Laserfiche WebLink
1 "= 10, <br />15 10 5 0 10 20 30 <br />30 20 10 0 20 40 60 45 30 15 0 30 60 90 <br />1 "=20' 1 "=30' <br />60 4L. 20 0 40 80 120 <br />1 "=40' " 1 "=50' <br />7 50 25 0 5 100 150 <br />15 100 50 100 200 300 <br />1 "=100' <br />ABBREVIATIONS <br />A/C <br />AIR CONDITIONING <br />ELEV. <br />ELEVATOR <br />HW <br />HOT WATER <br />O.C. <br />ON CENTER <br />SQ. FT. <br />SQUARE FEET <br />A. B. <br />ANCHOR BOLT <br />EQ. <br />EQUAL <br />I.D. <br />INSIDE DIAMETER <br />O.D. <br />OUTSIDE DIAMETER <br />SQ. IN. <br />SQUARE INCHES <br />A.F.F. <br />ABOVE FINISHED FLOOR <br />EQUIP. <br />EQUIPMENT <br />I.F. <br />INSIDE FACE <br />O.H. <br />OVER HANG <br />STD. <br />STANDARD <br />AL. <br />ALUMINUM <br />EST. <br />ESTIMATE <br />ID <br />IDENTIFICATION <br />OH <br />OVER HEAD <br />STL. <br />STEEL <br />APPROX <br />APPROXIMATELY <br />EXC <br />EXCAVATE <br />INCL. <br />"INCLUDE, INCLUSIVE" <br />OPNG. <br />OPENING <br />SUSP, <br />SUSPENDED <br />ARCH <br />ARCHITECT <br />EXH. <br />EXHAUST <br />INSUL. <br />INSULATION <br />OPPO. <br />OPPOSITE <br />SW <br />SWITCH <br />BD. <br />BOARD <br />EXIST. or E <br />EXISTING <br />INT. <br />INTERIOR <br />P.C. <br />PRECAST CONCRETE <br />SYM <br />SYMMETRICAL <br />BLDG <br />BUILDING <br />EXT. <br />EXTERIOR <br />INFO. <br />INFORMATION <br />P.L. or P <br />PROPERTY LINE <br />SYS. <br />SYSTEM <br />BLK. <br />BLOCK <br />F.A. <br />FIRE ALARM <br />JST. <br />JOIST <br />PL. <br />PLASTER <br />T & G <br />TONGUE AND GROOVE <br />B. 0. <br />BOTTOM OF <br />F.C.O. <br />FLOOR CLEAN OUT <br />JT. <br />JOINT <br />PL. or R <br />PLATE <br />T.O. <br />TOP OF <br />BM. <br />BEAM <br />F.D. <br />FLOOR DRAIN <br />KIT <br />KITCHEN <br />PLYWD. <br />PLYWOOD <br />T.O.B. <br />TOP OF BEAM <br />BRG. <br />BEARING <br />F.E. <br />FIRE EXTINGUISHER <br />L.E.D. <br />LIGHT EMITTING DIODE <br />PREFAB. <br />PREFABRICATED <br />T.O.C. <br />TOP OF CURB <br />C.D. <br />CONSTRUCTION DOCUMENTS <br />F.S. <br />FLOOR SINK <br />L.FT. <br />LINEAR FEET <br />PSF <br />POUNDS PER SQUARE FOOT <br />T.O.F. <br />TOP OF FOOTING <br />C.I.P. <br />CAST IN PLACE <br />F.G. <br />FIBERGLASS <br />LAM <br />LAMINATE <br />PSI <br />POUNDS PER SQUARE INCH <br />T.O.J. <br />TOP OF JOIST <br />C.J. <br />CONTROL JOINT <br />FAB. <br />FABRICATE <br />LAT. <br />LATERAL <br />PTN. <br />PARTITION <br />T.O.M. <br />TOP OF MASONRY <br />C.O. <br />CLEAN OUT <br />FACP <br />FIRE ALARM CONTROL PANEL <br />LAV <br />LAVATORY <br />PVC <br />POLYVINYLCLORIDE <br />T.O.S. <br />TOP OF SLAB <br />CEM. <br />CEMENT <br />FDC <br />FIRE DEPARTMENT CONNECTION <br />— <br />LIN. <br />LINEAR <br />PWR. <br />POWER <br />T.O.W. <br />TOP OF WALL <br />C.T. <br />CERAMIC TILE <br />FDN. <br />FOUNDATION <br />LINO. <br />LINOLEUM <br />QTY. <br />QUANTITY <br />T.S. <br />TUBE STEEL <br />CAB <br />CABINET <br />FHC <br />FIRE HOSE CABINET <br />LT. <br />LIGHT <br />R.D.L. <br />ROOF DRAIN LEADER <br />TH. <br />THRESHOLD <br />CL or <br />CENTERLINE <br />FIN. <br />FINISH <br />LVL <br />LAMINATED VENEER LUMBER <br />R.D.O. <br />ROOF DRAIN OVERFLOW <br />THD. <br />THREADED <br />CLG. <br />CEILING <br />FL <br />FLOOR <br />M.H. <br />MANHOLE <br />R.O. <br />ROUGH OPENING <br />THK. <br />THICK <br />CLO. <br />CLOSET <br />FLG. <br />FLOORING <br />M.O. <br />MASONRY OPENING <br />R.O.W. or R ZW <br />RIGHT OF WAY <br />THRU <br />THROUGH <br />CLR. <br />CLEAR <br />FP <br />FIRE PROOF <br />MAR. <br />MARBLE <br />REF <br />REFRIGERATOR <br />TLT. <br />TOILET <br />CMU <br />CONCRETE MASONRY UNIT <br />FTC. <br />FOOTING <br />MAS. <br />MASONRY <br />REF. <br />REFERENCE <br />TRANS. <br />TRANSFORMER <br />CNTRD. <br />CENTERED <br />FURN. <br />FURNISH <br />MAT'L <br />MATERIAL <br />REINF. <br />REINFORCED <br />TYP. <br />TYPICAL <br />COL. <br />COLUMN <br />GA. <br />GAUGE <br />MAX. <br />MAXIMUM <br />REQ'D, <br />REQUIRED <br />UNF. <br />UNFINISHED <br />CONC, <br />CONCRETE <br />GALV. <br />GALVANIZED <br />MECH. <br />MECHANICAL <br />RET. <br />RETURN <br />UL <br />UNDERWRITERS LAB. <br />CONT. <br />CONTINUOUS <br />GAR. <br />GARAGE <br />MED. <br />MEDIUM <br />REV. <br />REVISION <br />UR <br />URINAL <br />D.F. <br />DRINKING FOUNTAIN <br />GL <br />GLASS <br />MFG. <br />MANUFACTURING <br />RM <br />ROOM <br />V.B. <br />VAPOR BARRIER <br />D.S. <br />DOWN SPOUT <br />GYP. <br />GYPSUM <br />MFR. <br />MANUFACTURER <br />R.O. <br />ROUGH OPENING <br />V.I.F. <br />VERIFY IN FIELD <br />D/W <br />DISHWASHER <br />H.B. <br />HOSE BIBB <br />MIN. <br />MINIMUM <br />S.C. <br />SOLID CORE <br />VERT. <br />VERTICAL <br />DEMO <br />DEMOLITION <br />H.C. <br />HOLLOW CORE <br />MISC. <br />MISCELLANEOUS <br />S/L <br />SKYLIGHT <br />W/C <br />WATER CLOSET <br />DIA. or 0 <br />DIAMETER <br />H/C <br />HANDICAPPED <br />MOD <br />MODULAR <br />S/S <br />STAINLESS STEEL <br />WDW <br />WINDOW <br />DIM. <br />DIMENSION <br />HGT. <br />HEIGHT <br />MTL. <br />METAL <br />SCHED. <br />SCHEDULE <br />WP <br />WEATHER PROOF <br />DL <br />DEAD LOAD <br />HOR. <br />HORIZONTAL <br />MUL <br />MULLION <br />SECT. <br />SECTION <br />WT. <br />WEIGHT <br />DN. <br />DOWN <br />HTR <br />HEATER <br />N.I.C. <br />NOT IN CONTRACT <br />SH <br />SHEET <br />W/ <br />WITH <br />DR <br />DOOR <br />HVAC <br />'HEATING VENTILATING do AIR CONDITIONING' <br />N.T.S. <br />NOT TO SCALE <br />SHT'G. <br />SHEATHING <br />W/0 <br />WITHOUT <br />DWG <br />DRAWING <br />E.W. <br />EACH WAY <br />NFC <br />NOT FOR CONSTRUCTION <br />SIM. <br />SIMILAR <br />WD. <br />WOOD <br />E.J. <br />EXPANSION JOINT <br />EA. <br />_ <br />EACH _ <br />NO. <br />NUMBER <br />SPA. <br />SPACE <br />WWF <br />WELDED WIRE FABRIC <br />E.N. <br />END NAILING <br />EL <br />ELEVATION <br />NOM, <br />NOMINAL <br />SPECS <br />SPECIFICATIONS <br />YD. <br />YARD <br />ELECT. <br />"ELECTRIC, ELECTRICAL" <br />m <br />m <br />Q <br />Madrid Ave <br />Barcelona Ave <br />Valencia Ave <br />Rd <br />Star <br />Pawn <br />aventHealth Zepr, <br />5 Arbor Frdg Dr, <br />Zip rh 11, FL 3,3540 <br />f.)aughtery1f d <br />New Troll Dr <br />Zeplhrhil s Cinema 0 <br />;fl <br />S 1 TE <br />SCALE: N.T.S. <br />PLAN <br />G1-0 <br />rN <br />Dallught+ery Rd <br />DATE <br />CrHy0-111ILLIS, <br />!:[� l�tAL <br />ALL WORK SHALL COMPLY WITH PREVAILING <br />CODES FLORIDA BUILDING CODE, <br />NATIONAL ELECTRIC CODE, <br />AND THE CITY OF ZEPHYRHILLS <br />-)RDINANCES <br />PROJECT LOCATION <br />NORTH <br />C� <br />Medical Viey,,I <br />GENERAL NOTES <br />1. GENERAL CONDITIONS: <br />THE GC SHALL VISIT THE PROJECT SITE AND EXISTING CONDITIONS PRIOR TO THE BEGINNING OF <br />THE WORK. <br />THE GC SHALL PROVIDE ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, UTILITIES, INSURANCE, <br />TRANSPORTATION, AND PAY FOR ALL REQUIRED TAXES, PERMITS, AND SERVICES REQUIRED TO <br />COMPLETE THE ENTIRE SCOPE OF WORK, WHETHER TEMPORARY OR PERMANENT. <br />ALL MATERIALS EXCEPT TEMPORARY FORMS ARE TO BE NEW, UNUSED AND OF THE SPECIFIED <br />QUALITY. <br />THE GC SHALL MAINTAIN THE PROJECT SITE IN A CLEAN AND ORDERLY FASHION. TOOLS AND <br />EQUIPMENT SHALL BE SECURED, AND ALL DEBRIS SHALL BE REMOVED DAILY. <br />THE GC SHALL MAINTAIN A VISITORS LOG. ALL VISITORS SHALL BE REQUIRED TO SIGN SUCH LOG. <br />DATES AND TIMES OF ENTERING AND EXITING THE SITE FOR ALL VISITORS SHALL BE NOTED. GC <br />TO SECURE PROJECT SITE FROM UNAUTHORIZED ENTRY AT ALL TIMES. <br />COORDINATE LOCATION OF BARRICADES OR TEMPORARY FENCING WITH THE DOCUMENTS AND <br />OWNER. <br />PHOTOGRAPHS SHALL BE TAKEN OF THE PROGRESS OF THE WORK AT INTERVALS NO GREATER <br />THAN 7 CALENDAR DAYS. PHOTOGRAPHS SHALL BE IN COLOR AND IDENTIFIED BY DATE AND TIME <br />OF DAY. MAINTAIN DIGITAL PHOTOGRAPH FILE ON DELIVER COMPLETED FILE TO THE ARCHITECT <br />UPON RECEIPT OF USE AND OCCUPANCY PERMIT. THE GC SHALL MAINTAIN AN ON SITE STAGING <br />AREA AND SHALL KEEP THE AGENCY APPROVED CONSTRUCTION DOCUMENTS, ALL LICENSING <br />INFORMATION, VISITORS LOG, PHOTOGRAPH FILE, AND AT LEAST ONE SET OF REPRODUCIBLE <br />CONSTRUCTION DOCUMENTS, TO BE MARKED CONCURRENTLY WITH THE CONSTRUCTION, TO <br />RECORD ACTUAL CONDITIONS OF THE CONSTRUCTION AND DEVICE INSTALLATIONS. DELIVER <br />COMPLETED REPRODUCIBLE RECORD SET TO THE ARCHITECT UPON COMPLETION OF THE <br />PROJECT. <br />GC TO REMOVE AND DISPOSE OF ALL WASTE AND DEBRIS FROM PROJECT SITE IN A LEGAL <br />MANNER. UPON COMPLETION OF THE WORK, PROVIDE PROFESSIONAL CLEANING SERVICE TO <br />CLEAN THE PROJECT SITE, INTERIOR AND EXTERIOR, FOR FINAL OCCUPANCY. <br />2. INTERPRETATION: <br />THE ARCHITECT/ENGINEER IS SOLELY RESPONSIBLE FOR THE DESIGN INTERPRETATION OF THE <br />CONSTRUCTION DOCUMENTS. <br />3. DOCUMENT DISCREPANCIES: <br />4. WHENEVER THERE ARE DISCREPANCIES IN THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL <br />BASE HIS BID UPON THE BETTER QUALITY OR GREATER QUANTITY OF THE MATERIAL OR WORK <br />DESCRIBED. <br />4. DRAWING SCALE: <br />THE CONTRACTOR SHALL NOT SCALE DRAWINGS. <br />5. FIELD CONDITIONS: <br />THE CONTRACTOR SHALL TAKE FIELD MEASUREMENTS AND VERIFY FIELD CONDITIONS AND SHALL <br />CAREFULLY COMPARE SUCH FIELD MEASUREMENTS, CONDITIONS, AND OTHER INFORMATION <br />KNOWN TO THE CONTRACTOR WITH THE CONTRACT DOCUMENTS BEFORE COMMENCING <br />ACTIVITIES. ERRORS, INCONSISTENCIES, OR OMISSIONS DISCOVERED SHALL BE REPORTED TO THE <br />ARCHITECT/ENGINEER AT ONCE. NO ALLOWANCE WILL BE MADE ON BEHALF OF THE CONTRACTOR <br />OR SUBCONTRACTORS FOR FAILURE TO VISIT THE SITE. <br />6. CONSTRUCTION MEANS... PROCEDURES. <br />THE GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING TH CONTRACTOR'S <br />BEST SKILL AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR AND HAVE <br />CONTROL OVER CONSTRUCTION MEANS. METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES <br />AND FOR COORDINATING ALL PORTIONS OF WORK UNDER THE CONTRACT, UNLESS CONTRACT <br />DOCUMENTS GIVE OTHER SPECIFIC INSTRUCTIONS CONCERNING THESE MATTERS. ANY WORK <br />THAT MUST BE REMOVED OR RELOCATED DUE TO LACK OF COORDINATION OF THE TRADES IS <br />SOLELY THE CONTRACTOR'S RESPONSIBILITY. THE CONTRACTOR SHALL MAINTAIN A SECURE SITE <br />THROUGHOUT THE CONSTRUCTION PROCESS. <br />7. PERMITS/INSPECTIONS: <br />UNLESS OTHERWISE PROVIDED IN THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL SECURE <br />AND PAY FOR THE BUILDING PERMIT AND OTHER PERMITS AND GOVERNMENTAL FEES, LICENSES <br />AND INSPECTIONS NECESSARY FOR PROPER EXECUTION AND COMPLETION OF THE CONTRACTOR <br />SHALL COMPLY WITH AND GIVE NOTICES REQUIRED BY LAWS, ORDINANCES, RULES, REGULATIONS, <br />AND LAWFUL ORDERS OF PUBLIC AUTHORITIES BEARING ON PERFORMANCE OF THE WORK. UPON <br />COMPLETION OF THE WORK, THE CONTRACTOR SHALL OBTAIN A USE AND OCCUPANCY PERMIT AS <br />REQUIRED FROM GOVERNING CODES. SUBMIT ONE COPY OF THE PERMIT TO THE OWNER WITH <br />FINAL APPLICATION OF PAYMENT. <br />INT€kOR FINISHES CHAPTER 8 - BUSINESS GROUP B <br />GROUP B - TABLE 803.11 <br />EXIT ENCLOSURES AND EXITS PASSAGEWAYS <br />B <br />CORRIDORS <br />B <br />ROOMS AND ENCLOSED SPACES <br />C <br />PARKING SPACES <br />HANDICAP 2 <br />STANDARD 16 <br />PROJECT DATA <br />SITE DATA <br />PROJECT ADDRESS: 38058 ARBOR RIDGE DRIVE <br />ZEPHYRHILLS, FL 33540 <br />PARCEL ID 35-25-21-0060-00000-0100 <br />JURISDICTION: CITY OF ZEPHYRHILLS - FLORIDA <br />TENANT AREA <br />TOTAL ASSEMBLY AREAS: <br />1432 SF <br />TOTAL WAITING AREAS: <br />376 SF <br />TOTAL ACCESSORY STORAGE AREAS: <br />146 SF <br />TRANSITIONAL AREAS. BATHROOMS, WALK-INS, CORRIDORS, PARTITIONS, ETC. <br />1165 SF <br />TOTAL TENANT SPACE - GROSS AREA <br />3120 SF <br />BUILDING CODE <br />SCOPE OF WORK: REMODELING / MODIFICATION OF EXISTING MEDICAL BUILDING <br />DESIGN CRITERIA: <br />FLORIDA BUILDING CODE 2020 (7TH EDITION) <br />FLORIDA BUILDING CODE 2020 (7TH EDITION) EXISTING BUILDING <br />FLORIDA BUILDING CODE 2020 (7TH EDITION) ACCESSIBILITY <br />FLORIDA BUILDING CODE 2020 (7TH EDITION) PLUMBING <br />FLORIDA FIRE PREVENTION CODE 2020 (7TH EDITION) <br />NFPA 72, NFPA 101, NFPA 13, NFPA 99, NEC 2017 <br />CONSTRUCTION TYPE: TYPE II-B <br />LEVEL OF DISCHARGE. 1 (TABLE 466.5) UNPROTECTED - NON - SPRINKLERED <br />ALTERATION LEVEL 2 <br />PRIMARY OCCUPANCY <br />GROUP "B" - BUSINESS <br />PRIMARY USE <br />HEALTH CARE FACILITY PROFESSIONAL SERVICES <br />BUILDING CODE ANALYSIS <br />TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCE PER OCCUPANT <br />AREAS PER USE <br />NUMBER OF OCCUPANTS <br />BUSINESS AREA 150 GROSS <br />1432 SF /150 <br />9.55 (10) OCCUPANTS <br />ACCESSORY STORAGE AREAS - 300 SF <br />146 SF/300 <br />0.49 (1) OCCUPANT <br />WAITING AREAS - 15 SF GROSS <br />376 SF/15 <br />25.1 (26) OCCUPANTS <br />RESTROOMS - 50 SF GROSS <br />119 SF/50 <br />2.38 (3) OCCUPANTS <br />TOTAL OCCUPANT LOAD <br />40 OCCUPANTS <br />MEAN OF EGRESS <br />40 x 0.15 = 6.0" (REQUIRED) 4x36" = 144" (PROVIDED) <br />NUMBER OF EXITS - 3 <br />PLUMBING FIXTURES CALCULATIONS <br />SINGLE TENANT OCCUPANT LOAD: GROSS OCCUPANT LOAD 40 OCUP. <br />TOTAL OCCUPANT LOAD = 40 OCCUPANTS 50% WOMEN = 20 OCCUPANTS <br />50% MEN = 20 OCCUPANTS <br />FBC 2020, SECTION 403, TABLE 403.1 <br />MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES PLUMBING FACILITIES <br />PRIMARY CLASSIFICATION -BUSINESS (B) (PROFESSIONAL SERVICES) <br />BUSINESS <br />OCCUPANCY <br />WATER CLOSETS <br />LAVATORIES <br />BATHTUB/ <br />SHOWER <br />DRINKING <br />FOUNTAIN <br />SERVICE <br />SINK <br />TYPE : B-3 <br />REQUIRED <br />1 <br />1 <br />N/A <br />1 <br />PROVIDED <br />2 <br />2 <br />N/A <br />- <br />7 <br />PERSONNEL <br />REQUIRED <br />1 <br />1 <br />N/A <br />PROVIDED <br />1 <br />1 <br />N/A <br />LIST OF DRAWINGS <br />SHEET <br />EET <br />No. <br />DESCRIPTION <br />PERMIT <br />REV.1 <br />REV.2 <br />ET <br />SHEET <br />DESCRIPTION <br />PERMIT <br />REV-1 <br />REV.2 <br />TITLE <br />ARCHITECTURAL <br />ELECTRICAL <br />G1-0 <br />GENERAL INFORMATION <br />CODE ANALYSIS <br />• <br />A1-0 <br />EXISTING PLAN <br />• <br />E1-0 <br />ELECTRICAL GENERAL NOTES <br />• <br />G1-1 <br />ADA STANDARDS <br />• <br />Al-01 <br />DEMOLITION PLAN <br />• <br />E1-1 <br />POWER PLAN <br />• <br />LS1-1 <br />LIFE SAFETY <br />• <br />Al-1 <br />PROPOSED PLAN <br />• <br />E1-2 <br />ELEC. REFLECTED CEILING <br />• <br />PLUMBING <br />A2-1 <br />WALL DETAIL & DOOR SCHED. <br />• <br />E1-3 <br />SCHEDULES <br />• <br />P1-1 <br />DRAINAGE PLAN & RISERS <br />• <br />E1-4 <br />P1-2 <br />HOT & COLD WATER PLAN <br />• <br />MECHANICAL <br />P1-3 <br />RISERS & SCHEDULE <br />• <br />STRUCTURAL <br />M1-1 <br />MODIFIED MECHANICAL PLAN <br />• <br />P1-4 <br />NO STRUCTURAL CHANGES <br />M1-2 <br />PROJECT NAME <br />MEDICAL BUILDING <br />MODIFICATIONS <br />s <br />OWNER <br />ADAA REAL ESTATE LLC <br />2653 BRUCE B DOWNS BLVD. <br />WESLEY CHAPEL, FL 33544 <br />PROJECT ADDRESS <br />38058 ARBOR RIDGE DRIVE. <br />ZEPHYRHILLS, FL 33540 <br />DRAWING BY <br />DANIEL JALIL <br />Associate AIA <br />M.A. In Architecture & Planning <br />10233 CELTIC ASH DR. <br />Ruskin, FL 33753 <br />Phone (813) 240-3537 <br />THIS DRAWING MEASURING 24"x36" IS THE PROPERTY OF DANIEL <br />JALIL AND MAY NOT BE USED OR REPRODUCED WITHOUT HIS <br />WRITTEN PERMISSION.. <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE <br />DATE IS SIGNED AND SEAI ED. <br />ENGINEER <br />I HEREBY CERTIFY THAT I HAVE <br />REVIEWED THE ATTACHED DESIGN AND <br />FOUND IT TO BE IN COMPLIANCE WITH <br />THE 7TH EDITION OF THE FLORIDA <br />BUILDING CODE 2020. <br />\xx11111111III//," <br />.�`�� JA MES �'' <br />��. 0 <br />* No.77065 <br />0'��; <br />SION <br />AL <br />DANIEL JAMES COOREY P.E. <br />FL77065 <br />Phone (813) 507-9166 <br />DATE ISSUED FOR: <br />SHEET TITLE <br />GENERAL INFORMATION <br />CODE ANALYSIS <br />JOB No. ZPH-0821 <br />SCALE AS NOTED <br />DATE AUG-09-21 <br />DRAW BY DJ <br />CHECKED BY DJ <br />PLOT DATE 08-09-21 <br />DRAWING No <br />3" <br />0 0 1 <br />1 1 /2"= V-0"1 0 1 2 <br />3/4"= V-0" <br />2 0 2 4 <br />1 /4"=1 '-0' <br />1 /8"=V-0"MNIO <br />8 4 0 5 10 6 0 10 20 <br />G1-0 <br />12 0 0 mmmm, 60 <br />