Laserfiche WebLink
CODES AND STANDARDS <br />CONCENTRATED LOADS SHALL NOT BE PLACED ATOP TRUSSES UNTIL ALL SPECIFIED BRACING HAS BEEN INSTALLED <br />* STRUCT DESIGN BASED ON THE 6TH EDITION (2017) FLORIDA BUILDING CODE <br />AND DECKING IS PERMANENTLY NAILED IN PLACE. SPECIFICALLY AVOID STACKING FULL BUNDLES OF DECKING OR <br />* lvll M I ESIGN LOADS FOR BUILDINGS & OTHER STRUCTURES ASCE 7 <br />OTHER HEAVY MATERIALS ONTO UNSHEATHED TRUSSES. <br />* BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE ACI 318 <br />* ERECTION BRACING IS ALWAYS REQUIRED. PROFESSIONAL ADVICE SHOULD ALWAYS BE SOUGHT TO PREVENT <br />TOPPLING OR "DOMINOING" (CASCADING COLLAPSE) OF TRUSSES DURING INSTALLATION. <br />! *BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES ACI 530 <br />PASSAGE DOORS <br />* AISC SPECIFICATION FOR STRUCTURAL STEEL DESIGN <br />* NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION <br />*ALL INTERIOR DOORS SHALL BE UNDERCUT 1/2 "FOR AIR CONDITIONER RETURN AIR. <br />* AF&PA WOOD FRAME CONSTRUCTION MANUAL <br />* HINGES WITH HINGE PINS EXPOSED TO THE OUTSIDE OF ALL EXTERIOR DOORS SHALL HAVE NON -REMOVABLE <br />PINS. <br />GENERAL <br />* SWINGING DOORS, WHERE OF SOLID CORE TYPE CONSTRUCTION, SHALL BE NOT LESS THAN 1.75 INCHES IN <br />* DO NOT SCALE DRAWINGS, USE GIVEN DIMENSIONS ONLY. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER <br />THICKNESS. <br />SCALE DIMENSIONS AT ALL TIMES. ANY DISCREPANCIES SHOULD BE BROUGHT TO THE DESIGNER IMMEDIATELY. <br />* EXTERIOR EXIT DOORS, IF OPERABLE FROM THE EXTERIOR, SHALL HAVE AT LEAST ONE LOCK THAT IS KEY <br />* ALL DIMENSIONS MUST BE VERIFIED BY THE CONTRACTOR IN THE FIELD. THE DIMENSIONS SHOWN ARE AS <br />OPERATED FROM THE EXTERIOR. <br />ACCURATE AS THE BASE BUILDING DOCUMENTS PERMIT. ANY MAJOR DISCREPANCIES MUST BE BROUGHT TO THE <br />LOCKS ON EXTERIOR DOORS SHALL HAVE A MINIMUM OF 6,000 POSSIBLE KEY CHANGES OR LOCKING <br />ATTENTION OF THE DESIGNER IMMEDIATELY. <br />COMBINATIONS. <br />* THE CONTRACTOR IS RESPONSIBLE FOR ALL METHODS, PROCEDURES, AND SEQUENCES OF CONSTRUCTION. <br />* WHERE A KEY -IN -THE -KNOB LATCH -SET IS SPECIFIED THERE SHALL BE AN AUXILIARY DEAD BOLT TYPE LOCK <br />CONSTRUCTION SITE SAFETY, INCLUDING ALL ADEQUATE TEMPORARY BRACING AND SHORING, IS THE SOLE <br />PROVIDED. <br />RESPONSIBILITY OF THE CONTRACTOR. <br />* DEAD BOLTS SHALL BE HARDENED OR CONTAIN INSERTS. <br />* IT IS THE CONTRACTORS RESPONSIBILITY TO EMPLOY THE NECESSARY PROFESSIONAL SERVICES TO DETERMINE <br />THE NECESSARY METHODS AND SUPPORTS REGARDING FORMING AND CONSTRUCTION LOADS. <br />* FRONT MAIN ENTRANCE DOOR SHALL BE PROVIDED WITH A DOOR SCOPE OF VISION PANEL. <br />* THE CONTRACTOR SHALL COORDINATE THE STRUCTURAL WORK WITH THE WORK OF ALL OTHER TRADES. <br />* EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN THE DOOR FROM INSIDE THE CLOSET. <br />* ALL WORK SHALL BE OF THE HIGHEST QUALITY FOLLOWING THE MANUFACTURER'S SPECIFICATIONS ALONG WITH <br />* EVERY BATHROOM DOOR SHALL BE DESIGNED TO ALLOW OPENING FROM THE OUTSIDE DURING AN EMERGENCY <br />THE BEST TRADE PRACTICES AND STANDARDS. <br />WHEN LOCKED. <br />* ALL WORK AND MATERIALS SHALL BE GUARANTEED AGAINST POOR WORKMANSHIP AND DEFECTS. <br />* ALL EXTERIOR GLASS DOORS TO BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA 101/1S2 STANDARD <br />AND BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE CHARACTERISTICS AND <br />* DRAWINGS ARE TO BE ISSUED TO THE SUBCONTRACTORS IN COMPLETE SETS SO THAT THEY KNOW THE <br />APPROVED PRODUCT TESTING ENTITY. <br />ARCHITECTURAL DETAILS AFFECTING THEIR WORK. <br />* EXTERIOR DOORS INSTALLED IN MASONRY WALLS WERE BUCK THICKNESS IS LESS THAN 1-1/2 " SHALL BE <br />* THE CONTRACTOR IS RESPONSIBLE FOR ALL SPECIALTY TRADES. ANY AND ALL TRADES NOT MENTIONED IN THESE <br />ANCHORED THROUGH THE JAMB INTO THE STRUCTURAL SUBSTRATE. <br />DRAWINGS ARE THE RESPONSIBILITY OF THE CONTRACTOR. <br />* ALL WORK SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF THE FLORIDA BUILDING CODE OR THESE <br />WINDOWS <br />DRAWINGS - WHICHEVER IS MORE STRINGENT. <br />* HINGES WITH HINGE PINS EXPOSED TO OUTSIDE, OF ALL EXTERIOR OPERABLE WINDOWS AND SKYLIGHTS SHALL <br />* ALL WINDOW AND DOOR OPENING SIZES ARE NOMINAL. VERIFY MANUFACTURER'S ACTUAL OPENING <br />HAVE NON -REMOVABLE PINS, OR SHALL BE OF INTERLOCKING STUD TYPE AND SUCH HINGES SHALL HAVE <br />REQUIREMENTS. <br />NON -EXPOSED SCREWS. <br />DESIGN <br />* ALL WINDOWS SHALL BE CONSTRUCTED SO THAT WHERE FIXED OR LOCKED THEY CANNOT BE REMOVED FROM <br />THE FRAMES FROM THE OUTSIDE. <br />* LIVE LOADS <br />* EXTERIOR WINDOWS SHALL BE LOCKED ON THE INSIDE WITH DEVICES CAPABLE OF WITHSTANDING A FORCE OF <br />FLOOR 40 PSF <br />150 LBS. APPLIED IN ANY OPERABLE DIRECTION UNLESS THE WINDOW OPENING IS PROTECTED BY OTHER <br />ATTIC 20 PSF <br />INTRUSION SECURITY DEVICES AS SET FORTH HEREIN, OR AN APPROVED EQUAL, <br />ROOF 20 PSF <br />* EGRESS WINDOWS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF TOOLS AND SHALL PROVIDE A <br />BALCONY 60 PSF <br />CLEAR OPENING OF NOT LESS THAN 201N IN WIDTH, 241N IN HEIGHT, AND 5.7 SQUARE FEET IN AREA. THE BOTTOM <br />OF THE OPENING SHALL BE NOT MORE TH <br />AN HAN 441N ABOVE THE FLOOR AND ANY LATCHING DEVICE SHALL BE <br />* DEAD LOADS: SPECIFIED MATERIAL WEIGHTS UTILIZED - REFERENCE DRAWINGS FOR SPECIFIED SUPERIMPOSED <br />CAPABLE OF BEING OPERATED FROM NOT MORE THAN 541N ABOVE THE FINISHED FLOOR. <br />DEAD LOADS FOR SPECIALTY STRUCTURAL SYSTEMS. <br />* ALL EXTERIOR WINDOWS TO BE TESTED IN ACCORDANCE WITH ANSI/AMMA/NWWDA 101/1S2 STANDARD AND <br />* WIND LOADS: REFERENCE WIND DESIGN INFORMATION WITHIN THESE PLANS. <br />BEAR AN AMMA OR WDMA LABEL IDENTIFYING THE MANUFACTURER, PERFORMANCE CHARACTERISTICS AND <br />WOOD <br />APPROVED PRODUCT TESTING ENTITY. <br />* ALL FRAMING TO COMPLY WITH THE FBC (CURRENT EDITION) UNLESS THESE PLANS NOTE OTHERWISE <br />* ALL EXTERIOR WINDOWS TO BE ANCHORED PER THE PUBLISHED MANUFACTURER'S RECOMMENDATIONS TO <br />* ALL METAL CONNECTION HARDWARE BY SIMPSON UNLESS PRE -APPROVED BY THE ENGINEER <br />ACHIEVE THE DESIGN PRESSURE SPECIFIED. <br />* WOOD IN CONTACT WITH EARTH, MASONRY, AND CONCRETE SHALL BE PRESSURE TREATED IN ACCORDANCE <br />* EXTERIOR WINDOWS INSTALLED IN MASONRY WALLS WERE BUCK THICKNESS IS LESS THAN 1-1/2" SHALL BE <br />WITH A M UNLESS A WATER BARRIER IS PROVIDED. WATER BARRIER SHALL BE IN ACCORDANCE WITH THE FBC <br />ANCHORED THROUGH THE JAMB INTO THE STRUCTURAL SUBSTRATE. <br />MINI <br />OR AT A MINIMUM 30L6 FELT. <br />* EXTERIOR WINDOW MULLIONS AND ADJACENT DOOR ASSEMBLIES ARE REQUIRED TO BE TESTED OR ENGINEERED <br />* COVER WOOD PRODUCTS TO PROTECT AGAINST MOISTURE. SUPPORT STACKED PRODUCTS TO PREVENT <br />TO TRANSFER 1.5 TIMES THE DESIGNED LOADS TO THE ROUGH OPENING SUBSTRATE. <br />DEFORMATION AND TO ALLOW AIR CIRCULATION. <br />INSULATION <br />* CONCEALED DIMENSIONAL LUMBER: 1) GRADING AGENCY: SOUTHERN PINE INSPECTION BUREAU, INC. (SPIB). 2) <br />* UNLESS OTHERWISE NOTED - ALL THERMAL INSULATION SHALL BE AS FOLLOWS: <br />SIZES: NOMINAL SIZES AS INDICATED ON DRAWINGS, S4S. 3) MOISTURE CONTENT: S-DRY OR MC19. 4) <br />CONCRETE MASONRY WALLS R-6 INSULATION <br />MISCELLANEOUS BLOCKING, FURRING, AND NAILERS AS FOLLOWS - LUMBER: S4S NO. 2 OR STANDARD GRADE - <br />FRAMED WALLS R-13 FIBERGLASS BATT <br />BOARDS: STANDARD OR NO. 3. <br />- <br />* EXPOSED DIMENSIONAL LUMBER: 1) GRADING AGENCY: SOUTHERN PINE INSPECTION BUREAU, INC. (SPIB). 2) <br />INTERIOR CEILINGS R-19 FIBERGLASS BATT OR BLOWN <br />SIZES: NOMINAL SIZES AS INDICATED ON DRAWINGS, S4S. 3) MOISTURE CONTENT: S-DRY OR MC19. <br />CEILINGS UNDER ATTIC R-38 FIBERGLASS BATT OR BLOWN <br />* CONSTRUCTION PANELS: 1) CONCEALED PLYWOOD: PS 1, C-C PLUGGED, EXTERIOR GRADE. 2) EXPOSED <br />PLYWOOD: PS 1, A-D, INTERIOR GRADE. 3) ELECTRICAL COMPONENT MOUNTING: APA RATED SHEATHING, FIRE <br />RETARDANT TREATED. <br />* FASTENERS: HOT -DIPPED GALVANIZED STEEL FOR HIGH HUMIDITY AND TREATED WOOD LOCATIONS, UNFINISHED <br />STEEL ELSEWHERE U.N.O. <br />WOOD CONNECTORS <br />* UNLESS OTHERWISENOTED IN THE MANUFACTURER'S CATALOG, BOLTS AND NAILS SHALL NOT BE COMBINED. <br />* ALL NAILS SHALL BE COMMON UNLESS OTHERWISE NOTED IN THE MANUFACTURER'S CATALOG OR SUBSTITUTED, <br />BY THE ENGINEER -OF RECORD, WITH A REDUCTION TAKEN. <br />* UNLESS OTHERWISE NOTED IN THE MANUFACTURER'S CATALOG, BENDING STEEL IN.THE FIELD MAY CAUSE <br />FRACTURES AT THE BEND LINE. FRACTURED STEEL WILL NOT CARRY LOAD AND MUST BE REPLACED. WHEN <br />BENDING IS ALLOWED OR REQUIRED IN THE CATALOG, THE CONNECTOR SHALL BE ALLOWED ONE CYCLE BEND, <br />ONE TIME ONLY. <br />* ALL CONNECTORS IN CONTACT WITH PRESSURE TREATED WOOD OR EXPOSED TO WEATHER SHALL BE HOT <br />DIPPED GALVANIZED WITH MINIMUM G180 PROTECTION. ALL NAILS, SCREWS, BOLTS, ETC REQUIRED FOR THE <br />CONNECTOR SHALL HAVE AN EQUAL OR GREATER PROTECTION AS THE CONNECTOR. DO NOT MIX GALVANIZED <br />AND STAINLESS STEEL MATERIALS. <br />* A FASTENER THAT SPLITS THE WOOD WILL NOT TAKE THE DESIGN LOAD. EVALUATE SPLITS TO DETERMINE IF THE <br />CONNECTION WILL PERFORM AS REQUIRED. DRY WOOD MAY SPLIT MORE EASILY AND SHOULD BE EVALUATED AS <br />REQUIRED. IF WOOD TENDS TO SPLIT, CONSIDER PRE -BORING HOLES WITH DIAMETERS NOT EXCEEDING 0.75 OF <br />THE NAIL DIAMETER (1997 NDS 12.1.3.1). <br />* BUILT-UP LUMBER (MULTIPLE MEMBERS) MUST BE FASTENED TOGETHER TO ACT AS ONE UNIT TO RESIST THE <br />° APPLIED LOAD. <br />* UNLESS OTHERWISE NOTED IN THE MANUFACTURER'S CATALOG, FILL ALL FASTENER HOLES WITH FASTENER TYPES <br />AS SPECIFIED IN THE MANUFACTURER'S CATALOG. <br />L <br />* ALL SPECIFIED FASTENERS MUST BE INSTALLED ACCORDING TO THE INSTRUCTIONS IN THE MANUFACTURER'S <br />CATALOG. <br />* BOLT HOLES SHALL BE A MINIMUM OF 1/32" AND A MAXIMUM OF 1/16 " LARGER THAN THE BOLT DIAMETER <br />(NDS 8.1.2.1) <br />* INSTALL ALL SPECIFIED FASTENERS BEFORE LOADING THE CONNECTION. <br />* NAIL TOOLS WITH HOLE -LOCATION MECHANISMS MAY BE USED TO INSTALL CONNECTORS, PROVIDED THE <br />CORRECT QUANTITY AND TYPE OF NAILS ARE PROPERLY INSTALLED IN THE NAIL HOLES. <br />* JOIST SHALL BEAR COMPLETELY ON THE CONNECTOR SEAT, AND THE GAP BETWEEN THE JOIST END AND THE <br />HEADER SHALL NOT EXCEED 1/8 ". <br />ROOF (METAL) <br />ROOF SHEATHING SHALL BE MIN 112, PLYWOOD APA RATED EXPOSURE 1 C-D WOOD STRUCTURAL PANELS AND <br />SHALL SPAN NO MORE THAN 2'4'. SHEATHING SHALL SPAN WITH THE LONG DIMENSION PERPENDICULAR TO <br />FRAMING WITH THE END JOINTS STAGGERED FASTEN SHEATHING WITH 8D COMMON RING -SHANK NAILS @ 6,cc <br />MINIMUM U.N.O. FASTEN SHEATHING WITH 8D COMMON NAILS @ 4;Cc MINIMUM WITHIN ALL END ZONES - FOR <br />END ZONE DIMENSIONS AND LOCATIONS, SEE WIND DESIGN SECTION WITHIN THESE PLANS. FASTEN SHEATHING <br />WITH 8D RING -SHANK NAILS @ 4;cc MINIMUM WITHIN ALL CORNERS OF OVERHANGS - FOR OVERHANG CORNER <br />LOCATIONS, SEE WIND DESIGN SECTION WITHIN THESE PLANS. FASTEN SHEATHING WITH 8D RING -SHANK NAILS @ <br />4-cc FOR A LENGTH OF 4'-0. PERPENDICULAR TO EACH GABLE END. UNDERLAYMENT SHALL CONFORM TO ASTM <br />D226 TYPE 1 OR ASTM 4869 TYPE 1. FOR ROOF SLOPES FROM 2:12 UP TO 4:12, UNDERLAYMENT SHALL BE A <br />MINIMUM OF TWO LAYERS APPLIED AS FOLLOWS: (1) STARTING AT THE EAVE, A 19-INCH STRIP OF UNDERLAYMENT <br />SHALL BE APPLIED PARALLEL WITH THE EAVE AND FASTENED SUFFICIENTLY TO STAY IN PLACE. (2) STARTING AT THE <br />EAVE, 36-INCH-WIDE STRIPS OF UNDERLAYMENT FELT SHALL BE APPLIED OVERLAPPING SUCCESSIVE SHEETS 19 <br />INCHES AND FASTENED SUFFICIENTLY TO STAY IN PLACE. <br />FOR ROOF SLOPES 4:12 OR GREATER, UNDERLAYMENT SHALL,,BE A MINIMUM OF ONE LAYER OF UNDERLAYMENT <br />FELT APPLIED AS FOLLOWS: (1) STARTING AT THE EAVE, UNDERLAYMENT SHALL BE APPLIED SHINGLE FASHION <br />PARALLEL TO THE EAVE, LAPPED 2 INCHES (51 MM), AND FASTENED SUFFICIENTLY TO STAY IN PLACE. METAL ROOF <br />SHALL BE IN ACCORDANCE WITH SECTION 1507 OF THE FBC. <br />WOOD TRUSS FRAMING SYSTEM <br />* TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THESE SPECIFICATIONS AND WHERE ANY APPLICABLE DESIGN <br />FEATURE IS NOT SPECIFIED HEREIN, DESIGN SHALL BE IN ACCORDANCE WITH APPLICABLE PROVISIONS OF LATEST <br />EDITION OF NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION (NDS) AMERICAN FOREST AND PAPER <br />ASSOCIATION (AFPA), AND DESIGN SPECIFICATIONS FOR METAL PLATE CONNECTED WOOD TRUSSES (ANSI/TPI 1), <br />TRUSS PLATE INSTITUTE (TPI), AND CODE OF JURISDICTION. <br />* fvIANUFACTURER SHALL FURNISH DESIGN AND PLACEMENT DRAWINGS BEARING SEAL AND REGISTRATION <br />NUMBER OF A STRUCTURAL ENGINEER LICENSED IN STATE WHERE TRUSSES ARE TO BE INSTALLED. DRAWINGS <br />SHALL BE APPROVED BY ENGINEER OF RECORD PRIOR TO FABRICATION. <br />* TRUSS DESIGN DRAWINGS SHALL INCLUDE AS MINIMUM INFORMATION: SPAN, DEPTH OR SLOPE AND SPACING <br />OF TRUSSES REQUIRED BEARING WIDTH DESIGN LOADS, AS APPLICABLE: (1) TOP CHORD LIVE LOAD; (2) TOP CHORD <br />DEAD LOAD; (3) BOTTOM CHORD LIVE LOAD; (4). BOTTOM CHORD DEAD LOAD; (5) CONCENTRATED LOADS AND <br />THEIR POINTS OF APPLICATION; AND (6) WIND AND SEISMIC CRITERIA; ADJUSTMENT TO LUMBER AND PLATE <br />DESIGN LOADS FOR CONDITION OF USE REACTIVE FORCES, THEIR POINTS OF OCCURRENCE AND DIRECTION PLATE <br />TYPE, GAGE, SIZE AND LOCATION OF PLATE AT EACH JOINT LUMBER SIZE, SPECIES AND GRADE FOR EACH MEMBER <br />LOCATION OF ANY REQUIRED CONTINUOUS LATERAL BRACING CALCULATED DEFLECTION RATIO AND/OR MAXIMUM <br />DEFLECTION FOR LIVE AND TOTAL LOAD MAXIMUM AXIAL COMPRESSIVE FORCES IN TRUSS MEMBERS LOCATION OF <br />JOINTS CONNECTION REQUIREMENTS FOR: (1) TRUSS TO TRUSS GIRDERS, (2) TRUSS PLY TO PLY, AND (3) FIELD <br />SPLICLS. <br />LUMBER USED FOR TRUSS MEMBERS SHALL BE IN ACCORDANCE WITH PUBLISHED VALUES OF LUMBER RULES <br />WRITING AGENCIES APPROVED BY BOARD OF REVIEW OF AMERICAN LUMBER STANDARDS COMMITTEE. LUMBER <br />SHALL. BE IDENTIFIED BY GRADE MARK OF A LUMBER INSPECTION BUREAU OR AGENCY APPROVED BY THAT BOARD, <br />AND SHALL BE AS SHOWN ON DESIGN DRAWINGS. <br />MOISTURE CONTENT OF LUMBER SHALL BE NO LESS THAN 7 PERCENT NOR GREATER THAN 19 PERCENT AT TIME OF <br />FABRICATION. <br />* ADJUSTMENT OF VALUES FOR DURATION OF LOAD OR CONDITIONS OF USE SHALL BE IN ACCORDANCE WITH <br />NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION (NDS). <br />* FIRE RETARDANT TREATED LUMBER, IF APPLICABLE, SHALL MEET SPECIFICATIONS OF TRUSS DESIGN AND ANSI/TPI <br />1-1995, PAR 9.1.5 AND SHALL BE RE -DRIED AFTER TREATMENT IN ACCORDANCE WITH AWPA STANDARD C20. <br />ALLOWABLE VALUES MUST BE ADJUSTED IN ACCORDANCE WITH NDS PAR 2.3.6. LUMBER TREATED SHALL SUPPLY <br />CERTIFICATE OF COMPLIANCE. <br />* METAL CONNECTOR PLATES SHALL BE MANUFACTURED BY ALPINE/I-UMBERMATE/CLERY AND SHALL BE NOT LESS <br />T HA;"I .03o INCHES IN THICKNESS (20 GAGE) AND SHALL MEET OR EXCEED ASTM A653-94 GRADE 37, AND SHALL BE <br />HOT DIPPED GALVANIZED ACCORDING TO ASTM A653-94, COATING DESIGNATION G60. WORKING STRESSES IN <br />STEEL ARE TO BE APPLIED TO EFFECTIVE RATIOS FOR PLATES AS DETERMINED BY TEST IN ACCORDANCE WITH <br />APPENDIX E AND F OF ANSI/TPI 1-1995. <br />* IN HIGHLY CORROSIVE ENVIRONMENTS, SPECIAL APPLIED COATINGS OR STAINLESS STEEL MAY BE REQUIRED. <br />* CUTTING AND ALTERING OF TRUSSES IS NOT PERMITTED. <br />EXISTING BUILDINGS - 6th EDITION 2017 FBC <br />NOTE: <br />REPAIRS (CHAPTER 6) <br />THE DESIGNER - TO THE BEST OF HIS OR HER ABILITY - HAS <br />PROVIDED INFORMATION WITHIN THESE DRAWINGS THAT <br />*THIS PROJECT HAS SUSTAINED LESS THAN SUBSTANTIAL STRUCTURAL DAMAGE AND THEREFORE DAMAGED <br />REPRESENTS EXISTING CONDITIONS. ANY DESCREPENCIES <br />ELEMENTS SHALL BE PERMITTED TO BE RESTORED TO THEIR PRE -DAMAGE CONDITION IN ACCORDANCE WITH <br />BETWEEN ACTUAL FIELD CONDITIONS AND THESE DRAWINGS <br />SECTION 606.2.1 <br />SHOULD BE BROUGHT TO THE DESIGNERS ATTENTION <br />IMMEDIATELY. THE GENERAL CONTRACTOR SHALL VERIFY ALL <br />EXISTING FIELD CONDITIONS SUCH AS (BUT NOT LIMITED TO) <br />DIMENSIONS, ELEVATIONS, WINDOW AND DOOR SIZES, EXTERIOR <br />AND INTERIOR FINISHES, TRUSS LAYOUT, ROOF SLOPE AND <br />OVERHANG, ELECTRICAL AND HVAC REQUIREMENTS. THE REPAIRS <br />OUTLINED WITHIN THESE DRAWINGS SHALL CONFORM TO THE <br />FLORIDA BUILDING CODE - EXISTING BUILDINGS - REPAIRS. ALL <br />REPAIR MATERIALS AND COMPONENTS SHALL MATCH ALL <br />EXISTING FINISHES AND MEET THE REQUIREMENTS OF THE <br />FLORIDA BUILDING CODE - THE MORE STRINGENT SHALL APPLY. <br />SYMBOL DEFINITIONS IONS <br />EARTH - CLEAN COMPACTED <br />FILL - SEE GENERAL NOTES <br />SECTION CALL <br />FOR REQUIREMENTS. <br />ECTION CALL NUMBER <br />STEEL - SEE GENERAL NOTES <br />FOR REQUIREMENTS AND <br />1 1 <br />CORROSION PROTECTION. <br />RAWING NUMBER <br />REFERENCED <br />WOOD BEARING <br />ELEVATION CALL <br />WALL - SEE DETAILS <br />FOR REQUIREMENTS. <br />LEVATION CALL NUMBER <br />1A <br />1.1 <br />STUCCO -SEE GENERAL NOTES FOR <br />REQUIREMENTS - STUCCO FINISH TO <br />RAWING NUMBER <br />MATCH EXISTING OR CHOSEN BY <br />REFERENCED <br />OWNER. <br />DETAIL CALL <br />CONCRETE - SEE <br />TAIL CALL LETTER <br />.. ; •• <br />GENERAL NOTES <br />' '• <br />FOR REQUIREMENTS. <br />AREA <br />DETAILED <br /><RAVVING <br />CONCRETE MASONRY UNIT WALL <br />CONSTRUCTION -SEE GENERAL <br />NUMBER <br />REFERENCED <br />NOTES FOR REQUIREMENTS AND <br />GROUT SPECIFICATIONS. <br />FASTENER SCHEDULE FOR STRUCTURAL MEMBERS <br />DESCRIPTION OF BUILDING <br />NUMBER AND TYPE OF FASTENER <br />ELEMENTS <br />SPACINGOF FASTENERS <br />a,b,c <br />Joist to sill or girder, toe nail <br />3-8d (2-1/2" x 0.113") - <br />1°' x 6" subfioor or less to each joist, <br />2-8d (2-1/2' x 0.113") <br />face nail <br />2" subfloor to foist or girder, blind <br />2-16d (3-1/2" x 0.135") - <br />and face nail <br />Sole plate to joistor blocking, face <br />16d (3-1/2" x 0.135") 16" D.C. <br />nail <br />Top or sole plate to stud, end nail <br />2-16d (3-1/2' x 0.135") - <br />Stud to sole plate, toe nail <br />3-8d or 2-16d (3-1/2" x 0.135") - <br />Double studs, face nail <br />10d (3" x 0.129") <br />Double top plates, face nail. <br />10d 0" x 0,128") <br />Sole plate to joist or blocking at <br />3-16d (3-1/2" x 0.135") <br />braced wall panels <br />Double top plates, minimum 24-Inch <br />offset of end joints, face nail in <br />lapped area <br />8-16d (3-1/2" x 0.135'") <br />24" D.C. <br />24" o.c, <br />16" o.c, <br />Blocking between joists or rafters to <br />3-8r1(2 1/2" x 0,113"} <br />tap plate, toe nail <br />Rim joist to top plate, toe nail <br />8d (2-1/2" x 0.113") <br />6" D.C. <br />Top plates, lapsat corners and <br />2-10d (3" x 0,128") <br />- <br />intersections, face nail <br />Built-up header; two pieces with <br />16d(3-1/2" x 0.135' 1 <br />„ <br />16 o.c, along each edge <br />1/2'" spacer <br />.... ..... <br />Continued header, two pieces <br />16d(3-1/2" x 0.135") <br />16" o.c. along each edge <br />Ceiling joists to plate, toe nail <br />3-8d (2-1/2' x 0.113") <br />- <br />Continuous header to stud, toe nail <br />4-8d (2-1/2" x 0.113") <br />Cellingioist, laps over partitions, <br />3-10d (3" x 0.128") <br />face nail <br />Ceiling joist to parallel rafters, face <br />.. ..... _.. <br />3-10d (3" x 0.128") <br />nail <br />Rafter to plate, toe nail <br />2-16d (3-1/2 x 0A35") <br />1" brace to each stub and plate, face <br />2 8d (2 1j2" x 0.113") <br />nail <br />V x 6'sheathing to each bearing, <br />2-8d (2-1/2" x OA13") <br />face nall <br />V x 8"sheathing to each bearing, <br />2 $d (2 1/2" x 0,113") <br />face nail <br />Wider than 1" x 8"sheathing to each <br />3-8d (2-1/2' x 0.113") <br />bearing, face nail <br />Built-up corner studs <br />10d (3" x 0.128") <br />24" o.c. <br />Built-up girders and beams, 2-inch <br />Nall each layer as follows: 32" o.c, <br />lumber layers <br />10d (3" x 0„128") <br />at top and bottom and staggered. <br />2" planks <br />2-16d (3-1/2" x G.135") <br />At each bearing <br />Roof rafters to ridge, valley or hip <br />rafters; <br />toe nail <br />face nail <br />4-16d (3-1/2" x 0.135") <br />3-16d (3-1/2" x 0.135") <br />- <br />Rafter ties to rafters, face nail <br />3-8d (2-1/2" x 0.113") <br />- <br />Collar tie to rafter, face nail, or 1- <br />3.-10d (3" x 0.128°) <br />- <br />1/4" x 20 gage ridge strap <br />Roof Sheating <br />8d R-1/2" x 0.113") <br />6"° O.C. Min. <br />4" O.C. Min. (End Zone) See WindDesign <br />Roof Sheeting <br />$d (2-1/2" x 0.113") <br />Roof Sheating <br />8d (2-1/2" x 0.113"} <br />4" O.C. Min, ( All corners) See wind <br />......_... <br />Design <br />Hoof Sheeting <br />8d (2-1/2" x 0.113") <br />4" O,C. Min. I@ All Gable ends) for <br />Length of 4'-0" perpendicular to end <br />A� �A7rAr �Ar A <br />Q <br />GABLE ROOF (PLAN VIEW) <br />WALTON <br />160 150 1 31-1 <br />4LYW <br />A r <br />Qi 0 i0 <br />-- --------------- <br />C <br />n <br />HIP ROOF (PLAN VIEW) <br />DIXIE <br />LEVY <br />/ <br />ZONE <br />OWIND <br />I <br />REF. TABLE ABOVE <br />5Oi <br />4 1 <br />I <br />® A <br />� <br />1 <br />I <br />I O I <br />END ZONE WIDTH <br />REF, WIND DESIGN <br />INFORMATION <br />ASCE 7-10 WIND DESIGN INFORMATION FOR LOW RISE BUILDINGS <br />BASIC WIND SPEED=140 MPH (3-SECOND GUST) (108 MPH NOMINAL) <br />RISK CATEGORY = It <br />EXPOSURE CATEGORY = B <br />Kd = 1.0 (Kd = 0.85 WHEN LOAD FACTORS ARE USED - ASCE TABLE 26.6-1) <br />KA = 1.0 <br />ENCLOSED BUILDING - INTERNAL PRESSURE COEFFICIENT + J - 0.18 <br />MEAN ROOF HEIGHT = < 30 FEET <br />ASCE 7-10 COMPONENT AND CLADDING WIND PRESSURE - FIGURE 30.5-1 <br />ROOF 7 TO 27 DEGREES <br />ROOF ZONE 1 = +20.3, 32.3 PSF <br />ROOF ZONE 2 = +203, -562 PSF <br />ROOF ZONE 3 = +20 3, -83.1 PSF <br />OVERHANG ZONE 2 = -65 7 PSF <br />OVERHANG ZONE 3 = -110.6 PSF <br />WALL ZONE 4 = +35.3 -38.2 PSF <br />WALL ZONE 5 = +35.3, -47.2 PSF <br />ZONE WIDTH - A = 3.0 FT , <br />OVERALL REPAIR PLAN <br />SCALE: 1/8" = V-0" <br />DUVAL <br />BAKER i <br />CLAY <br />AIACHUA PUTNAM <br />CITRUS <br />- SEMIN0 <br />HERNANDO � EKE ORANGE <br />MANATEE <br />POLK <br />DFSOTA IAKE <br />GLADES OKEECHO <br />AR <br />� HENDRY <br />DADE <br />..-... <br />180 <br />ALL WORK SHALL CoMpLY W1, � <br />CODES FLORIDA BUILDING CODE, <br />NATIONAL ELECTRIC CODE <br />AND THE CITY OF ZEP ' <br />N <br />o <br />U <br />C <br />' <br />c <br />Lo N <br />co iT <br />M C <br />o m N <br />o o <br />^d <br />N FL 'C <br />O <br />° <br />E <br />z Q <br />N Lo <br />Q N <br />r <br />IGHT ©2019rawings are forclusive use ofi Engineeringions, Inc. ande, are not to bed or reproducednner without thed written consent <br />wKUINANCEO HYRIiILLS of Florida Engineering <br />0 Solutions, Inc. <br />U <br />rn <br />c <br />m `111,``,1111//I/I <br />b"( is <br />0 °• 0) ®°+ <br />-I- <br />REVIEW DATE ° <br />�y p�I � _ <br />EW E 'UV 201 :w L() -F" CG• <br />CITY OF ZEPHYR o .�� ;c� �<c 0. <br />PLANEAMiNER �� ,� z k; <br />sj <br />c <br />c <br />E <br />REVISIONS <br />/l 10/31/19 <br />I <br />2 <br />A0 <br />o <br />A <br />E <br />0 <br />0 <br />Project Number: <br />0) <br />19 - 8581 - 999 <br />c <br />Check By: J.H. <br />m <br />Date: 08 / 09 / 19 <br />0) <br />a) <br />Drawn By: J.A. <br />rn <br />Date: 08 / 02 / 19 <br />at <br />0 <br />C <br />Y <br />E <br />O <br />a� <br />a) <br />s <br />1. 0 <br />