PLUMBING SPECIFICATIONS <br />SCOPE: THE CONTRACTOR SHALL VISIT THE SITE AND EXAMINE THE DRAWINGS AND SPECIFICATIONS BEFORE SUBMITTING A PROPOSAL. ALL WORK SHALL BE IN ACCORDANCE <br />WITH THE FLORIDA BUILDING CODES SEVENTH EDITION (2020), WITH AMENDMENTS, AND LOCAL CODES AND ORDINANCES. INSTALLATION SHALL COMPLY WITH THE CODE <br />REFERENCED STANDARDS SET BY NFPA, ASHRAE, ASPE, SMACNA, NEC AND UL. THE SYSTEMS, EQUIPMENT, DEVICES AND ACCESSORIES SHALL BE INSTALLED, FINISHED, <br />TESTED AND ADJUSTED FOR CONTINUOUS AND PROPER OPERATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR HIS WORK FITTING IN PLACE AND SHALL COORDINATE <br />WITH OTHER TRADES TO AVOID INTERFERENCE WITH THEIR WORK. THE INFORMATION GIVEN HEREIN AND ON THE DRAWINGS IS AS EXACT AS COULD BE SECURED, BUT ITS <br />EXTREME ACCURACY IS NOT GUARANTEED. THE DRAWINGS ARE DIAGRAMMATIC, INTENDED TO SHOW GENERAL ARRANGEMENT, CAPACITY AND LOCATION OF VARIOUS <br />COMPONENTS, EQUIPMENTS, AND DEVICES. IF WORK IS REQUIRED IN A MANNER TO MAKE IT IMPOSSIBLE TO PRODUCE FIRST CLASS WORK, OR SHOULD DISCREPANCIES <br />APPEAR AMOUNG THE CONTRACT DOCUMENTS, OR BETWEEN THE CONTRACT DOCUMENTS AND THE MANUFACTURER'S RECOMMENDATIONS,THE CONTRACTOR SHALL REQUEST <br />INTERPRETATION BEFORE PROCEDING WITH WORK. CONTRACTOR SHALL FURNISH AND INSTALL ALL MINOR ITEMS WHICH ARE OBVIOUSLY AND REASONABLY NECESSARY TO <br />COMPLETE THE INSTALLATION WHETHER OR NOT SPECIFIED IN THE DOCUMENTS. <br />REQUIRED COORDINATION: ALL WORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN DUCTS AND PIPING (INCLUDING DIVIDED DUCTS) AND TRANSITIONS <br />AROUND OBSTRUCTIONS SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER. <br />CONSTRUCTION PLANS: IN GENERAL, PLANS AND DIAGRAMS ARE SCHEMATIC ONLY AND SHOULD NOT BE SCALED. <br />REQUIRED ACCESS: CONTRACTOR SHALL ENSURE THAT ALL EQUIPMENT AND DEVICES THAT REQUIRE REPLACEMENT, SERVICING, ADJUSTING OR MAINTENANCE SHALL BE <br />LOCATED TO ALLOW EASY ACCESS AND SPACE FOR REMOVAL OF INTERNAL ASSMBLIES, IF REQUIRED. CONTRACTOR SHALL PROVIDE ACCESS PANELS WHERE REQUIRED TO <br />ALLOW ACCESS, EVEN IF NOT INDICATED ON THE DRAWINGS AT NO ADDITIONAL COST TO OWNER. <br />WIND RESISTANCE: ALL EQUIPMENT, APPLIANCE AND SUPPORTS LOCATED EXTERIOR OF THE FACILITY SHALL BE INSTALLED TO RESIST WIND LOADS AS DETAILED IN THE <br />BUILDING CODE. <br />CUTTING AND PATCHING: ALL OPENINGS AROUND DUCT OR PIPE PENETRATIONS THROUGH SMOKE OR FIRE RATED FLOORS, CEILINGS OR WALLS SHALL BE SEALED AIRTIGHT <br />WITH MATERIALS HAVING A RATING EQUAL TO THE MATERIAL OF THE WALL, CEILING OR FLOOR PENETRATED. <br />EQUIPMENT TAGS: ALL EQUIPMENT WILL HAVE A PERMANENTLY FIXED TAG CORRESPONDING TO THE EQUIPMENT TAG ON THE ENGINEER'S DRAWINGS. <br />FIRESTOPPING: UL APPROVED MATERIALS AND METHODS SHALL PROTECT THE PENETRATIONS OF FIRE AND/OR SMOKE RATED WALLS, CEILINGS OR FLOORS. THE RATING OF <br />THE FIRESTOPPING SHALL EQUAL THE RATING OF THE RATED ASSEMBLY. ALL INSULATION SHALL HAVE COMPOSITE FIRE AND SMOKE HAZARD RATINGS AS TESTED BY <br />PROCEDURE ASTM E-84, NFPA-225, UL-723 NOT EXCEEDING: <br />FLAME SPREAD 25 <br />SMOKE DEVELOPED 50 <br />FUEL DISTRIBUTED 50 <br />ACCESSORIES SUCH AS ADHESIVE, MASTIC, CEMENTS AND TAPES SHALL HAVE THE SAME COMPONENT RATING AS LISTED ABOVE. <br />SERVICE AND PERMITS: CONTRACTOR SHALL MAKE ALL ARRANGEMENTS WITH UTILITY COMPANIES FOR SERVICE AND CONNECTIONS AND SHALL PAY FOR PERMITS. <br />SHOP DRAWINGS: EACH TRADE SHALL PREPARE AND SUBMIT SHOP DRAWINGS IN ACCORDANCE WITH PROCEDURES OUTLINED IN DIVISION 1. RESPONSIBILITY FOR ERRORS OR <br />OMISSIONS IN THE SUBMITTALS SHALL NOT BE RELIEVED BY THE ARCHITECT'S OR ENGINEER'S REVIEW. ENGINEER'S PROCESSING WILL NOT CONSTITUTE A COMPLETE CHECK <br />BUT WILL INDICATE ONLY THAT A GENERAL METHOD OF CONSTRUCTION AND DETAILING IS SATISFACTORY. AT A MINIMUM SUBMITTALS SHALL INCLUDE FIXTURES, VALVES, <br />PIPING, INSULATION AND ACCESSORIES. <br />START-UP: CONTRACTOR SHALL STARTUP ALL EQUIPMENT AND FOLLOW THE MANUFACTURER'S START-UP PROCEDURES. <br />OPERATING AND MAINTENANCE DATA: SUBMIT THREE COPIES OF MANUFACTURER'S OPERATING AND MAINTENANCE INSTRUCTIONS AND SPARE PARTS LIST FOR EACH PIECE OF <br />EQUIPMENT. <br />SUPPLEMENTARY SUPPORTS: CONTRACTOR SHALL PROVIDE ALL SUPPLEMENTARY STEEL REQUIRED TO SUSPEND MECHANICAL EQUIPMENT AND MATERIALS, IN ORDER TO <br />PROVIDE A "VIBRATION- FREE" RIGID INSTALLATION. <br />DIELECTRIC UNIONS: PROVIDE DIELECTRIC UNIONS OR FLANGES AT CONNECTIONS OR CONTACT BETWEEN PIPES OF DISSIMILAR METALS. <br />MEDICAL GAS Z VACUUM PIPING: COMPRESSED AIR PIPING SHALL BE OIL -FREE TYPE-L COPPER IN ACCORDANCE WITH ASTM-B75 / ASTM-B819, AND IN ACCORDANCE WITH <br />NFPA-99 (2015 ED.). COMPRESSED AIR PIPING SHALL BE WRAPPED WITH SHURTAPE BRAND TAPE WHERE IN CONTACT WITH SOIL. VACUUM PIPING SHALL BE SCHEDULE <br />40-PVC WITH SOLVENT FITTINGS. <br />WATER PIPING: WATER PIPING SHALL BE CPVC TUBING. TUBING, FITTINGS AND CEMENT SHALL MEET ASTM D-2846, 100 PSI 0 180*17 CONTINUOUS RATING. CPVC TUBING <br />AND FITTINGS SHALL MEET 25/50 FLAME SPREAD/SMOKE DEVELOPED REQUIREMENTS FOR PLENUMS. CONTRACTOR SHALL INSTALL CPVC IN ACCORDANCE WITH <br />MANUFACTURER'S INSTRUCTIONS. CONTRACTOR SHALL PROVIDE FOR EXPANSION AND CONTRACTION OF TUBING. TUBING SHALL BE SLEEVED AT PENETRATION OF CONCRETE <br />SLABS OR WALLS. CPVC TUBING SHALL BE BFGOODRICH FLOWGUARD GOLD OR APPROVED EQUAL. INSTALL PIPE SUPPORTS AT 3-FOOT INTERVALS FOR SIZES 1" OR <br />SMALLER; INSTALL PIPE SUPPORTS AT 4-FOOT INTERVALS FOR 1-1/4" AND LARGER. <br />WATER HAMMER ARRESTORS: INSTALL WATER HAMMER ARRESTERS AT EACH HOT AND COLD FIXTURE SUPPLY. <br />EXPOSED PIPING: EXPOSED PIPING SHALL BE POLISHED CHROMIUM ON EITHER BRASS OR BRONZE. PROVIDE ADA INSULATED WATER AND WASTE LINE COVERINGS FOR WALL <br />HUNG SINKS AND LAVATORIES. <br />VALVES: ALL VALVES SHALL HAVE A MINIMUM OF 125 PSIG WORKING PRESSURE. VALVES AND COCKS MAY NOT BE INDICATED IN EVERY INSTANCE ON THE DRAWINGS, BUT <br />WHETHER OR NOT SHOWN, ALL VALVES, COCKS AND CHECK VALVES NECESSARY FOR THE PROPER OPERATION OF THE SYSTEM SHALL BE FURNISHED AND INSTALLED. <br />INSTALL ISOLATION/SHUT-OFF VALVES AT ALL MAIN RISERS, AND MAIN BRANCH TAKEOFFS. INSTALL ISOLATION/SHUT-OFF VALVES ON EACH INLET AND OUTLET OF EACH <br />PIECE OF EQUIPMENT. PROVIDE A FLANGE OR UNION BETWEEN THE VALVE AND THE EQUIPMENT TO PERMIT DISCONNECTION, REMOVAL AND SERVICE. <br />STERILIZATION OF DOMESTIC WATER SYSTEM: THE ENTIRE DOMESTIC WATER DISTRIBUTION SYSTEM SHALL BE THOROUGHLY STERILIZED AS REQUIRED BY THE HEALTH <br />AUTHORITY OR WATER PURVEYOR HAVING JURISDICTION, OR IN THE ABSENCE OF A PRESCRIBED METHOD, THE PROCEDURE DESCRIBED IN EITHER AWWA C651 OR AWWA C652, <br />OR AS DESCRIBED IN SECTION 610 FBC-P. <br />VENTING: THE STACKS SHALL BE EXTENDED THROUGH ROOF OF BUILDING TO POINTS NOT LESS THAN 12" ABOVE ROOF. VENTS SHALL BE OFFSET AS REQUIRED TO <br />PENETRATE ROOFS AT LEAST 3 FEET FROM THE RIDGE OR EDGE OF BUILDING AND 10 FEET FROM ANY FRESH AIR INTAKE OR OPERABLE WINDOW OR DOOR. <br />SANITARY, <br />WASTE, AND VENT PIPING: <br />ALL BURIED AND UNBURIED <br />PIPING AND FITTINGS SHALL BE SCHEDULE 40 PVC-DWV. (SOLID CORE) SLOPE OF SANITARY OR DRAINAGE <br />PIPING 2-1/2" <br />AND SMALLER SHALL <br />BE A MINIMUM OF 1/4" PER <br />FOOT; PIPING 3" AND LARGER SHALL BE SLOPED A MINIMUM OF 1/8" PER FOOT. CLEANOUTS WILL BE <br />LOCATED <br />NOT MORE THAN 100 FEET <br />APART AND AT EACH CHANGE <br />OF DIRECTION GREATER THAN 45* ALONG THE HORIZONTAL DRAIN. CLEANOUTS SHALL BE INSTALLED AT <br />BASE OF <br />EACH STACK. CONCEALED <br />CLEANOUTS SHALL HAVE CAST <br />BRASS CHROMIUM PLATED FLAT ACCESS COVER PLATE. <br />FLOOR DRAINS/SINKS: FLOOR DRAINS SHALL BE CAST IRON AND ADJUSTABLE TO ACCOMMODATE THE FINISHED FLOOR. FLOOR SINKS SHALL HAVE AN ACID -RESISTANT <br />ENAMELED INTERIOR. STRAINERS SHALL BE PROVIDED WITH BARRIER -TYPE TRAP SEAL PROTECTION (ASSE 1072) AND FLASHING FLANGE OR CLAMP, UNLESS OTHERWISE <br />INDICATED. <br />DOMESTIC WATER HEATERS (ELECTRIC): WATER HEATER SHALL BE CERTIFIED BY THE NATIONAL SANITATION FOUNDATION & UL-LISTED. UNITS SHALL BE EQUIPPED WITH <br />CODE -APPROVED TEMPERATURE AND PRESSURE RELIEF VALVES. TANKS SHALL BE GLASS -LINED AND SHALL HAVE MANUFACTURIER'S STANDARD FIVE-YEAR WARRANTY. <br />PLUMBING FIXTURES AND TRIM: PLUMBING FIXTURES SHALL BE FURNISHED AND INSTALLED IN A NEAT AND WORKMANLIKE MANNER WITH PROPER CONNECTIONS TO SUPPLY <br />AND DRAINAGE PIPING. ALL FIXTURES SHALL BE FREE OF FLAWS AND DEFECTS OF ANY SORT IN MATERIAL AND WORKMANSHIP AND SHALL OPERATE PERFECTLY WHEN <br />INSTALLED IN ACCORDANCE WITH MANUFACTURER'S DIRECTIONS. CONTRACTOR SHALL PROVIDE ROUGH -IN, AND SHALL CONNECT ALL FIXTURES TO THE PLUMBING SYSTEMS. <br />ALL FIXTURES TO BE PROVIDED WITH CHROME -PLATED SUPPLIES AND STOPS. PROVIDE 17 GAUGE CHROME -PLATED BRASS TRAPS FOR ALL FIXTURES WITHOUT INTEGRAL <br />TRAPS. PROVIDE CONCEALED ARM CARRIERS AND SUPPORTS FOR ALL FIXTURES REQUIRING SAME. <br />PIPE INSULATION: INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. SEAL <br />ALL JOINTS, BREAKS, TEARS AND PENETRATIONS WITH FIRE RETARDENT, VAPOR BARRIER MASTIC. COVER VALVES, FITTINGS AND SIMILAR ITEMS IN EACH PIPING SYSTEMS. <br />INSULATE ALL DOMESTIC HOT WATER AND INTERIOR STORM PIPE WITH 1" THICK FIBERGLASS SECTIONAL PIPE COVERING WITH CANVAS JACKET OR ARMAFLEX AP (ASTM E-84). <br />PIPE INSULATION: INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. SEAL <br />ALL JOINTS, BREAKS, TEARS AND PENETRATIONS WITH FIRE RETARDENT, VAPOR BARRIER MASTIC. COVER VALVES, FITTINGS AND SIMILAR ITEMS IN EACH PIPING SYSTEMS. <br />INSULATE ALL DOMESTIC HOT WATER AND ALL PIPING EXPOSED IN RESIDENCE UTILITY ROOMS WITH 1" THICK PLENUM RATED ARMAFLEX AP SECTIONAL PIPE COVERING (ASTM <br />E-84). <br />TESTING: TEST ALL WASTE AND VENT PIPING FOR A PERIOD OF NOT LESS THAN 8 HOURS BY CAPPING OR PLUGGING. ALL JOINTS TO A LEVEL OF THE HIGHEST FIXTURE OR <br />FITTINGS. FILLING THE SYSTEM WITH WATER, AND OBSERVING FOR LEAKS. TEST WATER PIPING AT 100 PSIG FOR A PERIOD OF 8 HOURS, OBSERVING FOR ANY VISIBLE <br />LEAKS. TEST PIPING AGAIN WITH FIXTURES INSTALLED. REPAIR ANY LEAKS FOUND BY REMAKING JOINT. DO NOT USE CAULKING OR SIMILAR METHODS TO CORRECT LEAKS. <br />UPON REPAIRING ANY LEAKS FOUND. AGAIN TEST THAT PORTION OF THE SYSTEM AS DESCRIBED ABOVE. <br />EQUIPMENT FURNISHED BY OTHERS: WHERE SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL MAKE ALL PIPING CONNECTIONS TO EQUIPMENT FURNISHED BY OTHERS. <br />THIS WORK SHALL INCLUDE FURNISHING AND INSTALLATION OF ALL WATER AND DRAIN PIPING. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH RECOMMENDATIONS OF <br />EQUIPMENT MANUFACTURER. <br />GUARANTEE: THE ONE-YEAR GUARANTEE PERIOD SHALL NOT START UNTIL THE PROJECT IS FULLY COMPLETED AND THE CONTRACTOR HAS RECEIVED THE FINAL PAYMENT AND <br />CERTIFICATION OF COMPLETION. ALL EQUIPMENT AND ALL WORK SHALL BE FULLY GUARANTEED, PARTS AND LABOR, FOR ONE YEAR FROM THE DATE OF THE CERTIFICATE OF <br />COMPLETION. REPAIRS MADE DURING THIS PEROID MUST BE FULLY GUARANTEED FOR AN ADDITIONAL ONE YEAR PERIOD FROM THE DATE OF REPAIRS. IN ADDITION, THE <br />CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY DAMAGE TO THE BUILDING, AND ITS CONTENTS OR OTHER EQUIPMENT, CAUSED BY DEFECTS OR IMPROPER <br />INSTALLATION OF EQUIPMENT OR MATERIAL INSTALLED. <br />SUBSTITUTIONS: CONTRACTOR SHALL PAY FOR ANY AND ALL ADDED COSTS ASSOCIATED WITH ANY SUBSTITUTION, INCLUDING SUBSTITUTIONS THAT REQUIRE CHANGES TO THE <br />OTHER BUILDING COMPONENTS, SUCH AS ELECTRICAL, STRUCTURAL REINFORCING, CEILINGS, WALLS, ROOFS, ETC. THIS WILL INCLUDE ANY ENGINEERING/ARCHITECTURAL <br />RE -DESIGN COSTS AS A RESULT OF SAID SUBSTITUTION. THESE COSTS SHALL NOT BE BORNE BY THE OWNER, ARCHITECT, NOR ENGINEER, REGARDLESS OF ACCEPTABILITY <br />OF SUBSTITUTION. ENGINEER RESERVES THE RIGHT TO ACCEPT OR DENY ANY SUBSTITUTION THAT HE DOES NOT DEEM TO BE EQUIVALENT, AND CONTRACTOR SHALL <br />PROVIDE SPECIFIED OR EQUIVALENT MATERIALS/EQUIPMENT AT NO ADDITIONAL COST TO OWNER, SHOULD A SUBSTITUTION BE DENIED. <br />FIXTURE & CONNECTION SCHEDULE <br />BRANCH SIZE <br />I <br />FIXTURE <br />TAG <br />MANUFACTURER/MODEL <br />REMARKS <br />DRAINAGE <br />WATE <br />WASTE <br />VENT <br />COLD <br />HOT <br />WATER CLOSET <br />WC-11 <br />3" <br />2" <br />1/2" <br />AMERICAN STANDARD CADET #2467.016 <br />PRESSURE -ASSISTED TANK, VITREOUS CHINA, ELONGATED BOWL, SIPHON JET, FLOOR <br />(HANDICAPPED) <br />SEAT: BEMIS # 1655SSCT <br />MOUNTED. FLUSH HANDLE ON WIDE SIDE OF STALL. 16-1/2" BOWL RIM HEIGHT, & <br />FULLY GLAZED 2-1/8" TRAPWAY. SOLID WHITE PLASTIC SEAT WITH OPEN FRONT & <br />SELF-SUSTAINING CHECK HINGES. ALSO, PROVIDE 3/8" SUPPLY AND STOP, CLOSET <br />FLANGE, WAX SEAL RING, NUTS, BOLTS AND WASHERS AS REQUIRED. <br />LAVATORY <br />LAV- 1 <br />2" <br />2" <br />1/2" <br />1/2" <br />AMERICAN STANDARD LUCERNE #0355.012 <br />LAVATORY: 20"x`18", VITREOUS CHINA, WITH FAUCET LEDGE AND INTEGRAL <br />(ADA) <br />DELTA SINGLE LEVER FAUCET #523LF-HGMHDF <br />OVERFLOW. PROVIDE ARM CHAIR FLOOR CARRIER. SINGLE LEVER FAUCET <br />WITH 4" CENTERS, O.5-GPM AERATOR, & GRID DRAIN ASSEMBLY. PROVIDE <br />MIXING VALVE: LAWLER # TMM-1070 <br />ASSE 1070 LISTED MIXING VALVE SET TO 109*F, TAILPIECE, P-TRAP, SUPPLY <br />CARRIER: ZURN #Z1231 <br />& STOPS. INSULATE EXPOSED PIPING WITH TRUEBRO LAV GUARD KIT. <br />DRINKING FOUNTAIN <br />EWC-1 <br />2" <br />2 <br />1/2" <br />-- <br />ELKAY # EZSTL8C <br />DRINKING FOUNTAIN: ELECTRIC WATER COOLER, 2-STATION, <br />(HI-LO = ADA) <br />CARRIER: ZURN #Z1225 <br />STAINLESS STEEL BASINS, WITH MANIFOLD WATER/SANITARY CONNECTIONS, <br />FLOOR CARRIER. 120-V/1-PH. DISCONNECT BY ELECTRICIAN <br />MOP SINK <br />MS-1 <br />2" <br />2" <br />1/2" <br />1/2" <br />FIAT # MSB 2424 <br />MOP SINK: MOLDED PLASTIC, 10" LIP EDGE, 2" DRAIN & BASKET STRAINER. <br />ACCESSORIES: FIAT #830AA, 832AA & 889CC <br />PROVIDE WALL MOUNTED FAUCET WITH BRACKET ARM & PAIL HOOK, MOP <br />HANGER, HOSE AND HOSE BRACKET. <br />RECIRC PUMP <br />RP-1 <br />1/2" <br />TACO 003 <br />HOT WATER RECIRCULATION PUMP. 115 V, 0.43 AMP, 1/40 HP, 1/2" CONNECTIONS, <br />5 FT HEAD. PROVIDE BALANCE VALVE, AQUASTAT & 7-DAY PROGRAMMABLE TIMER. <br />ICE BOX <br />IB-1 <br />-- <br />1/2" <br />-- <br />GUY GRAY # BIM875 <br />ICE MAKER BOX: GALVANIZED STEEL, 18 GA. FACEPLATE, 1/4-TURN STOP, <br />COMBINATION MIP OR SWEAT CONNECTION. PROVIDE WATER HAMMER ARRESTOR. <br />PROVIDE ASSE 1022 CHECK VALVE AFTER STOP FOR VISUAL INDICATION FOR FAILURE. <br />EXAM SINK <br />ES-1 <br />2" <br />2" <br />1/2" <br />1/2" <br />DAYTON # D11515 <br />COUNTERTOP MOUNT, 12"XlO"X5"BOWL, STAINLESS STEEL. PROVIDE STOPS, <br />ZURN # Z812B4-3F <br />SUPPLIES, TRAP, ETC., TO MAKE A COMPLETE INSTALLATION. <br />FAUCET: DUAL WRIST BLADE HANDLES, DECK MOUNT GOOSENECK FAUCET WITH <br />GRID STRAINER, & 0.5GPM AERATOR. <br />HAND SINK <br />S-1 <br />2- <br />2" <br />1/2" <br />1/2" <br />JUST MFG # WHL-14-S <br />WALL MOUNT, ROUND BOWL, STAINLESS STEEL. PROVIDE STOPS, SUPPLIES, TRAP, <br />ETC., TO MAKE A COMPLETE INSTALLATION. <br />FAUCET: SENSOR OPERATED, 120-VOLT WALL PLUG. <br />SINK <br />LS-1 <br />2" <br />2" <br />1/2" <br />1/2" <br />DAYTON ELITE # D12521 <br />COUNTER MOUNT, 1-COMPARTMENT STAINLESS STEEL SINK, COATED UNDERSIDE <br />FAUCET: ZURN #Z812C4-3F <br />SELF -RIMMING, 6" DEEP, 2" DRAIN & BASKET STRAINER, WITH FAUCET HOLES ON <br />GUARDIAN # G1200 EYEWASH <br />4 IN. CENTERS. FAUCET: GOOSENECK FAUCET WITH 4" WRIST BLADES HANDLES. <br />PROVIDE STOPS, SUPPLIES, TRAP, ETC., TO MAKE A COMPLETE INSTALLATION. <br />MIXING VALVE: LAWLER # 911E/F <br />PROVIDE UNDER COUNTER ASSE 1071 MIXING VALVE SET TO 95*F. PROVIDE <br />FAUCET MOUNTED EYEWASH WITH SINGLE MOTION CONTROL. <br />BREAK SINK <br />BS-1 <br />2" <br />2" <br />1/2" <br />1/2" <br />DAYTON ELITE # D12521 <br />SINK: 25"X21"; 1-COMPARTMENT STAINLESS STEEL, COATED UNDERSIDE <br />FAUCET: ZURN # Z87lC4-XL <br />SELF -RIMMING, 2" DRAIN & BASKET STRAINER, WITH TWO FAUCET HOLE. <br />8"GOOSENECK FAUCET, 4;;WRISTBLADE HANDLE. PROVIDE STOPS, SUPPLIES, TRAP, <br />ETC., TO MAKE A COMPLETE INSTALLATION. <br />FLOOR DRAIN <br />FD-1 <br />3' <br />2" <br />�7 '7 -7 77 v � 7, 7 T, 77 v <br />ZURN # Z415E <br />6URA-COATED CAST IRON-66DY, '6"D'lAa�rER'13_R6`NZ_E -AD-JU-STA-BL-E-ST-RAI-NE-R-WI-TH� <br />ZURN # Z1072 <br />FUNNEL. PROVIDE 4" DEEP TRAP AND TRAP GUARD (ASSE 1072 CERTIFIED). <br />WALL CLEANOUT <br />WCO <br />SEE <br />ZURN 0 Z1468 <br />WALL CLEANOUT - ROUND STAINLESS STEEL WALL ACCESS COVER <br />PLANI <br />WITH SECURING SCREW AND BRONZE RAISED HEX HEAD PLUG. <br />I <br />PLUMBING LEGEND <br />DESCRIPTION <br />ABBREV. <br />SYMBOL <br />SANITARY PIPING <br />SAN <br />VENT PIPING <br />V <br />------------------ <br />DOMESTIC COLD WATER <br />CW <br />DOMESTIC HOT WATER <br />HW <br />COMPRESSED AIR PIPING <br />CA <br />---CA----- <br />VACUUM PIPING <br />VAC <br />----VAC----- <br />FILTERED WATER PIPING <br />FW <br />— - -FW- <br />NITROUS PIPING <br />N <br />_N <br />OXYGEN PIPING <br />Ox <br />Ox <br />BALL/ISOLATION VALVE <br />BV <br />__d)l_ <br />DUAL -CHECK BACKFLOW <br />N <br />PREVENTER <br />GRADE CLEAN OUT <br />COTG <br />COTG <br />WALL CLEAN OUT <br />WCO <br />Wco 1! 0 <br />FLOOR CLEAN OUT <br />FCO <br />FCO 0— <br />PIPE TURNING UP <br />0— - <br />PIPE TURNING DOWN <br />C <br />CAPPED PIPING <br />Er— - — <br />TYPICAL ITEM <br />TYP <br />CONNECTION BETWEEN <br />NEW & EXISTING <br />EXISTING <br />(E) <br />NEW <br />(N) <br />I BALANCE VALVE <br />BV <br />NOTE ON EXISTING UTILITIES: <br />CONTRACTOR SHALL FIELD VERIFY LOCATIONS & INVERTS <br />OF ALL EXISTING UTILITY MAINS INSIDE BUILDING (I.E. <br />SEWER, GAS, DOMESTIC WATER, ETC.) PRIOR TO ANY <br />DEMOLITION OR CONSTRUCTION. ADVISE ENGINEER OF <br />ANY DISCREPANCIES BEFORE PROCEEDING ANY FURTHER. <br />** CCTV VIDEO CAMERA INVESTIGATION REQUIRED BY PLUMBER <br />(PRIOR TO ANY WORK) TO VERIFY INVERT ADEQUATE AT MOST <br />REMOTE AREA OF NEW SANITARY UNDERGROUND CONNECTION. <br />NOTIFY ENGINEER OF RESULTS OF CAMERA WORK. <br />IALL ROOF DRAINAGE IS EXISTING TO REMAIN. I <br />NOTE TO CONTRACTOR <br />ON EXISTING CONDITIONS: <br />CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND <br />SURVEY ALL EXISTING CONDITIONS AND EQUIPMENT <br />PRIOR TO SUBMITTING BID FOR WORK REQUIRED BY <br />THESE DOCUMENTS. THIS INCLUDES ABOVE THE <br />CEILING AND ON TOP OF THE ROOF. <br />2. CONTRACTOR SHALL REFER TO AND READ THROUGH <br />ALL OF THE "CONTRACTOR'S SCOPE OF WORK" AS <br />DEFINED IN THE BID SPECIFICATIONS AND DOCUMENTS <br />AS PART OF THE BID PROCESS. <br />3. IF AT ANY TIME,- THERE IS DISCREPANCY BETWEEN THE <br />PLANS & SPECS, OR CONFUSION /CONCERN OVER <br />REQUIRED WORK, CONTRACTOR SHALL IMMEDIATELY <br />NOTIFY ARCHITECT, ENGINEER, &/OR OWNER AND GET <br />DIRECTION BEFORE PROCEEDING WITH WORK IN <br />QUESTION. <br />4. FOR ALL NEW ROOF PENETRATIONS, CONTRACTOR <br />SHALL INCLUDE IN HIS BID THE COST TO HIRE THE <br />ROOFING FIRM HOLDING THE WARRANTY TO PROVIDE <br />ROOF PENETRATIONS. <br />5. FOR ALL EXISTING EQUIPMENT TO BE RE -LOCATED <br />&/OR RE -USED, CONTRACTOR SHALL BE RESPONSIBLE <br />FOR DISCONNECTION, SAFE STORAGE, & <br />RE -CONNECTION OF SAID EQUIPMENT COMPLETELY. <br />6. FOR ALL EXISTING EQUIPMENT TO BE DEMOLISHED (I.E. <br />DEMO) CONTRACTOR SHALL BE RESPONSIBLE FOR <br />DISCONNECTION, REMOVAL, & DISPOSAL OFF -SITE PER <br />CODE, OF SAID EQUIPMENT COMPLETELY. <br />STEPANEK-L <br />ANDASSOCIATES <br />k9r,-7 TWrl Vr OAKS WAY, SUITE 103 <br />WESLEY CHAPEL, FL 33544 <br />PH (813) 991-1248 <br />REGISTRY # 8397 21-143 <br />6 <br />c: <br />(0 <br />Q) 00 <br />Z M_j <br />Z C. LL <br />E <br />co C.0 <br />�_ (0 <br />c, <br />00 0 <br />CO <br />0) <br />0 <br />Job Number <br />�_-\N D <br />No 56189 <br />STATE A <br />R <br />ON A <br />I, I I I I i <br />[a <br />MATTHEW D. LEWIS, P.E. FL LIC#56189 <br />