My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
36419 Flats St
Zephyrhills
>
Building Department
>
Building Plans
>
36419 Flats St
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 10:31:24 AM
Creation date
2/19/2025 12:41:00 PM
Metadata
Fields
Template:
Building Plans
Street #
36419
Location
Flats St
Contractor
Lennar Homes LLC
Building Plans - Permit #
6210
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />WALL SHEATHING <br />{ CE: <br />I —�1� ......... . <br />`:::f.:..:.:.. <br />16GAxl-1\2" LONG (3/4"-1" CROWN 5'::::::::::.:.:.:.:.:.:::.::.:.:.:.:.::::::::. .... <br />MAX.. <br />STAPLES @ 6," O.C. VERT BETWEEN ..........:.. _ .... I 16GAxl-1/2" LONG (3/4"-1" <br />STUDS (NOTED THUS:-) - OFFSET CROWN) STAPLES @ 6" <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />4__ <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />`DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />10"-0" <br />TANK -LESS W/H <br />H C G <br />O O O <br />01 5'-0" _ <br />STUB -OUT FOR O o _1GAS METER _ L)LO <br />CV oz <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6A <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3) 16d TOENAILS <br />2" X 12" @ 24" O.C. <br />154" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" or 718" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 314" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 314" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking ° <br />x <br />gap <br />07 <br />w <br />CONT. #5 <br />BAR -� <br />FILL CELL <br />STD. 90° <br />HOOK <br />STD. 90' HOOK r- BOND BEAM <br />SIMPSC <br />w/ (22)10d <br />NAILS TYP. GIRDER TRUSS <br />- CONT. #5 <br />BAR 2X TOP PLATE <br />5/81 <br />#5 CONT. THRU <br />FROM BOLT <br />FOUNDATION TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D PLYWOOD FLOOR <br />COLUMN AND SHEATHING PER PLAN <br />CONNECTION TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @INT. BRG. WALL <br />N.T.S. <br />1/8" min. 2" min. <br />2„ Small gap }„ <br />max. � 4 max. <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web flan connection. <br />web -flange o <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2" min. <br />required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING %" GAP @TOP sides by 6". - Hangers with sides not containing t. WEB STIFFENER <br />DOUBLE JOIST CONNECTION topflanguthe ofcuts. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor Cnlr rmn w/ In;0_q <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />i/16" <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Load bearing walls -7 <br />higher than 15001b <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max, along bearing wall <br />Required on interior walls : for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* —� <br />Web Stiffener Fastener Schedule <br />Joist Bearin Location <br />Series De th End Intermediate <br />BCI5000s® <br />9-112" <br />2-8d <br />2-8d <br />11-718" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5- d <br />BCI 6000se <br />BC16500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BC190s® <br />11-7/8" <br />3-16d <br />3-16d <br />14 <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />1.0 <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />Plumbing META12 TSS INSTALLATION <br />Joist <br />When joists meet over wail, provide <br />1-1 3/4" minimum bearing for each. I -Joist can be offset <br />"" <br />up to 3 to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />k�� <br />Provide adequate bearing <br />for each lapped joist. Use 10dxT nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />Squash block) 10d nails SECTION INT. BRG. WALL require additional consideration. <br />2x4 minimum <br />Bearing wall, Versa -Lam LVL or N.T.S. <br />Glulam Beam <br />MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch Joist hanger <br />or drill flanges <br />6"" A 1 2" ROUND HOLE MAY 6"" 6"" DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Y2" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS, <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1%2' <br />Any 16"joist <br />8 <br />11-91 <br />1'-1" <br />11-21 <br />1l 2" <br />1 T-3' <br />1'-3" <br />1'-7" <br />1'-11 • <br />Z 4" <br />3, 2 <br />12 <br />T-9' <br />1,-1", <br />1"-2. <br />1-2". <br />1, 3. <br />1'-9 <br />2-4" <br />2-11" <br />37"' <br />42" <br />4'-9" <br />6-4' <br />10 <br />1"-0 <br />1"_11. <br />1' <br />1 2,. <br />1' 7" <br />3'-2" <br />3-10'° <br />4- <br />6T''- <br />7-21 <br />20 <br />!' C) <br />1'-1" <br />1' 2" <br />1'2'" <br />2'-0" <br />3'-0" <br />4' -Q" <br />4"-10'" <br />6-11'" <br />6a 11" <br />71„ <br />' 1 <br />S'-11" <br />24 <br />1'-U' <br />T-1" <br />1' 2" <br />T3" <br />2-6' <br />377' <br />4-7 <br />6-11Y' <br />7' 2" <br />8-4." <br />9-6' <br />10' 9' <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY, <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT, <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) — <br />Nail with 10-10d nails. =1 I I={ I I=1(( 1= T�• <br />Install tight to top flange. SLEEVE THRU STEM d A. ' . <br />a. c <br />SEE PLAN FOR °• ° . • <br />FOUNDATION INFO a. a <br />STEM FOUNDATION <br />y \ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />'Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />p depth <br />I -JOISTS BUCKETS <br />N.T.S <br />GRADE <br />a <br />r-REINF. SEE PLAN <br />�A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />/r_ <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />co Z • ° • <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />d <br />A <br />v ° a <br />a a <br />a <br />-r B r <br />Q <br />SEE FND. PLN. <br />SIZE & REINF. <br />m <br />cam, <br />c® <br />0 <br />o <br />L <br />C <br />A C= <br />0- <br />CO ® i <br />y: N -� <br />COV <br />3='dam <br />_d <br />�. <br />�, C, ._ <br />� 3 <br />�o <br />a C, <br />M <br />CV <br />0 <br />CV <br />0 <br />OriS{f6rG;lg41! <br />,r` <br />`e EPd"`q <br />-.0. STATE OF <br />♦ 0re '"...... <br />.1 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />W <br />Q <br />N <br />'I E10 <br />O R O N 4 <br />N CD # <br />O C � � <br />0 <br />ao <br />N <br />M <br />rnrZ LL w <br />0. a <br />Q <br />t7 <br />0aW� <br />ajrNiv o W <br />co_ U d C7 <br />'i-5 o@Mo <br />a <br />v <br />oowF <br />O_ <br />_ <br />IL <br />z <br />Z<N M <br />❑z <br />❑O ❑o <br />OC) <br />z N O <br />— � o <br />� N <br />z o � <br />J — <br />r <br />N <br />z <br />l <br />4-1 <br />C!3 <br />W m <br />� <br />V <br />O—� <br />un <br />W o <br />U 6 <br />e <br />U ) <br />w <br />ti <br />o <br />�< <br />w <br />M <br />� � <br />z <br />Q <br />E <br />�o <br /><� <br />E O <br />of <br />oa <br />N <br />CL F 6 <br />¢ � <br />�o <br />()o <br />� <br />o E <br />�< <br />ao <br />oz <br />�Z <br />z <br />a <br />ao <br />�W <br />C/� <br />z <br />'2 <br />mO <br />zz <br />z <br />m <br />°� m <br />'< w <br />3 <br />�� <br />o <br />5a <br />�w <br />W <br />m <br />a� <br />�3 <br />J�S <br />�O <br />< <br />I-Ir <br />v <br />w< <br />R <br />a0 <br />_1 <br />0 <br />2 O <br />= <br />In <br />>CD <br />LO <br />LO <br />Q <br />0 <br />L_ <br />00 <br />co <br />J <br />M <br />v J <br />m <br />m <br />LO <br />T <br />� <br />Q <br />0 <br />co <br />V� <br />N <br />CIO o <br />r <br />N <br />LL N_ <br />cr) O <br />O <br />T T-. <br />r <br />r <br />CD CM <br />E <br />c (� <br />_v <br />M <br />Z <br />f0 <br />z <br />E N <br />ij <br />a <br />ro <br />c <br />12-U <br />� <br />Q CIO) <br />JOB <br />NO : <br />23-02469 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.