TRUSS AND FRAMING NOTES: <br />1. TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE APPLICABLE <br />PROVISIONS OF THE #NATIONAL DESIGN SPECIFICATION FOR WOOD <br />CONSTRUCTION" OF NFPA AND WITH THE TPI "DESIGN SPECIFICATION <br />FOR METAL PLATE CONNECTED WOOD TRUSSES". CHORD MEMBERS <br />SHALL BE K.D. SOUTHERN PINE, SURFACED DRY, NO.2 MINIMUM. <br />LIVE LOAD DEFLECTION SHALL BE LIMITED TO L/360. CONNECTOR <br />PLATES SHALL BE MADE OF ASTM A446, GRADE A, HOT -DIPPED <br />GALVANIZED (G60) STEEL AND APPLIED TO BOTH FACES OF TRUSS <br />AT EACH JOINT. TRUSSES WITH THREE SUPPORTS SHALL PROVIDE <br />FOR HORIZONTAL MOVEMENT AT ONE. <br />2. ROOF TRUSS SUPPLIER SHALL BE RESPONSIBLE FOR THE DESIGN OF <br />THE ROOF TRUSS SYSTEM. DESIGN OF THE SYSTEM SHALL BE PREPARED <br />SIGNED AND SEALED BY A QUALIFIED FLORIDA REGISTERED PROFESSIONAL ENGINEER. <br />COPIES OF COMPLETE SHOP DRAWINGS, INCLUDING TRUSS LAYOUT AND <br />BRACING, SHALL BE SUBMITTED FOR THE CONTRACTOR'S REVIEW. <br />DURATION FACTORS USED FOR DESIGN SHALL BE 1.25 FOR D+L AND <br />1.33 FOR D+W LOADS. SUBMITTALS SHALL INDICATE UPLIFT LOADS PER <br />PROJECT WIND SPEED AND DESIGN CRITERIA. <br />3. TRUSSES AND RAFTERS SHALL BE SECURED TO SUPPORTS WITH HURRICANE <br />ANCHORS AND 8d NAILS, MINIMUM, TRUSS TO TRUSS CONNECTORS SHALL <br />BE BY THE TRUSS FABRICATOR INCLUDING VALLEY TRUSSES. <br />4. TRUSSES SHALL BE SECURELY BRACED DURING ERECTION AND AFTER <br />PERMANENT INSTALLATION IN ACCORDANCE WITH "BRACING WOOD TRUSSES: <br />COMMENTARY AND RECOMMENDATIONS (BWT-85)" AS PUBLISHED BY TPI, AS <br />CALLED FOR BY THE TRUSS FABRICATOR AND AS SHOWN ON DRAWINGS. <br />CONSTRUCTION AND/OR PERMANENT LOADS SHALL BE PLACED ONLY ON <br />COMPLETED NAILED SHEATHING AND BRACING. <br />5.. ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL <br />BE PRESSURE TREATED, USING WOLMAN CC OR EQUIVALENT. <br />6. THE CONTRACTOR SHALL COORDINATE ALL ROOF PENETRATIONS, DUCT LAYOUT <br />AND OTHER CEILING WORK WITH TRUSS AND OTHER STRUCTURAL FRAMING. <br />7. ALL DOORS, WINDOWS AND STOREFRONT, THEIR FRAMES, FASTENERS AND ANCHORAGES <br />SHALL SATISFY THE 150 MPH WIND SPEED REQUIREMENTS OF RFBC 2010, CHAPTFER 3. <br />8. PATIO DOORS SHALL BE SAFTY GLAZED PER RFBC 2010, SECTION R 308.4. <br />ROOF SHEATHING (UNBLOCKED) <br />USE 15/32" THICK APA RATED SHEATHING, 32/16, EXPOSURE <br />1 (OR 1/2" OSB). USE PANEL CLIPS BETWEEN EACH SUPPORT. <br />MINIMUM NAILING OF PLYWOOD SHALL BE WITH 8d COMMON NAILS <br />AT 6" O.C. AT SUPPORTED EDGES. AT 12" O.C. ALONG <br />INTERMEDIATE SUPPORTS, NAILING SHALL BE 4" O.C. FOR PERIMITERS <br />AND HIPS, FOR A 5'-0" WIDTH. ( NO STAPLES ). <br />FLOOR SHEATHING. GLUE -NAILED SUB -FLOORING <br />USE 3/4" THICK APA RATED SHEATHING, 48/24, C-D, EXPOSURE I. PANELS <br />SHALL BE TONGUE AND GROOVE EDGES. NAILING SHALL BE 8d DEFORMED <br />NAILS 0 6" O.C. ALONG EDGES AND 12" O.C. AT INTERMEDIATE <br />SUPPORTS FOR GLUE -NAILED FLOORS. USE ADHESIVES CONFORMING TO APA <br />SPEC Y510J; NON -VENEERED PANELS WITH SANDED SURFACES AND EDGES <br />SHALL USE ONLY SOLVENT BASED GLUES. <br />WALL SHEATHING <br />EXTERIOR AND INTERIOR BEARING STUD WALL SHEATHING SHALL BE 15/32" <br />THICK APA RATED, EXPOSURE I OR 1 /2" OSB. NAILING OF PLYWOOD SHALL BE 8d NAILS <br />AT 6" O.C. AT EDGES AND 12" O.C. AT INTERMEDIATE SUPPORTS, U.O.N. <br />STRUCTURAL WOOD <br />1. LUMBER FOR STRUCTURAL FRAMING AND STUD WALLS SHALL BE SURFACED <br />tad 15% M.C. MAX, KD, SOUTHERN YELLOW PINE MEETING OR EXCEEDING THE <br />FOLLOWING MINIMUM GRADES: <br />2X4 STUD WALLS - STUD GRADE <br />2X6 AND LARGER FRAMING - NO. 2 GRADE, Fb=1200 PSI, MIN. <br />4X4 POSTS STUD GRADE <br />2. MINIMUM TWO-2X STUDS UNDER ALL CONCENTRATED LOADS. <br />3. ML = MICRO -LAM BEAMS BY "TRUSJOIST", GRADE Fb = 2925 PSI <br />OPEN WEBB 4X2 WOOD FLOOR TRUSSES, SHALL BE 16" DEEP BY <br />TRUSJOIST-MACILLAN WITH INSTALLATION IN ACCORDANCE WITH <br />RECOMMENDATIONS AND GUIDLINES OF THE VENDOR. PROVIDE STRUT <br />BRACING, BRIDGING AND BLOCKING AS REQUIRED OR SHOWN. SHOP DRAWINGS <br />SHALL BE SUBMITTED FOR THE ENGINEERS REVIEW. PERMANANT BRACING, <br />BRIDGING AND SHEATHING SHALL BE INSTALLED PRIOR TO FLOOR LOADS. <br />4. ALL FRAMING CONNECTIONS SHALL BE BASED ON (USP) LUMBER CONNECTORS. <br />NAILING REQUIEMENT LITERATURE. A CATALOG OF CONNECTORS SHALL BE <br />KEPT ON SITE AT ALL TIMES AND REFERED TO BY THE FRAMING <br />SUBCONTRACTOR. ALL NAILS AND CONNECTORS EXPOSED TO THE ATMOSPHERE <br />SHALL BE GALVANIZED. <br />5. PROVIDE WOOD FRAME SUPPORT AND ACCESS PLATFORM ABOVE BOTTOM TRUSS <br />CHORDS AS REQUIRED BY MECHANICAL CONTRACTOR. CONTRACTOR SHALL VERIFY <br />LOCATIONS AND PROVIDE ROOF TRUSS FABRICATOR WITH LOADS, INSTALLATION <br />DIMENSIONS AND CLEARANCE REQUIREMENTS NECESSARY FOR TRUSS DESIGN AND <br />MODIFICATIONS TO STANDARD TRUSSES. <br />ASSUMED ALLOWABLE SOIL BEARING PRESSURE = 2000 PSI <br />1UILDING SLAB AND FOOTING SUBGRADES INCLUDING ALL FILL SHALL BE COMPACTED <br />TO 95% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY AT OPTIMUM MOISTURE <br />PER ASTM D-1557. SOIL SHALL BE GRANULAR MATERIAL CONTAINING LESS THAN <br />11 % OF FINES PASSING A #200 SIEVE. DENSITY TESTING AT CONTRACTORS OPTION. <br />DESIGN CRITERIA AND STRUCTURAL NOTES <br />1. ALL WORK SHALL BE IN ACCORDANCE WITH THE RESIDENTIAL FLORIDA BUILDING <br />CODE 2010, LOCAL ORDINANCE AND REGULATIONS. <br />2. LIVE LOADS <br />ROOF = 30 PSF <br />FLOOR = 40 PSF <br />DEAD LOADS: <br />ROOF -TOP CHORDS = 7.5 PSF, BOTTOM CHORD = 10 PSF <br />FLOOR = 20 PSF <br />3. WIND LOADS: 150 MPH WIND SPEED = 25 PSF, BASIC <br />DESIGN PER RFBC 2010. <br />4. MATERIALS OF CONSTRUCTION AND NOTES <br />ALL CONCRETE TO BE IN ACCORDANCE WITH "BUILDING CODE REQUIREMENTS <br />FOR REINFORCED CONCRETE" (ACI 318-95). <br />ALL CONCRETE ------ f'c = 2,500 PSI, 5" SLUMP MAX, FILLED CELLS <br />2,500 PSI, "PEAROCK CONCRETE", 9" SLUMP MAX. USE WATER OR CURING <br />COMPOUND FOR SLAB -ON -GRADE AND PLACE NO CONSTRUCTION MATERIALS <br />THEREON UNTIL CONCRETE HAS REACHED 2/3 OF ITS COMPRESSIVE STRENGTH. <br />CONCRETE TESTING AT CONTRACTOR'S OPTION. <br />ALL REINFORCING STEEL SHALL HAVE A MINIMUM YIELD STRENGTH OF 60,000 PSI <br />AND SHALL CONFORM TO ASTM A-615. LAP SPLICE BARS 25 TIMES. <br />ALL WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 82-02.. <br />MASONRY <br />1. HOLLOW REGULAR WEIGHT CONCRETE MASONRY UNITS EIGHT 8 INCHES AND OVER <br />IN WIDTH SHALL CONFORM TO STANDARD SPECIFICATIONS FOR HOLLOW LOAD - <br />BEARING CONCRETE MASONRY UNITS, GRADE N-11 CONFORMING TO ASTM C90-03, <br />WITH A 28 DAY COMPRESSIVE STRENGTH OF NOT LESS THAN 1,500 PSI, f'rn <br />(net section area). <br />2. BRACE HOUSE WALLS UNTIL FILL AND CONCRETE FLOOR SLAB ARE INSTALLED. <br />3. MORTAR MIXES SHALL MEET ASTM C-270-04, PROPORTION PER THE FOLLOWING TYPES: <br />TYPE S (1,800 PSI) OR M (2,500 PSI). <br />4. CELLS CONTAINING VERTICAL REINFORCING BARS SHALL BE FILLED WITH 'PEAROCK" <br />CONCRETE AT A 28 DAY COMPRESSIVE STRENGTH OF 2,500 PSI AND CONTAINING <br />NOT LESS THAN 5 BAGS OF CEMENT PER CUBIC YARD AND A SLUMP OF <br />9 INCHES MAXIMUM. <br />NOTE: VARIOUS ITEMS WITHIN THE GENERAL <br />NOTES DO NOT APPLY TO THIS PROJECT. <br />ADDRESS: <br />5930 8TH. STREET <br />ZEPHYRHILLS, FLORIDA 33542 <br />UTI LITI ES: <br />WATER -- PUBLIC <br />SEWER - PUBLIC <br />BSBL=BUILDING SETBACK LINE <br />I <br />LOCATION TAP <br />NTS <br />THE <br />PROJECT <br />CONSISTS <br />OF <br />MODIFING <br />THE <br />EXISTING <br />BURNED <br />OUT <br />BUILDING. <br />0 <br />NO TITLE SEARCH HAS BEEN DONE ON THIS PROPERTY <br />PIN NO. 1 1 26-21-0010-00700-0220 <br />NO WETLANDS ON SITE <br />BEFORE DIGGING CALL <br />SUNSHINE STATE ONE -CALL OF FLA <br />1-800-432-4770 <br />FSS 93.240, SECTIONS 556,101-556.111 <br />REQUIRES MIN. OF 2 DAYS AND MAX, OF <br />5 DAYS NOTICE BEFORE YOU EXCAVATE. <br />? . <br />?EP <br />(ACI Nk <br />ALLWOZKSHTALI COMPLY WITH ALL <br />I?REVAILI G 'CO. ES, FL('1; RDA BUILDIGNG <br />CODE,NNAT}4{ Nr",I.I'LECTIUICCODEAND <br />CITY OF INANCES <br />�� V' <br />�C) <br />M1� <br />1sCODE: <br />1.1 RE FLORIDA BUILDING CODE 2010 <br />1.1.1 RISK CATEGORY I <br />FRONT AND REAR PORCHES) <br />1.1.2 RISK CATEGORY li <br />(RESIDENCE) <br />ENCLOSED STRUCTURES <br />1.2 BUILDING CODE REQUIREMENTS FOR <br />REINFORCED CONCRETE (ACI 318-08) <br />1.3 "DESIGN SPECIFICATION FOR LIGHT <br />METAL PLATES CONNECTED TO WOOD <br />TRUSSES" BY THE TRUSS PLATE <br />INSTITUTE (TPI) LATEST EDITION. <br />2. DESIGN CRITERIA: <br />2.1 DWELLING FLOORS-40 PSF LIVE LOAD <br />PLUS 20 PSF DEAD LOAD. <br />2.2 BALCONIES-40 PSF LIVE LOAD PLUS <br />15 PSF DEAD LOAD. <br />2.3 ROOF OVER LIVING AREAS-30 PSF <br />LIVE LOAD, 17 PSF (7 PSF T/C AND <br />10 PSF B/C DEAD LOAD FOR SHINGLE <br />ROOFS. <br />2.4 WIND - 150 MPH 3 SECONDS <br />GUST, EXPOSURE "B", IMPORTANCE <br />FACTOR 1.0. <br />2.5 NET UPLIFT DEAD LOADS-10 PSF <br />SHINGLES, 15 PSF TILE. <br />2.6 INTERIOR DOORS BY THERMA-TRU, O.E. <br />3'X6'8" DP = +80.0 & (-)80.0 <br />FC = FL11483.6 <br />2.7 ALENCO WINDOW, NON -IMPACT SINGLE <br />HUNG 900 SERIES, LOW "E" <br />SH25 DP = +41.0 & (-)41.0 - O.E. <br />FC = FL10788.1 <br />O.E. = OR EQUAL <br />DRA WING INDEX <br />1. SITE PLAN, NOTES AND DRA WING <br />2. EXISTING FLOOR AND DEMO PLAN <br />3, EXISTING ELEVA TIONS <br />4. PROPOSED FLOOR PLAN <br />5. PROPOSED ELEVATIONS <br />6. FO UNDATION PLAN <br />7. PL UMBING PLAN <br />B. ELECTRIC PLAN <br />9. A%C PLAN <br />10. TRUSS PLAN <br />11. CONCRETE DETAILS <br />12. WOOD DETAILS <br />13. SHINGLE DETAILS <br />14. PRODUCT CODES <br />The contractor shall verify all plans and existing dimensions <br />and conditions on the jab site and shall immediately notify <br />the engineer in writing of any discrepancies before <br />proceeding with the work or be responsible for some. <br />Emails: rroberts.egiOgmail.com troutwein_clem@outlook.com <br />ENsfi•N= <br />No.427s2 . <br />STA E OP <br />MV10A <br />Digitally signed by William H <br />Roberts, PE <br />DN: cn=William H Roberts, <br />PE, o=EGi, ou=Engineering, <br />email=rroberts.egi@gmail.c <br />On C=US <br />Date: 2013.09.01 16:46.43 <br />-04'00' <br />I HEREBY CERMY: <br />THAT THE CONSTRUCTION PLANS SHOWN ARE IN COMPLIANCE <br />WITH CHAPTER 16, SECTION 1609 OF THE 2010 FLORIDA BUILDING CODE <br />FOR 150 MPH ULTIMATE DESIGN WIND SPEED (RISK CATEGORY 11) <br />ALONG WITH THE EN71RE 2010 FLORIDA BUILDING CODE, RESIDENTIAL <br />EGI-ENGINEERING GREAT IDEAS, LLC <br />William H. Roberts, P.E. <br />1808 James Redman Parkway <br />No. 306 <br />Plant City, Florida 33563 <br />P.E. #42712 <br />TEL (813) 334-0271 <br />CA #29098 <br />8-26-13 <br />DATE <br />OT VALID WITHOUT FOR SEAL OR STAMP) <br />NEEMEW <br />■■■■■.. <br />�■NEENE <br />j <br />wMO <br />,. <br />r <br />r r <br />• ` <br />_ <br />r1 s ' <br />ME <br />■o <br />E01 <br />■ <br />o <br />■� <br />■� <br />ON <br />■i <br />■E <br />�,I ■� <br />.� <br />�1 <br />■I <br />It <br />■I <br />IN <br />■ <br />IN <br />IN <br />NONE <br />SOME <br />N■WE■M■■■ <br />I <br />CN <br />,. <br />i <br />• <br />ry <br />+i <br />.. . <br />i <br />♦ 0 <br />LLJ <br />.N <br />r <br />I� <br />4%)1 <br />mmuw <br />DRAVN <br />CLEM TRAUTWEIN <br />scask <br />NTS <br />CHECKED &APPROVED <br />CET 8-22 <br />C I 354d <br />SHEET OF <br />