FBC 2004 RESIDENTIAL SECTION R320
<br />PROTECTION AGAINST TERMITES
<br />R320.1
<br />TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES,
<br />INCLUDING SOIL APPLIED PESTICIDES, BAITING SYSTEMS, AND PESTICIDES
<br />APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE
<br />PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW
<br />CONSTRUCTION (SEE SECTION 202, REGISTERED TERMITICIDE). UPON
<br />COMPLETION OF THE APPLICATION OF THE TERMITE PROTECTIVE
<br />TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE
<br />BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT
<br />CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A
<br />COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN
<br />TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS
<br />ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND
<br />CONSUMER SERVICES."
<br />CHEMICAL SOIL TREATMENT, INCLUDING SPACES BOXED OR FORMED.
<br />R320.1.1
<br />IF SOIL TREATMENT USED FOR SUBTERRANEAN TERMITE PREVENTION,
<br />THE INITIAL CHEMICAL SOIL TREATMENT INSIDE THE FOUNDATION
<br />PERIMETER SHALL BE DONE AFTER ALL EXCAVATION, BACKFILLING AND
<br />COMPACTION IS COMPLETE.
<br />R320.1.2
<br />IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION,
<br />SOIL AREA DISTURBED AFTER INITIAL CHEMICAL SOIL TREATMENT SHALL
<br />BE RETREATED WITH A CHEMICAL SOIL TREATMENT, INCLUDING SPACES
<br />BOXED OR FORMED.
<br />R320.1.3
<br />IF SOIL TREATMENT IS USED F6R SUBTERRANEAN TERMITE PREVENTION,
<br />SPACE IN CONCRETE FLOORS BOXED OUT OR FORMED FOR THE
<br />SUBSEQUENT INSTALLATION OF PLUMBING TRAPS, DRAINS OR ANY OTHER
<br />PURPOSE SHALL BE CREATED BY USING PLASTIC OR METAL
<br />PERMANENTLY PLACED FORMS OF SUFFICIENT DEPTH TO ELIMINATE ANY
<br />PLANNED SOIL DISTURBANCE AFTER INITIAL CHEMICAL SOIL TREATMENT.
<br />R320.1.4
<br />IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION,
<br />CHEMICALLY TREATED SOIL SHALL BE PROTECTED WITH A MINIMUM 6 MIL
<br />VAPOR RETARDER TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL
<br />OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS
<br />REQUIRED. ANY WORK, INCLUDING PLACEMENT OF REINFORCING STEEL,
<br />CHEMICAL TREATMENT UNTIL THE CONCRETE FLOOR IS
<br />OURED, SHALL BE DONE IN SUCH MANNER AS TO AVOID PENETRATING
<br />OR DISTURBING TREATED SOIL.
<br />R320.1.5
<br />IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION,
<br />CONCRETE OVERPOUR OR MORTAR ACCUMULATED ALONG THE EXTERIOR
<br />FOUNDATION PERIMETER SHALL BE REMOVED PRIOR TO EXTERIOR
<br />CHEMICAL SOIL TREATMENT, TO ENHANCE VERTICAL PENETRATION OF
<br />THE CHEMICALS.
<br />R320.1.6
<br />IF SOIL TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION,
<br />CHEMICAL SOIL TREATMENTS SHALL ALSO BE APPLIED UNDER ALL
<br />EXTERIOR CONCRETE OR GRADE WITHIN 1 FOOT (305 MM) OF THE
<br />PRIMARY STRUCTURE SIDEWALLS. ALSO, A VERTICAL CHEMICAL BARRIER
<br />SHALL BE APPLIED PROMPTLY AFTER CONSTRUCTION IS COMPLETED,
<br />INCLUDING INITIAL LANDSCAPING AND IRRIGATION/SPRINKLER
<br />INSTALLATION. ANY SOIL DISTURBED AFTER THE CHEMICAL VERTICAL
<br />BARRIER IS APPLIED SHALL BE PROMPTLY RETREATED.
<br />R320.1.7
<br />IF A REGISTERED TERMITICIDE FORMULATED AND REGISTERED AS A BAIT
<br />SYSTEM IS USED FOR SUBTERRANEAN TERMITE PREVENTION, SECTIONS
<br />ROUGH R320.1.6 DO NOT APPLY; HOWEVER, A SIGNED
<br />ONTRACT ASSURING THE INSTALLATION, MAINTENANCE AND MONITORING
<br />OF THE BAITING SYSTEM FOR A MINIMUM OF FIVE YEARS FROM THE
<br />ISSUE OF THE CERTIFICATE OF OCCUPANCY SHALL BE PROVIDED TO THE
<br />BUILDING OFFICIAL PRIOR TO THE POURING OF THE SLAB, AND THE
<br />SYSTEM MUST BE INSTALLED PRIOR TO FINAL BUILDING APPROVAL. IF
<br />THE BAITING SYSTEM DIRECTIONS FOR USE REQUIRE A MONITORING
<br />PHASE PRIOR TO INSTALLATION OF THE PESTICIDE ACTIVE INGREDIENT,
<br />THE INSTALLATION OF THE MONITORING PHASE COMPONENTS SHALL BE
<br />DEEMED TO CONSTITUTE INSTALLATION OF THE SYSTEM.
<br />R320.1.8
<br />I A I TERED
<br />TREATMENT IS USED FOR SUBTERRANEAN TERMITE PREVENTION,
<br />SECTIONS R320.1.1 THROUGH R320.1.6 DO NOT APPLY. APPLICATION OF
<br />THE WOOD TREATMENT TERMITICIDE SHALL BE AS REQUIRED BY LABEL
<br />DIRECTIONS FOR USE, AND MUST BE COMPLETED PRIOR TO FINAL
<br />BUILDING APPROVAL.
<br />R320.2 PENETRATION.
<br />PROTECTIVE SLEEVES AROUND METALLIC PIPING PENETRATING CONCRETE
<br />SLAB -ON -GRADE FLOORS SHALL NOT BE OF CELLULOSE- CONTAINING
<br />MATERIALS AND, IF SOIL TREATMENT IS USED FOR SUBTERRANEAN
<br />TERMITE PROTECTION, SHALL RECEIVE APPLICATION OF A TERMITICIDE IN
<br />ANNULAR SPACE BETWEEN SLEEVE AND PIPE.
<br />R320.3 CLEANING.
<br />CELLS AND CAVITIES IN MASONRY UNITS AND AIR GAPS BETWEEN BRICK,
<br />STONE OR MASONRY VENEERS AND THE STRUCTURE SHALL BE CLEANED
<br />OF ALL INIONPRESERVATIVE TREATED OR NONNATURALLY DURABLE WOOD,
<br />OR OTHER CELLULOSE -CONTAINING MATERIAL PRIOR TO CONCRETE
<br />PLACEMENT.
<br />EXCEPTION: INORGANIC MATERIAL MANUFACTURED FOR CLOSING CELLS IN
<br />FOUNDATION CONCRETE MASONRY UNIT CONSTRUCTION OR CLEAN EARTH
<br />FILL PLACED IN CONCRETE MASONRY UNIT VOIDS BELOW SLAB LEVEL
<br />BEFORE TERMITE TREATMENT IS PERFORMED.
<br />R320.4 CONCRETE BEARING LEDGE.
<br />BRICK, STONE OR OTHER VENEER SHALL BE SUPPORTED BY A
<br />CONCRETE BEARING LEDGE AT LEAST EQUAL TO THE TOTAL THICKNESS
<br />OF THE BRICK, STONE OR OTHER VENEER, WHICH IS POURED INTEGRALLY
<br />WITH THE CONCRETE FOUNDATION. NO SUPPLEMENTAL CONCRETE
<br />FOUNDATION POURS WHICH WILL CREATE A HIDDEN COLD JOINT SHALL
<br />BE USED WITHOUT SUPPLEMENTAL TREATMENT IN THE FOUNDATION
<br />UNLESS THERE IS AN APPROVED PHYSICAL BARRIER. AN APPROVED
<br />PHYSICAL BARRIER SHALL ALSO BE INSTALLED FROM BELOW THE WALL
<br />SILL PLATE OR FIRST BLOCK COURSE HORIZONTALLY TO EMBED IN A
<br />MORTAR JOINT, IF MASONRY VENEER EXTENDS BELOW GRADE, A TERMITE
<br />PROTECTIVE TREATMENT MUST BE APPLIED TO THE CAVITY CREATED
<br />BETWEEN THE VENEER AND THE FOUNDATION, IN LIEU OF A PHYSICAL
<br />BARRIER.
<br />EXCEPTION: VENEER SUPPORTED BY A SHELF ANGLE OR LINTEL
<br />SECURED TO THE FOUNDATION SIDEWALL IN ACCORDANCE WITH ACI
<br />530/ASCE 5/TMS 402, PROVIDED AT LEAST A 6-INCH (152 MM) CLEAR
<br />INSPECTION SPACE OF THE FOUNDATION SIDEWALL EXTERIOR EXIST
<br />BETWEEN THE VENEER AND THE TOP OF ANY SOIL, SOD, MULCH OR
<br />OTHER ORGANIC LANDSCAPING COMPONENT, DECK, APRON, PORCH, WALK
<br />OR ANY OTHER WORK IMMEDIATELY ADJACENT TO OR ADJOINING THE
<br />STRUCTURE.
<br />R320.5 PRESSURE PRESERVATIVELY TREATED AND NATURALLY
<br />RESISTANT WOOD.
<br />HEARTWOOD OF REDWOOD AND EASTERN RED CEDAR SHALL BE
<br />CONSIDERED TERMITE RESISTANT. PRESSURE PRESERVATIVELY TREATED
<br />WOOD AND NATURALLY TERM[ TE- RESISTANT WOOD SHALL NOT BE USED
<br />AS A PHYSICAL BARRIER UNLESS A BARRIER CAN BE INSPECTED FOR
<br />ANY TERMITE SHELTER TUBES AROUND THE INSIDE AND OUTSIDE EDGES
<br />AND JOINTS OF A BARRIER.
<br />R320.5.1 FIELD TREATMENT.
<br />FIELD CUT ENDS, NOTCHES AND DRILLED HOLES OF PRESSURE
<br />PRESERVATIVELY TREATED WOOD SHALL BE RETREATED IN THE FIELD IN
<br />ACCORDANCE WITH AWPA M4.
<br />R320.6 FOAM PLASTIC PROTECTION.
<br />EXTRUDED AND EXPANDED POLYSTYRENE, POLYISOCYANU RATE AND
<br />OTHER FOAM PLASTICS SHALL NOT BE INSTALLED ON THE EXTERIOR
<br />FACE OR UNDER INTERIOR OR EXTERIOR FOUNDATION WALLS OR SLAB
<br />FOUNDATIONS LOCATED BELOW GRADE. THE CLEARANCE BETWEEN FOAM
<br />PLASTICS INSTALLED ABOVE GRADE AND EXPOSED EARTH SHALL BE AT
<br />LEAST 6 INCHES (152 MM).
<br />EXCEPTIONS:
<br />1. BUILDINGS WHERE THE STRU U AL F WALLS, FLOORS,
<br />CEILINGS AND ROOFS ARE ENTIRELY OF NONCOMBUSTIBLE MATERIALS OR
<br />PRESSURE PRESERVATIVELY TREATED WOOD.
<br />2. WHEN IN ADDITION TO THE REQUIREMENTS OF SECTION R320.1, AN
<br />APPROVED METHOD OF PROTECTING THE FOAM PLASTIC AND STRUCTURE
<br />FROM SUBTERRANEAN TERMITE DAMAGE IS PROVIDED.
<br />3. ON THE INTERIOR SIDE OF BASEMENT WALLS.
<br />GENERAL NOTES
<br />Bathroom #2 - Hall
<br />- Demo existing door and frame.
<br />- Re-frome opening for a 36" wide door.
<br />- Install new 3'0" x 6'8" pre -hung, hollow core door unit with lever
<br />lock.
<br />- Mortise trim on inside of door to fit against wall and vanity.
<br />- Point door and frame completely.
<br />- Install horizontal grab bar in front of toilet at height suitable to
<br />owner.
<br />- Remove and replace regular toilet with new handicap toilet and
<br />seat.
<br />Kitchen
<br />Cut the west countertop, south end, back approximately 20"
<br />removing the south door of that base cabinet. Using the west
<br />side and the south end, make two side legs to hold top, Lower
<br />countertop height down to 31" high, 29" clear height. Install
<br />splash between 36" countertop height and new 31" height.
<br />Reinstall end panel 20" north. Patch as necessary wood floor in
<br />20" x 25" area where base cabinet was removed for a roll -under
<br />area.
<br />Utility Room
<br />- Demo southwest corner of existing utility room.
<br />- Demo from edge of door in room, northwest at an angle
<br />approximately 7 LF from southwest existing corner. By removing
<br />90 degree corner and installing an angle wall approximately 7 LF
<br />long, you will create a walkway approximately 42" wide so that a
<br />wheelchair con travel from back patio to carport and be under
<br />roof and out of weather.
<br />- Relocate one wall light, one light switch, and one wall outlet.
<br />- Re -frame new angle wall and reinstall existing vinyl lap siding.
<br />- Provide all necessary vinyl lop components to tie new design into
<br />existing design.
<br />Interior will remain as is with exposed studs.
<br />Remove existing block skirting on west side of sidewalk for
<br />approximately 12 LF and install vinyl in place of block to gain 4"
<br />of width.
<br />Master Bathroom
<br />- Demo toilet.
<br />- Demo bathroom door and frame.
<br />- Demo two toilet room walls (west and south),
<br />- Demo vanity top, sinks, faucets, and base cabinets.
<br />- Demo mirror above vanity.
<br />- Save sinks, faucets, and mirror to reinstall.
<br />- Demo shower walls, shower valve, shower floor and floor drain.
<br />- Demo wall cabinet - reinstall in bedroom closet.
<br />- Demo floor covering in bathroom.
<br />- Demo north wall, east end, for a new 36" door.
<br />- Frame in new door opening. Frame to close up old door opening.
<br />- Rough in plumbing: Install toilet water line, east wall, south end,
<br />(corner of room) and its 4" drain line in floor.
<br />- Rough in new shower valve and center drain in 5x5 shower floor
<br />area in old shower area southwest corner of bathroom. Vanity area
<br />remains as is with rough plumbing.
<br />- Install pressure treated 2x4's north and south and spaced 12"
<br />apart across all of bathroom floor. 2x4's will lay flat on 3-1/2"
<br />side and will not be installed in shower area.
<br />- In front of new door, 36" wide and 36" into bathroom, cut
<br />sleepers (2x4's) at on angle to create a 1 to 12 slope for a
<br />ramp.
<br />install ?" pressure treated plywood on top of sleepers.
<br />I nsz a 11 16" durarock on top of plywood. This will be done
<br />throughout oil of bathroom floor except in shower area which will
<br />remain at existing floor height.
<br />Rough in electric: Remove fan/light from toilet room and its two
<br />switches. Balonc,- of electric remains the some.
<br />Install shower pan.
<br />Install durarock on three walls of shower area up 6 LF above floor.
<br />- Install mud set on shower floor; slope all four sides to center
<br />drain.
<br />- Install moisture rcsistant drywall on walls of bathroom as
<br />necessary due to demo, plumbing and electric relocation.
<br />- Install ceramic tile on three walls of shower up 6 LF above floor.
<br />- Install ceramic tile on shower floor.
<br />- Install marble sills on two open faces of shower floor to stop
<br />flowing water.
<br />- Install new 3'0" x 6'8" hollow core, pre -hung door unit with lever
<br />lock in bathroom.
<br />- Install ceramic tile floor on balance of floor outside of shower.
<br />- Install marble sill at door.
<br />- Point bathroom walls, doors, and trim completely.
<br />- Install 36" vanity cabinet.
<br />- Install 72" long x 22" deep countertop. South 36" of vanity will
<br />be a roll -under area. Countertop will hove three wall splashes.
<br />- Install new handicap toilet and seat.
<br />- Reinstall two existing sinks and faucets in vanity area.
<br />- Reinstall existing mirror above vanity.
<br />- Trim out sho-.,,er valve. Install hand-held shower wand and slide
<br />bar.
<br />- Install three wall mounted grab bars in shower.
<br />- Install one wall mounted grab bar on wall beside toilet and one
<br />fold -down bar on opposite side of toilet.
<br />- Install ceiling track and shower curtain. Track to have one radius
<br />turn
<br />- Install 3' handrail on west side of romp to protect edge.
<br />Master Bedroom
<br />- Move furniture.
<br />- Demo carpet, pod, and tack strip.
<br />- Install new wood floors in 13' x 16' bedroom.
<br />- Reinstall furniture.
<br />Livinci Room
<br />- Move furniture.
<br />- Demo carpet, pod, and tack strips.
<br />- Install new wood floors in 16' x 26' living room.
<br />.�,nin-Q-Room
<br />Move furniture.
<br />Demo carpet, pGd, and tack strips.
<br />install new wood floors in 8x13 dining room.
<br />Reinstall furniture.
<br />Hallway
<br />- Demo carpet, pod, and tack strips.
<br />- Install wood floors in 4x8 hallway.
<br />Comouter Room
<br />- Move furniture.
<br />- Demo carpet, pod, and tack strips.
<br />- Install new wood floor in 11 x 13 room.
<br />- Reinstall furniture.
<br />Guest Bedroom
<br />- Move furniture.
<br />- Demo carpet, pod and tack strips.
<br />- Install wood floors in 12 x 13 room.
<br />- Reinstall furniture.
<br />Familv Room
<br />- Remove sliding gloss doors and frame.
<br />- Install pre -hung French doors with lever lock and deadbolt.
<br />Install trim both sides.
<br />- Paint new French doors and frame completely.
<br />- Move furniture.
<br />- Demo carpet, pod, and tack strips.
<br />- Install wood floors in 13 x 16 room.
<br />- Reinstall furniture.
<br />Sun Room
<br />- Demo carpet from floor; save to reinstall.
<br />- Demo aluminum pan roof, fan beam, and fan.
<br />- Demo vinyl lop siding on west wall, and north on the
<br />exterior of the sun room.
<br />- Demo lap siding from all inside walls; save to reinstall.
<br />- Demo five windows and one door; save to reinstall.
<br />- Demo A/C unit; save to reinstall.
<br />- Install new 3" elite panel roof in sun room approximately 13
<br />x 13. North and west walls to hove a 12" overhang with a
<br />gutter and downspout on north wall. Elite panel to hove a
<br />fan beam.
<br />- Install nine plasters on existing floor of sun room
<br />approxim Plasters are concrete block filled
<br />otely 6' centers.
<br />solid.
<br />- Install double 2x8 pressure treated beam, north and south,
<br />on top of three rows of plasters. Center row of plasters will
<br />be 7-1/2" lower in height.
<br />- Install pressure treated 2x8 floor joist on 16" center
<br />perpendicular to beams. End of each joist to sit in joist
<br />hangers attached to east and west beams and will rest on
<br />top of center beam.
<br />- Install ?" pressure treated plywood on top of 2x8 joist.
<br />- Install 36" tongue and groove plywood on top of ?" plywood.
<br />- Re -frame five windows and one exterior door to new floor
<br />height approximately 20" up from existing floor; frame for
<br />A/C relocation.
<br />- Reinstall the five existing windows - three on west wall and
<br />two on north wall, west end.
<br />- Reinstall existing door and frame in north wall, east end.
<br />- Reinstall A/C unit north wall.
<br />- Relocate three wall outlets to new floor height and add one
<br />outlet for a total of
<br />- four - one each wall,
<br />- Install R-19 insulation in west and north walls.
<br />- Install moisture barrier on exterior of both walls.
<br />- Reinstall vinyl lop siding on both walls. Trim around windows
<br />and door as necessary for a water tight installation.
<br />- Install 112" drywoll floor to ceiling on all four interior walls;
<br />tape and finish drywall.
<br />- Install wood baseboard.
<br />- Point walls and trim completely.
<br />- Reinstall carpet on top of tongue and groove plywood.
<br />Exterior Door Sun Room
<br />Form, pour, and finish a 4x4 landing flush with floor of sun
<br />room. Stem wall on four sides of landing to be poured
<br />solid and have two #5 steel re -bars in each wall. Floor of
<br />landing to have wire mesh.
<br />From 4x4 landing on east side, form, pour, and finish a 4
<br />LF wide set of steps down to sidewalk.
<br />Install handroils on landing and both sides of steps.
<br />Roils are to match existing rails as closely as possible.
<br />Front Door
<br />- Demo existing rails on porch steps and sidewalk; save to
<br />reinstall.
<br />- Form, pour, and finish a cop on porch level with floor of
<br />home.
<br />- Form, pour, and finish a 4x19 LF romp from east side of
<br />landing toward the driveway. Finish ramp flush with new cop
<br />height and existing sidewalk.
<br />- Remove lost 4 LF of sidewalk at base of romp so that
<br />concrete pour will be 4" in thickness.
<br />- Reinstall hand roil on porch and romp that was removed.
<br />Carport
<br />- On east side of carport, remove plant bed.
<br />- From copping around plant bed west, back to carport, pour
<br />area solid and level with carport area approximately 3x27.
<br />110 ENCLOSED EXP B
<br />WIND - THIS PLAN HAS BEEN DESIGNED TO COMPLY WITH ALL PROVISIONS OFF
<br />FBC-2004 INCLUSIVE OF ASCE 7-05 WIND PROVISIONS FOR A NOMINAL DESIGN 3-SEC
<br />GUST OF 110 MPH. AS 15EFINED IN �ECTION 1609.2, DEFINITION (2), THIS STRUCTURE
<br />DOES MEET THE REQUIREMENTS FOR AN ENCLOSED BUILDING AND AS SUCH
<br />HAS BEEN DESIGNED NTH AN INTERNAL PRESSURE COEFFICIENT OF +18 AND -.'8,
<br />UNADJUSTED FOR ZONES 1,2, AND 3. DESIGN HAS UTILIZED A WIND IMPORTANCE
<br />FACTOR OF 1.00 FOR BUILDING CK-TAGORY 11 IN AN EXPOSURE B AREA AND COMPLIES
<br />WITH END SPEED MAPS AS ADOPTED BY COUNTY JURISDICTION.
<br />WINDOWS, DOORS, COMPONENTS
<br />DESIGN WIND PRESSURES
<br />ENCLOSED BUILDING
<br />DESIGN WIND PRESSURE (PSF)
<br />Zone
<br />Effective
<br />Basic Wind Speed
<br />Zone
<br />Effective
<br />Basic Wind Speed
<br />110 MPH 3-wc. Gust
<br />110 MPH
<br />3-sec. Gust
<br />4
<br />Wind Area
<br />5
<br />Wind Area
<br />SQ FT
<br />+
<br />-
<br />SQ FT
<br />+
<br /><10
<br />21.8
<br />23.6
<br /><10
<br />21.8
<br />29.1
<br />15
<br />21.3
<br />23.1
<br />is
<br />21.3
<br />33.6
<br />--1
<br />0_1
<br />20
<br />20.8
<br />22.6
<br />20
<br />20.8
<br />27.2
<br />25
<br />20.6
<br />22A
<br />25
<br />20.6
<br />26.8
<br />30
<br />20.4
<br />22.2
<br />30
<br />20.4
<br />26.4
<br />1
<br />1
<br />35
<br />20.2
<br />22.0
<br />35
<br />20.2
<br />26.0
<br />IT
<br />L0
<br />40
<br />20.0
<br />21.8
<br />40
<br />20.0
<br />25.5
<br />45
<br />19.7
<br />21.5
<br />45
<br />19.7
<br />25.1
<br />Li
<br />z
<br />LLJ
<br />z
<br />50
<br />19.5
<br />21.3
<br />50
<br />19.5
<br />24.6
<br />75
<br />19.0
<br />20.9
<br />75
<br />19.0
<br />23.6
<br />0
<br />E3
<br />N
<br />100
<br />j 18.5
<br />20.4
<br />N
<br />I 100
<br />18.5
<br />22.6
<br />GARAGE DOOR
<br />9'-O"WIDE 7'-O"HEIGHT
<br />19.1
<br />21.6
<br />16'-O"WIDE 7'-O"HEIGHT
<br />18.3
<br />20.4
<br />ROOF WIND ZONES
<br />DESIGN PRESSURES FOR THE ROOF ZONES ARE TAKEN FROM THE MOST
<br />CONSERVATIW CASE. (INCLUDING ROOF SLOPE, EFFECTIVE AREA AND
<br />ZONEI
<br />19.9
<br />21.8
<br />-
<br />ZONE2
<br />19.9::::l
<br />42.1
<br />OVERHANG COND11IONS)
<br />ZONE3
<br />19.9
<br />1 55.0
<br />NOTES!
<br />1. ANY WINDOW, ALL OR PART, WHICH IS WITHIN 6' OF A CORNER
<br />SHALL BE CONSIDERED ZONE 5 PER CHART ABOVE, ALL OTHER
<br />WINDOWS ARE CLASSIFIED IN ZONE 4.
<br />2. ROUND AREA DOWN TO THE LARGEST PRESSURE
<br />IN THE CHART ABOVE,
<br />- DESIGN PRESSURES ABOVE REPRESENT THE NET PRESSURE (SUM OF EXTERNAL AND
<br />INTERNAL PRESSURES) APPLIED NORMAL TO ALL SURFACES. COMPONENT MANUFACTURER
<br />SHALL USE THE HIGHER OF THE TWO NUMBERS FOR APPLICABLE SQUARE FOOTAGE
<br />5.05'
<br />SITE PLAN
<br />CODE REFERENCE NOTES
<br />ALL CONSTRUCTION SHALL COMPLY WTH CURRENTLY
<br />ADOPTED CODES, WHICH INCLUDE, BUT ARE NOT
<br />LIMITED TO:
<br />FLORIDA BUILDING CODE, 2004 EDITION.
<br />FLORIDA FIRE PREVENTION CODE, 2000 EDITION.
<br />NFPA LIFE SAFETY CODE, 2006 EDITION
<br />NFPA 1 UNIFORM FIRE CODE, FLORIDA 2005 EDITION
<br />FLORIDA STATUTE 633, WHICH INCLUDES. -
<br />STATE FIRE MARSHALL'S RULES AND
<br />REGULATIONS
<br />ALL LOCAL CODES AND ORDINANCES.
<br />TABLE OF CONTENT
<br />A1.0 SITE PLAN
<br />A2.0 EXISTING/ DEMOLITION PLAN
<br />A2.1 FLOOR PLAN
<br />A3.0 PRODUCT APPROVAL
<br />A3.1 PRODUCT APPROVAL
<br />PRODUCT APPROVAL SEE A3.0 AND A3.11 FOR DETAILS
<br />PRODUCT CATEGORY
<br />SUB CATEGORY
<br />MANUFACTURE
<br />STATE OF FLORIDA
<br />EXPIRATION
<br />APPORVAL NUMBER
<br />NUMBER
<br />ROOFING
<br />METAL ROOFING
<br />ELITE ALUMINUM
<br />FL15OO-R1
<br />01/11/07
<br />CORPORATION
<br />5.05' 5.05' 52.87'
<br />NEW HORIZONON BLVD,
<br />LEGAL DESCRIPTION
<br />LOTS 50 AND 51, GRAND HORIZONS PHASE ONE, AS PER PLAT
<br />THEREOF RECORDED IN PLAT BOOK 34, PAGES 99-102, PUBLIC
<br />RECORDS OF PASCO COUNTY, FLORIDA
<br />PARCEL #34-25-21-0090-00000-0500 AND
<br />34-25-21-0090-00000-0510
<br />10.57'
<br />SUBJECT TO RESTRICTIONS FILED IN OFFICIAL RECORD BOOK 3753,
<br />FIT
<br />J
<br />H
<br />G
<br />E
<br />Ic
<br />Chris
<br />A/
<br />V rren
<br />DRAFTING
<br />6226 GREENLEAF
<br />TAMPA, FLORIDA 33617
<br />PHONE 813.362.7415
<br />IERRA
<br />RESIDENTIAL
<br />CONSTRUCTION
<br />PAUL J. SIERRA CONSTRUCTION, INC.
<br />912 W. MARTIN LUTHER KING BLVD.
<br />TAMPA, FLORIDA 33603
<br />PHONE (813) 228-6661
<br />FAX (813) 223-5328
<br />REVIEW DATE
<br />Y�_Hll_
<br />GITYOF ZEFIH' LL§
<br />t_-)XAI`v",INER
<br />AI_T_'�, ORK SHALL CON �pi Y WTT�l ALL,
<br />'-'REVAILVING CODFS, FLORIDA BUILD!`-
<br />0 IC CODE A�'__�
<br />zDE, NATIONAL rLLLCTR
<br />0F,7E-?11yR11,ILLc O1PD1'NNNCES
<br />>
<br />J
<br />z
<br />00 .4t
<br />0
<br />LO
<br />UJ co
<br />(J 0 co
<br />Z N j
<br />0 UJ W U-
<br />z Q 0
<br />U)
<br />UJ _J
<br />W _J
<br />UJ DRAWN BY:
<br />0 Z Z CW
<br />>_
<br />DATE:
<br />11/07/07
<br />UJ LO
<br />�. LU U-)
<br />W REVISED:
<br />Cn N
<br />Al m0
<br />(4
<br />19 18 17
<br />16 15 14
<br />13 12 11
<br />10 9
<br />1001
<br />7
<br />5
<br />Ell
<br />3
<br />2