Laserfiche WebLink
KITCHEN <br />C7�� IO <br />IIII � -i I <br />O. BATH <br />mrL1n7w77,,, <br />KITCHEN <br />INTERIOR DETAILS <br />SCALE: 1/4" = V-0" <br />BATHROOM 2 <br />0 <br />0 <br />80 <br />0 <br />N <br />co <br />NOTE: THIS DIAGRAM DEPICTS TYPICAL INSTALLATION <br />VARIES, 2" LESS THAN GUIDELINES TO BE FOLLOWED U.N.O. ON PLANS 42" H UPPER <br />CABINETS BELOW CABINETS <br />- { H UPPER <br />CA <br />MIRROR I CABINETS � <br />SHWR. SHWR. DOUBLE 30" H UPPER <br />CURTAIN HEAD RODS 16 <br />12" FOR PANTRY " FOR LINEN <br />VARIES CABINETS -� <br />ROD <br />z SINGLE OVERHANGS THAT <br />24" TOWEL BAR g EXCEED 12" MAY <br />O TOWEL BAR IN a ROD REQUIRE A SUPPORT <br />w ON WALL ABOVE TUB OR SHWR. ¢ <br />C // TOILET TOWEL BAR - wa O BRACKET 36" H BASE <br />ON BATHROOM WALL O FINISHED CABINETS- <br />= 0 COUNTER TOP 30" H BASE <br />MEDICINE 4 r SHWR. ® ul c <br />CABINET °0 VALVES = co CABINETS - <br />TOILET t9 SOAP LL ^� <br />PAPER tO DISH J `� <br />r HOLDER Q O LO <br />v¢ cc R a) �? a O 2x <br />O Q 02 4 v M FRAMING CD <br />Cl) cNn Cl)�i iv M rF TUB BOARD <br />BATHROOMS, SHOWERS AND TUBS <br />CLOSETS/LAUNDRY SHELVING <br />io <br />4 1" <br />R 0o <br />--ISLAND COUNTER CABINET BLOCKING <br />BLOCKING AND MOUNTING DETAILS <br />SCALE: 1/4" = V-0" <br />WIRE SHELF @ -� <br />+54" A.F.F. <br />PLUMBING LINE -� <br />TO SECOND <br />FLOOR <br />DRYER VTE <br />HANSON BOX @� <br />36" A.F.F. <br />EXTERIOR WALL) <br />W/ 2x4 WALL <br />z W <br />PAD OUT <br />z <br />U Q <br />� <br />�U <br />�U <br />U <br />60_ <br />>wr� <br />U <br />o� <br />co 2 <br />10 <br />9S,-()„ <br />12'-0" <br />13'-0" <br />8'-3" 3'-9" <br />1 V-8" <br />.1 '4' <br />AC PAD <br />OHB <br />35-SH <br />■ ■ <br />■ <br />■. <br />■ <br />- - - - - - - - - - - - - - <br />- - - - - - - - <br />■ <br />NOOK <br />LANAI <br />I <br />1 <br />8'-8" FLAT CLG. <br />8'-0" FLAT CLG. <br />AFF <br />o TILE <br />T <br />- <br />I <br />12'-4" <br />O <br />6068 SGID <br />�. <br />J. <br />I <br />� <br />II <br />� <br />I <br />II <br />II <br />■ <br />0 1 <br />IR <br />a 'I <br />p El <br />; <br />z Fo-1 I <br />bN <br />r` <br />05� -- ; <br />FAMILY <br />�o <br />■ <br />I <br />8'-8" FLAT CLG. <br />■ <br />p I <br />CARPET <br />I� <br />ITCHE <br />2468 8'-8" FLAT CLG. <br />1'-0" TILE <br />(n <br />04 <br />FLOOR G.T.--- <br />_LO <br />6 <br />_ <br />~ REF. - --- <br />- - <br />----------- <br />5 ---N1-J <br />----- <br />ZD <br />T-74 <br />3 <br />2 <br />(3)2xSw/(3) SPF <br />DINING <br />■ <br />1 <br />STUDS w/ (3) 16d <br />GG NAILS @ BASE <br />8'-8" FLAT CLG. <br />■ <br />S3 00 <br />CARPET <br />0 <br />4'-2 " <br />T-3" <br />42" H 1/2 WALL <br />OR RAILING PER <br />SPECS <br />FLOOR G.T. <br />----------------- <br />10 <br />U <br />(3) 2x4 #2 SPF <br />■ <br />I O N <br />STUDS w/ (3) 16d <br />O <br />r 0 <br />NAILS @ BASE <br />1 �y. <br />4068 ARCH <br />PW D R <br />GG <br />v v <br />D. <br />S3 0 <br />c'8 8'-8" FLAT CLG. <br />�8 <br />(3) 2x4 #2 SPF <br />TILE <br />STUDS w/ HTT16 <br />PE NK OTp <br />b AT BASE <br />"FOYER <br />W' <br />LAU N <br />8'-8" FLAT CLG. Q <br />�° <br />8'-8" FLAT CLG. <br />TILE S4 <br />TILE <br />H <br />rllrllllllllllllltl <br />W <br />7'-2j„ 4,-0„ <br />6'-74' <br />6,„ <br />17'-10" <br />BUILDER TO 35 <br />10 <br />EDGE OF SLAB 2 <br />C,PROVIDE <br />APPLIANCE <br />■ <br />PROTECTION WHEN D1 <br />REQUIRED <br />PER FBC <br />NOTE: FINISHED WALLS <br />oo <br />TO BE FLUSH. FIELD <br />, M I <br />8'-8"CLG.A.F.F. <br />G.T. VERIFY_----- <br />I <br />- -- <br />------------------ <br />- -- <br />- - - - - - - - - - - - - <br />I <br />8'-0" CLG. A.F.F. <br />r I <br />_ <br />W LU <br />_ _ _ _ <br />- 4 i <br />ENTRY <br />w oI•---_ATTIC <br />z <br />I <br />-0" FLAT CLG. AFF <br />0 mL----'J <br />GARAGE <br />------ <br />W U Ij=- <br />O <br />8'-0" CLG. A.F.F. <br />� J > <br />00 <br />TYP. @ SINGLE N <br />STORY <br />A <br />S3 <br />(SEE AA/S3 FOR <br />STEM OPT.) <br />4' 4" 1'-4" <br />r--------------------------------- <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />K <br />I <br />I <br />I <br />I <br />I <br />S4 TYP. @ <br />I <br />I <br />I <br />GARAGE <br />O I <br />16070 OVERHEAD DOOR <br />V-8" <br />16-0" <br />V-8" <br />5'-8" <br />19'-4" <br />25'-0" <br />V-4"XV-4" "L" <br />SHAPE CMU <br />COLUMN <br />T <br />O <br />= VIA <br />TYP. @ 2 <br />STORY. SEE <br />JJ/S6 @ <br />STEMWALL <br />1,-4„ X1'-4„ „ L„ <br />SHAPE CMU <br />COLUMN <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2950 <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2950 <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2950 <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2950 <br />(2) - 2X4 #2 SYP W/ 1/2" <br />Follow Q/S4. See Plan for <br />RAG <br />FLITCH PLATE <br />Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />OA <br />+29.7 / -32.2 <br />© <br />+29.7 / -39.7 <br />© <br />+28.3 ! -30.8 <br />OD <br />+28.3 / -37.0 <br />OE <br />+26.6 I -29.1 <br />OF <br />+26.6 / -33.5 <br />OG <br />NET I-IO SEE SN SHEET <br />14PH <br />k <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +29.7 / -39.7 <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />182X25 <br />S.H. <br />13 <br />20 X 38 3 <br />18 1 X 37 <br />S.H. <br />14 <br />20 X 50 g <br />1812 X 50 <br />S.H. <br />15 <br />20 X 63 <br />181 X 62 2 <br />S.H. <br />16 <br />20X72 <br />1812X711 <br />S.H. <br />11­12 <br />27 1/4 X 26 <br />26 X 251 <br />S.H. <br />1H3 <br />271/4X38 <br />26x374' <br />S.H. <br />1 H4 <br />27 a X 50' <br />26 x 50 <br />S.H. <br />1 H5 <br />27 4 X 63 <br />26 X 62 1/2 <br />S.H. <br />1 H6 <br />27 a X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 J X 26 <br />3612 X 25 1/2 <br />S.H. <br />23 <br />37 J X 38 i <br />36 g X 37 3/4 <br />S.H. <br />24 <br />37 J X 5018 <br />36 1 X 50 <br />S.H. <br />25 <br />37 a X 63 <br />36 � X 62 1/2 <br />S.H. <br />26 <br />374' X 72 <br />3612 X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />731 WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 � X 25 J <br />S.H. <br />33 <br />54 X 38 J <br />52 2'X 371 <br />S.H. <br />34 <br />54 X 501 <br />52 i X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 2 X 621 <br />S.H. <br />36 <br />54 X 72 <br />52 J X 71 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />FIRST FLOOR PLAN - ELEV-B <br />SCALE: Ya"=V-0" <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection <br />Openings from a private garage directly into a room used for <br />sleeping purposes shall not be permitted. Other openings between <br />the garage and residence shall be equipped with solid wood doors <br />not less than 1-3/8" in thickness, solid or honeycomb -core steel <br />doors not less than 1-3/8" thick, or 20-minute fire -rated doors. <br />R302.5.2 Duct Penetration <br />Ducts in the garage and ducts penetrating the walls or ceilings <br />separating the dwelling from the garage shall be constructed of a <br />minimum No. 26 gage (0.48 mm) sheet steel, 1 inch minimum rigid <br />nonmetallic class 0 or classi duct board, or other approved <br />material and shall not have openings into the garage. <br />R302.5.3 Other Penetrations <br />Penetrations through the separation required in Section R302.6 <br />shall be protected as required by section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated as required by Table R302.6. <br />Openings in garage walls shall comply with Section R302.5. <br />Attachment of gypsum board shall comply with Tab;e R702.3.5. <br />The wall separation provisions of Table R302.6 shall not apply to <br />garage walls that are perpendicular to the adjacent dwelling unit <br />wall: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools <br />Outdoor swimming pools shall be provided with a barrier <br />complying with R4501.17.1.1 through R4501.17.1.14. <br />M1507.2 Re -circulation of Air <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />re -circulated within a residence or to another dwelling unit and <br />shall be exhausted directly to the outdoors. Exhaust air from <br />bathrooms and toilet rooms shall not discharge into an attic , crawl <br />space or other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />WALL LEGEND <br />TYP. 2x FRAME WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR <br />BEARING ONLY" ARE FLOOR SYSTEM <br />SUPPORTING ONLY AND REQUIRES NO <br />UPLIFT CONNECTORS TO FLOOR SYSTEM <br />AREA TABULATION <br />FIRST FLOOR LIVING AREA <br />SECOND FLOOR LIVING AREA <br />952 S.F. <br />1121 S.F. <br />TOTAL LIVING AREA <br />2073 S.F. <br />GARAGE <br />396 S.F. <br />LANAI <br />104 S.F. <br />ENTRY <br />32 S.F. <br />TOTAL SQ. FT. <br />2605 S.F. <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONIC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />JR-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />llvvN <br />ew <br />4 <br />F E SS``��P,`�,�� <br />r�1.I/f11I111100\ <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building <br />Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />W a <br />�EQ <br />o M J <br />� N <br />SNN <br />ro, <br />� <br />N m m <br />Y C <br />sF-°° <br />� ik <br />t) J <br />U, ju <br />LL <br />a <br />M 0 <br />LL <br />a l i <br />nw z <br />z <br />Z <br />_ <br />�°' <br />L a <br />0 o <br />W(1) <br />3 MNiD <br />T,' °' <br />p <br />m Q <br />a k z <br />Z <br />00 <br />C7 z <br />w <br />H <br />N <br />o <br />y <br />o00 <br />W <br />0 <br />- o <br />z CO <br />z <br />J - <br />CZ. <br />N <br />M <br />zCo <br />�, <br />LL <br />l <br />T <br />(� <br /><n <br />w � <br />o a <br />U <br />0 <br />c S <br />-N <br />®IN <br />r'n <br />U <br />� <br />• <br />iO4 <br />U c <br />N <br />I� <br />o <br />z< <br />w <br />Z <br />CAM <br />M <br />J <br />z <br />� <br />4 <br />� <br />w <br />m <br />wo <br />» <br />Q� <br />a O <br />E: U <br />oLL <br />W° <br />z <br />Z® <br />o a <br />H rod <br />o E <br />¢< <br />�o <br />gz <br />z <br />o ra <br /><� <br /><o <br />wz <br />oo <br />m0 <br />_Z <br />z <br />m J <br />ym <br />aZ. <br />zZ <br />N <br />d O <br />W <br />> <br />7 <br />C) <br />0¢ <br />w� <br />�w <br />m <br />�� <br />3 <br />o <br />J <br />wa <br />O <br />yo <br />NJc"> <br />v <br />is <br />d r <br />�3 <br />0 <br />c 0 <br />` <br />> M <br />J <br />Orn <br />M <br />N <br />t0 LO <br />LO <br />:3 r <br />_ <br />Q <br />Cr � <br />co <br />N <br />m <br />L0 <br />O <br />= <br />O <br />CM <br />0 <br />O <br />L <br />M <br />N <br />N <br />Q <br />� <br />T <br />M C` <br />cS <br />' r <br />rr' Ln <br />Z <br />Z <br />E CV <br />N <br />li <br />U J <br />Q0 <br />J <br />JOB <br />NO: <br />23-06123 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.1 <br />0 <br />