Search
36472 Garden Wall Way
Zephyrhills
>
Building Department
>
Building Plans
>
36472 Garden Wall Way
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 3:58:51 AM
Creation date
2/19/2025 12:42:48 PM
Metadata
Fields
Template:
Building Plans
Street #
36472
Location
Garden Wall Way
Contractor
Lennar Homes LLC
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br />4 <br />3 <br />3 <br />4 <br />4 <br />4 <br />5 <br />4 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />UNDERGROUND <br />SERVICE BY POWER CO. <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17, 250.94 <br />150A/200A INDOOR <br />PANEL CENTER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />#14 to lights & outlets <br />#12:o appliances and GFI <br />#10 oWH <br />#8 to Range <br />#6 to HVAC <br />200=4/0 in 2" Conduit <br />— 4 Bare Cu Ground <br />#4 GROUNDING WIRE <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL <br />ELECTRICAL <br />NOTES <br />Tpical 150-200 Amp Electrical Riser DiagraM REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, <br />I =1 _+ ; 1 +1 4 k ; k+ A 4:� P. ; � A <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />e r ca ou e e g s as measure om ns e oor to center ne 0 L e box to be: 16 Arr kgenerai). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />LIL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1,2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />F� <br />DUPLEX CONVENIENCE OUTLET <br />I Z±' <br />Flq�� <br />DUPLEX OUTLET ABOVE COUNTER <br />KD:W:.P. <br />WEATHERPROOF DUPLEX OUTLET <br />O&F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />6 <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />�_o <br />WALL MOUNTED LIGHT FIXTURE <br />RECESSED LIGHT FIXTURE <br />4-P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUSTFAN <br />IV, <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CHIMES (OPTIONAL) <br />WEN <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SMOKE DETECTOR <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USI3 (OPTIONAL) <br />FV1 <br />TELEVISION (OPTIONAL) <br />FT7V 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A. F.F. <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />r I <br />I ALT I I <br />AC PAD <br />L <br />OPT. <br />U.C. OUTLET <br />SWITCH FOR <br />DISPOSAL <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />SPEC 3 & 4 KITCHEN <br />SCALE: 114"=1'-O" <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />F— — — — — — — — — — — — — — — — — — — <br />L------------------------------------ J <br />3" <br />RECEPT. FOR <br />ALARM SYSTEM <br />PROVIDE PHONE / CABLE <br />AND OUTLET AT TECH <br />CENTER <br />GFI @ <br />44" A. F.F. <br />—ill-3" VTR 1.5" VTR <br />—111 3" VTR <br />PLUMBING RISER <br />SCALE:NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />ELECTRICAL PLAN —A <br />SCALE: Y4"=l'-O" <br />C2 <br />C%4 <br />P. LU <br />C3 <br />C3 <br />C2- <br />C 4 <br />U_ <br />C= <br />CL <br />CIO <br />-0 <br />W <br />03 <br />a E <br />C"ll <br />CD <br />�_o <br />CD <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages beanng <br />Engineers signature and sea]. <br />0 E <br />C) co <br />0 <br />C14 C� 0) <br />C o <br />Sco ': <br />'3 00 <br />to 0) <br />co t- V <br />04 0 <br />co -4 <br />u- <br />_j L ul� <br />LL <br />1031% <br />EL �4 <br />Ca C U) <br />Z 5 C' <br />W <br />.=&7D <br />"5 Co <br />W <br />IL0mr- <br />L-0 Z� 0 <br />(1) <br />04 <br />< 0� 0 <br />Q < L) <br />Z <br />0 (1) <br />W <br />CD <br />< <br />V) <br />01110 <br />Q) <br />(D 8 <br />U-_ <br />+' <br />M <br />cf�- <br />LU <br />Q U <br />) <br />— <br />0 <br />V) <br />NY <br />LU <br />" <br />U) <br />ulft <br />A <br />(10 <br />C) <br />LU <br />sly <br />E <br />83 <br />U) <br />0 <br />to, <br />.4 <br />P_ <br />co <br />CO <br />Z <br />Z <br />< <br />_j <br />LL_ <br />ccF E <br />0 <br />U <br />co <br /><0 <br />Z <br />cu <br />C:, <br />CD E <br />0 <br />0 <br />0 <br />0 < <br />Luz <br />C'j <br />t <br />Lum <br />79� M <br />Z3 C <br />U) <br />.0 <br />1, <br />01 <br />Z <br />C: <br />C Q) <br />Z' <br />I Z <br />< <br />0) <br />0) <br />0 <br />2) <br />Z <br />W <br />< <br />'0 <br />1 <br />c::, <br />Z' <br />< <br />0 <br />W1 <br />C> <br />co <br />5 <br />'M <br />Lo <br />0 <br />CD <br />CID <br />co <br />=3 <br />< <br />(7 <br />co <br />C) <br />U) <br />�: <br />N <br />C <br />LO <br />0 <br />Q) <br />cc <br />(D C14 <br />C) <br />0-) <br />C\I <br />04 CD <br />LO <br />r1_ CNJ <br />CD <br />E <br />(.0 <br />CIO <br />�j 00 <br />0 <br />M <br />Z <br />E Ir— <br />ca <br />c: <br />Ca <br />a- I <br />E <br />0 0 <br />() _j <br />_0 03 <br />< Q 1 <br />(D <br />—1 <br />JOB <br />NO: <br />22-09404 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />-VI]TF1,"J'1111 -�� <br />