Laserfiche WebLink
1 ST FLOOR HVAC PLAN <br />HVAC NOTES SYMBOLS: <br />ALL CONSTRUCTION SHALL COMPLY WITH LOCAL <br />BUILDING CODES AND THE STATE ENERGY CODE. <br />OBTAIN REQUIRED PERMITS AND INSPECTIONS. THE <br />MECHANICAL INSTALLER IS TO VERIFY ALL <br />CLEARANCES AND ACCESS SPACE BEFORE <br />FABRICATION OR INSTALLATION OF ANY HVAC WORK. <br />INSTALL WVAC EQUIPMENT PER MANUFACTURERS <br />RECOMMENDATION. DUCT BOARD EQUAL TO KNAUF 1 <br />1/2". R-6, INSTALLED PER MANUFACTURERS <br />INSTRUCTIONS. FLEXIBLE DUCT WORK EQUAL TO <br />ATCO 76, R-6, CLASS 1 AIR DUCT. SEAL ALL <br />DUCTWORK PER UL181 P. PROVIDE A FIRE STAT IN <br />THE RETURN AIR PLENUM OF ALL AIR HANDLING <br />UNITS. MOUNT THERMOSTAT 60" ABOVE FLOOR. <br />CONDENATE DRAIN LINE TO SPILL ON GRASS. G.C. <br />TO PROVIDE UNDERSLAB DRAINS, CHASES, AND AIR <br />HANDLER PLATFORMS. <br />_ EXHAUST (j _ EXHAUST FAN <br />® FAN `* + LIGHT <br />®= THERMOSTAT, MOUNTED AT 60" A.F.F <br />= LENGHT OF DUCTWORK IN FEET <br />RETURN _ TRANSFER <br />8"XNR LC�jtILL rGRILL <br />SL30SQf#LY <br />= GRILL <br />0 <br />_ AIR MIXING BOX <br />HEIGHT <br />12x17x17xHEIGHT <br />A=23" <br />G=13" <br />8=17" <br />H=12" <br />- AIR MIXING BOX <br />14x16x16x12xHEIGHT <br />D21 =" <br />J 15" <br />AIR MIXING BOX <br />E=15" <br />N=11" <br />❑_ <br />23x23xHEIGHT <br />F=15" <br />0=10" <br />K=23"x23"x23" <br />L=17"x17"x17" <br />M=13"x 13"x 13" <br />CARRIER SPLIT HEAT PUMP <br />AIR HANDLER MARK: <br />AHU <br />UNIT MODEL NUMBER: <br />FE4BNF003 <br />SUPPLY FAN CFM/SP: <br />700-1225/.4 <br />SUPPLY FAN HP: <br />1 /2 <br />UNIT VOLTAGE: <br />208/230/1/60 <br />UNIT DIMENSIONS HWD: <br />54x22x23 <br />UNIT WEIGHT: <br />150 LBS <br />HEAT STRIP KW: <br />10 <br />HEAT STRIP MCA/BRKR.: <br />58.5/60 <br />CONDENSER MARK: <br />CU <br />UNIT MODEL NUMBER: <br />25HBC336OA003 <br />UNIT VOLTAGE: <br />208/230/1/60 <br />UNIT MCA/BREAKER: <br />24.9/35 <br />UNIT DIMENSION HWD: <br />45x31x31 <br />UNIT WEIGHT: <br />225 LBS <br />TOTAL COOLING BTUH: <br />33,800 <br />SENSIBLE COOLING BTUH: <br />26,300 <br />TOTAL HEATING BTUH: <br />34,400 <br />SEER/AFUE <br />14.0/7.8 <br />ARI# <br />3698872 <br />CARRIER SPLIT FURNACE <br />AIR HANDLER MARK: <br />-- <br />UNIT MODEL NUMBER: <br />-- <br />SUPPLY FAN CFM/SP: <br />-- <br />SUPPLY FAN HP: <br />-- <br />UNIT VOLTAGE: <br />-- <br />UNIT DIMENSIONS HWD- <br />UNIT WEIGHT: <br />-- <br />HEAT STRIP KW: <br />-- <br />HEAT STRIP VOLTAGE: <br />-- <br />CONDENSER MARK: <br />-- <br />UNIT MODEL NUMBER: <br />-- <br />UNIT VOLTAGE: <br />-- <br />UNIT MCA/BREAKER: <br />-- <br />UNIT DIMENSION HWD: <br />-- <br />UNIT WEIGHT: <br />-- <br />TOTAL COOLING BTUH: <br />-- <br />SENSIBLE COOLING BTUH: <br />-- <br />TOTAL HEATING BTUH: <br />-- <br />SEER/AFUE <br />-- <br />SCALE: <br />1/8' ®1' TO 11x17 BLACKPOINT <br />1/4" - 1' w 22x34 ENABLED <br />J <br />IL <br />cr <br />w <br />U) <br />Q <br />U <br />Z <br />Q <br />>- O U J J <br />m j J J J <br />oJQQ� <br />L� Q <br />W p Z <br />(r W <br />�03 -1 <br />LE 0 j <br />❑❑❑❑❑ <br />U <br />Z <br />0 <br />(L w <br />w <br />O it <br />w <br />♦� (f) <br />V <br />c� <br />z <br />J <br />Q <br />o <br />J L Z <br />a <br />D <br />m Jcr <br />0 <br />W Q r) <br />o z <br />O = oNm <br />m <br />T � w <br />go <br />Z `` Z <br />//♦0:5 <br /><c o Z <br />J <br />Z O <br />ISSUE DATE <br />SEPTEMBER 2010 <br />DRAWN BY <br />SIMPAD <br />DESIGN BY <br />INLAND HOMES <br />REVISION DATE <br />12131110 <br />SHEET <br />HVAC PLAN <br />If <br />