF: STRUCTURAL FOR ADDITIONAL INFORMATION. <br />D. CONTRACTOR SHALL INSTALL CRICKETS TO DIVERT WATER AT NEW <br />EQUIPMENT. <br />ROOF PLAN KEY NOTES: <br />REFERENCED # <br />BY THIS SYMBOL <br />NOTE: ONLY NUMBERED KEYNOTES APPLY TO THIS STORE <br />9❑ EXISTING CURB AND CRICKET. <br />❑PAINT EXISTING ROOF BENCH USING RUST RESISTANT PAINT. REF: STRUCTURAL SHEETS <br />FOR ADDITIONAL INFORMATION. <br />❑ EXISTING EQUIPMENT TO BE REMOVED. <br />❑NEW FAN AND CURB. REF: MECH & STRUCTURAL FOR <br />ADDITIONAL INFORMATION. <br />N <br />�00 <br />00 <br />u <br />U <br />7� <br />v <br />0 <br />r-•+ <br />w <br />o <br />w <br />rn <br />QN <br />0 <br />N <br />z <br />W > <br />W <br />W <br />U <br />J LO <br />� <br />W v! <br />O <br />O <br />U <br />w <br />0 <br />p <br />a <br />Lo <br />a <br />s <br />� <br />0 <br />o <br />U) <br />z <br />h <br />a <br />OU <br />o <br />c <br />c <br />0 <br />3 <br />U <br />m <br />g <br />M <br />N <br />(:D <br />s_ <br />L0 <br />M <br />W <br />N <br />o <br />< <br />~ <br />of <br />s <br />�C <br />O <br />X <br />o LL <br />J� <br />w <br />m J <br />zMQ� <br />ULLI <br />C� <br />'' <br />d <br />LLI <br />g a <br />ti N <br />4� <br />w <br />Q <br />LU <br />dyo <br />W J <br />LL <br />d' • <br />•.G�y <br />m <br />0 <br />CV <br />J <br />N <br />J <br />m <br />U) <br />QU <br />W <br />� <br />J <br />w <br />O <br />o <br />z <br />M <br />N <br />U <br />ado <br />N <br />w <br />U <br />� <br />N <br />w <br />C) <br />Z <br />0 <br />ui <br />O. <br />0 <br />0 <br />U <br />000 <br />2019 <br />Hawkins Construction, Inc <br />