Laserfiche WebLink
3 <br />v <br />x <br />W <br />fA\ <br />0 <br />i <br />m <br />0 <br />N <br />aU <br />C <br />C, <br />Q <br />LO <br />c0 <br />0 <br />J <br />8 <br />LO <br />N <br />v <br />cn <br />0 <br />Q <br />a <br />N <br />C] <br />0 <br />E <br />a� <br />E <br />0 <br />x <br />0 <br />c <br />J <br />f/q <br />a> <br />E2 <br />v <br />0 <br />U <br />16 <br />W <br />0 <br />i <br />0 <br />U <br />J <br />LLL <br />N <br />N <br />N <br />0 <br />0 <br />0 <br />CL <br />cV <br />0 <br />cV <br />N <br />v <br />a <br />Q <br />m <br />v <br />THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />3/8" CEMENT <br />PLASTER <br />12 MIL DRYLOK <br />CMU - MASONRY BLOCK <br />EXTREME <br />WINDOW <br />FASTENER <br />1) SEALANT ATWINDOW <br />4) SEALANT JOINT <br />BUCK TO <br />OUTSIDE EDGE OF <br />'' MASONRY <br />WINDOW BUCK <br />2) SEALANT JOINT <br />5) SEALANT FROM <br />INSIDE EDGE OF <br />WINDOW FRAME <br />WINDOW BUCK <br />ACROSS WINDOW BUCK <br />AND EXTEND TO <br />WINDOW FRAME <br />MASONRY <br />ATTACHED <br />PER CODE <br />6) TOOLED SEALANT <br />REQUIREMENTS <br />BEAD BRIDGING <br />CLADDING AND WINDOW <br />FRAME <br />3) SEALANT WINDOW FRAME T( <br />WINDOW BUCK ALL THE WAY <br />AROUND, INCLUDING SILL. <br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND <br />FENESTRATION INSTALLATION AND INTERFACE <br />JAMB, SILL AND HEAD DETAIL <br />APPROVED SHEATHING <br />APPROVED HOUSEWRAP <br />STRUCTALATH TWIN TRACK 2.5 <br />3/4" CEMENT PLASTER <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />"V" SEALANT SOCKET WITH <br />TOOLED APPROVED SEALANT <br />WEATHER <br />RESISITIVE <br />BARRIER <br />HEAD FLASHING TIE-IN INSTRUXTI( <br />1. Cut, fold up & temporarily secure I <br />resistive barrier above header to allow for <br />flashing installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />S <br />DO NO' <br />BOTTO <br />ci AM(, <br />FOLD UP WEATHER <br />RESISTIVE BARRIER & <br />TEMPORARILY SECURE <br />WOOD FRAME CONSTR. <br />EXTERIOR <br />SELF -ADHERED FLASHIN <br />SHEATHING <br />BY LAPPING DOWN <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />SELF-ADHEREDFLASHING <br />HALF ROUND WINDOW <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOI: <br />UNDER DECKING <br />ED FLASHING I (SEE DETAIL WP07) <br />ne� <br />4SHING <br />WEATHER RESISTIVE <br />BARRIER <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"-V BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING \ <br />1 O <br />2 SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED S:iiii <br />FLASHING F <br />SCS 0602 WINDOW FIN INTERFACE WITH <br />SELF -ADHERED FLASHING <br />EXTRUDED SHOULDER <br />DECK JOIST <br />SELF -ADHERED FLASHING <br />2x FRAMEWALL <br />PRODUCTS DETAILS <br />TILE FINISH <br />1/2" DUROCK <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instructions <br />1'-4" PER PLAN <br />Refer to the number marked asRinstructionsin each detail that corresponds to the <br />1'-0" PER PLAN <br />numbered items in the list below: <br />1. Install self -adhered flashing in order as shown by numbers <br />SLOPE <br />8" CMU <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />4" OR 8" CMU 4 a <br />3. Self -adhered flashing can be substituted for building paper <br />(PER SEAT DEPTH) <br />4. Split the release paper using the ripcord (Split release on demand, <br />FILL WITH GROUT a <br />embedded in the adhesive layer) - for ease of installation and to <br />° <br />minimize scoring cuts <br />a ° ° <br />5. Remove all release paper per standard installation instructions and <br />a a <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />° <br />Minimum) <br />SLOPED MUD BED ° <br />6. Fold as shown by arrows <br />a a <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />° <br />VINYL SHOWER PAN - a ° <br />8. Mechanically fasten as necessary <br />e <br />SLOPEEfl <br />a ° <br />a a <br />Q <br />SHOWER SEAT <br />J <br />In <br />SELF-ADHER <br />:: <br />u <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />WINDOW UNIT FLASHING REQUIREMENTS <br />�- DOOR ROUGH OPENING <br />SLOPE <br />0.3 in : 12.0 in R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />- 3/4"-1" BEAD OF CONSTR. (0.6 cm: 30.5 cm) include flashing as described in Section R703.4. <br />ADHESIVE TO BE APPLIED UNDER SELF -ADHERED FLASHING <br />THRESHOLD OF DOOR AND <br />RETURN UP JAMB 6". USE LIQUID R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of <br />NAIL BRAND OR EQUAL WEATHER EXTERIOR <br />PROOF CAULKING CEMT. FIN. water within the wall assembly by providing awater-resistant barrier behind the exterior cladding as required by Section R703.2 and a means <br />SELF -ADHERED FLASHING BUILDING PAPER of draining to the exterior water that penetrates the exterior cladding. <br />WIRE LATH R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or <br />SUBFLOOR other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied <br />= horizontally, with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The <br />RIM JOIST No.15 asphalt felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and <br />building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />1 R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over <br />wood -based sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade <br />2 D paper. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER AN <br />Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT substantially nonwater-absorbing layer or designed drainage space. <br />RUBBERIZED <br />INSTALL SELF -ADHERED NEEDED IN CORNERS ASPHALT ADHESIVE ADHESIVE <br />FLASHING JAMB&HEAD THROUGH SELF -ADHERED R703.4 Flashing. Approved metal flashing, vinyl flashing, self -adhered membranes and mechanically attached flexible flashing shall be <br />FLASHING, SEE FLASHING SELF -ADHERED FLASHING applied shingle -fashion or in accordance with the manufacturer's instructions. Metal flashing shall be corrosion resistant. Fluid -applied <br />FLANGED WINDOW pp 9 g pp <br />(SEE DETAIL WP01) membranes used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to <br />SCORED prevent the entry of water into the wall cavity or penetration of water to the building structural framing components. <br />RELEASE PAPER Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />SELF -ADHERED FLASHING, ` �� (BEFORE FOLDING, SCORE the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />EXTEND A MINIMUM 6" READ ADHESIVE LEASE PAPER TO contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />BOTTOM OF FROM flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />THRESHOLD shall be installed at the following locations: <br />1.1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />2 shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following: <br />5 1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />4 manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details <br />1 6 are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for <br />2 7 subsequent drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />SELF -ADHERED FLASHING 1,3 1.3. In accordance with other approved methods. <br />' INSIDE CORNER , 1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />Ground 3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4.Conti nuously above all projecting wood trim. <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />`c 1 6, 6.At wall and roof intersections. <br />water Resistant Barrier 7.7.At built-in qutters. <br />:LF-ADHERED FLASHING <br />,TCH <br />HERED FLASHING <br />2 <br />14 <br />5 <br />1 <br />a <br />FOUNDATION WEEP SCREED <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2" INCH FLANGE <br />PLASTER STOP THIS <br />NATU <br />DO N, <br />CONTINUOUS BACKER <br />ROD & SEALANT DRIP <br />ACCE <br />A <br />SOFFIT/CANTILEVER <br />Lath <br />Sheathing <br />Stucco <br />LEGEND <br />SELF ADHERED FLASHING (SAF) ti <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) <br />BOND BREAK WEATHER RESISTANT BARRIER - <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY <br />SHEATHING, 'OSB', PLYWOOD, DENSGLASS <br />FRAMING <br />SHEATHING <br />ANE WRB <br />WRB <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />- Felt backed metal <br />lathe in accordance <br />with ASTM C1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />- Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />/,00-.. <br />e <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />.Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked' using <br />Stampede or sim. <br />caulk for all <br />i <br />cc <br />kcD <br />w� <br />v <br />014 <br />CP- � <br />CD <br />i" <br />M <br />CV <br />O <br />CV <br />CV <br />O <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />U) <br />W <br />�4 <br />E <br />Q <br />U <br />0 <br />O <br />tlf <br />Q <br />M0 <br />C J LL <br />W <br />JLLiL a. <br />Z <br />CILN <br />-DO' a <br />m c d. <br />a120 <br />r.- N,p 0 O <br />Wr°�a'°' <br />�. <br />m <br />Cl) Z <br />Z <br />o <br />W <br />❑❑ <br />0 0 <br />C N <br />z o <br />d <br />J <br />u � I1 <br />M <br />z �O <br />CD O <br />4--J <br />Fu <br />w <br />o <br />O <br />V) <br />�V) <br />c w <br />U) <br />U <br />L U <br />P li" <br />U o S <br />U <br />Q N O <br />-D <br />r <br />o <br />w <br />M <br />J <br />� � <br />Z <br />Z <br />LL <br />a o <br />E U <br />w <br />a o <br />wz <br />Z <br />zo <br />oa <br />F� (O <br />OQ <br />Do <br />U <br />O E <br />co <br />Z <br />�o�J <br />co <br />ao <br />mo <br />�w <br />-j <br />¢� <br />�z <br />3 <br />go <br />(n <br />� <br />a <br />w w <br />m w <br />=K <br />C0 <br />Jz <br />3 <br />c� <br />.o <br />o <br />v <br />w< <br />0l <br />$ <br />0 O <br />= <br />> (,� <br />IX <br />.. <br />O <br />°i <br />N <br />0 <br />LO <br />(.0 <br />00 <br />^ <br />O <br />(Cr m <br />N <br />LO <br />d' <br />M <br />O <br />Co <br />O <br />N N <br />LO <br />N <br />Q <br />M N <br />r <br />cfl <br />E <br />Li / <br />M <br />Z <br />(a <br />z <br />:3 <br />E N <br />f� r <br />m <br />ro <br />e <br />JOB <br />NO: <br />23-00504 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />WP1 <br />i I 1: 7L I I, -- - - -----T-. i i : , .III I I i.1.�.dhiihll :hi.. is - n,ii°I 111hill I I I i I I I <br />