Laserfiche WebLink
3 <br />a <br />LO <br />L0 <br />v <br />U) <br />a <br />LO <br />O <br />0 <br />J <br />0 <br />rn <br />0 <br />I <br />N <br />LO <br />v <br />0 <br />.a <br />Q <br />Lo <br />J <br />0 <br />0 <br />I <br />A <br />Ln <br />L <br />b <br />Cr <br />an <br />Q <br />CD <br />l <br />E <br />E <br />O <br />2 <br />C <br />J <br />y <br />E2 <br />U <br />i <br />U <br />0 <br />i <br />a <br />0 <br />v <br />U <br />J <br />N <br />cZ <br />N <br />0 <br />0 <br />w <br />v <br />0 <br />0 <br />a. <br />N <br />N <br />0 <br />00 <br />Q <br />m <br />SEE ROOF <br />PLAN SHE <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />PROVIDE 2X4 MIN. BLOCKING AT <br />Q OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />N TRUSS <br />S <br />(2) 12D NAILS - <br />AT 12" O.C. MAX <br />HIP <br />G.T <br />(2) 2x8 #2 SYP w, <br />O.S.B. FLITCH PI <br />TOP @ TRUSS E <br />U.N.O. ON ROOF <br />PLAN <br />TYPIC <br />WALL <br />NOTE: PENDING BEAM <br />BEARING LOCATION, THE <br />BEAM CAN SIT ON TOP OF <br />COLUMN w/ (2) SIMPSON <br />HTS20 w/ (24) 10d x 1 1/2" <br />NAILS EACH <br />SIMPSON HU46/HUC46 w/ (8) <br />16d NAILS TO POST & (4) 10d <br />NAILS TO BEAM <br />SUPPORT COLUMN BUILT-UP <br />(2) 2x4's OR 4x4 w/ (2) 10d <br />NAILS @ 8" O.C. EACH PLY <br />(SHOWN AS 4 x 4) <br />(2) SIMPSON HETA20 w/ (8) 10d <br />x 1 1/2" NAILS EACH - OR (2) <br />SIMPSON MSTAM36 w/ (7) 10d <br />& (4) 1/4"x2 1/4" TITENS EACH <br />TIE BEAM <br />JACK TRUSS (AS SHOWN) <br />OR GABLE END SEE TRUSS <br />LAYOUT <br />CLIP EACH TRUSS <br />(SEE ROOF PLAN <br />FOR TYPE) <br />FRAME OUT TO <br />BLOCK EDGE <br />SEE PLAN <br />FOR BEAM SIZE <br />EXTERIOR SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE 2x SPF #2 <br />AT 16" O.C. <br />BUILDER FRAME <br />RADIUS <br />AS REQUIRED <br />�A/2-1 l:I@EACHTRUS < <br />BEAM @ <br />RAISED ENTRY <br />E <br />w/ 2-16d @EACH TRUSS WEB <br />CROSS BRACING DETAIL JYP.)(*", <br />HIP/RIDGE BLOCKING DETAIL 2 <br />MASONRY WALL r4 <br />KNEEWALL <br />ENTRY FRONT WALL 6 <br />SCALE: NTS <br />SCALE: NTS <br />SCALE: NTS <br />SCALE: NTS <br />TRUSS NOTES. TYP. HAND FRAMING ABOVE TRUSS <br />CONV. FRAMED RIDGE 2X4 STUDS & PLATES AT 2'-0" O.C. <br />1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 MAY BE NAILED EACH DIRECTION TYP. U.N.O. <br />SIMPSON LSTA18 <br />SEE PLAN <br />TRUSS PLATE INSTITUTE NOTE THAT THE COMBINED WIND AREA IS GREATER VERTICAL SCAB 2 x 6 <br />( ) w/MIN. (4) 12d WHEN <br />w/ (12) 1Od NAILS <br />= <br />SIMPSON HUC410 w/ (14) <br />FOR CANT. <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO #2 SPF 48" O.C. W/ (4) <br />2x8 BLOCKING NAILED @ 10d TOP & BOTTOM <br />CENTERED AT <br />SPLIT TO TIE <br />16d INTO HEADER & (6) <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS EACH SIDE w/ 3 12d NAILS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES O OR SIMPSON H2.5A w/ <br />BEAMS TOGETHER <br />INTO BEAM -SEE <br />ROOF <br />ROOF PLAN FOR MORE <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD WHEN REQUIRED (10) 8d NAILS <br />INFO <br />/ ( 4) <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & HTS20 w/ (24) 10d x <br />1 1/2" NAILS <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION 1 1/2" NAILS EACH <br />SEE FLOOR PLAN FOR <br />COLUMN SIZE & BASE <br />7/16" OSB FLITCH PLATE <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />SEE FLOOR PLAN <br />CONNECTION INFO <br />REQ'D ONLY WHEN <br />2x4 #2 SYP NAILER. NAIL <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO TO <br />COLLAR TIE <br />FOR COLUMN SIZE <br />INDICATED ON BM. <br />TO STUDS w/ (3) 16d AT <br />AS AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />EVERY 3rd <br />& ADDITIONAL INFO. SCHEDULE/PLAN <br />—7/16" OSB FLITCH PLATE SEE FLOOR PLAN FOR <br />EACH STUD -TOENAIL7--PER <br />ROOF AND EXTERIOR <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />RAFTER <br />REQ'D ONLY WHEN COLUMN SIZE & BASE <br />EACH TRUSS TO NAILER <br />SHEATHING ATTACHED <br />NAILING SCHEDULE <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />DICATEDE/P N BM OPTION <br />OPTION A <br />B CONNECTION INFO <br />OPTION C. <br />w/ (3) 10d <br />O.C. MAXIMUM. <br />2x4 SPF 2 (2) #7 x 3-1/2" <br />S <br />SEE 2ND FLOOR WALL SECTION <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER &SHALL BE ATTACHED w/ (3) 12d <br />WOOD SCREW EACH <br />TRUSS OR SIMPSON <br />FOR ADDITIONAL INFORMATION <br />NAILS AT EACH TRUSS INTERSECTION. CB <br />H2.5A 8d NAILS <br />COMMON B M TO POST ATTACHMENT <br />A <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />w/ (10) <br />. <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />TB <br />AT 48" O.C. <br />SEE ROOF PLAN <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. pg <br />B <br />FOR BEAM SIZE & SCALE: 3/4"=1'-0" <br />IF 2x DOUBLE LEDGER, <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />BEVEL CUTS <br />CONNECTION INFO. <br />BM. SPLICE OVER <br />CENTER OF POST <br />ATTACH FIRST PLY <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS <br />(OPTIONAL) <br />A <br />A <br />w/ (4) 16d NAILS TO EA. <br />PRE-ENG. TRUSS <br />END OF TRUSS THEN <br />2X4 BLOCKING <br />2X4 DIAGONAL AT 8'-0" O.C. BETWEEN EA. TRUSS CONT. ROOF SHEATHING AT TRUSS TOP <br />SEE PLAN FOR <br />TOP OF BEAM <br />ATTACH SECOND PLY <br />w/ (3) ROWS OF 16d <br />MAX & EACH END ALTERNATE <br />CHORD AT ALL HAND FRAMED AREAS TYP. <br />o <br />NAILS AT 24" O.C. <br />• <br />DIRECTION TYP. <br />A <br />0 0 <br />a o 0 <br />0 <br />o a o a <br />• <br />DIAGONAL <br />2x8 #2 SPF RIDGE BEAM <br />SIMPSON LUS26 w/ (8) 10d NAILS <br />• <br />AT 8'-0" <br />MAX <br />WOOD <br />TRUSS jC <br />•�C 2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />SIMPSON MTS18 w/ (14) <br />OR IF 2 PLY TRUSS SIMPSON <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />10d NAILS TYP. U.N.O. <br />SEE PLAN FOR SIMPSON <br />LUS26-2 w/ (8) 16d NAILS TO/01 <br />SEE FLOOR FRAMING PLAN <br />THAN 4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />CANTILEVER IF MTS18 w/ (14) <br />LEDGER <br />AND J/S6 FOR MORE INFO. <br />COMMON TOENAILS TO TIE BEAM <br />SEE FLOOR PLAN FOR <br />COLUMN SIZE & <br />INDICATED 10d NAILS <br />TYP. U.N.O. <br />2X10 #2 SYP CONT. LEDGER w/ (3) <br />VERIFY WITH PLAN FOR <br />LOCATION AND DIRECTION <br />2X4 CONT. AT <br />CONC. MASONRY <br />ADDITIONAL INFO. <br />1/2" X 4 1/2" LAG SCREWS ATTACH <br />LAG SCREWS INTO END OF EACH <br />2/D2 FOR <br />BLOCKING <br />T & B CHORD <br />STEEL OR WOOD <br />(WOOD COLUMN SHOWN) <br />MIDDLE <br />FLOOR TRUSS, 24" O.C. MAX. (AT <br />INFO) <br />BEARING SUPPORT <br />° <br />EACH SIDE OF G.T. INSTALL (4) LAG <br />MASONRY WALL <br />° <br />SCREWS EACH SIDE) <br />(TYPICAL) <br />A -A ALTERNATE BLOCKING <br />CORNER <br />SECTION AT LOW ROOF g <br />SEE FOUNDATION <br />DETAIL @ INTERIOR BEARING <br />5" <br />PLAN FOR MORE INFO <br />SCALE: NTS <br />3 <br />SCALE:NTS <br />COMMON BM. ATTACHMENT 18 <br />—WOOD TRUSS <br />'4 PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SCALE: NTS <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />TYP. WOOD TRUSS BLOCKING DETAIL STANDARD HEEL HEIGHT <br />SCALE: NTS <br />VARIES <br />2x STUDS @ 16" O.C. <br />ROOF SHEATHING <br />SEE 1/S5 FOR <br />SEE PLAN FOR <br />w/ SIMPSON SP1 w/ (10) 10d <br />ATTACHED PER <br />ADDITIONAL <br />8d NAILS AT <br />VALLEY TRUSS <br />& <br />NAILS (T) <br />2x4 #2 SPF BRACING @ <br />NAILING SCHEDULE <br />OUTLOOKER <br />4" O.C. <br />INFO. <br />ATSIMPSON <br />SP2 w/ 12 10d NAILS AT TOP <br />1Od NAILS <br />EXTERIOR SHEATHING <br />INFO. <br />16" O.C. W/ (4) 12d <br />COMMON TRUSSES. <br />ATTACHED PER <br />2x BLOCKING BETWEEN STUDS <br />TOENAILS TO TOP <br />SEE TRUSS PLAN <br />2x4 STUDS w/ SIMPSON <br />NAILING SCHEDULE <br />TO TRUSS W! (2) 12d TOENAILS <br />STRUCTURAL SHEATHING <br />PLATE & (2) 12d END <br />MIN. (2) 2x4 <br />FOR CONNECTION <br />SP1 w/ (10) 10d NAILS <br />EACH END ( BETWEEN TRUSSES <br />ATTACHED PER NAILING <br />NAILS TO TRUSS <br />SPF TOP <br />INFORMATION. <br />AT BASE SEE J/S6 FOR <br />GABL <br />LOW ROOF/WALL <br />(2)12d NAILS TO EACH VERTICAL <br />SCHEDULE <br />BOTTOM CHORD <br />PLATE <br />MORE INFO. <br />TRUSS <br />SHEATHING ATTACHED <br />STUD) <br />PER NAILING SCHEDULE <br />2x BASE PLATE W/ (2) 12d <br />VARIES W/ <br />VARIES SEE PLAN <br />FOR WALL LOCATION <br />2x4 BASE PLATE W/ <br />1/2" PLYWOOD <br />NAILS @ 16" O.C. ALONG W/ <br />ROOF SLOPE <br />SIMPSON LSTA30 w/ <br />SIMPSON MTS12 w/ (14) 10d x <br />(22) 10d NAILS OR <br />16d NAILS TO <br />1 1/2" NAILS TO <br />WOOD WALLSS/ <br />SIMPSON MTS12 w/ <br />E <br />EACH COMMON <br />FRAMING <br />BELOW @ 16' O COCKING <br />OR TRUSS. <br />2X4 CONT. W/ (2) <br />MIN. 2x4 #2 SPF STUDS @ <br />1 <br />(14) 10d x 1 1/2" NAILS <br />ryp TOP &BOTTOM <br />SEE PLAN <br />16d COMMONS <br />16" O.C. W/ EXTERIOR <br />TO FLOOR GIRDER <br />NAILS EACH <br />SHEATHING ATTACHED <br />BELOW @ 16" O.C.xx <br />e <br />STUD TYP. T&B <br />PER NAILING SCHEDULE & <br />MASONRY WALL BELOW: SIMPSON <br />PLYWOOD <br />(3) 12d TOENAILS TO <br />----- -- <br />a <br />°' <br />HETA16 w/ (9) 10d x 1 1/2" NAILS @ <br />FLOORIG <br />N <br />TRUSS OR <br />SEE PLAN FOR <br />PLATE BELOW <br />--- — -- _. <br />MASONRY WALL <br />4'-0" O.C. TO GABLE TRUSS <br />ROOF SYSTEM <br />TOP OF WALL <br />OR BEAM <br />. BEAM BELOW: SIMPSON HTS20 w/ <br />• <br />o <br />MIN. 2x4 #2 SYP P.T. PLATE <br />16" FLOOR SYSTEM FLOOR GIRDER <br />SEE TRUSS PLAN <br />a ° <br />(24) 10d x 1 1/2" NAILS @ 4'-0" O.C. <br />°. <br />W/ 1/2"X8" EPDXY ANCHOR <br />SEE PLAN FOR SEE PLAN FOR <br />TO GABLE TRUSS <br />LOW ROOF TRUSS W/ <br />(2) 2x6 BLOCKING UNDER FLOOR G.T. <br />lb <br />MASONRY WALL SEE <br />@ 3" FROM EACH END & <br />DIRECTION CONNECTION <br />COMMON TRUSS <br />RAISED BOTTOM CHORD <br />2nd FLOOR WALL w/ SEE PLAN <br />PLAN FOR MORE <br />16" O.C. MAX. <br />�° <br />SEE ROOF PLAN <br />EXTENSION SEE TRUSS <br />SIMPSON LUS24-2 w/ (16) <br />SHEAR TRANSFER <br />INFO. <br />>p <br />SECTION @FLOOR <br />FOR CONNECTION <br />16d NAILS AT EACH END <br />CONNECTIONS TO G.T. <br />EXTERIOR. WALL <br />SECTION ENTRY s <br />CONNECTION "22 <br />SECTION AT <br />HIP GABLE �2 <br />SECTION @ <br />BUMP OUT 39 <br />SCALE: NTS <br />SCALE: NTS <br />SCALE: NTS <br />SCALE: NTS <br />SCALE: NTS <br />DETAILS <br />& SECTIONS <br />c•N <br />s� <br />00 o <br />c C = <br />� y <br />a � <br />Leo, <br />CDL; C1. C:7 <br />� m X <br />N R C i <br />CG 3 cc <br />,a <br />e <br />CD <br />0 <br />VV .r <br />ro <br />ew <br />UA <br />r <br />r <br />�F <br />L0 <br />OFESSI�� <br />OJlJ111111 <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code -. <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />W vE <br />F` co <br />o S <br />g <br />C' <br />U " - <br />O �r <br />3 -1 <br />!'n r . <br />QNMI LL <br />C LL W <br />u LL a -J <br />Z — o Lu <br />. <br />c m v <br />o <br />w 0 <br />W � @ r- <br />?• 'Cc 0 <br />n N ZLL Q .� <br />ZN OU 8 <br />W <br />V M � <br />z N M <br />0 0 <br />z W <br />¢NN <br />Z o Q <br />Q <br />r <br />./ ! zO <br />y1 . ! Il C <br />W \J O <br />LU <br />o <br />V <br />O,,, o <br />N c <br />VN <br />ass <br />(a I— U) <br />v <br />yl0 <br />8111111111 W L U <br />o � <br />o• <br />N 0 <br />M111111 <br />o <br />CC) <br />w <br />CM <br />M <br />N ¢ <br />z <br />z <br />4 <br />LPL <br />E <br />zo <br />o o <br />yN <br />z< <br />OUro <br />Z® <br />oa <br />O <br />X U <br />oa <br />00 <br />U <br />o� <br />O <br />o <br />a ~p <br />¢o <br />G <br />d z <br />�J <br />>_ <br />C <br />p <br />OU <br />m <br />z <br />C J <br />W, <br />m <br />U <br />Q W <br />) <br />U <br />Q <br />oQ <br />z Z <br />go <br />a <br />ci <br />a0 <br />J <br />CD <br />6 w <br />= H <br />7 <br />CDui <br />co <br />� <br />'0 <br />a <br />°U3 <br />Oz¢ <br />C O <br />0 <br />>(9 <br />LOLO <br />rn <br />co <br />.- <br />Q <br />0 <br />O cc <br />O <br />3 <br />O <br />J <br />T <br />�C <br />� m CIO <br />N <br />m <br />L^ i <br />r <br />a--+ -0 CV <br />a) <br />o <br />O <br />C7 <br />0 N <br />O <br />O <br />Ln <br />r <br />T <br />(D oo <br />M <br />LO <br />o <br />z <br />CU <br />z <br />`� <br />E Q w <br />a <br />E i6 <br />U -j Q p <br />JOB <br />NO: 22-09410 <br />SCALE : AS NOTED <br />SHEET NO. <br />D1 <br />