GENERAL <br />A. ALL WORK SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE <br />2014, AS ADOPTED AND SUPPLEMENTED BY LOCAL REGULATION. <br />B. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS <br />AND CONDITIONS AT THE SITE AND SHALL NOTIFY THE ARCHITECT/ENGINEER <br />OF DISCREPANCIES BETWEEN THE ACTUAL CONDITIONS AND INFORMATION <br />SHOWN ON THE DRAWINGS BEFORE PROCEEDING WITH WORK. <br />C. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT <br />THE COMPLETE DESIGN OF THE STRUCTURE. THEY DO NOT INDICATE THE <br />MEANS AND METHODS OF CONSTRUCTION UNLESS SO STATED OR NOTED. <br />THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT <br />THE WORKERS, OR THEIR PERSONS DURING CONSTRUCTION. <br />D. OBSERVATION VISITS TO THE SITE BY FOR OR REPRESENTATIVES OF THE FOR <br />MAY BE MADE DURING CONSTRUCTION. ANY SUPPORT SERVICES <br />PERFORMED HEREIN SHALL BE DISTINGUSHED FROM INSPECTION AND.OR <br />TESTING SERVICES PERFORMED BY OTHERS, AND ARE NOT TO BE <br />CONSTRUED AS SUPERVISION AND/OR MANAGEMENT OF CONSTRUCTION. <br />E. THE CONTRACTOR SHALL PROVIDE TEMPORARY ERECTION BRACING AND <br />SHORING OF ALL STRUCTRUAL MEMBERS AS REQUIRED FOR STABILITY OF <br />THE STRUCTURE DURING ALL PHASES OF CONSTRUCTION. THE CONTRACTOR <br />SHALL IMMEDIATELY NOTIFY THE ARCHITECT/ENGINEER OF ANY CONDITION <br />WHICH, IN HIS OPINION, MIGHT ENDANGER THE STAILITY OF THE STRUCTURE <br />OR CAUSE DISTRESS WITHIN THE STRUCTURE. <br />F. CONSTRUCTION MATERIALS SHALL NOT BE STACKED ON FLOORS OR ROOFS IN <br />EXCESS OF THE DESIGN LIVE LOADS WHICH ARE INDICATED IN THE GENERAL <br />NOTES. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO ENSURE THAT <br />THE SUBCONTRACTORS ARE INFORMED AND DO NOT VIOLATE THIS IMPORTANT <br />REQUIREMENT. IMPACT SHALL BE AVOIDED WHEN PLACING MATERIALS ON <br />FLOORS OR ROOFS. <br />G. DRAWINGS ARE NOT TO BE SCALED. <br />H. FOR ACTUAL ELEVATION ON FIRST FLOOR (REF. ELEV. 0'4" HEREIN), SEE SITE <br />PLAN. <br />J. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. <br />WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF <br />SIMILAR CHARACTER TO THE DETAILS PRESENTED,SIMILAR DETAILS SHALL BE <br />USED SUBJECT TO THE REVIEW OF ENGINEER OF RECORD. <br />K. SUBMIT WRITTEN REQUEST TO THE ARCHITECT FOR APPROVAL OF ANY <br />PROPOSED CHANGE TO THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. <br />SPLICING, CUTTING, NOTCHING OR OTHER ALTERATIONS TO STRUCTURAL <br />MEMBERS ARE NOT PERMITTED WITHOUT WRITTEN AUTHORIZATION OF THE <br />ENGINEER. ANY UNAUTHORIZED DEVIATION FROM THE CONTRACT <br />DOCUMENTS, AND CORRECTION THEREOF, IS THE RESPONSIBILITY OF THE <br />CONTRACTOR. SUBSEQUENT DOCUMENTATION/REQUESTS TO BUILDING <br />ENGINEERING OF RECORD FROM GC SHALL INCLUDE EVALUATION OF <br />DEVIATIONS BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF <br />FLORIDA. <br />L. THE MOST STRINGENT REQUIREMENTS APPLY IN CASE OF CONFLICT BETWEEN <br />SPECIFICATIONS, STANDARDS, CODES AND DRAWINGS. <br />M. DESIGN DATA <br />ROOF LIVE LOADS: 20 PSF <br />ROOF DEAD LOADS: 20 PSF <br />WIND LOADING <br />1. ULTIMATE DESIGN WIND SPEED, V_ULT: 137 MPH <br />2. NOMINAL WIND SPEED, V_ASD: 107 MPH <br />3. RISK CATEGORY (TABLE 1.5-1, ASCE7): 11 <br />4. WIND EXPOSURE: C <br />5. ENCLOSURE CLASSIFICATION: ENCLOSED (+/- 0.18) <br />6. COMPONENT AND CLADDING: SEE CHARTS THIS SHEET <br />SUBMITTALS <br />A. SHOP DRAWING REVIEW IS FOR GENERAL CONFORMANCE WITH THE <br />DESIGN CONCEPT. CORRECTIONS OR COMMENTS MADE ON THIS REVIEW <br />DO NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY FOR ERRORS <br />AND OMMISIONS, AND FROM COMPLIANCE WITH THE PLANS AND <br />SPECIFICATIONS. CORRECTIONS OR COMMENTS DO NOT AUTHORIZE AN <br />INCREASE IN THE CONSTRUCTION BUDGET. <br />B. APPROVAL OF SHOP DRAWINGS DOES NOT INDICATE ACCEPTANCE OF <br />DEVIATIONS FROM CONTRACT DOCUMENTS OR PREVIOUS SHOP <br />DRAWING REVIEW, UNLESS SPECIFICALLY NOTED THEREIN BY ENGINEER <br />OF RECORD. <br />C. ANY CHANGES TO THE DESIGN CONCEPT SHOWN IN CONTRACT <br />DOCUMENTS SHALL BE SUBMITTED IN WRITING AND APPROVED BY THE <br />ARCHITECT AND ENGINEER PRIOR TO SUBMITTING SHOP DRAWINGS. ALL <br />SUCH CHANGES SHALL BE "BUBBLED" ON THE SHOP DRAWINGS AND <br />REFERENCED TO THE PROPER R.F.I. <br />D. SUBMITTALS SHALL CONFORM TO THE REQUIREMENTS OF THE <br />CONTRACT DRAWINGS (REFERENCE ITEM C ABOVE FOR EXCEPTION). <br />NON -CONFORMING OR NON -REVIEWED SUBMITTALS WILL BE RETURNED <br />WITHOUT REVIEW. <br />1. SHOP DRAWINGS SHALL BE "APPROVED", SIGNED AND DATED BY <br />THE GENERAL CONTRACTOR PRIOR TO SUBMITTAL TO <br />ENGINEER AND ARCHITECT OF RECORD. <br />2. SHOP DRAWINGS SHALL NOT CONTAIN REPRODUCTIONS OF <br />THE CONTRACT DRAWINGS. <br />3. SUBMITTAL REQUIREMENTS: <br />SHOP DRAWINGS/DATA TO BE SUBMITTED FOR APPROVAL <br />CONCRETE MIX DESIGNS (INDICATE INTENDED USE OF <br />EACH) <br />REINFORCING STEEL <br />STRUCTURAL STEEL (INCLUDING JOISTS & JOIST GIRDERS) <br />METAL DECK <br />SHOP DRAWINGS/DATA TO BE SUBMITTED FOR APPROVAL. <br />SUBMITTALS SHALL BE SIGNED AND SEALED BY A <br />REGISTERED PROFESSIONAL ENGINEER LISCENCED IN THE <br />STATE OF THE PROJECT <br />LIGHT GAUGE TRUSS SYSTEMS <br />RTU TIE DOWNS <br />E. PROVIDE COPIES OF MANUFACTURERS LITERATURE FOR ALL MATERIALS <br />AND PRODUCTS USED IN CONSTRUCTION ON THE PROJECT. <br />FOUNDATIONS/SITE WORK <br />A. FOUNDATION DESIGN IS BASED UPON THE FOLLOWING SOILS RFPORT- <br />NO REPORT PROVIDED: <br />PRIOR TO CONSTRUCTION, CONTRACTOR SHALL RETAIN THE SERVICES OF A <br />QUALIFIED GEOTECHNICAL ENGINEER. THE GENERAL CONTRACTOR HEREIN <br />IS RESPONSIBLE FOR PERFORMING ALL EARTHWORK OPERATIONS IN <br />STRICT ACCORDANCE WITH GEOTECHNICAL ENGINEERING REQUIREMENTS. <br />IF THE FOUNDATION RECOMMENDATIONS AN/OR DESIGN VALUES DIFFER <br />FROM THAT ASSUMED, MODIFICATIONS TO THE DRAWINGS MAY BE <br />REQUIRED. <br />DO NOT PLACE CONCRETE PRIOR TO GEOTECHNICAL APPROVAL. <br />B. ALLOWABLE IL PRESSURE <br />SO SSU E ASSUMED TO BE 2000 PSF (REF A., ABOVE). <br />SHALLOW FOUNDATION SYSTEM IS ASSUMED TO BE ADEQUATE. <br />ESTIMATED SETTLEMENT ASSUMED TO BE NO GREATER THAN 1" OVERALL <br />AND 1/2" DIFFERENTIAL SETTLEMENT. IT IS ASSUMED THAT ALL <br />PROBLEMATIC SOILS (ORGANIC, EXPANSIVE, ETC.) WILL BE REMOVED AND <br />REPLACED WITH SUITABLE STRUCTURAL FILL. <br />C. ANY FILL REQUIRED TO BACKFILL EXCAVATED AREA OR ACHIEVE FINISHED <br />GRADE IN STRUCTURAL AREAS SHALL BE AS INDICATED BY GEOTECHNICAL <br />ENGINEER. THE FILL SHALL BE PLACED IN LEVEL LIFTS NOT EXCEED 12 <br />INCHES LOOSE THICKNESS AND COMPACTED TO A MINIUM OF 95% OF THE <br />SOIL'S MODIFIED PROCTOR MAXIMUM DRY DENSITY AS DETERMINED BY <br />ASTM SPECIFICATION D-1557. <br />D. IN -PLACE DENSITY TESTS SHALL BE PERFORMED BY AN EXPERIENCED <br />ENGINEERING TECHNICIAN. TESTS SHALL BE PERFORMED FOR EACH 2,000 <br />SQUARE FEET, IN EVERY COLUMN FOOTING LOCATION AND EACH 50 FEET <br />ALONG WALL FOOTINGS. COPIES OF THE TEST REPORTS SHALL BE <br />FURNISHED TO THE STRUCTURAL ENGINEER. <br />E. REMOVE FREE WATER FROM EXCAVATIONS BEFORE PLACING CONCRETE. <br />F. CAUTION SHOULD BE USED WHEN OPERATING VIBRATORY COMPACTING <br />EQUIPMENT NEAR THE EXISTING STRUCTURE TO AVOID THE RISK OF <br />DAMAGE TO THE STRUCTURE. <br />G. REFER TO ARCHITECTURE DRAWINGS FOR ANY NECESSARY <br />WATERPROOFING REQUIREMENTS. <br />REINFORCED CONCRETE <br />A. CONCRETE WORK SHALL CONFORM TO ACI SPECIFICATIONS, CODES AND <br />STANDARDS. <br />B. CAST -IN -PLACE CONCRETE, UNLESS OTHERWISE NOTED (U.O.N.): <br />PORTLAND CEMENT PER ASTM C150 <br />PROPORTIONED FOR MAX. ALLOWABLE UNIT SHRINKAGE OF 0.03% <br />25% MAXIMUM FLYASH BY WEIGHT <br />SLABS <br />4000 PSI 28-DAY COMPRESSIVE STRENGTH, NORMAL WEIGHT, <br />MAXIMUM AGGREGATE SIZE OF 1", 0.55 MAX. W/C, 4"-5" SLUMP <br />FOOTINGS <br />4000 PSI 28-DAY COMPRESSIVE STRENGTH, NORMAL WEIGHT, <br />MAXIMUM AGGRETGATE SIZE OF 1", 0.55 MAX. W.C, 3" 4" SLUMP <br />C. CONCRETE COVER OVER REINFORCEMENT: <br />FOOTINGS <br />3" <br />SLABS COLUMNS AND BEAMS EXPOSED TO EARTH OR WEATHER <br />2" (#6 TO #18 BARS), 1 1/2" (3# TO #5 BARS) <br />SLABS NOT EXPOSED TO EARTH OR WEATHER <br />3/4" (#3 TO #11 BARS) <br />BEAMS AND COLUMNS NOT EXPOSED TO EARTH OR WEATHER <br />1 1/2" (#3 TO #18 BARS) <br />D. REINFORCING UNLESS OTHERWISE NOTED <br />S O ED (U.O.N.): <br />1. REINFORCING BARS SHALL CONFORM TO ASTM A615, GRADE 60. <br />2. WELDED WIRE FABRIC SHALL CONFORM TO ASTMA185. WIRE FABRIC SHALL <br />BE CONTINUOUS, LAPPED ONE CROSS WIRE SPACING PLUS 2" MIN. <br />3. WHERE CONTINUOUS REINFORCING IS SPECIFIED, SUCH REINFORCING MAY <br />BE SPLICED WHERE APPROVED IN WRITTING BY THE ENGINEER OF RECORDS. <br />4. AT CHANGES IN DIRECTION OF CONCRETE WALLS, BEAMS, AND FOOTINGS, <br />PROVIDE CORNER BARS OF SAME SIZE, QUANTITY AND SPACING AS <br />HORIZONTAL STEEL. <br />E. CONTRACTOR SHALL EMPLOY A 3rd PARTY TESTING & INSPECTION AGENCY <br />RETAINED BY WAWA. G.C. TO COORDINATE ALL TESTING & INSPECTIONS. AGENCY <br />SHALL PREPARE ONE SET OF FOUR TEST CYLINDERS PER DAY OR ONE SET FOR <br />EACH 50 CUBIC YARDS POURED, MAXIMUM. LABORATORY REPORT SHALL BE <br />FURNISHED TO THE STRUCTURAL ENGINEER SHOWING STRENGTH OF <br />CONCRETE AT 7 (1 CYLINDER) AND 28 (2 CYLINDERS) DAYS. FINAL CYLINDER <br />SHALL BE HELD IN RESERVE. <br />F. THERE SHALL BE NO HORIZONTAL JOINTS IN ANY CONCRETE POURS UNLESS <br />SHOWN ON THE STRUCTURAL DRAWINGS. THE ENGINEER OF RECORD SHALL <br />APPROVE ALL DEVIATIONS OR ADDITIONAL JOINTS IN WRITING. <br />G. SAW CUT CONTROL JOINTS SHALL BE LOCATED @ 12' O.G. MAXIMUM, U.O.N. WITH <br />LENGTH TO WIDTH RATIO NOT TO EXCEED 1.5:1. (INDICATED ON PLAN) JOINTS IN <br />TERRAZO FINISH FLOOR MUST ALIGN WITH CONCRETE CONTROL JOINTS. <br />H. FINISH CONCRETE SLAB ON GRADE SURFACE TO THE FOLLOWING TOLERANCES, <br />ACCORDING TO ASTM E 1155: SPECIFIED OVERALL VALUES OF FLOOR FLATNESS, <br />F(F) 20, MINIMUM LOCAL VALUES OF FLOOR FLATNESS, F(F) 15, SPECIFIED <br />OVERALL VALUES OF FLOOR LEVELNESS, F(L) 15, MINIMUM LOCAL VALUES OF <br />FLOOR LEVELNESS, F(L) 10. <br />I. LIQUID MEMBRANE FORMING CURING COMPOUNDS ARE PROHIBITED FROM USE <br />ON THE BUILDING SLAB ON GRADE AS THEY MAY ADVERSELY AFFECT THE <br />PERFORMANCE OF THE CONCRETE TERRAZO TOPPING. PROVIDE FOR CURING <br />OF THE SLAB VIA ALTERNATE OR TRADITIONAL METHODS. REFER TO ACI 308.1 <br />FOR ADDITIONAL INFORMATION. <br />J. ALL EPDXY ANCHORS USED AT REINFORCED CONCRETE SHALL BE HILT[ HIT WY <br />150 OR HIT HY 200, U.O.N. <br />K. POWDER ACTUATED FASTNERS (PAFS) NOT PERMITTED AT CONCRETE. <br />CONCRETE MASONRY UNITS (CMU) <br />A. ALL MASONRY WORK SHALL CONFORM TO ACI SPECFICATIONS FOR MASONRY <br />STRUCTURES (ACI 530). <br />B. CONCRETE BLOCK SHALL CONFORM TO ASTM C90, TYPE 11, WITH A MIN. NET <br />COMPRESSIVE STRENGTH AT 28-DAYS OF 1900 PSI (F'M = 1500 PSI). NORMAL <br />WEIGHT UNITS U.O.N. <br />C. BELOW GRADE, MORTAR SHALL BE TYPE M. ABOVE GRADE, M OR S. GROUT TO <br />CONFORM TO ASTM C270. <br />D. ALL MASONRY LOCATED BELOW GRADE SHALL BE GROUTED SOLID. <br />E. GROUT FOR FILLED CELLS SHALL CONFORM TO ASTM C476, AND SHALL HAVE A <br />SLUMP OF BETWEEN 8" AND 10". GROUT COMPRESSIVE STRENGTH SHALL BE <br />3000 PSI AT 28 DAYS. ALL GROUTING SHALL BE LOW LIFT. MAXIMUN GROUT POUR <br />HEIGHT = 5'-0". <br />F. PLACE ALL MASONRY IN RUNNING BOND WITH 3/8" MORTAR JOINTS. PROVIDE <br />COMPLETE COVERAGE FACE SHELL MORTAR BEDDING, HORIZONTAL AND <br />VERTICAL. PROVIDE FULL MORTAR WEBS IN ALL COURSE OF GROUTED CELLS <br />AND CELLS ADJACENT TO GROUTED CELLS. <br />G. PROVIDE 8" DEEP PRECAST CONCRETE REINFORCED N CO C LINTELS OVER <br />R ALL MASONRY <br />OPENINGS NOT SHOWN TO HAVE A STRUCTURAL BEAM. MINIMUM END BEARING <br />SHALL BE 8". LINTEL WIDTH TO MATCH MASONRY WIDTH. <br />H. ALL EPDXY ANCHORS USED IN MASONRY SHALL OCCUR AT GROUTED, <br />REINFORCED CELLS. <br />J. REINFORCING, UNLESS OTHERWISE NOTED IN PLANS: <br />1. REINFORCING BARS SHALL CONFORM TO ASTM A615, GRADE 60. <br />2. ALL OPENINGS IN CMU SHALL BE REINFORCED WITH AT LEAST (1) #5 BAR AT <br />THE TOP, BOTTOM AND BOTH SIDES OF THE OPENING <br />3. BOND BEAM AT ROOF LEVEL SHALL BE DOUBLE COURSE K.O. / LINTEL <br />BLOCK WITH (2) #5 CONT. BARS EACH COURSE, AND BOND BEAM AT <br />PARAPET LEVEL SHALL BE SINGLE COURSE K.O. / LINTEL BLOCK WITH (2) #5 <br />CONT. BARS. <br />4. LAP SPLICES SHALL BE AS FOLLOWS: <br />48 X BAR DIAMETERS, U.O.N. <br />5. HORIZONTAL WALL REINFORCING SHALL BE 9 GA. GALVANIZED LADDER <br />TYPE @16" O.C. VERT. <br />6. ALL REINFORCING HOOKS AND BENDS SHALL BE STANDARD ACI TYPE. <br />7. ALL WALL DOWELS SHALL MATCH REINFORCING SIZE AND QTY. <br />L. POWER ACTUATED FASTENERS (PAFS) NOT PERMITTED AT MASONRY. <br />._ .• :--._.,.:._;. ,IBC _._ <br />aav�a.�aaaaa��a��aaaaaavv�aa�a�aaaaa�aaati\���a�aama�aa� �`�a�aa\anrma�\r�aa�,t��vtota�aaa� <br />.27 : <br />Al <br />_ -- <br />a_ <br />- - - = ------ <br />Z 3 __gipp..__------------------ Z._----- <br />i.--------------------- <br />__�a` <br />_.: ,c <br />STRUCTURALSTEEL <br />A. ALL WORK SHALL CONFORM TO AISC SPECIFICATIONS FOR STRUCTURAL <br />STEEL BUILDINGS (AISC 360). <br />B. MATERIAL SHALL CONFORM TO THE FOLLOWING, EXCEPT AS NOTED: <br />W SECTIONS ASTM A992 <br />STRUCTURAL STEEL PLATES, ANGLES, CHANNELS ASTM A36 <br />THREADED ROD ANCHOR BOLTS ASTM F1554 GRADE 55-Sl <br />HEADED ANCHOR BOLTS ASTM F1554 GRADE 55-Sl <br />PIPE SECTIONS ASTM A53, GRADE B. <br />TUBE SECTIONS ASTM A500, GRADE B. <br />C. WELDING, UNLESS OTHERWISE NOTED (U.O.N.): <br />1. ALL SHOP AND FIELD WELDING SHALL CONFORM TO AWS STRUCTURAL <br />WELDING CODE, ANSI/AWS D1.1 <br />2. ALL WELDING IN THE SHOP AND IN THE FIELD SHALL BE PERFORMED BY <br />CERTIFIED WELDERS ONLY. <br />3. WELDING ELECTRODES SHALL BE E70XX LOW HYDROGEN. <br />D. CONNECTIONS, UNLESS OTHER WISE NOTED (U.O.N.): <br />1. TIGHTEN BOLTS BY THE "SNUG -TIGHT" METHOD. <br />2. FIELD CONNECTIONS SHALL BE MADE WITH 3/4" DIA. MIN. HIGH -STRENGTH <br />BEARING TYPE BOLTS (A325N) WITH THREADS ASSUMED TO BE INCLUDED <br />IN SHEAR PLANES. <br />3. ALL BEAM TO BEAM AND BEAM TO COLUMN CONNECTIONS SHALL <br />INCORPORATE THE MAXIMUM PERMISSIBLE 3/4" A325N BOLTS IN A SINGLE <br />ROW BASED ON AVAILABLE WEB DEPTH. <br />4. CONNECTIONS SHALL BE SINGLE PLATE TYPE, U.O.N. ANGLE AND EXTENDED <br />PLATE CONNECTIONS SHALL NOT BE PERMITTED UNLESS SPECIFICALLY <br />DETAILED AS SUCH HEREIN. <br />E. SHOP DRAWINGS (SEE SUBMITTALS) SHALL INCLUDE COMPLETE DETAILING OF <br />STRUCTURAL STEEL MEMBERS AND CONNECTIONS AS REQUIRED TO <br />FABRICATE AND ERECT ALL STRUCTURAL STEEL FRAMING. <br />F. GROUT UNDER BEARING PLATES SHALL BE NON-METALLIC, NON -SHRINK TYPE <br />WITH A COMPRESSIVE STRENGTH OF AT LEAST 6000 PSI WHEN BEARING ON <br />3000 PSI CONCRETE AND 8000 PSI WHEN BEARING ON 4000 PSI CONCRETE. <br />G. ALL STEEL EXPOSED TO WEATHER SHALL BE HOT -DIP GALVANIZED OR <br />OTHERWISE PROTECTED. <br />H. ALL STEEL EXPOSED TO SOIL SHALL BE ENCASED IN CONCRETE OR <br />COATED PER ASPHALIC BASED CORROSION NOTE. <br />STEEL JOISTS AND STEEL GIRDERS <br />A. ALL STEEL JOISTS, JOIST GIRDERS AND ASSOCIATED PARTS SHALL CONFORM TO <br />THE STANDARDS OF THE STEEL JOIST INSTITUTE. <br />B. ALL JOISTS AND GIRDERS SHOWN IN THE PLANS ARE MINIMUM SIZES. DEPTH <br />CANNOT BE DECREASED OR INCREASED WITHOUT WRITTEN APPROVAL BY <br />ARCHITECT/ENGINEER. <br />C. CONTRACTOR TO FOLLOW SJI REQUIREMENTS AS A MINIMUM. <br />D. PROVIDE BRIDGING AND X-BRACING AS PER THE REQUIREMENTS OF SJI. SHOULD <br />PLANS INDICATE BRIDGING AND X-BRACING IN EXCESS OF THAT REQUIRED BY SJI, <br />PLANS WILL GOVERN. <br />E. PROVIDE SEATS, HEADER CHORD EXTENTIONS, OR OTHER ELEMENTS AND <br />FEATURES SHOWN IN THE CONTRACT DOCUMENTS AND THOSE WHICH ARE <br />REQUIRED FOR PROPER ERECTION AND PERFORMANCE OF STEEL JOISTS. <br />F. STEEL JOISTS, JOIST GIRDERS, BRIDGING AND X-BRACING SHALL BE DESIGNED <br />FOR NET UPLIFT. NET UPLIFT, IN NOT PRESENTED IN PLANS SHALL BE BASED ON <br />THE CLADDING AND COMPONENTS WIND LOADS INDICATED IN THE PLANS PER <br />APPLICABLE ZONE AND TRIB AREA. LO <br />AD COMBINATIONS SHALL CONFORM T O O <br />THE CODES SPECIFIED IN THE PROJECT DOCUMENTS. <br />G. REF. PLANS FOR CONCENTRATED LOADS AND/OR UNUSUAL LOAD PATTERNS. <br />H. AT A MINIMUM, PROVIDE BOTTOM CHORD BRACING EVERY OTHER JOIST AT <br />JOIST -GIRDERS AND SUPPORTING W BEAMS. PROVIDE ADDITIONAL BRACING AS <br />SPECIFIED HEREIN AS TYPICAL AND AS INDICATED IN PLANS. <br />L MINIMUM WELDS, U.O.N.: <br />1. BAR JOIST ENDS 3/16" FILLET. 2" LONG. EACH SIDE <br />2. JOIST GIRDER ENDS 1/4" FILLET, 3" LONG. EACH SIDE <br />J. DIAGONAL BRIDGING / BRACING SHALL BE BETWEEN ADJACENT JOISTS WHENEVER <br />BOTTOM CHORD HORIZONTAL BRIDGING IS DISCONTINUOUS. <br />STEEL DECK NOTES <br />A. DECK SHALL CONFORM TO SDI SPECIFICATIONS. <br />B. SPECIFICATION AND FASTENING REQUIREMENTS, REF. PLANS <br />C. WELD METAL SHALL PENETRATE ALL LAYERS OF DECK MATERIAL. END LAPS <br />AND SIDE JOINTS SHALL BE COMPLETELY FUSED TO THE SUPPORTING MEMBERS. <br />USE PROPER SIZE WELDING ELECTRODE AND WELDING MACHINE CURRENT, SO <br />THAT WELDS ARE ADEQUATE PENETRATION AND FREE FROM "BURN -THROUGH". <br />D. METAL DECK SHALL BE ERECTED CONTINUOUS FOR A MINIMUM OF THREE (3) <br />SPANS AND SHALL LAP AT THE CENTERLINE OF SUPPORTS A MINIMUM OF TWO <br />(2") INCHES. PROVIDE A MINIMUM END BEARING OF 2" OVER SUPPORTS. <br />E. PROVIDE SUPPORTS FOR METAL DECK AS REQUIRED WHERE METAL DECK IS <br />CUT OUT. WELD DECK TO SUPPORTS SAME AS EDGE CONDITION. <br />F. DO NOT HANG OR ATTACH DUCTWORK, CONDUIT, PIPING, EQUIPMENT, CEILINGS, <br />ETC. FROM METAL DECKING. <br />G. PROVIDE STL. SHIMS AND EMBEDS AS REQUIRED TO SUPPORT DECK ON <br />"TYPICAL" BAY SPACING. <br />ASPHALTIC BASED CORROSION RESISTANCE COATING <br />A. REFER TO SPECIFICATIONS FOR GENERAL REQUIREMENTS, PRODUCTS, AND <br />EXECUTION OF WORK. <br />B. ASPHALTIC BASED CORROSION RESISTANCE COATING SHALL BE MADE WITH <br />AN ASPHALT -BASE EMULSION COATING SYSTEM PER ASTM D 1187. <br />C. APPLY A MINIMUM 1/16-INCH THICK COATING IN TWO APPLICATIONS. <br />f D. COATING TO BE APPLIED ON ALL SIDES OF MEMBERS - TO INCLUDE STEEL TO <br />BE ADJACENT TO CAST -IN -PLACE CONCRETE. <br />E. COAT STRUCTURAL, ANCHOR BOLTS, WELDS, AND ALL COMPONENTS IN THE <br />EFFECTED AND DEFINED AREA. <br />F. ALL STEEL AND STEEL COMPONENTS (I.E., BASE PLATES AND ANCHOR BOLTS) <br />EXPOSED TO SOIL SHALL BE COATED FROM THE FOUNDATION (LOWEST <br />LEVEL) UP TO 6-INCHES ABOVE THE SLAB OR FINAL GRADE - WHICHEVER IS <br />GREATER. <br />STRUCTURAL PLYWOOD / CDX <br />5/8" MIN. THICKNESS & DENSGLASS <br />(REF. ARCH.) <br />-ZONES 1, 2, AND 4 (REF. S1) #10 <br />BUGLEHEAD SCREWS @ 4" O.C. <br />EDGES AND 6" FIELD <br />-ZONES 3, AND 5 (REF. S1) #10 <br />BUGLEHEAD SCREWS @ 4" O.C. <br />EDGES AND 4" FIELD <br />Sheathing Fastener Requirementsl <br />LIGHT GAUGE FRAMING. TRUSSES & SYSTEMS <br />A. ALL LIGHT GAUGE STEEL FRAMING SHALL CONFORM TO THE <br />"SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED STRUCTURAL STEEL <br />MEMBERS," AISI." <br />B. ALL STUDS SHALL BE EQUAL TO A MINIMUM OF 6-INCH 54 MIL THICK, U.O.N. <br />C. ALL STUDS SHALL BE "C" SHAPE, U.O.N. <br />D. MATERIALS, U.O.N.: <br />54,68 AND 97 MIL STUDS 50 KSI <br />27, 33, AND 43 MIL STUDS 33 KSI <br />RUNNERS AND ACCESSORIES 33 KSI <br />E. RIGID CLIP ANGLES SHALL BE COLD FORMED TO SHAPE FROM SHEET STEEL IN <br />COMPLIANCE WITH THE REQUIREMENTS OF ASTM A653/ A653M WITH <br />STRUCTURAL STEEL (SS) GRADE 50 CLASS 1 FOR MEMBERS WITH A DESIGN <br />THICKNESS OF 0.0566 (16G) OR GREATER. <br />F. ALL PARTS AND ACCESSORIES SHALL BE FORMED FROM STEEL HAVING A G-60 <br />GALVANIZED COATING MEETING THE REQUIREMENTS OF ASTM A525 / ASTM <br />A653. <br />G. ALL FRAMING SCREWS SHALL BE A MINIMUM OF #10-16 DIAMETER EXCEPT <br />WHERE LARGER SCREWS ARE NOTED AND SHALL BE SELF -DRILLING TAPPING <br />SCREWS CONFORMING TO SAE J78. A MINIMUM OF THREE EXPOSED THREADS <br />SHALL EXTEND THROUGH THE STEEL BEYOND ALL FRAMING COMPONENTS <br />CONNECTED. SCREWS SHALL PENETRATE THE INDIVIDUAL FRAMING <br />COMPONENTS OR CONNECTION MATERIAL WITHOUT CAUSING PERMANENT <br />SEPARATION BETWEEN COMPONENTS. SCREWS SHALL BE INSTALLED SUCH <br />THAT NEITHER THREADS NOR HOLES ARE STRIPPED. ALL FRAMING SCREWS <br />SHALL BE GRABBER HEX HEAD SELF DRILLING TAPING SCREWS OR ITW <br />BUILDEX TEKS SELF DRILLING TAPING SCREWS. HILTI KWIK-PRO SELF DRILLING <br />SCREWS ARE ALSO ACCEPTABLE. SCREW DRILLING POINT ACCORDING TO <br />MANUFACTURER SPECIFICATIONS, UNLESS NOTED OTHERWISE ON DRAWINGS. <br />ALL SCREWS SHALL HAVE A CORROSION RESISTANT COATING ACCORDING TO <br />THE PROJECT SPECIFICATION. <br />H. WELDING OF LIGHT -GAUGE STEEL MEMBERS SHALL CONFORM TO THE <br />REQUIREMENTS OF AWS D1.3: STRUCTURAL WELDING CODE - SHEET STEEL. <br />WELDERS AND WELDING PROCEDURES SHALL BE QUALIFIED AS SPECIFIED IN <br />AWS D1.3. ALL WELDS SHALL BE TOUCHED -UP USING A ZINC -ENRICHED PAINT. <br />WELDING ELECTRODES SHALL BE E60XX U.N.O. DO NOT BURN THROUGH <br />MEMBERS. MEMBERS WITH DAMAGE RELATED TO WELDING SHALL BE <br />REPLACED AND NOT RE -USED, UNLESS OTHERWISE APPROVED IN WRITING BY <br />BOWEN ENGINEERING CORPORATION. <br />I. ALL STUDS SHEATHED TO BOTH SIDES SHALL HAVE LATERAL BRACING AT 4'-0" <br />ON CENTER (VERT.) MAXIMUM. REFER TO 7/S10. ALL STUDS SHEATHED ONLY ON <br />ONE SIDE OR LESS SHALL HAVE FULL DEPTH BLOCKING AT 4'-0" ON CENTER. <br />J. SPLICING OF STUDS, TRACKS AND OTHERS STRUCTURAL MEMBERS SHALL <br />NOT BE PERFORMED WITHOUT AN APPROVED SPLICE DESIGN AND DETAIL. <br />K. COPING, CUTTING OR NOTCHING OF FLANGES AND EDGE STIFFENERS IS NOT <br />PERMITTED FOR STRUCTURAL MEMBERS WITHOUT AN APPROVED DESIGN <br />AND DETAIL. <br />L. TRUSS DELIVERY, HANDLING, BRACING AND INSTALLATION BY AISI S214-07. <br />M. TRUSS SYSTEM <br />TOP CHORD DEAD LOAD: 15 PSF <br />BOTTOM CHORD DEAD LOAD: 5 PSF <br />N. LIGHT GAUGE FRAMING SYSTEMS INCLUDING TR <br />USS SYSTEMS SHALL INCLUDE <br />ALL NECESSARY PARTS AND ACCESORIES, TEMPORARY AND PERMANENT, AS <br />REQUIRED TO FORM A COMPLETE SYSTEM, INCLUDING ANCHORAGES TO <br />SUPPORT STRUCTURE. <br />STRUCTURAL INSPECTION <br />A. THE CONTRACTOR OR OWNER SHALL EMPLOY A QUALIFIED INDEPENDENT <br />INSPECTION AGENCY. THIS AGENCY (REFERRED TO AS INSPECTOR HEREIN) <br />SHALL BE RESPONSIBLE FOR VERIFYING THAT PROJECT STRUCTURAL WORK IS <br />ACCOMPLISHED IN CONFORMANCE WITH THE CONTACT DOCUMENTS. <br />B. DURATION AND FREQUENCY OF JOB VISITS SHALL BE SUFFICIENT FOR THE <br />INSPECTOR TO STATE AT THE COMPLETION OF THE PROJECT THAT THE <br />STRUCTURAL WORK IS ACCOMPLISHED, AND ITS RELATED ELEMENTS HAVE <br />BEEN ERECTED IN ACCORDANCE WITH THE CONTACT DOCUMENTS. SPECIFIC <br />SYSTEMS TO BE INSPECTED INCLUDE: <br />FOUNDATION <br />CONCRETE (GENERAL, SLAB ON GRADE) <br />STRUCTURAL STEEL (INCLUDING JOISTS & JOIST GIRDERS) <br />METAL DECK <br />LIGHT GAUGE FRAMING (INCLUDING TRUSS SYSTEMS) <br />C. THE FOREGOING LIST IS NOT INTENDED TO BE ALL INCLUSIVE. THE INSPECTOR <br />SHALL USE HIS PROFESSIONAL JUDGEMENT AND HIS KNOWLEDGE OF THE JOB <br />SITE CONDITIONS AND THE OFFICIAL CONTRACT DOCUMENTS. THE INSPECTOR <br />WILL NOT REPLACE THE QUALITY CONTROL PERSONNEL OF THE CONTRACTOR. <br />D. THE INSPECTOR DOES NOT RELIEVE THE CONTRACTORS CONTRACTUAL OR <br />STATUTORY OBLIGATIONS. THE CONTRACTOR HAS THE SOLE RESPONSIBILITY <br />FOR ANY DEVIATIONS FROM THE OFFICAL CONTRACT DOCUMENTS. THE <br />INSPECTOR WILL NOT REPLACE THE QUALITY CONTROL PERSONNEL OF THE <br />CONTRACTOR. <br />E. ALL INSPECTION REPORTS SHALL BE FORWARD BY THE INSPECTOR TO THE <br />ENGINEER AND ARCHITECT OF RECORD. <br />M <br />NO <br />cM <br />O <br />04 <br />04 <br />O <br />cz <br />O <br />O <br />as <br />O <br />�O <br />O <br />O� <br />MO M <br />a <br />TOWER <br />(140 MPH) ALLOWABLE <br />(ASD) WIND PRESSURES (ASCE 7-10) FOR COMPONENTS AND CLADDING <br />EFFECTIVE <br />ZONE 1 <br />ZONE 2 <br />ZONE 3 <br />ZONE 4 <br />ZONE 5 <br />AREA <br />(SOFT) <br />POS. (PSF) <br />NEG. (PSF) <br />POS. (PSF) <br />NEG. (PSF) <br />POS. (PSF) <br />NEG. (PSF) <br />POS. (PSF) <br />NEG. (PSF) <br />POS. (PSF) <br />NEG. (PSF) <br />10 <br />17.1 <br />-27.2 <br />17.1 <br />-47.4 <br />17.1 <br />-70.0 <br />29.7 <br />-32.3 <br />29.7 <br />-39.8 <br />20 <br />15.6 <br />-26.4 <br />15.6 <br />-43.5 <br />15.6 <br />-65.5 <br />28.4 <br />-31.0 <br />23.4 <br />-37.1 <br />50 <br />13.7 <br />-25.5 <br />13.7 <br />-38.6 <br />13.7 <br />-59.5 <br />26.6 <br />-29.2 <br />21.6 <br />-33.6 <br />A > 100 <br />12.1 <br />-24.7 <br />12.1 <br />-34.8 <br />12.1 <br />-54.9 <br />25.3 <br />-27.8 <br />25.3 <br />-30.9 <br />NOTES: <br />1. ROOF OVERHANG PRESSURES: <br />a. ZONE 2 OR +16 PSF AND -77.1 PSF <br />b. ZONE 3 OR +16 PSF AND -100.0 PSF <br />2. "A" DENOTES EDGE STRIP = 3'- 0". <br />3. POSITIVE & NEGATIVE SIGNS SIGNIFY PRESSURES ACTING TOWARDS AND AWAY FROM THE BUILDING SURFACES, <br />RESPECTIVELY (FULL HEIGHT, U.N.O.). <br />4. WIND PRESSURES INDICATED ABOVE ARE ALLOWABLE STRESS DESIGN WIND PRESSURES. DIVIDE THE PRESSURES <br />BY A FACTOR OF 0.6 TO OBTAIN STRENGTH DESIGN WIND PRESSURES. <br />LIST OF STRUCTURAL ABBREVIATIONS <br />AB <br />ANCHOR BOLTS <br />MATL <br />MATERIAL <br />ADDL <br />ADDITIONAL <br />MAX <br />MAXIMUM <br />ALT <br />ALTERNATE <br />MB <br />MASONRY BEAM <br />ANCH <br />ANCHOR <br />MC <br />MOMENT CONNECTION <br />APPROX <br />APPROXIMATE <br />MCU <br />MASONRY COLUMN UNIT <br />ARCH <br />ARCHITECT/ARCHITECTURAL <br />MCJ <br />MASONRY CONTROL JOINT <br />BB <br />BOND BEAM <br />MECH <br />MECHANICAL <br />BLDG <br />BUILDING <br />MEZZ <br />MEZZANINE <br />BM <br />BEAM <br />MFR <br />MANUFACTURE/ <br />BO <br />BOTTOM OF <br />MANUFACTURERS <br />BOT/BTM <br />BOTTOM <br />MIN <br />MINIMUM <br />BP <br />BASE PLATE/BEARING PLATE <br />MISC <br />MISCELLANEOUS <br />BRG <br />BEARING <br />MTL <br />METAL <br />BTW <br />BETWEEN <br />NIC <br />NOT IN CONTRACT <br />CANT <br />CANTILEVER <br />NOM <br />NOMINAL <br />CB <br />CONCRETE BEAM <br />NTS <br />NOT TO SCALE <br />CC <br />CONCRETE COLUMN <br />OC <br />C ON ENTER <br />CIP <br />CAST IN PLACE <br />OPNG <br />OPENING <br />CJ <br />CONSTRUCTION JOINT <br />OPP <br />OPPOSITE <br />CL <br />CENTERLINE <br />PB <br />PARAPET BEAM (MASONRY) <br />CLR <br />CLEAR/CLEARANCE <br />PCC <br />PRECAST CONCRETE <br />COL <br />COLUMN <br />PL <br />PLATE <br />CONC <br />CONCRETE <br />PLF <br />POUNDS PER LINEAR FOOT <br />CONNX <br />CONNECTION <br />PLY <br />PLYWOOD <br />CONSTR <br />CONSTRUCTION <br />PRE-ENG <br />PRE-ENGINEERED <br />CONT <br />CONTINUOUS <br />PEMB <br />PRE-ENGINEERED METAL <br />CORR <br />CORRUGATED <br />BUILDING <br />CMU <br />CONCRETE MASONRY UNIT <br />PRE-FAB <br />PRE -FABRICATED <br />DET <br />DETAIL <br />PRELIM <br />PRELIMINARY <br />DIA/DIAM <br />DIAMETER <br />PROJ <br />PROJECTION <br />DIM <br />DIMENSION <br />PSF <br />POUNDS PER SQUARE FOOT <br />DIST <br />DISTANCE <br />PSI <br />POUNDS PER SQUARE INCH <br />DN <br />DOWN <br />PT <br />PRESSURE TREATED <br />DR <br />DRAIN <br />PT <br />POST TENSION(ING) (ED) <br />DWG <br />DRAWING <br />PW <br />PANEL WIDTH <br />DWL <br />DOWEL <br />RAID <br />RADIUS <br />EA <br />EACH <br />RB <br />ROOF BEAM (MASONRY) <br />EE <br />EACH END <br />RCP <br />REINFORCED CONCRETE PIPE <br />EF <br />EACH FACE <br />RD <br />ROOF DRAIN <br />EJ <br />EXPANSION JOINT <br />REF <br />REFERENCE <br />EL/ELEV <br />ELEVATION <br />REINF <br />REINFORCING <br />ELECT <br />ELECTRICAL <br />REQ'D <br />REQUIRED <br />EMB <br />EMBEDMENT <br />REV <br />REVISION <br />ENGR <br />ENGINEER <br />RTU <br />ROOF TOP UNIT <br />EQ <br />EQUAL <br />RW <br />RETAINING WALL <br />EQUIP <br />EQUIPMENT <br />SECT <br />SECTION <br />EQUIV <br />EQUIVALENT <br />SCH/SCHED <br />SCHEDULE <br />ES <br />EACH SIDE <br />SIM <br />SIMILAR <br />EXIST <br />EXISTING <br />SP/SPC <br />SPACE(S) <br />EXP <br />EXPANSION <br />SPECS <br />SPECIFICATIONS <br />EXT <br />EXTERIOR <br />SQ <br />SQUARE <br />EW <br />EACH WAY <br />SS <br />STAINLESS STEEL <br />FAB <br />FABRICATE <br />STD <br />STANDARD <br />FD <br />FLOOR DRAIN <br />ST/STL <br />STEEL <br />FDN <br />FOUNDATION <br />STRUC <br />STRUCTURAL <br />FF <br />FINISHED FLOOR <br />SYM <br />SYMMETRICAL <br />FIN <br />FINISH(ED) <br />T & B <br />TOP AND BOTTOM <br />FL/FLR <br />FLOOR <br />T & G <br />TONGUE AND GROOVE <br />FTG <br />FOOTING <br />TE <br />THICKENED EDGE <br />GA <br />GAGE/GUAGE <br />THK <br />THICK <br />GALV/GV <br />GALVANIZED <br />THIRD <br />THREAD(ED) <br />GC <br />GENERAL CONTRACTOR <br />TB <br />TIE BEAM <br />HAS <br />HEADED ANCHOR STUD <br />TOC <br />TOP OF CONCRETE <br />HB <br />HIGH BEAM (MASONRY) <br />TOM <br />TOP OF MASONRY <br />HORIZ <br />HORIZONTAL <br />TOS <br />TOP OF STEEL <br />HSB <br />HIGH STRENGTH BOLTS <br />TYP <br />TYPICAL <br />HSS <br />HOLLOW STEELSECTION S <br />T S <br />TUBE STEEL <br />HT <br />HEIGHT <br />UNO <br />UNLESS NOTED OTHERWISE <br />INT <br />INTERIOR <br />LION <br />UNLESS OTHERWISE NOTED <br />JST <br />JOIST <br />VERT <br />VERTICAL <br />JT <br />JOINT <br />VIF <br />VERIFY IN FIELD <br />K <br />KIPS <br />W <br />WIDE FLANGED <br />KO <br />KNOCK OUT <br />WB <br />WALL BEAM (TILT) <br />KSF <br />KIPS PER SQUARE FOOT <br />WC <br />WALL COLUMN (TILT) <br />KSI <br />KIPS PER SQUARE INCH <br />W/ <br />WITH <br />L <br />ANGLE <br />W/O <br />WITHOUT <br />LB <br />LOW BEAM (MASONRY) <br />WD <br />WOOD <br />LBS <br />POUNDS <br />WGT <br />WEIGHT <br />LID <br />DEVELOPMENT LENGTH <br />WH <br />WEEPHOLE <br />LDH <br />LONG DIMENSION HORIZONTAL <br />WP <br />WORKING POINT <br />LDV <br />LONG DIMENSION VERTICAL <br />WT <br />STEEL TEE SECTION <br />LGTH <br />LENGTH <br />WWF <br />WELDED WIRE FABRIC <br />LLBB <br />LONG LEG BACK TO BACK <br />@ <br />AT <br />LLH <br />LONG LEG HORIZONTAL <br />& <br />AND <br />LLV <br />LONG LEG VERTICAL <br />® <br />0 co <br />O <br />® <br />O <br />O <br />O <br />0 O <br />a <br />WALL PRESSURES <br />BUILDING <br />ROOF <br />PRESSURES <br />(140 MPH) ALLOWABLE <br />(ASD) WIND PRESSURES FOR COMPONENTS & CLADDING (ASCE 7-10) <br />EFFECTIVE AREA <br />ZONE 1 <br />ZONE 2 <br />ZONE <br />3 <br />ZONE 4 <br />ZONE 4 <br />PARAPET <br />ZONE 5 <br />ZONE 5 <br />PARAPET <br />(SO F) <br />PRESSURE <br />SUCTION <br />PRESSURE <br />SUCTION <br />PRESSURE <br />SUCTION <br />PRESSURE <br />SUCTION <br />CASE A <br />CASE B <br />PRESSURE <br />SUCTION <br />CASE A <br />CASE B <br />10 <br />10.8 PSF <br />-26.6 PSF <br />24.3 PSF <br />-44.6 PSF <br />24.3 PSF <br />-44.6 PSF <br />24.3 PSF <br />-26.4 PSF <br />73.0 PSF <br />53.7 PSF <br />24.3 PSF <br />-32.5 PSF <br />73.0 PSF <br />60.1 PSF <br />20 <br />10.2 PSF <br />-26.0 PSF <br />23.3 PSF <br />-39.9 PSF <br />23.3 PSF <br />-39.9 PSF <br />23.3 PSF <br />-25.3 PSF <br />23.3 PSF <br />-30.1 PSF <br />50 <br />9.6 PSF <br />-25.1 PSF <br />21.9 PSF <br />-33.6 PSF <br />21.9 PSF <br />1 -33.6 PSF <br />21.9 PSF <br />-23.9 PSF <br />21.9 PSF <br />-27.5 PSF <br />A -100 <br />9.6 PSF <br />-24.3 PSF <br />20.8 PSF <br />-28.8 PSF <br />20.8 PSF <br />T -28.8 PSF <br />20.8 PSF <br />-22.8 PSF <br />20.8 PSF <br />-25_3 PSF <br />l_ <br />NOTES: <br />1. PARAPET WIND PRESSURES: <br />CASE A = PRESSURES TOWARD THE BUILDING. <br />CASE B = PRESSURES AWAY FROM THE BUILDING. <br />2. R DENOTES PARAPET PRESSURE VALUES. <br />3. 'a' DENOTES EDGE STRIP = 6'4' <br />4. POSITIVE & NEGATIVE SIGNS SIGNIFY PRESSURES ACTING TOWARDS AND AWAY FROM THE <br />BUILDING SURFACES, RESPECTIVELY (FULL HEIGHT, UNLESS NOTED). <br />5. WIND PRESSURES INDICATED ABOVE ARE ALLOWABLE STRESS DESIGN WIND PRESSURES. <br />DIVIDE THE PRESSURES BY A FACTOR OF 0.6 TO OBTAIN STRENGTH DESIGN WIND PRESSURES <br />�k <br />co <br />Y m <br />11 <br />Q <br />Lu <br />Z <br />Q <br />0 <br />J <br />J <br />Un <br />m <br />Z <br />w a <br />� <br />cn <br />Lu <br />0- <br />Q <br />z <br />w <br />3:3: <br />v <br />3�: <br />O <br />N <br />Q <br />�1 <br />L�J <br />N <br />Lo <br />00 <br />N <br />L.LJ <br />U) <br />T <br />0 <br />T <br />N <br />>U-) <br />co <br />J <br />m co <br />0o <br />z <br />LL <br />:5J <br />Q <br />W <br />Lu <br />3: <br />06 ff <br />m <br />a <br />Q <br />T >_ <br />M <br />Lu <br />N <br />a <br />U) <br />Lu <br />0 <br />Z <br />0 <br />z <br />Q <br />Q <br />LJJ <br />CU <br />Z <br />0 <br />Lu <br />~ Lu <br />Lu QLu <br />w <br />,i1�11�feffl�j,�,;ff'' <br />1.` C <br />y <br />N 56698 rf� <br />F110"��`''''''.}}>, <br />O �kkffA el <br />�161111 lZitt <br />03/03/2017 <br />�C) <br />N <br />0 <br />c�M <br />O <br />d <br />M <br />o <br />o <br />w <br />rl <br />0 <br />z <br />C5 <br />Z <br />o <br />�n <br />oo <br />UC)Z <br />M <br />Lu <br />uj <br />p <br />he <br />cc: <br />r <br />w <br />ch <br />¢ <br />0 <br />0 <br />s <br />