ARCHITECTURAL SPECIFICATIONS <br />NOTE: NOT ALL ITEMS ARE APPLICABLE TO THIS PROJECT <br />A. TERMITE CONTROL <br />USE AN EMULSIBLE CONCENTRATE INSECTICIDE FOR DILUTION WITH <br />WATER SPECIFICALLY FORMULATED TO PREVENT INFESTATION BY <br />TERMITES. FUEL OIL WILL NOT BE PERMITTED AS A DIWENT. PROVIDE <br />A WORKI�G SOLUTION OF ONE OF THE FOLLOWING CHEMICAL R EMENTS <br />AND COWENTRATION& <br />PRODUCTS <br />DURSBAN TC AS RECOMMENDED BY MANUFACTURER <br />ALDRIN: 0.596 IN WATER EMUL-90N <br />DELDRN: 05% IN WATER EMULSION <br />HEPTACHLOR 05% IN WATER EMULSION <br />OTHER SOLUTIONS MAY BE USED AS RECOMMENDED BY APPLICATOR <br />AND IF ACCEPTABLE TO ARCHITECT AND LOCAL GOVERNING <br />AUTHORITES. USE ONLY SOL TFEATMENT SOLUTIONS WHICH ARE NOT <br />INJURIOUS TO PLANTING, <br />It 9 ;11 <br />CONTRACTOR SHALL PROVIDE A PERMANENT SIGN NEAR EXJSTI% OR <br />NEW WATER HEATER OR ELECTRICAL PANFI WHICH IDENTIFIES TERMITE <br />TREATMENT PROVIDER PRODUCT USED, TIME AND DATE OF THE <br />TREATMENT SITE LOCATION, AREA TREATED CHEMICAL USED PERCENT <br />CONCENTRATION AND NUMBER OF GALLONS USED TO ESTABLISH A <br />VERIFLA&E RECORD OF PROTECTIVE TREATMENT <br />CLEARANCE BETWEEN EXTERIOR WALL COVERINGS AND FINAL EARTH <br />ON THE EXTEIROR OF TI-E BUILDI% SHALL NOT BE LESS THAN 6 INCHES <br />IN ORDER TO PROVIDE TERMITE INSPECTION <br />CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST <br />T-0' AWAY FROM BUILDNG SIDE WALLS <br />INITIAL TREATMENT OF TERMITE P0634W AND PROTECTION SHALL <br />BE DONE AFTER ALL EXCAVATION AND BACKFILL IS COMPLETE <br />COMPLY WITH FBC SECTION 1816.1.1 <br />SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED <br />INCLUDING SPACES BOXED OR FORIVIED <br />BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION <br />HALL BE M%E H PERMANENT METAL OR PLASTIC <br />W <br />WpSJUMSENT PORIVIS T"BE OF A SIZE AND DEPTH THAT WILL <br />ELIMINATE THE DISTURBANCE OF SOL AFTER INITIAL SOIL TREATMENT <br />REMOVE ALL CONCRETE OVERPOUR AND MORTAR ALONG THE <br />FOIJINDATION PERIMETER PRIOR TO EXTERIOR TERMITE SOL TREATMENT <br />CHEMICALLY TREATED SOIL FOR SUBTERRANEAN TERMITES SHALL BE <br />PROTECTED WITH A MINIMUM 6 MIL VAPOR RETARDER TO PROTECT <br />AGAINST RAINFALL DILUTOR RETREATIVIENT SHALL BE REQUIRED IF <br />RAINFALL OR DILUTION OF CHEIVICAL OCCURS PF40R TO SOL PROTECTOR <br />ALL BUILDINGS SHALL HAVE PRE -CONSTRUCTION TREATMENT AND <br />PROTECTION AGAINST SUBTERRANEAN TERMFrES LICENSED PEST <br />CONTROL APPLICATOR SHALL ISSUE A CERTIFICATE OF COMPLIANCE TO <br />THE BUILDING DEPARTMENT WITH THE FOLLOWING STATEMENT: <br />M-E BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE <br />PREVENTION OF SUBTERRANEAN TERMITES TREATMENT IS IN ACCORDANCE <br />WIT�&IES <br />OF UL* LAWS ESTABLISHED BY NE FLORIDA DEPARTMENT <br />AND C04SUMER SERVICER" <br />GC SHALL REMOVE ALL LOOSE WOOD AND FILL FROM BELOW AND <br />WITHIN T-0" OF THE BUILDING, INCLUDING \A= STAKES, FORMWORK, <br />TRAP BOXES, SHORWA OR OTHER CELLULOSE CONTANNG MATERIAL <br />NO WOOD, VEGETATION STUMPS� DEAD ROOTS, CARDBOARID, TRASH, <br />OR OTHER CELLULOSE -CONTAINING MATERIAL SHALL BE BURIED ON THE <br />BUILDING LOT WITHIN 15 FT. OF ANY EXISTING OR PROPOSED BULDING <br />STRUCTURE <br />AN EXTERIOR VERTICAL CHEMICAL BARRIER SHALL BE INSTALLED AFTER <br />CONSTRUCTION IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION, <br />ANY SOIL DISTURBED AFTER THE VERTICAL BARRIER IS APPLIED SHALL <br />BE RETREATED. <br />SOL TREATMENT SHALL BE APPLIED UNDER ALL EXTEROR CONCRETE <br />OR GRADE WITHIN T-O' OF THE STRUCTURE SIDEWALLS, <br />B. CONCRETE <br />PRODUCTS <br />CONCRETE MIX UNLESS SPECIFIED ON STRUCTURAL DOCUMENT& <br />PROVIDE CONCRETE TO THE FOLLOWING MIX DESSIGNI: <br />COMPRESSIVE STRENGTH (28 DAY) MINIMUM 3000 P.SI. <br />MAXIMUM 2196 FLY ASH OF CEMENT <br />EXAMINATION <br />VERIFY COMPACTED SUBGRADE IS ACCEPTABLE AND READY TO <br />SUPPORT PAVING <br />VERIFY GRADIENTS AND ELEVATIONS OF THE BASE ARE CORRECT <br />Pf:EPARATION <br />MOISTEN BASE TO MINIMIZE ABSORPTION OF WATER FROM FRESH <br />COW -FETE COAT SURFACES OF ALL FRAMES WITH OIL TO <br />PREVENT BOND WITH CONCRETE <br />NOTIFY ARCHITECT MINIMUM 24 HOURS PRIOR TO COMMENCEMENT <br />OF CONCFETIWG OPERATIONS <br />EXECUTION <br />ENSURE REINFORCEMENT, INSERTS, EMBEDED PARTS, FORMED <br />JOINTS ARE NOT DISTURBED DURING CONCRETE PLACEMENT <br />PLACE C)ONICRETE CONTINUOUSLY BETWEEN PREDETERMINED <br />CONSTRUCTION JOINTS DO NOT BREAK OR NTERRUPT <br />SUCCESSIVE POURS SUCH THAT COLD JOINTS OCCUR <br />JOINTS <br />PLACE CONTROL JOINTS AT 10 FOOT INTERVALS (LON) <br />PLACE JOINT FILLER BETWEEN PAVING COMPONENTS AND BUILDING <br />(DR OTHER APPURTENANCES <br />PROVIDE SAW JOINTS AT 5 FEET INTERVALS IN SIDEWALKS <br />SAW CUT CONTRACTION JOINTS 31*6 INCH WIDE AT AN OPTIMUM 11ME <br />UP TO 24 HOURS AFTER FINISHING. CUT 1/4 INTO DEPTH OF SLAB <br />FINISHIW-A <br />STEEL TROWEL <br />PROTECTION <br />IMMEDIATELY AFTER PLACEMENT PROTECT CONCRETE FROM <br />PREMATURE DRYING, EXCESSIVE HOT OR COLD TEMPERATURES, <br />AND MECHANICAL INJURY <br />C. COLD FORMED METAL FRAMING <br />PRODUCTS/MANUFACTURERS <br />DALE INDUSTRIES, INC <br />DIETRICH INDUSTRIES, INC <br />ALLSTEEL & GYPSUM PRODUCTS, INC <br />FRAMING MATERIALS <br />STUDS ASTM C955 FORMED TO CHANNEI SHAPE, SOLID WEB <br />GUAGES AS INDICATED ON DRAWWSS, I INCH FACE AND <br />3 5/8 OR 6 IN. DEEP TRACK, FORMED STEEL, CHANNEL <br />SHAPED, SAME WIDTH AS STUDS, SOLID WER 20 GAGE THICK <br />UNLESS OTHERWISE SPECARED ON PLANS) <br />ACCESSORIES <br />BRACIWA FURRIWA BRIDGING, PLATES GUSSL7S AND CUPS FORMED <br />SHEET STEEL, THICKNESS DETERVINED FOR CONDITIONS <br />ENCOUNTERED <br />FASTENERS <br />SELF DRILLM SELF TAPPING SCREWS, BOLTS, NUTS AND WASHERS, <br />ASTIVI A123, HOT DIP GALVANIZED TO 125 OZ/90 FT <br />ANCHORAGE DEVICES POWER ACTUATED AND DRILLED EXP BOLTS <br />WELDING; N CONFORMANCE WITH AWS D11 AND AWS D13 <br />FABRICATION <br />FABRICATE ASSEMBLIES OF FRAMED SECTIONS OF SIZES AND <br />PROFILES REQUIRED WITH FRAMING MEMBERS FITTED, <br />REINFORCED, AND BRACED TO SUIT DESIGN MQUIREI`V�NITS <br />FINISHES <br />STUDS GALVANIZE TO G90 COATING CLASS <br />TRACKS AND HEADEFe GALVANIZE TO G90 COATING CLASS <br />BRAO�4 FURRINGA BRIDGING, PLATES, GUSSETS AND CUPS, SAME <br />FINISH AS FRAMING MEMBERS <br />D. BUILDING INSULATION <br />PRODUCTS/MANUFACTURERS <br />CERTAINTEED CORPORATION <br />OWENS-CORNING FIBERGLASS CORPORATION <br />ATLAS ENERGY PRODUCTS <br />CELOTE)( ROOFING PRODUCTS <br />INSULATINGG MATERIALS <br />RIGID BOARD PREFORMED UNITS <br />SOUND ATTENUATION BLANKETS: ASTM C 665� TYPE 1, <br />UNFACED MINERAL FIBER INSULATION 3 IN. THICK MIN. <br />STC-50 MIR AT ALL INTERIOR PARTITIONS <br />SPRAY FOAM ICYNENE INSULATION (R-30 MIN) <br />BATT INSULATION: ASTIVI C665, PREFORMED GLASS FIBER BATT, <br />FRIC-nON FIT, R-VALUE OF 11, BATT SIZE 16 X 48 INCH, UNFACED, <br />FLAME/SMOKE PROPERTIES 25/25 IN ACCORDANCE WITH ASTM E84 <br />POLYISOCYANURATE ROOF INSULATION: CLOSED CELL TYPE� <br />2 LB/CU FT., FACTORY APPLIED FIBERGLASS FACING TYPE Z <br />FLAME SPREAD 25, AND AGED R OF 30 MIN <br />PREPARATION <br />CLEAN SUBSTRATE OF SUBSTANCES HARMFUL TO <br />INSULATION AND INTERFERING WITH ATTACHMENT <br />INSTALLATION <br />INSTALL PER MANUFACTURER'S RECOMMENDATIONS <br />BOND UNITS TO SUBSTRATE WITH ADHESIVE OR MECHANICAL <br />ANCHORAGE TO PROVIDE PERMANENT PLACEMENT OF UNITS <br />INSTALL MINERAL FIBER BLANKETS IN CAVITIES BY <br />FRICTION FIT <br />E. WOOD BLOCKING AND CURBING <br />MATERIALS <br />LUMBER GRADING RULEa NFPA SPIR WCUB, <br />MISCELLANEOUS FRAMING STRESS GROUP D, <br />SPECIES, 19 PERCENT MAXIMUM MOISTURE CONTENT, <br />PRESSURE PRESERVATIVE TREAT <br />PLYWOOD' APA RATED SHEATHING, GRADE C-D, <br />EXPOSURE DURABILITY I SANDED, <br />ACC'ES <br />AW&%A <br />FASTENERS AND ANCI-IORR. <br />FASTENERS HOT -DIPPED GALVANIZED STEEL <br />FOR HGH HUMIDITY AND TREATED WOOD <br />LOCATIONS, UNFINSHED STEEL ELSEWHERE <br />ANCHORR TOGGLE BOLT TYPE FOR ANCHORAGE <br />TO HOLLOW MASONRY EXPANSION SHELD AND <br />LAG BOLT TYPE FOR ANCHORAGE TO SOLD <br />MASONRY OR CONCRETE BOLT OR BALLISTIC <br />FASTENER FOR ANCHORAGES TO STEEL <br />FACTORY WOOD TREATMENT <br />FIRE RETARDANT' AWPA TREATMENT C2A EXTERIOR <br />INTEF40R TYPF, CHEMICALLY TREATED AND PRESSURE <br />IMPREGNATED. <br />WOOD PRESERVATIVE (PRESSURE TREATME": <br />AWPA TREATMENT 01 USING WATER BORNE <br />PRESERVATIVE WITH 0.25 PERCENT RETAINAGE <br />WOOD PRESERVATIVE (SURFACE APPLICATICN� CLEAR <br />TYPE, COMPATIBLE WITH PRESSURE TREATED TYPE <br />SHEATHING <br />SECURE SHEATHING TO FRAMING MEMBERS WITH <br />ENDS OVER FIRM BEARING AND STAGGERED. <br />INSTALL TELEPHONE AND ELECTRICAL PANEL BOARDS <br />WITH PLYWOOD SHEATHING MATERIAL WHERE <br />REQUIRED. OVER SIZE THE PANEL BY 12 INCHES ON <br />ALL SIDES UNLESS SIZE IS CALLED FOR ON DOCUMENTS. <br />PANEL SHALL BE 3kV THICK UNLESS OTHERWISE NOTED <br />E. SHEET METAL FLASHING AND TRIM <br />PERFORMANCE REQUIREMENTS <br />INSTALL SHEET METAL FLASHING AND TRIM TO WITHSTAND <br />WIND LOADS, STRUCTURAL MOVEMENT, THERMALLY INDUCED <br />MOVEMENT, AND EXPOSURE TO WEATHER AND LIQUID WATER <br />WITHOUT FAILING AND WILL WITHSTAND WIND LOADS, THERMALLY <br />INDUCED MOVEMENT, AND EXPOSURE TO WEATHER <br />WITHOUT FAILURE. <br />FABRICATE AND INSTALL FLASHINGS AT ROOF EDGES <br />TO COMPLY WITH FM LOSS PREVENTION DATA SHEET 1-49 FOR <br />WIND ZONE 1 (20-30 PSF) <br />METALS <br />MILL -FINISH ALUMINUM SHEET ASTM B 2D9, 30034M, WITH <br />MINIMUM THICKNESS OF 0.040 INCH, UNLESS OTHERWISE NOTED <br />REGLETS <br />UNITS OF TYPE, MATERIAL AND PROFILE INDCATEDI, FORMED <br />TO PROVIDE SECURE INTERLOCKING OF SEPARATE REGLET <br />AND COUNTERFLASHING PIECES AND COMPATIBLE WITH FLASHING <br />INDICATED. REGLET ACCESSORIES INCLUDE SURFACE -MOUNTED, <br />STUCCO AND MASONRY TYPE PROVIDED BY EITHER <br />FRY REGI-ET, HICKMAN, OR KEYSTONE FLASHING COMPANY. <br />ACCESSORIES <br />FASTENERS ASPHALT MASTIC ELASTOMERIC SEALANT EPDXY <br />SEAM SEALER ADHESIVES, METAL ACCESSORIES, ROOFING CEMENT <br />FABRICATION <br />FABRICATE SHEET METAL FLASHING AND TRIM T COMPLY <br />WITH RECOMMENDATIONS OF SMACNAS 'ARCHITECTURAL SHEET <br />METAL MANUAL! THAT APPLY TO THE DESIGN, DIMENSIONS, <br />METAL, AND OTHER CHARACTERISTICS OF THE ITEM INDICATED <br />FORM EXPOSED SHEET METAL WORK WITHOUT EXCESSIVE OIL <br />CANNING AND BUC-4<1-IW;� AND FABRICATE NON-4VIOVING <br />FLAT --LOCK SEAMS SEALEDwnH EPDXY SEAM SEALER <br />SPACE MOVEMENT JOINTS AT 10 FEET MAXIMUM WITH NO JOINTS <br />ALLOWED WITHIN 24 INCHES OF CORNER OR INTERSECTION <br />LAPPED OR BAYONET -TYPE TO HAVE EXPANSION JOINTS OF <br />INTERMESHING HOOKED FLANGES NOT LESS THAN I INCH DEEP <br />FILLED WITH MASTIC <br />SEPARATE METAL FROM NOWOMPATIBLE ME7AL OR CORROSIVE <br />SUBSTRATES BY COATING CONCEALED SURFACES AT LOCATIONS <br />OF CONTACT WITH ASPHALT MASTIC OR OTHER PERIVIANENT <br />SEPARATOR <br />CCNCCEAL FASTENERS AND EXPANSION PROVISIONS WHERE <br />POSSIBLE EXPOSED FASTENERS ARE NOT ALLOWED ON FACES <br />OF SHEET METAL EXPOSED TO PUBLIC MEW <br />FABRICATE CLEATS AND ATTACHMENT DEVICES FROM SAME <br />METAL COMPONENT BEING ANCHORED <br />PRODUCT MATERIALS <br />RR P TRATION FLASHING LEAD AT 4.0 LB PER SF <br />H TV <br />PERED <br />SCUPPERS. ALUMINUM AT 0.032 INCH THICK <br />EXPOSED TRIMS, GRAVEL STOPS, AND FASCIA ALUMINUM <br />AT 0.05 INCH THICK <br />CXX1NIGS: ALUMINUM AT 0.05 INCH THICK <br />COUNTERFLASHM-L ALUMINUM AT 0.032 INCH THICK <br />DRIP EDGES, ALUMINUM AT 0.05 INCH THICK <br />FINISHES <br />COMPLY WITH ALUMINUM ASSOCATKNS IDESGNATION <br />SYSTEM MR ALUMINUM FINISHES' <br />HIGH --PERFORMANCE ORGANIC COATING FINISH: AA-CVC42RIX <br />PREPARF, PRETREAT, AND APPLY COATING TO EXPOSED <br />METAL SURFACES MANUFACTURERS STANDARD 2-COAT <br />FLUOROPOLYMER SYSTEM TO COMPLY WITH AAMA 6052 <br />COLOR AND GLOSS TO BE SELECTED BY ARCHITECT <br />G, SBS—MODIFIED BITUMINOUS SHEET ROOFING <br />PERFORMANCE REQUIREMENTS <br />INSTALL A WATERTIGHT, MODRED BITUMENCUS MEMBRANE <br />ROOFING AND BASE FLASHING SYSTEM WITH COMPA11BLE <br />COMPONENTS THAT WILL NOT PERMIT THE PASSAGE OF <br />LIQUID WATER AND WILL WITHSTAND WIND LOADS, THERMALLY <br />INDUCED MOVEMENT, AND EXPOSURE TO WEATHER <br />WITHOUT FAILURE, <br />SHEE7 ROOFING AND COMPONENT MATERIALS TO COMPLY <br />WITH UL FOR CLASS A EXTERNAL FIRE EXPOSURE FIM 1-90 <br />WIND UPLIFT CLASSIFICATION, ASTM E 84 AND 119 <br />WARRANTY <br />FURNISH WRITTEN WARRANTIES THAT SHALL COVER ANY AND <br />ALL NECESSARY LABOR AND MATERIAL FOR REPAIR OR <br />REPLACEMENT WORK REQUIRED TO KEEP AND MAINTAIN THE <br />ROOFING MEMBRANE AND MEMBRANE FLASHING WORK IN A <br />WATERTIGHT AND FIRST CLASS CONDITION AT NO ADDITIONAL <br />COST TO OWNER WARRANITES SHALL BE FURNIISHED AS <br />FOLLOWS AFTER THE DATE OF SUBSTANTIAL COMPLETION <br />TWO (2) YEARS BY THE ROOFING INSTALLER <br />TWENTY (20) YEARS BY MANUFACTURER OF ROOFING PRODUCT <br />ONE 0 YEAR BY GENERAL CONTRACTOR <br />SUBMITTALS <br />SHOP DRAWIW�S INCLUDING PLANS, SECTM, DETAILS FOR <br />BASE FLASHINGS� CANTS, MEMBRANE TERIMINATIONS, FASTENING <br />PATTERNS CRICKETS SADDLES AND TAPERED EDGE STRIPS <br />WRITTEN CERTIFICATION FROM ROOFING MANUFACTURER OF <br />MODIFIED BITUIVIENOUS SYSTEM CERTIFYING THAT INSTALLER IS <br />APPROVED BY MANUFACTURER TO INSTALL SPECIFIED SYSTEM <br />SUBMIT CALCULATIONS CERTIFYING THAT BASE LAYER AND <br />INSULATION SYSTEM WILL PROVIDE A MINIMUM AVERAGE AGED <br />R-VALUE OF R20 FOR THE COMPOSITE ROOF ASSEMBLY <br />AR"MA IINARMA'0-102301 <br />SUBMIT CE-RnFICATION BY ROOFNG MANUFACTURER THAT <br />CONTRACT DOCUMENTS ARE ACCEPTABLE TO THEM FOR <br />THE DECK AND SURFACM TO WHICH TI-iEY ARE APPLIED <br />F Cf-7ALS ARE NOT ACCEPTABLE BY MANLIFACTUFEI� SUBMIT <br />PROPOSED CORRECTIVE DETAILS AND REASONS FOR <br />NON -ACCEPTANCE NO DE�VIATION IS TO BE MADE FROM THIS <br />SPECIFICATION WITHOUT PRIOR APPROVAL BY THE ROOFING <br />MANUFACTURER AND SUBMITTED TO ARCHITECT <br />INSPECTION PRIOR TO, DURING, AND COMPLETION OF THE <br />ROOFING INSTALLATION SHALL BE MADE BY A REPRESENTATIVE <br />OF THE MANUFACTURER IN ORDER TO ASCERTAIN ROOFING <br />SYSTEM HAS BEEN INSTALLED PROPERLY ACCORDING TO <br />THEIR SPECIFICATIONS, STANDARDS, AND DETAILS <br />ROOFING SYSTEM AND MATERIALS <br />2-PLY SBS MODIFIED BITUMEN ELASTOMERIC, ROOFING <br />SYSTEM FOR G[-UE-DOWN INSTALLATION OVER RGD <br />INSULATION. <br />BASE PLY CONSISTS OF SMOOTH SBS RB69GLASS OR <br />POLYESTER RSNIFORCED, 118 MIL THICK MEMBRANF, 80 LBS <br />PER 100 SQUAFE FEET (AVERAGE) <br />CAP PLY CONSSTS OF SBS FIBERGLASS OR POLYESTER <br />REINFORCED, 120 MIL THICKNESS WITH WHITE GRANULAR <br />SURFACF, 90 LBS. PER 100 SQUARE FEET (MINIMUM) <br />FLASHINGS CONSIST OF SBS FIBERGLASS OR POLYESTER <br />REINFORCED, 98 ML THICKNESS MIR, FACED WITH EMBOSSED <br />ALUMINUM FOIL, 90 LBS PE14 100 SQUARE FEET (MIN!") <br />RCOFINGi BITUMENS CONSIST OF ROOFNG ASPHALT TO <br />COMPLY WITH ASTM D31Z TYPE N <br />MANUFACTURERS <br />SIPLAST PARADENE 20/30 FR WITH PARADENE 20 EG <br />BASEAND PARADIENE 30 FIR CAR WITH VERAL ALUMINUM <br />SURFACED FLASH1% SYSTEM APPLIED OVER PARADENE <br />20 EG FLASHING BASE PLY <br />SCPREMA 2144 FR WITH SOPRALENE 180 SANDED BASE AND <br />SOPPALENE 180 FR GRANULES CAP, WITH SOPRALAST 50 TV ALU <br />ALUMINUM SURFACED FLASHING SYSTEM APPLIED OVER <br />SOPRALENE FLAM 180 FLASHING BASE PLY <br />APPROVED EQUIVALENT <br />NOTE VOIDS AIR POCKETS, RIDGE$, AND WRINKLES SHALL <br />NOT BE ACCEPTABLE AS A FINISHED PRODUCT <br />RELATED MATERIALS <br />WOOD MEMBERS TO COMPLY WITH ROUGH CARPENTRY <br />CANTS PERUTE BOARD ASTM C 728 OR SOLD PT WOOD <br />TAPERED EDGE STRIPS: RIGID PERIJTE BOARD, ASTIM C <br />WALKWAY PROTECTION BOARDS. THICK BITUMINOUS PANELS <br />SUBSTRATE JOINT TAPE 6' OR 8" WIDE, COATM GLASS-FIBM <br />MASTIC SEALANT <br />ASPHALT PRIMER ASTM D41 <br />m- -68- <br />COMPLY WITH INS"TICNI MANLIFACTUTEM WFf rf EN <br />INMWTM FOR TFE STCPAGI� HANDUSIGA tWALLATK)K <br />AND ANCHORAGE OF N&LATION M SLeSTRATE OR DECK <br />H. JOINT SEALERS <br />PERFORMANCE REQUIREMENTS <br />PROVIDE ELASTOMERC JOINT SEALANTS THAT HAVE BEEN <br />PRODUCED AND INSTALLED TO ESTABLISH AND MANTAN <br />WATERTIGHT AND AfITGHT CONTINLCUS SEALS WITHOUT <br />CAUSING DETERICATION OF JOINT SUBSTRATES <br />ELASTOMERIC JOINT SEALANTS <br />COMPLY WITH ASTM C 920 AND CLASSIFICATIONS FOR TYPF, <br />GRADE, GLASS, AND USES <br />SlW;iLE PART POURA&E URETHANE SEALANIT FOR USE T <br />BY VULKEM 45/MAMECO INTERNATICINAL INC. OR <br />APPROVED EQUAL <br />ONE -PART NONSAG URETHANE SEALANT FOR USE NT <br />BY "VULKEM 921'lMAMEC0 INTERNATIONAL INC <br />LATEX JOINT SEALANTS <br />USE 'AC-20"/PECORA CORP. OR 'SONOLAC7SONNEBORN <br />BUILDIW;, PRODUCTS OR APPROVED EQUAL AS TO COMPLY <br />WITH ASTM C 834 <br />ACOUSTICAL JOINT SEALANTS <br />PROVIDE NONSAG, PAINTABLE, NON-STAJNIW3 LATEX <br />SEALANT COMPLYING WITH ASTIVI C 834 <br />FOR CONCEALED JOINTS USE NON-DRYING, NON -HARDENING <br />SYNTHETIC RUBBER SE&k4-f FOR INTERIOR JOINTS <br />JOINT SEALANT BACI'QNG <br />PLASTIC FOAM JOINT FILLERS PREFORMED COMPRESSIBLE, <br />RESILIENT, NON -STAINING MATERIAL THAT IS CLOSED-CFELL <br />POLYETHYLENE FOAM AND NON-ABSORBANT TO LIQUID WATER <br />OR GAS AND COMPUES WITH ASTM D 1623 AND ASTM C 1083 <br />JOINT FILLERS FOR CONCRETE PAVING <br />BITUMENOUS FIBER JOINT FLLER PREFORMED STRIPS <br />OF ASPHALT SATURATED FIBEREIOARD, USE EITHER <br />*RBER EXPANSION JOINT" - THE BURKE COMPANY OR <br />'TEX-LITE FIBER - J&P PETROLEUM PFIODUCTS INC <br />SPECIFICATIONS GENERAL NOTE: <br />THE SPECIFICATIONS INDICATED ON THIS PAGE ARE ARCHITECTS <br />RECOMMENDATIONS ONLY. NOT ALL ITEMS ARE APPLICABLE TO THIS PROJECT, <br />GENERAL CONTRACTOR TO VERIFY OWNER'S PREFERENCES PRIOR TO ORDERING <br />MATERIALS OR PERFORMING WORK <br />1. STANDARD STEEL FRAMES <br />PRODUCTS/MANUFACTURERS <br />AMWELD BUILDING PRODUCTS <br />CECO CORPORATION <br />MESKER INDUSTRIES <br />FIREDOOR OF FLORIDA <br />STEELCRAFT MANUFACTURING COMPANY <br />FRAMES <br />INTERIOR FRAMES 16 GAGE THICK MATERIAL, BASE <br />METAL THICMESS <br />ACCESSORIES <br />SILENCEF&' RESILIENT RUBBER FITTED INTO DRILLED HOLE <br />REMOVABLE STOPS: POLLED STEEL CHANNFI SHAPE, <br />MITERED CORNERS, PREPARED FOR COUNTERSINK STYLE <br />TAMPER PROOF SCREWS <br />BITUMINOUS COATING, FIBERED ASPHALT EMULSION <br />PRIMER ZINC CHROMATE TYPE <br />FINISH <br />STEEL SHEET GALVANIZED TO ASTM A525 G60 FOR <br />INITERIOR AND G90 FOR EXTERIOR <br />PRIMER BAKED <br />INSTALLATION <br />INSTALL FRAMES IN ACCORDANCE NTH ANSVSD-100 AND DHI <br />COORDINATE W/ WALL CONSTRUCTION FOR ANCHOR PLACEMENT <br />COORDINATE INSTALLATION OF FRAMES WITH INSTALLATION <br />OF HARDWARE AS SPECIFIED <br />J. FLUSH DOORS (IF APPLICABLE <br />WARRANTY <br />PROVIDE WARRANTY FOR LIFE OF INTERIOR DOORS <br />PRODUCTS/MANUFACTURERS <br />DOOR MERICA - AMERICAN SERIES <br />CRAFTMASTER <br />MASTER CRAFT <br />MASONITE FLUSH SERIES <br />OR EQUAL APPROVED BY ARCHITECT <br />DOOR CONSTRUCTION <br />FLUSH SOLID CORE WOOD NT0:4OR DOORS 1 3W THICK <br />PREFINISHED TO MATCH EXISTING NTEF40R DOORS <br />SUBMIT SAMPLE FOR OWNER / ARCHITECT REVIEW BEFORE ORDERI% <br />K. HARDWARE (IF APPLICABLE <br />PRCIDUCCTS/MANUFACTUIRERS <br />HINGES HAGER, STANLEY, AND MCKINNY <br />PUSH/PULLR ROCKWOOD, HAGER AND IVES <br />CYLINDER LOCKS: RUSSWIN, SCHLAGE AND SARGENT <br />SCHLAGE 'S' SERIES HAGER # M SERES W/ GRADE 2 CYLINDRICAL <br />LEVERS OR APPROVED EQUAL <br />CLOSERR LON RUSSWIR OR SARGENT <br />LCN 1461 SERIES, HAGER # 5200 SERIES OR APPRCVED EQUAL <br />CONCEALED CLOSERS USE LCN, DORMA� RIXSON <br />PANIC HARDWARE- VON DUPRIN OR APPROVED EQUAL <br />VON DUPRIN 22 SERIES WITH PP RIM DEVICE AND 210 NL TRIK HAGER <br />#4700 SERIES EXJT DEVICE OR APPROVED EQUAL <br />OVERHEAD HCLDER& GLYNN-JOHNSON, AND RXSON <br />NO RASTC END CAP ACCEPTED <br />MANUAL AND AUTOMATIC BOLTS� IVES, HAGER AND DO <br />GASKETING: PEIVIKQ DURAELF, AND NATIONAL GUARD <br />PROTECTION PLATER ROCKWOOD, HAGER, AND IVES <br />MOUNTING HEIGHTS <br />HINGE-S US26 LOCKSETS 38 INCH <br />LOCKS LJS26 PUSH/PULLS 42 INCH <br />CLOSERS US26 DEAD LOCKS 48 INCH <br />EXIT DEVICES US26 EXIT DEVICES 38 INCH <br />PUSH, PULL US26 <br />ALL MOUNTING HEIGHTS TO <br />KICK PLATES COMPLY WITH FBC 2001 AND <br />MISCELLANEOUS US26 HANDICAP ACCESSIBILITY <br />REQUIREMENTS <br />L. ALUMINUM ENTRANCES AND STOREFRONTS <br />SYSTEM PERFORNIANCE REQUIREMENTS <br />PROVIDE ALUMINUM ENTRAME AND STOREFRONT SYSTEM <br />CAPABLE OF WITHSTANDING LOADS, THERMAL, AND STRUCTURAL <br />MOVEMENT REQUIREMENTS WITHOUT FALLIFE, BASED ON <br />TESTING MANUFACTURERS STANDARD UNITS. FAILURE INCLUDES: <br />AIR INFILTRATION AND WATER PENETRATION EXCEEDING DESIGN <br />CRITERIA AND FRAMING MEMBERS TRANSFERflNIG STRESSES <br />CAUSED BY THERMAL AND STRUCTURAL MOVEMENT TO GLAZING <br />DESIGN CRITERIA <br />PHYSICALLY AND THERMALLY ISOLATE GLAZING FROM FRAMING <br />MEMBERS AND PROVIDE GLAZING TO GLAZJW;a JOINTS THAT <br />ACCOMMODATE THERM& AND MECHANICAL MOVEMENT AND <br />MAINTAIN EDGE CLEARANCES <br />STOREFRONT SYSTEMS AND ANCHORAGE TO BE CAPABLE OF <br />WITHSTANDING WIND LOAD DESIGN PRESSURES OF 26 LB PER SF <br />AS MEASURED IN ACCORDANCE WITH ASTIM E330 <br />STOREFRONT SYSTEMS TO PROVIDE PERMANENT RESISTANCE <br />TO AIR INFILTRATION OF NOT MORE THAN 006 CFM PER SF <br />OF FIXED WALL AREA MEN TESTED ACCORDING TO ASTIVI E 283 <br />AT STATIC-ARr-DIFFERENCE OF 1.57 LB PER SF <br />STOREFRONT SYSTEMS TO PROVIDE PEI:#VMENT RESISTANCE <br />AGAINST WATER PENETRATION AS TESTED ACCORDING TO <br />ASTM E 331 AT MN DIFFERENTIAL PRESSURE OF 20 PERCENT <br />OF INWARD ACTING WIND LOAD DESIGN PRESSURE, BUT NOT <br />LESS THAT 624 LB PER SF <br />IMPACT - RESISTANT CONDITIONS SHALL BE ACHEVED THROUGHOUT <br />AS REQUIRED BY CODE SEE STRUCTRAL ENGINEERIWG FOR WIND <br />LOAD PRESSURE REOUREMENTS <br />SUBMITTALS <br />PROVIDE SHOP DRAWINGS TO SHOW DETAILS OF FABRICATION <br />AND INSTALLATION, INCLUDING PLANS� ELEVATIONS, SECTIONS <br />AND DETAILS NTH PROVISIONS FOR THERMAL EXPANSION <br />PROVIDE STANDARD CCLOR CHART FOR SELECTION BY ARCHITECT <br />TEST REPORTS BY AN INDEPENDENT TESTING AGENCY TO SHOW <br />COMPLIANCE WITH THE ABOVE WRITTEN DESIGN CRITERIA <br />WARRANTY <br />SUBMIT WRITTEN WARRANTY EXECUTED BY THE MANUFACTURER <br />AGREEING TO REPAIR OR REPLACE COMPONENTS OF ENTRANCE <br />AND STOREFRONT SYSTEMS THAT FAIL IN MATERIALS OR <br />WOWMANSHIP WITHIN THE MANUFACTURERS STANDARD WAFRANTY <br />PERIOD <br />PRODLCTS/MANUFACTUIRERS <br />ARCH ALUMINUM AND CLASS 00, <br />\AESTSHORE GLASS CORP <br />EFCO IW. <br />YKK AMERICA, INC. <br />KAWNEER OR APPROVED EQUAL <br />RELATED MATERIALS <br />GO AND/OR STOREFRONT MANUFACTURER SHALL PROVIDE THE <br />FOLLOWING ITEMS AS PART OF THE COMPLETE STOREFRONT SYSTEM <br />ALUMINUM FRAMING AND FRAMING ACCESSORIES <br />STEEL RFJNFORCEMENT ASTMI A 611 AND 570 (AS RECD) <br />GLAZING AND GLAZING GASKETS <br />FRAMING SYSTEM GASKETS, SEALANTS, AND JOINT FILLERS <br />SEALANTS AND JOINT RLLEFtS FOR JOINTS AT PERIMETER <br />BITUMENOUS PANT <br />STOREFRONT COMPONENTS <br />CENTER GLAZE SCREW SPLINE STOREFRONT <br />FRAMING OR APPROVED EQUAL <br />4! STILE DOOR OR EQUAL MANUR DOOR TO BE <br />13/4' THICK GLAZED DOOR WITH MIN. 0,125 WA THICK EXTRUDED <br />TUB" RAIL AND STILE MEMBERS (6063-T5 OR T6 ALLOY) <br />BRACKETS AND RENFCRCEMENITS, COMPATIBLE WTH <br />ADJACENT MATERIALS <br />FASTENERS AND ACCESSORIES, C09POSCN-FESISTANT <br />CONCEALED RASHINGA C09ROSCN RESSTANT <br />WEATHER STRIPPINn MOLDED NEOPRENE COMPLYIW3 WITH <br />ASTM D 2000 <br />IMPACT - RESISTANT CONDITIONS SHALL BE ACHIEVED THROUGHOUT <br />AS REQUIRED BY CODE SEE STRUCTRAL ENGINEERING FOR WIND <br />LOAD PRESSURE REQUIREMENTS <br />HARDWARE <br />THRESHOLD EXTRUDED ALUMINUM ONE PIECE PER DOOR OPENINQ <br />NON-SLP SURFACE PER MANUFACTURERS STANDARD LINE <br />PULLS HANIDLE& STOREFRONT MANUFACTURERS STANDARD LINE <br />PUSH BARR STOREFRONT MANUFACTURERS STANDARD LINE <br />CLOSEFS: MANUFACTURER ST"ARD SIMILAR TO <br />RIX901\0 WITH M19 INTERMEDIATE PIVOT (US26) <br />TO COMPLY WITH CLOSING CYCLE FOR FBC 2002 AND ADA <br />CYLINDERR MANUFACTURER STANDARD DOUBLE CYLINDER WITH <br />DEADBOLT LOCK DEVICE <br />CYLINDER GUARDS: PER MANUFACTURER STANDARDS <br />WEATHER SWEEP MANUFACTUPOTS STANDARD EPDM BULB -TYPE <br />NOTE ALL HARDWARE SHALL HAVE STANDARD BRUSHED NICKEL <br />FINISH AND TO BE SELECTED BY ARCHITECT <br />FINISHES <br />FLUOROPOLYMER 2--COAT COATING SYSTEM PER MANUFACTURERS <br />THERMOCAJRED SYSTEM COMPOSED OF INHIBITIVE PRIMER AND <br />FLUCHOPMYMER COLOR TOPCOAT CONTAINING NOT LESS THAN <br />70 PERCENT POLYVINYUDENE FLUORIDE RESIN BY WEIGHT <br />COMPLY WITH AAMA 6052 <br />MANUFACTURERS STANDARD CCLOR LINE SELECTED BY ARCHITECT <br />GLAZING <br />STOREFRONT DOOR, TRANSOM, AND GLAZING BELOW 1T AFF <br />SHALL BE FULLY TEMPERE11% WITH HORIZONTAL TEMPEP44G <br />TO OONFORIVI WITH ANSI Z97.1 - IMPACT - RESISTANT GLAZING THROUGHOUT. <br />SEE GLAZING SPECIFICATION SECTION <br />INSTALLATION <br />WHERE ALUMINUM WILL CONTACT DISSIMILAR METALS, PROTECT <br />AGAINST GALVANIC ACTION BY PAINTING CONTACT SURFACES <br />WITH PRIMER OR BY APR-YING SEALANTITAPE AS <br />PECCMMENDED BY MANUFACTURER <br />WHERE ALUMINUM WILL CONTACT COqCRETE OR MASONRY, <br />PROTECT AGAINST CORROSION BY PANTING CONTACT SURFACES <br />WITH BITUMENOUS PANT <br />INSTALL COMPONENTS TO DRAIN WATER PASSI% JOINTS <br />AND CONDENSATION OCCURING OR MIGRATING WTrHIN THE <br />SYSTEM TO THE EXTERIOR <br />M. GLAZING <br />SYSTEM PERFORMANCE REQUIREMENTS <br />PROVIDE GLAZING SYSTEMS THAT ARE PRODUCED, FABRCATED� <br />AND INSTALLED TO WITHSTAND NORMAL THERMAL MOVEMENT, <br />WIND LOADING, AND IMPACT LOADING, WITHOUT FAILURE <br />INCLUD114G LOSS AND GLASS BREAKAGE ATTP43UTABLE TO <br />THE FOLLOVONG <br />DEFECT7VE MANUFACTURE, FABRICATION, AND NSTALLATION <br />FAILURE OF SEALANTS OR GASKETS TO REMAIN WATERTIGHT <br />AND AJRTIC44T <br />DETERIORATION OF GLAZING MATERALS AND OTHER DEFECTS <br />IN CONSTRUCTION <br />GLASS THICKNESS INDICATED ON DRAWINGS ARE FOR <br />DETAILING ONLY, CONFIRM GLASS THICKNESS BY ANALYZING <br />PROJECT LOADS MINIMUM GLASS THICKNESS = 1/4 INCH <br />OBTAIN GLASS FROM ONE SOURCE FOR EACH PRODUCT BELOW <br />PRIMARY GLASS OF EACH (ASTIVI C 1036) TYPE <br />HEAT -TREATED GLASS OF EACH (ASTM C 1048) CONDITION <br />POLISHED WIRED GLASS (ASTIVIC 1048) <br />PRODUCTS/MANUFACTURERS <br />PRIMARY FLOAT GLASS: ASTM G 1036, TYPE I, <br />TRANSPARENT GLASG� FLAT, QUALITY 03 <br />CLASS 1 (CLEAF4 UNLESS OTHERWISE INDICATED <br />CLASS 2 (SMOKE TINTED, HEAT-ABSORBW-i AND LIGHT <br />PEDUCIW:3) MERE INDICATED. <br />FULL HEIGHT V4� MIRROR UNLESS OTHERWISE NOTED <br />HEAT -TREATED FLOAT GLASS ASTM C 1048, CONDITION A <br />TYPE 1, CLASS 1 OR 2 (AS INDICATED), FLAT, QUALITY 03 <br />FT CLASS 1 (CLEARI UNLESS OTHERWISE INDCATED <br />FT CLASS 2 (SMOKE- TINTED, HEAT-ABSORBINCA AND LIGHT <br />REDUCING) WHERE INDICATED. <br />FULL HEIGHT 1/4� FULLY TEMPERED AS SPECIFIED <br />ALL EXTERIOR GLAZI% SHALL BE IMPACT--FESISTANT, DOUBLE <br />INSULATED� LIGHT GRAY TINT PER DRAWINGS <br />N. PORTLAND CEMENT PLASTER <br />PRODUCTS/MANUFACTURER <br />EXPANDED METAL LATH <br />DETFICH INDUSTRIES INC. <br />UNITED STATES GYPSUM CO. <br />DALE / INCOR INDUSTRIES INC <br />UNIMAST INC <br />METAL ACCESSORIES <br />FRY REGLET CORPORATION <br />UNITED STATES GYPSUM CO. <br />DALE / INCOR INDUSTRIES NC <br />UNIMAST INC <br />PLASTIC ACCESSORIES <br />ALABAMA METAL INDUSTRIES CORP. <br />PLASTIC COMPONENTS INC <br />VINYL CORP, <br />STUCCO ACCESSORIES <br />FLORIDA STUCCO CORP, <br />HIGHLAND STUCCO <br />UNITED STATES GYPSUM 00. <br />RELATED MATERIALS <br />EXPANDED METAL LATH TO COMPLY WITH ASTM C 847 <br />STRUCTURAL QUALITY ZINC COATED CCMPL'rl% WITH <br />ASTIVI A 653, G60 DIAMOND MESH TYPE <br />PAPER BACKED LATH TO COMPLY WITH FS UU-13-790 <br />TYPE I; VAPOR -PERMEABLE PAPER GRADE D, STYLE 2 <br />CORNERBEADS, CASING BEADS, AND CONTROL JOINTS <br />SHALL BE PVC PLASTIC TYPE, MR 0.035 INCH THICK <br />PORTLAND CEMENT BASE COAT, ASTM C 150� TYPE I <br />PORTLAND CEMENT FINISH COAT PER MANUFACTUIFERS <br />STANDARD PACKAGED STUCCO, INCLUDING PORTLAND <br />CEMENT, AGGREGATE, AND OTHER PROPRIETARY 84GREDENTS <br />SAND AGGREGATE FOR BASE COATS* ASTIVI C 897 <br />INSTALLATION <br />TWO COAT WORK OVER CONCRETE UNIT MASONRY <br />BASE -COAT' 1 PART PORTLAND CEMENT, 3/4 TO 11/2 PARTS <br />LIMF, 3-4 PARTS AGGREGATE, 3/8' THICKNESS <br />THREE COAT WORK OVER METAL LATR <br />SCRATCH COAT 1 PART PORTLAND CEMENT, 0 TO 3/4 PARTS <br />LIMF- 2 1/2 TO 4 PARTS AGGREGATE, 3/8" THICKNESS <br />BROWN COAT I PART PORTLAND CEMENT, 0 TO 314 PARTS <br />LIMF- 3-5 PARTS AGGREGATF, 1/4� THICKNESS <br />FINISH COAT. PROPORTION MATERIALS FOR FINISH COATS <br />IN PARTS BY VOLUME. USE 1 PART PORTLAND CEMENT, <br />34 TO 11/2 PARTS LIME 3 PARTS SAND, 1/8 INCH THICK <br />Issue Date <br />09-03-21 <br />00 <br />LL <br />ZZ LL <br />:) E <br />bgs <br />00 0 <br />-j 00 <br />M <br />co <br />A �� <br />3m <br />0 <br />6 <br />c: <br />U) <br />0 <br />C <br />0 <br />0 <br />LL <br />m <br />cli <br />> <br />0 <br />-c <br />L- <br />cu <br />>% <br />0 <br />CL <br />-c <br />N <br />4-a <br />cu <br />(D <br />0 -r <br />tf <br />4- <br />2:% <br />0 <br />() <br />c: <br />cl) <br />(D <br />< <br />E <br />m <br />0 <br />a) <br />-b-0 <br />C <br />0 <br />E <br />Job Nwrber <br />2008 <br />Revisilons <br />A <br />Sheet No. <br />A6 <br />